1. INFRARED VENT FREE PROPANE LP GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL CGP10RLA WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re Do not store or use gasoline or other fer to this manual for correct flammable vapors and liquids in the vicinity installation and operational pro of this or any other appliance cedures For assistance or ad ditional information consult a WHAT TO DO IF YOU SMELL GAS qualified installer service Do not try to light any appliance agency or the gas supplier Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing property damage personal injury or loss of life WARNING This is an unvented gas fired heater It uses air oxy gen from the room in which it is installed Provisions for ad equate combustion and venti lation air must be provided Installation and service must be performed Refer to Air For Combustion by a qualified installer service agency or the and Ventilationsection on page gas supplier 4 of this manual This appliance may be installed in an afte
2. Install sediment trap in supply line as shown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly IMPORTANT Hold pressure regulator with wrench when connecting it to gas piping and or fittings Pressure ee Regulator Heater Cabinet Tee Joint Reducer Test Gauge Connection 1 8 NPT Plug Tap Tee Joint Pipe Nipple Cap Sediment Trap A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessory page 16 Continued 104275 9 PROPANE LP GAS HEATER INSTALLATION Continued CHECKING GAS CONNECTIONS A WARNING Test all gas pip ing and connections for leaks after installation or servicing Correct all leaks at once 2 4 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve Check all joints from propane LP sup ply tank to equipment shutoff valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak Correct all leaks at once AA WARNING Ne
3. 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check all other in ternal joints for leaks 7 Turn off heater see To Turn Off Gas To Appliance page 11 8 Replace front panel Equipment Open Shutoff E ae i Valve See c Closed Figure 14 Equipment Shutoff Valve Control Valve Location Propane LP o Supply Tank MM AONDE T Equipment Shutoff SEE Valve ure 14 Figure 15 Checking Gas Joints 10 OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING A WARNING If you do not fol low these instructions exactly a fire or explosion may result caus ing property damage personal injury or loss of life This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire
4. GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise aaa to the OFF position Shutting Off Burner Only pilot stays lit Turn control knob clockwise to the PILOT position EE MANUAL LIGHTING PROCEDURE 1 Remove front panel see Figure 10 page 8 2 Follow steps 1 through 5 under Light ing Instructions 3 With control knob pressed in strike match Hold match to pilot until pi lot lights 4 Keep control knob pressed in for 10 seconds after pilot is lit After 10 sec onds release control knob 5 Replace front panel PROPANE LP GAS HEATER INSPECTING BURNER Check pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 19 shows acorrect pilot flame pattern Figure 20 shows an incorrect pilot flame pattern The incorrect pilot flame is not touch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 20 e turn heater off see To Turn Off Gas to Appliance page 11 e see Troubleshooting pages 13 through 15 Pilot Burner Thermocouple Figure 19 Correct Pilot Flame Pattern Pilot Burner la Figure 20 Incorrect Pilot Flame Pattern Thermocouple BURNER FLAME PATTERN Figure 21 shows a correct burner flame pattern Figure 22 shows an incorrect burner flame pattern Ifburner flame pattern is incorrect as shown i
5. LP Gas Propane LP gas is odor less An odor making agent is added to pro pane LP gas The odor helps you detect a propane LP gas leak However the odor added to propane LP gas can fade Propane LP gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater AA WARNING Any changeto this heater or its controls can be dan gerous A WARNING Do not use any accessory not approved for use with this heater Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will re main hot for a time after shut down Allow surface to cool be fore touching Carefully supervise young chil dren when they are in the same room with heater Make sure grill guard is in place before running heater Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors If you smell gas e shut off gas supply do not try to light any appliance do not touch any electrical switch
6. do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 10 11 12 13 14 Heater shall not be installed in a bath room Always run heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monoxide may result This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 Keep all air openings in the front and bottom of heater clear and free of de bris This will insure enough air for proper combustion If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off have it serviced Do not run heater e where flammable liquids or vapors are used or stored e under dusty conditions Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture Do not use heater if any part has been under water Immediately call a quali fied service technician to inspect the room he
