1. USER MANUAL STORAGE WATER HEATER EWH eco R RN EWH R RN EWH SL SLN EWH S SN Y Electrolux CE INSTALLATION This electric unvented storage water heater includes the basic installation elements which are found in the packaging i e Insulating bushing for pipes Safety valve Installation and first operation of the storage heater and the fittings have to be done by an expert which can take the responsibility for properly done work and explains the handling procedures For the connection the specific technical conditions of the energy supplier as well as the valid standards and safety regulations have to be considered WALL MOUNTING PROCEDURE Use 4 adequately resistant and sturdy screws and rawl plugs capable of holding the weight of the filled heater LOCATION The installation procedure is greatly facilitated by the possibility to locate the unit horizontally EWH SL SLN and EWH R RN or vertically in a frost free place anywhere the house lt would be a good idea to place the unit as close as possible to the outlet short piping means little loss of temperature A minimum space of 50 cm below the outlet pipe is necessary for servicing As shown in the drawing the input and output pipes must be on the left side when the heater is installed horizontally Should the unit be close to a wall leave the recommended minimum space for maintenance and service Do not install the heater with its wall mounts
2. a i E Hot water da 6 IE o i oy l c L Safety 2 valve ors FE E Cold water 50cm Hot water ee Cold water Min 20 mm air inlet 1 Safety valve 2 Turning knob for cleaning and draining 3 Draining pipe for the safety valve 4 Stop valve 5 Reducing valve necessary when pressure is more than 5 bar to be installed after the meter 6 Earthed plastic sleeves supplied with the heater ELECTRIC INSTALLATION All storage water heaters of the EWH series are of 220 230 V single phase design Before connecting make sure that the mains supply and unit input features coincide The heaters installation procedure is totally straightforward and only requires that Low Voltage Electronic Regulations are met Although well known by the installers we would like to point out some of the basics The following volumes and provisions shall be taken into account for installations in bathrooms or toilets PROHIBITED VOLUME It is the volume limited by the tangential and vertical planes with respect to the outer edges of bathtub toilet pan or shower enclosure and by a plane situated 2 25 m above the same or the floor should the units be embedded in the same Safety valve Safety valve ECO Safety valve PROTECTION VOLUME It is the volume situated within the horizontal planes previously stated for the prohibited volume plus another two vertical ones 1 00 meters away
3. against the floor nor on a horizontal plane HYDRAULIC INSTALLATION The heater must be connected to the water supply mains a The safety valve supplied with the heater MUST be installed on the cold water input see right side Before connecting the safety valve with the heater the connecting pipe must be rinsed carefully The draining pipe and the safety valve must be left open to the air and be installed in a continuous downward slope Water expands when heated The units of the series R eco R and SL are supplied with a safety valve that lets the expanding water flow back into the cold water feed The units of the series RN and SLN have a safety valve that prevents the expanding water N non return from flowing back into the cold water feed Here a suitable siphon for the absorption of the expanding water is to install The drain of the safety valve must not be blocked To open the safety valve not safety valve eco to let the water flow from the heater via the outlet turn the knob clockwise or counterclockwise as you please The proper operating of the safety valve should be tested periodically that way turn the knob clockwise or counterclockwise up to the top position the water should flow out of the passage turn the knob to its down position The pressure rating is indicated on the knob b If the water supply pressure exceeds 5 bar a type approved reducing valve must be installed
4. certain amount of water has been used Setting water temperatures In the case of top range models the external control knob allows water temperature adjustments between 30 C min setting and 70 C max setling E Position Energy saving the water reaches a temperature of approx 55 C thus allowing the heater to operate economically Heat losses are minimal and calcareous deposits are practically fully eliminated Heating element power setting switch The deluxe and super deluxe models incorporate double power rating features and a switch for power setting changes Pos Il W MAX Total power Pos I MIN Minimum power lt is advisable to have the heater plugged into the mains permanently as the thermostat will only activate the unit when it becomes necessary to maintain the selected temperature settings How to empty the unit The heater should be fully drained if left unused for extended periods of time or if subject to freezing hazards where installed This can be done by means of the safety valve not safety valve eco Always remember Cut off the power supply Shut off the inqut cock Open the hot water tap MAINTENANCE The heater does not require a special maintenance procedure Clean by wiping with a soft cloth or damp sponge Never use abrasives nor detergents The customer is advised to contact the AFTER SALES SERVICE to check the magnesium bar once the guarantee has expired Although this particu
5. from those of the said volume No switches power sockets or lighting equipment must be installed within the PROHIBITED volume Do not install switches within the PROTECTION volume this does not apply however to safety power sockets If possible the heater must be installed outside the PROHIBITED VOLUME so as to prevent water splashing against the unit Power must be supplied via a multi polar switch circuit breaker or contactor Adequate power rating fuses shall be made available for unit protection purposes All electrical installations shall incorporate an earthing connection The plug used by the heater already has this connection and only has to be inserted in a mains socket of the same features Make sure the household or place of installation does have an earth line If not available a differential switch is recommendable The electric connection must be made with a power cable Type HO5VVF 3x1 5 Serie eco R RN OPERATION Filling up Open the shutoff cock as soon as the heater has been installed Open the hot water taps Water appears as soon as the unit fills up completely Close the laps and check the system for leaks Do not connect the heater to the power mains if uncertain as to whether it is foll or not Electric connection Plug into the mains and press the main power input switch A light flashes when the heating element is activated on some models The thermostat re connects the heating element after a
6. lar operation is not covered by the guarantee as it does not imply unit servicing it does allow the wear rate of the bar to be monitored and to establish how soon it should be changed Moreover indefinite heater duration can be guaranteed EWH SL SLN EWH S SN Therm security Any overheating caused by thermostat failures is offset by the safety limiting device cutting both stages off and leaving the heater without power input If this happens contact our After Sales Service WARNING Never remove the lead cover without previously disconnecting the heater from the power supply THE MANUFACTURER reserves the right to modify the characteristics and specifications of all products wilhout prior notice Two heating elements Three heating elements Thermostat Therm A OOO Heating element B OO EWH eco R RN EWH R RN EWH 15S SN EWH eco R RN EWH R RN T07B017F6 F407B0200 ELECTRIC HEATER FEATURES MODELS CAPACITY POWER RATING HEATING TIME h DIMENSIONS mm N 230 V 65 C A50 C 1000 1000 2x800 EWH R RN 2x800 2x800 2x900 2x1200 800 1600 800 1600 2x900 EWH SL SLN 2x900 2x900 2x1200 EWH SL SLN WALL MOUNTING WATER HEATERS 15 litres ELECTROLUX Haustechnik GmbH Gutenstetter Strasse 10 D 980449 N rnberg GERMANY WEIGHT kg