FIELD CONTROLS Hardware platform 10 User's Manual
Contents
1. Change password J Reboot system After logging in the General page shows the following information Status indicates whether or not a script is running Host name network name of the unit IP address IP network address assigned to this unit currently 10 0 0 1 Product model the product type identification of the unit Software version currently installed firmware version Serial number unique serial identification also printed on the unit Logged in as name of the user currently logged in currently admin The configuration system is split into several tabs The User s Guide explains the web user interface in detail here we only discuss the system s IP settings Click the System tab to go to the System page CER International bv 17 Hardware Platform 10 Installation Guide The System IP page shows the following information General Script System DNS Services IP assignment M enable ARP PING to change the IP address MOS 0 0 0 1 IP address 255 0 0 0 subnet mask 127 0 0 1 default gateway obtain automatically from a DHCP bootp server use with care IP Internet Protocol DHCP Dynamic Host Configuration Protocol Bootp Bootstrap Protocol ARP Address Resolution Protocol These fields control the IP settings of FieldCommander Enable ARP PING In situations where you don t have access to your FieldCommander unit or you have lost its address ARP PING provides a solution to change it from y
2. References Javascript Reference Manual FCJSREF Extensive documentation of the Javascript ECMAscript core language used by FieldCommander for application programming PHP Language Manual Complete documentation of the PHP language and functions CER International bv 7 Hardware Platform 10 Installation Guide Installation This chapter explains the installation in detail and along the way it introduces you to some of the concepts important to understand the operation of your controller unit System requirements In order to connect to the controller you need a valid TCP IP network connection and a browser To be complete it requires e 10Mbit 10base T or 100Mbit 100base T network connection with RJ 45 socket e operating system with TCP IP protocol stack e Internet browser CER International releases firmware updates regularly with enhancements changes and fixes Updates may feature new functionality so it is a good idea to occasionally check the website at http www cer com for new firmware releases Getting familiar In this chapter we describe the connectors of your controller Depending on the product model all controls are located on the front of the unit or controls are on both sides Front Ethernet Power RS232 Serial port The 9 pin port is used to connect your controller to your serial equipment The chapter called Serial Interface uncovers the details of serial communication and pin out of the
3. pane ER a sS FieldCommander Installation Guide Hardware Platform 10 FChwp10 Safety Information The following are warnings or safety guidelines A warning means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Qualified Personnel Warning Only trained and qualified personnel should install or replace the device Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden Varoitus Ainoastaan koulutettu ja p tev henkil kunta saa asentaa tai vaihtaa t m n laitteen Avertissement L installation ou le remplacement de cet appareil doit tre r alis par du personel qualifi et comp tent Achtung Ger t nur von geschultem qualifiziertem Personal installieren oder auswechseln lassen Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio Advarsel Kun kvalifisert personell med riktig oppl ring b r montere eller bytte ut dette utstyret Aviso Este equipamento dever ser instalado ou substitu do apenas por pessoal devidamente treinado e qualificado iiAtenci n Estos equipos deben ser instalados y reemplazados exclusivamente por personal t cnico adecuadamente preparado y capacitado Varning Denna utrustning ska en
4. Warning Always disconnect the power cord from the controller when you are dis mounting devices interfaces or sensors Do not dis connect while the power is on A sudden rush of power can damage sensitive electronic components Follow these steps to connect the controller to your power supply 1 Make sure the power supply is unplugged 2 Connect the DC jack to your controller Now you can safely plug in your power supply Notice that the PWR indicator lights up Warning The controller has very low ESR input capacitors To avoid arcing please plug in the DC jack to the controller first then plug the AC adapter into mains CER International bv 11 Hardware Platform 10 Installation Guide Power Over Ethernet In your controller a passive power over Ethernet PoE scheme is implemented see below using the unused pairs of the LAN port for power Power input FCHWP10 7 20V 8 Power can be injected using passive POE splitter which can be ordered seperately LAN POE FieldCommander POE Splitter Power 12 Installation Connecting to the network Before connecting the controller to the network you might want to consult your network administrator You can employ the controller at various points in your ethernet network as shown below Make sure the IP addressing scheme of your controller does not interfere with your existing network configuration The chapter IP configuration takes the m
