Home
Emerson CF552GBZ00 User's Manual
Contents
1. Reinstall the hanger ball Figure 10 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble Ah WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling 44 WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling CEILING COVER Figure 10 NO y Meo 16 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 17 You have now completed the assembly of your new ceiling fan You can now proceed with 6 hanging and wiring your fan Figure 8 How to Hang Your Ceiling Fan Ah WARNING The fan must be hung with at least 7 of clearance from floor to blades
2. One pendant coupler Im 20 ro Oo o gt A ON oo 7 Three wire connectors 8 Two threaded studs 9 Two knurled knobs 10 Two lockwashers 11 One clevis pin 12 One hairpin clip 13 One balance kit NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly FAN BLADES BRACKET SWITCH HOUSING ASSEMBLY FAN MOTOR ASSEMBLY HANGER BALL DOWNROD ASSEMBLY V Ce HANGER EN CEILIN BRACKET Bul COVER U L Model No CF552 il gt S uem Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds A WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may
3. electrical wires and possible shock or fire hazard Ah WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket NOTE CEILING COVER Qum ctim SUPPLY WIRES AND EL Uc FAN WIRES OMITTED a ge De a n ABX FOR CLARITY HANGER BRACKET Figure 13 HANGER BALL DOWNROD ASSEMBLY U L Model No CF552 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before attempting installation NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied BLACK AND BLUE cnouwp PANWIRES WIRE LISTED WIRE WHITE SUPPLY CONNECTOR 3 Y NEUTRAL l ges HANGER BRACKET wee GREEN WIRE BLACK SUPPLY GROUND FROM HOT HANGER BALL NOTE CEILING COVER Figure 14 OMITTED FOR CLARITY NOTE If you are using an Emerson Light Fixture with your fan see Light Fixtu
4. SWITCH HOUSING ADAPTER x 10mm SERRATED CLOCKWISE TO ENGAGE TWO KEYHOLE PAN HEAD SCREW OLTEN N M4 x 10mm SERRATED PAN HEAD SCREWS 8 Engage the connector of the switch housing assembly with the motor connector Figure 5 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 9 Remove the three mounting screws from the bracket switch housing assembly Figure 5 SWITCH HOUSING dp SWITCH HOUSING CONNECTOR MOTOR CONNECTOR SWITCH HOUSING 10 Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three M4 x 12mm flat head screws supplied Figure 6 To avoid possible fire or shock do not pinch wires between the switch housing assembly and the bracket switch housing assembly SWITCH HOUSING ASSEMBLY AN NN FLAT HEAD SCREW 3 Figure 6 N Se 11 Carefully turn partially assembled fan upside down and place in styrofoam form carton in preparation for final installation U L Model No CF552 12 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 7 Remove the pin from the downrod then remove th
5. WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort
6. need to be replaced Consult a qualified electrician if in doubt If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Ah WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before attempting installation All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock Ah WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician How to Put Your Ceiling Fan Together 1 One by one unscrew each screw and discard screw and shipping retainer Figure 1 LL ADAPTER PLATE KO FROM THE ADAPTOR LATE CUM LU NC 2 Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws Figure 2 NOTE Take care not to scratch fan housing when installing blades M5x6mm WASHER Gi HEAD BLADE SCREW E 3 per blade flange FAN BLADE BLADE FLANGE Figure 2 3 Loosely attach one blade flange assembly to the motor hub by securing the two M6 x 14mm captive pan head screws Make sure the screws are NOT tightened Figure 3 Repeat this procedure for other four b
7. on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional mounting accessories Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy A WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start Fuse or circuit breaker bl
8. CEILING Uh te COVER THREADED xe LOCKWASHERS STUDS 2 2 KNURLED pere cms KNOBS 2 Figure 15 Ah WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 6 Cut the 3 speed switch pull chain to a desired length optional Connect the die cast pendant supplied to the 3 speed switch pull chain by sliding the die cast pendant small hole first onto the pull chain Attach the chain coupling to the end of the chain and allow the die cast pendant to fall down over the coupling U L Model No CF552 Using Your Ceiling Fan Maintenance 1 Restore electrical power to the outlet box by turning IMPORTANT CARE INSTRUCTIONS the electricity on at the main fuse box for your Ceiling Fan 2 Check the operation of the fan by gently pulling on the pull chain switch 3 All fans are shipped from the factory with the Periodic cleaning of your new ceiling fan is the only maintenance that is needed reversing switch positioned down to circulate air When cleaning use only a soft brush or lint free cloth downward If airflow is desired in opposite to avoid scratching the finish direction turn your fan OFF and wait for the blades to stop turning then slide the reversing switch to Abrasive cleaning agents are not required and should the up position and turn fa
9. Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Electric Co e Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when The original purchaser or user ceases to own the product or The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of us
10. Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This product is suitable for use in wet locations when installed in a GFCI protection branch circuit WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Sub
11. Figure 11 ICEN EE AT LEAST SE FLOOR ZE Figure 11 A WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support Ah WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 FUN OUTLET 1 Vd AT NOTE CEILING COVER i he Td BOX OMITTED FOR CLARITY TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET Figure 12 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 13 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 12 A WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall A WARNING Failure to seat tab in groove could cause damage to
12. If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration Fan motor assembly One switch housing assembly Oneceiling cover Five blade flanges One hanger ball 4 5 downrod assembly One hanger bracket One coupling cover Five fan blades One bracket switch housing assembly One loose parts bag containing 1 Sixteen M5 x 6mm washer head blade screws One M4 x 12mm flat head screw One M6 x 14mm pan head screw with lockwasher One M4 x 10mm serrated pan head Screw One die cast pendant
