1. ON OFF Set the ON timer first Us Then set the OFF timer by the air conditioner starts opera y tion controlled with the ON timer earlier set OFF ON Set the OFF timer first Ge Then set the ON timer by the air conditioner stops opera eo tion controlled with the OFF timer earlier set The timer that is set later starts counting down after the counting down of the preceding timer is finished Note If you change the setting value for the timer after the program timer is set the counting down of the timer will be reset at that moment 1 SLEEP TIMER button Each time you press the button the time changes as follows gt 1 0 gt 2 0 gt 3 0 gt 5 0 gt 7 0 gt 9 0 hours CANCEL Set the time while the indicator on the remote controller display is blinking To repeat the timer press the button when the indicator is not displayed To help you to fall asleep comfortably and prevent excessive warming or cooling in sleep the SLEEP timer controls the temperature setting automatically in accordance with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode In COOL or DRY mode Set time Set temperature 1 a 2 F 1 C pe Set time Note for TIMER settings Any interruption of the power supply such as a blackout or cutting off of a circuit breaker makes the set internal clock go wrong In
2. Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit PART NO 9332621013 En 1 Indoor Unit Overview and Operations O Intake grille Before starting operation make sure that the intake grille has been shut completely Incomplete closing might have an effect on the proper working or performance of the product Manual AUTO button Use when you lost the remote controller or remote control malfunction occurs Status Action Mode or operation In operation Press more than 3 seconds Stop Stopping Press more than 3 seconds and AUTO less than 10 seconds Press more than 10 seconds Only for servicing Forced cooling After cleaning Press less than 3 seconds Filter indicator reset To stop forced cooling press this button or START STOP button on the remote controller Front panel Vertical airflow direction louver Each time you press SET button on the remote controller the angle of the vertical airflow direction louver moves as follows COOL or DRY mode HEAT mode 1 i 2 F 1 a E A 7 3 I 4 N Default setting in each mode S7 e Do not adjust by hand e At the beginning of AUTO or HEAT mode they may s
3. Q e Before cleaning the indoor unit be sure to turn it off and all the power supply has been disconnected e Before starting operation make sure that the intake grille has been shut completely Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner S e Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit e Do not expose the indoor unit to liquid insecticides or hair sprays Daily care Cleaning the air filters When cleaning the indoor unit body mind the following Mind that you have a periodical cleaning of the air filters to prevent e Do not use water hotter than 108 F 40 C reducing the operation efficiency of the product e Do not use scouring cleanser volatile solvents such as benzene or Using of clogged air filter with dust will lower the product performance thinner z f and may cause airflow reduction or increase of operating noise e Wipe the unit gently by using soft cloth Clean the air filters once every 2 weeks under normal use Cleaning the intake grille Pull up the handle of the filter in direction of the arrow and Open the intake grille in direction of the arrow While gently release the 2 claws I pressing the left and right mounting shafts of the intake grille Then pull the filter out with gently sliding it downward E3 outward I remove the intake grille
4. gt HEAT Notes in HEAT mode e At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes for preparation and then switches to the selected fan speed e Automatic defrosting operation overrides the heating operation when it is necessary SET TEMP temperature buttons Set desired temperature Temperature setting range AUTO 64 88 F 18 30 C COOL DRY 64 88 F 18 30 C HEAT 60 88 F 16 30 C Temperature control is not available in FAN mode FAN button xl Controls the fan speed w AUTO gt HIGH gt MED gt LOW gt QUIET e When AUTO is selected the fan speed is automatically adjusted according to the operation mode SET button Adjusts the vertical airflow direction SWING button T Starts or stops automatic swing of the vertical airflow direction louver e Each time you press the button the vertical airflow direction louver swings as follows COOL or DRY mode HEAT mode 12 2a 327 aaz ol 6227 Note SWING operation may stop temporarily when the fan in the unit is rotating at very low speed or stopping Q e If leaking battery fluid comes in contact with your skin eyes or mouth immediately rinse with plenty of clean water and consult your physician Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriat
5. in direction of the arrow EJ Remove dust by using a vacuum cleaner or by washing the filter When you wash the filter use neutral household detergent and warm water After rinse the filter well dry it throughly in a shaded place before you reinstall it Attach the air filter with aligning both side of the filter with the panel and push in the filter fully Wash the intake grille gently with water or wipe it gently with a Note soft cloth moisten with warm water Make sure that 2 claws are firmly snapped to the guide holes on Then wipe it with a dry and soft cloth the panel While holding the grille horizontal set the left and right mounting z shafts into the pillow blocks at the top of the panel To latch After extended non use of the unit each shaft properly insert the shaft until it snaps If you have shut down the indoor unit for 1 month or more perform the Then close the intake grille Ej FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In such a case the product inspection is recomm