7. floor ceiling and joining wall AX WARNING Never install the heater inabathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater asa fireplace insert e in high traffic areas in windy or drafty areas A CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls CEILING 36 Minimum gro Minimum From Sides Of Heater ut TFF Right Left Side Side pra Minimum To M OOo ancoga Top Surface Of Carpeting Tile Or Other Combustible Material FLOOR Figure 4 Mounting Clearances As Viewed From Front of Heater IMPORTANT Vent free heaters add mois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Com bustion and Ventilation pages 4 through 6 A CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor e locate heater where moving vehicle will not hit it For convenience andefficiency
8. install heater e where there is easy access for operation inspection and service e in coldest part of room INSTALLING HEATER TO WALL Marking Screw Locations 1 Determine where you will locate heater AM WARNING Maintain minimum clearances shown in Figure 5 If you can provide greater clear ances from floor and joining wall D Mark two mounting screw locations on wall see Figure 5 e 10 7 8 Minimum To Maintain 6 Clearance 4 From Wall m7 3 4 Mounting Screw Locations 20 1 4 Minimum To Maintain 3 Clearance From Floor JOINING WALL FLOOR Figure 5 Mounting Screw Locations Continued PROPANE LP GAS HEATER INSTALLATION Continued Installing Two Mounting Screws Note Wall anchors and mounting screws are in hardware package The hardware pack age is provided with heater Attaching to Wall Stud Method For attaching mounting screw to wall stud 1 Drill hole at marked location using 9 64 drill bit Insert mounting screw into wall stud 3 Tighten screw until 1 16 space thick ness of penny is between screwhead and wall Attaching to Wall Anchor Method Follow instructions below to attach mount ing screws to hollow walls wall areas be tween studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 4 deep Fold wall anchor see Figure
9. position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes Inspect burner pilot for dust and dirt 3 Blow air through the ports slots and holes in the burner Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly see Figure 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Inlet Air Hole CABINET Air Passageways e Use a vacuum cleaner or pressurized air to clean Exterior e Use a soft cloth dampened with a mild soap and water mixture Wipe the cabi net to remove dust 104275 TROUBLESHOOTING Note For additional help visit DESA International s technical service web site at www desatech com Note All troubleshooting items are listed in order of operation OBSERVED PROBLEM OWNER S MANUAL AX WARNING Turn off heater and letcool before servicing Only a qualified service person should service and repair heater POSSIBLE CAUSE A CAUTION Never use a wire needle or similar object to clea
10. release ignitor button This will light pilot The pilot is attached to the front of burner If needed keep pressing ignitor button until pilot lights Piezo Ignitor Button Control Knob IGNITOR Figure 16 Control Knob In The OFF Position 104275 OWNER S MANUAL Note If pilot does not light refer to Troubleshooting pages 13 through 15 Also contact a qualified service person or gas supplier for repairs Until re pairs are made light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 10 seconds after lighting pilot After 10 seconds release control knob Note If pilot goes out repeat steps 3 through 7 Ignitor Electrode Pilot Burner Thermocouple Figure 17 Pilot pes TO SELECT HEATING LEVEL AX WARNING When running heater set control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result A CAUTION Do nottry to adjust heating levels by using the equip ment shutoff valve 1 Slightly press in control knob and turn counterclockwise M to the LOW or HIGH positions IMPORTANT Release downward pressure while turning control knob Control knob will lock at the desired position Control Knobs Burners morrm PILOT LOW morrm PILOT HIGH E OFF E Figure 18 Burner Patterns a TO TURN OFF
11. 0 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater and Fireplace Store 58 Halbe Lane Cape May Court NJ 08210 1110 609 390 9774 Parts Department Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All States 937 258 3721 OH 1 800 762 3426 Halco Enterprises 208 Carter Drive Unit 21 West Chester PA 19382 4500 610 430 7717 1 800 368 0803 www halcoenterprises com LA Porte s Parts amp Service 2444 N 5th Street Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 cuisales aol com PROPANE LP GAS HEATER ILLUSTRATED 22 PARTS Ea Ne 7 BREAKDOWN 18 CGP10RLA es x ODS PILOT 18 104275 OWNER S MANUAL PARTS LIST This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 16 of this manual CGP10RLA PART NUMBER DESCRIPTION 098304 01 Screw 10 x 3 8 099467 07 Front Panel Assembly 099318 03 Grill Guard 101108 01 Removable Speed Clip 099469 02 Reflector Assembly M15823 37 Screw Hex 8 x 1 4 099059 03 ODS Pilot Assembly 098514 01 Thermocouple 098594 01 Ignitor Electrode 099884 02 Burner Assembly 099056
