Home
Frigidaire FFGC3005LW Product Specifications Sheet
Contents
1. FRIGIDAIRE Drop In Cooktop FFGC3005L W 30 Gas Product Dimensions Width 30 Depth 21 1 2 Height 3 1 8 More Easy To Use Features Easy Clean Lift Up Cooktop Available in White w Burners BTU Right Front 9 000 Right Rear 9 000 Left Front 9 000 Left Rear 9 000 Signature Features Ready Select Controls Color Coordinated Select options or control cooking temperature Control Knobs with our easy to use controls White cooktops come with matching knobs Electronic Pilotless Ignition Porcelain Cooktop Grates Saves energy and can be ignited manually Grates are durable and easy to clean when electricity is out frigidaire com FRIGIDAIRE Features Controls Surface Type Grates Right Front Element BTU Right Rear Element BTU Left Front Element BTU Left Rear Element BTU Control Location Knob Color Knob Type Bowl Type Specifications Power Supply Connection Location Gas Supply Connection Location Voltage Rating Connected Load kW Rating 120 Volts Amps 120 Volts Minimum Circuit Required Amps Approved for Electric Single Wall Oven Combination Installation Shipping Weight Approx Ready Select Color Coordinated Porcelain Steel Round with Black Gloss Finish 9 000 9 000 9 000 9 000 Right Side White Plastic Right Rear Right Rear 120V 60V 15A 8 1 0 15 35 Lbs For use on adequately wired 120V dedic
2. 800 265 8352 frigidaire ca FFGC3OO5L 10 12 Allow 30 minimum clearance between top of cooktop platform and bottom of unprotected wood or metal overhead cabinet Allow 2 minimum distance between rear edge of cooktop and adjacent combustible surface or backsplash e Allow 2 minimum required clearance from left edge of cooktop to adjacent combustible surface and O minimum from right edge of cooktop to adjacent combustible surface e To reduce risk of fire when using overhead cabinetry install range hood that projects horizontally a recommended minimum of 5 beyond bottom of cabinets Gas Drop In Cooktop model FFGC3005L is NOT approved to be used over any Frigidaire Single Wall Oven Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Optional Accessories e Granite Countertop Installation Kit PN 903103 9010 Accessories information available on the web at frigidaire com ASTE O A aie NETA A Specifications subject to change 2012 Electrolux Home Products Inc FRIGIDAIRE For all approved gas cooktop models a minimum height opening of 6 1 2 from top of counter required in right side filler panel to route gas and electric hookups Refer to Gas Cooktop Utility Hookup Diagram Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate depth of approved
3. RIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca GC_EW INST FR 11 13 120V 60Hz grounded outlet for gas cooktop Unit will overlap cutout minimum edges by 1 Critical dimension MUST be applied For cooktop cutout dimensions refer to model specific product page or installation guide on web Gas Cooktop Installation Over 30 27 Electric Single Wall Oven lt 18 max gt J Countertop Gas Cooktop Utility Hookup Flexible connector Flare union 120V 60Hz N grounded outlet Manual shutoff valve Must be accessible Pressure regulator Cabinet sides and or filler panel Side View Oven cutout 27 1 4 min 28 Ys max 1 I i Wall Oven H Install 3 4 full plywood base on 2 runners flush with toe plate capable of supporting 200 Ibs 30 models or 150 Ibs 27 models Cutout Width A To route armored cable to junction box 30 Wall 28 2 min cut minimum 4 x 4 opening in wood base 2 from left side filler panel Oven 29 max 27 Wall 24 7 min Oven 251 max t This installation drawing excludes model GLEB27Z7H with side swing door Gas Cooktop Installation Over 30 27 Electric Single Wall Oven Specifications All Frigidaire Electric Single Wall Ovens are approv
4. arance for oven rack removal e Side filler panels necessary to isolate oven from adjoining cabinets e Oven base of solid plywood or similar material required capable of supporting 150 Lbs Install over two runners and flush with toe plate e Base must be level and cabinet front must be square Recommended that bottom of cabinet remain partially opened to permit free air circulation avoiding possible water condensation which may appear inside control panel while operating oven Allow 5 maximum height from oven base to floor if NO cooktop is installed directly over wall oven FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca GC_EW_SS INST FR 11 13 2013 Electrolux Home Products Inc Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Specifications subject to change
5. ate depth of approved Flexible connector gas cooktop models Pressure regulator Electric Single Wall Oven Cutout For 27 model GLEB27Z7H with side swing door angor tiller p Cooktop 231 25 Vs max Cabinet sides Oven cutout Gas Cooktop Utility Hookup Flare o Fia en 120V 60Hz grounded outlet Manual shutoff valve anel Must be accessible Side View I 1 i i Approx 3 L Plywood min a 28 min oov T o A 28 max Junction box O oe eeze8 i Wall Oven for wall oven ip L 2474 miN i ls 24 min Install 3 4 plywood base on 2 runners flush with cutout depth toe plate capable of supporting 150 Ibs Minimum 4 2 distance required from door hinge side of oven s cutout opening to ie any adjoining cabinetry or wall to allow sufficient clearance for oven rack removal 4 1 2 maximum height allowed ae o from oven base to floor if cooktop To route armored cable to junction box cut minimum is installed directly over wall oven 4 x 4 opening in wood base 2 from left side filler panel C ro moliap ohtallowed Critical dimension MUST be applied Note Recommended that bottom of cabinet i For cooktop cutout dimensions remain partially opened to permit free air circulation refer to model specific product page avoiding possible water condensation which may or installa
