Dell R520 White Paper
Contents
1. c cece ee eee eee 7 Figure 8 Disconnecting the CMA attachment NOUSINGS cece cece cece cece eee eeeeeeeeeeeeeeeeeenenenes 9 Figure 9 Replacing a hot swap power supply ssesssrerssresrsrrsrrrrsrrrrerrrrerrsrerrsrerrrrrerrrrerrerno 9 Figure 10 Cable routing on sliding rails without a CMA s sssesusnernsrerrsrerrnerrsrerrsrrrrrrrrrerrrrene 10 Figure 11 Removing the outer CMA brackets for shallow racks s esssrerrsrrrrerrsrerrrrrrrerrrrene 11 Figure 12 Cabling a system installed in static railS cece cece cece cece cece eens ee eeeeeeeeeeeeeeeeeenennnes 11 Cable Routing Procedures for the Dell PowerEdge R520 System Introduction This white paper covers recommended cable routing procedures for the Dell PowerEdge R520 system in the following racks e PowerEdge 2410 4210 e PowerEdge 2420 4220 4820 including wide and deep versions e PowerEdge Energy Smart 4020S 4620S If you are using the optional cable management arm CMA following these procedures will allow you to extend the system from the rack for service without powering down or disconnecting the cables If you are not using the CMA following these procedures will ensure secure attachment and strain relief of the cables behind the system For guidelines on how to route cables within the rack refer to the Dell Best Practices Guide for Rack Enclosure white paper For additional details regarding potential interferences between the CM
2. A and rear mount power distribution units PDUs in Dell racks as well as general information about third party rack compatibility refer to the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix located at http content dell com us en enterprise d business solutions engineering docs en Documents ail rack matrix pdf aspx Section 1 Cabling a PowerEdge R520 system with a CMA This section details how to cable the PowerEdge R520 system on sliding rails using a CMA If you are cabling the system without the optional CMA refer to Section 3 Follow the instructions contained in the Rack Installation Instructions in the sliding rail kit to install the server into the rack Once installed use these instructions to Install the cables All illustrations in the following sections were created using a PowerEdge R520 system NOTE The PowerEdge R520 system is backward compatible with the PowerEdge R510 rails and CMA 1 1 Connecting the cables to the system Attach the CMA tray to the back of the rails as described in the CMA Installation Instructions provided in the CMA kit Connect all applicable cables to the rear of the system and verify that all connections are secure See Figure 1 Cable Routing Procedures for the Dell PowerEdge R520 System 1 2 Routing the power cables through the strain reliefs After you have installed the tray and cables route the power cable s through the strain relief s located on the powe
3. Cable Routing Procedures for the Dell PowerEdge R520 System This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the R520 system Greg Henderson and J ose L Flores Data Center Infrastructure Engineering May 2012 Cable Routing Procedures for the Dell PowerEdge R520 System This document is for informational purposes only and may contain typographical errors and technical inaccuracies The content is provided as is without express or implied warranties of any kind 2012 Dell Inc All rights reserved Dell and its affiliates cannot be responsible for errors or omissions in typography or photography Dell the Dell logo and PowerEdge are trademarks of Dell Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell disclaims proprietary interest in the marks and names of others May 2012 Rev 1 0 Cable Routing Procedures for the Dell PowerEdge R520 System Contents PPE OCC ON a cose sees aN AEE E E arth EE dee ange earth an ee ee ee eae ee eee aes eons ae cette E ae 4 Section 1 Cabling a PowerEdge R520 system with a CMA cece cccee ee eee sence eee eeeeeeeeeeeeneeeees 4 Ll Connecting the cables to the system sserusreresrerrerrsrrrrsrrrrerrrrerrrrrrrsrrsrrrrrrrrrno 4 L2 Routing the power cables through the strain reliefS ccceeeeeeeeeeeeeee