5. 16 3 x 11 25 x 3 0 cm 6 42 x 4 43 x 1 18 inch Die Cast Aluminium NEMA 67 casing wall or 1 mast mount 21 x 15 x 6 cm 8 3 x 5 9 x 2 4 inch without bracket one RS 232 serial port EIA TIA 232 C D sub 9 pins EIA TIA 574 15 2 meter max 50 feet 5 6 70r8 1 1 2 or 2 Even Odd Mark Space None Port 1 XON XOFF None Port 2 3 Optional XON XOFF CTS RTS DTR DSR None Port 1 TxD RxD GND Port 2 3 Optional TXD RxD RTS CTS DSR DTR CD RI GND 31 Hardware Platform 10 Installation Guide RS 485 Interface option only Interface one RS 485 serial port EIA TIA 485 A ISO 8482 Connector D sub 9 pins Distance 1220 meter max 4000 feet Data bits 5 6 7 or8 Stop bits 1 1 2 or 2 Parity Even Odd Mark Space None Flow control Automatic Signals DATA A DATA B GND Network Interface Interface 10 100Base T ethernet Connector RJ 45 Indicators Link and status LEDs Extra Power over Ethernet USB Interface option only Interface two USB serial ports Rev 2 0 compliant Connector USB type A Video Interface model C only Interface VGA Connector VGA 15 pin Audio Interface model C only 32 Interface Audio In Audio Out Connector jack 3 5mm Physical Dimensions Physical Dimensions a 112 5mm All sizes in millimeters CER International bv 33 Hardware Platform 10 Installation Guide Notice to the user Regulatory FCC Notice This device complies with Part
6. 172 16 0 0 to 172 31 255 255 192 168 0 0 to 192 168 255 255 Classes and subnets After receiving a network ID from your system administrator you must pick a unique ID for your CER controller Three classes are defined to accommodate networks of varying sizes The address class can be identified by the first octet of the address or network ID The examples in the table below use w x y z to designate the bytes of the IP address Network ID Host ID Subnet mask Subnet masks are 32 bit values that allow the recipient of IP packets to distinguish the network ID portion from the host ID Subnet masks are created by assigning 1 s to network ID bits and 0 s to host ID bits The 32 bit value is then converted to dotted decimal notation as shown in the table For example when the IP address is 192 168 4 1 and the subnet mask is 255 255 0 0 the network ID is 192 168 and the host ID is 4 1 To prevent addressing and routing problems all computers on a logical network must use the same subnet mask and network ID CER International bv 15 Hardware Platform 10 Installation Guide For FieldCommander controllers Assigning an IP address on a FieldCommander The factory default IP address of the controller is 10 0 0 1 with netmask 255 0 0 0 This address will suffice when you have a point to point connection with the controller or when the local network ID is 10 In this case the host ID of the controller already fits in in the range from 10 0
7. current IP address of your CER controller in the location address field http 10 0 0 1 admin The Login page should now appear see page 16 In case the page does not load check the proxy settings of your browser When the CER controller is on the local network or connected directly with a cross cable no proxy server should be used for its IP address 22 Serial interfaces Serial interface In this part of the installation manual you will learn some basics of serial communication the hardware involved and how the CER controller connects to your RS 232 device RS 232 The RS 232c standard The RS 232 standard RS stands for recommended standards was published first in 1969 by the EIA Electronic Industries Association It was originally drawn up to specify the connections between terminals and modems It specifies the electrical characteristics of circuits between the devices and gives names and numbers to the wires RS 232 C is the third and most common version of the standard so it is often simply referred to as RS 232 without the c The combination of ITU T s formerly CCITT V 24 and V 28 standards are equivalent to EIA RS 232 C In short V 24 V 28 RS 232 The characteristics of the RS 232c protocol are as follows point to point communication full duplex maximum line length between sender and receiver 15 meters 50 feet The connections In serial communication you ll encounter many references to th
8. environment as well as a basic overview of the serial communication hardware and IP addressing It provides all knowledge needed to connect the device in a way that the CER controller is accessible and ready for further use Organisation of the documentation Installation Installation Guide Hardware Platform 10 FCHWP10IG Bundles information related to the hardware such as the installation of the device IP networking serial interface details and technical specifications For ELS controllers Employment Software User s Guide ELSSWUG Explains the configuration of the ELS controller For EWS controllers Employment Software User s Guide EWSSWUG Explains the configuration of the EWS controller For FieldCommander controllers Employment Software User s Guide FCSWUG Explains how FieldCommander is used in your application development and documents all its features including the configuration Programming FCscript Programmer s Guide FCSCRPG Function reference of FieldCommander s scripting language used to create control applications FCphp Programmer s Guide FCPHPPG Function descriptions of the FieldCommander specific PHP interface used to build dynamic user interfaces on top of the control application Software options Modbus Software Option FCOPTO10 Galaxy Software Option FCOPT020 The option modules have their own documentation to explain the features installation configuration and programming interfaces
