Home
Epson Pulsense PS-500 User's Manual
Contents
1. Go to Regional Settings in PULSENSE View to select your language Press the A or B Button to write the settings to your device How to use e 37 Other Functions LAI Notification Settings on page 39 Wake up Alarm on page 40 Fitting adjustment on page 41 Other Functions e 38 Notification Settings The PS 500 can alert you of E Mails calls or schedule notifications received on your smart device The notification settings must be set in PULSENSE View See Help section in the PULSENSE View for details Note The PS 500 must be connected via Bluetooth to your smart device Some additional settings might be required in the Notifications Settings of your smart device See your smart device manual for details Some Android devices may not support this function Other Functions e 39 Wake up Alarm You can set a sleep phase alarm to wake you at a light sleep phase making it easier to wake up You need to set the alarm time and a window time during which PULSENSE can wake you up For example if you set 7am as your alarm time and 30 minutes as your window PULSENSE will vibrate to wake you in a light sleep phase between 6 30 and 7 00 Other Functions e 40 Fitting adjustment The PS 500 has a tool to correctly adjust the strap for optimal heart rate reading 1 Wear the product loose hold the B Button and remember the wrist band hole number gt on 0000000000 N
2. In areas in which usage is restricted such as on airplanes and in hospitals follow the rules and regulations provided such as in flight announcements Do not use the device if you have a surgically implanted medical device such as cardiac pacemaker Do not bring the device into an operating room intensive care unit and so on and do not use the device near medical equipment Radio waves from the device may interfere with electronic medical equipment causing the equipment to malfunction and cause an accident This device is equipped with Bluetooth Smart technology When operating supported HR monitors or smart phones this function wirelessly sends and receives heart rate measurement data to the device This device has been certified as a wireless device based on the Radio Law Therefore the following acts may be punishable by law Disassembling or remodeling the device Removing the verification or certification number for the device Using this Device Safely e 9 Set up and Basic Operation You need to make the following preparations before use Things You Can Do with the Product on page 11 What s in the box on page 12 LF Operating buttons and functions on page 13 LY Getting Started on page 15 Initial Configuration on page 18 Set up and Basic Operation e 10 Things You Can Do With The Product Measuring items items Contents Heart rate The PS 500 reads and records your
3. and display is shown when heart rate can t be detected PS 500 sScreen State support It is likely that the device is not Wear the product closely around rror fitted correctly onto your wrist your wrist Tighten the wrist band if your pulse is not measured correctly It is likely that the device is not Wear the product closely around fitted correctly onto your wristor your wrist Tighten the wrist band the temperature on the surface of if your pulse is not measured your skin is too low correctly and warm your wrist and fingertips if they seem cold Try the below to facilitate heart rate detection Try to keep your body and arms still Position the arm below your heart Do not cross your arms 2 Once detection is complete your heart rate will be displayed on the screen as shown below ii OH 103 10 23 1e 24 TUE How to use e 23 Heart rate zones You can check your heart rate zone using the product LEDs Settings can be made via PULSENSE View to determine when the LEDs will illuminate See below table for the available settings EEN LED LED of max LED settings heart rate TAP FLASH BULLO Under 40 Blinking OFF If you tap the LED will blink 50 59 nnn 0000000000 80 89 T toco Ca O I amo I I Cl ee Above 90 Blinking Faster How to use e 24 Note Your initial heart rate zones are calculated by your profile data When using the PS 500
4. A Go back to the previous screen How to use e 32 Bluetooth settings Pairing Enter the Bluetooth menu to pair with a smart device or PULSENSE View Note Make sure that the product is within one meter from the smart device Your smart device will need to be connected to the Internet to complete pairing mn Pairing Bluetooth Completed Un pair By this operation pairing information will be deleted from the PS 500 1 Delete pairing information from PS 500 Enter the Bluetooth menu and press the A Button 2 Delete pairing information from I PULSENSE View 1 Open the PULSENSE View 2 Go to the settings and pairing menu 3 Delete PS 500 3 Delete pairing information from your smart device Go to the Bluetooth menu of your smart device and delete the PS 500 How to use e 33 Pairing issues lt When using the product for the first time gt i Attach the PS 500 to the cradle to cancel the battery protection mode Enable Bluetooth communication on your smart device To check smart device compatibility follow this link www epson eu pulsense Ensure your smart device is connected to the Internet Remove any other PULSENSE product that could interfere with the Bluetooth communication Has the PS 500 already been un paired If not tap the screen twice to enter the menu and press the B Button to enter the Bluetooth menu Confirm your selection by pressing the A Button 2 Has the PS 50
