Home

Dell OpenManage Server Administrator Version 7.0 SNMP Reference Guide

image

Contents

1. TrapID Description Severity 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Information 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Information 789249 Memory Redundancy has been Lost Critical 789248 Memory redundancy has returned to Normal Information 1076994 System Event Log SEL Cleared Information 1076996 System Event Log SEL Full Logging Disabled Critical 2322176 ASR Automatic System Recovery Timer Expired Critical 2322177 ASR Automatic System Recovery Reset Occurred Critical 2322178 ASR Automatic System Recovery Power Down Occurred Critical 2322179 ASR Automatic System Recovery Power CycleOccurred Critical Traps 729 730 Traps Storage Management Alert Reference Storage M anagement s alert or event management features let you monitor the health of storage resources such as controllers connectors array disks and virtual disks Alert Monitoring and Logging The Storage M anagement Service performs alert monitoring and logging By default the Storage M anagement Service starts when the managed system starts up If you stop the Disk M anagement Service then alert monitoring and logging stops Alert monitoring does the following Updates the status of the storage object that generated the alert e Propagates the storage object s status to all the related higher
2. TrapID Description Severity 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low Predictive Failure Warning 2715520 Battery Low Predictive Failure Cleared Information 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Information 487169 CPU Thermal Trip Over Temperature Shutdown Critical 487297 CPU Thermal Trip Over Temperature Shutdown Cleared Information 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence Processor Presence detected Information 487303 CPU Not Present Processor Not Present Critical 487170 CPU BIST Built In Self Test Failure Critical 487298 CPU BIST Built In Self Test Failure Cleared Information 487176 CPU Disabled Processor D isabled Critical 487304 CPU Enabled Processor Enabled Information 487178 CPU Throttle Processor Speed Reduced Warning 487306 CPU Throttle Cleared Normal Processor Speed Information 527106 Power Supply Redundancy D egraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 728 Traps Table 27 20 BMC Traps continued
3. 702 Chassis Alerts 00004 704 LegacyAlerting 4 706 DS cd Me tite oe ote oot aS 709 Trap Variables 710 Contents 11 12 Understanding the Trap Description 711 Understanding Trap Severity 716 Instrumentation Traps 716 Miscellaneous Traps 717 Temperature Probe Traps 719 Cooling Device Traps 721 Voltage Probe Traps 723 Amperage ProbeTraps 725 Chassis Intrusion Traps 727 Redundancy UnitTraps 728 PowerSupplyTraps 730 Memory Device Traps 731 Fan Enclosure Traps 732 AC PowerCordTraps 734 Hardware Log Traps 735 Processor Device Status Traps 736 Pluggable Device Traps 738 Battery raps aa bead ES eee 739 SD Card Device Traps 741 RAC Traps 23 6s eee Seta eee Rees 742 BMCTraps 2 00005 741 28 Storage Management Alert Reference 753 Alert Monitoring andLogging 753 Viewing Alerts 024 754 Alert Severity Levels 754 SNMP Support for Storage Management Alerts 755 SNMP Trap Forwarding 755 SNMP Trap Definitions 756 SNMP Trap Variables 756 Contents Viewing SNMPTrap
4. 379 Memory Group Variable Values 382 17 BIOS Setup Control Group 389 BIOS Setup Control Group Tables 389 BIOS Setup Control Table 389 SCSI Control Table 400 Parallel Port Control Table 402 Serial Port Control Table 404 USB Control Table 406 IDE Control Table onau aaa 408 Diskette Control Table 410 Network Interface Control Table nan 412 BIOS Setting Table 415 BIOS Group Variable Values 418 18 Local Response Agent Group 429 LRA Group Tables 429 LRA Global Settings 429 LRA Global Settings Table 430 LRA Action Table o a naaa aaa 432 Local Response Agent Variable Values 434 19 Cost of Ownership Group 437 Cost of Ownership Group Tables 437 Cost of Ownership Table 437 COO Service ContractTable 448 COO Cost Event Log Table 450 COO Warranty Table 452 COO Lease Information Table 454 Contents COO Schedule Number Table 457 COO Options Table 458 COO MaintenanceTable 460 COORepairTable 0004 462 COO Support Information Table 464 COO Trouble Ticket Table 466 Cost of Ownership Variable Values
5. 468 20 Remote Access Group 471 DRAC4andDRAC5 471 Remote Access Table 471 DRAGW 3 300 op hed BRED SS a 477 Remote Access Table 478 Remote User Administration Table 487 Remote SNMP Trap Table 495 Remote Dial Up Table 500 Remote User Dial In Configuration Table 504 Remote Dial OutTable 507 Remote Access Variable Values 510 21 Cluster Grouse ye bp takuet boot Ged ae 4 527 Cluster Group 0 4 527 Cl ster Table sore oti a tena A od 527 Cluster Group Variable Values 530 22 Baseboard Management Controller Group 531 Baseboard Management Controller Group Tables 531 Baseboard Management Controller Table 531 Baseboard Management Controller Serial Interface Table 535 Contents 9 10 Baseboard Management Controller LAN Interface Table 539 Baseboard Management Controller Group Variable Values 543 23 Field Replaceable Unit Group 547 Field Replaceable Unit Group Tables 547 Field Replaceable UnitTable 547 Field Replaceable Unit Group Variable Values 551 24 Storage Management Group 553 Storage Management Group 553 Storage Management InformationGroup 555 Global DataGroup 556 Physical DevicesGroup 562 ControllerTable 563 Channe
6. Possible Data Values Meaning of Data Value defaultConfigReset 32 The remote access hardware resets to its default settings shutdown 64 The remote access hardware shuts down Table 20 4 Remote Access Monitor Capabilities Variable Name De 1 1RemoteAccessMonitorCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no monitor capabilities unknownCapabilities 1 The remote access hardware monitor capabilities are unknown extPwrSupplyMonitorIfConn The remote access hardware can be set to ectedCapable 2 monitor the external power supply if connected extPwrSupplyMonitorAlways The remote access hardware can be set to EnabledCapable 4 always monitor the external power supply 512 Remote Access Group Table 20 5 Remote Access Monitor Settings Variable Name De 1 1RemoteAccessMonitorSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 T he remote access hardware has no monitor settings unknown 1 T he remote access hardware monitor settings are unknown extPwrSupplyMonitorIfConn The remote access hardware monitors the ectedEnabled 2 external power supply if connected extPwrSupplyMonitorAlways Theremote access hardware always monitors EnabledEnabled 4 the external power supply Table 20 6 Remote Access Local Area Network LAN Capa
7. Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther 1 The cooling devicetype is not one of the following coolingDeviceTypelIsUnknown 2 The cooling device type is unknown not known or not monitored coolingDeviceTypelIsAFan 3 The cooling device type is a fan coolingDeviceTypelIsABlower 4 The cooling device type isa centrifugal blower coolingDeviceTypelsAChipFan 5 The cooling device type is a fan on an integrated circuit coolingDeviceTypeIsACabinetFan 6 The cooling device type is a cabinet fan coolingDeviceTypeIsAPowerSupplyFan 7 Thecooling device type isa power supply fan coolingDeviceTypelIsAHeatPipe 8 The cooling device type isa heat pipe coolingDeviceTypelIsRefrigeration 9 The cooling device type is an integrated refrigeration unit coolingDeviceTypeIsActiveCooling 10 Thecooling device type is an active cooling device coolingDeviceTypeIsPassiveCooling 11 Thecooling device type isa passive cooling device ThermalGroup 213 Table 10 2 Cooling Device Subtype Variable Name De 1 1CoolingDeviceSubType Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypelIsOther 1 The cooling device subtype is not one of the following coolingDeviceSubTypelIsUnknown 2 The cooling device subtype is unknown not known or not monitored coolingDeviceSubTypeIsAFanThatReads The cooling device subtype isa
8. InRPM 3 fan that reads in RPMs coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a OFF 4 fan that reads 0 off or 1 on coolingDeviceSubTypeIsAPowerSupply Thecooling device subtype isa FanThatReadsinRPM 5 power supply fan that reads in RPMs coolingDeviceSubTypeIsAPowerSupply Thecooling device subtype isa FanThatReads ONorOFF 6 power supply fan that reads 0 off or 1 on coolingDeviceSubTypeIsDiscrete 16 The cooling device subtype isa cooling device with discrete reading Table 10 3 Cooling Device Discrete Reading Variable Name De 1 1CoolingDeviceDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceIsGood 1 The cooling device discrete reading is good coolingDeviceIsBad 2 The cooling device discrete reading is bad 214 Thermal Group Table 10 4 Temperature Probe Type Variable Name De 11 TemperatureProbeTyp Data Type Integer Possible Data Values Meaning of Data Value temperatureProbeTypelsOther 1 T he temperature probe subtype is not one of the following temperatureProbeTypelsUnknown 2 T he temperature probe subtype is unknown not known or not monitored temperatureProbeTypelIsAmbientESM 3 Thetemperature probe is for ambient Embedded Systems Management ESM temperatureProbeTypeIsDiscrete 16 Thetemperature probe subtype is a temperature probe
9. DellProcessorD eviceType See Table 14 4 Read only Processor Device Manufacturer Name Name Object ID Description Syntax Access processorDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 30 1 8 Defines the name of manufacturer of the processor device DellString Read only Processor Device Status State Name Object ID Description Syntax Access processorDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 30 1 9 Defines the status state of the processor device DellProcessorD eviceStatusState See Table 14 2 Read only Processor Device Family Name Object ID Description Syntax Access processorDeviceFamily 1 3 6 1 4 1 674 10892 1 1100 30 1 10 Defines the family of the processor device DellProcessorD eviceF amily See Table Read only DeviceGroup 269 Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 11 Description Defines the maximum speed of the processor device in megahertz MHz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Processor Device Current Speed Name processorDeviceCurrent Speed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 12 Description Defines the current speed of the processor device in MHz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Processor Device External Clock Speed Name processorDeviceExte
10. Table 22 4 BMC Serial Bit Rate Type Variable Name De 1 1 BMCSerialBitRateType Data Type Integer Possible Data Values Meaning of Data Value bps9600 6 Bit rate is 9600 bps bits per second bps19200 7 Bit rate is 19200 bps bps38400 8 Bit rate is 38400 bps bps57600 9 Bit rate is 57600 bps bps115200 10 Bit rate is 115200 bps Table 22 5 BMC LAN IP Address Source Type Variable Name De 1 1BMCLANIPAddressSourceType Data Type Integer Possible Data Values Meaning of Data Value unspecified 0 Source is unspecified static l1 IP address is static dhcp 2 Dynamic Host Configuration Protocol DHCP used to obtain IP address biosOrSystemSoftware 3 BIOS or system software provided IP Address other 4 Other protocol used to obtain IP address 544 Baseboard M anagement Controller Group Table 22 6 BMC Management Controller Type Variable Name De 1 1ManagementControllerType Data Type Integer Possible Data Values Meaning of Data Value legacyBMC 0 Controller type is legacy Baseboard Management C ontroller iDRAC 8 Controller type is iDRAC iDRAC6 10 Controller type is Integrated Dell Remote Access Controller 6 iDRAC6Modular 11 Controller type is Integrated D ell Remote Access C ontroller 6 Modular iDRAC6BMC 13 Controller type is Integrated D ell R
11. deviceFamilyIsAMDTurionIIUltra DualMobileM 56 The processor family is AMD Turion II Ultra Dual C ore M obile M Processor Family deviceFamilyIsAMDTurionIIDualM obileM 57 The processor family is AMD Turion II Dual Core M obile M Processor Family deviceFamilyIsAMDAthlonIIDualM obileM 58 The processor family is AM D Athlon II Dual C ore M obile M Processor Family deviceFamilyIsAMDOpteron6100 59 The processor family is AMD Opteron 6100 Series Processor deviceFamilyIsAMDOpteron4100 60 The processor family is AMD Opteron 4100 Series Processor deviceFamilyIsAMDOpteron6200 61 The processor family is AMD Opteron 6200 Series Processor deviceFamilyIsAMDOpteron4200 62 The processor family is AMD Opteron 4200 Series Processor deviceFamilyIsMIPS 64 The processor family is MIPS deviceFamilyIsMIPSR4000 65 The processor family is M IPS R4000 deviceFamilyIsMIPSR4200 66 The processor family is M IPS R4200 deviceFamilyIsMIPSR4400 67 The processor family is M IPS R4400 deviceFamilyIsMIPSR4600 68 The processor family is MIPS R4600 H deviceFamilyIsMIPSR10000 69 The processor family is M IPS R10000 deviceFamilyIsSPARC 80 The processor family is SPARC deviceFamilyIsSuperSPARC 81 The processor family is SuperSPARC deviceFamilyIsmicroSPARCII 82 The processor family is microS
12. lt State gt example Discrete current state Good Discrete temperatur Specifies the state of the temperature sensor state lt State gt for example Discrete temperature state Good Discrete voltage state lt State gt Specifies the state of the voltage sensor for example Discrete voltage state Good Traps 693 694 Table 27 1 Trap Description Reference continued Description Line Item Explanation Fan sensor value Specifies the fan speed in revolutions per lt Reading gt minute RPM s or On Off for example Fan sensor value in RPM 2600 Fan sensor value Off Log type lt Log type gt Specifies the type of hardware log for example Log typ Embedded Server Management ESM Memory device bank location lt Bank name in chassis gt Specifies the name of the memory bank in the system that generated the message for example Memory device bank location Bank_1 Memory device location lt Device name in chassis gt Specifies the location of the memory module in the chassis for example Memory device location DIMM A Number of devices required for full Specifies the number of power supply or cooling devices required to achieve full redundancy lt Number gt redundancy for example Number of devices required for full redundancy 4 Peak value in Watts Specifies the peak value in Watts for example lt Reading gt Pe
13. temperatureProbeRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 11 1 12 Severity of the temperature probe state T his is the combined status of the temperature probe and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Temperature Probe Component Status Name Object ID Description Syntax Access temperatureProbeComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 11 1 13 The status of the temperature probe itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 637 Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 14 Description D urable unique ID for this temperature probe Syntax DisplayString Access Read only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Temperature Probe C onnection Table Name temperatureConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 Description Defines the temperature probe connection table Syntax SEQUENCE OF TemperatureC onnectionE ntry Access
14. Access powerSupplyLocationName 1 3 6 1 4 1 674 10892 1 600 12 1 8 Defines the location name of the power supply DellString Read only Power Supply Input Voltage Name Object ID Description Syntax Access 156 powerSupplyInputVoltage 1 3 6 1 4 1 674 10892 1 600 12 1 9 Defines the input voltage to the power supply in volts DellSigned32BitRange Read only Power Group Power Supply Power Unit Index Reference Name Object ID Description Syntax Access powerSupplypowerUnitIndexReference 1 3 6 1 4 1 674 10892 1 600 12 1 10 Defines the index to the associated system power unit in this chassis DellO bjectR ange Read only Power Supply Sensor State Name Object ID Description Syntax Access powerSupplySensorState 1 3 6 1 4 1 674 10892 1 600 12 1 11 Defines the state reported by the power supply sensor and supplements the state and settings of the power supply D ellPowerSupplySensorState See Table 9 4 Read only Power Supply Configuration Error Type Name Object ID Description Syntax Access powerSupplyConfigurationErrorType 1 3 6 1 4 1 674 10892 1 600 12 1 12 Defines the type of configuration error reported by the power supply sensor D ellPowerSupplyC onfigurationE rrorType See Table 9 5 Read only Power Supply Power Monitor Capable Name Object ID Description Syntax Access powerSupplyPowerMonitorCapable 1 3 6 1 4 1 674 10892 1 600 12 1 13 Defines a b
15. Description This entry is obsolete This setting is not supported by fans managed under Storage M anagement Syntax DisplayString Access Read only 622 Storage Management Group Fan Roll Up Status Name Object ID Description Syntax Access fanRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 7 1 14 Severity of the fan state T his is the combined status of the fan and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Fan Component Status Name Object ID Description Syntax Access fanComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 7 1 15 The status of the fan itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 623 624 Fan Nexus ID Name Object ID Description Syntax Access Fan Revision Name Object ID Description Syntax Access fanNexusID 1 3 6 1 4 1 674 10893 1 20 130 7 1 16 Durable unique ID for this fan DisplayString Read only fanRevision 1 3 6 1 4 1 674 10893 1 20 130 7 1 17 Indicates the revision number of the fan in the enclosure DisplayString Read only Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds t
16. Index remoteDialUpTableEntry 1 3 6 1 4 1 674 10892 1 1700 40 1 Defines the Remote Access Dial Up Table entry RemoteD ialU pTableE ntry Not accessible remoteD ialU pC hassisl ndex remoteD ialU pAdapter ndex remoteD ialU pl ndex Remote Dial Up Chassis Index Name Object ID Description Syntax Access remoteDialUpChassisIndex 1 3 6 1 4 1 674 10892 1 1700 40 1 1 Defines the index one based of the chassis containing the remote access hardware DellO bjectRange Read only 500 Remote Access Group Remote Dial Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial up functionality Syntax DellO bjectRange Access Read only Remote Dial Up Index Name remoteDialUpIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 3 Description Defines the index one based of this remote access dial up functionality Syntax DellO bjectRange Access Read only Remote Dial Up State Capabilities Name remoteDialUpStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 4 Description Defines the state capabilities of this remote access dial up functionality Syntax DellRemoteDialU pStateC apabilities See Table 20 22 Access Read only Remote Dial Up State Settings Name remoteDialUpStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 5 Description Def
17. Name objectNameEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 4 Description Name of the object as represented in Storage M anagement causing the alert Syntax DisplayString Access Read only Object OID Event Name objectOIDEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 5 Description MIB OID of the object causing the alert Syntax DisplayString Access Read only Object Nexus Event Name objectNexusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 6 Description Durable unique ID of the object causing the alert Syntax DisplayString Access Read only 670 Storage Management Group Current Status Event Name current StatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 7 Description Current status of object causing the alert if applicable Syntax DellStatus Access Read only Previous Status Event Name previousStatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 8 Description Previous status of object causing the alert if applicable Syntax DellStatus Access Read only Storage Management Group 671 672 Storage Management Group Change Management Group The Change M anagement Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis T his information is collected during an inventory scan Inventory Group The following objects describe the fields for inventory information Inventory Locale Name inventoryLocale Obje
18. Remote Access Out of Band SNMP Settings Name Object ID Description Syntax Access remoteAccessOutOfBandSNMPSettings 1 3 6 1 4 1 674 10892 1 1700 10 1 19 Defines the out of band SN MP settings of the remote access hardware D ellRemoteAccessO utO fBandSN M PSettings See Table 20 11 Read write Remote Access Simple Mail Transfer Protocol SMTP Server Internet Protocol IP Address Name Object ID Description Syntax Access remoteAccessSMTPServerIPAddress 1 3 6 1 4 1 674 10892 1 1700 10 1 20 Defines the IP address for the SMTP server used by the remote access hardware pAddress Read write Remote Access Floppy Trivial File Transfer Protocol TFTP IP Address Name Object ID Description Syntax Access remoteAccessFloppyTFTPIPAddress 1 3 6 1 4 1 674 10892 1 1700 10 1 21 Defines the IP address of the TFTP server providing the operating system image used by the remote access hardware pAddress Read write Remote Access Floppy TFTP Path Name Name Object ID Description Syntax Access remoteAccessFloppyTFTPPathName 1 3 6 1 4 1 674 10892 1 1700 10 1 22 Defines the file name of the operating system image obtained from the TFTP server used by the remote access hardware DisplayString SIZE 0 255 Read write Remote Access Group 483 Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 23 Descri
19. lt Date and time gt 698 Traps Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis The temperature probe traps use additional variables sensor location chassis location previous state and temperature sensor value reported in degrees Celsius Table 27 3 Temperature Probe Traps TrapID Description Severity Cause Temperature Probe Normal 1052 Temperature sensor returned to a Information A temperature sensor normal value on the backplane Sensor location lt Location in chassis gt board system board i or drive carrier in the Chassis location lt N ame of chassis gt specified system Previous state was lt State gt returned to a valid If sensor type is not discrete E E a Temperature sensor value in degrees Then location Celsius lt Reading gt chassis location If sensor type is discrete Discrete previous state and tem perature state lt State gt temperature sensor value are provided Temperature Probe Warning 1053 Temperature sensor detected a Warning A temperature sensor warning value Sensor location lt Location in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete D iscrete temperature state lt
20. 98 Chassis Information Group Firmware State Capabilities Name Object ID Description Syntax Access firmwareStateCapabilities 1 3 6 1 4 1 674 10892 1 300 60 1 3 Defines the capabilities of the firmware states DellStateC apabilities Read only Firmware State Capabilities Name Object ID Description Syntax Access firmwareStateCapabilities 1 3 6 1 4 1 674 10892 1 300 60 1 4 Defines the state of the firmware and allows for the setting of the firmware DellStateSettings Read write Firmware Status Name Object ID Description Syntax Access firmwareStatus 1 3 6 1 4 1 674 10892 1 300 60 1 5 Defines the status of the firmware DellStateSettings Read only Firmware Size Name Object ID Description Syntax Access firmwareSize 1 3 6 1 4 1 674 10892 1 300 60 1 6 Defines the image size of the firmware in KB A zero 0 indicates that the size is unknown DellU nsigned16BitRange Read only Chassis Information Group 99 Firmware Type Name firmwareType Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 7 Description Defines the type of the firmware Syntax D ellFirmwareType Access Read only Firmware Type Name Name firmwareTypeName Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 8 Description Defines the name of firmware type Syntax DellString Access Read only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 9 Description De
21. Access Read only BIOS Setting FODD Name biosSettingFQDD Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 12 Description Fully Qualified D evice D escriptor FQDD for the BIOS setting Syntax DisplayString Access Read only BIOS Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 17 1 Speaker Control Capabilities Unique Variable Name De11SpeakerControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Speaker control capabilities are unknown enableCapable 2 Setup BIOS can enable speaker control lowCapable 4 Setup BIOS can set the speaker volume to low mediumCapable 8 Setup BIOS can set the speaker volume to medium 418 BIOS Setup Control Group Table 17 1 Speaker Control Capabilities Unique continued Variable Name De11SpeakerControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value highCapable 16 Setup BIOS can set the speaker volume to high allVolumeCapable 30 Setup BIOS can set the speaker volume to any of the three settings Table 17 2 Speaker Control Settings Unique Variable Name De11SpeakerControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Speaker control state is unknown enabled 2 Speaker control is enabled low 4 Speaker
22. Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 6 Description Identifies the name of the controller as represented in Storage M anagement to which this array disk is connected Syntax DisplayString Access Read only Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Table This table describes the connections between array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found K NOTE Only array disks that are NOT part of an enclosure are listed in this table Backplanes are considered enclosures by Storage Management Storage Management Group 615 The following object sets up the Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 Description Defines the array disk channel connection table Syntax SEQUENCE OF ArrayDiskC hannelC onnectionEntry Access Not accessible Array Disk Channel Connection Entry
23. Chassis Allow Set Commands From SNMP Name Object ID Description Syntax Access chassisallowSETCommands fromSNMP 1 3 6 1 4 1 674 10892 1 300 10 1 37 Specifies whether Simple Network M anagement Protocol SNM P Set type commands are allowed by Server Administrator This attribute does not reflect whether SNM P Set type commands are allowed by the SNMP master agent D ellBoolean Read only Chassis Power Button Control Capabilities Unique Name Object ID Description Syntax Access chassisPowerButtonControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 38 Defines the capabilities of the power button control function D ellPowerButtonC ontrolC apabilities See Table 6 16 Read only Chassis Power Button Control Settings Unique Name Object ID Description chassisPowerButtonControlSettingsUnique 1 3 6 1 4 1 674 10892 1 300 10 1 39 Defines the current reading and allows setting of the power button control hardware 81 Chassis Information Group Name chassisPowerButtonControlSettingsUnique Syntax D ellPowerButtonC ontrolSettings See Table 6 17 Access Read write Chassis Reseller Name Name chassisResellerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 40 Description Defines the name of the chassis reseller Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1
24. Defines the custom fan power and performance management setting for the C ustom power profile DellFanPowerPerformanceM anagementType Read only Power Group Variable Values This section includes definitions for server administrator specific variable values used in this section 185 Power Group Table 9 1 Power Supply State Capabilities Unique Variable Name De 1 1PowerSupplyStateCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onlineCapable 2 The power supply can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The power supply s capabilities are not ready Table 9 2 Power Supply State Settings Unique Variable Name De 1 1PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onLine 2 The power supply s state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The power supply s state is not ready fanFailure 8 The power supply fan has failed onlineAndFanFailure 10 The power supply is online and indicating that its fan is not working powerSupplyIsON 16 The power supply is indicating that it is on powerSupplyIsoOk 32 The power supply is indicating that it is OK
25. DellO bjectRange Read only 262 Device Group Pointing Device State Capabilities Name Object ID Description Syntax Access pointingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 10 1 3 Defines the capabilities of the pointing device DellStateC apabilities Read only Pointing Device State Settings Name Object ID Description Syntax Access pointingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 10 1 4 Defines the state of the pointing device DellStateSettings Read write Pointing Device Status Name Object ID Description Syntax Access pointingDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 10 1 5 Defines the status of the pointing device DellStatus Read only Pointing Port Index Reference Name Object ID Description Syntax Access pointingPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 10 1 6 Defines the index to the pointing port in this chassis DellO bjectRange Read only DeviceGroup 263 Pointing Device Type Name pointingDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 10 1 7 Description Defines the type of the pointing device Syntax DellPointingD eviceType See Table 14 1 Access Read only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1 3 6 1 4 1 674 10892 1 1100 10 1 8 Description Defines the number of buttons on the pointing device Syntax DellU nsigned8BitRange Access Read only Keyboard Device Table Name keyboardDe
26. DellO bjectRange Read only Network Device Index Name Object ID Description Syntax Access networkDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 90 1 2 Defines the index one based of the network device DellO bjectRange Read only Network Device Status Name Object ID Description Syntax Access networkDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 90 1 3 Defines the status of the network device DellStatus Read only Network Device Connection Status Name Object ID Description Syntax Access networkDeviceConnectionStatus 1 3 6 1 4 1 674 10892 1 1100 90 1 4 Defines the connection status of the network device D ellN etworkD eviceC onnectionStatus see Table 14 20 Read only 304 Device Group Network Device Description Name Name networkDeviceDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 5 Description Defines the description of the network device Syntax DellString Access Read only Network Device Product Name Name networkDeviceProductName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 6 Description Defines the product name of the network device Syntax DellString Access Read only Network Device Vendor Name Name networkDeviceVendorName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 7 Description Defines the name of the vendor of the network device Syntax DellString Access Read only Network Device Service Name Name networkDeviceServiceNam Object ID 1 3 6 1 4 1
27. Description Syntax Access DRsIdlePower 1 3 6 1 4 1 674 10892 2 4 1 1 3 Defines the power in Watts required by the chassisinfrastructure plus the sum of the minimum power requirements for all systems currently turned on DellPowerReading Read only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 4 Description Defines the power limit in Watts at which server throttling takes place Syntax DellPowerReading Access Read only DRsPowerSurplus Name DRsPowerSurplus Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 5 Description Defines the power surplus in Watts remaining above the drsPotentialPower reading Syntax DellPowerReading Access Read only Dell Remote Access Controller Out of BandGroup 707 DRsKWhCumulative Name DRskKWhCumulative Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 6 Description Defines the cumulative chassis power usage in KW h since last reset Syntax D ellPowerReading Access Read only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 7 Description Defines the timestamp of the most recent chassis power accumulator reset Syntax DellTimestamp Access Read only DRsWattsPeakUsage Name DRsWattsPeakUsage Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 8 Description Defines the chassis peak power usage in Watts since last reset Syntax D ellPowerReading Access Read only DRsWattsPeakTime Name DRsWattsPeakTime
28. Description systemBIOSCharacteristics Defines characteristics of the system BIOS T his attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit 63 is the first bit in the value and bit 0 is the last bit in the value See the description of D ellUnsigned64BitRange at the beginning of this file for more information on the format of the value Bits 48 63 need to be examined in the context of the system ID The system ID is available in the attribute chassisID If the value for chassisID is non zero bits 48 63 have the meaning defined below Bit Position Meaning if Set Bit OReserved Bit 1Reserved Bit 2Unknown Bit 3BIOS Characteristics Not Supported Bit 4ISA is supported Bit 5M CA is supported Bit 6EISA is supported Bit 7PCI is supported Bit 8PC Card PCM CIA is supported Bit 9Plug and Play is supported Bit LOAPM is supported Bit 11BIOS is U pgradeable F lash Bit 12BIOS shadowing is allowed Bit 13VL VESA is supported Bit 14ESCD support is available Bit 15Boot from CD is supported Chassis InformationGroup 95 Name systemBIOSCharacteristics Description Bit Position Meaning if Set Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card PCM CIA is supported Bit 19EDD Enhanced Disk Drive Specification is supported Bit 20Int 13h Japanese F loppy for NEC 9800 1 2mb 3 5 in 1k Bytes Sector 360 RPM is supported Bit 21Int 13h Japanese
29. Name Object ID Description Syntax Access systemResourcelInterruptStateCapabilities 1 3 6 1 4 1 674 10892 1 500 50 1 3 Defines the capabilities of this system resource interrupt D ellStateC apabilities Read only System Resource Interrupt State Settings Name Object ID Description Syntax Access systemResourceInterruptStateSettings 1 3 6 1 4 1 674 10892 1 500 50 1 4 Defines the state of this system resource interrupt DellStateSettings Read write System Resource Interrupt Status Name Object ID Description Syntax Access systemResourceInterruptStatus 1 3 6 1 4 1 674 10892 1 500 50 1 5 Defines the status of this system resource interrupt DellStatus Read only System Resource Group 141 System Resource Interrupt Owner Index Reference Name systemResourcelInterruptOwnerIndexReferenc Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 6 Description Defines the index for the associated system resource owner in this chassis Syntax DellO bjectRange Access Read only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 7 Description Defines the share disposition of the system resource interrupt Syntax D ellResourceShareD isposition See Table 8 3 Access Read only System Resource Interrupt Level Name systemResourcelInterruptLevel Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 8 Description Defines
30. Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 9 Description Defines the timestamp of the most recent chassis peak power usage Syntax DellTimestamp Access Read only 708 Dell Remote Access Controller Out of Band Group DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 10 Description Defines the chassis minimum power usage in W atts since last reset Syntax DellPowerReading Access Read only DRsWattsMinTime Name DRsWattsMinTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 11 Description Defines the timestamp of the most recent chassis minimum power usage Syntax DellPowerReading Access Read only DRsWattsResetTime Name DRsWattsResetTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 12 Description Defines the timestamp of the most recent reset of the chassis minimum maximum W atts readings Syntax DellTimestamp Access Read only Dell Remote Access Controller Out of BandGroup 709 DRsWattsReading Name DRsWattsReading Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 13 Description Defines the instantaneous chassis power usage in Watts Syntax D ellPowerReading Access Read only DRsAmpsReading Name DRsAmpsReading Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 14 Description Defines the instantaneous chassis current usage in Watts Syntax D ellPowerReading Access Read only CMC PSU Information The following M IB tables provide information on the chassis power supply unit DRsPSUChassisIndex Name DRsPS
31. Physical Memory Array State Settings Name Object ID Description Syntax Access physicalMemoryArrayStateSettings 1 3 6 1 4 1 674 10892 1 1300 10 1 4 Defines the state of the physical memory array DellStateSettings read write Physical Memory Array Status Name Object ID Description Syntax Access physicalMemoryArrayStatus 1 3 6 1 4 1 674 10892 1 1300 10 1 5 Defines the status of the physical memory array DellStatus Read only Physical Memory Array Use Name Object ID Description Syntax Access physicalMemoryArrayUse 1 3 6 1 4 1 674 10892 1 1300 10 1 6 Defines the use of the physical memory array DellPhysicalM emoryArrayU se See Table 16 2 Read only MemoryGroup 365 Physical Memory Array Error Checking and Correcting ECC Type Name physicalMemoryArrayECCType Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 7 Description Defines the ECC type used by the physical memory array Syntax DellPhysicalM emoryArrayE C C Type See Table 16 2 Access Read only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 8 Description Defines the location of the physical memory array Syntax DellPhysicalM emoryArrayL ocation See Table 16 1 Access Read only Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 9 Description Defines the size in KB of the physical memory array Syntax De
32. Syntax D ellG enericPortC onnectorType Access Read only 254 Port Group Port Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 13 1 Pointing Port Connector Type Variable Name De11PointingPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelIsOther 1 The pointing port connector type is not one of the following connectorPortTypelIsUnknown 2 The pointing port connector type is unknown connectorPortTypelsSerial 3 The pointing port connector type is serial connectorPortTypeIsPS2 4 The pointing port connector typeisa Personal System 2 PS 2 connectorPortTypelIsInfrared 5 The pointing port connector type is infrared connectorPortTypelIsHPHIL 6 The pointing port connector type is HP HIL connectorPortTypeIsBusMouse 7 The pointing port connector type isa bus mouse connectorPortTypeIsADB 8 The pointing port connector type is ADB connectorPortTypeIsDB9 9 The pointing port connector type is nine pin DB 9 connectorPortTypeIsMicroDIN 10 The pointing port connector type is micro Deutsche Industrie Norm DIN connectorPortTypelIsAccessBusUSB The pointing port connector type is 11 Access Bus USB connectorPortTypelIsPC98 12 The port connector type is a PC 98 PortGroup 255 Table 13 2 Keyboard
33. The bytes have the same definition type as D ellStatusR edundancy Syntax Octet String Size 1 128 Access Read only 64 System State Group System State Event Log Status Name Object ID Description Syntax Access systemStateEventLogStatus 1 3 6 1 4 1 674 10892 1 200 10 1 41 Defines the overall status of this chassis ESM event log DellStatus Read only System State Power Unit Status Combined Name Object ID Description Syntax Access systemStatePowerUnitStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 42 Defines the combined status of all power units of this chassis DellStatus Read only System State Power Unit Status List Name Object ID Description Syntax Access systemStatePowerUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 43 Lists the status of each power unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit The first byte returned represents the status of the first power unit and so on The bytes have the same definition type as D ellStatus Octet String Size 1 128 Read only 65 System State Group System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 44 Description Defines the combined status of all cooling units of this chassis Syntax DellStatus Access Read only System State Cooling Unit Status L
34. Variable Name De 1 1RemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value logResetCapable 2 The remote access hardware can reset its integrated logs hardResetCapable 4 The remote access hardware can perform a hard reset softResetCapable 8 The remote access hardware can perform a soft reset gracefulResetCapable 16 The remote access hardware can gracefully shut down and perform a soft reset defaultConfigResetCapable 32 The remote access hardware can reset to its default settings shutdownCapable 64 The remote access hardware can shut down Table 20 3 Remote Access Control Settings Variable Name De 1 1RemoteAccessControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no control settings unknown 1 The remote access hardware control settings are unknown logReset 2 The remote access hardware resets its integrated logs hardReset 4 The remote access hardware performs a hard reset softReset 8 The remote access hardware performs a soft reset gracefulReset 16 The remote access hardware shuts down and perform a soft reset Remote Access Group 511 Table 20 3 Remote Access Control Settings continued Variable Name De 1 1RemoteAccessControlSettings Data Type Integer
35. processorDeviceStatusStateSettings 1 3 6 1 4 1 674 10892 1 1100 32 1 4 Defines the state settings of the processor device status probe DellStateSettings Read write Processor Device Status Status Name Object ID Description Syntax Access processorDeviceStatusStatus 1 3 6 1 4 1 674 10892 1 1100 32 1 5 Defines the status of the processor device status probe This status is joined into the processorD eviceStatus attribute DellStatus Read only 276 Device Group Processor Device Status Reading Name Object ID Description Syntax Access processorDeviceStatusReading 1 3 6 1 4 1 674 10892 1 1100 32 1 6 Defines the reading of the processor device status probe DellProcessorD eviceStatusReading Read only Processor Device Status Location Name Name Object ID Description Syntax Access processorDeviceStatusLocationName 1 3 6 1 4 1 674 10892 1 1100 32 1 7 Defines the location name of the processor device status probe DellString Read only Processor Device Status Port Index Reference Name Object ID Description Syntax Access processorDeviceStatusPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 32 1 8 Defines the index one based of the associated processor port in the same chassis DellO bjectRange Read only Cache Device Table Name Object ID Description Syntax Access cacheDeviceTable 1 3 6 1 4 1 674 10892 1 1100 40 Defines the Cache D evice Table SEQUENCE OF CacheD
36. the address field of your browser https localhost lt 1311 or user specified port number gt To manage a system remotely using Server Administrator type one of the following in the address field of your browser https lt systemname gt lt 1311 or user specified port number gt or https lt IP address gt lt 1311 or user specified port number gt Systems Management Software The following objects describe the fields for server administrator systems management information The systems management software variables are scalar objects meaning that they are not related to other management information base M IB objects and are thus not placed in a table Systems M anagement Software Group 43 Systems Management Software Name Name systemManagementSoftwareName Object ID 1 3 6 1 4 1 674 10892 1 100 1 Description Defines the systems management software product name Syntax DellString Access Read only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1 3 6 1 4 1 674 10892 1 100 2 Description Defines the version number of the systems management software Syntax DellString Access Read only Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1 3 6 1 4 1 674 10892 1 100 3 Description Defines the build number of the systems management software Syntax DellUnsigned16BitRange Access Read only Systems Management
37. typ Hypervisor SD card state lt State of SD card gt Specifies the state of the SD card for example SD card state Present Failed Sensor location lt Location in chassis gt Specifies the location of the sensor in the specified chassis for example Sensor location CPU1 Temperature sensor value in degrees Celsius lt Reading gt Specifies the temperature in degrees C elsius for example Temperature sensor value in degrees Celsius 30 Traps 695 Table 27 1 Trap Description Reference continued Description Line Item Explanation Voltage sensor value Specifies the voltage sensor value in volts for in Volts example lt Reading gt Voltage sensor value 1 693 Understanding Trap Severity Traps often contain information about values recorded by probes or sensors Probes and sensors monitor critical components for values such as amperage voltage and temperature W hen an event occurs on your system the Server Administrator sends information about one of the following event types to the system management console Information I nformational An event that describes the successful operation of a unit such as a power supply turning on or a sensor reading returning to normal e Waming An event that is not necessarily significant but may indicate a possible future problem such as crossing a warning threshold e Critical Error A significant event that indicate
38. writeProtect 128 Device is write protected standby 256 Deviceisin standby mode Table 14 30 SD Card Device Card Licensed Variable Name DellSDCardDeviceCardLicensed Data Type Integer Possible Data Values Meaning of Data Value unlicensed 0 SD card is not licensed by system vendor DeviceGroup 347 Variable Name DellSDCardDeviceCardLicensed Data Type Integer Possible Data Values Meaning of Data Value licensed 1 SD card is licensed by system vendor ipmiReady 2 Device isIPM ready fullReady 4 Device is full ready offline 8 Device is offline failed 16 Device is failed active 32 Device is active bootable 64 Device is bootable writeProtect 128 Device is write protected standby 256 Device isin standby mode 348 Device Group Slot Group The Slot Group provides information about the types of slots that your system supports This management information base M IB group also provides information about the voltages capabilities states and settings that are possible for these slots System Slot Group Table The System Slot Group defines objects in the System Slot M IB table System Slot Table The following object sets up the System Slot Table Name systemSlotTable Object ID 1 3 6 1 4 1 674 10892 1 1200 10 Description Defines the System Slot Table Syntax IntegerSystemStateT ableE ntry Access Not accessible System Slot Table Entry Name systemSl
39. 4 BIOS Variable Values This section explains any Server Administrator specific variables and data types that are used in this section In the BIOS group example there are 17 unique Server Administrator specific variable meanings Information on each Server Administrator specific variable is presented in a formatted table Other Documents You May Need In addition to this guide you can access the following guides available on the Dell Support website at support dell com manuals On the M anuals page click Software Systems M anagement C lick the appropriate product link on the right side to access the documents e The Server Administrator M essages R eference G uide lists the messages that you can receive on your systems management console or on your operating system s event viewer T his guide explains the text severity and cause of each message that the server administrator issues e The Server Administrator CIM Reference Guide documents the Common Information M odel CIM provider an extension of the standard management object format M OF file The Server Administrator CIM provider documents supported classes of management objects e The Glossary provides information on the terms used in this document Introduction to the Server Administrator SNMP Subagent This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNM P protocol For each
40. Access Read only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 20 Description The status of the virtual disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 664 Storage Management Group Virtual Disk Nexus ID Name Object ID Description Syntax Access virtualDiskNexusID 1 3 6 1 4 1 674 10893 1 20 140 1 1 21 Durable unique ID for this virtual disk DisplayString Read only Virtual Disk Array Disk Type Name Object ID Description Syntax Access virtualDiskArrayDiskType 1 3 6 1 4 1 674 10893 1 20 140 1 1 22 Identifies the type of array physical disks used to create the virtual disk Possible values 1 SAS 2 SATA 3 SCSI 4 IDE 99 Unknown Integer Read only Virtual Disk Bad Blocks Detected Name Object ID Description Syntax Access virtualDiskBadBlocksDetected 1 3 6 1 4 1 674 10893 1 20 140 1 1 23 Indicates if virtual disk has bad blocks Value 0 No 1 Yes 2 Not Applicable 99 Unknown Integer Read only Storage Management Group 665 Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 24 Description Indicates if virtual disk is encrypted Value 0 No 1 Yes 99 Unknown Syntax Integer Access Re
41. COO Operating System Upgrade Date Name cooOperatingSystemUpgradeDate Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 34 Description Defines the upgrade file date for this operating system Syntax DellC ostofO wnershipString Access Read write COO Depreciation Duration Name cooDepreciationDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 35 Description Defines the length of depreciation for this system Syntax DellUnsigned32BitRange Access Read write 446 Cost of Ownership Group COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 36 Description Defines the unit of time for the depreciation of this system Syntax DellCooM onthYearD urationType Access Read write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 37 Description Defines the percentage of depreciation for this system Syntax DellUnsigned32BitRange Access Read write COO Depreciation Method Name Name cooDepreciationMethodName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 38 Description Defines the name of the depreciation method for this system Syntax DellC ostofO wnershipString Access Read write COO Registration Is Registered Name cooRegistrationIsRegistered Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 39 Description Specifies whether this system is registered or not Syntax DellBoolean Access Read write Costof Ownership Group 44
42. Change M anagement Group 673 Chassis Information Group tables 71 Chassis Information Table 71 Event Log Table 88 Firmware Table 98 Intrusion Table 101 103 POST Log Table 86 System BIOS Table 91 UUID Table 84 Variable Values 108 Cluster Group 527 Cluster Table 527 variable values 530 Cost of Ownership Group COO Cost Event Log Table 450 COO Lease Information Table 454 COO Maintenance Table 460 COO Options Table 458 COO Repair Table 462 COO Schedule Number Table 457 Index 801 COO ServiceC ontract Table 448 COO Support Information Table 464 COO Trouble Ticket Table 466 COO Warranty Table 452 Cost of Ownership Table 437 Cost of Ownership tables 437 data types common 789 state capabilities 790 state settings 791 status 792 status probe 793 status redundancy 792 Dell RAC Out of Band Group 683 Chassis Alerts 704 Chassis Power 697 Chassis Status 687 CMC Power Information 698 CMC PSU Information 702 Legacy Alerting 706 Product Information 683 Device added to system 738 Device configuration error detected 738 Device Group 674 Cache Device Table 277 Generic Device Table 294 Keyboard Device Table 264 Index Memory Device M apped Address Table 291 Memory Device Table 283 PCI Device Configuration Space Table 300 PCI Device Table 297 Pointing Device Table 262 Processor Device Table 267 variable values 320 E Event Log viewing ent
43. DMA Table 143 System Resource Group Variable Values 146 9 Power Group vscs2os ch cee tiee ee wes 151 PowerGroupTables 151 PowerUnitTable 151 Power Supply Table 154 Voltage Probe Table nonna aaa aaa 158 Amperage Probe Table 163 AC Power Switch Table 169 AC Power Cord Table 171 Battery Table oona 174 Power Usage Table nananana aaa aaa 176 Power Profile Table 182 Power Group Variable Values 185 Contents 10 Thermal Group s a a anaana anana 199 Thermal Group Tables 199 Cooling Unit Table oaoa aaa 199 Cooling Device Table ononon aa aaa 202 Temperature Probe Table 207 Thermal Group Variable Values 213 11 User Security Group 217 User Security Group Table 217 User Security Table aonana 217 12 Remote Flash BIOS Group 221 Remote Flash BIOS Group Table 221 Remote Flash BIOS Table 221 Remote Flash BIOS Variable Values 224 13 Port Group Wied Pee a ated oo Se 227 Port Group Tables 227 PointingPortTable 227 Keyboard PortTable 04 4 230 Processor PortTable 233 Memory Device PortTable 236 Monitor Port Table 044 239 Small Computer System Interface SCSI
44. Data Type Integer Possible Data Values Meaning of Data Value speakerControl 1 LRA is set to issue a speaker beep consoleAlert 2 LRA is set to issue a console alert broadcastMessage 4 LRA is set to issue a broadcast message osShutDown 8 LRA is set to issue an operating system shutdown reboot 16 LRA is set to issue a system reboot powerCycle 32 LRA is set to issue a system power cycle powerOFF 64 LRA is set to issue a system power off executeApplication 256 LRA is set to start a user mode application all LRASettingsUnique 383 LRA is set to all LRA settings combinations 436 Local Response Agent Group Cost of Ownership Group The Cost of Ownership COO Group provides a full set of cost tracking objects including fields for the computer s manufacturer insurer lessor warranty user trouble tickets and many others You can use these management information base M IB objects to obtain accurate and complete measurements of the cost of each computer asset in your organization Cost of Ownership Group Tables The Cost of Ownership Group defines objects in the following M IB tables e Cost of Ownership Table on page 437 e COO Service Contract Table on page 448 e COO Cost Event Log Table on page 450 e COO Warranty Table on page 452 e COO Lease Information Table on page 454 e COO Schedule Number Table on page 457 e COO Options Table on page 458 e COO Maintena
45. Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no settings capabilities unknown 1 The power button settings are unknown enabled 2 The power button state is enabled disabled 4 The power button state is disabled Chassis Information Group 117 Table 6 18 NMI Button Control Capabilities Variable Name De 1 1NMIButtonControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no capabilities unknownCapabilities 1 TheNMI button capabilities are unknown enableCapable 2 The NMI button can be enabled online or disabled offline Table 6 19 NMI Button Control Settings Variable Name De 1 1NMIButtonControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no settings capabilities unknown 1 The NMI button settings are unknown enabled 2 TheNM I button state is enabled disabled 4 TheNM I button state is disabled Table 6 20 System Properties Variable Name De11SystemProperties NOTE These values are bit masks so combination values are possible Data Type Integer Possible Data Values Meaning of Data Value none 0 No properties energySmart 1 The system is an Energy Smart System 118 Chassis Information Group Table 6 21 Chassis System Class Variable Name De11Chassi
46. Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power switch s settings are unknown input SourceCord1NoReturn 2 Input sourceisAC power cord 1 with no return input SourceCord1Return 4 Input source is AC power cord 1 with return input SourceCord2NoReturn 8 Input sourceisAC power cord 2 with no return inputSourceCord2Return 16 Input sourceisAC power cord 2 with return input SourceShared 32 Input source is shared Power Group 193 Table 9 12 AC Power Switch Redundancy Mode Variable Name De 1 1ACPowerSwitchRedundancyMode Data Type Integer Possible Data Values Meaning of Data Value nonRedundant 1 TheAC power switch is not expecting redundancy redundant 2 The AC power switch is expecting redundancy Table 9 13 AC Power Cord State Capabilities Variable Name De 1 1ACPowerCordStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power cord s capabilities are unknown onlineCapable 2 TheAC power cord can be disabled offline or enabled online notReadyCapable 4 TheAC power cord s capabilities are not ready Table 9 14 AC Power Cord State Settings Variable Name De 1 1ACPowerCordStateSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power cord s state is unknown online 2 TheAC
47. Description Defines the Remote Flash BIOS Table Syntax RemoteF lashBIO STableE ntry Access Not accessible Remote Flash BIOS Table Entry Name remoteFlashBIOSTableEntry Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 Description Defines the Remote Flash BIOS Table entry Syntax RemoteF lashBIO STableE ntry Access Not accessible Index remoteF lashBI O SchassisI ndex remoteF lashBI O SIndex Remote Flash BIOS Group 221 Remote Flash BIOS Chassis Index Name remoteF LlashBlOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Remote Flash BIOS Index Name remoteF lashBIOSIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 2 Description Defines the index to the remote BIOS update hardware on this system Syntax DellO bjectRange Access Read only Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 3 Description Defines the capabilities of the remote BIOS update hardware on this system Syntax D ellRemoteF lashBI O SStateC apabilitiesU nique See Table 12 1 Access Read only Remote Flash BIOS State Settings Unique Name remoteFlashBlOSStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 4 Description Defines the state and settings of the remote BIOS update hardware on this system Syntax DellRemoteF lashBI O SStateSettingsU
48. INTEGER Read only Array Disk Dell Certified Name Object ID Description Syntax Access arrayDiskDellCertified 1 3 6 1 4 1 674 10893 1 20 130 4 1 36 Indicates if array disk is certified by Dell Value 1 Certified 0 Not Certified 99 Unknown Integer Read only Array Disk Alta Vendor Id Name Object ID Description Syntax Access arrayDiskAltaVendorld 1 3 6 1 4 1 674 10893 1 20 130 4 1 37 Provides vendor information for Alta interposer Octet String Read only Storage Management Group 611 Array Disk Alta Product Id Name Object ID Description Syntax Access arrayDiskAltaProductIid 1 3 6 1 4 1 674 10893 1 20 130 4 1 38 Provides product ID for Alta interposer Octet String Read only Array Disk Alta Revision Id Name Object ID Description Syntax Access arrayDiskAltaRevisionld 1 3 6 1 4 1 674 10893 1 20 130 4 1 39 Provides revision ID for Alta interposer Octet String Read only Array Disk Encryption Capable Name Object ID Description Syntax Access arrayDiskEncryptionCapable 1 3 6 1 4 1 674 10893 1 20 130 4 1 40 Indicates if physical disk is encryption capable Value 1 Capable 0 Not Capable 99 Not Applicable Integer Read only Array Disk Encrypted Name Object ID Description Syntax Access arrayDiskEncrypted 1 3 6 1 4 1 674 10893 1 20 130 4 1 41 Indicates if the physical disk has encryption enabled Value 1 Yes 0 No 99
49. Management to which this temperature probe belongs DisplayString Read only Storage Management Group 639 Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs Syntax Integer Access Read only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system The following object sets up the Enclosure M anagement M odule Table Name enclosureManagementModuleTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 Description Defines the enclosure management module table Syntax SEQUENCE OF EnclosureM anagementM oduleE ntry Access Not accessible Enclosure Management Module Entry Name EnclosureManagementModuleEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 Description Defines the enclosure management module table entry Syntax EnclosureM anagementM oduleEntry Access Not accessible Index enclosureM anagementM oduleN umber 640 Storage Management Group Enclosure Management Module Number Name Object ID Description Syntax Access enclosureManagementModuleNumber 1 3 6 1 4 1 674 10893 1 20 130 13 1 1 Identifies the instance number of the enclosure management module entry Integer Read only Enclosure Management Modu
50. Name arrayDiskChannelConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 Description Defines the array disk channel connection table entry Syntax ArrayD iskC hannelC onnectionE ntry Access Not accessible Index arrayD iskEnclosureC onnectionN umber Array Disk Channel Connection Number Name arrayDiskChannelConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 1 Description Identifies the instance number of the array disk channel connection entry Syntax Integer Access Read only Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 2 Description Identifies the name of the array disk in this connection as represented in Storage M anagement Syntax DisplayString Access Read only 616 l Storage M anagement Group Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 3 Description Identifies the instance number of the array disk in the arrayD iskTable in this connection Syntax Integer Access Read only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 4 Description Identifies the name of the channel as represented in Storage Management to which is array disk is connected Syntax DisplayString Access Read only Array Disk Channel Connection Channel Nu
51. Name cacheDeviceprocessorDeviceIndexReferenc Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 6 Description Defines the index number of the processor device with which this cache device is associated Syntax DellO bjectRange Access Read only Cache Device Type Name cacheDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 7 Description Defines the type of cache device Syntax DellC acheD eviceType See Table 14 7 Access Read only Device Group 279 Cache Device Location Name Object ID Description Syntax Access cacheDeviceLocation 1 3 6 1 4 1 674 10892 1 1100 40 1 8 Defines the location of the cache device DellC acheD eviceL ocation See Table 14 13 Read only Cache Device Status State Name Object ID Description Syntax Access cacheDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 40 1 9 Defines the status state of the cache device DellC acheD eviceStatusState See Table 14 10 Read only Cache Device External Socket Name Name Object ID Description Syntax Access cacheDeviceExternalSocketName 1 3 6 1 4 1 674 10892 1 1100 40 1 10 Defines the external socket name of the cache device if the cache is socketed DellString Read only Cache Device Level Name Object ID Description Syntax Access cacheDeviceLevel 1 3 6 1 4 1 674 10892 1 1100 40 1 11 Defines the level of the cache device DellC acheD eviceL evel See Table 14 8 Read only 280 Device Group Cache Device Maxi
52. Name keyboardDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 5 Description Defines the status of the keyboard device Syntax DellStatus Access Read only Keyboard Port Index Reference Name keyboardPort IndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 6 Description Defines the index to the associated the keyboard port in this chassis Syntax DellStatus Access Read only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 7 Description Defines the name of the keyboard type Syntax DellString Access Read only Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 8 Description Defines the name of the keyboard layout Syntax DellString Access Read only 266 Device Group Processor Device Table Name Object ID Description Syntax Access processorDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 30 Defines the Processor D evice Table SEQUENCE OF ProcessorD eviceTableE ntry Not accessible Processor Device Table Entry Name Object ID Description Syntax Access Index processorDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 30 1 Defines the Processor D evice Table entry ProcessorD eviceTableE ntry Not accessible processorD evicechassisl ndex processorD evicel ndex Processor Device Chassis Index Name Object ID Description Syntax Access processorDevicechassisIndex 1 3 6 1 4 1 6
53. Not Applicable Integer Read only 612 Storage Management Group Array Disk Power State Name arrayDiskPowerState Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 42 Description Indicates power state of a physical drive Value 0 Spun up 1 Spun down 255 Transition Syntax Integer Access Read only Array Disk Enclosure Connection Table This table describes the connections among array disks their enclosure and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found K NOTE Only array disks that are part of an enclosure are listed in this table Backplanes are considered enclosures by Storage Management The following object sets up the Array Disk Enclosure C onnection Table Name arrayDiskEnclosureConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 Description Defines the array disk enclosure connection table Syntax SEQUENCE OF ArrayD iskEnclosureC onnectionEntry Access Not accessible Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 Description Defines the array disk enclosure connection table entry Syntax ArrayD iskE nclosureC onnectionE ntry Access Not accessible Index arrayD iskE nclosureC onnectionN umber Storage Management Group 613 Array Disk Enclosure Connection Numbe
54. Not all system components may be included Syntax ObjectStatusE num Access Read only Global Storage Status Name globalStorageStatus Object ID 1 3 6 1 4 1 674 10892 5 2 3 0 Description This attribute defines the overall storage status being monitored by the remote access card Syntax ObjectStatusE num Access Read only 746 iDRAC7 MIB IDRAC7 Traps TheiDRAC 7 generates events that result in Simple Network Management Protocol SNM P traps and or entries in the iDRAC 7 Lifecycle Log This section describes the traps also known as alerts generated by the iD RAC 7 TheiDRAC 7 generates events in response to changes in the status of sensors and other monitored parameters W hen an event with predefined characteristics occurs on your system the SNM P subagent sends information about the event along with trap variables to the management console Each event generates an identifier called the trap ID and alist of trap variables that provide additional details about the event The trap variables are listed in the following Trap Variables on page 747 The traps of the iDRAC 7 MIB are organized into five subgroups of traps Each subgroup corresponds to one of the five categories of events that iDRAC7 supports the System H ealth Storage H ealth U pdates Audit and C onfiguration categories H ere is a list of the trap subgroups are e System Trap Group Storage Trap Group e Updates Trap Group e Audit Trap Group e Con
55. Read only Controller Partner Status Name Object ID Description Syntax Access controllerPartnerStatus 1 3 6 1 4 1 674 10893 1 20 130 1 1 13 This entry is obsolete for Storage Management DisplayString Read only Storage Management Group 567 Controller Host Port Count Name controllerHostPortCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 14 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 15 Description Identifies the size of memory in megabytes on the controller If this size is 0 it is less than a megabyte T his attribute is only supported on Adaptec controllers Syntax Integer Access Read only Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 16 Description Identifies the size of memory on the controller that is less than a megabyte T his combined with the controllerM emorySizel nM B is the total size of the memory T his attribute is only supported on Adaptec controllers Syntax Integer Access Read only Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 17 568 Storage Management Group Description Syntax Access controllerDriveChannelCount This entry is obsolete Fibre c
56. Setup BIOS is set to boot bya device list bootFromCDROMFirst 16 Setup BIOS is set to boot by CD first Table 17 7 BIOS Password Control Capabilities Variable Name De11BTOSPasswordControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known 1 unknown passwordControlEnableCapable Setup BIOS is capable of enabling 2 password changes BIOS Setup Control Group 421 Table 17 7 BIOS Password Control Capabilities continued Variable Name De11BTOSPasswordControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value passwordControlJumperDisable Setup BIOS is capable of Capable 4 determining if password control can be jumper disabled passwordControlEnableANDJumper Setup BIOS is capable of enabling DisableCapable 6 password changes and of determining if password control can be jumper disabled Table 17 8 BIOS Password Control Settings Unique Variable Name De 1 1BITOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1 Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by ajumper Table 17 9 BIOS Password Control
57. Syntax Access genericDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 1 Defines the index one based of this chassis DellO bjectRange Read only Generic Device Index Name Object ID Description Syntax Access genericDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 2 Defines the index of the generic device in this chassis DellO bjectRange Read only Generic Device State Capabilities Name Object ID Description Syntax Access genericDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 70 1 3 Defines the capabilities of the generic device DellStateC apabilities Read only DeviceGroup 295 Generic Device State Settings Name Object ID Description Syntax Access genericDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 70 1 4 Defines the state of the generic device DellStateSettings Read write Generic Device Status Name Object ID Description Syntax Access genericDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 70 1 5 Defines the status of the generic device DellStatus Read only Generic Device System Slot Index Reference Name Object ID Description Syntax Access genericDeviceSystemSlotIndexReference 1 3 6 1 4 1 674 10892 1 1100 70 1 6 Defines the index of the system slot into which this generic device is plugged DellO bjectRange Read only Generic Device Type Name Object ID Description Syntax Access genericDeviceTyp 1 3 6 1 4 1 674 10892 1
58. Syntax DellM emoryD eviceType See Table 14 16 Access Read only Memory Device Location Name Name Object ID Description Syntax Access memoryDeviceLocationName 1 3 6 1 4 1 674 10892 1 1100 50 1 8 Defines the location name of the memory device DellString Read write DeviceGroup 285 Memory Device Error Count K NOTE M emory Device Failure M odes on page 289 has now replaced this attribute Memory Device Error Count should no longer be used If you use the M emory Device Error Count attribute the value returned is always zero and using the attribute has no effect Name Object ID Description Syntax Access memoryDeviceErrorCount 1 3 6 1 4 1 674 10892 1 1100 50 1 9 Defines the total number of Error Checking and Correction ECC errors detected by the memory device W riting a 0 zero to this variable resets the devices error counts DellSigned32BitRange Read write Memory Device Bank Location Name Name Object ID Description Syntax Access memoryDeviceBankLocationName 1 3 6 1 4 1 674 10892 1 1100 50 1 10 Defines the bank location name of the memory device DellString Read only Memory Device Type Details Name Object ID Description Syntax Access memoryDeviceTypeDetails 1 3 6 1 4 1 674 10892 1 1100 50 1 11 Defines the detailed type of the memory device DellM emoryD eviceTypeD etails See Table 13 17 Read only 286 Device Group Memory Device Form Factor Name me