6. performing following checks Symptom Diagnostic See page Does not operate at all O Has the circuit breaker been turned off O Has there been a power outage O Has a fuse blown out or the circuit breaker been tripped CO Is the timer operating Poor cooling or heating perfor mance O Is the air filter dirty O Is the intake grill or outlet port of indoor unit blocked O Is the room temperature adjusted appropriately O Is a window or door left opened O Is direct or strong sunlight shinning into the room in cooling operation C Are there other heating apparatus or computers operating or too many people in the room in cool ing operation O Is the fan speed set to QUIET The unit operates differently from the remote controller Oi Are the batteries used in the remote controller exhausted Oi Are the batteries used in the remote controller loaded properly setting Immediately stop operation and turn off the electrical breaker in following cases Then consult authorized service personnel e The problem persists even if you perform these checks or diagnostics e The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast Operating Range COOL DRY mode HEAT mode Outdoor temperature 15 to 115 F 10 to 46 C 15 to 75 F 10 to 24 C Indoor temperature 64 to 90 F 18 to 32 C 60 to 88 F 16 to 30 C I
7. such a case the TIMER indicator on the indoor unit blinks and you need to readjust the setting P F C button e Used for changing the temperature unit Initial setting F e When you press this button the displayed temperature unit switches to C and returns to F when you press it again e When you press this button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this figure y ah OF 3 ECONOMY button Starts or stops ECONOMY operation that saves more electricity consumption than the other operations with a conservative adjustment of the room temperature When you press the button the ECONOMY indicator on the indoor unit turns on e In COOL mode the room temperature will be adjusted at a few degree higher than the defined temperature In HEAT mode the room temperature will be adjusted at a few degree lower than the defined temperature e Especially in COOL mode you can have improved dehumidification without significantly lowering the room temperature Notes e In COOL or HEAT mode the maximum output of this operation is approximately 70 of usual air conditioning operation e This operation cannot be performed during temperature monitoring by AUTO mode OPERATING MANUAL POWERFUL button Starts POWERFUL operation that enables quick cooling down or warming up of the room When you press the button to start the P
8. unit Absorbed room smell generated from interior textile furniture or cigarette smoke into the air condi tioner may be emitted Mist or steam is emitted from the unit In COOL or DRY mode a thin mist generated by condensation formed with sudden cooling process may be emitted During heating operation the fan built in the outdoor unit may stops and rising steam generated by the automatic defrosting operation may be seen Airflow is weak or stops e Immediately after the heating operation is started the fan speed stays temporarily very low to warm up the internal parts of the unit e In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor unit may emit water generated by the automatic defrosting operation Before you call for or request ser vicing troubleshoot a problem by
9. AIR CONDITIONER Wall Mounted Type OPERATING MANUAL Contents Safety Precautions Indoor Unit Overview and Operations Valcyon Y THE POWER TO CALM THE WIND CO FUJITSU Frangais Remote Controller Overview and Operations Care and Cleaning Troubleshooting Operating Range Indoor Unit Outdoor Unit ASVGO9LLCA AOVGO9LLCA Before using this product read these instructions ASVG12LLCA AOVG12LLCA thoroughly and keep this manual for future reference Safety Precautions To prevent personal injury injury to others or property damage read this section carefully before you use this product and be sure to comply following safety precautions Incorrect operation due to failure to follow the instructions may cause harm or damage the seriousness of which is classified as follows Z N WARNING This mark warns of death or serious injury S This mark denotes an action that is PROHIBITED N WARNING e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This unit contains no user serviceable parts Always consult authorized service personnel for repairing installa
10. COOLING OPERATION Push for more than 10 seconds See page 5 Easy to care air filters resist mildew growth Indoor unit accessories S 90g Remote controller Batteries Tapping screw Remote controller M3x12 mm holder Z N WARNING Take care to prevent infants and small children from acciden tally swallowing the batteries Battery AAA R03 LRO03 x 2 loading e Use specified type of battery only e Do not use new battery and used battery together e Batteries can be used about 1 year in ordinary use e If the remote control range noticeably got shorten replace the batteries and press RESET button AIR CONDITIONER Wall Mounted Type Remote Controller Overview and Operations Z N caution Q e To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Exhausted batteries must be removed immediately and be disposed according to the local laws and regulations of your region Remote controller holder installation Slide up You can quickly start the operation with following 3 steps START STOP button MODE button Switches operation mode in following order i AUTO gt COOL gt DRY gt FAN
11. OWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finishing the POWERFUL operation mode setting It is not turned off automatically during setting of the POWERFUL operation Notes The airflow direction and the fan speed are controlled automatically e This operation cannot be performed simultaneously with ECONOMY operation To return to normal operation press the button again Then the indoor unit emits 2 short beeps 5 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting Signal transmitter Aim to signal receiver of the indoor unit properly e Signal transmit indicator 4 on the remote controller display shows that signal from the remote controller is being transmitted Operating range is approximately 7 m e You will hear a beep if the transmitted signal has been sent properly If there is no beep press the button on the remote controller again Automatic defrosting operation When outdoor temperature is very low with high humidity frost may form on the outdoor unit during the heating operation and it could reduc