5. A SALMON ties asictdoo System Requirement iii Contents Using this Device Safely Symbels inthis ManUali oll illa Notes on Using the Product and Components Notes on using the cradle Regulatory and Safety NOtiCes Set up and Basic Operation Things You Can Do With The Product ccccccccocccnncccconccnncncnnncos NICASUrng HeMSs ar elia The heart rate zone display i Whats IM he DOK aryna e O Sie oidos Operating buttons and fUNctions Getting Started To record your data How to cancel the battery protection mode Wearing the PS 500 Initial GontiguratioNi ascleo illo Smart device USM ccs seco lla PG SC siete ata een How to use Display Screen In Heart Rate Measurement Mode Display Screen Without measuring heart rate A dle Mena Navigatio sessi a Navigate in the MENU i Check your heart rate range in the fat burning zone Bluetooth SettiigS inpniontn an Abcendcas LED SCHINGS einer Vibration Setting S uri eo POWE DT A A A PWI E a a cates ye elie A alas Language Seti ion Other Functions Notification Settings iii Al tia ita 2 Contents e 4 Wake up Alastair a arids 40 A A MA 41 Maintenance 43 LOOKING af
6. Appendix e 47 Product Specification Device Specifications Specification PS 500 45mm x 35mm x 14mm Excluding sensor unit Size LxWxH 1 77in x 1 38in x 0 55in Excluding sensor unit Approx 44g 140 190mm 5 51in 7 48in Rechargeable Lithium lon 75mAh Battery Life Heart rate ON Approx 36hours depending on usage Recharge Time Approx 3 5hours from empty to full Cradle Specification Specification Operating Temperature Recharge update PS 500 data through PC Options specifications You can purchase the following optional extras AC adapter Specifications SFACO2 for Europe excluding UK and Ireland Model SFACO3 for UK and Ireland AC 100 240V 50 60H2 DC 5V 1 0A Appendix e 48 Troubleshooting This section explains how to solve problems that occur during use Caution on page 50 Problem Solving on page 51 Resetting the System on page 52 LT Contacting us on page 53 Troubleshooting e 49 Caution Clean the PS 500 regularly Wipe the product with a slightly moist soft cloth and then dry or use a soft brush Do not use the cradle or AC adapter if they are in any way damaged faulty or contaminated by foreign material such as dust water or dirt Do not use any adapter other than the specified adapter for charging If charging becomes unstable clean the contact points on the device and cradle with a damp cotton swab If device operations becomes unstable or if d
7. Button to change the display Privacy screen Displays time and date without showing heart rate value Steps Heart rate time and date Distance calculated by steps Heart rate and zone indicator How to use e 27 Display Screen Without measuring heart rate When heart rate measurement is disabled you can check your statistics on the screens below Press the B Button to change the display a 1123 kcal Time and date Calories burned 143 13123 Steps Steps Distance calculated by steps How to use e 28 Back light Tap the screen of the PS 500 once to turn the backlight on How to use e 29 Menu Navigation Tap the screen of the PS 500 twice to enter the menu PP aad Navigate in the menu Once in the menu press the B Button to navigate between the sub menus Press the A Button to enter a sub menu If you want to return to the time screen hold B button 10000000000 10000000000 VOOR I p How to use e 30 Zone Menu Bluetooth Menu Systems Menu ir Menu Bluetooth Back to Zone Menu LI page on 32 LI page on 33 Vibrate LI page on 36 Version Power OFF fo Back to LED Z page on 37 LF page on 36 How to use e 31 Check your heart rate range in the fat burning zone You can check in which heart rate range you have to be to enter the fat burning zone in the Zone menu Press the A Button once in the Zone screen A
8. Information sheet Options You can purchase the following optional extras Contact your local reseller for more information AC Adapter SFACO2 for Europe excluding UK and Ireland AC Adapter SFACO3 for UK and Ireland Set up and Basic Operation e 12 Operating buttons and functions Battery icon Bluetooth icon Vibration icon Contact Point A Button B Button LEDs nor 0000000000 A Button Start Stop heart rate measurement B Button Check recorded data Hold down B to return to the previous screen Contact Point Check that the contact points on the device are pointing up and match the contact marks on the cradle LEDs Blue amp Orange The LEDs on the PS 500 light up or flash to indicate the current heart rate zone If you set your target in PULSENSE View you can check your progress while the measure is displayed on the screen You can cycle through the measurement by pressing the B Button TAP Operation Tap the screen once to turn the backlight on Tap the screen twice to get into the main menu Set up and Basic Operation e 13 Icons Battery Icon Remaining Time 36 to 20hours 20 to 12hours 12 to 3hours 3 to Ohours Important Remaining time may vary depending on usage Bluetooth Icon This product communicates with the smart device via Bluetooth Smart technology While the product is connected to the smart device the Bluetooth icon will be displayed