9. 0 0 to 10 255 255 255 In any other case you ll have to assign your controller a new IP address Configure IP address with browser The normal way is to change the IP address netmask and or default gateway is from a web browser For this to work the computer with the browser must be on the same subnet When this is not the case you can force the controller to accept a new IP address by way of ARP and PING commands see later this chapter To open the configuration pages of FieldCommander start your web browser and enter FieldCommander s IP address in the location address field http 10 0 0 1 admin The Login page should now appear FieldCommander Configuration Mozilla Firefox E PE File Edit View Go Bookmarks Tools Help User name 2004 CER International bv All rights reserved When the above page does not appear test the connection with PING see next chapter 16 IP configuration In case you forgot the address of FieldCommander you can force it to accept a new IP address by way of ARP and PING commands see later this chapter Now you should identify yourself before you can access any of the actual configuration pages Log in with the preconfigured admin account User name admin Password admin Note that both fields are case sensitive Note For security reasons it is strongly recommended to change this password See the User s Guide for instructions Running Host name eldCommander
10. A Backbone with stubs workable C Star network avoid B Daisy chain best D Mixed backbone amp star avoid If the traffic on the network is slow and the cable lengths are short topology is not an issue But as soon as transmission speeds are higher or distances longer you should be aware of the physical network layout The daisy chain configuration is the best choice The backbone and star networks are not impossible but it is hard to control reflections and harmful transmission line effects Line termination Termination resistors are used to match impedance of a node to the impedance of the transmission line being used When impedances are mismatched the transmitted signal is not completely absorbed by the load and a portion is reflected back into the transmission line If the source transmission line and load impedances are equal these reflections are eliminated Commonly used RS 485 cabling such as Category 5 CAT5 cable has an impedance of 100 Ohm When cables run longer than about 10 meters termination resistors of 100 Ohm should be installed at the both ends of the cable CER International bv 25 Hardware Platform 10 Installation Guide Automatic Data Flow Control Function for RS 485 The CER controller automatically senses the direction of incoming data and switches its transmission direction accordingly Therefore no handshaking signal e g RTS signal is necessary This feature lets you simply and quickly buil
11. connector Ethernet connector The CER controller is equipped with an Ethernet LAN controller that is fully compliant with IEEE 802 3 10 100Base T CSMA CD standards The Ethernet port provides a standard RJ 45 jack on board After completion of the startup process two LED indicators provide information about the status of the network connection The Green LED right indicates that there is a physical connection link to the network The Green LED left indicates network activity It flashes when there is any data on the line it s not necessarily addressed to the controller This connector implements a passive power over Ethernet scheme using the two unused pairs More about this can be found in the section Power over Ethernet in the next chapter Installation LED indicator Next to the Power Connector there is a green LED on the front panel for indicating system status This LED is lit when power is supplied to the unit Power connector Power to the controller is accommodated by a DC jack J9 or by passive power over ethernet connector The DC jack is attached to a 18V external DC power supply Power supplied to the unit must be within the specifications listed in this manual Back FC2700 FC3700 only USB RS232 RS485 USB FC373x only RS232 RS485 RS232 USB CER International bv 9 Hardware Platform 10 Installation Guide ELS1700 or EWS1700 only VGA Audio USB ELS172x only To be def
12. to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Industry Canada Notice This Class A digital apparatus complies with Canadian ICES 003 This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada 34 Notice to the user Declaration of Confority Declaration of Conformity according to ISO Guide 22 and EN 45014 Manufacturer s name CER International bv Manufacturer s address Postbus 258 4700 AG Roosendaal The Netherlands declares that the product Product Name FieldCommander Model Number ELS1700 ELS1722 EWS1700 EWS1722 FC2700
13. 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment CE Notice C This product has been tested and found
14. FC3700 FC3733 FC3724 Product Options all conforms to the following Product Specifications EMC Directive 89 336 EEC for CE Marking EN 55022 1998 Class A EN 61000 3 2 2000 EN 61000 3 3 1995 EN 55024 1998 IEC 61000 4 2 1995 IEC 61000 4 3 1995 IEC 61000 4 4 1995 IEC 61000 4 5 1995 IEC 61000 4 6 1996 IEC 61000 4 8 1993 IEC 61000 4 11 1994 Supplemental Information The product herewith complies with the requirements of the EMC Directive 89 336 EEC and carries the C marking accordingly A van den Broek General Manager Trademarks CER and FieldCommander are registered trademarks of CER International bv All other product names and services identified throughout this book are trademarks or registered trademarks of their respective companies They are used throughout this manual in editorial fashion only and for the benefit of such companies No such uses or the use of any trade name is intended to convey endorsement or other affiliation with this manual Copyrights Copyright 2008 CER International bv All rights reserved No part of this publication may be reproduced in any form or stored in a database or retrieval system or transmitted or distributed in any form by any means electronic mechanical photocopying recording or otherwise without the prior written permission of CER International bv except as permitted by the Copyright Act of 1976 and except that program listings may be entered stored and e