59. Syntax DellRemoteSN M PTrapStateSettings See Table 20 19 Access Read write Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 6 Description Defines the status of this remote access SNM P trap destination Syntax DellStatus Access Read only Remote Access Group 497 Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 7 Description Defines the IP address of this remote access SN MP trap destination Syntax pAddress Access Read write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 8 Description Defines the community for traps sent to this remote access SNMP trap destination Syntax DisplayString SIZE 0 31 Access Read write Remote SNMP Trap Filter DRS Events Mask Name remoteSNMPTrapFilterDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 9 Description Defines the DRS events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write Remote SNMP Trap Filter System Events Mask Name remoteSNMPTrapFilterSysEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 10 Description Defines the system events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write 498 Remote Access Group Remote SNMP Trap Filter
60. Syntax StringType Access Read only RAC URL Name racURL Object ID 1 3 6 1 4 1 674 10892 5 1 1 6 0 Description This attribute defines the out of band UI URL of a remote access card Syntax StringType Access Read only iDRAC7MIB 74 RAC Type Name racType Object ID 1 3 6 1 4 1 674 10892 5 1 1 7 0 Description This attribute defines the type of a remote access card Syntax RacTypeEnum Access Read only RAC Firmware Version Name racFirmwareVersion Object ID 1 3 6 1 4 1 674 10892 5 1 1 8 0 Description This attribute defines the firmware version of a remote access card Syntax StringType Access Read only Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides K NOTE This Chassis information is only available for modular blade systems For Rack and Tower systems the information is empty Currently there is just one object under the Chassis Information Group Chassis Service Tag Name chassisServiceTag Object ID 1 3 6 1 4 1 674 10892 5 1 2 1 0 Description This attribute defines the service tag of the enclosing chassis Syntax StringType Access Read only System Information Group The System Information Group objects provide information about the system in which the iD RAC resides 742 iDRAC7 MIB System Fully Qualified Domain Name Name systemFQDN Object ID 1 3 6 1 4 1 674 10892 5 1 3 1 0 Description This attrib
61. The processor family is PA RISC deviceFamilyIsPA RISC8500 145 The processor family is PA RISC 8500 deviceFamilyIsPA RISC8000 146 The processor family is PA RISC 8000 deviceFamilyIsPA The processor family is PA RISC RISC7300LC 147 7300LC deviceFamilyIsPA RISC7200 148 Theprocessor family is PA RISC 7200 deviceFamilyIsPA The processor family is PA RISC RISC7100LC 149 7100LC deviceFamilyIsPA RISC7100 150 The processor family is PA RISC 7100 deviceFamilyIsv30 160 The processor family is V30 deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n3200 161 Intel Xeon processor 3200 Series Device Group 329 Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n3000 162 Xeon processor 3000 Series deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n5300 163 Intel Xeon processor 5300 Series deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n5100 164 Xeon processor 5100 Series deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n5000 165 Xeon processor 5000 Series deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel nLV 166 Xeon processor LV deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel nU
62. acSwitchIsON 64 The power supply is indicating that the AC power switch is on onlineandAcSwitchIsON The power supply is online and indicating that the 66 AC power supply switch capability is activated acPowerIsON 128 The power supply is indicating that the AC power ison onlineAndAcPowerIsON The power supply is online and indicating that the 130 AC power is on 186 Power Group Table 9 2 Power Supply State Settings Unique continued Variable Name De 1 1PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value onlineAndPredictiveFail The power supply is online and indicating that it ure 210 has a problem acPowerAndSwitchAreOn The power supply is online and OK PowerSupplyIsOnIsOkAnd Online 242 Table 9 3 Power Supply Type Definitions Variable Name De 1 1PowerSupplyType Data Type Integer Possible Data Values Meaning of Data Value powerSupplyTypelIsOther 1 The power supply type is not one of the following powerSupplyTypelIsUnknown 2 The power supply type is unknown not known or not monitored powerSupplyTypelIsLinear 3 The power supply type is a linear power supply powerSupplyTypelIsSwitching 4 The power supply type is a switching power supply powerSupplyTypelIsBattery 5 The power supply type is a battery powerSupplyTypelIsuUPS 6 The power supply type is an uninterruptable power supply powerS
63. continued Type of Definition See Server Administrator standard data types that specify Appendix A Standard Data variable values in this reference guide Type Definitions on page 789 SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide T his guide provides definitions for all essential terms used in describing the Server Administrator M I Bs For definitions on all essential terms and acronyms see the Glossary available on the D ell Support website at support dell com manuals SNMP Master Agent Typically the SNM P agent on a managed system consists of one SNM P master agent and zero or more SNM P extension agents T his SNM P agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNM P agent and isinvisible to SNMP management applications The SNM P master agent is responsible for receiving SNM P request protocol messages from SN M P management applications and sending SNM P response protocol messages As part of processing SNM P request protocol messages the SNMP master agent typically communicates with one or more SNMP extension agents T his communication does not involve standard SN M P protocol messages The SNM P master agent uses an extension protocol that shields the SNM P extension agent from the standard SNM P protocol messages T he extension protocol also provides a way for SNM P extension agents t
64. describes the connections between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found Virtual Disk Table This table describes available properties for each virtual disk on the managed system The following object sets up the Virtual Disk Table Name virtualDiskTable Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 Description Defines the virtual disk table Syntax SEQUENCE OF VirtualD iskE ntry Access Not accessible 656 l Storage M anagement Group Virtual Disk Entry Name virtualDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 Description Defines the virtual disk table entry Syntax VirtualD iskE ntry Access Not accessible Index virtualD iskN umber Virtual Disk Number Name virtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 1 Description Identifies the instance number of the virtual disk entry Syntax Integer Access Read only Virtual Disk Name Name virtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 2 Description Identifies the virtual disk s label generated by Storage M anagement or entered by the user Syntax DisplayString Access Read only Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 3 Description Identifies the device
65. deviceSRAMTypelIsUnknown 2 Device SRAM type is unknown deviceSRAMTypeIsNonBurst 3 Device SRAM type is nonburst deviceSRAMTypelIsBurst 4 Device SRAM type is burst deviceSRAMTypelIsPipeBurst 5 Device SRAM type is pipeburst deviceSRAMTypelIsSynchronous 6 Device SRAM type is synchronous deviceSRAMTypelIsAsynchronous 7 Device SRAM type is asynchronous Table 14 15 Memory Device Type Form Factor Variable Name De 1 1MemoryDeviceFormFactor Data Type Integer Possible Data Values Meaning of Data Value deviceFormFactorIsOther 1 Device form factor is not one of the following 338 Device Group Table 14 15 Memory Device Type Form Factor continued Variable Name Del 1MemoryDevic Data Type Integer FormFactor Possible Data Values Meaning of Data Value deviceFormFactorIsUnknown 2 Device form factor is unknown deviceFormFactorIsSIMM 3 Device form factor isSIMM deviceFormFactorIsSIP 4 Device form factor is SIP deviceFormFactorIsAChip 5 Device form factor is a chip deviceFormFactorIsDIP 6 Device form factor is DIP deviceFormFactorIsZIP 7 Device form factor is ZIP deviceFormFactorIsAProprietaryCard Device form factor is a proprietary 8 card deviceFormFactorIsDIMM 9 Device form factor isDIMM deviceFormFactorIsTSOP 10 Device form factor is TSOP deviceFormFactorIsARowOfChips 11 Device for
66. that one of the components l i of the redundancy unit has Chassis location lt N ame of failed but the unit is still chassis gt redundant T he redundancy Previous redundancy state was unit location chassis lt State gt location and previous Number of devices required for deol state are full redundancy lt Number gt P Redundancy Lost 1306 Redundancy lost Warningor A redundancy sensor in the Redundancy unit lt Redundancy Error specified system detected location in chassis gt depending that one of the components i on the in the redundant unit has Chassis location lt N ame of number of been disconnected has chassis gt units that failed or is not present The Previous redundancy state was are redundancy unit location lt State gt functional chassis location and Number of devices required for full redundancy lt Number gt previous redundancy state are provided Traps 709 Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis Table 27 9 Power Supply Traps TrapID Description Severity Cause 710 Power Supply Normal 1352 Power supply returned to normal Information Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If
67. 0 M deviceFamilyIsAMDAthlon64 131 The processor family is AM D Athlon 64 deviceFamilyIsAMDOpteron 132 The processor family is AM D Opteron deviceFamilyIsAMDSempron 133 The processor family is AM D Sempron deviceFamilyIsAMDTurion64Mobile The processor family isAM D Turion 64 134 M obile Technology deviceFamilyIsDualCoreAMDOpter The processor family is D ual C ore on 135 AMD Opteron 328 Device Group Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon64X2Dual The processor family is AM D Athlon Core 136 64 X2 Dual Core deviceFamilyIsAMDTurion64X2Mob The processor family isAM D Turion 64 ile 137 X2 M obile Technology deviceFamilyIsQuadCoreAMDOpter The processor family is Quad C ore on 138 AMD Opteron deviceFamilyIsThirdGeneration Theprocessor family is third AMDOpteron 139 generation AMD Opteron deviceFamilyIsAMDPhenomFXQuadc The processor family is AMD Phenom ore 140 FX Quad Core deviceFamilyIsAMDPhenomx4Quadc The processor family is AMD Phenom ore 141 X4 Quad C ore deviceFamilyIsAMDPhenomX2Dualc The processor family is AM D Phenom ore 142 X2 Dual Core deviceFamilyIsAMDAthlonX2Dualc The processor family is AM D Athlon ore 143 X2 Dual Core deviceFamilyIsPA RISC 144
68. 1 2 Description Defines the index one based of the remote access hardware used by this remote access user Syntax DellObjectRange Access Read only Remote User Admin User Index Name remoteUserAdminUserIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 3 Description Defines the index one based of this remote access user Syntax DellO bjectRange Access Read only Remote User Admin State Capabilities Name remoteUserAdminStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 4 Description Defines the state capabilities for this remote access user Syntax DellRemoteU serAdminStateC apabilities See Table 20 12 Access Read only 488 Remote Access Group Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 5 Description Defines the state settings for this remote access user Syntax DellRemoteU serAdminStateSettings See Table 20 13 Access Read write Remote User Admin Status Name remoteUserAdminStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 6 Description Defines the status for this remote access user Syntax DellStatus Access Read only Remote User Admin User Name Name remoteUserAdminUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 7 Description Defines the user name for this remote access user Syntax DisplayString SIZE 0 19 Access Read write Remote User Admin User Password Name Name remoteUserAdminUserPasswordName Object ID
69. 1 674 10892 1 300 80 Description Defines the Baseboard Table Syntax SEQUENCE OF BaseBoardTableE ntry Access Not accessible Chassis Information Group 103 Baseboard Table Entry Name baseBoardTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 Description Defines the Baseboard Table entry Syntax BaseBoardTableE ntry Access Not accessible Index baseBoardC hassisI ndex baseBoard ndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Baseboard Index Name baseBoardIndex Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 2 Description Defines the index one based of the base board Syntax DellObjectRange Access Read only Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 3 Description Defines the state capabilities of the baseboard Syntax D ellStateC apabilities Access Read only 104 Chassis Information Group Baseboard State Settings Name Object ID Description Syntax Access baseBoardStateSettings 1 3 6 1 4 1 674 10892 1 300 80 1 4 Defines the state settings of the baseboard DellStateSettings Read write Baseboard Status Name Object ID Description Syntax Access baseBoardStatus 1 3 6 1 4 1 674 10892 1 300 80 1 5 Defines the status of the baseboard DellStatus Read only B
70. 100 1 Description Defines the managed system services device table entry Syntax M anagedSystemServicesD eviceTableE ntry Access Not accessible Index managedSystemServicesD eviceC hassisl ndex managedSystemServicesD evicel ndex Managed System Services Device Chassis Index Name managedSystemServicesDeviceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 1 Description Defines the index one based of the chassis that contains the managed system services device Syntax DellO bjectRange Access Read only Device Group 311 Managed System Services Device Index Name Object ID Description Syntax Access managedSystemServicesDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 100 1 2 Defines the index one based of the managed system services device DellO bjectRange Read only Managed System Services Device Status Name Object ID Description Syntax Access managedSystemServicesDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 100 1 3 Defines the status of the managed system services device DellStatus Read only Managed System Services Device Type Name Object ID Description Syntax Access 312 managedSystemServicesDeviceTyp 1 3 6 1 4 1 674 10892 1 1100 100 1 4 Defines the type of the managed system services device DellM anagedSystemServicesD eviceType See Table 14 25 Read only Device Group Managed System Services Device Storage Present Name managedSystemServicesDeviceStorage
71. 10892 1 200 10 1 7 Defines the status of all power units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power unit T he first byte returned represents the status of the first power unit the second byte returned represents the status of the second power unit and so on The bytes have the same definition type as D ellStatusR edundancy Octet String Size 1 128 Read only 53 System State Group System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 8 Description Definesthe state of all power supplies in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific power supply The first byte returned represents the state of the first power supply the second byte returned represents the state of the second power supply and so on The bytes have the same definition type as D ellStateSettings Syntax Octet String Size 1 128 Access Read only System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 9 Description Defines the status of all power supplies in this chassis Syntax DellStatus Access Read only System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1
72. 176 e Power Profile Table on page 182 Power Unit Table Name powerUnitTable Object ID 1 3 6 1 4 1 674 10892 1 600 10 Description Defines the Power Unit Table Syntax PowerU nitTableE ntry Access Not accessible Power Group 151 Power Unit Table Entry Name powerUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 Description Defines the Power Unit Table entry Syntax DellO bjectRange Access Read only Index powerU nitchassis l ndex powerU nitl ndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Power Unit Index Name powerUnit Index Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 2 Description Defines the index of the power unit in this chassis Syntax DellObjectRange Access Read only Power Unit State Capabilities Name powerUnitStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 3 Description Defines the capabilities of the power unit Syntax DellStateC apabilities Access Read only 152 Power Group Power Unit State Settings Name Object ID Description Syntax Access powerUnitStateSettings 1 3 6 1 4 1 674 10892 1 600 10 1 4 Defines the state and settings of the power unit DellStateSettings Read write Power Unit Redundancy Status Name Object ID Description Syntax Access powerUnitRedundancyStatus 1 3 6 1 4 1 674 108
73. 2 The monitor port connector type is unknown connectorPor tTypeIsDB15PinMale 3 The monitor port connector type isamale DB 15 connectorPor tTypeIsDB15PinFemale 4 The monitor port connector type isa female D B 15 PortGroup 259 Table 13 6 SCSI Port Connector Types Variable Name De11SCSIPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelIsOther 1 The SCSI port connector type is not one of the following connectorPortTypelIsUnknown 2 The SCSI port connector type is unknown connectorPortTypeIsDIN25pin 3 The SCSI port connector type isaDIN 25 pin connectorPortTypeIsDIN50pin 4 The SCSI port connector type isaDIN 50 pin connectorPortTypeIsDIN68pin 5 TheSCSI port connector type isaDIN 68 pin 260 Port Group Device Group The Device Group provides information about different types of pointing keyboard processor cache memory and peripheral component interconnect PCI devices Variables in this group cover information about type settings configuration manufacturer address or location and if applicable the speed of the device Device Tables The following management information base MIB tables define objects in the Device Group e Pointing Device Table on page 262 e Keyboard D evice Table on page 264 e Processor D evice Table on page 267 e Processor D ev
74. 2 3 1 7 Description Defines the blade subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only Dell Remote Access Controller Out of BandGroup 697 DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 9 Description Definesthe CMC health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsChassisFrontPanelAmbientTemperature Name drsChassisFrontPanelAmbientTemperatur Object ID 1 3 6 1 4 1 674 10892 2 3 1 10 Description Defines the ambient temperature reading in degrees C elsius for the chassis front panel controller Syntax D ellTemperatureR eading Access Read only 698 Dell Remote Access Controller Out of Band Group DRsCMAmbientTemperature Name Object ID Description Syntax Access drsCMCAmbientTemperatur 1 3 6 1 4 1 674 10892 2 3 1 11 Defines the ambient temperature reading in degrees C elsius for the chassis management card DellTemperatureR eading Read only DRsCMProcessorTemperature Name drsCMCProcessorTemperatur Object ID 1 3 6 1 4 1 674 10892 2 3 1 12 Description Defines the temperature reading in degrees C elsius for the c
75. 20 Baseboard M anagement C ontroller Group provides information about the Baseboard M anagement C ontroller BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BM C Introduction 1900 Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 26 Traps defines the types of alerts that can be sent to report the 5000 status of critical components Server Administrator Remote Access MIB The Server Administrator Remote Access M B filename dcs3rmt mib provides in band information about remote access hardware that may be present in your system The Server Administrator Remote Access M IB structures its MIB objects into groups of scalar objects or M IB tables that provide related information Table 1 3 describes each Server Administrator Remote Access M IB group and lists the MIB group number assigned to the M IB group The Server Administrator Remote Access M IB groups are identified by the SNM P OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt M IB group number gt is the MIB group number assigned to the M IB group See the relevant section for more information about the M IB objects defined in a M IB group Table 1 3 Server Administrator Remote Access MIB Sections in This Guide Section Topic MIB Group
76. 3 6 1 4 1 674 10892 1 1600 20 1 4 Description Specifies whether the service contract for this system was renewed Syntax DellBoolean Access Read write COO Service Contract Type Name Name cooServiceContract TypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 5 Description Defines the name of the service contract type for this system Syntax DellC ostofO wnershipString Access Read write COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 6 Description Defines the name of the service contract provider for this system Syntax DellC ostofO wnershipString Access Read write Costof Ownership Group 449 COO Cost Event Log Table TheCOO Cost Event Log Table provides M IB objects that allow you to track the duration and type of events that are logged for a particular system Name cooCostEventLogTable Object ID 1 3 6 1 4 1 674 10892 1 1600 30 Description Defines the COO Cost Event Log Table Syntax SEQUENCE OF COO CostEventL ogTableE ntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 Description Defines the COO Cost Event Log Table entry Syntax cooC ostE ventL ogTableE ntry Access Not accessible Index cooC ostE ventL ogchassis ndex cooC ostE ventL ogl ndex COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1 3 6 1 4 1 674 10892
77. 3 6 1 4 1 674 10892 1 1900 10 1 9 Defines the Globally UniqueID GUID of the BMC Octet String SIZE 16 Read only bmcType 1 3 6 1 4 1 674 10892 1 1900 10 1 10 Defines the type of the BMC DellM anagementC ontrollerType Read only BMC Module Name Name Object ID Description Syntax Access bmcModuleName 1 3 6 1 4 1 674 10892 1 1900 10 1 11 Defines the module name for the BMC The module name is present only on certain systems such as modular systems DellString Read only 534 Baseboard M anagement Controller Group BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 12 Description Defines the Pv4 URL for the BMC The URL isnot present on all systems Syntax DisplayString SIZE 0 1024 Access Read only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 13 Description Defines the IPv6 URL for the BMC The URL is not present on all systems Syntax DisplayString SIZE 0 1024 Access Read only Baseboard Management Controller Serial Interface Table Name bmcSerialInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 20 Description Defines the BMC Serial Interface Table Syntax SEQUENCE OF BmcSeriallnterfaceTableE ntry Access Not accessible Baseboard Management Controller Group 535 BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 Description Defines the BM
78. 30 1 18 Description Defines the number of processor cores enabled for the processor device Syntax DellUnsigned32BitRange Access Read only Processor Device Thread Count Name processorDeviceThreadCount Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 19 Description Defines the number of processor threads detected for the processor device Syntax DellUnsigned32BitRange Access Read only 272 Device Group Processor Device Characteristics Name Object ID Description Syntax Access processorDeviceCharacteristics 1 3 6 1 4 1 674 10892 1 1100 30 1 20 This attribute defines characteristics of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one NOTE Bits 2 15 need to be examined in the context of bit 1 If bit Lis set the processor characteristics are unknown and bits 2 15 cannot be used to determine if the functions associated with the bits are supported Bit Position Meaning if Set Bit 0 Reserved Bit 1 Unknown Bit 2 64 bit capable Bit 3 15 Reserved DellUnsigned16BitRange Read only Processor Device Extended Capabilities Name Object ID Description Syntax Access processorDeviceExtendedCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 21 This attribute defines extended capabilities of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position M eaning if Set
79. 4 1 674 10892 1 1700 50 1 4 Description Defines the state capabilities of this remote access dial in user Syntax DellRemoteUserD iall nStateC apabilities See Table 20 25 Access Read only Remote Access Group 505 Remote User Dial In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 5 Description Defines the state settings of this remote access dial in user Syntax DellRemoteU serD iall nStateSettings See Table 20 26 Access Read write Remote User Dial In Configuration Status Name remoteUserDialInCfgStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 6 Description Defines the status of this remote access dial in user Syntax DellStatus Access Read only Remote User Dial In Configuration PPP Username Name remoteUserDialInCfgPPPUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 7 Description Defines the PPP user name of this remote access dial in user Syntax DisplayString SIZE 0 15 Access Read write Remote User Dial In Configuration PPP User Password Name Name remoteUserDialInCfgPPPUserPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 8 Description Defines the PPP password of this remote access dial in user Syntax DisplayString SIZE 0 15 Access Read write 506 Remote Access Group Remote User Dial In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 50
80. 4 1 674 10892 1 200 10 1 48 Defines the combined status of all redundant memory units of this chassis DellStatus Read only System State Redundant Memory Unit Status List Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 49 Lists the status of each redundant memory unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a redundant memory unit The first byte returned represents the status of the first redundant memory unit and so on The bytes have the same definition type as DellStatus Octet String Size 1 128 Read only 67 System State Group System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 50 Description Defines the combined status of all processor devices of this chassis Syntax DellStatus Access Read only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 51 Description Lists the status of each processor device of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device The first byte returned represents the status of the first processor device and so on The bytes have the same definition type as D ell
81. 41 Description Defines the chassis reseller contact information name Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Product Name Name chassisResellerProductName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 42 Description Defines the chassis reseller product name Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller System ID Name chassisResellerSystemID Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 43 Description Defines the chassis reseller system ID 82 Chassis Information Group Name chassisResellerSystemID Syntax DellUnsigned16BitRange Access Read only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 44 Description Defines the capabilities of the NMI button control function Syntax DellN M IButtonC ontrolC apabilities See Table 6 18 Access Read only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 45 Description Defines the current reading and allows setting of the NM I button control hardware Syntax DellN M IButtonC ontrolSettings See Table 6 19 Access Read write Chassis System Properties Name chassisSystemProperties Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 46 Description Defines the properties of the system Syntax DellSystemProperties See Table 6 20 Access Read only 83 Chassis Inf
82. 674 10893 1 20 130 1 1 35 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax DisplayString Access Read only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 36 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Storage Management Group 573 Name controllerBatteryChargeCount Access Read only Controller Roll Up Status Name controllerRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 37 Description Indicates severity of the controller state This is the combined status of the controller and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Controller Component Status Name controllerComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 38 Description _ ndicatesthe status of the controller itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 574 Storage Management Group Controller Nexus ID Name Object ID Description Syntax Access controllerNexusID 1 3 6 1 4 1 674 10893 1 20 130 1 1 39 Durable unique ID for this controller DisplayString Read only Controller Alarm State Na
83. 7 This entry is obsolete T his setting is not supported by fans managed under Storage M anagement DisplayString Read only Fan Probe Minimum Critical Name Object ID Description Syntax Access fanProbeMinimumCritical 1 3 6 1 4 1 674 10893 1 20 130 7 1 8 This entry is obsolete T his setting is not supported by fans managed under Storage M anagement DisplayString Read only Fan Probe Maximum Warning Name Object ID Description Syntax Access fanProbeMaximumWarning 1 3 6 1 4 1 674 10893 1 20 130 7 1 9 This entry is obsolete T his setting is not supported by fans managed under Storage M anagement DisplayString Read only Fan Probe Maximum Critical Name Object ID Description Syntax Access fanProbeMaximumCritical 1 3 6 1 4 1 674 10893 1 20 130 7 1 10 This entry is obsolete T his setting is not supported by fans managed under Storage M anagement DisplayString Read only Storage Management Group 621 Fan Probe Current Value Name fanProbeCurrValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 11 Description Identifies the current speed of the fan Syntax DisplayString Access Read only Fan1 Part Number Name fanlPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 12 Description Identifies the part number of the fan in the enclosure Syntax DisplayString Access Read only Fan 2 Part Number Name fan2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 13
84. 7 Read only Chassis HD Fault Clear Control Settings Name Object ID Description Syntax Access chassisHDFaultClearControlSettings 1 3 6 1 4 1 674 10892 1 300 10 1 27 Allows reset of the chassis hard drive fault LED DellH D FaultLEDC ontrolSettings See Table 6 8 Read write 78 Chassis Information Group Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 28 Description Specifies whether the chassis front panel LED can be set to flash Syntax DellC hassisl dentifyC ontrolC apabilities See Table 6 9 Access Read only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 29 Description Causes the chassis front panel LED to flash Syntax DellC hassisl dentifyC ontrolSettings See Table 6 10 Access Read write Chassis Lock Present Name chassisLockPresent Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 30 Description Specifies whether a chassis lock is present on the chassis Syntax DellBoolean Access Read only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 31 Description Defines the capabilities of the host control object Syntax DellH ostC ontrolC apabilities See Table 6 11 Access Read only Chassis Information Group 79 Chassis Host Control Settings Unique Name chassishostC
85. 7 Hardware Configuration Traps TrapID Description Category SubCategory Severity Hardware Configuration Information 2331 Hardware configuration System Hardware Informational information Health Config Hardware Configuration Warning 2330 Hardware configuration System Hardware M inor warning Health Config Hardware Configuration Failure 2329 Hardware configuration System Hardware Critical failure or critical event Health Config Table 29 8 Memory Device Traps TrapID Description Category SubCategory Severity Memory Device Information 2267 Memory device System Memory Informational informational event Health Memory Device Warning 2266 Memorydevicestatusis System Memory Minor noncritical Health Memory Device Failure 752 iDRAC7 MIB TrapID Description Category SubCategory Severity 2265 Memory device statusis System Memory Critical critical Health iDRAC7MIB 753 Table 29 9 NIC Traps TrapID Description Category SubCategory Severity Network Information 2091 Network information System NIC Config Informational Health Network Warning 2090 Network warning System NIC Config Minor Health Network Failure 2089 Network failure or System NIC Config Critical critical event Health Table 29 10 Operation System OS Event Traps TrapID Description Category SubCategory Severity OS Information 2411 An OS graceful stop System OS Event Informational occurred or an O
86. Access Not accessible Index channelNumber Channel Number Name channelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 1 Description Identifies the instance number of the channel entry Syntax Integer Access Read only Channel Name Name channelName Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 2 Storage Management Group 583 Name channelName Description Identifies the name of the channel as represented in Storage M anagement The name includes the word channel and the instance For example C hannel 1 Syntax DisplayString Access Read only Channel State Name channelState Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 3 Description Identifies the current state of this channel Possible states 0 Unknown 1 Ready The 1 0 has resumed 2 Failed 3 Online 4 Offline The I O has paused 6 Degraded Syntax Integer Access Read only Channel Severity Name channelSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 4 Description This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only 584 Storage Management Group Channel Termination Name Object ID Description Syntax Access channelTermination 1 3 6 1 4 1 674 10893 1 20 130 2 1 5 Identifies the type of SCSI termination on this channel Termination is required for proper operation of this channel Possible values 1 Wide Termination 16
87. BMC DellO bjectRange Read only BMC State Capabilities Name Object ID Description Syntax Access bmcStateCapabilities 1 3 6 1 4 1 674 10892 1 1900 10 1 3 Defines the state capabilities of the BMC DellStateC apabilities Read only 532 Baseboard M anagement Controller Group BMC State Settings Name bmcStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 4 Description Defines the state settings of the BMC Syntax DellStateSettings Access Read write BMC Status Name bmcStatus Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 5 Description Defines the status of the BMC Syntax DellStatus Access Read only BMC Display Name Name bmcDisplayName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 6 Description Defines the display name of the BMC Syntax DellString Access Read only BMC Description Name Name bmcDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 7 Description Defines the description of the BMC Syntax DisplayString SIZE 0 255 Access Read only Baseboard Management Controller Group 533 BMC IPMI Version Name Name Object ID Description Syntax Access BMC GUID Name Object ID Description Syntax Access BMC Type Name Object ID Description Syntax Access bmcIPMIVersionName 1 3 6 1 4 1 674 10892 1 1900 10 1 8 Defines the version of the Intelligent Platform M anagement Interface IPM 1 specification that the BMC supports DellString Read only bmcGUID 1