12. 01 Injector 099390 02 Tubing Valve to plaque A 099387 05 Pilot Tubing Valve to pilot 099392 01 Tubing Valve to plaque B 099391 02 Tubing Regulator to valve 100432 01 Control Valve 099468 17 Cabinet Assembly 099415 13 Gas Regulator 098303 02 Screw 6 x 5 16 098508 01 Valve Retainer Nut 099393 02 Control Knob M11084 26 Screw 10 x 3 8 099818 01 Internal Tooth Washer 097159 04 Piezo Ignitor Service Kit 098271 03 Ignitor Cable PARTS AVAILABLE NOT SHOWN 099395 07 Control Position Label 1 100642 02 Assembly Hardware 1 4p pa aaa ono a pp a a a sa 104275 19 WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No Date Purchased Always specify model and serial numbers when communicating with the factory Wereserve the right to amend these specifications at any time without notice The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTY COMFORT GLOW VENT FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for two 2 years from the date of first purchase provided that the product has been properly installed operated and maintained in accordance with all applicable instructions To make a claim under this warranty the Bill of Sale or cancelled check must be presented This warranty is extended only to the original
13. 6 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For thin walls 1 2 or less insert red key into wall anchor Push red key to pop open anchor wings see Figure 7 IMPORTANT Do not hammer key For thick walls over 1 2 thick or solid walls do not pop open wings 5 Tighten two screws until 1 16 space thickness of penny is between screwheads and wall see Figure 8 Figure 6 Folding Anchor Thin Walls 1 4 to 1 2 thick ese Figure 7 Popping Open Anchor Wings For Thin Walls Thin or Thick Wall fi thick wall shown 1 1 6 space SQ mn Solid Wall Figure 8 Tightening Anchors Placing Heater on Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Slide heater down until screws are in small portion of slots Keyhole Slots Figure 9 Location Of Keyhole Slots On Back Panel Of Heater Removing Front Panel of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraight up on grill guard until it stops Grill guard will slide up about 1 4 3 Pull bottom of front panel forward then down Figure 10 Removing Front Panel Of Heater Pe ay Installing Bottom Mounting Screw 1 Locate bottom mounting hole This hole is near bottom on back panel of heater see Figure 11 Mark screw location on wall R
14. NSTALLATION NOTICE This heater is intended for use as supplemental heat Use this heater along with your pri mary heating system Do not in stall this heater as your primary heat source If you have a central heating system you may run system s circulating blower while using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heating source Ay WARNING A qualified ser vice person must install heater Follow all local codes CHECK GAS TYPE Use only propane LP If your gas supply is not propane LP do not install heater Call dealer where you bought heater for proper type heater INSTALLATION ITEMS Before installing heater make sure you have the items listed below e piping check local codes e sealant resistant to propane LP gas e equipment shutoff valve e ground joint union e test gauge connection e sediment trap e tee joint e pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an ac ceptable alternative to test gauge connec tion Purchase the optional CSA AGA de sign certified equipment shutoff valve from your dealer See Accessory page 16 104275 OWNER S MANUAL LOCATING HEATER This heater is designed to be mounted on a wall AX WARNING Maintain the mini mum clearances shown in Fig ure 4 If you can provide greater clearances from
15. ODS pilot see Cleaning and Maintenance page 12 or replace ODS pilot assembly 7 Replace gas regulator ODS pilot lights but flame goes out when control knob is released 104275 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple connection loose at con trol valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged www desatech com 13 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in 10 seconds 3 Fully open equipment shutoff valve 4 Hand tighten until snug then tighten 1 4 turn more 5 A Contact local propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 12 or replace ODS pilot assembly 6 Replace thermocouple 7 Replace control valve Continued PROPANE LP GAS HEATER TROUBLESHOOTING Continued OBSERVEDPROBLEM POSSIBLE CAUSE REMEDY Burner s does not light after ODS pilotis lit 1 Burner orifice s is clogged 1 Clean burner orifice s see Cleaning and Maintenance page 12 or replace burner orifice s 2 Burner orifice s diameter is too small 2 Replace burner orifice s 3 Inlet gas pressure is too low 3 Contact lo
16. amage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rain or sleet Propane LP External fw Regulator Vent a Pointing HEA L Down Figure 12 External Regulator With Vent Pointing Down OWNER S MANUAL A CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe 3 8 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur Installation mustinclude an equipment shutoff valve ground joint union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 IMPORTANT Install an equipment shutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves 3 8 NPT Pipe Nipple gt Ground Joint Union Equipment Shutoff Valve From External Regulator 11 W C to 14 W C Pressure 3 Minimum Figure 13 Gas Connection i ee to 1 8 NPT CAUTION Use pipe joint seal ant that is resistant to liquid pe troleum LP gas