15. R ede ee t a a E CR 15 Assigning an IP address on a FieldCommander momo 16 Configure IP address with browser ees 16 Force new IP address using ARP PING erre 19 Assigning an IP address on an ELS controller lle 20 Assigning an IP address on an EWS controller o ooo oooooo o 2l Testing the Ethernet connection LL 22 The ping test amp ssp a pe ack eee a a aa o ala Ba gcn 22 The browser test sassari e ad ee RUN E Ratte den RR Oe ck a RU 22 Serial interface i 2x oco a ia a da a Be ow 23 SA A 23 The RS 232c standard 23 The connections a a ehh his 23 The RS 232c pin out LL Es RS 485 option only eee hh hrs 24 The RS 485 standard 24 The connections LL 24 The RS 485 pin out LL 26 Ports on your controller o 27 Pin Assignments Li 28 Technical Specifications clle rrr 31 Physical Dimensions creer hh hh htt 33 Notice to the User lee ec 9E E Wem e xe te wise ek er 34 Regulatory cea ke Rn c e OP A A a D De Te ode dece ee wa 34 a RET EDREEOTE SS TU TITLES 35 Soi c E rm 35 About this manual About this manual This document is intended for users of the FieldCommander ELS or EWS controllers that are based on the HWP10 platform and explains the steps to install and setup the system in your environment This guide contains information to install and configure the unit in your networking
16. ats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal instrument een slot en sleutel of een ander veiligheidsmiddel en welke beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie Varoitus Tama laite on tarkoitettu asennettavaksi paikkaan johon p sy on rajoitettua Paikka johon p sy on rajoitettua tarkoittaa paikkaa johon vain huoltohenkil st p see jonkin erikoisty kalun lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkil iden valvoma Attention Cet appareil est installer dans des zones d acc s r serv es o seul le personel de service peut y acc der soit en d verrouillant un cadenas soit en d sactivant un autre moyen de s curit L acc s aux zones de s curit est sous la responsabilit de l tablissement Warnung Diese Einheit ist zur Installation in Bereichen mit beschr nktem Zutritt vorgesehen Ein Bereich mit beschr nktem Zutritt ist ein Bereich zu dem nur Wartungspersonal mit einem Spezialwerkzeugs Schlo und Schl ssel oder anderer Sicherheitsvorkehrungen Zugang hat und der von dem f r die Anlage zust ndigen Gremium kontrolliert wird Avvertenza Questa unit deve essere installata in un area ad accesso limitato Un area ad accesso limitato un area accessibile solo a personale di assistenza tramite un attrezzo speciale
17. d an RS 485 network with just two wires More importantly application software previously written for half duplex RS 232 environments can be maintained without need for modification The RS 485 pin out See the chapter Pin Assignments for Hardware platform specific information about the pin out Caution Be sure to conform to the pin out of Hardware platform RS 485 ports when making direct connections to this port You may cause damage to your devices and or controller when incorrect cable layouts are beeing used 26 Serial interfaces Ports on your controller Hardware Platform 10 has different versions depending on the model you choose Model uss Port1 Port2 Ports eisi7oo 2xus2 0 rs232 E9172 2xuse2 0 rs 232 rs232 ELS1724 axuse2 0 RS 232 mRS B5 ews1700 2xuse2 0 rs23 ews1722 axuse2 0 rs 232 rs232 Available as option No handshake signals are available on port 1 When available Port 2 3 and 4 are equipped with full handshake signals CER International bv 27 Hardware Platform 10 Installation Guide Pin Assignments RS 232 and RS 485 Serial Ports 90000 0000 Rs 232 Rs 2szfun ass Pores Port 2 3 Option only Port 2 Option only eee 2 feo jJmo DATA A non inverting B IS O Power Connector o_ 0 Pin diameter 2 1mm Outer diameter 5 5mm Lem Signal Name CTE outer enD 28 Pin Assig
18. dast installeras och bytas ut av utbildad och kvalificerad personal Installation Warning Read the installation instructions before you connect the device to a power source Waarschuwing Raadpleeg de installatie aanwijzingen voordat u het systeem met de voeding verbindt Varoitus Lue asennusohjeet ennen j rjestelm n yhdist mist virtal hteeseen Attention Avant d alimenter cet appareil veuillez consulter le manuel d installation Warnung Lesen Sie die Installationsanweisungen bevor Sie das System an die Stromquelle anschlie en Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all alimentatore Advarsel Les installasjonsinstruksjonene f r systemet kobles til stramkilden Aviso Leia as instru es de instala o antes de ligar o sistema sua fonte de energia Atenci n Ver las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Varning Las installationsanvisningarna innan du kopplar systemet till dess str mf rs rjningsenhet Restricted Access Area Warning The device is intended for installation in restricted access areas A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool lock and key or other means of security and that is controlled by the authority responsible for the location Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang Een pla