88. Data Values Meaning of Data Value unknown 1 Network interface state is unknown enabled 2 Network interface is enabled enabledWithoutPXxXkE 4 Network interface is enabled without PXE Table 17 21 BIOS Setting Value Type Variable Name DellBIOSSettingValueType Data Type Integer Possible Data Values Meaning of Data Value integer 1 Value type is integer string 2 Value type is string enumeration 3 Value type is enumeration orderedList 4 Value type is ordered list 428 BIOS Setup Control Group Local Response Agent Group The Local Response Agent Group provides information about various attributes of your system s local response agent LRA The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type such as the loss of redundancy in a specific component or the elevation of temperature in a chassis Systems managers can configure the LRA to respond to an event type with a specific action W hen the condition of the critical component worsens the systems manager can escalate the response to make it more obvious to the operator For example when a voltage probe on a monitored machine reaches a warning condition the systems manager may want to notify the operator by causing the machine to beep W hen the voltage probe reaches failure the systems manager might want to ha
89. Defines the control settings for the diskette controller Syntax DellDisketteC ontrolSettingsU nique Access Read only Diskette Control Status Name disketteControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 5 Description Defines the status of the diskette controller Syntax DellStatus Access Read only Diskette Control Name Name disketteControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 6 Description Defines the setup BIOS name of the diskette controller Syntax DellString Access Read only Network Interface Control Table These M IB objects enable you to track the attributes of the NIC card for your system Name networkInterfaceControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 80 Description Defines the Network Interface C ontrol Table Syntax Networkl nterfaceC ontrolTableE ntry Access Not accessible 412 BIOS Setup Control Group Network Interface Control Table Entry Name Object ID Description Syntax Access Index networkInterfaceControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 80 1 Defines the Network Interface C ontrol Table entry Network nterfaceC ontrolTableE ntry Not accessible networkli nterfaceC ontrolchassisl ndex networkl nterfaceC ontroll ndex Network Interface Control Chassis Index Name Object ID Description Syntax Access networkInterfaceControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 1 Defines the index one based of this chassis DellObjectRange Read
90. DellBIO SSettingValueType Access Read only BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 6 Description Defines the current value of the BIOS setting 416 BIOS Setup Control Group Syntax Access DisplayString Read only BIOS Setting Pending Value Name Object ID Description Syntax Access biosSettingPendingValue 1 3 6 1 4 1 674 10892 1 1400 90 1 7 Defines the pending value of the BIOS setting DisplayString Read only BIOS Setting Default Value Name Object ID Description Syntax Access biosSettingDefaultValue 1 3 6 1 4 1 674 10892 1 1400 90 1 8 Defines the default value of the BIOS setting DisplayString Read only BIOS Setting Possible Values Name Object ID Description Syntax Access biosSettingPossibleValues 1 3 6 1 4 1 674 10892 1 1400 90 1 9 Defines the possible values of the BIOS setting DisplayString Read only BIOS Setting Display Order Name Object ID Description biosSettingDisplayOrder 1 3 6 1 4 1 674 10892 1 1400 90 1 10 Defines the recommended display order of the BIOS setting within its BIOS setting group BIOS Setup Control Group 417 Syntax DellUnsigned32BitRange Access Read only BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 11 Description Defines the display name of the BIOS setting group for the BIOS setting Syntax DisplayString
91. DellRemoteDialUpStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial up functionality has no state settings unknown 1 The dial up functionality state settings are unknown enabled 2 The dial up functionality is enabled notReadyCapable 4 The dial up functionality is in the not ready state dialInEnabled 8 The dial up functionality dial in feature is enabled dialOutEnabled 16 The dial up functionality dial out feature is enabled Remote Access Group 521 Table 20 23 Remote Dial Up State Settings continued Variable Name De 1 1RemoteDialUpStateSettings Data Type Integer Possible Data Values Meaning of Data Value dia 1InDHCPEnabled 32 Thedial up functionality uses DHCP to obtain an IP address for the dial in feature dia 64 lInAuthAnyEnabled The dial up functionality accepts any authentication type including clear text for the dial in feature dialInAuthEncrypted The dial up functionality uses only encrypted Enabled 128 passwords CHAP authentication type for the dial in feature dialInAuthMschapEnab The dial up functionality uses only M SC HAP led 256 authentication type for the dial in feature Table 20 24 Remote Dial Up Modem Dial Type Variable Name De 1 1RemoteDialUpModemDialType Data Type Integer Possible Data Values Meaning of Data Value
92. Description Defines the System Resource I O Port Table Syntax SEQUENCE OF SystemResourcelO PortTableE ntry Access Not accessible System Resource 1 0 Port Table Entry Name systemResourcelOPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 Description Defines the System Resource I O Port Table entry Syntax SystemResourcel O PortTableE ntry Access Not accessible Index systemR esourcel O Portchassisl ndex systemR esourcel O Portl ndex 134 System Resource Group System Resource I O Port Chassis Index Name Object ID Description Syntax Access systemResourcelOPortchassisIndex 1 3 6 1 4 1 674 10892 1 500 30 1 1 Defines the index one based of this chassis DellO bjectR ange Read only System Resource I O Port Index Name Object ID Description Syntax Access systemResourcelOPortIndex 1 3 6 1 4 1 674 10892 1 500 30 1 2 Defines the index one based of the system resource I O ports in this chassis DellO bjectR ange Read only System Resource 1 0 Port State Capabilities Name Object ID Description Syntax Access systemResourcelOPortStateCapabilities 1 3 6 1 4 1 674 10892 1 500 30 1 3 Defines the capabilities of the system resource I O port D ellStateC apabilities Read only System Resource 1 0 Port State Settings Name Object ID Description Syntax Access systemResourcelOPortStateSettings 1 3 6 1 4 1 674 10892 1 500 30 1 4 Defines the state and allows the setting of
93. Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller CO Operating System Controller Name controllerCO0OSController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 24 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax DisplayString Access Read only 570 Storage Management Group Controller CO Battery State Name controllerCO0BatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 25 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Port 0 World Wide Name Name controllerC1Port OWWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 26 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 27 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 28 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Storage Management Group 571 Controller C1 Target Name controllerClTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 2
94. Index Name Object ID Description Syntax Access powerSupplyIndex 1 3 6 1 4 1 674 10892 1 600 12 1 2 Defines the index of power supply DellObjectRange Read only Power Supply State Capabilities Unique Name Object ID Description Syntax Access powerSupplyStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 600 12 1 3 Defines the capabilities of the power supply DellPowerSupplyStateC apabilitiesU nique See Table 9 1 Read only Power Supply State Settings Unique Name Object ID Description Syntax Access powerSupplyStateSettingsUnique 1 3 6 1 4 1 674 10892 1 600 12 1 4 Defines the state and settings of the power supply D ellPowerSupplyStateSettingsU nique See Table 9 2 Read write Power Supply Status Name Object ID Description Syntax Access powerSupplyStatus 1 3 6 1 4 1 674 10892 1 600 12 1 5 Defines the status of the power supply DellStatus Read only PowerGroup 155 Power Supply Output Watts Name Object ID Description Syntax Access Power Supply Type Name Object ID Description Syntax Access powerSupplyOutputWatts 1 3 6 1 4 1 674 10892 1 600 12 1 6 Defines the maximum sustained output wattage of the power supply in tenths of watts DellSigned32BitRange Read only powerSupplyType 1 3 6 1 4 1 674 10892 1 600 12 1 7 Defines the type of power supply DellPowerSupplyType See Table 9 3 Read only Power Supply Location Name Name Object ID Description Syntax
95. Meaning of Data Value systemSlotHotPlugCanSignal Attention 8 The system slot attention state and corresponding LED can be set HotP 16 systemSlo PowerFaul lugCanSignal Power on fault and corresponding LED can be detected due to a short or overcurrent systemSlotHotPlugCanSignal AdapterPresent 32 Adapter card present in slot may not be powered can be detected systemSlotHotPlugCanSignal PowerButtonPressed 64 The system slot power button can be pressed to signal a toggle of the power state canSupportAllHotPlugCapabi lities 126 The system slot can support all hot plug capabilities systemSlotHotPlugIsUnknown 1 The system slot s capabilities are unknown systemSlotCanProvide5Volts 128 The system slot can providea 5 volt V supply systemSlotCanProvide3Point 3Volts 256 The system slot can provide a 3 3 V supply systemSlotCanSignallfShared 512 The system slot s opening if shared with another slot can be detected systemSlotCanSupportCard1l6 1024 The system slot can support PC Card 16 systemSlotCanSu 2048 pportCardBus The system slot can support CardBus systemSlotCanSu eo 4096 pportZoomvid The system slot can support Zoom Video systemSlotCanSupportModem RingResume 8192 The system slot can support modem ring resume systemSlotCanSuppo
96. Memory Device Failure Modes continued Variable Name De 1 1MemoryDeviceFailureModes Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value eccSingleBitCorrectionLoggingDisabled 8 Correctable Memory Event logging for memory device has been disabled deviceDisabledBySpareActivation 16 Memory device is disabled because of spare memory activation Table 14 20 Network Device Connection Status Variable Name De 1 1NetworkDeviceConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 0 Unable to determine connection status connected 1 M edia reports that device is connected disconnected 2 M edia reports that device is disconnected driverBad 3 Driver cannot be opened to determine status driverDisabled 4 D river is disabled hardwareInitalizing 10 Hardware is initializing hardwareResetting 11 H ardware is resetting hardwareClosing 12 H ardware is closing down hardwareNotReady 13 H ardware is not ready Device Group 343 Table 14 21 Network Device Teaming Flags Variable Name De 1 1NetworkDeviceTeamingFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value undefined 0 Teaming fl
97. Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 4 Description Defines the state of the memory device mapped address Syntax DellStateSettings Access Read write Memory Device Mapped Address Status Name memoryDeviceMappedAddressStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 5 Description Defines the status of the memory device mapped address Syntax DellStatus Access Read only 292 Device Group Memory Device Index Reference Name Object ID Description Syntax Access memoryDeviceIndexReferenc 1 3 6 1 4 1 674 10892 1 1100 60 1 6 Defines the index of the memory device s associated with this memory device mapped address DellO bjectRange Read only Memory Device Mapped Address Row Position Name Object ID Description Syntax Access memoryDeviceMappedAddressRowPosition 1 3 6 1 4 1 674 10892 1 1100 60 1 7 Defines the position of the referenced memory in a row of the memory device mapped address DellU nsigned32BitRange Read only Memory Device Mapped Address Interleave Position Name Object ID Description Syntax Access memoryDeviceMappedAddressInterleavePosition 1 3 6 1 4 1 674 10892 1 1100 60 1 8 Defines the position of the referenced memory in an interleave of the memory device mapped address DellU nsigned32BitRange Read only DeviceGroup 293 Memory Device Mapped Address Interleave Depth Name Object ID Description Syntax Access memoryDeviceMap
98. P Trap Destination Table entry Syntax RemoteSN M PTrapTableE ntry Access Not accessible Index remoteSN M PTrapC hassis ndex remoteSN M PTrapAdapterl ndex remoteSNM PTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellO bjectRange Access Read only Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 2 Description Defines the index one based of the remote access hardware that uses this SNMP trap destination Syntax DellO bjectRange Access Read only 496 Remote Access Group Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 3 Description Defines the index one based of this remote access SNMP trap destination Syntax DellO bjectRange Access Read only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 4 Description Defines the state capabilities of this remote access SN MP trap destination Syntax DellRemoteSN M PTrapStateC apabilities See Table 20 18 Access Read only Remote SNMP Trap State Settings Name remoteSNMPTrapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 5 Description Defines the state settings of this remote access SNMP trap destination
99. Password Name Name bSUCadministratorPasswordNewPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 30 Description Defines the setup BIOS name of the new administrator password To set a new administrator password you must have successfully set the current administrator password immediately preceding this password change Syntax DellString Access Read write 397 BIOS Setup Control Group BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 31 Description Defines the capabilities of user password control Syntax DellBIO SPasswordC ontrolC apabilitiesU nique Access Read only BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 32 Description Defines the control settings for user password control Syntax D ellB1 O SPasswordC ontrolSettingsU nique See Table 17 9 Access Read write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 33 Description Defines the status of the user password control Syntax DellStatus Access Read only BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 34 Description Defines the setup BIOS name of the current user password Syntax DellString Access Read
100. Port Connector Types Variable Name De 1 1KeyboardPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelIsOther 1 The keyboard port connector type is not one of the following connectorPortTypelsUnknown 2 The keyboard port connector type is unknown connectorPortTypeIsMiniDIN 3 The keyboard port connector typeisa mini DIN connectorPortTypelIsMicroDIN 4 The keyboard port connector typeis aMicroDIN connectorPortTypelsPS2 5 The keyboard port connector type is PS 2 connectorPortTypelIsInfrared 6 The keyboard port connector type is infrared connectorPortTypeIsHPHIL 7 The keyboard port connector type is H P HIL connectorPortTypeIsDB9 8 The keyboard port connector type is DB 9 connectorPortTypelIsAccessBusUSB 9 The keyboard port connector type is bus USB connectorPortTypelIsPC98 10 The keyboard port connector type is PC 98 256 Port Group Table 13 3 Processor Port Connector Types Variable Name De11ProcessorPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connec COL PortTypelsOther 1 The processor port connector type is not one of the following connec ROT PortTypeIsUnknown 2 The processor port connector type is unknown connec COL Port ypelIsDaughterdBoard 3 The processor port connector type is a daughter boar
101. PowerVault 221S enclosures Possible values 1 Enabled 2 Disabled 3 Not applicable Integer Read only Storage Management Group 561 Physical Devices Group The Physical Devices M IB group provides information about the devices managed by the Storage M anagement software and their relationships to each other The following M IB tables define objects and relationships connections among the objects 562 Controller Table describes available properties for each controller on the managed system C hannel Table describes available properties for each channel on the managed system Enclosure Table describes available properties for each enclosure on the managed system Array D isk Table describes available properties for each physical array disk on the managed system Array D isk Enclosure C onnection Table describes the connections between Fibre Channel array disks their enclosure and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found Array Disk C hannel C onnection Table describes the connections between SC SI array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found Fan
102. Read only Battery State Name batteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 4 Description Identifies the current state of battery Possible values 0 Unknown 1 0K 2 Failed 6 Degraded 7 Reconditioning 9 High 10 Low 12 Charging 21 Missing 36 Learning Syntax Integer Access Read only Storage Management Group 649 Battery Roll Up Status Name batteryRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 5 Description Severity of the battery state This is the combined status of the battery and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Battery Component Status Name batteryComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 6 Description T he status of the battery itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 650 Storage Management Group Battery Charge Count Name batteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 7 Description The number of charges that have been applied to the battery Syntax Integer Access Read only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 8 Description The maximum number of charges that can be applied to the battery S
103. Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessL ANC apabilities See Table 20 6 Access Read only Remote Access Group 481 Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessL AN Settings See Table 20 7 Access Read write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 16 Description Defines the host capabilities of the remote access hardware Syntax DellRemoteAccessH ostC apabilities See Table 20 8 Access Read only Remote Access Host Settings Name remoteAccessHostSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 17 Description Defines the host settings of the remote access hardware Syntax DellRemoteAccessH ostSettings See Table 20 9 Access Read write Remote Access Out of Band Simple Network Management Protocol SNMP Capabilities Name remoteAccessOutOfBandSNMPCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 18 Description Defines the out of band SNM P capabilities of the remote access hardware Syntax DellRemoteAccessO utO fBandSN M PC apabilities See Table 20 10 Access Read only 482 Remote Access Group
104. Sections in This Guide Section Topics MIB Group Numbers 10 User Security Group defines variables for creating and modifying user accounts 800 11 Remote Flash BIOS Group defines variables for updating the system s BIOS remotely 900 12 Port Group defines variables for major port types such as keyboard monitor small computer system interface SC SI Universal Serial Bus USB and parallel and serial ports 1000 13 Device Group defines variables for pointing keyboard processor cache memory and personal computer interface devices 1100 14 Slot Group defines variables for the system s slots 1200 15 M emory Group defines variables for the system s physical memory 1300 16 BIOS Setup Control Group defines variables for BIOS functions such as boot sequence speakers W ake on the local area network LAN diskettes ports and network interface controllers NIC 1400 17 Local Response Agent Group defines variables for global settings and actions T hese variables allow users to predetermine how the system responds to a particular type of event 1500 18 Cost of Ownership Group defines variables for tracking data on the system s service contract lease repair records trouble tickets and so on 1600 20 Cluster Group defines variables for systems that operate as a cluster 1800 21
105. Settings Variable Name De 1 1BTOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1 Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled 422 BIOS Setup Control Group Table 17 9 BIOS Password Control Settings continued Variable Name De 11B1TOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by a jumper Table 17 10 TPM Security Control Capabilities Variable Name De11TPMSecurityControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value of fCapable 1 TPM security can be O ff onWithPrebootMeasurementsCap TPM security can be On with Pre boot able 2 M easurements onWithoutPrebootMeasurements TPM security can be O n without Pre boot Capable 4 M easurements Table 17 11 TPM Security Control Setting Variable Name De11TPMSecurityControlSetting Data Type Integer Possible Data Values Meaning of Data Value off 0 TPM security is O ff onWithPrebootMeasurements 1 TPM security is On with Pre boot M easurements onWithoutPrebootMeasurements TPM security is On without Pre boot 2 M easurements BIOS Setup Control Group 423 Table
106. Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 25 Description Defines the control name of the boot sequence Syntax DellString Access Read only BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 26 Description Defines the capabilities of the administrator password control Syntax DellBIO SPasswordC ontrolC apabilitiesU nique Access Read only 396 BIOS Setup Control Group BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 27 Description Defines the settings for administrator password control Syntax D ellB1 O SPasswordC ontrolSettingsU nique See Table 17 9 Access Read write BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 28 Description Defines the status for administrator password control Syntax DellStatus Access Read only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 29 Description Defines the setup BIOS name for the current administrator password Syntax DellString Access Read write BIOS Setup Control Administrator Password New
107. State gt on the backplane board system board or drive carrier in the specified system exceeded its warning threshold T he sensor location chassis location previous state and temperature sensor value are provided Traps 699 Table 27 3 Temperature Probe Traps continued TrapID Description Severity Cause Temperature Probe Failure 1054 Temperature sensor detected a Error A temperature sensor failure value on the backplane Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature state lt State gt board system board or drive carrier in the specified system exceeded its failure threshold Thesensor location chassis location previous state and temperature sensor value are provided Temperature Probe Non recoverable 1055 Temperature sensor detected a Error non recoverable value Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature state lt State gt A temperature sensor on the backplane board system board or drive carrier in the specified system detecte
108. Storage Storage Informational Enclosr Storage Enclosure Warning 4338 Enclosure warning Storage Storage M inor Enclosr 762 iDRAC7 MIB TrapID Description Category SubCategory Severity Storage Enclosure Failure 4337 Enclosure failure Storage Storage Critical Enclosr iDRAC7MIB 763 Table 29 30 Fan Traps TrapID Description Category SubCategory Severity Storage Fan Information 4203 Fan information Storage Fan Event Informational Storage Fan Warning 4202 Fan warning Storage Fan Event M inor Storage Fan Failure 4201 Fan failure Storage Fan Event Critical Table 29 31 Physical Disk Traps TrapID Description Category SubCategory Severity Storage Physical Disk Information 4347 Physical disk Storage Physical Disk Informational information Storage Physical Disk Warning 4346 Physical disk warning Storage Physical Disk Minor Storage Physical Disk Failure 4345 Physical disk failure Storage Physical Disk Critical Table 29 32 Power Supply Traps TrapID Description Category SubCategory Severity Storage Power Supply Information 4235 Power supply Storage Power Supply Informational information Storage Power Supply Warning 4234 Powersupply warning Storage Power Supply Minor Storage Power Supply Failure 4233 Power supply failure Storage Power Supply Critical 764 iDRAC7 MIB Table 29 33 Storage Management Status Traps TrapID Description Category
109. Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Cluster Table Entry Name clusterTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 Description Defines the Cluster Table entry Syntax ClusterTableE ntry Access Not accessible Index clusterC hassisl ndex cluster ndex Cluster Group 527 Cluster Chassis Index Name clusterChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Cluster Index Name clusterIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 2 Description Defines the index one based of the cluster Syntax DellO bjectRange Access Read only Cluster State Capabilities Name clusterStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 3 Description Defines the state capabilities of the cluster Syntax DellStateC apabilities Access Read only Cluster State Settings Name clusterStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 4 Description Defines the state settings of the cluster Syntax DellStateSettings Access Read write 528 Cluster Group Cluster Status Name Object ID Description Syntax Access Cluster Type Name Object ID Description Syntax Access clusterStatus 1 3 6 1 4 1 674 10892 1 1800 10 1 5 Defines the status of the cluster DellStatus Read only clusterType 1 3 6 1 4 1 674 10892 1 1800 10 1 6 Defines the type of the cluster
110. System Resource Memory Table Name Object ID Description Syntax Access systemResourceMemoryTable 1 3 6 1 4 1 674 10892 1 500 40 Defines the System Resource M emory Table SEQUENCE OF SystemResourceM emoryTableE ntry Not accessible System Resource Memory Table Entry Name Object ID Description Syntax Access Index systemResourceMemoryTableEntry 1 3 6 1 4 1 674 10892 1 500 40 1 Defines the System Resource M emory Table entry SystemResourceM emoryTableE ntry Not accessible systemR esourceM emorychassislndex systemResourceM emoryl ndex System Resource Memory Chassis Index Name Object ID Description Syntax Access systemResourceMemorychassisIndex 1 3 6 1 4 1 674 10892 1 500 40 1 1 Defines the index one based of this chassis DellO bjectR ange Read only System Resource Group 137 System Resource Memory Index Name systemResourceMemoryIndex Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 2 Description Defines the index of system resource memory in this chassis Syntax DellO bjectRange Access Read only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 3 Description Defines the capabilities of this system resource memory Syntax DellO bjectRange Access Read only System Resource Memory State Settings Name systemResourceMemoryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 4 Description Defines the s
111. T he action number indexes are as follows 160 temperature failure action definition 168 cooling device failure action definition 172 voltage failure action definition 200 temperature warning action definition 202 voltage warning action definition 204 cooling device warning action definition 206 amperage failure action definition 208 amperage warning action definition 210 apower or cooling unit redundancy lost action definition 212 apower or cooling unit redundancy degraded action definition 214 power supply failed action definition 220 chassis intrusion action definition 228 memory device warning action definition 474 memory device failure action definition 1006 automatic system recovery ASR action definition 1353 power supply warning action definition 1553 log near full action definition 1554 log full action definition 1603 processor warning action definition 1604 processor failure action definition 1703 battery warning action definition 1704 battery failure action definition DellU nsigned16BitRange Read only LocalResponseAgentGroup 433 LRA Action Table User Application Name Name 1RAActionTableUserApplicationName Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 3 Description W hen the execute application value is set provides the following user assignable LRA information e Name of the user application executable path e File
112. V and shares a slot opening The adapter ison and the system slot is hot pluggable 356 Slot Group Table 15 3 System Slot Type Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsOther 1 The system slot type is not one of following systemSlot IsUnknown 2 The system slot type is unknown systemSlotIsISA 3 The system slot is Industry Standard Architecture ISA systemSlotIsMCA 4 The system slot is Micro C hannel Architecture MCA systemSlotIsEISA 5 Thesystem slot is Extended Industry Standard Architecture EISA systemSlotIsPCI 6 The system slot is Peripheral Component Interconnect PCI systemSlotIsPCMCIA 7 The system slot is compliant with the Personal Computer M emory Card International Association PCM CIA standards systemSlot IsVLVESA 8 The system slot is Very L ow Voltage Enterprise System Architecture VLVESA systemSlotIsProprietary 9 The system slot is proprietary systemSlotIsProcessorCard 10 The system slot is a processor card systemSlotIsProprietaryMemory 11 Thesystem slot is proprietary memory systemSlotIsIORiserCard 12 The system slot is an I O riser card systemSlot IsNuBUS 13 The system slot is a NuBus systemSlotIsPCI66MHz 14 The system slot is a PC166M Hz systemSlotIsAGP 15 The system slot is an Advanced Graphics Port AGP systemSlot Is
113. a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks Syntax DellM emoryD eviceF ailureM odes Access Read only Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 21 Description Defines the manufacturer of the memory device Syntax DellString Access Read only DeviceGroup 289 Memory Device Part Number Name Name Object ID Description Syntax Access memoryDevicePartNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 22 Defines the manufacturer s part number for the memory device DellString Read only Memory Device Serial Number Name Name Object ID Description Syntax Access memoryDeviceSerialNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 23 Defines the serial number of the memory device DellString Read only Memory Device Asset Tag Name Name Object ID Description Syntax Access memoryDeviceAssetTagName 1 3 6 1 4 1 674 10892 1 1100 50 1 24 Defines the asset tag of the memory device DellString Read only Memory Device Speed Name Name Object ID Description Syntax Access memoryDeviceSpeedNam 1 3 6 1 4 1 674 10892 1 1100 50 1 25 This attribute defines the speed of the memory device in string format with units specified in string DellString Read only 290 Device Group Memory Device Mapped Address Table Name Object ID Description Syntax
114. batteryReading 1 3 6 1 4 1 674 10892 1 600 50 1 6 Defines the reading of the battery DellBatteryReading see Table 9 15 Read only Power Group 175 Battery Location Name Name batteryLocationName Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 7 Description Defines the location of the battery Syntax DellString Access Read only Power Usage Table Name powerUsageTable Object ID 1 3 6 1 4 1 674 10892 1 600 60 Description Defines the Power U sage Table Syntax SEQUENCE OF PowerU sageTableE ntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 Description Defines the Power U sage Table Entry Syntax PowerU sageTableE ntry Access Not accessible Index powerU sageC hassisl ndex powerU sagel ndex Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only 176 l Power Group Power Usage Index Name Object ID Description Syntax Access powerUsageIndex 1 3 6 1 4 1 674 10892 1 600 60 1 2 Defines the index one based of the power usage information DellObjectRange Read only Power Usage State Capabilities Name Object ID Description Syntax Access powerUsageStateCapabilities 1 3 6 1 4 1 674 10892 1 600 60 1 3 Defines the state capabilities of the power usage information DellStateC a
115. bit 2 Narrow Termination 8 bit 3 Not Terminated Integer Read only Channel SCSI ID Name Object ID Description Syntax Access channelSCSIID 1 3 6 1 4 1 674 10893 1 20 130 2 1 6 Identifies the SCSI ID of the controller to which the channel belongs Integer Read only Storage Management Group 585 Channel Roll Up Status Name channelRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 7 Description Identifies the severity of the channel state T his is the combined status of the channel and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Channel Component Status Name channelComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 8 Description T he status of the channel itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 586 Storage Management Group Channel Nexus ID Name Object ID Description Syntax Access channelNexusID 1 3 6 1 4 1 674 10893 1 20 130 2 1 9 Durable unique ID for this channel DisplayString Read only Channel Data Rate Name Object ID Description Syntax Access channelDataRate 1 3 6 1 4 1 674 10893 1 20 130 2 1 10 Identifies the data rate of this channel DisplayString Read only Channel Bus Ty
116. bjectRange Read only Memory Device Port Index Name Object ID Description Syntax Access 236 memoryDevicePortIndex 1 3 6 1 4 1 674 10892 1 1000 40 1 2 Defines the index of the memory device port in this chassis DellO bjectRange Read only Port Group Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 3 Description Defines the capabilities of the memory device port Syntax DellStateC apabilities Access Read only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 4 Description Defines the state and settings of the memory device port Syntax D ellStateSettings Access Read write Memory Device Port Status Name memoryDevicePortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 5 Description Defines the status of the memory device port Syntax DellStatus Access Read only Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 6 Description Defines the security settings of the memory device port Syntax D ellPortSecurityState Access Read only PortGroup 237 Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 7 Description Defines the connector type of the memory device port Syntax DellM emoryD evicePortC onnectorType See Table 13 4 Access Re
117. case chassis multiSystemChassis 25 The chassis type is a multisystem chassis Chassis Information Group 109 110 Table 6 3 Connection Status Variable Name De 11ConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 2 The status of the chassis connection is unknown ok 3 The status of the chassis connection is OK failure 4 The status of the chassis connection is failure Table 6 4 Fan Control Capabilities Variable Name De 1FanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrhighSpeedCapable 6 The fan can beset to low or high speed Table 6 5 Front Panel LED Control Capabilities Variable Name De 11 LEDControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 TheLED control capabilities are unknown alertOnErrorCapable 2 TheLED control can be set to alert on an error condition alertOnWarningAndErrorCap TheLED control can be set to alert on an able 4 error and a warning condition alertOnWarningOrErrorCapa TheLED control can be set to alert on an ble 6 error or a warning condition Chassis Information Group Table 6 6 Front Panel LED Control S