9. PS Uploader icon e lt 4 Insert the cradle s USB cable into the USB port of your PC PS Uploader Ver 1 00 You need to set up a PULSENSE View account and follow the on screen instructions For users who For users who want to create have an account an account Help Copyright C Seiko Epson Corporation 2014 All rights reserved Set up and Basic Operation e 20 How to use This product measures heart rate and activity 24 hours a day tracking your steps distance calories sleep quality and heart rate across five zones helping you to make better lifestyle choices LY Heart rate measurement on page 22 ZT Menu Navigation on page 30 LT Language setting on page 37 How to use e 21 Heart rate measurement Operation buttons 10000000000 10000000000 LELIES I p 1 Attach the product to your wrist and press the A Button Heart rate detection will start and a progress bar will be displayed i EEE A Se F If the PS 500 cannot detect the heart rate within one minute the device will vibrate and an error message will be displayed If the device does not detect your heart rate within three minutes the product will vibrate for longer and an error message will be displayed The PS 500 will then stop the heart detection Press the A Button to start the heart rate detection again How to use e 22 If the heart rate can t be detected The following vibration if enabled
10. as shown below Bluetooth Icon Status displayed as shown below Bluetooth OFF Fast OOOO O Not connected to smart device Connected to smart device Vibration Icon When vibration is set to ON the below icon will be displayed on the time screen you change the vibration settings to a specific heart rate zone in PULSENSE View Set up and Basic Operation e 14 Getting Started To record your data Important To record your data it is necessary to register your device with the PULSENSE View PC or smart device application How to cancel the battery protection mode Important You need to charge the product when using it for the first time The product automatically turns on when being charged Make sure that charging is complete T Attach the PS 500 to the cradle 1 Hold the top and bottom of the cradle to open it as shown below 2 Make sure that the terminal on the PS 500 is facing up and then attach the cradle Set up and Basic Operation e 15 2 Charging the product 2 1 Using a PC Insert the cradle s into the USB port of your PC Please note that if you are connecting the cradle via a USB hub it may not charge In this case please connect directly to the USB port of the PC Note Some PC USB ports may not support the charging function 2 2 Using an AC adapter Connect the cradle with the AC adapter and then insert the AC adapter into the power socket We recommend using the sp
11. contact our service center A charging error is being Charge in a location with an operating displayed temperature of 5 to 35 C Can use the product while The product is water resistant to 3bar The swimming or diving product is not designed for swimming or diving Water Resistance The inside of the glass where pombpctaly clouding w not affect the product i i Use it as is If the clouding does not clear up the sensor is located is cloudy i after some time water may have entered the product Data transfer is not possible even though the product is Refer to the Bluetooth section in this manual Data Transfer connected to a smart device to resolve pairing issues Troubleshooting e 51 System Reset If device operations become unstable perform a system reset by connecting the product to the cradle Charging resets the system and returns the product to normal operation If this suggestion does not solve your problem check LI Problem Solving on page 51 Troubleshooting e 52 Contacting us Go to www epson eu pulsense for service contact details EPSON EUROPE B V Address Atlas Arena Azi building Hoogoorddreef 5 1101 BA Amsterdam Zuidoost The Netherlands Troubleshooting e 53 412830801 Troubleshooting e 54
12. overnight the heart rate zones will be adjusted according to your basal heart rate minimum heart rate You can check your real time heart rate updated every four seconds in the PULSENSE View app Swipe the tab located in the middle at the top of the screen to the bottom in order to display the real time meter How your heart rate measurement is being used The PS 500 continuously monitors your heart rate and uses this recording in addition to your body movement to calculate the individual activities in PULSENSE View We therefore recommend having the heart rate detection enabled all the time not only during exercise For more information go to the Help section within the PULSENSE View app How to use e 25 How to stop and resume heart rate measurement 1 Manual Operation 1 To stop measuring your heart rate press the A button 2 Confirm to stop heart rate measurement by pressing the A Button Note If the A Button was pressed accidentally it will return back to the time screen after 10 seconds You can also hold the B Button to return to the previous screen 2 Automatically stop heart rate measurement If you remove the PS 500 and no movement is detected the device will automatically enter the sleep mode How to use e 26 Display Screen In Heart Rate Measurement Mode While in the heart rate measurement mode you can check your real time heart rate data and statistics on the screens below Press the B