13. READ AND SAVE THESE INSTRUCTIONS CARRERA VERANDA 52 Ceiling Fan Wet Location Owner s Manual Model Numbers CF552AWOO0 Summer White CF552GBZ00 Gilded Bronze CF552GES00 Golden Espresso CF5520RBO0 Oil Rubbed Bronze CF552WBOO Weathered Bronze Net Weight 21 60 Lbs cont Part No F40BP73930001 Form No BP7393 1 U L Model No CF552 Ah WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must be in accordance with the National Electrical Codes ANSI NFPA 70 1999 and Local Electrical Codes Use the National
14. e Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73930001 Printed in China 07 09 Form No BP7393 1 U L Model No CF552
15. e hanger ball Retain the pin and hanger ball for reinstallation in Step 15 PIN HANGER BALL SN DOWNROD Figure 7 sd SETSUREW 13 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 8 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in the motor coupling Check that the lower setscrew is tightened securely Figure 8 NOTE The setscrews must be properly installed as described above or fan wobble could result 14 Figure 9 15 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 9 CEILING COVER DOWNROD COUPLING COVER
16. ecurely in the motor coupling Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade flanges to the motor are tight Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation U L Model No CF552 Repair Parts Listing Description Hanger Ball Assembly Consisting of Hanger Bracket Hanger Ball Downrod 4 5 CF552AW00 761655 21 CF552GBZ00 761655 77 Model Numbers CF552GES00 761655 35 CF5520RB00 761655 32 CF552WB00 761655 86 ONO HUON Parts Bag Containing Wire Connector 3 Pin Clevis Clip Hairpin Screw Flat Head M4 x 12mm 1 Screw Pan Head M6 x 14mm with Lockwasher 1 Screw Washer Head M5 x 6mm 16 Screw Serrated Pan Hd M4 x 10mm 1 Die cast Pendant Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Coupler Pendant Balancing Kit 1 763913 3 763913 3 763913 3 763913 3 Canopy Ceiling 1 Wiring Harness 1 Switch Housing 1 Coupling Cover 1 Flange set of 5 Blade set of 5 Switch Housing Adapter C
17. lade assemblies Ah WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades U L Model No CF552 4 The blade flanges have an interlocking feature that must be fully engaged before tightening the screw Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again REMOVE ONE M4 x 10mm SERRATED PAN HEAD SCREW AND LOOSEN THE OTHER TWO SCREWS a B BLADE FLANGE ASSEMBLY M6 x 14mm CAPTIVE PAN HEAD SCREW 2 per blade flange assembly Figure 3 5 Remove and retain one of the three M4 x 10 mm serrated pan head screws from the adapter plate Figure 3 Loosen the other two serrated head screws three or four turns 6 Position the bracket switch housing assembly on the adapter plate so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover 7 Turn the bracket switch housing assembly clockwise and tighten both screws Figure 4 Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly REINSTALL ONE M4 ROTATE
18. n on again be avoided to prevent damage to finish 4 The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows A WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock SX CIT A Three Speed 1st Pull HIGH 2nd Pull Medium Accessories 3rd Pull Low SWIZZ Ath Pull OFF S SS z 1 Ceiling Fan Light Kits see store or catalog se Fa 2 Ceiling Fan Light Controls see store or catalog SWITCH 3 Downrod Extension Kits see store or catalog Reverse Switch Information 4 Ceiling Fan Blades see store or catalog WARNING Summer Counter Clockwise Down Winter Clockwise Up The use of any other control not specifically approved for this fan could result in fire shock and personal injury Ah WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 9 U L Model No CF552 Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily
19. over Assembly Owner s Manual 763921 AW 763912 3 763919 AW 763922 AW 763930 AW 763917 AW 763915 AW BP7393 1 763921 GBZ 763912 3 763919 GBZ 763922 GBZ 763930 GBZ 763917 GBZ 763915 GBZ BP7393 1 763921 GES 763912 3 763919 GES 763922 GES 763930 GES 763917 CH 763915 GES BP7393 1 763921 ORB 763912 3 763919 ORB 763922 ORB 763930 ORB 763917 ORB 763915 ORB BP7393 1 763921 WB 763912 3 763919 WB 763922 WB 763930 WB 763917 WB 763915 WB BP7393 1 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 11 U L Model No CF552 LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for thirty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE
20. own Loose power line connections to the fan or loose switch wire connections in the switch housing Reversing switch in neutral position Check main and branch circuit fuses or circuit breakers Check line wire connections to fan and switch wire connections in the switch housing WARNING Make sure main power is turned OFF Make sure reversing switch position is all the way to one side 2 Fan sounds noisy Blades not attached to fan Loose screws in motor housing Screws securing fan blade flanges to motor hub are loose Wire connectors inside switch housing rattling Screws holding blades to flanges are loose Attach blades to fan before operating Check to make sure all screws in motor housing are snug not over tight Check to make sure the screws which attach the fan flanges to the motor hub are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF Tighten screws securely 3 Fan wobbles excessively Setscrew in hanger ball downrod assembly is loose Screws securing fan blade flanges to motor are loose Fan blade flanges not seated properly Hanger bracket and or ceiling outlet box is not securely fastened Fan blades out of balance Setscrew in motor coupling is loose Tighten both setscrews s
21. re Owner s Manual for wiring 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 14 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 14 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue ungrounded conductors on the other side of the outlet box Ah WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 15 5 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 15 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch s URS
22. stitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep itin a safe place for future use 2 U L Model No CF552 THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES PATIOS AND DECKS USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on Tools Needed for Assembly One stepladder One Phillips head screwdriver One wire stripper Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size proper method of wiring your fan page 8