Emerson H800 Installation Guide
Contents
1. To avoid such injury and damage install the backpressure regulator in a safe location Clean out all pipelines before installation of the backpressure regulator and check to be sure the backpressure regulator has not been damaged or has collected foreign material during shipping For NPT bodies apply pipe compound to the male pipe threads For flanged bodies use suitable line gaskets and approved piping and bolting practices Install the backpressure regulator in any position desired unless otherwise specified but be sure flow through the body is in the direction indicated by the arrow on the body Note It is important that the backpressure regulator be installed so that the vent hole in the spring case is unobstructed at all times For outdoor installations the backpressure regulator should be located away from vehicular traffic and positioned so that water ice and other foreign materials cannot enter the spring case through the vent Avoid placing the backpressure regulator beneath eaves or downspouts and be sure it is above the probable snow level Overpressure Maximum inlet pressures depend upon body materials and temperatures Refer to the nameplate for the maximum inlet pressure of the valve The valve should be inspected for damage after any overpressure condition Fisher backpressure regulators are NOT ASME safety relief valves Startup The backpressure regulator is factory set at approximately the midpoint of
2. the spring range or the pressure requested so an initial adjustment may be required to give the desired results With proper installation completed and relief valves properly adjusted slowly open the upstream and downstream shutoff valves if applicable Adjustment To change the outlet pressure remove closing cap or loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure Monitor the outlet pressure with a test gauge during the adjustment Replace closing cap or tighten the locknut to maintain the desired setting S EMERSON Process Management D100405XENG Type H800 Table 1 Maximum Allowable Inlet Pressure to 67 Series Regulators with Type H800 Backpressure Regulator to prevent Instrument Supply Pressure From Exceeding 50 psig 3 4 bar MAXIMUM ALLOWABLE INLET PRESSURE TO SUPPLY PRESSURE REGULATOR TYPE H800 INSTALLATIONS A 67 67R 67F 67FR 67AF Yes or 67AFR No SUPPLY PRESSURE 1 REGULATOR TYPES REMOTE VENT PIPING Yes 67 67R 67AF or 67AFR No Yes 67FR or 67F 1 Limit vent piping to 30 equivalent feet 9 equivalent meters of 1 2 inch piping Lower vent piping may reduce the maximum allowable inlet pressure to supply pressure regulator Parts List Key Description Key Taking Out of Service Shutdown Description MN WARNING 6 Disc Restriction 1 Relief Valve Body To avoid personal injury resulting from sudden
3. Installation Guide English May 2002 Introduction This installation guide provides instructions for installation startup and adjustment To receive a copy of the instruction manual contact your local Fisher Sales Office or Sales Representative or view a copy at www emersonprocess com regulators For further information refer to Type H800 Instruction Manual form 5187 D100405X012 P E D Categories This product may be used as a pressure accessory with pressure equipment in the following Pressure Equipment Directive 97 23 EC categories It may also be used outside of the Pressure Equipment Directive using sound engineering practice SEP per table below PRODUCT SIZE CATEGORIES FLUID TYPE Specifications End Connections DN 6 1 4 inch NPT female Vent Connection DN 15 1 2 inch NPT female Maximum Allowable Control Pressure 17 2 bar 250 psig Pressure Range Non adjustable start to discharge between 2 7 and 3 0 bar 39 and 44 psig Reseat Pressure 2 4 bar 35 psig or higher Proof Test Pressure All Pressure Retaining Components have been proof tested per Directive 97 23 EC Annex 1 Section 7 4 Material Temperature Capabilities 20 to 150 F 29 to 66 C Installation Only qualified personnel should install or service a backpressure regulator Backpressure regulators should be installed operated and maintained in accordance with international and applicable codes and regulations and Fis
4. her instructions If using a backpressure regulator on a hazardous or flammable fluid service personal injury and property damage could occur due to fire or explosion of vented fluid that may have accumulated To prevent such injury or damage provide piping or tubing to vent the fluid to a safe well ventilated area or containment vessel Also when venting a hazardous fluid the piping or tubing should be located far enough away from any buildings or windows so to not create a further hazard and the vent opening should be protected against anything that could clog it 1 The pressure temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded www emersonprocess com regulators Type H800 Personal injury equipment damage or leakage due to escaping fluid or bursting of pressure containing parts may result if this backpressure regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section or where conditions exceed any ratings of the adjacent piping or piping connections To avoid such injury or damage provide pressure relieving or pressure limiting devices as required by the appropriate code regulation or standard to prevent service conditions from exceeding limits Additionally physical damage to the backpressure regulator could result in personal injury and property damage due to escaping fluid
5. release 2 Spring Case Screen 7 l of pressure isolate the backpressure regulator from 3 Spring 8 Internal Retaining Ring all pressure before attempting disassembly 4 Spring Cap 7 Machine Screw 5 Diaphragm 11 Diaphragm Disc ACTUATOR YOKE PNEUMATIC INSTRUMENT x TYPE 67AFR REGULATOR TYPE H800 tie BACKPRESSURE REGULATOR ESR INLET PRESSURE tg TUBING TUBING FOR INSTRUMENT VENT CONNECTION SUPPLY PRESSURE ACTUATOR YOKE ACTUATOR YOKE PNEUMATIC TYPE 67AFR REGULATOR INSTRUMENT TYPE H800 BACKPRESSURE L REGULATOR Ea PIPE PLUG MAY ALSO BE OPTIONAL GAUGE VENT CONNECTION INLET PRESSURE TUBING TUBING FOR INSTRUMENT SUPPLY PRESSURE 26A9059 B W3616 Figure 1 Typical Installation Orientations Industrial USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5856 Outside U S 1 469 293 4201 Asia Pacific Shanghai China 201206 Tel 86 21 5899 7887 Europe Bologna Italy 40013 Tel 39 051 4190611 A2908 Natural Gas Technologies USA Headquarters McKinney Texas 75070 Tel 1 800 558 5856 Outside U S 1 469 293 4201 Asia Pacific Singapore Singapore 128461 Tel 65 6777 8211 Europe Bologna Italy 40013 Tel 39 051 4190611 Gallardon France 28320 Tel 33 0 2 37 33 47 00 Figure 2 Type H800 Backpressure Regulator Industrial High Purity TESCOM Elk River Minnesota 55330 USA Tel 1 763 241 3238 Selmsdorf Germany 23923 Tel 49 0 38823 31 0 For f
6. urther information visit www emersonprocess com regulators The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls Inc a business of Emerson Process Management The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser N EMERSON Fisher Controls International Inc 2002 All Rights Reserved Process Management