1. diameter 17 mm intermediate base rated 120 V 40 W or below Assembly Replace the front cover with 4 screws CAUTION To prevent the screw holes from being damaged be sure to tighten the screws with the torque of 13 inch Ibs 1 5 N m or less Check 1 Turn on the electrical circuit to the range hood 2 Make sure that the switch and light operate correctly Refer to page 4 of the Operation Manual 3 Check the ventilating functions at Hi Me and Lo positions 4 Make sure that the range hood has no abnormal noises and or vibration OFF Me Hi LIGHT CAUTION e To reduce the risk of injury keep your hands and other objects away from the fan while it is in motion e Wear working gloves to avoid injury 12 INSTALLATION continued APLANATION TU IF NL m 1 Refer to the Operation Manual explain the operation of this range hood to end users 2 The Installation Manual and Operation Manual should be given to the end user CIRCUIT DIAGRAM 120V 60Hz 04 gt 0 Motor Green Terminal White Black Connector ZN kvm NE Red x White Orange Brown Red Blue Eg _ Lg c 2 x o L is 2 9 8 malol S 0 6 Bulb Max40W Connector 13 FUNOH Fuji Industrial USA Inc 16300 Christensen Rd Ste 212 Seattle WA 98188 3403 Telephone 1 888 547 9880 1U030584
2. 6 et Range hoodunit Duct Liner Wy INSTALLATION continued Hold up the range hood unit and insert it into the opening of the liner When the 4 securing plates on both sides have passed through the top of the liner turn them outward to secure the range hood on the liner temporarily Make sure that the top of the exhaust pipe is inserted into the bottom of the transition duct J Transition duct Securing plate Range hood unit each side two lt 2 places f Liner Front cover Securing plate Securing plate turns while passing through the opening of Liner INSTALLATION continued Remove 4 screws which are fixed to the front cover The front cover swings open 90 as shown in Fig CAUTION Do not detach the front cover from the range hood unit The hinge may be damaged Front cover Four 4 N fixing Front cover screws Align 4 screw holes of the liner and range hood unit then fix securely using the supplied screws and nuts NOTE Fasten all screws and nuts evenly Nut with plate Right amp left Range hood unit each two 2 places Liner Four 4 screws Make the duct joint secure and air tight Fn cic using non flammable tape such as duct tape etc not supplied Lue NOTE Make sure that the shutter installed in the exhaust pipe moves freely Range hood unit Duct tape etc 10 INSTALLATION continued JNN NG POV B ad a NIF N WAR
3. FUJIOH Installation Manual RANGE HOOD MODEL BUF 01 BUF 02 TABLE OF CONTENTS Safety LEG HONS EEE EN 2 VET Or OE eee eee eer ee ere en ere eee ene te 4 Ze DES BP 4 Range Hood LOCAUON EE EE EE ER 5 MSTO EE EE EE S E E EE 6 VPN sesini ei EEE A EE A E E nee esi anes ewes anaes 6 2 Range Hood MOUNINO s cecencietetrcaies teinders spun ttwtncdinccictodduesndanteus tess cdeeiwidalboamentaue don 8 3 Connecting Power Supply Wires cccccseccccseeeeccseseeeceeeeeseuseesseeeessaeeeeees 10 4 Final Assembly and Check cccccseccecseeeecceeeeeecaeceeseeeeesseeeeesagseeesageessaees 12 5 Explanation to the End User icceccccscvensvcdeesemscadessiseestewstiethcadedend smeden deivninpder 13 CUN DIA EE Measauneaisisaest toaaandos 13 READ AND SAVE THESE INSTRUCTIONS Keep this manual in a convenient place for future reference FUJI INDUSTRIAL CO LTD 1U030584 SAFETY INSTRUCTIONS Before installation and operation read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual The signal words shown below are used to alert you to potential personal injury and property damage hazards There are three hazard classifications based on potentially dangerous situations Obey all safety instructions that show these symbols to avoid possible injury death and property damage A WARNING WARNING indicates a potentially hazardous situation which if not avoide
4. NING e Electrical wiring should be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction An unqualified person doing the work could result in fire electric shock or injury e This range hood uses 120V AG Do not connect to other voltage since fire electric shock or damage could result Remove the nut from the conduit An connector at the end of power wiring WARNING Be sure to switch power OFF at service panel ve before wiring aan Nut Remove one screw fixing the wire cover and detach it Wire box lll er ZA i ul V gt Wire cover One 1 screw Connect the conduit through the connecting hole of the body using the nut previously removed Wire box INSTALLATION continued Connect the electrical wires as follows Connect wires tightly and securely using wire connectors not supplied e Black to Black e White to White e Green to Green Conduit Wire box l Wire connector Wires Not supplied unit side Wires conduit side Replace the wire cover with the screw removed previously Make sure that all wires are connected properly and enclosed inside of the wiring compartment l Conduit Wire box Wire cover 11 INSTALLATION continued 4 FINAL ASSEMBLY AND CHECK One 40 W light bulb not supplied can be mounted to this range hood Prior to final assembly install a light bulb ordinary type in the base
