1. press the or button 12 SELECTING FILTER MODE After installation the VentSurface has to be set to operate on aluminium mesh filter mode if the extracted air is ducted outside or carbon filter mode if the extracted air is recirculated indoors To change between filter modes 1 Make sure the VentSurface is on stand by plugged into a power outlet which is switched on but the fan is off 2 Press the button 3a The display will show the OR 3b The display will show the C symbol indicating that the VentSurface is set to carbon filter mode internal recirculation 4 Press the button and hold down for at least five seconds to change to the filter mode you want The filter mode last selected will be activated eu symbol indicating that the VentSurface is set to aluminium mesh filter mode external ducting 2 2 2 599489D izona vsisland install A2 NZGB indd 21 7 09 2 52 11 PM 13 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Have you used the correct fixing screws Have you used the wall anchors provided Have you used the washers provided Have you made sure that all standard requirements for ducting recirculation and electrical connection are met Is the VentSurface set for the correct cooktop type and filter mode d UUUL lt Is there a means of disconnection from the mains electricity supply disconnection switch or power outlet accessible to the customer after installation Have
2. 1 1 1 599489D izona vsisland install A2 NZGB indd 21 7 09 2 51 59 PM Installation instructions IZONA VentSurface HI120 ISLAND models Fisher amp Paykel innovative living Important SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our local website listed at the end of this document or contact your local Fisher amp Paykel dealer SAFETY AND WARNINGS A WARNING Electrical shock hazard Always disconnect the appliance from the mains electricity supply before carrying out any servicing or maintenance operations Failure to do so could result in electrical shock or death WARNING Cut Hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts Important safety instructions To avoid hazard read and follow these instructions carefully before installing or using this appliance Please make this information available to the person installing the appliance as it could reduce your installation costs This appliance is to be installed and connected to the electricity supply only by a qualified electrician a Installation must comply with your local building and electricity regulations Failure to install the appliance correctly could invalidate any warranty or liability claims This
3. appliance is designed for permanent fixture and has to be connected to the mains electricity supply The appliance must not be installed above cookers with eye level grills a The appliance is heavy take care when lifting or handling Before you install the appliance please make sure that the voltage V and frequency Hz indicated on the serial number plate as well as the specifications on the rating plate on the inside of the appliance correspond to the voltage and frequency of the mains supply the room in which the appliance is installed is well ventilated the ceiling is able to withstand the total weight 56 kg of the appliance suspended from it if the air is to be ducted the flue is in good condition especially if it has been out of use for a long period of time If the air is to be ducted it will not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels the installation will comply with laws and regulations regarding ducting waste gases for optimal efficiency use smooth ducting for reduced noise and increased airflow Flexible ducting should only be used as a last resort When you install the appliance please make sure that a suitable isolating switch is incorporated in the permanent wiring mounted and positioned to comply with the local wiring rules and regulations The switch must be of an approved type installed in the fixed wiring and have a contact separat
4. height to fixed flue section E width of flue F depth of flue G H length of power supply cable G CLEARANCE DIMENSIONS ELECTRIC Clearances mm minimum clearance from bottom of VentSurface to A _ trivets or pot support surface of gas cooktops pot support surface of electric cooktops including induction Note to ensure that the VentSurface is able to perform at its best we recommend that the clearance between the VentSurface and the cooking surface does not exceed 800 mm oZ LIH 750 2 1 1 599489D izona vsisland install A2 NZGB indd 21 7 09 2 51 59 PM 4 PARTS SUPPLIED iP A S Support frame Vertical flue for vertical flue 4 x 50 Screws 4 S Ceiling Extendable mounting support mounting support 4x16 3 5 x 9 5 and corresponding Upper glass 1 Aluminium Plastic vent mounting flue cover 1 brackets 4 brackets 1 Washers 4 Screws 46 wall anchors 4 mesh filter 1 duct 1 frame 1 Note ducting accessories carbon filter and the Ductless Recirculating Kit are NOT supplied with your VentSurface but need to be purchased separately They are available from your nearest Fisher amp Paykel Authorised Service Agent or www fisherpaykel com VENTILATION OPTIONS RATING PLATE LOCATION Recirculation Requires Carbon Filter to External ducting be purchased separately as part of the Ductless Recirculating Kit Contact your nearest Fisher amp Paykel External ducti
5. ion in all poles that provide full disconnection under overvoltage category IIl conditions it is not installed and connected to flues where other appliances are installed and which run off energy supplies other than electricity eg water heaters boilers gas cookers the power supply cable type HO5VV F 3x0 75 mm is connected to terminals marked with the letters L power line and N neutral mounted on the appliance and is secured in position by a cable gland the power supply cable is connected to a suitable and easily accessible fixed power outlet or isolating switch the power outlet or isolating switch remains accessible after installation and the appliance can be disconnected from the electricity supply exhaust air is not discharged into a heating flue or wall cavity unless the cavity is designed for that purpose If you install using the external ducting through a side wall ensure the surface area of the external venting grill is no smaller than 150 cm the glass and stainless steel components are handled with care These are easily damaged if abraded or knocked by tools 1 2 1 599489D izona vsisland install A2 NZGB indd 21 7 09 2 51 59 PM 2 PRODUCT DIMENSIONS Installation diagrams for illustration purposes only Product dimensions mm height from top of glass surface to top of fixed flue section A overall height of product adjustable B overall width of product C overall depth of product D
6. ng Recirculation Authorised Service Agent or www fisherpaykel com for instructions and details through a side wall recirculates filtered air or ceiling back into the kitchen 2 2 1 599489D izona vsisland install A2 NZGB indd 21 7 09 2 51 59 PM D SECURE MOUNTING FRAME TO CEILING amp MOUNT UPPER GLASS Ensure the washers provided are used 1 1 2 599489D izona vsisland install A2 NZGB indd 21 7 09 2 52 11 PM 9 ATTACH VERTICAL MOUNTING BRACKETS amp SLIDE ON FLUE COVER Important VERY HEAVY Ensure that the ceiling is able to withstand the total weight 56 kg of the appliance suspended from it 2 1 2 599489D izona vsisland install A2 NZGB indd 21 7 09 2 52 11 PM 11 OPTIMISING THE VENTSURFACE BY SELECTING COOKTOP TYPE To ensure best performance the type of cooktop under the VentSurface needs to be selected after installing the appliance To select the type of cooktop 1 Make sure the VentSurface is on stand by plugged into a power outlet which is switched on but the fan is off Press the and buttons simultaneously A single horizontal segment will appear in the display 3 Release and re press the buttons simultaneously again to scroll through the types of cooktops Top segment Gas Middle segment Induction Bottom segment Electric Ceramic Gas Induction Electric Ceramic 4 To store the type of cooktop last selected
7. you removed the protective blue film from the stainless steel surfaces Is the VentSurface earthed LJ Ld OPERATION Have you informed the customer about the cleaning alerts Have you demonstrated the basic operation to the customer Installer s name Installer s signature Installation company Date of installation LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER www fisherpaykel co nz www fisherpaykel com au www fisherpaykel co uk www fisherpaykel ie 599489D NZ AU GB IE 07 09