118. chassis Alerts are sent to prevent unauthorized removal of parts from a chassis Table 27 7 Chassis Intrusion Traps TrapID Description Severity Cause Chassis Intrusion Normal 1252 Chassis intrusion returned to Information A chassis intrusion sensor normal in the specified system Sensor location lt Location in detected that a cover was chassis gt opened while the sytem i was operating but has Chassis location lt N ame of since been replaced The chassis gt sensor location chassis Previous state was lt State gt location previous state Chassis intrusion state lt Intrusion A sa aac ote state gt ate provided Chassis Intrusion Detected 1254 Chassis intrusion detected Error A chassis intrusion sensor Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Chassisintrusion state lt Intrusion state gt in the specified system detected that the system cover was opened while the system was operating The sensor location chassis location previous state and chassis intrusion state are provided Traps 707 Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components Fans and power supplies for example are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed Redundancy allows a second or
119. chassis Syntax DellO bjectRange Access Read only 252 Port Group USB Port State Capabilities Name Object ID Description Syntax Access uSBPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 90 1 3 Defines the capabilities of the USB port DellStateC apabilities Read only USB Port State Settings Name Object ID Description Syntax Access USB Port Status Name Object ID Description Syntax Access uSBPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 90 1 4 Defines the state and settings of the USB port D ellStateSettings Read write uSBPortStatus 1 3 6 1 4 1 674 10892 1 1000 90 1 5 Defines the state of the USB port DellStatus Read only USB Port Security State Name Object ID Description Syntax Access uSBPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 90 1 6 Defines the security settings of the USB port D ellPortSecurityState Read only PortGroup 253 USB Port Connector Type Name uSBPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 7 Description Defines the connector type of the USB port Syntax D ellU SBPortC onnectorType Access Read only USB Port Name Name uSBPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 8 Description Defines the name of the USB port Syntax DellString Access Read only USB Port BIOS Connector Type Name uSBPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 9 Description Defines the BIOS connector type of the USB port
120. completion code is unknown not known or not monitored complet ionCodelIsOK 3 This completion code completed successfully complet ionCodeIsBadImage 4 This completion code is a bad flash BIOS image completionCodeIsNoFileAccess 5 Flash BIOS could not be accessed complet ionCodeI sNotReady 6 Flash BIOS memory not ready completionCodeIsDisabled 7 Flash BIOS is currently disabled completionCodeIsNoBattery 8 A battery must be installed complet ionCodeIsNoChargedBattery 9 A fully charged battery must be installed complet ionCodeIsNoExternalPower 10 An external power adapter must be connected completionCodeIsNol12VoltSet 11 12 volts V could not be set complet ionCodeIsNo12VoltRemoval 12 12 V could not be removed completionCodeIsFlashMemoryFailed A flash memory failure occurred 13 completionCodeIsGeneralFailure 14 A general failure occurred completionCodeIsDataMiscompare 15 A data miscompare error occurred complet ionCodeIsNoImageFound 16 The flash BIOS image could not be found in memory completionCodeIsNoUpdatePerformed No update operation has been 17 performed Remote Flash BIOS Group 225 226 Remote Flash BIOS Group Port Group The Port Group provides information about the different types of ports that may be present in your system This management information base M IB group also provides information about the capabilities states and settings th
121. control volume is low medium 8 Speaker control volume is medium high 16 Speaker control volume is high Table 17 3 Network Interface NIF Wakeup on LAN Capabilities Unique Variable Name De 1 1NIFwakeonLanControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Setup BIOS Wakeup on LAN capabilities are unknown enableCapable 2 Setup BIOS is capable of enabling the NIF Wakeup on LAN addInCardCapable 4 Setup BIOS is capable of enabling Wakeup on LAN by option card onBoardCapable 8 Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF 419 BIOS Setup Control Group Table 17 3 Network Interface NIF Wakeup on LAN Capabilities Unique continued Variable Name De 1 1NIFwakeonLanControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value bothCapable 14 Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF Table 17 4 NIF Wakeup on LAN Control Settings Unique Variable Name De 1 1NIFwakeonLanControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 NIF Wakeup on LAN state is unknown enabled 2 NIF Wakeup on LAN is enabled addInCard 4 NIF Wakeup on LAN is by option card onBoard 8 NIF Wakeup on LAN is by integrated NIF addInCardOrOnBoard 12 NIF Wakeup on LAN is by option card
122. device type is Non volatile 4096 deviceTypeDetailIsRegistered The detailed device type is registered 8192 deviceTypeDetailIsNonRegister The detailed device type is non ed 16384 registered DeviceGroup 341 Table 14 18 Generic Device Type Variable Name De 1 1GenericDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypeIsUnknown 2 Device type is unknown deviceTypelIsAVideoDevice 3 Device type is a video deviceTypeIsASCSIController 4 Device type is a SCSI controller deviceTypeIsAnEthernetDevice 5 Devicetypeis Ethernet deviceTypeIsTokenRingDevice 6 Device type is token ring deviceTypeIsASoundDevice 7 Device type is sound Table 14 19 Memory Device Failure Modes Variable Name De 1 1MemoryDeviceFailureModes Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value 0 Memory device has no faults eccSingleBitCorrect ionWarningRate 1 Memory device has exceeded the Correctable M emory Event warning rate eccSingleBitCorrectionFailureRate 2 Memory device has exceeded the Correctable M emory Event failure rate eccMultiBitFault 4 Memory device has encountered an Uncorrectable M emory Event 342 Device Group Table 14 19
123. dial out destination is disabled or enabled notReady 4 The dial out destination isin the not ready state dialOutPPPAuthAnyEnabled 8 The dial out destination accepts any authentication type including clear text for PPP dialOutPPPAuthEncryptedEnabled 16 Thedial out destination uses only encrypted passwords authentication type for PPP dialOutPPPAuthMschapEnabled 32 T he dial out destination uses only M SC HAP authentication type for PPP Remote Access Group 525 526 Remote Access Group Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot Clustering enhances higher availability scalability and management Higher availability is achieved by using failover clusters in which resources can automatically move between two or more systems in the event of a failure Scalability is achieved by balancing the load of an application across several computer systems Simpler management is achieved by using virtual servers as opposed to managing each individual computer system Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster capabilities of the cluster type of cluster and name of the cluster Cluster Table The following table defines the attributes of the cluster Name clusterTable Object ID 1 3 6 1 4 1 674 10892 1 1800 10 Description Defines the Cluster Table
124. disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Array Disk Device Name Name arrayDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 25 Description Identifies the operating system device name for this disk Syntax DisplayString Access Read only Array Disk Nexus ID Name arrayDiskNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 26 Description Indicates the durable unique ID for this array disk Syntax DisplayString Access Read only 608 Storage Management Group Array Disk Part Number Name arrayDiskPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 27 Description Indicates the part number of the disk Syntax DisplayString Access Read only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 28 Description Indicates the specified SAS address if this is a SAS disk Syntax DisplayString Access Read only Array Disk Negotiated Speed Name Object ID Description Syntax Access arrayDiskNegotiatedSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 29 Indicates the speed at which the drive is actually running in MPS megabytes per second Integer Read only Array Disk Capable Speed Name Object ID Description Syntax Access arrayDiskCapableSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 30 I
125. error DellU nsigned32BitRange Read only MemoryGroup 381 Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1300 60 1 9 Description Defines the index one based of the Physical M emory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with Syntax DellO bjectRange Access Read only Memory Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 16 1 Physical Memory Array Location Variable Name De11PhysicalMemoryArrayLocation Data Type Integer Possible Data Values Meaning of Data Value memoryArrayLocationlIsOther 1 The memory array location is not one of the following memoryArrayUselIsUnknown 2 The memory array use is unknown memoryArrayUselsSystemMemory 3 The memory array is system memory memoryArrayUselsVideoMemory 4 The memory array is video memory memoryArrayUseIsFLASHMemory 5 The memory array is FLASH memory memoryArrayUselIsNonVolatileRAMMemory 6 The memory array is nonvolatile RAM memoryArrayUselsCacheMemory 7 382 Memory Group Thememory array is cache memory Table 16 1 Physical Memory Array Location continued Variable Name De11PhysicalMemoryArrayLocation Data
126. has four DIMM slots on the motherboard e physicalM emoryArrayl nU seN umberSockets 1 there is only one DIMM installed Memory Group 363 The following object sets up the Physical M emory Array Table Name physicalMemoryArrayTable Object ID 1 3 6 1 4 1 674 10892 1 1300 10 Description Defines the Physical M emory Array Table Syntax PhysicalM emoryArrayTableE ntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 Description Defines the Physical M emory Array Table entry Syntax PhysicalM emoryArrayTableE ntry Access Not accessible Index physicalM emoryArraychassis ndex physicalM emoryArrayl ndex Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Physical Memory Array Index Name physicalMemoryArrayIndex Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 2 Description Defines the index one based of the physical memory array in this chassis Syntax DellO bjectRange Access Read only 364 l M emory Group Physical Memory Array State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 10 1 3 Defines the capabilities of the physical memory array DellStateC apabilities Read only
127. has the same definition type as D ellStatus DellStatus Read only System State Temperature Status Details Name Object ID Description Syntax Access systemStateTemperatureStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 25 Defines the status of all temperature probes in this chassis T he first byte returned represents the status of the first temperature probe the second byte returned represents the status of the second temperature probe and so on Octet String Size 1 128 Read only 59 System State Group System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 26 Description Defines the state of all memory devices in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the state of the specific memory device T he first byte returned represents the state of the first memory device the second byte returned represents the status of the second memory device and so on T he bytes have the same definition type as DellStateSettings Syntax Octet String Size 1 128 Access Read only System State Memory Device Status Combined Name systemStateMemoryDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 27 Description Defines the status of all memory devices in this chassis Syntax DellStatus Access Read only System State Memory Device Status Details Name systemState
128. his M IB also contains information on RAC legacy alerting Table 1 7 describes each Dell RAC Out of Band group and lists the M IB group number assigned to the M IB group See the relevant section for more information about the M IB objects defined in aM IB group Table 1 7 Dell RAC Out of Band MIB Section Topics MIB Group Number 25 The Dell RAC Out of Band M IB consists of information for 2 the following groups Product Information on page 689 Chassis Status on page 693 Chassis Power on page 703 CMC Power Information on page 704 CMC PSU Information on page 708 Chassis Alerts on page 710 Legacy Alerting on page 712 How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide Table 1 8 Where to Find Definitions for Technical Terms Type of Definition See Basic SNM P vocabulary Introduction on page 17 M 1B group specific variable values Sections 3 5 7 8 9 and 11 M B group specific M IB variables contain links to the through 18 tables that define these values in the last section of the section in which these variables are used Systems management terms acronyms and Glossary available on the D ell commonly managed components referred to in this Support website at reference guide support dell com manuals 24 Introduction Table 1 8 Where to Find Definitions for Technical Terms
129. in configuration error state Configuration error type lt type of configuration error gt Power Supply Warning 1353 Power supply detected a warning Warning Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt Traps A power supply has been reconnected or replaced The sensor location chassis location previous state and additional information about the power supply event are provided A power supply sensor has detected a warning condition The sensor location chassis location previous state and additional power supply status information are provided Table 27 9 Power Supply Traps continued TrapID Description Severity Cause Power Supply Failure 1354 Power supply detected a failure Error A power supply has been Sensor location lt Location in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt disconnected or has failed The sensor location chassis location previous state
130. it is smaller than a megabyte Syntax Integer Access Read only Virtual Disk Length in Bytes Name virtualDiskLengthBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 7 Description Identifies the portion of the virtual disk in bytes that is smaller than a megabyte This size plus the virtualD iskL engthI nM B is the total size of the virtual disk Syntax Integer Access Read only Storage Management Group 659 Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 8 Description This entry is obsolete T his property is not supported by virtual disks managed under Storage M anagement Syntax Integer Access Read only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 9 Description This entry is obsolete T his property is not supported by virtual disks managed under Storage M anagement Syntax Integer Access Read only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 10 Description Indicates whether the controller s write cache are used when writing to a virtual disk Possible values 1 Enabled Adaptec W rite C ache Enabled Protected 2 Disabled Adaptec W rite C ache Disabled 3 LSI Write Back 4 LSI Write Through 5 Enabled Always Adaptec only 6 Enabled Always SAS only 9 Not Applicable Syntax Integer Access Read only 660 Stora
131. name used by this virtual disk s member disks Syntax DisplayString Access Read only Storage Management Group 657 Virtual Disk State Name virtualDiskState Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 4 Description Identifies the current state of this virtual disk Possible states 0 Unknown 1 Ready The disk is accessible and has no known problems 2 Failed The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 3 Online 4 Offline The disk is not accessible The disk may be corrupted or intermittently unavailable 6 Degraded The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 15 Resynching 16 Regenerating 24 Rebuilding 26 Formatting 32 Reconstructing 35 Initializing 36 Background Initialization 38 Resynching Paused 52 Permanently D egraded 54 Degraded Redundancy Syntax Integer Access Read only 658 Storage Management Group Virtual Disk Severity Name virtualDiskSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 5 Description T his entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 6 Description Identifies the size of this virtual disk in megabytes If this size is 0
132. nique See Table 12 2 Access Read write 222 Remote Flash BIOS Group Remote Flash BIOS Status Name Object ID Description Syntax Access remoteFlashBIOSStatus 1 3 6 1 4 1 674 10892 1 900 10 1 5 Defines the status of the remote BIOS update hardware on this system D ellRemoteF lashBIO SStateStatus Read only Remote Flash BIOS Last BIOS Date Name Name Object ID Description Syntax Access remoteFlashBIOSLastBIOSDateName 1 3 6 1 4 1 674 10892 1 900 10 1 6 Defines the date of the last BIOS update DellD ateN ame Read only Remote Flash BIOS Completion Code Name Object ID Description Syntax Access remoteFlashBIOSCompletionCode 1 3 6 1 4 1 674 10892 1 900 10 1 7 Defines the completion code of the last BIOS update DellRemoteF lashBI O SC ompletionC ode See Table 12 3 on page 225 Read only Remote Flash BIOS Minimum Contiguous Memory Name Object ID Description Syntax Access remoteFlashBIOSMinimumContiguousMemory 1 3 6 1 4 1 674 10892 1 900 10 1 8 Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes D ellU nsigned32BitR ange Read only Remote Flash BIOS Group 223 Remote Flash BIOS Variable Values This section includes definitions for server administrator specific variable values used in this section Table 12 1 Remote Flash BIOS State Capabilities Unique Variable Name De 1 1RemoteFlashBlOSStateCapabilitiesUnique Data T
133. nth fan to keep the chassis components at a safe temperature when the primary fan has failed Redundancy is normal when the intended number of critical components are operating Redundancy is degraded when a component fails but others are still operating Redundancy is lost when the number of components functioning falls below the redundancy threshold The number of devices required for full redundancy is provided as part of the trap message when applicable for the redundancy unit and the platform For more details on redundancy computation please refer to the respective platform documentation Table 27 8 Redundancy Unit Traps TrapID Description Severity Cause Redundancy Normal 1304 Redundancy regained Information A redundancy sensor in the specified system detected that a lost redundancy device has been reconnected Redundancy unit lt R edundancy location in chassis gt Chassis location lt N ame of or replaced full redundancy chassis gt isin effect The redundancy Previous redundancy state was unit location chassis lt State gt location and previous Number of devices required for redundancy statgare provided full redundancy lt N umber gt 708 l Traps Table 27 8 Redundancy Unit Traps continued TrapID Description Severity Cause Redundancy Degraded 1305 Redundancy degraded Warning A redundancy sensor in the Redundancy unit lt R edundancy specified system detected location in chassis gt
134. number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in aMIB group Table 1 4 Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group provides information about 2000 field replaceable units that may be present in your system Server Administrator Storage Management MIB The Server Administrator Storage M anagement M IB filename dcstorag mib provides storage management data that allows you to monitor the health of storage resources with SNM P management applications Table 1 5 describes each Server Administrator Storage M anagement M IB group and lists the M IB group number assigned to the M IB group T he Server Administrator Storage M anagement M IB groups are identified by the SNM P OID 1 3 6 1 4 1 674 lt M IB group number gt where lt MIB group number gt is the MIB group number assigned to the M IB group See the relevant section for more information about the M IB objects defined in a M IB group 22 Introduction Table 1 5 Server Administrator Storage Management MIB Sections in This Guide Section Topics MIB Group Numbers 23 Storage M anagement Group consists of definitions for the 10893 following M IB groups Storage Management Group e Storage Management Information Group e Global Data Group e Physical Devices Group e Logical Dev
135. objects in the storage hierarchy For example the status of a lower level object are propagated up to the status displayed on the Health tab for the top level storage object e Logs an alert into the Alert log and Microsoft W indows application log Sends an Simple Network M anagement Protocol SNM P trap if the operating system s SNM P service is installed and enabled K NOTE Storage M anagement does not log alerts regarding the data I O path These alerts are logged by the respective RAID drivers in the system alert log Storage M anagement Alert Reference 733 Viewing Alerts Storage M anagement generates alerts that are added to the W indows application alert log and to the Server Administrator Alert log To view these alerts in Server Administrator 1 Select the System object in the tree view 2 Select the Logs tab 3 Select the Alert subtab You can also view these alerts in the W indows E vent Viewer Every alert consists of the following e Severity Shows the severity of alert Date and Time Date and time when Storage M anagement logged the alert e Description A brief description of the alert To expand or collapse the alert description click the D escription column heading Alert Severity Levels Each alert message in the Storage M anagement alert log has a severity level which indicates the nature of the alert and is displayed in the Severity field of the alert message T he severity lev
136. of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned represents the state of the second cooling unit and so on The bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only 57 System State Group System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 20 Description Defines the state of all cooling devices in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling device The first byte returned represents the state of the first cooling device the second byte returned represents the state of the second cooling device and so on The bytes have the same definition type as D ellStateSettings Syntax Octet String Size 1 128 Access Read only System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 21 Description This attribute defines the cooling device status of all cooling devices in this chassis The results is returned as a combined status value The value has the same definition type as D ellStatus Syntax DellStatus Access Read only System State Cooling Device Status Details Name systemStateCoolingDeviceStatusDetails Object ID 1 3 6 1 4
137. only BIOS Setup Control Speaker Control Settings Unique Name bSUCspeakerControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 15 Description Defines the settings available for speaker control 393 BIOS Setup Control Group Name bSUCspeakerControlSettingsUnique Syntax DellSpeakerC ontrolSettingsU nique See Table 17 2 Access Read only BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 16 Description Defines the status of speaker control Syntax DellStatus Access Read only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 17 Description Defines the setup BIOS name of the speaker control Syntax DellString Access Read only BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique Name bSUCnIFwakeonLanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 18 Description Defines the defines the capabilities of the network interface function NIF Wakeup on LAN Syntax D ellN IF wakeonLanC ontrolC apabilitiesU nique See Table 17 4 Access Read only BIOS Setup Control NIF Wakeup on LAN Control Settings Unique Name bSUCnIFwakeonLanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 19 394 BIOS Setup Control Group Name Description Syntax Access bSUCnIFwakeonLanControlSettingsUnique Defines the state of the NIF Wakeup on LAN Del
138. or integrated NIF Table 17 5 Boot Sequence Control Capabilities Unique Variable Name De 1 1Boot SequenceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value boot SequenceUnknown 1 Boot sequence capabilities are unknown bootFromDisketteFirstCapable Setup BIOS can boot from a diskette 2 first bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard 4 drive first bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or FirstCapable 6 an IDE hard drive first 420 BIOS Setup Control Group Table 17 5 Boot Sequence Control Capabilities Unique continued Variable Name De 1 1Boot SequenceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value bootFromDeviceListCapable 8 Setup BIOS can boot from a device list bootFromCDROMFirstCapable 16 Setup BIOS can boot from aCD first allFirstCapable 30 Setup BIOS can boot by any of the preceding methods first Table 17 6 Boot Sequence Control Settings Unique Variable Name De 1 1Boot SequenceControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value boot SequenceUnknown 1 Boot sequence state is unknown bootFromDisketteFirst 2 Setup BIOS is set to boot by diskette first bootFromHardDriveFirst 4 Setup BIOS is set to boot by ID E hard drive first bootFromDeviceList 8
139. ports in this chassis Syntax DellO bjectRange Access Read only 242 Port Group SCSI Port State Capabilities Name Object ID Description Syntax Access sCSIPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 60 1 3 Defines the capabilities of the SCSI port D ellStateC apabilities Read only SCSI Port State Settings Name DellStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 4 Description Defines the state and settings of the SCSI port Syntax DellStatus Access Read write SCSI Port Status Name sCSIPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 5 Description Defines the status of the SCSI port Syntax DellStatus Access Read only SCSI Port Security State Name sCSIPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 6 Description Defines the security settings of the SC SI port Syntax D ellPortSecurityState Access Read only PortGroup 243 SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 7 Description Defines the connector type of the SCSI port Syntax DellSC SI PortC onnectorType See Table 13 6 Access Read only SCSI Port Name Name sCSIPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 8 Description Defines the name of the SCSI port Syntax DellString Access Read only SCSI Port BIOS Connector Type Name sCSIPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 9 Description Defines the BIOS connector typ
140. rate of the BMC serial interface Syntax DellBM C SerialBitRateType Access Read only 538 Baseboard M anagement Controller Group Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 30 Description Defines the Baseboard M anagement Controller BMC LAN Interface Table Syntax SEQUENCE OF BmcLANInterfaceTableE ntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 Description Defines the Baseboard M anagement Controller BMC LAN Interface Table Entry Syntax BmcLAN InterfaceTableE ntry Access Not accessible Index bmcLAN InterfaceC hassisl ndex bmcLAN InterfaceBM C Index bmcLANInterfacel ndex BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 1 Description Defines the index one based of the associated chassis Syntax DellO bjectRange Access Read only 539 Baseboard Management Controller Group BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 2 Description Defines the index one based of the associated BMC Syntax DellO bjectRange Access Read only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 3 Description Defines the index one based of the BMC LAN interface Syntax DellO bjectRange Access R
141. re seller s name DisplayString Read only Enclosure State Name Object ID Description Syntax Access enclosureState 1 3 6 1 4 1 674 10893 1 20 130 3 1 4 The current condition of the enclosure which includes any devices connected to it Possible values 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Integer Read only Storage Management Group 589 590 Enclosure Severity Name Object ID Description Syntax Access Enclosure ID Name Object ID Description Syntax Access enclosureSeverity 1 3 6 1 4 1 674 10893 1 20 130 3 1 5 This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Integer Read only enclosureID 1 3 6 1 4 1 674 10893 1 20 130 3 1 6 Identifies the SC SI address of the processor Integer Read only Enclosure Processor Version Name Object ID Description Syntax Access enclosureProcessorVersion 1 3 6 1 4 1 674 10893 1 20 130 3 1 7 This entry is obsolete for Storage M anagement DisplayString Read only Enclosure Service Tag Name Object ID Description Syntax Access enclosureServiceTag 1 3 6 1 4 1 674 10893 1 20 130 3 1 8 The enclosure identification used when consulting customer support DisplayString Read only Storage Management Group Enclosure Asset Tag Name Object ID Description Syntax Access enclosureAssetTag 1 3 6 1 4 1 674 10893 1 2
142. remoteDialUpIsOther 1 The remote dial type is not one of the following remoteDialUpIsUnknown 2 The remote dial type is unknown remoteDialUpIsTone 3 The remote dial type is tone remoteDialUpIsPulse 4 The remote dial type is pulse 522 Remote Access Group Table 20 25 Remote User Dial In State Capabilities Variable Name De 1 1RemoteUserDialInStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial in user has no state capabilities unknownCapabilities 1 The dial in user state capabilities are unknown enableCapable 2 The dial in user can be disabled or enabled notReadyCapable 4 The dial in user can be in the not ready state dialInCallbackPresetNumber Capable 8 The dial in user can support callback using a preset number dialInCallbackUserSpecified The dial in user can support callback Capable 16 using a user specified number Table 20 26 Remote User Dial In State Settings Variable Name De 1 1RemoteUserDialInStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial in user has no state settings unknown 1 The dial in user state settings are unknown enabled 2 The dial in user is enabled notReady 4 The dial in user is in the not ready state dialInCallbackPresetNumber Enabled 8 Callback usi
143. returned for this attribute is the power usage that the probe is reading in tenths of Amperes W hen the value for amperageProbeType is amperageProbeT ypel sPowerSupplyW atts or amperageProbeTypel sSystemW atts the value returned for this attribute is the power usage that the probe is reading in Watts W hen the value for amperageProbeType is other than amperageProbeTypel sD iscrete amperageP robeT ypel sPowerSupplyAmps amperageProbeT ypel sPowerSupplyW atts amperageProbeT ypel sSystemAmps or amperageProbeTypel sSystemW atts the value returned for this attribute is the amperage that the probe is reading in M illiamps W hen the value for amperageProbeType is amperageProbeTypel sD iscrete a value is not returned for this attribute DellSigned32BitRange Read only Power Group 165 Amperage Probe Type Name Object ID Description Syntax Access amperageProbeTyp 1 3 6 1 4 1 674 10892 1 600 30 1 7 Defines the type of the amperage probe DellAmperageProbeType Read only Amperage Probe Location Name Name Object ID Description Syntax Access amperageProbeLocationName 1 3 6 1 4 1 674 10892 1 600 30 1 8 Defines the location name of the amperage probe in this chassis DellString Read only Amperage Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax Access amperageProbeUpperNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 9 Defines the value of the amperag
144. sensor reading is System Voltage Informational within range Health Voltage Probe Warning 2170 Voltage sensor has System Voltage M inor detected a warning value Health Voltage Probe Failure 2169 Voltage sensor has System Voltage Critical detected a failure value Health iDRAC7 MIB Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category of iD RAC 7 Storage traps are traps generated in response to events related to the external storage subsystem of the system in which iD RAC 7 resides iDRAC7MIB 761 Table 29 27 Battery Traps TrapID Description Category SubCategory Severity Battery Normal 4275 Battery state has Storage Battery Event Informational returned to normal or battery presence has been detected Battery Warning 4274 Battery is low Storage Battery Event M inor Battery Failure 4273 Battery has failed or Storage Battery Event Critical battery is absent Table 29 28 Controller Traps TrapID Description Category SubCategory Severity Storage Controller Information 4331 Controller information Storage Storage Informational Contr Storage Controller Warning 4330 Controller warning Storage Storage M inor Contr Storage Controller Failure 4329 Controller failure Storage Storage Critical Contr Table 29 29 Enclosure Traps TrapID Description Category SubCategory Severity Storage Enclosure Information 4339 Enclosure information
145. supply fails the corresponding entry in system StatePowerSupplyStatusD etails system StatePowerSupplyStatusC ombined systemStateC hassisStatus and system StateG lobal SystemStatus transitions to critical System State Group 49 List 1 Variables that provide rolled up health status for all components in associated subsystem in chassis e systemStatePowerSupplyStatusC ombined e systemStateVoltageStatusC ombined e systemStateAmperageStatusC ombined e systemStateC oolingD eviceStatusC ombined e systemStateT emperatureStatusC ombined e systemStateM emoryD eviceStatusC ombined e systemStateC hassisl ntrusionStatusC ombined systemStateAC PowerC ordStatusC ombined e systemStateE ventL ogStatus e systemStatePowerU nitStatusC ombined e systemStateC oolingU nitStatusC ombined e systemStateAC PowerSwitchStatusC ombined systemStateR edundantM emoryU nitStatusC ombined e systemStateProcessorD eviceStatusC ombined e systemStateBatteryStatusC ombined e systemStateSD C ardU nitStatusC ombined e systemStateSD C ardD eviceStatusC ombined List 2 Variables that provide health status of each component in associated subsystem in chassis e systemStatePowerSupplyStatusD etails e systemStateVoltageStatusD etails e systemStateAmperageStatusD etails e systemStateC oolingD eviceStatusD etails e systemStateT emperatureStatusD etails e system
146. system resource DMA D ellResourceShareD isposition See Table 8 3 Read only System Resource DMA Maximum Transfer Size Name Object ID Description Syntax Access systemResourceDMAMaximumTransferSize 1 3 6 1 4 1 674 10892 1 500 60 1 8 Defines the maximum size of a memory transfer in bytes for the system resource DMA DellU nsigned32BitRange Read only System Resource DMA Transfer Width Name Object ID Description Syntax Access systemResourceDMATransferWidth 1 3 6 1 4 1 674 10892 1 500 60 1 9 Defines the transfer width of the system resource DM A DellResourceD M ATransferW idth See Table 8 8 Read only System Resource Group 145 System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 10 Description Defines the bus mastering capabilities of the system resource DM A Syntax D ellResourceD M ABusM aster See Table 8 7 Access Read only System Resource Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 8 1 System Resource Map Type Variable Name De11SystemResourceMapType Data Type Integer Possible Data Values Meaning of Data Value other 1 The system resource map type is not one of the following unknown 2 The system resource map type is unknown not known or not monitored typeOne 3 The system resource map is type 1 one Ta