5. UND DUCT For vertical discharge discharge upward For vertical discharge run duct work between the hood location and roof cap location To get the best result use a minimum number of transitions and elbows Be sure to attach a roof cap to avoid leaking SOFFIT rain in the end This range hood is designed to SAPS I F III AX LAL SS BAN SASAANADSSASSNSNANS SS XXX DOOD S S ve 2 RANGE HOOD NAS RE NAN SS The range hood unit must be mounted to a liner which has the following dimensions Install the liner securely after checking that the opening size of the liner is the same as the figure below 18 11 16 ee 17 3 8 1 16 11 11 16 CAUTION The liner should be installed tightly If the liner installation is not correct the range hood unit may become detached and fall INSTALLATION continued Run house wiring between service panel and hood location Prepare the range hood unit 1 The range hood is supplied with the Exhaust pipe exhaust pipe fixed on its top plate 2 Provide a transition duct not supplied to connect the exhaust YY pipe and external duct The JJ diameter of the transition duct Jf ll should be more than 6 YAY ALY NE MY A A A 5 3 16 3 Be sure to keep 1 3 16 overlapping length of the exhaust pipe and transition duct Jf J Transition Duct Not supplied 1 3 1
6. d could result in death or serious injury A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage N WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel To reduce the risk of fire or electric shock do not use this product with any solid state speed control device TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those publi
7. od may injure you or damage itself NOTE The safety instructions are explained with the following pictographic symbols Q means prohibition It indicates actions if any that mustn t be done means forcible execution It indicates actions if any that must be done NAME OF PARTS Enclosure Lamp cover Front cover Accessories ap 4 an z Jed Z Screw M5x30 SIZE amp DIMENSIONS 11 7 16 N NS I N 19 11 16 13 11 16 gt Unit inch RANGE HOOD LOCATION The range hood must be installed just above the cooktop The minimum distance from the cooking surface to the bottom of the range hood must be 24 BUF 01 BUF 02 18 lbs 8 kg The total weight of the BUF 01 BUF 02 range hood unit is Power requirements are BUF 01 AC120V 60 Hz 1 3 Amp BUF 02 AC120V 60 Hz 2 Amp Liner 24 minimum Zz 0 S amp S Zz 8 S amp S Cook top ip CAUTION e Check that the hood is correctly installed since incorrect installation could result in the detachment of the range hood and the unit fall e To protect hands from injury wear working gloves when installing the range hood INSTALLATION N WARNING e If the range hood is not installed properly it could become detached and fall e Ensure that the metal duct does not touch other metal housing materials otherwise fire or electric shock could result ROOF CAP 6 RO
8. shed by the National Fire Protection Association NFPA and The American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fan must always be vented to outdoors TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK This unit must be grounded Install this range hood to a liner Check that the hood is correctly installed since incorrect installation could result in the range hood becoming detached and falling off Connect only to an AC 120 Volt power source or the range hood could result in fire electric shock and damage CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls ceilings or into attics crawl spaces or garages Read specification label on this product for further information and requirements Use only for the purpose of kitchen ventilation Do not install this range hood in the bathroom or in other wet rooms since electrical shock and damage may result Fasten the filter and other parts securely Incorrect attachment may result in personal injury or property damage Keep your hands and other objects away from the fan while it is in motion The range ho