1. at the electrical outlet Check the fuse or breaker 1 The fan switch or motor may be defective Replace if necessary LIMITED WARRANTY This warranty is extended to the original purchaser only It does not cover damages incurred during shipping or through accident neglect or abuse by the owner Essick Air Products Champion Cooler does not authorize any person or representative to assume any other or different liability in connection with this cooler All original parts provided by Essick Air Products Champion Cooler are warranted against defects in material or factory workmanship for one year Essick Air Products Champion Cooler is not respon sible for incidental or consequential damage resulting from any malfunction Essick Air Products Champion Cooler is not respon sible for any damage occurring from the use of water softeners chemicals de scale material or if a higher horsepower motor is used in the unit other than what Essick Air Products recommends Essick Air Products Champion Cooler is not respon sible for the cost of service calls to diagnose cause of trouble or labor charge to repair and or replace parts Contact the Dealer where you purchased the evapora tive cooler If for any reason you are not satisfied with the response from the Dealer contact the Customer Service Department Essick Air Products 5800 Murray Street Little Rock Arkansas 72209 or call 800 643 8341 Register your product online at
2. manguera clara del tubo negro Ponga en marcha la unidad a COOL y bombee fuera la mayor a del agua Limpie seco con una toalla Reconecte la manguera clara al tubo negro de agua antes de reconectar la rejilla posterior LOCALIZACI N DE AVER AS A PROBLEMA Enfriador No Bombea Agua PROBLEMA Ventilador No Funciona Terminos Y Condiciones De La Garant a Exclusiones De La Garant a Como Obtener Servico Bajo Esta Garant a Registrar La Unidad ADVERTENCIA Siempre desconecte el enfriador antes de procurar cualquier tipo de servicio CAUSA POSIBLE REMEDIO 1 La manga de la bomba puede haberse aflojado Verifique la conexi n en la bomba y en el tubo de agua localizado en el montaje de rejilla posterior Reconecte la manga de bomba si es necesario 2 El tubo de agua se puede bloquear Quite el tubo y l mpielo para asegurar que hoyos de agua est n claros 3 La bomba o el interruptor pueden ser defectuosos Reemplace la bomba o el interruptor si necesario CAUSA POSIBLE REMEDIO 1 Verifique si hay 115 voltios de electricidad en la toma de corriente Compruebe el fusible o el cortacircuito 1 El interruptor del ventilador o el motor pueden ser defectuosos Reemplace el interruptor o el motor si es necesario GARANT A LIMITADA Esta garant a es extendida solamente al comprador origi nal No cubre los da os contra dos durante el envio ni por el accidente por el descuido ni por el ab
3. ANCO ACANALADO VERDE TIERRA Antes De Funcionar Llenar El Dep sito De Agua Instalaci n Del Flotador Funcionamiento ZN Motor Bomba Filtro Dep sito De Agua Desempaquete su enfriador evaporativo e instale las ruedecillas Deslice los vastagos de las ruedecillas dentro de los agujeros proporcionados en el fondo de la rejilla anterior y la rejilla posterior FUNCIONAMIENTO DEL ENFRIADOR EVAPORATIVO AN ADVERTENCIA Para reducir el riesgo de fuego o golpe el ctrico no usa este ventilador con cualquier artefacto de control de la velocidad del estado s lido Seleccione el rea que usted desea refrescar Los enfria dores evaporativos funciona lo m s mejor cerca de una puerta o de una ventana parcialmente abierta para traer adentro aire fresco Se debe descargar del cuarto una cantidad igual de aire que se entra el cuarto para disipar calor y humedad Llene el dep sito por detr s del enfriador El dep sito aguanta 5 1 2 galones de agua NO SOBRELLENE El agua se escapar hacia fuera y pod a causar da o de agua al rea alrededor Si el dep sito llega a ser seco no da a r la bomba Si la unidad necesita ser transportada a una otra ubicaci n tenga muy cuidad de no derramar el agua Es mejor trasladar el enfriador antes de agregar el agua Un flotador es incluido para el relleno autom tico del agua Para instalar el flotador quite la rejilla posterior Quite la