19. e device Battery This device contains a non rechargebale battery Do not short cut the battery Please ensure that if the battery is replaced that the new part conforms to the same specifications Electromagnetic Compatibility EMC The EWS1700 is classified as a component with regards to the European Community EMC regulations and it is the users responsibility to ensure that systems using this device are compliant with the appropiate EMC standards Packaging Please ensure that if a device should be returned to CER it is adequately packed preferable in the original packing material Hardware Platform 10 Installation Guide Table of Contents Safety Information 0 o o ooooooo mrrrr hh hrs 3 Qualified Personnel Warning ll 3 Installation Warning lees 3 Restricted Access Area Warning 4 About this manual use ec a ee ERN RR S 7 Installati0N 000 a a a a ee Rm d 8 Syst m requirements Junk bo UE aa a 8 Getting familiar 2 244 parigini piatta lena bare deeds 8 FFONE uuu E aa ROBORE na SE S 8 Back aduer ee acaba ats eo Se e ke De WE RC a ee aer as we Sa 9 BOCOM sei ani ton a ae ERGO X x te BOR OR ON M OR ROO X E 3 Ede 10 Hardware installation eer hrs 11 Physical installation leer nn 11 Connecting DOWGF ux eae eee e x RR RECURSO UR RC e RA e Be a 11 Connecting to the NetWork 13 IP configuration rsr ee 15 Addressing basics secas a Rx RO RE oe qe OUR U
20. e rather cryptic terms DTE Data Terminal Equipment and DCE Data Communication Equipment The word terminal indicates the end of the line as in bus terminal In the phrase data terminal equipment it means the extreme ends of the data communications circuit The data communications equipment modems for example provide the communication between the two DTEs Computer Terminal RS 232c RS 232c TELEPHONE NETWORK DTE DTE The RS 232c pin out The 9 pin RS 232c connector is described in the EIA TIA 574 standard See the chapter Pin Assignments for Hardware platform specific information about the pin out CER International bv 23 Hardware Platform 10 Installation Guide RS 485 option only The RS 485 standard The RS 485 communication protocol is the industry s most widely used bidirectional balanced transmission line standard It is specifically designed for industrial multi drop systems that should be able to transmit and receive data at high rates or over long distances RS 485 RS stands for recommended standards is accepted as a standard in 1983 by the EIA Electronic Industries Association The full name of the latest revision is TIA EIA RS 485 A published March 3 1998 which is equivalent to the ISO 8482 standard The characteristics of the RS 485 protocol are as follows bi directional master slave communication over a single twisted pair half duplex up to 32 nodes per segment
21. einheiten das Netzkabel ab bzw schalten Sie bei Gleichstromeinheiten den Strom am Unterbrecher ab Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori scollegare il cavo di alimentazione sulle unit CA scollegare l alimentazione all interruttore automatico sulle unit CC Advarsel F r det utf res arbeid p kabinettet eller det arbeides i n rheten av str mforsyningsenheter skal str mledningen trekkes ut p vekselstr msenheter og str mmen kobles fra ved strgmbryteren p likestramsenheter Aviso Antes de trabalhar num chassis ou antes de trabalhar perto de unidades de fornecimento de energia desligue o cabo de alimentac o nas unidades de corrente alternada desligue a corrente no disjuntor nas unidades de corrente cont nua Advertencia Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentaci n desenchufar el cable de alimentaci n en los equipos de corriente alterna CA cortar la alimentaci n desde el interruptor autom tico en los equipos de corriente continua CC Varning Innan du arbetar med ett chassi eller n ra str mf rs rjningsenheter skall du f r v xelstr msenheter dra ur n tsladden och f r likstr msenheter bryta str mmen vid 6verspanningsskyddet Device handling Anti Static handling The device contains CMOS devices that could be damaged in the venet of static electricity discharged through them At all times use anti static precautions when handling th
22. ernational bv 19 Hardware Platform 10 Installation Guide For ELS controllers Assigning an IP address on an ELS controller The IP address on an ELS controller is defined in a configuration file and set to 10 0 0 1 by default To change this IP address connect to the ELS using an USB keyboard SSH or the serial console Then log in using username password default els e sroot and edit the file etc network interfaces DHCP auto eth iface eth inet dhcp Fixed IP 10 0 0 1 auto eth iface eth inet static address 10 0 0 1 gateway 127 0 0 1 netmask 255 0 0 0 network 10 0 0 0 broadcast 10 0 0 255 The ELS must be rebooted for the changes to take affect 20 IP configuration For EWS controllers Assigning an IP address on an EWS controller The IP address on an EWS controller is defined in a configuration file and set to 10 0 0 1 by default To change this IP address connect to the ELS using an USB keyboard SSH or the serial console etc ne DHCP auto et iface e Fixed IP auto et iface e address gateway netmask network broadca Then log in using username password default els e sroot and edit the file twork interfaces h th inet dhcp 10 0 0 1 h th inet static 10 0 0 1 127 0 0 1 2555027 0410 10 0 0 0 st 10 0 0 255 The EWS must be rebooted for the changes to take affect CER International bv 21 Hardware Platform 10 Installation Guide Testing the Eth