13. this Device Safely e 6 Notes on Using the Product and Components N marning Exercise according to your physical capabilities Stop exercising and consult your doctor if you feel unwell during exercise This product is a highly accurate sensor and able to measure your pulse rate However this is not a medical device If you have any concerns consult your doctor before using this product Do not keep your eyes on the device while exercising otherwise you could fall or cause a traffic accident Pay attention to your surroundings while using the device Do not use or store this product in the following environments lt may cause an electric shock or fire or the product may malfunction or be damaged Locations with very high or low temperatures or humidity Near volatile substances Sooty or dusty places Near a fire Near a strong magnetic field for example near a loudspeaker Do not disassemble this product and do not attempt to repair this product by yourself It may cause an electric shock or accident Do not leave this product within reach of young children AN caut ion To avoid the possibility of skin irritation or discomfort from wearing the PS 500 you must keep the skin under the band clean and dry at all times Do not allow water sweat dead skin or dirt to build up under the band Do not wear the product too tight If you feel any discomfort loosen the wristband or stop usage Avoid water sweat or dir
14. 0 already been deleted from PULSENSE View Delete the PS 500 from the pairing menu in PULSENE View 3 Has the PS 500 already been deleted in the Bluetooth settings of your smart device Delete the PS 500 from the Bluetooth menu in smart device Has Bluetooth communication been enabled on your smart device 5 To check smart device compatibility follow this link www epson eu pulsense Ensure your smart device is connected to the Internet Remove any other PULSENSE product that could interfere with the Bluetooth communication How to use e 34 LED Settings Press the B Button and select from TAP FLASH ON OFF and press the A Button About the LED pattern see Heart rate zones page on24 How to use e 35 Vibration settings To Vibrate ha py Press the B Button to select ON or OFF press A to Vibrate ON de Power Off ME Power off Turn off PS 500 Power off Domo Back to the previous screen Hold down B To turn the PS 500 on again Press A or B Attach the product to the charging cradle Note Even if not used the product should be charged at least once within a 6 month period Failing to do so might affect the performance of the rechargeable battery How to use e 36 Firmware Mn Version n System Version sons B Language setting The following languages are supported Japanese English French German and Traditional Chinese
15. EPSO EXCEED YOUR VISION PS 500 Series User s Manual Introduction Thank you very much for purchasing a PS 500 To use the device correctly make sure you read the User s manual along with the supplied Quick Start Guide Keep the supplied Quick Start Guide handy to help you resolve any problems Description in the User s Manual Indicates things you must or must not do Ignoring these instructions or mishandling this device could cause malfunction or operational problems to the device Indicates additional explanations and related information Indicate related pages Click the link in blue text to display the related page Trademarks EPSON and EXCEED YOUR VISION are registered trademarks of the Seiko Epson Corporation Microsoft and Windows are registered trademarks of the Microsoft Corporation in the United States of America and other countries The Bluetooth word mark and logos are the registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Seiko Epson Corporation is under license Other product names are the trademarks or registered trademarks of their respective companies Caution Unapproved copying of part or all of this manual is strictly forbidden The content of this manual is subject to change without prior notice Although every effort has been made to ensure the accuracy of this manual contact us if you have any questions or notice any errors in descriptions in the c
16. ata transfer is not possible perform a system reset by connecting the product to the cradle Exercise according to your physical capabilities Stop exercising and consult your doctor if you feel unwell during exercise During sleep and in other situations your wrist may swell loosen the band by one setting if it becomes tight We recommend to connect the PS 500 to your smart device or PC once a day Troubleshooting e 50 Problem Solving Check each item rem Solution Nothing on the display After buying the product the PS 500 is in battery protection mode Set product to the cradle and connect to a USB port to charge the device and terminate the battery protection mode Basic Action LI Getting Started on page 15 The product is not responding Check the battery level and charge the device if according to the performed necessary operation The device does not charge Charge in an environment where the when set to the cradle surrounding temperature is 5 to 35 C Charging stops frequently Some PCs may not support the product If you are connecting the charging cradle via a USB hub it may not charge In this case please connect directly to the USB port of the PC Charging Clean the contact points of the product and charging cradle a ooking after your device on page 43 l The product or cradle might be faulty Luo produci and charging cradle Immediately stop using the product and cradle heat up while charging i and
