1. FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 e San Antonio Texas 78295 1540 210 357 4400 e FAX 210 357 4480 VERT I PAK SINGLE PACKAGE VERTICAL AIR CONDITIONERS LIMITED WARRANTY A ONE YEAR WARRANTY FRIEDRICH AIR CONDITIONING CO FRIEDRICH warrants to the original end user of this product that should it prove defective due to improper workmanship and or material under normal use for a period of one year from the date of installation FRIEDRICH will repair or replace at its option any defective part without charge for the part Replacement parts are warranted for the remainder of the original warranty period THIS WARRANTY DOES NOT INCLUDE LABOR or other cost incurred for servicing repairing removing installing shipping or handling of either defective or replacement parts or complete unit Such cost may be covered by a separate warranty provided by the installing contractor EXTENDED FOUR YEAR COMPRESSOR WARRANTY During the second through fifth year from the date of installation should the compressor prove defective due to improper workmanship and or material FRIEDRICH will furnish a replacement compressor at no charge which is warranted for the remainder of the original warranty period LABOR IS NOT INCLUDED FOR INSTALLING REPLACEMENT COMPRESSOR D NOTICE To obtain service and or warranty parts replacement you must notify an authorized FRIEDRICH Air Condition ing Co distributor dealer or contractor of an
2. 00 Bracket Bellows DO OINI OLA alya yalya a El BR B B O O N N N afa 800 228 01 Bracket Bellows 210 590 23 Suction Freeze Protection Device 210 585 68 Check Valve 210 585 67 Check Valve 650 135 00 Check Valve 605 420 03 Fan Plastic 13 605 420 04 Fan Plastic 14 5 617 769 00 Motor Mount Asy 800 067 02 Riser Motor Mount 800 067 01 Riser Motor Mount 800 068 041 Motor 1 4 1 6p CCW 618 049 00 Shroud Medium 618 036 01 Shroud Small 800 170 00 Heater 2 5 KW 230V 800 170 041 Heater 3 4 KW 230V 800 170 02 Heater 5 0 KW 230V 250 111 00 Defrost Thermostat 210 584 07 Limit Switch 2 5 Kw Heater 210 584 08 Limit Switch 3 4 Kw Heater 210 584 09 Limit Switch 5 0 Kw Heater 606 106 05 Wheel Blower 606 106 10 Wheel Blower 610 805 38 Capacitor 25 10 MF 370V 610 805 68 Capacitor 25 10 MF 440V 600 840 33 Relay 24V SPST See Notes Heat Pump 4 210 568 99 Transformer 800 076 00 Non Fused Disconnect 250 432 01 Terminal Block 800 103 03 Wrapper Assy Insulated 800 103 02 Wrapper Assy Insulated 210 586 43 Coil Solenoid Rev Valve 250 182 01 Reversing Valve 250 183 01 Reversing Valve 250 187 01 N S Not Shown Reversing Valve Friedrich
3. CTION WITH THIS PRODUCT WHETHER ARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of Incidental special or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and provinces to provinces Use Factory Certified Parts FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com Printed in the U S A VPPMO3G 11 02 DM
4. Parts Manual VERELPAK Single Package Vertical Air Conditioning System G Suffix Models MODELS V E H A09K25 G V E H A09K34 G V E H A09K50 G V E H A12K25 G V E H A12K34 G V E H A12K50 G V E H A18K25 G V E H A18K34 G V E H A18K25 G VPPMO3G 11 02 Digits vary with model VELLPAK Model Number Identification Guide MODEL NUMBER V ETTA 109 K 50 RT G Suffix SERIES V Vertical Series E Cooling with or without electric heat ENGINEERING CODE H Heat Pump CONTROL DESIGN SERIES RT Remote Thermostat SP Seacoast Protected NOMINAL CAPACITY 09 9 000 Btuh 12 12 000 Brun 18 18 000 Btuh ELECTRIC HEATER SIZE Nominal KW size 00 no elect heat 25 2 5KW 34 3 4KW 50 5 0KW VOLTAGE K 208 230V 1Ph 60Hz VEREEPAK Serial Number Identification Guide SERIAL NUMBER L B A V 00001 DECADE MANUFACTURED PRODUCTION RUN NUMBER he l SE PRODUCT LINE R RAC YEAR MANUFACTURED P PTAC J 9 E EAC K 0 V VPAK H SPLIT MONTH MANUFACTURED A Jan D Apr G Jul K Oct B Feb E May H Aug L Nov C Mar F Jun J Sep M Dec This document reflected an accurate listing of parts and information at the time of its publication Our policy of continuously upgrading and improving our products makes it impossible to keep it up to date Your Friedrich dealer his supplier and the Customer Service Department at Friedrich will have the la