23. ernet connection The ping test The most basic way to test the network connection is to do a so called ping test When the connection is working the CER controller will answer with an echo or pong Start a command prompt on your local machine and type the following command ping lt IP address gt Example ping 10 0 0 1 The response will be something similar to the following Reply from 10 0 0 1 bytes 32 time 1ms L 128 Reply from 10 0 0 1 bytes 32 time 1ms L 128 This means the Ethernet connection is working and the IP settings are correct You should be able to open the web page with your browser see next text However if PING displays something like Request timed out Request timed out It appears that your system did not receive a response back Maybe the unit is configured to a different address or you have a hardware problem You can try to ping another machine to test if the cabling and network configuration is correct When it fails check the cabling and network setup In case you see a response like Destination host unreachable This indicates that the address you try to ping is outside of your subnet and you did not define a correct gateway router address on the machine Fix the IP settings of your machine and try pinging again Note that you might have to restart your machine first The browser test When the ping test has passed start a web browser on your local machine and enter the
24. ined VGA Audio USB Serial port The 9 pin port is used to connect your controller to your serial equipment The chapter called Serial Interface uncovers the details of serial communication and pin out of the connector USB connectors The back panel features two USB connectors Bottom Serial Number The affixed label on the back of the unit states the products serial number which is identical to its MAC address 10 Installation Hardware installation You communicate with the controller over the Ethernet network In this part of the chapter you ll learn about the unit itself and how and where to connect it There are no configurable parts inside Everything is controlled and configured by the software Physical installation You can use the controller in several places depending on your needs e freely unfixed on your desktop with the included adhesive plastic bumpers e fixed to a DIN rail using the supplied DIN rail clips These can be inserted into the holes in the case Be sure to position the rebated joints at the outside of the Controller for easy removal of the case from the DIN rail in the future e if outdoor option fixed to a wall or 1 mast using the waterproof NEMA 67 outdoor case Connecting power The controller requires power of a single 7 18VDC The power consumption is rated at 12VDC 0 25A and 12VDC 0 4Auax This can be applied using a Power adaptor or Power Over Ethernet Power adaptor
25. lucchetto o altri dispositivi di sicurezza ed controllata dall autorit responsabile della zona Advarsel Denne enheten er laget for installasjon i omr der med begrenset adgang Et omr de med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verkt y l s og n kkel eller en annen sikkerhetsanordning og det kontrolleres av den autoriteten som er ansvarlig for omr det Aviso Esta unidade foi concebida para instala o em reas de acesso restrito Uma rea de acesso restrito uma rea qual apenas tem acesso o pessoal de servi o autorizado que possua uma ferramenta chave e fechadura especial ou qualquer outra forma de seguran a Esta rea controlada pela autoridade respons vel pelo local Advertencia Esta unidad ha sido dise ada para instalarse en reas de acceso restringido rea de acceso restringido significa un rea a la que solamente tiene acceso el personal de servicio mediante la utilizaci n de una herramienta especial cerradura con llave o alg n otro medio de seguridad y que est bajo el control de la autoridad responsable del local Varning Denna enhet r avsedd f r installation i omr den med begr nsat tilltr de Ett omr de med begr nsat tilltr de f r endast tilltr das av servicepersonal med ett speciellt verktyg l s och nyckel eller annan s kerhetsanordning och kontrolleras av den auktoritet som ansvarar f r omr det Disclaimer The information in this man
26. maximum line length per segment of 1200 meters 4000 feet By using repeaters multiple networks segments can be chained together to accommodate virtually an unlimited number of nodes As with the implementation of many standards there is a difference between theory and practice Though the RS 485 standard mentions a maximum of 32 nodes and a line lenght of 1200 meters in practice it depends on the used transceivers cable quality and network topology For a deeper understanding of RS 485 in real world applications check the list of recommended literature at the end of this manual The connections RS 485 is not difficult though some care has to be taken when adding a controller as a new device on the bus This chapter explains some of the basic terms and wiring strategy though it does not intend to go into to much detail To learn more about the practical use of RS 485 please refer to many excellent resources on this subject Find a list of recommended literature at the end of this installation manual Masters and Slaves RS 485 is used for multi point communications more devices may be connected to a single signal cable Most RS 485 systems use the Master Slave architecture where each slave unit has its unique address and responds only to packets addressed to this unit These packets are generated by the master e g PC which periodically polls all connected slave units In Master Slave systems slaves never start the communication