17. ecified AC adapter SFACO3 for UK and Ireland SFACO2 for Europe excluding UK and Ireland Note Anorange LED will be shown while charging and the LED will change to blue when the PS 500 is fully charged Charging takes approximately 1 5 to 2 5 hours to complete however the duration may vary Important Please note that even if not used the PS 500 should be charged at least once within a 6 month period Failing to do so might effect the performance of the rechargeable battery The battery is not replaceable Set up and Basic Operation e 16 Wearing the PS 500 When wearing the product make sure it does not touch the bone on your wrist Wear the product closely around your wrist Tighten the wrist band if your pulse is not measured correctly while exercising Note Do not wear the product too tight If you feel any discomfort loosen the wristband During sleep your wrist may swell loosen the band by one setting if it becomes tight Set up and Basic Operation e 17 Initial Configuration Important You need to perform initial configuration before using PS 500 for the first time Create a PULSENSE View account and connect the device Smart device user 1 Search your smart device s app store for the dedicated application Epson PULSENSE View free and then install it Check that Internet communication and Bluetooth are enabled in your smart device Check the operating instructions for y
18. heart rate from the changes in light reflected through the blood vessels in your wrist Calories PULSENSE calculates the actual burned calories based upon the body motion and the heart rate information which is related very closely to the calories burned enabling more detailed calorie calculation When heart rate measurement is disabled the PS 500 will calculate calories based on body motion only Records the number of steps and calculates the distance using the accelerometer to measure your body movement This function enables you to consciously track your general activity so you can make small changes to become more active The distance is calculated approximately from the step count and your height Note Irregular arm movements may effect the reading on the steps and distance counters The heart rate zone display PULSENSE monitors your heart rate across 5 zones as detailed below This is displayed on LEDs on the device you can also set a vibration alert See How to Use section for details of max heart rate Below Aerobic Anaerobic Maximum Note Your initial heart rate zones are calculated by your profile data When using the PS 500 overnight the heart rate zones will be adjusted according to your basal heart rate minimum heart rate Set up and Basic Operation e 11 What s in the box Contact your reseller if there are any missing or damaged components 00000000 000000 Quick Start Guide
19. ontent of this manual Despite the preceding clause we cannot accept any responsibility of mishandling due to errors in this manual We cannot accept any responsibility for malfunctions and so on that occur due to ignoring the content of this manual the device being handled inappropriately repairs or modifications performed by a third party that is not our company of appointed by our company Introduction e 2 System Requirement A smart device such as a smart phone or tablet with Bluetooth Smart capability is needed to upload product recorded data Please check the below link for the latest compatibility www epson eu pulsense Note PS 500 has Bluetooth Smart to transfer data to PULSENSE View Uploaded data can be seen via PULSENSE View for Web URL go wellness epson com To upload your data from PS 500 Use the PULSENSE View for iOS Android on your smart device Your data will be transferred via Bluetooth Smart Use the PULSENSE View Web application on your PC by using the USB cradle Log into the PULSENSE View web application Log into PULSENSE View for iOS Android on your smart device Note To charge the PS 500 a USB port is required You can use the USB port of a PC or an AC adapter We recommend using the specified AC adapter SFACO3 for UK and Ireland SFACO2 Europe excluding UK and Ireland Introduction e 3 Contents Introduction Description in the User s Manual Ma