147. systems Name Object ID Description Syntax Access biosSettingTable 1 3 6 1 4 1 674 10892 1 1400 90 Defines the BIOS Setting Table SEQUENCE OF BiosSettingTableE ntry Not accessible BIOS Setting Table Entry Name Object ID Description Syntax Access Index biosSettingTableEntry 1 3 6 1 4 1 674 10892 1 1400 90 1 Defines the BIOS Setting Table Entry BiosSettingTableE ntry Not accessible biosSettingC hassis ndex biosSettingl ndex BIOS Setting Chassis Index Name Object ID Description Syntax Access biosSettingChassisIndex 1 3 6 1 4 1 674 10892 1 1400 90 1 1 Defines the index one based of the associated chassis DellObjectRange Read only BIOS Setting Index Object ID biosSettingIndex 1 3 6 1 4 1 674 10892 1 1400 90 1 2 BIOS Setup Control Group 415 Description Defines the index one based of the BIOS setting Syntax DellObjectRange Access Read only BIOS Setting Name Name biosSettingName Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 3 Description Defines the name of the BIOS setting Syntax DisplayString Access Read only BIOS Setting Display Name Name biosSettingDisplayName Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 4 Description Defines the display name of the BIOS setting Syntax DisplayString Access Read only BIOS Setting Value Type Name biosSettingValueType Object ID 1 3 6 1 4 1 674 10892 1 1400 90 1 5 Description Defines the type of the BIOS setting value Syntax
148. the data collection started for the value reported by the powerU sagePeakAmps attribute Syntax DellDateName Access Read only Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 14 Description Defines the date and time at which the value reported by the powerU sagePeakA mps attribute was measured Syntax DellDateName Access Read only Power Usage Idle Power Name powerUsagelIdlePower Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 15 Description Defines the system idle power in Watts This is the minimum power the system can consume based on the current hardware configuration Syntax DellUnsigned32BitRange Access Read only Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 16 180 Power Group Description Syntax Access powerUsageMaxPotentialPower Defines the maximum potential power in Watts of the system This is the maximum power the system can consume based on the current hardware configuration DellU nsigned32BitRange Read only Power Usage Power Cap Capabilities Name Object ID Description Syntax Access powerUsagePowerCapCapabilities 1 3 6 1 4 1 674 10892 1 600 60 1 17 Defines the system power cap capabilities DellPowerC apC apabilities Read only Power Usage Power Cap Setting Name Object ID Description Syntax Access powerUsagePowerCapSe
149. the parallel port in this chassis DellO bjectRange Read only Parallel Port Control Capabilities Unique Name Object ID Description Syntax Access parallelPortControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 3 Defines the capabilities of the parallel port DellParallelPortC ontrolC apabilitiesU nique See Table 17 12 Read only Parallel Port Control Settings Unique Name Object ID Description Syntax Access parallelPortControlSettingsUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 4 Defines the state of the parallel port DellParallelPortC ontrolSettingsU nique See Table 17 13 Read only Parallel Port Control Status Name Object ID Description Syntax Access parallelPortControlStatus 1 3 6 1 4 1 674 10892 1 1400 30 1 5 Defines the status of the parallel port DellStatus Read only BIOS Setup Control Group 403 Parallel Port Control Name Name parallelPortControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 6 Description Defines the setup BIOS name of the parallel port Syntax DellString Access Read only Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 7 Description Defines the mode capabilities of the parallel port Syntax DellParallelPortC ontrolM odeC apabilitiesU nique See Table 17 14 Access Read only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUniqu
150. the system powers off This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time Automatic System Recovery 1006 Automatic System Error Recovery ASR action was performed Action performed was lt Action gt Date and time of action lt Date and time gt This message is generated when an automatic system recovery action is performed due to a hung operating system T he action performed and the date and time of the action are provided Traps 697 Table 27 2 Miscellaneous Traps continued TrapID Description Severity Cause Host System Reset 1007 User initiated host system Information User requested a host system control action control action to reboot power off Action requested was or power cycle the system or lt Action gt another event such as thermal shutdown protection initiated a power off operating system shutdown System Peak Power New Peak 1013 System Peak Power Information This message is generated when the detected new peak value system peak power sensor has Peak value in Watts detected a new peak value lt Reading gt System Software Event 1014 System software event has M inor This message is generated when a occured system software event occurs The description of the event and the date and time of the event are provided Description lt Description of event gt Date and time of action
151. the system resource 1 0 port DellStateSettings Read write System Resource Group 135 System Resource 1 0 Port Status Name systemResourcelOPortStatus Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 5 Description Defines the status of the system resource I O port Syntax D ellStateSettings Access Read only System Resource 1 0 Port Owner Index Reference Name systemResourcelOPortOwnerIndexReferenc Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 6 Description Defines the index to the associated system resource owner in this chassis Syntax DellO bjectRange Access Read only System Resource I O Port Share Disposition Name systemResourcelOPortShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 7 Description Defines the share disposition of the system resource I O port Syntax D ellResourceShareD isposition See Table 8 3 Access Read only System Resource 1 0 Port Starting Address Name systemResourcelOPortStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 8 Description Defines the 64 bits of the starting address of the system resource 1 0 port Syntax D ellU nsigned64BitRange Access Read only 136 l System Resource Group System Resource I O Port Ending Address Name Object ID Description Syntax Access systemResourcelOPortEndingAddress 1 3 6 1 4 1 674 10892 1 500 30 1 9 Defines the 64 bits of the ending address of the system resource 1 0 port DellU nsigned64BitRange Read only
152. warranty for a particular system Name cooWarrantyTable Object ID 1 3 6 1 4 1 674 10892 1 1600 40 Description Defines the COO Warranty Table Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 Description Defines the COO Warranty Table entry Syntax C ooWarrantyTableE ntry Access Not accessible Index cooW arrantychassis ndex cooW arrantyl ndex COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read write COO Warranty Index Name cooWarrantyIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 2 Description Defines the index of the warranty for this system Syntax DellO bjectRange Access Read only 452 Cost of Ownership Group COO Warranty State Name cooWarrantyState Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 3 Description Defines the state of the warranty for this system Syntax DellStateSettings Access Read only COO Warranty Duration Name cooWarrantyDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 4 Description Defines the duration of the warranty Syntax DellUnsigned32BitRange Access Read write COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 5 Description Defines the warranty duration type for th
153. 0 130 3 1 9 Customer definable asset tag for the enclosure DisplayString Read only Enclosure Asset Name Name Object ID Description Syntax Access enclosureAssetName 1 3 6 1 4 1 674 10893 1 20 130 3 1 10 Customer definable asset name of the enclosure DisplayString Read only Enclosure Split Bus Part Number Name Object ID Description Syntax Access enclosureSplitBusPartNumber 1 3 6 1 4 1 674 10893 1 20 130 3 1 11 Identifies the enclosure s split bus part number DisplayString Read only Enclosure Product ID Name Object ID Description Syntax Access enclosureProductID 1 3 6 1 4 1 674 10893 1 20 130 3 1 12 Identifies the enclosure s product identification This also corresponds to the enclosure type DisplayString Read only Storage Management Group 591 Enclosure Kernel Version Name enclosureKernelVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 13 Description This entry is obsolete for Storage M anagement Syntax DisplayString Access Read only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 14 Description T his entry is obsolete for Storage Management Syntax DisplayString Access Read only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 15 Description This entry is obsolete for Storage M anagement Syntax DisplayString Access Read only 592 Storage Ma
154. 000 10 6 Provides Server Administrator defined data related to the alert Octet String SIZE 0 1024 Understanding the Trap Description Table 27 1 listsin alphabetical order each line item that may appear in the trap description Table 27 1 Trap Description Reference Description Line Item Explanation Action performed was lt Action gt Specifies the automatic server recovery action that was performed for example Action performed was Power cycle Traps 691 692 Table 27 1 Trap Description Reference continued Description Line Item Explanation Action requested was lt Action gt Specifies the user initiated host control action that was requested for example Action requested was Reboot shutdown OS first Additional details lt Additional details for the events gt Specifies possible additional details about the specified device for example Additional details Memory device DIMM_1A Serial number 11111111 Memory device DIMM_1B Serial number 22222222 lt Additional power supply status information gt Specifies any additional power supply information pertaining to the event for example Power supply input AC is off Power supply POK power OK signal is not normal Power supply is turned off Battery sensor status lt status gt Specifies the status reported by the battery sensor for example Battery sensor status
155. 0892 1 1500 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only LRA Global State Name 1RAGlobalState Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 2 Description Defines the state of the LRA global settings Syntax DellStateSettings Access Read only 430 Local Response Agent Group LRA Global Settings Disable Time out Value Name Object ID Description Syntax Access 1RAGlobalSettingsDisableTimeoutValue 1 3 6 1 4 1 674 10892 1 1500 10 1 3 Defines the time out duration countdown in seconds that the LRA global settings are disabled after a system shutdown and reboot DellU nsigned32BitRange Read only LRA Global Settings Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalSettingsCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 4 Defines the set of global capabilities that all local response agents may or may not allow to be set or reset DellLocalResponseA gentC apabilitiesU nique See Table 18 1 Read only LRA Global Thermal Shutdown Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalThermalShutdownCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 5 Defines the set of thermal shutdown capabilities that are supported by the LRA DellLRAT hermalShutdownC apabilitiesU nique Read only LRA Global Thermal Shutdown State Settings Unique Name Object ID Description Syntax Acc
156. 1 1600 30 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 2 Description Defines the index one based of the cost event log Syntax DellO bjectRange Access Read only 450 Cost of Ownership Group COO Cost Event Log State Name Object ID Description Syntax Access cooCostEventLogState 1 3 6 1 4 1 674 10892 1 1600 30 1 3 Defines the cost event log state of this system DellStateSettings Read only COO Cost Event Log Duration Name Object ID Description Syntax Access cooCostEventLogDuration 1 3 6 1 4 1 674 10892 1 1600 30 1 4 Defines the duration of the event for this system DellU nsigned32BitRange Read write COO Cost Event Log Duration Type Name Object ID Description Syntax Access cooCostEventLogDurationType 1 3 6 1 4 1 674 10892 1 1600 30 1 5 Defines the duration type of the event for this system DellC OOH ourD ayD urationType See Table 19 2 Read write COO Cost Event Log Description Name Name Object ID Description Syntax Access cooCostEventLogDescriptionName 1 3 6 1 4 1 674 10892 1 1600 30 1 6 Defines the name of the event description DellC ostofO wnershipString Read write Costof Ownership Group 451 COO Warranty Table TheCOO Warranty Table objects enable you to track facts about the type and duration of the
157. 1 3 6 1 4 1 674 10892 1 1400 60 1 Defines the IDE Control Table entry IdeC ontrolTableE ntry Not accessible ideC ontrolchassisl ndex ideC ontroll ndex IDE Control Chassis Index Name Object ID Description Syntax Access IDE Control Index Name Object ID Description Syntax Access ideControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 60 1 1 Defines the index one based of this chassis DellO bjectRange Read only ideControliIndex 1 3 6 1 4 1 674 10892 1 1400 60 1 2 Defines the index one based of the IDE controller in this chassis DellO bjectRange Read only IDE Control Capabilities Unique Name Object ID Description Syntax Access ideControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 60 1 3 Defines the capabilities of the IDE controller DellideC ontrolC apabilitiesU nique See Table 17 17 Read only BIOS Setup Control Group 409 IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 4 Description Defines the settings for the IDE controller Syntax DellideC ontrolC apabilitiesU nique See Table 17 17 Access Read only IDE Control Status Name ideControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 5 Description Defines the status for the IDE controller Syntax DellStatus Access Read only IDE Control Name Name ideControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 6 Description Defines the setup BIOS name for the IDE
158. 1 3 6 1 4 1 674 10892 1 1700 20 1 8 Description Defines the password for this remote access user Syntax DisplayString SIZE 0 255 Access Read write Remote Access Group 489 Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 9 Description Defines the privileges for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin User Privilege Capabilities Name remot eUserAdminUserPrivilegeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 10 Description Defines the privilege capabilities for this remote access user Syntax DisplayString SIZE 0 31 Access Read only Remote User Admin Alert Filter DRS Events Mask Name remoteUserAdminAlertFilterDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 11 Description Defines the DRS events filter mask for this remote access user Syntax DellU nsigned32BitRange Access Read write Remote User Admin Alert Filter System Events Mask Name remoteUserAdminAlertFilterSysEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 12 Description Defines the system events filter mask for this remote access user Syntax DellU nsigned32BitRange Access Read write 490 Remote Access Group Remote User Admin Alert Filter DRS Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterDrsCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 13 Def
159. 1 3 6 1 4 1 674 10892 1 300 10 1 30 1 1 798 SNMP Sample Output L 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 3 6 1 4 1 674 10892 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 Lads Oel y4e1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 cleared 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 1 1 3 6 1 4 1 674 10892 20050513100047 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 300 300 300 300 300 300 300 000000 360 O O e G O O a G Oe Oe Oe O Oe Ga Tesisi L32 L 1 33 1 1 34 1 Teso L 1 36 1 132s L MS gul ei n 1 44 1 1 45 1 15 27 480 Oo OC N NY FF SNMP Sample Output 799 800 SNMP Sample Output Index Numerics 1403 731 1404 732 1602 736 1603 736 737 1604 737 1651 738 1653 738 A Application 676 Application Group 676 BIOS Group BIOS Setup Control Table 389 Diskette C ontrol Table 410 IDE Control Table 408 Network Interface C ontrol Table 412 Parallel Port C ontrol Table 402 SCSI Control Table 400 Serial Port Control Table 404 USB Control Table 406 BIOS Group tables 389 BIOS Setup Control Group 389 variable values 418 C Change 673
160. 1 4 1 674 10892 1 1400 10 1 39 Description Defines the BIOS setup control name of Trusted Platform Module TPM security Syntax DellString Access Read only SCSI Control Table Name sCSIControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 20 Description Defines the Small Computer System Interface SC SI Control Table Syntax SCSIC ontrolTableE ntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 Description Defines the SCSI Control Table entry Syntax SCSIC ontrolTableE ntry Access Not accessible Index sC SIC ontrolchassisl ndex sC SIC ontroll ndex SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only 400 BIOS Setup Control Group SCSI Control Index Name Object ID Description Syntax Access sCSIControlindex 1 3 6 1 4 1 674 10892 1 1400 20 1 2 Defines the index one based of the SC SI controller in this chassis DellO bjectRange Read only SCSI Control Capabilities Name Object ID Description Syntax Access sCSIControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 20 1 3 Defines the capabilities of the SCSI controller DellStateC apabilities Read only SCSI Control Settings Name Object ID Description Syntax Access sCSIControlSettings 1 3 6 1 4 1 674 10892 1 1400
161. 1 674 10892 1 1600 110 Description Defines the COO Trouble Ticket Table Syntax SEQUENCE OF cooTroubleT icketTableE ntry Access Not accessible 466 Cost of Ownership Group COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 Description Defines the COO Trouble Ticket Table entry Syntax cooTroubleT icketTableE ntry Access Not accessible Index cooTroubleT icketchassislndex cooTroubleT icketl ndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Trouble Ticket Index Name cooTroubleTicket Index Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 2 Description Defines the index one based of the system s trouble ticket information Syntax DellObjectRange Access Read only COO Trouble Ticket State Name cooTroubleTicketState Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 3 Description Defines the trouble ticket information state for this system Syntax DellStateSettings Access Read only CostofOwnership Group 467 COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 4 Description Defines the support information index that references the trouble ticket Syntax D ellU nsigned32BitR ange A
162. 1 674 10892 1 200 10 1 22 Description Defines the status of all cooling devices in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the status of a specific cooling device The first byte returned represents the status of the first cooling device the second byte returned represents the status of the second cooling device and so on The bytes have the same definition type as D ellStatus Syntax Octet String Size 1 128 Access Read only 58 System State Group System State Temperature State Details Name Object ID Description Syntax Access systemStateTemperatureStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 23 Defines the state of all temperature probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific temperature probe The first byte returned represents the state of the first temperature probe the second byte returned represents the status of the second temperature probe and so on The bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only System State Temperature Status Combined Name Object ID Description Syntax Access systemStateTemperatureStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 24 Defines the status of all temperature probes in this chassis The result is returned as a combined status value T he value
163. 1 674 10893 1 20 130 4 1 15 Description Identifies the SCSI target ID which this array disk is assigned Syntax Integer Access Read only Array Disk LUN ID Name arrayDiskLunID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 16 Description Identifies the array disk s logical unit number Syntax Integer Access Read only 604 Storage Management Group Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 17 Description Identifies the amount in megabytes of the used space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte This size plus the arrayD iskU sedSpacel nM B is the total amount of used space on the array disk Syntax Integer Access Read only Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 19 Description Identifies the amount in megabytes of the free space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Storage Management Group 605 Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 20 Description Identifies the
164. 1 9 Description Defines the callback phone number for this remote access dial in user Syntax DisplayString SIZE 0 95 Access Read write Remote Dial Out Table Name remoteDialOutTable Object ID 1 3 6 1 4 1 674 10892 1 1700 60 Description Defines the Remote Access Dial Out Table Syntax SEQUENCE of RemoteDialOutTableE ntry Access Not accessible Remote Dial Out Table Entry Name remoteDialOutTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 Description Defines the Remote Access Dial Out Table entry Syntax RemoteD ialO utTableE ntry Access Not accessible Index remoteD ialO utC hassisI ndex remoteD ialO utAdapter ndex remoteD ialO utD ialO utIndex Remote Dial Out Chassis Index Name remoteDialOutChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellO bjectRange Access Read only Remote Access Group 507 Remote Dial Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial out functionality Syntax DellObjectRange Access Read only Remote Dial Out Dial Out Index Name remoteDialOutDialOutIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 3 Description Defines the index one based of this remote access dial out functionality Syntax De
165. 10 Description Defines the status of all power supplies in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power supply The first byte returned represents the status of the first power supply the second byte returned represents the status of the second power supply and so on The bytes have the same definition type as D ellStatus Syntax Octet String Size 1 128 Access Read only 54 System State Group System State Voltage State Details Name Object ID Description Syntax Access systemStateVoltageStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 11 Defines the state of all voltage probes in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the status of a specific voltage probe The first byte returned represents the status of the first voltage probe the second byte returned represents the status of the second voltage probe and so on The bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only System State Voltage Status Combined Name Object ID Description Syntax Access systemStateVoltageStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 12 Defines the status of all voltage probes in this chassis DellStatus Read only System State Voltage Status Details Name Object ID Description Syntax Access systemStateVolt
166. 1100 70 1 7 Defines the type of the generic device DellGenericD eviceType See Table 14 18 Read only 296 Device Group Generic Device Name Name genericDeviceNam Object ID 1 3 6 1 4 1 674 10892 1 1100 70 1 8 Description Defines the name of the generic device Syntax DellString Access Read only PCI Device Table Name pCIDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 80 Description Defines the PCI Device D etail Table Syntax SEQUENCE OF PCIDeviceTableE ntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 Description Defines the PCI D evice Table entry Syntax Not accessible Access PC DeviceTableE ntry Index pC ID evicechassisl ndex pC ID evicel ndex PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 1 Description Defines the index one based of this chassis Syntax Read only Access DellO bjectRange DeviceGroup 297 PCI Device Index Name pCIDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 2 Description Defines the index one based of the PCI device in this chassis Syntax DellObjectRange Access Read only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 3 Description Defines the capabilities of the PCI device Syntax DellStateC apabilities Access Read only PCI Device State Settings Name pCIDeviceStateSett
167. 16 The processor family is Xeon deviceFamilyIsPentium3 17 The processor family is Pentium III deviceFamilyIsPentium3Xeon 18 The processor family is Pentium III Xeon deviceFami lyIsPentium3Step 19 The processor family is Pentium IH Speed Step deviceFamilyIsPentiumItanium The processor family is Itanium 20 deviceFamilyIsIntelXeon 21 The processor family is Intel Xeon deviceFamilyIsPentium4 22 The processor family is Pentium 4 deviceFamilyIsIntelXeonMP 23 The processor family is Intel Xeon MP deviceFamilyIsIntelItanium2 24 The processor family is Intel Itanium 2 deviceFamilyIsK5 25 The processor family is K5 deviceFamilyIsk6 26 The processor family is K6 deviceFamilyIsK6 2 27 The processor family is K6 2 deviceFamilyIsk6 3 28 The processor family is K6 3 deviceFamilyIsAMDAthlon 29 The processor family is AM D Athlon deviceFamil LyIsAMD2900 30 The processor family is AM D 2900 Device Group 325 Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIskK6 2Plus 31 The processor family is K6 2 deviceFamilyIsPowerPC 32 The processor family is Power PC deviceFamilyIsPowerPC601 33 The processor family is Power PC 601 deviceFamilyIsPowerPC603 34 The processor family is Power PC 603 de
168. 17 12 Parallel Port Control Capabilities Variable Name De11ParallelPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enableCapable 2 Setup BIOS parallel port capabilities are unknown Setup BIOS can enable the parallel port lpt1lCapable 4 Setup BIOS can support parallel port 1 lptlandEnableCapable 6 Setup BIOS has enabled parallel port 1 lpt2Capable 8 Setup BIOS can support parallel port 2 lpt2andEnableCapable 10 Setup BIOS has enabled parallel port 2 lpt3Capable 16 Setup BIOS can support parallel port 3 lpt3andEnableCapable 18 Setup BIOS has enabled parallel port 3 allParallelPortCapable 30 Setup BIOS can support any of the three parallel ports Table 17 13 Parallel Port Control Settings Variable Name De11ParallelPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port state is unknown enabled 2 Setup BIOS has enabled the parallel port lptl 4 Setup BIOS supports parallel port 1 lpt 1Enabled 6 Setup BIOS has enabled parallel port 1 lpt2 8 Setup BIOS supports parallel port 2 lpt2Enabled 10 Setup BIOS has enabled parallel port 2 lpt3 16 Setup BIOS supports parallel port 3 424 BIOS Setup Control Group Table 17 14
169. 2 Description Defines an optional component ID field for the device Syntax Integer Access Read only Device Display String Name deviceDisplayString Object ID 1 3 6 1 4 1 674 10899 1 5 1 3 Description Provides a displayable string that describes the device Syntax DisplayString Access Read only Device Vendor ID Name deviceVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 4 Description Defines the D for the vendor supplying the device Syntax Octet String Access Read only Device ID Name deviceDeviceID Object ID 1 3 6 1 4 1 674 10899 1 5 1 5 Description Defines the ID for the device Syntax Octet String Access Read only ChangeManagementGroup 675 Device Sub ID Name deviceSubID Object ID 1 3 6 1 4 1 674 10899 1 5 1 6 Description Provides additional device identification Syntax Octet String Access Read only Device Sub Vendor ID Name deviceSubVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 7 Description Provides additional vendor identification Syntax Octet String Access Read only Application Group K NOTE Dell updateable components such as Basic input output system BIOS and FirmWare FW are considered applications For example the following would be returned for system BIOS Application DisplayString BIOS Application Version A10 The Application Group defines information about the applications discovered on the system during an inventory scan Identifying information includes the applicatio
170. 20 1 4 Defines the state of the SC SI controller DellStateSettings Read only SCSI Control Status Name Object ID Description Syntax Access sCSIControlStatus 1 3 6 1 4 1 674 10892 1 1400 20 1 5 Defines the status of the SCSI controller DellStatus Read only BIOS Setup Control Group 401 SCSI Control Name Name sCSIControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 6 Description Defines the setup BIOS name of the SCSI controller Syntax DellString Access Read only Parallel Port Control Table Name parallelPortControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 30 Description Defines the Parallel Port Control Table Syntax ParallelPortC ontrolTableE ntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 Description Defines the Parallel Port C ontrol Table entry Syntax ParallelPortC ontrolTableE ntry Access Not accessible Index parallelPortC ontrolchassisI ndex parallelPortC ontrollndex Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only 402 BIOS Setup Control Group Parallel Port Control Index Name Object ID Description Syntax Access parallelPortControliIndex 1 3 6 1 4 1 674 10892 1 1400 30 1 2 Defines the index one based of
171. 20 130 4 1 2 Description Identifies the name of the array disk as represented in Storage Management Syntax DisplayString Access Read only Array Disk Vendor Name arrayDiskVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 3 Description The array disk s manufacturer s name Syntax DisplayString Access Read only 600 Storage Management Group Array Disk State Name Object ID Description Syntax Access arrayDiskState 1 3 6 1 4 1 674 10893 1 20 130 4 1 4 Identifies the current state of the array disk Possible states 0 Unknown 1 Ready Available for use but no RAID configuration has been assigned 2 Failed Not operational 3 Online Operational RAID configuration has been assigned 4 Offline The drive is not available to the RAID controller 6 Degraded Refers to a fault tolerant array virtual disk that has a failed disk 7 Recovering Refers to state of recovering from bad blocks on disks 11 Removed Indicates that array disk has been removed 15 Resynching Indicates one of the following types of disk operations Transform Type Reconfiguration and C heck Consistency 24 Rebuild 25 No Media CD ROM or removable disk has no media 26 Formatting In the process of formatting 28 Diagnostics Diagnostics are running 34 Predictive Failure 35 Initializing Applies only to virtual disks on PERC PERC 2 SC and PERC 2 DC controllers 39 Foreign 40 Clear 41 Un
172. 300 1 T2 2s lo OV1s23 gt 1 lt 0 1 24 1 3 OV1 25el 0 1 26 1 Osle tetin 3 Oeil 28331 0 1 29 1 N02 0 1 30 1 3 Od Slal VYT 0 1 41 1 3 0 1 42 1 3 0 1 43 1 03 Oke dT sed Owl eZ 0 O 1 321 2 0 1 4 1 3 0 1 5 1 0 UTG 23 0 1 7 1 Main System 0 1 8 1 Dell Inc SNMP Sample Output 797 1 3 6 1 4 1 674 10892 1 300 10 1 9 1 PowerEdge 2650 1 3 6 1 4 1 674 10892 1 300 10 1 10 1 ASSETTAG 1 3 6 1 4 1 674 10892 1 300 10 1 11 1 1234567 1 3 6 1 4 1 674 10892 1 300 10 1 12 1 254 1 3 6 1 4 1 674 10892 1 300 10 1 13 1 289 1 3 6 1 4 1 674 10892 1 300 10 1 14 1 4 1 3 6 1 4 1 674 10892 1 300 10 1 15 1 SERVEROL 1 3 6 1 4 1 674 10892 1 300 10 1 16 1 20050513095213 000000 360 1 3 6 1 4 1 674 10892 1 300 10 1 17 1 20050513100052 000000 360 1 3 6 1 4 1 674 10892 1 300 10 1 18 1 Please set the value 1 3 6 1 4 1 674 10892 1 300 10 1 19 1 Please set the value 1 3 6 1 4 1 674 10892 1 300 10 1 20 1 Please set the value 1 3 6 1 4 1 674 10892 1 300 10 1 21 1 3 1 3 6 1 4 1 674 10892 1 300 10 1 22 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 23 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 24 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 25 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 26 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 27 1 0 1 3 6 1 4 1 674 10892 1 300 10 1 28 1 8 1 3 6 1 4 1 674 10892 1 300 10 1 29 1 2
173. 41 Management Information Base Major Version Number 41 Management Information Base Minor Version Number 42 Management Information Base Maintenance Version Number 42 Systems Management Software Group 43 Systems Management Software 43 Systems Management Software Variable Values 47 System State Group 49 System State Group Table 49 System StateTable 00 49 System StateTable 00 51 Chassis Information Group 71 Chassis Information Group Tables 11 Chassis Information Table 71 UUD Tables 52 oma e aon Baa ye EA 84 POSTLogTable 0 000008 86 EventLogTable 88 System BIOS Table 00 91 Firmware Table 2 eee ee ee 98 Intrusion Table ee ee 101 BaseboardTable 103 Chassis Information Group Variable Values 108 Contents 7 Operating System Group 123 Operating System Group Table 123 Operating System Table 123 Operating System M emory Table 125 8 System Resource Group 129 System Resource Group Tables 129 System ResourceMapTable 129 System Resource Owner Table 131 System Resource Input Output I O Port Table 134 System Resource Memory Table 137 System Resource InterruptTable 140 System Resource Direct Memory Access
174. 50 1 Description Defines the M onitor Port Table entry Syntax M onitorPortTableE ntry Access Not accessible Index monitorPortchassisI ndex monitorPortI ndex Monitor Port Chassis Index Name monitorPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only PortGroup 239 Monitor Port Index Name monitorPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 2 Description Defines the index of the monitor ports in this chassis Syntax DellO bjectRange Access Read only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 3 Description Defines the capabilities of the monitor port Syntax D ellStateC apabilities Access Read only Monitor Port State Settings Name monitorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 4 Description Defines the state of the monitor port Syntax DellStateSettings Access Read write Monitor Port Status Name monitorPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 5 Description Defines the status of the monitor port Syntax DellStatus Access Read only 240 Port Group Monitor Port Security State Name monitorPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 6 Description Defines the security settings of the monitor port Syntax D ellPortSecurityState Access Read only Monitor Port Connect