27. nments Ethernet 12345678 no nc n che T T MT a s Gen 3 jme 17 Brown white 4 POE GND power return ls Brown 4 POE GND power return USB Ports Cable Device CER International bv 29 Hardware Platform 10 Installation Guide VGA Note In the ELS an Award BIOS is used The combination of Award BIOS and Linux kernel will detect a VGA monitor at boottime and won t boot when no monitor is connected 1 veaRed EM VGAGreen 3o VGABIue en 9 kevec sv 12 DDC data 13 HS Hor Sync 14 VS Vert Sync Audio In amp Out Pm Sina Audio line In Audio line Out GND 30 Technical Specifications Technical Specifications Hardware CPU Memory Storage Indicators Power supply voltage Power consumption Operating temperature Case Indoor Mechanical Dimensions WxDxH Outdoor version Mechanical Dimension WxDxH RS 232 Interface Interface Connector Distance Data bits Stop bits Parity Flow control Signals CER International bv type A 433MHz AMD Geode LX700 type B C 500MHz AMD Geode LX800 type A 128 MB SDRAM type B C 256 MB SDRAM type A B 1GB GB Flash drive 256MB reserved for system type C 4GB GB Flash drive 256MB reserved for system Power LED 7 18V DC on power adapter plug 0 25 0 4A max at 12V DC excl USB devices 0 50 C 32 122 F Aluminum casing desktop use or DIN rail mount
28. our workstation see next chapter When you uncheck the box this feature is disabled which may lock you out of FieldCommander so do not uncheck this box unless you know what you are doing Manual IP settings Fill out the new IP address subnet mask and default gateway router address here Set the default gateway to 127 0 0 1 when you are not using a gateway or router or you don t know what it is For details about the addressing see chapter IP configuration DHCP bootp server Instead of manually configuring the IP addresses they can be assigned automatically using DHCP and bootp Consult your network administrator if there is a DHCP or bootp server present Don t use this setting unless you know exactly what your are doing Caution Be aware that when your FieldCommander is assigned a dynamic address you may not know which address to enter in order to access it Use this setting with care You have to restart the system in order for the new settings to take effect Note that you have to point your browser to the new address and log in again when you ve changed IP settings 18 IP configuration Force new 1P address using ARP PING When FieldCommander is outside of your subnet or or you don t recall it s current address you cannot open the configuration web pages to change the IP settings To solve this you can force FieldCommander to accept a new IP address by way of ARP and PING commands Windows 95 98 ME NT 2000 XP To fo
29. r future reference during installation You find the number on the label on the back of the unit 14 IP configuration IP configuration Your CER controller uses the common TCP IP protocols to provide the connection to the client machine over Ethernet Like any server or device it needs a unique IP number to be addressed This chapter shows the basic concepts necessary to install and operate the controller it does not intend to be a TCP IP networking guide Addressing basics Unique address Every device attached to a TCP IP network is identified by a unique IP address which is a 32 bit number To make it easier to memorize such addresses they are usually expressed as four 8 bit numbers between 0 and 255 seperated by dots e g 192 168 4 1 There are restrictions on using O and 255 so avoid those in an address Although an IP address is a single value it consists of two parts the network ID and the host ID of your computer The network ID identifies the systems located on the same physical network The host ID identifies a workstation server router or other TCP IP device within the network Even if a network is not connected to the Internet it has become custom to choose an address in a range reserved for private networks That makes it possible to connect your private network to the Internet later without having to reconfigure The following ranges are reserved for local use taken from RFC 1597 10 0 0 0 to 10 255 255 255
30. rce a new IP address into FieldCommander start a command prompt and type the following commands arp s lt new IP address gt lt serial number gt ping lt new IP address gt Example arp s 192 168 4 1 00 d0 c9 48 29 77 ping 192 168 4 1 The response will be something similar to the following Request timed out Reply from 192 168 4 1 bytes 32 time 1ms TTL 128 Reply from 192 168 4 1 bytes 32 time lt 10ms TTL 128 Reply from 192 168 4 1 bytes 32 time lt 10ms TTL 128 The new address takes effect immediately and you can access FieldCommander with that IP address through your browser right away You will now have to use the web browser to make permanent changes to the IP configuration Unix Linux and OS 2 arp is part of the net tools package in Unix and Linux so you might need to install this first To force a new IP address into FieldCommander type the following commands arp s new IP address serial number temp ping new IP address Example arp s 192 168 4 1 00 d0 c9 48 29 77 temp ping 192 168 4 1 You will see a response similar to this 64 bytes from 192 168 4 1 icmp seq 1 ttl 255 time 50 usec 64 bytes from 192 168 4 1 icmp_seg 2 ttl 255 time 53 usec The new address takes effect immediately and you can access FieldCommander with that IP address through your browser right away You will now have to use the web browser to make permanent changes to the IP configuration CER Int