12. e signal transmission S e Do not apply strong shocks to the remote controller e Do not pour water on the remote controller e Do not attempt to recharge dry batteries INVERTER Y C SWING O START STOP K4 6 RESET I T TIMER ODSLEEP COFF t CAET RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this figure wll SV 8 TIMER CANCEL button Cancels the set timer ON TIMER button Each time you press the button the time changes as follows 0 5 gt 1 0 1 5 gt 2 0 gt gt 9 0 gt 9 5 10 11 gt 12 Z hours Set the time while the indicator on the remote controller display is blinking OFF TIMER button T Each time you press the button the time changes as follows 0 5 gt 1 0 gt 1 5 gt 2 0 gt Z hours gt 9 0 gt 9 5 ee hours e Set the time while the indicator on the remote controller display is blinking k The setting must be done within about 3 seconds during the indi cator stays solid The button is controllable only when the air conditioner is on continued OPERATING MANUAL En 3 En 4 Remote Controller Overview and Operations Program timer combined use of the ON timer and the OFF timer You can set an integrated ON OFF or OFF ON timer as follows
13. e the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the heating operation the outdoor unit will stop automatically after it operates for a few minutes Then the automatic defrosting operation starts Auto restart function In event of power interruption such as a blackout the air conditioner stops once But it restarts automatically and performs previous operation when the power supply is resumed If any power interruption occurs after the timer is set counting down of the timer will be reset After the power supply is resumed the TIMER indicator on the indoor unit blinks to notify you that there has been a timer fault In such a case reset the timer for your opportune time Malfunctions caused by other electrical devices Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller AIR CONDITIONER Wall Mounted Type Care and Cleaning Z CAUTION
14. ended For more information consult authorized service personnel OPERATING MANUAL En 5 Troubleshooting ZN WARNING In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult authorized service personnel As long as the unit is connected to the power supply it is not insulated from the power supply even if the unit is turned off Following symptoms do not indicate the product malfunction but they are normal functions or characteristics of this product Symptom Cause See page Operation is delayed after restart To prevent blowout of the fuse the compressor will not operate during the protection circuit is working for about 3 minutes after sudden OFF ON operation of the power supply Noise is heard e During the operation or immediately after stopping the air conditioner refrigerant flowing sound may be heard And it is particularly noticeable for 2 3 minutes after starting operation e During the operation a slight squeaking sound produced by the minute expansion and contraction of the front panel caused by temperature change may be heard During heating operation a sizzling sound produced by the automatic defrosting operation may be heard Smell coming from the
15. ndoor humidity 80 or less En 6 OPERATING MANUAL
16. tay position 1 for a while for adjustment e If you set the angle to position 5 7 for more than 30 minutes in COOL or DRY mode they automatically return to position 4 In COOL or DRY mode if the angle is set to position 5 7 for many hours condensation may be formed and the drips may wet your property Drain hose Remote control signal receiver Z N CAUTION For appropriate signal transmission between remote controller and Q the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased the product T ECONOMY indicator green Lights in ECONOMY operation TIMER indicator orange Lights in TIMER operation and blinks slowly when the timer setting error is detected As for the timer setting error refer to Auto restart function on page 4 OPERATION indicator green Lights in normal operation and blinks slowly in automatic defrosting operation Horizontal airflow direction louvers Z N CAUTION 2 Before you adjust the horizontal airflow direction make sure that the vertical airflow direction louver has been stopped completely Adjust two knobs by hand En 2 OPERATING MANUAL MANUAL AUTO Push for more than 3 seconds FORCED
17. tion and relocation of this product Improper installation or handling will cause leakage electric shock or fire In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should only be replaced by authorized service personnel 9S Z N CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit Unplug the power supply cable when not using the indoor unit for an extended period After long period of use check whether the installation stand does not deteriorate to prevent the unit from falling down The airflow direction and the room temperature should be carefully considered when you use this product in a room with infants children elderly or sick persons e Do not direct the airflow at fireplaces or heating apparatus e Do not block or cover the intake grille and the outlet port e Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from the unit FUJITSU GENERAL LIMITED 1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan N CAUTION This mark warns of inj
18. ury or damage to property Q This mark denotes an action that is COMPULSORY e In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel e If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands Do not place vase or water container on the unit Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the unit directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items