4. Lea y Conserve Manual De Instrucci n Instrucciones ULTRACOOL Enfriador Evaporativo M vil Modelo M150 Picken en su compra de esta enfriador Es el mejor enfriador que su dinero puede comprar El dise o nico de este enfriador evaporativo m vil le provea dos caracter sticas Primero convierte el aire caliente y seco a una brisa refrescante Segundo puede ser utilizado como ventilador para circular el aire cuando hay demasiada humedad en el aire Essick Air Products Champion Cooler 5800 Murray Street Little Rock AR 72209 www essickair com Read amp Save These Instructions Instruction Manual ULTRACOOL Mobile Evaporative Cooler Model M150 GC sardines on your cooler pur chase It s the best cooler your money can buy The unique design of this mo bile evaporative cooler provides you with two features First it converts hot dry air into a cool refreshing breeze Sec ondly it can be used as a fan to circu late air when there is too much humidity in the air Essick Air Products Champion Cooler 5800 Murray Street Little Rock AR 72209 www essickair com 110489 1 Before Operation Unpack your cooler and install the casters Slip the stems of the casters into the holes provided in the bot tom of the front and back grille EVAPORATIVE COOLER OPERATION CAUTION To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control dev
5. ice PROBLEM Cooler Does Not Pump Water A Select the area you wish to cool Evaporative coolers work best near a partially opened door or window to draw in fresh air An equal amount of air should be discharged out of the room to dispel heat and humidity Fill the reservoir from the back The reservoir holds 5 1 2 gallons of water DO NOT OVER FILL Water will leak out and could cause water damage to the sur rounding area If the reservoir runs dry it will not harm the pump When transporting the unit to a different location be very careful not to spill the water It is best to re locate the cooler and then add water Fill Reservoir PROBLEM Fan Does Not Operate Float Installation Included is a float for continuous fill To attach the float remove the back grille Remove the nuts from the float and insert the float into the water shield and then through the hole in the housing Secure the float with the nut that was removed You may connect ei ther a 1 4 inch hose or a garden hose using the garden hose adapter Adjust the float so that the water level is about an inch below the top of the reservoir Reinstall the back grille Operation Plug the electrical cord into a 115 120 volt grounded outlet You may operate your cooler on one of three speeds low medium or high Turn the switch knob clockwise to activate the pump and fan This will cool the air Turn the switch counterclockwise to operate the cooler as a fan o
6. nly pump will be off Terms And Conditions Of Warranty Exclusions From Warranty MAINTENANCE CAUTION To reduce the risk of fire always unplug the cooler before attempting service of any kind No oil or lubrication is necessary The motor is perma nently lubricated at the factory No oil or lubrication is necessary Clean any debris from under the pump in the inlet area Remove the filter from the rear grille and rinse with water Be careful not to damage the filter The filter should be replaced every two years or if it becomes clogged How To Obtain Service Under This Warranty Water Tank Drain and clean the water tank To drain remove the back grille and disconnect the clear hose from the black tube Turn unit on cool and pump out most of the water Wipe dry and clean with a towel Before reattaching the back grille reconnect the clear hose to the black water tube Register Product TROUBLE SHOOTING CAUTION Always unplug the cooler before attempt ing service of any kind POSSIBLE CAUSE REMEDY 1 The pump hose may have worked loose Check the connection at the pump and at the water tube located in the back grille assembly Reconnect pump hose if necessary 2 The water tube may be blocked Remove the tube and clean it out Make sure water holes are clear 3 The pump or switch may be defective Replace pump or switch if necessary POSSIBLE CAUSE REMEDY 1 Verify there is 115 volt power