5. here containing chlorine fluorine or any other damaging chemicals c modification alter ation poor service practices d improper matching or application of the product or components e failure to provide proper maintenance and service to the product according to manufacture s instructions f installation or operating of the product in a manner contrary to the instructions of the manufacturer g lightning fluctuations in electrical power or other Acts of God This LIMITED WARRANTY also excludes all cost of installation disconnection or dismantling the product parts used in connection with normal maintenance such as air filters or belts and owner required maintenance Consult the instructions enclosed with the product for information regarding recommended maintenance No one is authorized to change this LIMITED WARRANTY in any respect or to create any other obligation or liability in connection with this product YOUR ONLY REMEDIES ARE PROVIDED IN THIS LIMITED WARRANTY ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW IS HEREBY EXCLUDED AND DISCLAIMED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FORANY PARTICULAR PURPOSE ARE EXPRESSLY LIMITED TOA TERM OF ONE YEAR FROM THE DATE OF ORIGINAL INSTALLATION UNDER NO CIRCUMSTANCES SHALL FRIEDRICH BE LIABLE TO THE OWNER ORANY OTHER PERSON FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES IN CONNE
6. test information should problems arise Please contact us ERT I PAK Electrical Component Layout 8388858 1 1 Quick Disconnect ea 16 o ie l 2 Capacitor l ST 5 6 7 8 3 Defrost Thermostat ET gt Eh ba do f 4 Transformer e i el x z iz z x 5 Cool Relay 21 ES E S 6 Fan Relay lt 7 Heat 1 Relay Electric Strip 8 Heat 2 Reversing Valve 9 Electric Strip Heater 10 Thermostat Terminal Block ERT I PAK Components 7 8 Part Description 250 249 08 Compressor 250 249 07 Compressor 250 249 06 Compressor 617 645 35 Overload 617 645 21 Overload 617 645 22 Overload 618 501 07 Indoor Coil Assy 618 500 10 Indoor Coil Assy 618 503 17 Outdoor Coil Assy 618 502 18 Outdoor Coil Assy 618 503 18 Outdoor Coil Assy See notes Sea Coast 618 502 19 Outdoor Coil Assy See notes Sea Coast 037 605 11 Tube Capillary Cooling Heat Pump 013 899 03 Tube Capillary Cooling Heat Pump 037 605 18 Tube Capillary Heating Heat Pump 037 605 20 Tube Capillary Heating Heat Pump 013 902 23 Tube Capillary Heating Heat Pump 013 899 03 Tube Capillary Cooling Electric Heat 800 237 00 Base pan 601 799 00 Bellows Condensate Valve 800 228
7. y defect within the applicable warranty period Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part You must present proof of the original date of installation of the product in order to establish the effective date of the warranty Otherwise the effective date will be deemed to be the date of manufacture plus thirty days The return of the owner registration card is not a condition of warranty coverage However please detach and return it so that we can contact you should a question of safety arise which could affect you TO OBTAIN WARRANTY SERVICE please contact your authorized FRIEDRICH distributor dealer or the contractor who installed the equipment If your dealer or contractor needs assistance the authorized FRIEDRICH distributor is available for consultation and FRIEDRICH supports the efforts of the distributor This limited warranty applies only to units remaining at the site of the original installation except for mobile home installa tions and only to units installed within the continental United States Alaska Hawaii and Canada This limited warranty applies only if the unit is installed and operated in accordance with FRIEDRICH instructions and in compliance with appli cable local installation and building codes and good trade practices THIS WARRANTY DOES NOT COVER damages caused by a accident abuse negligence or misuse b operating the product in a corrosive atmosp
Download Pdf Manuals
Related Search
Related Contents
technisches Datenblatt zum User manual for BeSafe iZi Kid X1 i-size-GB FILTROSTABIL 取 扱 説 明 書 家取扱説明書宝 - 東芝ライテック Fluke 192/196/199 Apparatus for the display of embedded information Red Hat Enterprise Linux 6 Developer Guide To Remove 3 Point Seat Belt and Seat Pad • Pour retirer la ceinture Asko T721 Electric Dryer Copyright © All rights reserved.