17. ater and to replace any part of the control system and any gas control which has been under water Turn off heater and let cool before ser vicing Only a qualified service person should service and repair heater Operating heater above elevations of 4 500 feet could cause pilot outage To prevent performance problems do not use propane LP fuel tank of less than 100 Ibs capacity 104275 OWNER S MANUAL PRODUCT IDENTIFICATION Piezo Ignitor Button A Control Knob E d Grill Guard Burners Heater Cabinet Front Panel Figure 1 Vent Free Propane LP Gas Heater LOCAL CODES UNPACKING Install and use heater with care Follow all 1 Remove heater from carton local codes In the absence of local codes use 2 Remove all protective packaging ap the latest edition of the National Fuel Gas plied to heater for shipment Code ANS 2223 1 also known as NFPA 54 3 Check heater for any shipping damage Available from If heater is damaged promptly inform American National Standards Institute Inc Goaler where yoy DON ENA ENS 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 104275 3 PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff sys tem The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if the
18. cal propane LP gas company Delayed ignition of burner s Manifold pressure is too low Burner orifice s is clogged Contact local propane LP gas company Clean burner orifice s see Cleaning and Maintenance page 12 or replace burner orifice s Burner backfiring during combustion Burner orifice s is clogged or damaged Burner damaged Gas regulator defective Clean burner orifice s see Cleaning and Maintenance page 12 or replace burner orifice s Replace burner Replace gas regulator Burner plaque s does not glow Control knob set between locked positions Turn control knob until it locks at de sired setting 2 Inlet gas pressure is too low 2 Contact local propane LP gas company 3 Plaque damaged 3 Replace burner Slight smoke or odor during initial operation 1 Residues from manufacturing processes 1 Problem will stop after a few hours of operation Heater produces a clicking ticking noise just after burner is lit or shut off Metal expanding while heating or con tracting while cooling This is common with most heaters If noise is excessive contact qualified ser vice person White powder residue forming within burner box or on adjacent walls or furniture When heated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue www desatech com 14 Turn heater off when using furniture polish wax carp
19. ce provides an unconfined space remove door to adjoin ing room or add ventilation grills between rooms See Ventilation Air From Inside Building page 6 B Vent room directly to the outdoors See Ventilation Air From Outdoors page 6 C Install a lower Btu Hr heater if lower Btu Hr size makes room unconfined If the actual Btu Hr used is less than the maximum Btu Hr the space can support the space is an unconfined space You will need no additional fresh air ventilation Awarnine If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code ANS 2223 1 Section 5 3 or applicable local codes Continued 104275 5 PROPANE LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of venti
20. d Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 kg per pa sec m or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around win dow and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumb ing electrical and gas lines and at other openings If your home meets all of the three criteria above you must provide ad ditional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to De termining Fresh Air Flow For Heater Location page 5 Confined and Unconfined Space The National Fuel Gas Code ANS 2223 1 def
21. department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un der water 104275 OPERATING HEATER Continued EE LIGHTING INSTRUCTIONS 1 STOP Read the safety information page 10 column 3 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise 7 N to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation If you don t smell gas go to the next step 5 Press in control knob and turn coun terclockwise to pilot position Keep control knob pressed for five seconds Note You may be running this heater for the first time after hook ing up to gas supply If so the con trol knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system Ifcontrol knob does not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and