7. s tuercas del flotador e inserte el flotador a trav s del agujero en el salpicadero del flotador y en la caja Asegure el flotador con la tuerca previamente quitada Se puede co nectar una l nea de agua de 1 4 pulgadas o una manguera de jard n usando el adaptador para manguera de jard n Ajuste el flotador de modo que el nivel de agua sea una pulgada debajo de la tapa del dep sito de agua Reinstalle la rejilla posterior Enchufe el cable el ctrico en una toma de corriente de 115 120 voltios con toma de tierra Se puede funcionar su enfriador en una de tres velocidades bajo medio o alto Gire la perilla del interruptor a la derecha para activar la bomba y el ventilador Esto refrescar el aire Gire la peri lla del interruptor a la izquierda para funcionar el enfriador solo como un ventilador bomba estar apagada CONSERVACI N ADVERTENCIA Para reducir el riesgo de fuego o golpe el ctrico siempre desconecte el enfriador antes de procu rar cualquier tipo del servicio El motor no requiere aceite ni lubricaci n Se lubrica per manentemente en la f brica La bomba no requiere aceite ni lubricaci n Limpie cual quier escombros bajo la bomba en el rea de entrada Quite el filtro de la rejilla posterior y acl relo con agua Tenga cuidado de no da ar el filtro El filtro se debe cam biar cada dos a os o si se atasca Desagie y limpie el dep sito de agua Para desaguar quite la rejilla posterior y desconecte la
8. uso del due o Essick Air Products Champion Cooler no autoriza ninguna persona ni representante para asumir cualquier otra res ponsabilidad diferente con respecto a este enfriador Todas las piezas originales provistas por Essick Air Products Champion Cooler son garantizadas por un a o contra defecto de material y de fabricaci n Essick Air Products Champion Cooler no es responsable de da o incidental ni consecuente resultando de ning n funcionamiento defectuoso Essick Air Products Champion Cooler no es responsable de ning n da o que ocurra por el uso de suavizadores de agua las sustancias qu micas las materias que desin crustan o si un motor m s alto de potencia de caballo que Essick Air Products recomienda se usa en la unidad Essick Air Products Champion Cooler no es responsable del costo de llamadas de servicio para diagnosticar la causa del problema ni la carga del trabajo para reparar y o reemplaza las piezas Avisa el Comerciante donde usted compr el enfriador Si por cualquiera raz n usted no esta satisfecho con la res puesta del Comerciante avise el Departamento del Ser vicio de Cliente Essick Air Products 5800 Murray Street Little Rock Arkansas 72209 o llamar 800 643 8341 Registre su producto en l nea a www essickair com eac onlineregistration eac htm
9. www essickair com eac onlineregistration eac htm REPLACEMENT PARTS LIST LISTA DE PIEZAS DE RECAMBIO Part No 110822 4 110845 22 110850 2 110846 2 110438 224135 001 110441 4 110394 2 110849 2 110845 24 110425 1 310718 1 110588 1 110721 155001 14 110121 1 110122 1 110845 21 FL C 110852 110824 Description Casters 4 req d Front Grille Reservoir Fan Blade Pump Pump Mount Motor Power Cord Handle Knob Switch Hose Tube Tube Cap Pad Retainer 2 req d Poly Pad Media Back Grille Float Water Shield Garden Hose Adapter Descripcion Ruedecilla 4 req d Rejilla Anterior Dep sito De Agua Hoja De Ventilador Bomba Soporte De La Bomba Motor Cable De Corriente Asidero Perilla Interruptor Manga Tubo Tapa Del Tubo Soporte De Filtros 2 req d Filtro De Poliester Medio Evaporativo Rejilla Posterior Flotador Salpicadero del Flotador Adaptador para Manguera De Jardin WIRING DIAGRAM 3 SPEED SWITCH B O 0000 n TU TU lt SMOOTH RIBBED GREEN WIRE NUT OR CRIMP TERMINAL pa ENG S 7 GREEN GROUND ESQUEMA DE CABLEADO INTERRUPTOR DE 3 VELOCIDADES B A ABASTECIMIENTO DE 115V TTT EMPALME PLASTICO ACANALADO i S 7 NEGRO LISO BL