20. ote Try to keep your arm as still as possible If you move too much the screen will turn back to step 2 Other Functions e 41 4 Once the first bar is finished and Next is displayed tighten the wrist bar by one setting and repeat step 2 and 3 Other Functions e 42 Maintenance Looking after your device on page 44 Replacing the Battery on page 45 Updating the Firmware on page 46 Maintenance e 43 Looking after your device Clean the PS 500 regularly Wipe the product with a slightly moist soft cloth and then dry or use a soft brush Important Avoid water sweat or dirt build up between your skin and the product as it could lead to skin irritations About the wristband The wristband is made of silicon which could lose its elasticity and colour over time Maintenance e 44 Replacing the Battery You cannot replace the built in rechargeable battery Maintenance e 45 Updating the Firmware You may be able to solve problems that occur by updating the firmware We recommend using the latest version Important When updating the firmware the history may be deleted and settings may be initialised For more details on updating by smart device see the following website www epson eu pulsense Before updating the firmware we recommend uploading your measurement data to PULSENSE View via the app or PS Uploader Maintenance e 46 ry Product Specification on page 48
21. our smart device for the configuration method 2 Start Epson PULSENSE View Make sure that the product is within one meter from the smart device and battery is fully charged Note Set Bluetooth on your smart device to ON Ensure your smart device is connected to the Internet PULSENSE View Icon a EPSON Set up and Basic Operation e 18 3 You need to set up a PULSENSE View account and follow the on screen instructions PULSENSE View Password Forgot your password Create an account Epson Sensing ID Email Once you have created your account and completed your profile follow the on screen instructions to pair your PS 500 with your smart device Push B button display the bluetooth menu EE h D i gt en Q 0 Device pairing 4 Tap twice to display the menu ES Then push the A button to display gt the pairing screen lata vet f Device pairing E Device is paired OK let s begin Bluetooth Pairing Request Cae ee ANTAII PS 500 would like to pair with your iPhone PS 5 Cancel Pair You can see Complete on your PS 500 when pairing was successful Set up and Basic Operation e 19 PC User 1 Download PS Uploader from below address www epson eu pulsense Execute the downloaded file and run the installation After installing PS Uploader will open automatically You can see PS Uploader icon in the taskbar
22. t build up between your skin and the product Clean as directed in Looking after your device on page 44 During sleep your wrist may swell loosen the band by one seiting if it becomes tight Do not pour water directly from the tap onto this product The power of the tap water stream may be strong enough to compromise the product s waterproof feature Using this Device Safely e 7 N caut ion Do not wear this product in a bath or sauna The steam and soap may compromise the waterproof feature or cause corrosion Note Please note that even if not used the PS 500 should be charged at least once within a 6 month period Failing to do so might affect the performance of the rechargeable battery Notes on using the cradle Do not use the cradle or AC adapter if they are in any way damaged faulty or contaminated by foreign material such as dust water or dirt Do not use any adapter other than the specified adapter for charging Regulatory and Safety Notices CE Data communication between the smartphone and product is made by Bluetooth Low Energy which operates in the 2 4GHz band Hereby SEIKO EPSON declares that this PS 500 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC This equipment may be operated in the UK and Ireland Germany and France SEIKO EPSON CORPORATION 3 3 5 Owa Suwa shi Nagano Ken 392 8502 Japan E A Using this Device Safely e 8
23. ter YOU FUSVICOS iS 44 ADOULINSWAS DANA a a a 44 Replacing the Bate ii A ia 45 Updating the Fimware Lai 46 Appendix 47 Produet specliicalioni a eri lla nile 48 DeviceSpecificalionsa isla 48 CradiesSpecilicali0 sranie 48 Oprions specificalions caio 48 Troubleshooting 49 A celibe iene 50 Proben SONNO a belli 51 SA A A ed act tae 52 6779 1172 01 a6 US A E A A 53 Contents e 5 Using this Device Safely Make sure you read the manuals Quick Start Guide and User s manual first to use this product safely The product may malfunction or an accident may occur if it is handled incorrectly Keep the manuals handy to help you resolve any problems When taking this product out of the country of purchase check the laws and regulations in the destination country before you travel This product is not a medical device Use this product as an indicator during physical exercise Symbols in this Manual The following symbols are used in this manual to indicate possible dangerous operations or handling Make sure you understand these warnings before using the product N warn Ing This symbol indicates information that if ignored could possibly result in serious personal injury N caut lon This symbol indicates information that if ignored could possibly result in personal injury or damage the product This symbol indicates an action that should be done This symbol indicates an action that must not be done Using
Download Pdf Manuals
Related Search
Related Contents
Royaume du Maroc LCD10000VH_m01(PDF形式・3.2MB) Brother MFC-8870DW Copier User Manual Módulo de comunicaciones DeviceNet LULC09 Manual del usuario Nouveautés avril-mai 2014 Philips Clock Radio AJ100 Copyright © All rights reserved.