22. ecified heat propane LP gas supply may be low When Gas Quality Is Bad e pilot will not stay lit e burner s will produce flames and soot e heater will backfire when lit You may feel your gas pressure is too low or gas quality is bad If so contact your local propane LP gas supplier SERVICE PUBLICATIONS You can purchase a service manual from the address listed on the back page of this manual Send a check for 5 00 payable to DESA International 20 2x 13 2x 5 25 x 16 fie x 7 ACCESSORY Purchase this heater accessory from your local dealer If they cannot supply this ac cessory either contact your nearest Parts Central see page 17 or call DESA International s Parts Department at 1 800 972 7879 for referral information You can also write to the address listed on the back page of this manual EQUIPMENT SHUTOFF VALVE GA5010 Equipment shutoff valve with 1 8 NPT tap REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product If they cannot sup ply original replacement part s call DESA International s Customer Service Depart ment at 1 800 323 5190 for information When contacting your dealer or DESA In ternational have ready your name e your address e model and serial numbers of your heater e how heater was mal
23. emove heater from wall If installing bottom mounting screw into hollow or solid wall install wall anchor Follow steps 1 through 5 un der Attaching To Wall Anchor Method If installing bottom mounting screw into wall stud drill hole at marked lo cation using 9 64 drill bit 5 Replace heater on wall 6 Insert bottom anchor screw through back panel into bottom anchor or drilled hole see Figure 11 7 Tighten screw until heater is firmly se cured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connections and checking for leaks see pages 9 and 10 Figure 11 Installing Bottom Mounting Screw 104275 INSTALLATION Continued CONNECTING TO GAS SUPPLY AX WARNING This appliance re quires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator A WARNING A qualified ser vice person must connect heater to gas supply Follow all local codes Acaution Neverconnect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and propane LP supply The installer must supply an external regu lator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure between 11 and 14 inches of water Ifyou do not reduce incom ing gas pressure heater regulator d
24. enance page 12 Gas odor even when control knob is in OFF position Gas leak See Warning statement at top of page Control valve defective Locate and correct all leaks see Check ing Gas Connections page 10 Replace control valve Gas odor during combustion Foreign matter between control valve and burner Gas leak See Warning statement at top of page Take apart gas tubing and remove for eign matter Locate and correct all leaks see Check ing Gas Connections page 10 Moisture condensation noticed on windows 104275 Not enough combustion ventilation air www desatech com 15 Refer to Air for Combustion and Venti lation requirements page 4 PROPANE LP GAS HEATER SPECIFICATIONS Btu Variable 5 500 10 000 Type Gas Propane LP Only Ignition Piezo Pressure Regulator Setting 8 W C Inlet Gas Pressure inches of water Maximum 14 Minimum 11 Dimensions Inches H x W x D Heater Carton Weight pounds Heater 14 Shipping 18 TECHNICAL SERVICE You may have further questions about in stallation operation or troubleshooting If so contact DESA International s Technical Service Department at 1 800 323 5190 You can also visit DESA International s technical service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low e pilot will not stay lit e burner s will have delayed ignition e heater will not produce sp
25. et cleaners or similar products 104275 TROUBLESHOOTING Continued OWNER S MANUAL building A WARNING If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces unwanted odors 1 Ww N Heater burning vapors from paint hair spray glues etc see IMPORTANT statement above Low fuel supply Gas leak See Warning statement at top of page 1 Ww N Ventilate room Stop using odor causing products while heater is running Refill supply tank Locate and correct all leaks see Check ing Gas Connections page 10 Heater shuts off in use ODS operates Ww N Not enough fresh air is available Low line pressure ODS pilot is partially clogged Ww N Refer to Air for Combustion and Venti lation requirements page 4 Contact local propane LP gas company Clean ODS pilot see Cleaning and Maint
26. functioning e type of gas used propane LP or natural gas e purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they cannot supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready e model number of your heater e the replacement part number 104275 PARTS CENTRALS OWNER S MANUAL These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com 104275 Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 732 87
27. ines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggre gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are con sidered a part of the unconfined space This heater shall not be installed in a con fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only ifthere are doorless passageways or ventila tion grills between them 104275 OWNER S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height cu ft volume of space Example Space size 18 ft length x 16 ft width x 8 ft ceiling height 2304 cu ft volume of
28. lation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS 2223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Ventilation Grills Into Adjoining Room Ventilation Option 2 Grills Or into Adjoining Remove Room Door into Option 1 Adjoining Room ries eS Option 3 n CMM ff CITT iid Figure 2 Ventilation Air from Inside Building LEE Ventilated Attic Outlet fj Air To Attic E To Jo C rawl Space iii munn Air L Ventilated Inlet Air Crawl Space Figure 3 Ventilation Air from Outdoors 6 104275 I