175. 600 10 1 16 Description Defines the name of the extended warranty provider for this system Syntax D ellC ostofO wnershipString Access Read write COO Ownership Code Name cooOwnershipCode Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 17 Description Defines the ownership code for this system Syntax DellC o00 wnershipC odes See Table 19 1 Access Read write COO Corporate Owner Name Name cooCorporateOwnerName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 18 Description Defines the name of the corporation that owns this system Syntax DellC ostofO wnershipString Access Read write COO Hazardous Waste Code Name Name cooHazardousWasteCodeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 19 Description Defines the hazardous waste code for this system Syntax DellC ostofO wnershipString Access Read write 442 l Cost of Ownership Group COO Deployment Date Length Name cooDeploymentDateLength Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 20 Description Defines the deployment time for this system Syntax DellUnsigned32BitRange Access Read write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 21 Description Defines the deployment time units for this system Syntax DellC ooH ourD ayD urationType See Table 19 2 Access Read write COO Training Name Name cooTrainingName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 22 Description Defines the training that the user
176. 674 10892 1 1100 90 1 8 Description Defines the service name of the network device Syntax DellString Access Read only Device Group 305 Network Device Driver Image Path Name Name Object ID Description Syntax Access networkDeviceDriverImagePathName 1 3 6 1 4 1 674 10892 1 1100 90 1 9 Defines the path to the binary image of the driver for the network device DellString Read only Network Device Driver Version Name Name Object ID Description Syntax Access networkDeviceDriverVersionName 1 3 6 1 4 1 674 10892 1 1100 90 1 10 Defines the version of the driver for the network device DellString Read only Network Device IP Address Name Object ID Description Syntax Access networkDevicelIPAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 11 Defines the IP address of the network device pAddress Read only Network Device IP Subnet Mask Name Object ID Description Syntax Access networkDevicelIPSubnetMask 1 3 6 1 4 1 674 10892 1 1100 90 1 12 Defines the IP subnet mask for the IP address currently assigned to the network device pAddress Read only 306 Device Group Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 13 Description Defines the IP address of the default gateway for the network device Syntax pAddress Access Read only Network Device DHCP Server IP Address Na
177. 7 COO Service Contract Table The service contract table provides M IB objects that help you track the name vendor and type of service contract you have for your system Name cooServiceContractTable Object ID 1 3 6 1 4 1 674 10892 1 1600 20 Description Defines the COO Service C ontract Table Syntax SEQUENCE OF CooServiceC ontractTableE ntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 Description Defines the COO Service C ontract Table entry Syntax CooServiceC ontractTableE ntry Access Not accessible Index cooServiceC ontractchassis ndex cooServiceC ontractl ndex COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only COO Service Contract Index Name cooServiceContract Index Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 2 Description Defines the index one based of this service contract Syntax DellO bjectRange Access Read only 448 Cost of Ownership Group COO Service Contract State Name cooServiceContractState Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 3 Description Defines the status of the service contract for this system Syntax DellStateSettings Access Read only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1
178. 74 10892 1 1100 30 1 1 Defines the index one based of this chassis DellO bjectRange Read only Processor Device Index Name Object ID Description Syntax Access processorDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 30 1 2 Defines the index of the processor device in this chassis DellO bjectRange Read only DeviceGroup 267 Processor Device State Capabilities Name Object ID Description Syntax Access processorDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 3 Defines the capabilities of the processor device DellStateC apabilities Read only Processor Device State Settings Name Object ID Description Syntax Access processorDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 4 Defines the state of the processor device DellStateSettings Read write Processor Device Status Name Object ID Description Syntax Access processorDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 30 1 5 Defines the status of the processor device DellStatus Read only Processor Port Index Reference Name Object ID Description Syntax Access processorPortIndexReference 1 3 6 1 4 1 674 10892 1 1100 30 1 6 Defines the index to the associated processor port in this chassis DellO bjectRange Read only 268 Device Group Processor Device Type Name Object ID Description Syntax Access processorDeviceTyp 1 3 6 1 4 1 674 10892 1 1100 30 1 7 Defines the type of processor device
179. 74 10892 1 200 10 1 7 1 03 1 3 6 1 4 1 674 10892 1 200 10 1 8 1 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 9 1 3 1 3 6 1 4 1 674 10892 1 200 10 1 10 1 03 03 ae E E 7S 10892 AO EE S E 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 12 1 ll Ww 1 3 6 1 4 1 674 10892 1 200 10 1 13 1 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 1 3 6 1 4 1 674 10892 1 200 10 1 20 1 02 02 02 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 21 1 ll Ww 796 SNMP Sample Output 356 3 6 3 6 33 22 23 20 w WO U U U U U U U UU U Chas 62418 6 6 6 6 6 v6cL 6 6 6 6 a6 si EENE ANE ae mE 4 03 03 03 03 0 4 A ok a gaci t Aco 02 02 0 Leese Ord 4nd 4 03 03 03 03 Ieee nL Arsal ee a 2 02 674 1 674 1 1 02 02 02 02 02 02 NE EE Ove OTA 1 674 1 03 03 03 03 03 03 674 10892 1 674 1 OVAL 674 1 26 F Ar A 674 1 674 1 674 1 OTL ene 674 1 674 1 oe E oE 1 674 1 674 1 Ropi a 3 v 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 0892 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 200 1 300 1 300 1 300 1 300 1 300 1 300z I 300 1
180. 9 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax Integer Access Read only Controller C1 Channel Name controllerClChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 30 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax Integer Access Read only Controller C1 Operating System Controller Name controllerCcl0OSController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 31 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller Battery State C1 Name controllerClBatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 32 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax Integer Access Read only 572 Storage Management Group Controller Node World Wide Name Name controllerNodewwN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 33 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 1 World Wide Name Name controllerCOPort1WWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 34 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1 3 6 1 4 1
181. 92 1 600 10 1 5 Defines the redundancy status of the power unit DellStatusR edundancy Read only Power Supply Count for Redundancy Name Object ID Description Syntax Access Power Unit Name Name Object ID Description Syntax Access powerSupplyCountForRedundancy 1 3 6 1 4 1 674 10892 1 600 10 1 6 Defines the total number of power supplies required for this power unit to have redundancy DellString Read only powerUnitName 1 3 6 1 4 1 674 10892 1 600 10 1 7 Defines the name of the power unit in this chassis DellString Read only Power Group 153 Power Unit Status Name powerUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 8 Description Defines the status of the power unit in this chassis Syntax DellStatus Access Read only Power Supply Table Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10892 1 600 12 Description Defines the Power Supply Table Syntax PowerSupplyTableE ntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 Description Defines the Power Supply Table entry Syntax PowerSupplyTableE ntry Access Not accessible Index powerSupplychassisl ndex powerSupplyl ndex Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 154 l Power Group Power Supply
182. AGP2X 16 The system slot isan AGP 2x card systemSlot IsAGP4X 17 The system slot isan AGP 4x card SlotGroup 357 Table 15 3 System Slot Type continued Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20 18 The system slot is a PC 98 C 20 systemSlotIsPC98C24 19 The system slot is a PC 98 C 24 systemSlotIsPC98E 20 The system slot type is PC 98 E systemSlotIsPC98LocalBus 21 The system slot type is a PC 98 local bus systemSlotIsPC98Card 22 The system slot type is a PC 98 card systemSlotIsPCIX 23 The system slot type is a PCIX card systemSlotIsPCIExpress 24 The system slot type is a PCI Express card systemSlotIsAGP8xX 25 The system slot type is an AGP 8x card systemSlotIsPCIExpressX1 166 The system slot type is a PCI Express x1 systemSlotIsPCIExpressX2 167 The system slot type is a PCI Express x2 systemSlotIsPCIExpressX4 168 The system slot type is a PCI Express x4 systemSlotIsPCIExpressX8 169 The system slot type is a PCI Express x8 systemSlotIsPCIExpressX16 170 The system slot type is a PCI Express x16 systemSlotIsPCIExpressGen2 171 The system slot type is PC Express Gen 2 systemSlotIsPCIExpressGen2X1 172 The system slot typeis PCI Express Gen 2 x1 systemSlot IsPCIExpressGen2X2 173 The system slot type is PCI Exp
183. Access memoryDeviceMappedAddressTabl 1 3 6 1 4 1 674 10892 1 1100 60 Defines the M emory D evice M apped Address Table SEQUENCE OF MemoryDeviceM appedAddressT ableE ntry Not accessible Memory Device Mapped Address Table Entry Name Object ID Description Syntax Access Index memoryDeviceMappedAddressTableEntry 1 3 6 1 4 1 674 10892 1 1100 60 1 Defines the M emory D evice M apped Address Table entry M emoryD eviceM appedAddressT ableE ntry Not accessible memoryD eviceM appedAddresschassisl ndex memoryD eviceM appedAddressl ndex Memory Device Mapped Address Chassis Index Name Object ID Description Syntax Access memoryDeviceMappedAddresschassisIndex 1 3 6 1 4 1 674 10892 1 1100 60 1 1 Defines the index one based of this chassis DellO bjectRange Read only DeviceGroup 291 Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 2 Description Defines the index one based of the memory device mapped address in this chassis Syntax DellO bjectRange Access Read only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 3 Description Defines the capabilities of the memory device mapped address Syntax DellStateC apabilities Access Read only Memory Device Mapped Address State Settings Name memoryDeviceMappedAddressStateSettings
184. BatteryNumber 1 3 6 1 4 1 674 10893 1 20 130 16 1 3 Identifies the instance number in the batteryTable of the battery in this connection Integer Read only Battery Connection Controller Name Name Object ID Description Syntax Access batteryConnectionControllerName 1 3 6 1 4 1 674 10893 1 20 130 16 1 4 Identifies the name of the controller as represented in Storage Management to which this battery belongs DisplayString Read only Battery Connection Controller Number Name Object ID Description Syntax Access batteryConnectionControllerNumber 1 3 6 1 4 1 674 10893 1 20 130 16 1 5 Identifies instance number of the controller in the controllerTable to which this battery belongs Integer Read only Storage Management Group 655 Logical Devices Group The Logical Devices Management Information Base M IB group provides information about the logical devices managed by the Dell Storage M anagement Software and their relationships to each other This group and all of its associated tables and objects are not supported on Microsoft W indows Advanced Server Limited Edition 64 bit operating system W indows Net 64 on a Dell PowerEdge 7150 T he following MIB tables define objects and relationships or connections among the objects in the Logical Devices Group e Virtual D isk Table describes available properties for each virtual disk on the managed system Array Disk Logical C onnection Table
185. Bit 0 Virtualization Technology VT supported Bit 1 Demand Based Switching DBS supported Bit 2 eXecute Disable XD supported Bit 3 H yper T hreading HT supported DellUnsigned16BitRange Read only DeviceGroup 273 Processor Device Extended Settings Name Object ID Description Syntax Access processorDeviceExtendedSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 22 This attribute defines extended settings of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit 0 Virtualization Technology VT enabled Bit 1 Demand Based Switching DBS enabled Bit 2 eXecute Disable XD enabled Bit 3 H yper T hreading HT enabled DellU nsigned16BitRange Read only Processor Device Brand Name Name Object ID Description Syntax Access processorDeviceBrandName 1 3 6 1 4 1 674 10892 1 1100 30 1 23 Defines the brand of the processor device DellString Read only Processor Device Model Name Name Object ID Description Syntax Access 274 processorDeviceModelNam 1 3 6 1 4 1 674 10892 1 1100 30 1 24 Defines the model of the processor device DellString Read only Device Group Processor Device Stepping Name Name Object ID Description Syntax Access processorDeviceSteppingName 1 3 6 1 4 1 674 10892 1 1100 30 1 25 Defines the stepping of the processor device DellString Read only Pro
186. BitRange Access Read only Management Information Base Maintenance Version Number Name mIBMaintenanceVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 3 0 Description Defines the maintenance version number for the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the maintenance version number is 3 Syntax DellU nsigned8BitRange Access Read only 42 Instrumentation M IB Version Group Systems Management Software Group The Systems M anagement Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis The Systems M anagement Software Group classifies each computer chassis according to the systems management standard that the agent supports Additional objects define the universal resource locator URL of the systems management software and the language in which systems management information displays D efining these objects enables users to manage a system using an internet browser You can access Server Administrator using the secure hypertext transfer protocol https and a pre assigned port number of 1311 or you can specify a port number of your own choosing K NOTE Using the Software gt Server Preferences menu of Server Administrator you can bind to either one IP address or to all IP addresses To manage a system locally using Server Administrator type the following in
187. C Serial Interface Table Entry Syntax BmcSeriallnterfaceT ableE ntry Access Not accessible Index bmcSeriall nterfaceC hassisl ndex bmcSeriall nterfaceBM C Index bmcSeriall nterfacel ndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 1 Description Defines the index one based of the associated chassis Syntax DellO bjectRange Access Read only BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 2 Description Defines the index one based of the associated BMC Syntax DellO bjectRange Access Read only BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 3 Description Defines the index one based of the BMC serial interface Syntax DellO bjectRange Access Read only 536 Baseboard M anagement Controller Group BMC Serial Interface State Capabilities Name Object ID Description Syntax Access bmcSerialInterfaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1900 20 1 4 Defines the state capabilities of the BMC serial interface DellStateC apabilities Read only BMC Serial Interface State Settings Name Object ID Description Syntax Access bmcSerialInterfaceStateSettings 1 3 6 1 4 1 674 10892 1 1900 20 1 5 Defines the state settings of the BMC serial interface DellStateSettings Read write BMC Serial Interface Status Name O
188. CE OF SystemResourceO wnerTableE ntry Access Not accessible System Resource Group 131 System Resource Owner Table Entry Name Object ID Description Syntax Access Index systemResourceOwnerTabl 1 3 6 1 4 1 674 10892 1 500 20 1 Defines the System Resource O wner Table entry Variables in this group reference the System Resource M ap index SystemResourceO wnerTableE ntry Not accessible systemR esourceO wnerchassisI ndex systemR esourceO wnerl ndex System Resource Owner Chassis Index Name Object ID Description Syntax Access systemResourceOwnerchassisIndex 1 3 6 1 4 1 674 10892 1 500 20 1 1 Defines the index one based of this chassis DellO bjectRange Read only System Resource Owner Index Name Object ID Description Syntax Access systemResourceOwnerIndex 1 3 6 1 4 1 674 10892 1 500 20 1 2 Defines the index of system resource owners for this chassis DellO bjectRange Read only System Resource Owner State Capabilities Name Object ID Description Syntax Access systemResourceOwnerStateCapabilities 1 3 6 1 4 1 674 10892 1 500 20 1 3 Defines the capabilities of this system resource owner DellStateC apabilities Read only 132 System Resource Group System Resource Owner State Settings Name Object ID Description Syntax Access systemResourceOwnerStateSettings 1 3 6 1 4 1 674 10892 1 500 20 1 4 Defines the state settings of this system resource owner D
189. CategorylIsOther 1 The system slot category is not one of following systemSlotCategoryIsUnknown 2 The system slot category is unknown systemSlotCategoryIsBusConnector 3 The system slot is a bus connector systemSlotCategoryIsPCMCIA 4 The system slot category is PCMCIA systemSlotCategoryIsMotherboard 5 The system slot isa motherboard Table 15 7 Hot Plug Bus Width Variable Name Del 1SystemSlotHotPlugBusWidth Data Type Integer Possible Data Values Meaning of Data Value busWidthIsOther 1 The system slot bus width is not one of following busWidthIsUnknown 2 The system slot bus width is unknown busWidthIs8bits 3 The system slot bus width is 8 bits busWidthIsl6bits 4 The system slot bus width is 16 bits busWidt hIs32bits 5 The system slot bus width is 32 bits busWidt hIs64bits 6 The system slot bus width is 64 bits busWidt hIsl28bits 7 The system slot bus width is 128 bits busWidt hIslxOrx1 8 The system slot bus width is 1x or x1 busWidt hIs2xOrx2 9 The system slot bus width is 2x or x2 busWidt hIs4xOrx4 10 The system slot bus width is 4x or x4 busWidt 360 hIs8xOrx8 11 Slot Group The system slot bus width is 8x or x8 Table 15 7 Hot Plug Bus Width continued Variable Name Del 1SystemSlotHotPlugBusWidth Data Type Integer Possible Data Values Meaning of Data Value busWidth
190. DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 12 Description Defines the system events filter capabilities of this remote access SN MP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Control Capabilities Name remoteSNMPTrapControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 13 Description Defines the control capabilities of this remote access SNMP trap destination Syntax DellRemoteSN M PTrapC ontrolC apabilities See Table 20 20 Access Read only Remote SNMP Trap Control Settings Name remoteSNMPTrapControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 14 Description Defines the control settings of this remote access SNM P trap destination Syntax DellRemoteSN M PTrapC ontrolSettings See Table 20 21 Access Read write Remote Access Group 499 Remote Dial Up Table Name Object ID Description Syntax Access remoteDialUpTable 1 3 6 1 4 1 674 10892 1 1700 40 Defines the Remote Access Dial Up Table SEQUENCE OF RemoteDialU pTableEntry Not accessible Remote Dial Up Table Entry Name Object ID Description Syntax Access
191. Dell OpenM anage Server Administrator SNMP Reference Guide Notes and Cautions K NOTE A NOTE indicates important information that helps you make better use of your computer VAN A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed Information in this publication is subject to change without notice 2003 2012 Dell Inc All rights reserved Reproduction of these materials whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo PowerEdge PowerVault and OpenManage are trademarks of Dell Inc Microsoft and Windows are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Intel Itanium Pentium Atom and Celeron are registered trademarks and MMX Xeon and Core are trademarks of Intel Corporation in the United States and or other countries VESA is a registered trademark of the Video Electronics Standards Association AMD AMD Athlon AMD Opteron AMD Sempron AMD Turion AMD Phenom and AMD Duron are trademarks of Advanced Micro Devices Inc VIA C7 and VIA Eden are either trademarks or registered trademarks of VIA Technology Inc Crusoe and Efficeon are trademarks of Transmeta Corporation in the USA and other countries Other trademarks and trade names may be used in this document to r
192. DellClusterType Read only Cluster Type Description Name Name Object ID Description Syntax Access Cluster Name Name Object ID Description Syntax Access clusterTypeDescriptionName 1 3 6 1 4 1 674 10892 1 1800 10 1 7 Defines the description name for the type of the cluster DellString Read only clusterName 1 3 6 1 4 1 674 10892 1 1800 10 1 8 Defines the name of the cluster DellString Read only Cluster Group 529 530 Cluster Group Variable Values This section includes definitions for Server Administrator specific variable values used in this section Table 21 1 Cluster Type Variable Name De11ClusterType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The cluster type is unknown highAvailabilityCluster 2 Thecluster type is a high availability cluster Cluster Group Baseboard Management Controller Group The Baseboard M anagement Controller BMC monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds The BMC Group provides information about the BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BMC Baseboard Management Controller Group Tables The objects in the BMC group
193. ER 1 2147483647 DellSigned32BitRange INTEGER 2147483647 2147483647 DellBoolean INTEGER 0 1 FALSE 0 TRUE 1 Standard Data Type Definitions 789 Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of lt variable name gt StateCapabilitiesor lt variable name gt StateCapabilitiesUnique are integers representing a series of bit definitions They are NOT enumerations and should be treated as bit fields T he value is passed as a decimal value T he decimal value should be converted to hex and the appropriate bits should be parsed from hex Some of the more common bit combinations are defined in some variables but not all combinations are or will be defined Table 30 2 Dell State Capabilities Variable Name De11StateCapabilities Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities unknownCapabilities 1 The object s capabilities are unknown enableCapable 2 The object can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The object is not ready enableAndNotReadyCapable Enable and not ready capable 6 790 Standard Data Type Definitions Table 30 3 Dell State Settings Variable Name De11StateSettings Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The obj
194. Floppy for Toshiba 1 2mb 3 5 in 360 RPM is supported Bit 22Int 13h 5 25 in 360 KB Floppy Services are supported Bit 23Int 13h 5 25 in 1 2M B Floppy Services are supported Bit 24Int 13h 3 5 in 720 KB Floppy Services are supported Bit 25 nt 13h 3 5 in 2 88 MB Floppy Services are supported Bit 26Int 5h Print Screen Service is supported Bit 27Int 9h 8042 Keyboard services are supported Bit 28Int 14h Serial Services are supported Bit 29Int 17h Printer Services are supported Bit 30Int 10h CGA M ono Video Services are supported Bit 3INEC PC 98 Bit 32 47Reserved Bit 48Built in NIC supports M agic Packet Bit 49System supports W ake on LAN Bit 50System supports chassis intrusion Bit 51Built in NIC supports pattern matching Bit 52System BIOS supports a 7 character service tag Bit 53 63Reserved Syntax DellU nsigned64BitR ange 96 Chassis Information Group System BIOS Characteristics Ext 1 Name Object ID Description Syntax Access systemBIOSCharacteristicsExtl 1 3 6 1 4 1 674 10892 1 300 50 1 13 Defines additional characteristics of the system basic input output system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit OAC PI supported Bit LUSB Legacy is supported Bit 2AGP is supported Bit 3120 boot is supported Bit 4LS 120 boot is supported Bit 5ATAPI ZIP Drive boot is supported Bit 61394 boot is support
195. IB IDRAC7 Out of Band Group The objects of the Integrated D ell Remote Access C ontroller iD RAC MIB iD RAC M IB txt are organized into subgroups of the iD RAC 7 Out of Band Group The subgroups are e RAC Information Group e Chassis Information Group e System Information Group e Status Group The following sections document the subgroups and the objects within each subgroup RAC Information Group The RAC Information Group objects provide information about the iD RAC RAC Name Name racName Object ID 1 3 6 1 4 1 674 10892 5 1 1 1 0 Description This attribute defines the product name of a remote access card Syntax StringType Access Read only RAC Short Name Name racShortName Object ID 1 3 6 1 4 1 674 10892 5 1 1 2 0 Description This attribute defines the short product name of a remote access card Syntax StringType Access Read only 740 iDRAC7 MIB RAC Description Name racDescription Object ID 1 3 6 1 4 1 674 10892 5 1 1 3 0 Description This attribute defines the product description of a remote access card Syntax StringType Access Read only RAC Manufacturer Name racManufacturer Object ID 1 3 6 1 4 1 674 10892 5 1 1 4 0 Description This attribute defines the product manufacturer of a remote access card Syntax StringType Access Read only RAC Version Name racVersion Object ID 1 3 6 1 4 1 674 10892 5 1 1 5 0 Description This attribute defines the product version of a remote access card
196. IdentifyControlSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The chassis identification control s state is unknown enabled 2 The chassis identification control s state is disabled offline a binary 0 value or enabled online a binary 1 value not Ready 4 The chassis identification control s state is not ready identifyChassis 8 The chassis identification control s LEDs may be returned to normal 0 or identify chassis 1 identifyChassisAndEnable The chassis identification control s 10 LEDs may be returned to normal a binary 0 value or identify chassis and enabled a binary 1 value Chassis Information Group 113 Table 6 11 Host Control Capabilities Variable Name Del 1HostControlCapabilities NOTE An operator can manually enable these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualRebootCapable 1 The operator can reboot capable host manualPowerOFFCapable 2 The operator can power off capable host manualPowerCycleCapable 4 The operator can power cycle capable host manualAllExceptOperating SystemShutdownCapable 7 The operator can reboot and power off capable host manualOperatingSystemShut downCapable 8 The operator can shut down the operating system shutdown capable host manualFullyCapable 15 The operator can reboot power
197. Is12xOrx12 12 The system slot bus width is 12x or x12 busWidthIs16xOrx16 13 The system slot bus width is 16x or x16 busWidthIs32x0rx32 14 The system slot bus width is 32x or x32 K NOTE System slot bus width of type n bits are for parallel buses such as PCI K NOTE System slot bus width of type nx or xn are for serial buses such as PCI Express SlotGroup 361 362 Slot Group Memory Group The Memory Group provides information about the physical memory in your system Variables in this group include error correction type location and different types of memory use such as cache flash system video and nonvolatile memory Physical Memory Tables The following management information base M IB tables define the objects in the Memory Group Physical Memory Array Table on page 363 Physical Memory Array M apped Table on page 368 e Physical Memory Configuration Table on page 371 Physical Memory Logging Table on page 374 e Redundant Memory Unit Table on page 376 Physical Memory Card Table on page 379 Physical Memory Array Table The physical memory array is the entire physical memory of a system The example that follows shows variable values for a system that has one 128 megabyte M B dual in line memory module DIMM e physicalM emoryArrayM aximumSize 2 097 152 kilobytes KB or 2 gigabytes GB e physicalM emoryArrayTotalN umberSockets 4 the example system
198. LV 167 Xeon processor U LV deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n7100 168 Xeon processor 7100 Series deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n5400 169 Intel Xeon processor 5400 Series deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n 170 Intel Xeon deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n5200 171 Xeon processor 5200 Series deviceFamilyIsDualCoreIntelXeo Theprocessor family is D ual C ore Intel n7200 172 Xeon processor 7200 Series deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n7300 173 Intel Xeon processor 7300 Series deviceFamilyIsQuadCoreIntelXeo The processor family is Quad C ore n7400 174 Intel Xeon processor 7400 Series deviceFamilyIsMultiCoreIntelXe The processor family is M ulti C ore on7400 175 Intel Xeon processor 7400 Series deviceFamilyIsM1 176 The processor family is M 1 330 Device Group Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsM2 177 The processor family is M 2 deviceFamilyIsIntelPentium4HT The processor family isIntel Pentium 4 179 HT processor deviceFamilyIsAS400 180 The processor family is AS400 deviceFamilyIsAMDAthlonxP 182 The processor f
199. Management Protocol SNMP Settings Variable Name De 1 1RemoteAccessOutOfBandSNMPSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no out of band SNMP settings unknown 1 The remote access hardware out of band SNM P settings are unknown oobSNMPAgentEnabled 2 The remote access hardware out of band SNM P agent is enabled oobSNMPTrapsEnabled 4 The remote access hardware sends out of band SNMP traps Table 20 12 Remote User Admin State Capabilities Variable Name De 1 1RemoteUserAdminStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no state capabilities unknownCapabilities 1 The admin user state capabilities are unknown enableCapable 2 The admin user can be disabled or enabled notReadyCapable 4 The admin user can be in the not ready state numericPagerCapable 8 The admin user supports numeric paging alphaPagerCapable 16 The admin user supports alphanumeric paging emailCapable 32 The admin user supports e mail privilegeCapable 64 The admin user supports user privileges configuration 516 Remote Access Group Table 20 13 Remote User Admin State Settings Variable Name De 1 1RemoteUserAdminStateSettings Data Type Integer Possible Data Val
200. MemoryDeviceStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 28 Description Defines the status of all memory devices in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the status of a specific memory device The first byte returned represents the status of the first memory device the second byte returned represents the status of the second memory device and so on The bytes have the same definition type as DellStatus Syntax Octet String Size 1 128 Access Read only 60 System State Group System State Chassis Intrusion State Details Name Object ID Description Syntax Access systemStateChassisIntrusionStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 29 Defines the intrusion state of all intrusion detection devices in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the status of a specific intrusion detection device T he first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on T he bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only System State Chassis Intrusion Status Combined Name Object ID Description Syntax Access systemStateChassisIntrusionStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 30 Defines the int
201. Not accessible Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 Description Defines the temperature probe connection table entry Syntax TemperatureC onnectionE ntry Access Not accessible Index temperatureC onnectionN umber 638 Storage Management Group Temperature Probe Connection Number Name Object ID Description Syntax Access temperatureConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 12 1 1 Identifies the instance number of the temperature probe connection entry Integer Read only Temperature Probe Connection Temperature Probe Name Name Object ID Description Syntax Access temperatureConnectionTemperatureNam 1 3 6 1 4 1 674 10893 1 20 130 12 1 2 Identifies the name of the temperature probe in this connection as represented in Storage M anagement DisplayString Read only Temperature Probe Connection Temperature Probe Number Name Object ID Description Syntax Access temperatureConnectionTemperatureNumber 1 3 6 1 4 1 674 10893 1 20 130 12 1 3 Identifies the instance number in the temperatureT able of the temperature probe in this connection Integer Read only Temperature Probe Connection Enclosure Name Name Object ID Description Syntax Access temperatureConnectionEnclosureName 1 3 6 1 4 1 674 10893 1 20 130 12 1 4 Identifies the name of the enclosure as represented in Storage
202. Number Name powerSupplyConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this power supply belongs Syntax Integer Access Read only 632 Storage Management Group Temperature Probe Table This table describes available properties for each temperature probe on the managed system The following object sets up the Temperature Probe Table Name Object ID Description Syntax Access temperatureProbeTabl 1 3 6 1 4 1 674 10893 1 20 130 11 A table of managed temperature probes T he number of entries is related to the number of temperature probes discovered in the system The maximum number of entries is implementation dependent NOTE The properties in this table may not be applicable to all entries SEQUENCE OF TemperatureProbeE ntry Not accessible Temperature Probe Entry Name Object ID Description Syntax Access Index temperatureProbeEntry 1 3 6 1 4 1 674 10893 1 20 130 11 1 An entry in the Temperature Probe Table A row in this table cannot be created or deleted by SNMP operations on columns of the table TemperatureProbeE ntry Not accessible TemperatureProbeN umber Temperature Probe Number Name Object ID Description Syntax Access temperatureProbeNumber 1 3 6 1 4 1 674 10893 1 20 130 11 1 1 Identifies the instance number of the temperature probe entry In
203. Numbers 19 Remote Access Group providesinformation about remote 1700 access hardware that may be present in your system and defines variables for administrative users SN MP trap destinations modem configuration for dial up networking dial in configuration and dial out destinations Server Administrator Baseboard Management Controller ASF MIB The Server Administrator BMC MIB filename D cAsfSrumib provides information about the traps sent by BM C The Server Administrator BM C M IB structures its M IB objects that provide related information The BM C MIB groups are identified by the SNMP OID 1 3 6 1 4 1 3183 1 1 lt MIB group number gt The BMC MIB adheres to ASF 2 0 standard and hence the enterprise ID is wired for management 3183 Introduction 21 Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit M IB filename dcs3fru mib provides information about field replaceable unit FRU hardware that may be present in your system The Server Administrator Field Replaceable Unit M IB structures its MIB objects into groups of scalar objects or M IB tables that provide related information Table 1 4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the M IB group The Server Administrator Field Replaceable Unit M IB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt M IB group