4. eeeeeeeeeeeenenees 5 L3 hae aaa Ea S E A E E E E E EE 5 Section 2 Replacing a hot swap power supply on a PowerEdge R520 system with a CMA 5 8 2 1 Replacing a hot swap power supply with a left side mounted CMA cceeeeee seen eens 8 Jud Replacing a hot swap power supply with a right side mounted CMA cceeeee eee eens 8 Section 3 Cabling a PowerEdge R520 system on sliding rails without a CMA ccceeee neues 10 3 1 ROCIO CNS CID E enera EREA EE OA E EEE E E E EREE E EENET 10 3 2 Removing the outer CMA brackets for shallow racks cceceeeeee eee eeeeeeeeeeeeeeeeenees 10 Section 4 Cabling a PowerEdge R520 system installed on static railS ssssrererrrrrrerererrrrerern 11 Figures Foure d System With cables Matal Errina a AAEE A ar 4 Figure 2 Routing power cables through the strain reliefs on hot swap power supplies 05 5 Figure 3 Routing the power cable through the strain relief on a fixed power supply 0008 5 Figure 4 Attaching the inner CMA attachment bracket ccc cece cece cece ee eeeeeeeeeeeeeeeeeeeeeeeaes 6 Figure 5 Routing the cables through the CMA cccccccc eee e cece eee e eee e esse seeeeeeeeeeeeeeeneeeeennngs 6 Figure 6 _Left side mounted CMA installation preferred ccc ccc ccc cece cess eeeeeeeeeeeeeeeeeeeeeenaes 7 Figure 7 _ Right side mounted CMA installation CMA shown in Service POSITION
5. f desired 10 Cable Routing Procedures for the Dell PowerEdge R520 System Figure 11 Removing the outer CMA brackets for shallow racks Section 4 Cabling a PowerEdge R520 system installed on static rails NOTE The CMA is compatible only with the sliding rails not the static rails 1 Follow the instructions contained in the Rack Installation Instructions found in the static rail kit to install the server into a two post or four post rack 2 Install the hook and loop straps provided in the rail kit through the slots in the rear brackets of the rails as described in the Rack Installation Instructions 3 Connect all applicable cables to the rear of the system and verify that all connections are secure 4 Using the hook and loop straps bundle the cables and secure them to either the left rail or right rail as described in the Rack Installation Instructions See Figure 12 for an example of data cables secured to the left rail and power cables secured to the right rail as viewed from the rear of the system Figure 12 Cabling a system installed in static rails C Sssssses as H 1 11
6. g Procedures for the Dell PowerEdge R520 System Figure 4 Attaching the inner CMA attachment bracket 1 3 2 Left side mounting instructions 1 Install the CMA on the rear left side of the rails by attaching both CMA housings to the attachment brackets on the rails 2 Route the cables through the CMA while avoiding twisting the cables Use the hook and loop straps on the CMA to secure the cables 3 If the cable bundle includes a keyboard video and mouse system interface pod KVM SIP it can be placed inside the CMA basket when the CMA is mounted on the left side See Figure 5 NOTE Do not store excess cable Slack inside the CMA The cables may protrude through the CMA thus Causing binding and potentially damaging the cables Cables entering the CMA should have a Small amount of slack to avoid cable strain when the CMA is extended KVM SIP can be placed inside the basket when the CMA is mounted on the left side 4 Once you have routed all of the cables through the CMA dress the cable slack between the back of the system and the entrance of the CMA using the tie wraps provided in the CMA kit 5 Clip off the excess length of material from the tie wraps Make sure that the heads of the tie wraps are positioned so as to avoid interference with adjacent systems Return the CMA to the closed retracted position Cable Routing Procedures for the Dell PowerEdge R520 System 6 Extend the system out of the rack to verify
7. he CMA for the Dell PowerEdge R520 system is optional Without the CMA installed the system must be powered down and all cables disconnected before it can be extended out of the rack 3 1 Routing the cables 1 Connect all applicable cables to the rear of the system and verify that all connections are secure 2 Using the hook and loop straps supplied with the rail kit bundle the cables and secure them to either the left or right outer CMA attachment bracket as described in the Rack Installation Instructions See Figure 10 for an example of data cables secured to the left outer CMA bracket and power cables secured to the right outer CMA bracket as viewed from the rear of the system Figure 10 Cable routing on sliding rails without a CMA seeeeeaeecaeea seeeee i S e ee28eee0808868 _ o S888 8888 808808 eseeneen seaseee ce LS eeeeee8 m OS seeeee Seaeacenea a PrP nese ow eeeeee 3 2 Removing the outer CMA brackets for shallow racks If you are installing the system into a shallow rack less than 1 meter deep and you will not be installing a CMA the outer CMA brackets may be removed from the sliding rails if necessary in order to allow the rails to fit properly into the rack Remove the brackets by using a 2 Phillips screwdriver to remove the screws that secure the brackets to the rails as shown in Figure 11 Use the hook and loop Straps supplied with the rail kit to secure the cables to the rack frame i