29. n ODS pilot This can damage ODS pilot unit REMEDY When ignitor button is pressed and control knob is pressed in and turned to the PILOT position there is no spark at ODS pilot 1 Ignitor electrode positioned wrong 2 Ignitor electrode broken 3 Ignitor electrode not connected to igni tor cable 4 Ignitor cable pinched or wet 5 Piezo ignitor nut is loose 6 Broken ignitor cable 7 Bad piezo ignitor 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 6 Replace ignitor cable 7 Replace piezo ignitor When ignitor button is pressed and control knob is pressed in and turned to the PILOT position there is spark at ODS pilot but no ignition 1 Gas supply turned off or equipment shutoff valve closed 2 Control knob not in PILOT position Control knob not pressed in while in PILOT position 4 Air in gas lines when installed W n Depleted gas supply 6 ODS pilot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat igniting operation until air is re moved 5 Contact local propane LP gas company 6 Clean
30. n Figure 22 e turn heater off see To Turn Off Gas to Appliance page 11 e see Troubleshooting pages 13 through 15 Figure 21 Correct Burner Flame Pattern perp Figure 22 Incorrect Burner Flame Pattern CLEANING AND MAINTENANCE A WARNING Turn off heater and let cool before cleaning A CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a quali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc ODS PILOT AND BURNER ORIFICE e Use a vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow
31. re is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system requires no matches batteries or other sources to light heater PROPANE LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION AX WARNING This heater shall not be installed ina confined space or unusually tight construction unless provisions are provided foradequate combustion and ven tilation air Read the following in structions to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy effi cient than ever New materials increased insulation and new construction methods helpreduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide ad equate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANS Z223 1 Sec tion 5 3 Air for Combustion an
32. retail purchaser This warranty covers only the cost of part s required to restore this heater to proper operating condition Warranty part s MUST be obtained through authorized dealers of this product and or DESA International who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 2 YEARS FROM THE DATE OF FIRST PURCHASE AND DESA INTERNATIONAL S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES Some state
33. rmarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Save this manual for future reference PROPANE LP GAS HEATER SAFETY INFORMATION A WARNINGS Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies IMPORTANT Read this owner s manual carefully and completely before trying to assemble oper ate or service this heater Im proper use of this heater can cause serious injury or death from burns fire explosion and car bon monoxide poisoning Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater AX DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness and or nau sea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Propane
34. s do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state DESA INTERNATIONAL 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 104275 01 104275 01 NOT A UPC Rev C 02 00 For information about this warranty write
35. space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 2 Divide the space volume by 50 cubic feet to determine the maximum Btu Hr the space can support volume of space 50 cu ft Maximum Btu Hr the space can support Example 2304 cu ft volume of space 50 cu ft 46 1 or 46 100 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Example Gas furnace Btu Hr Gas water heater 40 000 Btu Hr Vented gas heater Btu Hr Vent free heater 10 000 Btu Hr Gas fireplace logs Btu Hr Total 50 000 Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the space can support Btu Hr actual amount of Btu Hr used Example 46 100 Btu Hr maximum the space can support 50 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra spa
36. ver use an open flame to check for a leak Apply a mixture of liquid soap and water to alljoints Bubbles forming show a leak Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Fig A CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater See guidelines under Con necting to Gas Supply page 9 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply pip ing system Pressures in excess of 1 2 psig will damage heater regulator Cap off open end of gas pipe where equipment shutoff valve was connected Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak Correct all leaks at once Reconnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Open propane LP supply tank valve A 3 Make sure control knob of heater is in the OFF position 4 Check alljoints from equipment shutoff B valve to control valve see Figure