31. s In Multi Master systems each node can initiate its own transmission creating the potential for data collisions This type of system requires a more sophisticated method of error detection including methods such as line contention detection acknowledgment of transmission and a system for resending corrupted data This is not specified in the RS 485 standard 24 Serial interfaces Network topology and wiring Multi drop RS 485 implies that there are two main wires in a segment labeled DATA and DATA or simple A and B The wiring comes as a twisted pair To reduce electrical noise it should be twisted as tightly as possible It is advisable to follow the standard colors used for the communication lines Yellow for DATA A Green for DATA B For safe operation a signal ground line should also be connected in the system All connected devices tap from these two lines with so called drop cables The connections are parallel so connecting or disconnecting of a node does not affect the network as a whole The network configuration isn t defined in the RS 485 specification The designer can use a configuration that best fits the physical requirements of the system In existing systems one should obey the rules of that network of course Bi
32. ual has been carefully checked and is believed to be accurate CER assumes no responsibility for any infringements or patents or other rights of third parties that may result from its use CER assumes no responsibility for any inaccuracies that may be contained in this document CER makes no commitment to update or keep current the information in this manual CER reserves the right to make improvements to this document and or products at any time and without notice Software License Terms End User License Agreement This device contains software The software is licensed Read the software licensen terms and check the User s Guide for detailed info Power Supply Disconnection Warning Before working on the device or near power supplies disconnect the power Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen voor gelijkstroom toestellen dient u de stroom uit te schakelen bij de stroomverbreker Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimell ennen kuin teet mit n asennuspohjalle tai ty skentelet virtal hteiden l heisyydess Attention Avant de travailler sur cet appareil veuillez couper les alimentations courant alternatif et continu de celui ci Warnung Bevor Sie an einem Chassis oder in der N he von Netzger ten arbeiten ziehen Sie bei Wechselstrom
33. xecuted in a computer system THE INFORMATION AND MATERIAL CONTAINED IN THIS MANUAL ARE PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY CONCERNING THE ACCURACY ADEQUACY OR COMPLETENESS OF SUCH INFORMATION OR MATERIAL OR THE RESULT TO BE OBTAINED FROM USING SUCH INFORMATION OR MATERIAL NEITHER CER INTERNATIONAL BV NOR THE AUTHORS SHALL BE RESPONSIBLE FOR ANY CLAIMS ATTRIBUTABLE TO ERRORS OMISSIONS OR OTHER INACCURACIES IN THE INFORMATION OR MATERIAL CONTAINED IN THIS MANUAL AND IN NO EVENT SHALL CER INTERNATIONAL BV OR THE AUTHORS BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF SUCH INFORMATION OR MATERIAL CER International bv 35 from Device to Enterprise The latest documentation is available from http www cer com FieldCommander is a product of CER International bv Postbus 258 NL 4700 AG Roosendaal The Netherlands TEL 31 0 165 557417 FAX 31 0 165 562151 http www cer com Part no FCHWP10IG revision 3 5 34
34. yths out of it Three ways to connect your controller to Ethernet O Local LAN Remote WAN Local LAN Remote WAN Point to Point Point to Point gateway router The controller is part of the local Ethernet network by connecting it to the hub or switch using a straight cable just like your own workstation When you co locate the controller you can connect to it through a public network like the Internet In this case the controller is connected to the network through your Internet gateway router with Port Forwarding support using the supplied straight cable The gateway router establishes the connection between your ISP and the controller You can connect the controller to your workstation directly using a crossed ethernet cable not supplied Use this setup where you don t have a Ethernet LAN available or when you don t want to use it for the controller Decide first where you want to connect the CER controller as it affects some of the steps in the installation most importantly cabling requirements and IP configuration CER International bv 13 Hardware Platform 10 Installation Guide To connect the CER controller to your 10 100base T network you can use any standard Category 5 CAT5 A suitable cable is supplied Attach one side to the RJ 45 socket marked Ethernet on the front panel of the unit and the other to your ethernet hub or switch Take note of the serial number of your CER controller fo
Download Pdf Manuals
Related Search
Related Contents
February 2010 デジタルトライアックスカメラアダプターシステム 1403 1038KB 1 / 2 取扱説明書を必ずご参照ください。 改訂:** 2015 年 3 月 21 日(第 5 Bulletin de réservation du premier semestre v1-09_Section_10_Gri.. Bosch WAK24260GB washing machine PATH ANALYSIS FOR PROCESS TROUBLESHOOTING Biao Circuits respiratoires pour réanimation néonatale avec Composition Propriétés et caractéristiques Mode d`emploi 2014年9月号(Vol.246) PDF形式 9.1Mbyte Copyright © All rights reserved.