8. nd return the CMA to the closed retracted position Replacing a hot swap power supply with a right side mounted CMA Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit If the bottom power supply is being replaced first remove the tray from underneath the CMA as described in the CMA Installation Instructions If the top power supply is being replaced the tray can remain in place Disengage the strain relief and disconnect the power cord from the power supply Disconnect both CMA attachment housings from the brackets on the rails as shown in Figure 8 Detach the inner CMA bracket from the rail by pushing on the end of the lock spring and lifting the bracket up and to the left until it clears the standoffs on the rail While supporting the CMA with one hand remove and replace the power supply with the other hand as shown in Figure 9 Reinstall the inner CMA bracket to the rail and reconnect the CMA to the brackets Plug in the power cord re engage the strain relief replace the CMA support tray if necessary and return the CMA to the closed retracted position Cable Routing Procedures for the Dell PowerEdge R520 System Figure 8 Disconnecting the CMA attachment housings Figure 9 Replacing a hot swap power supply Cable Routing Procedures for the Dell PowerEdge R520 System Section 3 Cabling a PowerEdge R520 system on sliding rails without a CMA NOTE T
9. r supply handle s as shown in Figures 2 amp 3 Figure 2 Routing power cables through the strain reliefs on hot swap power supplies g i i jai 4 ITITI lt ALLTTTT LITTTT a oa Sha t a on e a 1 3 Installing the CMA The CMA can be installed on either the rear right or rear left side of the rails as described in the CMA Installation Instructions Mounting the CMA on the side that is opposite of the power supplies left side mount is recommended for systems with hot swap power supplies otherwise the CMA must be partially disconnected in order to remove the outer power supply Refer to Section 2 for details on power supply replacement NOTE If you are installing fiber optic cables in the CMA a cable bend radius of at least 1 inch must be maintained throughout the length of the cable It is recommended that fiber optic cables be routed on the exterior of the cable bundle to increase the bend radius of the fiber optic cables through the CMA Additionally a large amount of slack at the entrance and exit of the CMA is recommended 1 3 1 Installing the inner CMA attachment bracket As described in the CMA Installation Instructions locate and attach the appropriate inner CMA attachment bracket based on which side you wish to mount the CMA Use the bracket marked A for mounting the CMA on the left side and the bracket marked B for mounting on the right side See Figure 4 Cable Routin
10. that there is sufficient slack in the cables on both ends of the CMA See Figure 6 for an example of a completed left side mounted CMA installation Figure 6 _Left side mounted CMA installation preferred See Gene eenaeeaee r t gt f frf 0 DS Ds 1 3 3 Right side mounting instructions Install the CMA on the rear right side of the rails by attaching both CMA housings to the attachment brackets on the rails The remaining steps are the same as for left side mounting as described in Section 1 3 2 See Figure 7 for an example of a completed right side mounted CMA installation Figure 7 Right side mounted CMA installation CMA shown in service position Cable Routing Procedures for the Dell PowerEdge R520 System Section 2 Replacing a hot swap power supply on a PowerEdge R520 system with a CMA bode 1 Replacing a hot swap power supply with a left side mounted CMA Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit If the bottom power supply is being replaced first remove the tray from underneath the CMA as described in the CMA Installation Instructions If the top power supply is being replaced the tray can remain in place Disengage the strain relief and disconnect the power cord from the power supply Replace the power supply Plug in the power cord re engage the strain relief replace the CMA support tray if necessary a