6. ated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation FRIGIDAIRE Drop In Cooktop FFGC3005L W 30 Gas NOTE Always consult local and national electric and gas codes Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire com Product Dimensions A Width B Depth C Height USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca FFGC3005L 10 12 2012 Electrolux Home Products Inc 30 21 1 2 3 1 8 Cutout Dimensions Width Min Width Max Depth Min Depth Max Height 26 5 8 26 7 8 19 19 3 8 8 1 8 Granite Countertop Installation Kit available Accessories information available on the web at frigidaire com Specifications subject to change Drop In Cooktop FFGC3005L W 30 Gas FRIGIDAIRE unprotected cabinet Includes clearance needed beneath cooktop to allow for gas supply Opening to route 48 connection power cable amp gas supply if base is present G min between rear edge of cooktop and adjacent l r combustible surface or backsplash 1 min required from right edge of seo cooktop to adjacent combustible J min from surface edge of cutout to front H min required edge of countertop from l
7. ed to be used beneath any approved Frigidaire Gas Cooktop This installation page excludes approved wall oven model GLEB27Z7H For model specific installation details refer to Gas Cooktop Installation Over 27 Electric Single Wall Oven GLEB27Z7H Specifications pages on web For detailed Gas Cooktop installation refer to model specific product page and installation guide on web Side filler panel height may need to be modified to accommodate the depth of approved gas cooktop models Minimum height opening of 6 1 2 from top of counter required in right side filler panel to route gas and electric hookups Allow 4 1 2 maximum height from oven base to floor if cooktop is installed directly over wall oven Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Specifications subject to change 2013 Electrolux Home Products Inc FRIGIDAIRE Gas Cooktop Installation Over 27 Electric Sing For all approved gas cooktop models a minimum height opening of 6 1 2 from top of counter required in right side y o9y gqHz le Wall Oven GLEB27Z7H lt 18 max gt Counterto 3 p filler panel to route gas and electric hookups Refer to grounded Gas Cooktop Utility Hookup Diagram outlet for gas cooktop Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommod
8. eft edge of cooktop to adjacent combustible surface Product Dimensions Required Clearances Product Cutout Dimensions K Cabinet Opening Width Utility Connection Locations E Depth min max F Height min min Power Supply Gas Supply D Width min max 26 5 8 26 7 8 19 19 3 8 8 1 8 Drop In Cooktop Specifications Product Shipping Weight approx 35 Lbs Voltage Rating 120V 60 Hz 15 Amps For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded or safe operation Amps 120 Volts 1 0 Amps Always consult local and national electric and gas codes e Cooktop cutout height includes clearance needed beneath cooktop o allow for gas supply connection Recommended location for grounded 120V outlet is on rear wall in an 8 wide by 10 high area positioned 22 above floor surface and 4 from right side of cooktop centerline Access to underside of cooktop and junction box must be provided for inspection and service Cooktop ships with 3 4 factory regulator e Natural gas only e Overhead cabinetry should not exceed a 13 maximum depth e Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 30 FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1
9. gas cooktop models Electric Single Wall Oven Cutout For all 30 amp 27 modelst eo 232 ANC k Plywood min sa 240 208V bases z747 Junction box A 10 for wall ng 24 min cutout depth 4 1 2 maximum height allowed from oven base to floor if cooktop is installed directly over wall oven 5 maximum height allowed with no cooktop 30 27 Electric Single Wall Oven Under Counter Installation Specifications e Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit used on both sides of line For detailed electrical requirements refer to model specific product page and installation guide on web Always consult local and national electric codes inimum 21 clearance for oven door depth when open inimum 23 1 2 deep cutout dimension is critical for proper installation to ensure that oven s faceplate will fit flush against cabinet front Side filler panels necessary to isolate oven from adjoining cabinets Full oven base of solid plywood or similar material required capable of supporting 200 Lbs 30 models or 150 Lbs 27 models nstall over two runners and flush with toe plate e Base must be level and cabinet front must be square Allow 5 maximum height from oven base to floor if NO cooktop is installed directly over wall oven FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 F
10. tion guide on web appear inside control panel while operating oven 27 Electric Single Wall Oven GLEB27Z7H Gas Cooktop Installation Over Under Counter Installation Specifications 27 Electric Single Wall Oven GLEB27Z7H Specifications Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz Frigidaire Single Wall Oven model GLEB27Z7H is approved to be used AC only electrical supply with ground required on separate circuit beneath any approved Frigidaire Gas Cooktop used on both sides of line For detailed Gas Cooktop installation refer to model specific product e For detailed electrical requirements refer to model specific product page and installation guide on web page and installation guide on web Side filler panel height may need to be modified to accommodate the e Always consult local and national electric codes depth of approved gas cooktop models e Minimum 27 1 4 clearance for oven door depth when open Minimum height opening of 6 1 2 from top of counter required in Minimum 23 1 2 deep cutout dimension is critical for proper right side filler panel to route gas and electric hookups installation to ensure that oven s faceplate will fit flush against Allow 4 1 2 maximum height from oven base to floor if cooktop is cabinet front installed directly over wall oven inimum 4 1 2 distance required from door hinge side of oven s cutout opening to any adjoining cabinetry or wall to allow sufficient cle
Download Pdf Manuals
Related Search
Related Contents
XV-Z3300 VX1000 - Podium Pro Z8 DMX-512 LED CONTROLLER User Manual rel SS2 PS3 v - SQUARE ENIX Support Center Mushroom - CHAUVET® Lighting 8500950 XT1121-000 User`s Manual Audiovox ACD-28 Car Stereo System User Manual Frigidaire FGBD2434PB Product Specifications Sheet Páginas del menú Ayuda 事 務 連 絡 - 福島県薬事工業協会 Copyright © All rights reserved.