204. OID Name DRsAlertTableIndexOID Object ID 1 3 6 1 4 1 674 10892 2 5000 10 2 Description Alert Index Object Identifier Syntax OBJECT IDENTIFIER Access Read Only DRsAlertMessage Name DRsAlertMessage Object ID 1 3 6 1 4 1 674 10892 2 5000 10 3 Description M essage describing the alert Syntax Octet String SIZE 0 1024 Access Read only 714 Dell Remote Access Controller Out of Band Group DRsAlertCurrentStatus Name Object ID Description Syntax Access DRsAlertCurrentStatus 1 3 6 1 4 1 674 10892 2 5000 10 4 Current status of object causing the alert DellStatus Read only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1 3 6 1 4 1 674 10892 2 5000 10 5 Description Previous status of object causing the alert Syntax DellStatus Access Read only DRsAlertData Name DRsAlertData Object ID 1 3 6 1 4 1 674 10892 2 5000 10 6 Description Alert data Syntax Octet String SIZE 0 1024 Access Read only Dell Remote Access Controller Out of BandGroup 715 716 Dell Remote Access Controller Out of Band Group Traps The Server Administrator generates events that result in Simple Network Management Protocol SN M P traps or operating system event logs Remote Access C ontroller RAC and Baseboard M anagement C ontroller BMC can also generate SN MP traps in response to hardware events T his section describes the traps also known as alerts generated by the Server Administrator RAC and BMC Th
205. Object ID Description Syntax Access systemSlotCurrentUsage 1 3 6 1 4 1 674 10892 1 1200 10 1 6 Defines the current usage of the system slot DellStatus Read only systemSlotType 1 3 6 1 4 1 674 10892 1 1200 10 1 7 Defines the type of the system slot D ellSystemSlotType See Table 15 3 Read only System Slot External Slot Name Name Object ID Description Syntax Access systemSlotSlotExternalSlotName 1 3 6 1 4 1 674 10892 1 1200 10 1 8 Defines the external connector name of the system slot DellString Read only SlotGroup 351 System Slot Length Name Object ID Description Syntax Access systemSlotLength 1 3 6 1 4 1 674 10892 1 1200 10 1 9 Defines the length of the system slot DellSystemSlotL ength See Table 15 5 Read only System Slot Slot ID Name Object ID Description Syntax Access systemSlotSlotID 1 3 6 1 4 1 674 10892 1 1200 10 1 10 Defines the slot identification number of the system slot A zero 0 indicates that the slot is embedded on the motherboard D ellU nsigned32BitR ange Read only System Slot Category Name Object ID Description Syntax Access systemSlotCategory 1 3 6 1 4 1 674 10892 1 1200 10 1 11 Defines the system slot category DellUnsigned32BitR ange Read only System Slot Hot Plug Bus Width Name Object ID Description Syntax Access 352 systemSlotHotPlugBusWidth 1 3 6 1 4 1 674 10892 1 1200 10 1 12 Defines the bus width of the hot
206. Object ID 1 3 6 1 4 1 674 10892 2 4 1 Description Definesthe CMC power table Syntax SEQUENCE OF DrsCMC PowerTableEntry Access Not accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 Description Definesthe CMC power table entry Syntax DrsC M C PowerTableE ntry Access Not accessible DRsCMC PSUTable Name DrsCMCPSUTable Object ID 1 3 6 1 4 1 674 10892 2 4 2 Description Definesthe CMC PSU table Syntax SEQUENCE OF DrsCMCPSUTableEntry Access Not accessible Dell Remote Access Controller Out of BandGroup 705 DRsCMC PSUTableEntry Name Object ID Description Syntax Access DrsCMCPSUTableEntry 1 3 6 1 4 1 674 10892 2 4 2 1 Definesthe CMC PSU table entry DrsCM CPSU TableE ntry Not accessible CMC Power Information The following M IB tables provide information on the chassis power DRsChassisIndex Name DrsChassisIndex Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 1 Description Defines the index one based of the associated chassis Syntax DellC M C Powerl ndexRange Access Read only DRsPotentialPower Name DRsPotentialPower Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 2 Description Defines the power in Watts required by the chassis infrastructure plus the sum of the maximum power requirements for all systems currently turned on Syntax D ellPowerReading Access Read only 706 Dell Remote Access Controller Out of Band Group DRsldlePower Name Object ID
207. PARC II deviceFamilyIsmicroSPARCIIep 83 The processor family is microSPARC Ilep deviceFamilyIsUltraSPARC 84 The processor family is UltraSPARC deviceFamilyIsUltraSPARCII 85 The processor family is UltraSPARC II DeviceGroup 327 Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIIi 86 The processor family isUltraSPARC Ili deviceFamilyIsUltraSPARCIII 87 The processor family is UltrasPARC Il deviceFamilyIsUltraSPARCIIIi The processor family is UltraSPARC 88 Ili deviceFamilyIs68040 96 The processor family is 68040 Family deviceFamilyIs68xxx 97 The processor family is 68xxx deviceFamilyIs68000 98 The processor family is 68000 deviceFamilyIs68010 99 The processor family is 68010 deviceFamilyIs68020 100 The processor family is 68020 deviceFamilyIs68030 101 The processor family is 68030 deviceFamilyIsHobbit 112 The processor family is H obbit deviceFamilyIsCrusoe5000 120 The processor family is Crusoe 5000 deviceFamilyIsCrusoe3000 121 The processor family is Crusoe 3000 deviceFamilyIsEfficeon8s000 The processor family is Efficeon 8000 122 deviceFamilyIsWeitek 128 The processor family is W eitek deviceFamilyIsIntelCeleronM 13 The processor family is Intel C eleron
208. PUserName 1 3 6 1 4 1 674 10892 1 1700 60 1 9 Defines the PPP username for this remote access dial out destination DisplayString SIZE 0 31 Read write Remote Access Group 509 Remote Dial Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 10 Description Defines the PPP password for this remote access dial out destination Syntax DisplayString SIZE 0 31 Access Read write Remote Access Variable Values This section includes definitions for server administrator specific variable values used in this section Table 20 1 Remote Access Type Variable Name De 1 1RemoteAccessTyp Data Type Integer Possible Data Values Meaning of Data Value remoteAccessTypelsOther 1 The remote access type is not one of the following remoteAccessTypelsUnknown 2 Theremote access type is unknown remoteAccessTypeIsDRACIII 3 Theremote access type is DRAC III remoteAccessTypelsERA 4 The remote access type is ERA Table 20 2 Remote Access Control Capabilities Variable Name De 1 1RemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no control capabilities unknownCapabilities 1 The remote access hardware control capabilities are unknown 510 Remote Access Group Table 20 2 Remote Access Control Capabilities continued
209. Parallel Port Control Mode Settings Variable Name De11ParallelPortControlModeSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port mode is unknown atModeEnabled 2 Setup BIOS has set the parallel port to AT mode ps2ModeEnabled 4 Setup BIOS has set the parallel port to Personal Systems 2 PS 2 mode ecpModeEnabled 8 Setup BIOS has set the parallel port to Extended Capabilities Port ECP mode eppModeEnabled 16 Setup BIOS has set the parallel port to Enhanced Parallel Port EPP mode Table 17 15 Serial Port Control Capabilities Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Setup BIOS serial port capabilities are unknown enableCapable 2 Setup BIOS can enable the serial port comlCapable 4 Setup BIOS can support serial port 1 enableAndComlCapable 6 Setup BIOS can enable serial port 1 com2Capable 8 Setup BIOS can support serial port 2 enableAndCom2Capable 10 Setup BIOS is capable of enabling serial port 2 com3Capable 16 Setup BIOS can support serial port 3 enableAndCom3Capable 18 Setup BIOS is capable of enabling serial port 3 com4Capable 32 Setup BIOS can support serial port 4 enableAndCom4Capable 34 Setup BIOS is capable of enabling serial port 4 autoConfigC
210. Port Table 242 Parallel Port Table onana aaa 244 Serial Port Table noona aaa 248 Universal Serial Bus USB Port Table 252 Port Group Variable Values 255 Contents 14 Device Group 261 Device Tables 4 261 Pointing Device Table 262 Keyboard Device Table 264 Processor Device Table 267 Processor Device Status Table 275 Cache Device Table 277 Memory Device Table nnna anaana aaa 283 Memory Device Mapped Address Table 291 Generic Device Table 294 PCIDeviceTable 297 PCI Device Configuration Space Table 300 Network Device Table 303 Managed System Services Device Table 311 SDCardUnitTable 313 SD Card Device Table 316 Device Group Variable Values 320 15 Slot Group ws edtine dt oe oe org Bd ee bate 349 System Slot Group Table 349 SystemSlotTable 349 System Slot Variable Values 353 16 Memory Group 34 09 waters Se aw bes 363 Physical Memory Tables 363 Physical M emory Array Table 363 Physical Memory Array M apped Table 368 Physical Memory Configuration Table 371 Physical M emory LoggingTable 374 Redundant M emory UnitTable 376 Contents PhysicalMemoryCardTable
211. Predictive failure Chassis intrusion state lt Intrusion state gt Specifies the chassis intrusion state open or closed for example Chassis intrusion state Open Chassis location lt Name of chassis gt Traps Specifies the name of the chassis that generated the message for example Chassis location Chassis Main System Table 27 1 Trap Description Reference continued Description Line Item Explanation Configuration error type lt type of configuration error gt Specifies the type of configuration error that occurred for example Configuration error type Revision mismatch Current sensor value in Amps lt Reading gt Specifies the current sensor value in amps for example Current sensor value 7 853 Date and time of Specifies the date and time that an automatic action lt Date and time gt server recovery action was performed for example Date and time of action Fri May 30 23 55 44 2003 Description Specifies the description of the event that lt Description of event gt occurred for example Err Description Chipset Critical Event sensor front panel NMI diagnostic interrupt was asserted Device location lt Location in chassis gt Specifies the location of the device in the specified chassis for example Device location Mem Card A Discrete current state Specifies the state of the current sensor for
212. Present Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 5 Description Defines whether storage is present on the managed system services device Syntax DellBoolean Access Read only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 6 Description Defines the size in M egabytes M B of the storage present on the managed system services device Syntax DellUnsigned32BitRange Access Read only SD Card Unit Table Name sdCardUnitTable Object ID 1 3 6 1 4 1 674 10892 1 1100 110 Description Defines the SD Card Unit Table Syntax SEQUENCE OF SdCardUnitTableEntry Access Not accessible SD Card Unit Table Entry Name sdCardUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 Description Defines the SD Card Unit Table Entry Syntax SdC ardU nitTableE ntry Access Not accessible DeviceGroup 313 Name sdCardUnitTableEntry Index sdC ardU nitC hassisl ndex sdC ardU nitl ndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 1 Description Defines the index one based of the chassis that contains the SD Card unit Syntax DellO bjectRange Access Read only SD Card Unit Index Name sdCardUnit Index Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 2 Description Defines the index one based of the SD Card unit Syntax DellO bjectRange Access Read only SD Card Unit State Capabilit
213. Read only Remote Access Product Info Name Name remoteAccessProduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description Defines the description of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Group 473 Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the version of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessLANC apabilities See Table 20 6 Access Read only Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessL AN Settings See Table 20 7 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remo
214. S Health graceful shut down occurred OS Failure 2409 A critical stop occurred System OS Event Critical during OS load ora Health runtime critical stop occurred Table 29 11 PCI Device Traps TrapID Description Category SubCategory Severity PCI Device Information 2419 An informational event System PCI Device Informational was detected fora PCI Health device PCI Device Warning 754 iDRAC7 MIB TrapID Description Category SubCategory Severity 2418 A warning event was System PCI Device Minor detected for a PCI Health device PCI Device Failure 2417 An error was detected for System PCI Device Critical a PCI device Health iDRAC7 MIB 755 Table 29 12 Physical Disk Traps TrapID Description Category SubCategory Severity Physical Disk Information 2299 Physical disk System Physical Disk Informational information Health Physical Disk Warning 2298 Physical disk warning System Physical Disk M inor Health Physical Disk Failure 2297 Physical disk failure System Physical Disk Critical Health Table 29 13 BIOS POST Trap TrapID Description Category SubCategory Severity Bios Post Failure 2425 System BIOS detected a System BIOS POST Critical failure Health Table 29 14 Power Supply Traps TrapID Description Category SubCategory Severity Power Supply Normal 2187 Power supply has System Power Supply Informational returned to normal Health Power Supply W
215. Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 100 4 Description Defines the description of the systems management software Syntax DellString Access Read only 44 Systems M anagement Software Group Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 5 Description Defines the systems management standards SNM P or CIM supported by the systems management software Syntax SM SSupportedTypes See Table 4 1 Access Read only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 6 Description Defines the preferred systems management standard for the systems management software Syntax SM SSupportedTypes See Table 4 1 Access Read only Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelNam Object ID 1 3 6 1 4 1 674 10892 1 100 7 Description Defines the update level of the system management software Syntax DellString Access Read only Systems Management Software URL Name Name systemManagement SoftwareURLName Object ID 1 3 6 1 4 1 674 10892 1 100 8 Description Defines the universal resource locator URL of the systems management software Syntax DisplayString SIZE 0 1024 Systems ManagementSoftware Group 45 Name systemManagement SoftwareURLName Acces
216. StateM emoryD eviceStatusD etails 50 System State Group e systemStateC hassisl ntrusionStatusD etails e systemStateAC PowerC ordStatusD etails e systemStatePowerU nitStatusl ist e systemStateC oolingU nitStatusl ist e systemStateAC PowerSwitchStatusL ist e systemStateR edundantM emoryU nitStatusl ist e systemStateProcessorD eviceStatusl ist e systemStateBatteryStatusL ist e systemStateSD C ardU nitStatusL ist e systemStateSD C ardD eviceStatusL ist System State Table The following object sets up the System State Table Name systemStateTable Object ID 1 3 6 1 4 1 674 10892 1 200 10 Description Defines the System State Table Syntax SEQUENCE OF SystemStateT ableE ntry Access Not accessible System State Table Entry Name systemStateTableEntry Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 Description Defines the System State Table entry Syntax SystemStateT ableE ntry Access Not accessible Index systemStatechassis ndex System State Group 51 System State Chassis Index Name systemStatechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 2 Description Defines the global system status of all chassis being monitored by this instrumentation instance Syn
217. Status Syntax Octet String Size 1 128 Access Read only System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 52 Description Defines the combined status of all batteries of this chassis Syntax DellStatus Access Read only System State Battery Status List Name systemStateBatteryStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 53 68 System State Group Description Syntax Access systemStateBatteryStatusList Lists the status of each battery of this chassis T he results are returned as a binary octet string where each byte of the octet string represents the status of a battery T he first byte returned represents the status of the first battery and so on The bytes have the same definition type as D ellStatus Octet String Size 1 128 Read only System State SD Card Unit Status Combined Name Object ID Description Syntax Access systemStateSDCardUnitStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 54 Defines the combined status of all SD Card units of this chassis DellStatus Read only System State SD Card Unit Status List Name Object ID Description Syntax Access systemStateSDCardUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 55 Lists the status of each SD Card unit of this chassis T he results are returned as a binary octet string where each byte of the octet string represents the status of aSD Card unit The
218. String Object ID 1 3 6 1 4 1 674 10899 1 6 1 5 Description A user visible display string that describes the application Syntax DisplayString Access Read only Application Sub Component ID Name applicationSubComponentID Object ID 1 3 6 1 4 1 674 10899 1 6 1 6 Description The sub component ID for the application This is usually valid on ESM device reporting Syntax DisplayString Access Read only 678 Change M anagement Group Operating System Group The Operating System Group provides status and identifying information about asystem s operating system Identifying information includes the name version and service pack of the installed operating system The following objects describe the fields for O perating System Group Operating System Vendor Name Object ID Description Syntax Access operatingSystemVendor 1 3 6 1 4 1 674 10899 2 1 Defines the vendor of the O perating System DisplayString Read only Operating System Major Version Name Object ID Description Syntax Access operatingSystemMajorVersion 1 3 6 1 4 1 674 10899 2 2 Defines the major version of the Operating System DisplayString Read only Operating System Minor Version Name Object ID Description Syntax Access operatingSystemMinorVersion 1 3 6 1 4 1 674 10899 2 3 Defines the minor version of the O perating System DisplayString Read only ChangeManagementGroup 679 Operating System Service Pack Major Version N
219. SubCategory Severity Storage Management Information 4179 Storage Management Storage Storage Informational information There is no global status change associated with this trap Storage Management Warning 4178 StorageM anagementhas Storage Storage M inor detected a device independent warning condition T here is no global status change associated with this trap Storage Management Failure 4177 StorageM anagementhas Storage Storage Critical detected a device independent error condition T here is no global status change associated with this trap Table 29 34 Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Probe Information 4211 Temperature probe Storage Temperature Informational information Storage Temperature Probe Warning 4210 Temperature probe Storage Temperature Minor warning Storage Temperature Probe Failure 4209 Temperature probe Storage Temperature Critical failure iDRAC7MIB 765 Table 29 35 Virtual Disk Trap TrapID Description Category SubCategory Severity Storage VirtualDisk Information 4355 Virtual disk information Storage Virtual Disk Informational Storage Virtual Disk Warning 4354 Virtual disk warning Storage Virtual Disk Minor Storage Virtual Disk Failure 4353 Virtual disk failure Storage Virtual Disk Critical Updates Trap Group The Updates Trap Group contains traps that fall under the U pdates event category of iD RAC 7 Updates traps are trap
220. Syntax Access networkDeviceRDMACapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 25 Defines the Remote Direct M emory Access RDM A capability flags of the network device DellN etworkD eviceRD M AC apabilityF lags see Table 14 23 Read only Network Device RDMA Enabled Name Object ID Description Syntax Access networkDeviceRDMAEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 26 Defines if RDM A is enabled for the network device DellBoolean Read only Network Device iSCSI Capability Flags Name Object ID Description Syntax Access networkDeviceiSCSICapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 27 Defines the Internet Small Computer System Interface iSCSI capability flags of the network device DellN etworkD eviceiSC SIC apabilityF lags see Table 14 24 Read only Network Device iSCSI Enabled Name Object ID Description Syntax Access 310 networkDeviceiSCSIEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 28 Defines if iSCSI is enabled for the network device DellBoolean Read only Device Group Managed System Services Device Table Name managedSystemServicesDeviceTabl Object ID 1 3 6 1 4 1 674 10892 1 1100 100 Description Defines the M anaged System Services D evice Table Syntax Sequence of M anagedSystemServicesD eviceTable Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100
221. Table describes available properties for each fan on the managed system Fan C onnection Table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Power Supply Table describes available properties for each power supply on the managed system Power Supply C onnection Table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Storage Management Group Temperature Probe Table describes available properties for each temperature probe on the managed system e Temperature Probe C onnection Table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table e EMM Table describes available properties for each Enclosure Management M odule EMM on the managed system EMM Connection Table describes the connection between each EM M on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Battery Table describes available properties for each controller battery on the managed system Battery C onnection Table describes the connecti
222. Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 14 Description Defines the value of the temperature probe s lower nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Thermal Group 211 Temperature Probe Probe Capabilities Name Object ID Description Syntax Access temperatureProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 20 1 15 Defines the probe capabilities of the temperature probe DellProbeC apabilities Read only Temperature Probe Discrete Reading Name Object ID Description Syntax Access temperatureProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 700 20 1 16 Defines the reading for a temperature probe of type temperatureProbeTypel sD iscrete W hen the value for temperatureProbeType is other than temperatureProbeTypelsD iscrete a value is not returned for this attribute W hen the value for temperatureProbeType is temperatureProbeTypelsD iscrete the value returned for this attribute is the discrete reading for the probe DellTemperatureD iscreteR eading See Table 10 5 Read only 212 Thermal Group Thermal Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 10 1 Cooling Device Type Variable Name De1 1CoolingDeviceType Data Type Integer
223. Temperature Warning Cleared Information 65794 Under Temperature Problem Lower Critical going low Critical 65922 Under Temperature Problem Cleared Information 65799 OverTemperature warning U pper non critical going high M inor 65927 Over Temperature warning Cleared Information 65801 Over Temperature Problem Upper Critical going high Critical 65929 Over Temperature Problem Cleared Information 131328 Under Voltage Warning Lower Non Critical going low Warning 131456 Under Voltage Warning Cleared Information 131330 Under Voltage Problem Lower Critical going low Critical 131458 Under Voltage Problem Cleared Information 131335 Over Voltage W arning U pper Non Critical going high Warning 131463 OverVoltage Warning Cleared Information 131337 Over Voltage Problem U pper Critical going high Critical 131465 OverVoltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem C leared Information 356096 Chassis Intrusion Physical Security Violation Critical 356224 Chassis Intrusion Physical Security Violation Information Event Cleared 262400 Generic Predictive Fan Failure predictive failure asserted M inor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information Traps 727 Table 27 20 BMC Traps continued
224. Traps TrapID Name Description Severity Category Cause Supported by RAC Platform 0 CodeStart SNMP agentis Information Status RAC power All initializing itself on or reset 1 Authentic Request received Critical Error SNMP All ation with an invalid request Failure community name with an invalid community name Table 27 19 Enterprise specific Traps TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1001 alertDrscTest TheRAC Information Status AtestSNMP All TrapE vent generated a trap test trap generated by event in aRAC response to a user request Traps 721 Table 27 19 Enterprise specific Traps continued TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1002 alertDrscAuth RAC M inor Error RAC login All Error Authenticati failure caused on failures by during a authenticatio time period n failure have number of exceeded a concurrent threshold logins exceed limit or permission denied 1003 alertDrscLos The RAC Critical Error RAC lost Dell ESM cannot communicati Remote communicate on with ESM Access with the Controlle baseboard r management DRAC controller HI ESM 1004 alertDrscFound TheRAC is Information Error RAC DRAC ESM communicat recovered III ing normally communicati with the on with ESM baseboard management controller ESM 1005 alertDrscPower The RAC Critical Error RAC DRAC off has detected detected a III a system
225. Traps Hardware Log Traps Hardware logs provide hardware status messages to systems management software On certain systems the hardware log is implemented as a circular queue W hen the log becomes full the oldest status messages are overwritten when new status messages are logged On some systems the log is not circular W hen thelog becomes full subsequent hardware status messages are lost Hardware log sensor messages provide status and warning information about the noncircular logs that may fill up resulting in lost status messages Table 27 13 Hardware Log Traps TrapID Description Severity Cause Hardware Log Normal 1552 Log sizeis no longer near or Information The hardware log on the at capacity specified system is no longer near or at its Log type lt L og type gt ane aE capacity usually as the result of clearing the log The log type information is provided Hardware Log Warning 1553 Log sizeis near or at capacity Warning The sizeof a hardware log Log type lt L og type gt on the specified system is near or at the capacity of the hardware log The log type information is provided Hardware Log Full 1554 Logsizeis full Error The size of a hardware log Log type lt L og type gt on the specified system is at the capacity of the hardware log The log type information is provided Traps 715 Processor Device Status Traps TheBMC on some systems reports the status of processor devices Proce
226. Type Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA 8 The memory array location is a Personal Computer M emory Card International Association PCMCIA option card memoryArrayLocationIsProprietary 9 The memory array location is a proprietary option card memoryArrayLocationIsNUBUS 10 The memory array location is a NuBus bus memoryArrayLocationIsPC98C20 11 The memory array location is a PC 98 C 20 option card memoryArrayLocationIsPC98C24 12 The memory array location is a PC 98 C 24 option card memoryArrayLocationIsPC98E 13 The memory array location is a PC 98 E option card memoryArrayLocationIsPC98LocalBus 14 The memory array location is a PC 98 L ocal bus option card memoryArrayLocationIsPC98Card 15 The memory array location is a PC 98 C ard slot option card Memory Group 383 Table 16 2 Physical Memory Array ECC Type Definitions Variable Name De 1 1PhysicalMemoryArrayECCType Data Type Integer Possible Data Values Meaning of Data Value memoryArrayECCTypelsOther 1 There is not one of the following memoryArrayECCTypelIsUnknown 2 The memory array ECC typeis unknown memoryArrayECCTypelsNone 3 The memory array ECC typeis none memoryArrayECCTypelsParity 4 The memory array ECC typeis parity memoryArrayECCTypeIsSingleBitECC 5 The m
227. TypeIsSGRAM 16 Device type is SGRAM deviceTypeIsRDRAM 17 Device type is RD RAM deviceTypeIsDDR 18 Device typeisDDR deviceTypelIsDDR2 19 Device type is DDR2 deviceTypeIsDDR2FBDIMM 20 Device type is DDR2 FB DIMM deviceTypelIsDDR3 24 Device type is DDR3 deviceTypelIsFBD2 25 Device type is FBD 2 340 Device Group Table 14 17 Memory Device Type Details Variable Name De 1 1MemoryDeviceTypeDetails Data Type Integer Possible Data Values Meaning of Data Value deviceTypeDetaillIsOther 2 The detailed device type is not one of the following deviceTypeDetailIsUnknown 4 The detailed device type is unknown deviceTypeDetaillIsFastPaged The detailed device type is fast paged 8 deviceTypeDetailIsStaticColum The detailed device type is static column n 16 deviceTypeDetailIsPseudoStati Thedetailed device type is pseudo static e sZ deviceTypeDetailIsRAMBUS 64 The detailed device type is RAM BUS deviceTypeDetailIsSynchronous The detailed device type is synchronous 128 deviceTypeDetailIsCMOS 256 The detailed device type is CMOS deviceTypeDetailIsEDO 512 The detailed device type is EDO deviceTypeDetailIsWindowDRAM The detailed device type is W indow 1024 DRAM deviceTypeDetailIsCacheDRAM The detailed device type is Cache 2048 DRAM deviceTypeDetailIsNonVolatile The detailed
228. UChassisIndex Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 1 Description Defines the index one based of the associated chassis Syntax DellC M C Powerl ndexRange Access Read only 710 Dell Remote Access Controller Out of Band Group DRsPSUIndex Name DRsPSUIndex Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 2 Description Defines the index one based of the associated CMC PSU Syntax DellCMCPSUIndexRange Access Read only DRsPSULocation Name DRsPSULocation Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 3 Description Defines the location of the CMC PSU Syntax DellString Access Read only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 4 Description Definesthe PSU Monitoring capabilities or the absence of aPSU in this location Syntax DellCMCPSUCapable Access Read only DRsPSUVoltsReading Name DRsPSUVoltsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 5 Description Defines theinstantaneousPSU Voltage reading Syntax DellPowerReading Access Read only Dell Remote Access Controller Out of BandGroup 711 DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 6 Description Defines the instantaneous PSU Current reading Syntax D ellPowerReading Access Read only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 7 Description Defines the instantaneous PSU Wattage reading Syntax D ellPowerReading Access Read only Ch
229. UUID Type Name Object ID Description uUIDchassisIndex 1 3 6 1 4 1 674 10892 1 300 20 1 1 Defines the index one based of this chassis DellObjectRange Read only uUIDIndex 1 3 6 1 4 1 674 10892 1 300 20 1 2 Defines the index of the UUID in aspecified chassis DellObjectRange Read only uUIDType 1 3 6 1 4 1 674 10892 1 300 20 1 3 Defines the type of the UUID for this chassis Chassis Information Group 85 Name uUIDType Syntax DellUUID Type Access Read only UUID Value Name uUIDValue Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 4 Description Defines the value of the UUID for this chassis Syntax Octet String SIZE 16 Access Read only POST Log Table This section defines attributes for the power on self test POST log W hen you turn on your computer the POST checks various system components before the operating system loads The POST tests the random access memory RAM the hard drives and the keyboard for example W hile the POST is running it makes a log file that system administrators can view The variables in this section also contribute to managing the POST log Name postLogTable Object ID 1 3 6 1 4 1 674 10892 1 300 30 Description Definesthe POST Log Table Syntax SEQUENCE OF PostLogTableEntry Access Not accessible POST Log Table Entry Name postLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 Description Definesthe POST Log Table entry Syntax PostL ogTableE ntry 86 Chas
230. Unsigned32BitRange Access Read only 128 Operating System Group System Resource Group The Management Information Base M IB variables presented in this section enable you to track various attributes of your system resources T his section includes System Resource Group Tables on page 129 that track variables such as the owner ports system memory interrupts and direct memory access System Resource Group Tables The following M IB tables define objects for the System Resource Group System Resource M ap Table on page 129 System Resource O wner Table on page 131 System Resource Input Output 1 0 Port Table on page 134 System Resource M emory Table on page 137 System Resource Interrupt Table on page 140 System Resource Direct Memory Access DMA Table on page 143 System Resource Map Table Name systemResourceMapTable Object ID 1 3 6 1 4 1 674 10892 1 500 10 Description Defines the System Resource M ap Table Syntax SEQUENCE OF SystemResourceM apTableE ntry Access Not accessible System Resource Group 129 System Resource Map Table Entry Name Object ID Description Syntax Access Index systemResourceMapTableEntry 1 3 6 1 4 1 674 10892 1 500 10 1 Defines the System Resource M ap Table entry SystemR esourceM apTableE ntry Not accessible systemResourceM apchassisIndex systemResourceM aplndex System Resource Map Chassis Index Name Object ID Description Syntax Access systemR
231. a TFTP server tftpRemoteFwUpdateCapable 8 Theremote access hardware supports remote firmware update using a TFTP server 514 Remote Access Group Table 20 9 Remote Access Host Settings Variable Name Del 1RemoteAccessHostSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no host settings unknown 1 The remote access hardware host settings are unknown smtpEmailEnabled 2 The remote access hardware SM TP client is enabled for sending e mail tftpRemoteF loppyEnabled 4 The remote access hardware TFTP client is enabled for remote floppy boot tftpRemoteFwUpdateEnabled 8 The remote access hardware TFTP client is enabled for remote firmware update Table 20 10 Remote Access Out Of Band Simple Network Management Protocol SNMP Capabilities Variable Name De 1 1RemoteAccessOutOfBandSNMPCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no out of band SNMP capabilities unknownCapabilities 1 The remote access hardware out of band SNMP capabilities are unknown oobSNMPAgentCapable 2 The remote access hardware has an out of band SNM P agent oobSNMPTrapsCapable 4 The remote access hardware can send out of band SNM P traps Remote Access Group 515 Table 20 11 Remote Access Out Of Band Simple Network
232. a chip connectorPortTypeIsDIP 6 The memory device port connector type is a dual in line package DIP connectorPortTypelIsZIP 7 The memory device port connector type is a ZIP ypelsAProprietaryCard 8 The memory device port connector typeisa proprietary card connectorPort connectorPortTypeIsDIMM 9 The memory device port connector type is a dual in line memory module DIMM connectorPortTypelIsTSOP 10 The memory device port connector type is a TSOP connectorPortTypeIsARowOfChips 11 The memory device port connector type is a row of chips 258 Port Group Table 13 4 Memory Device Port Connector Types continued Variable Name De 1 1MemoryDevicePortConnectorType Data Type Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM 12 The memory device port connector type is a Rambus Inline Memory M odule RIMM connectorPortTypeIsSODIMM 13 The memory device port connector type is a small outline dual in line memory module SODIMM connectorPortTypeIsSRIMM 14 The memory device port connector typeisaSRIMM Table 13 5 Monitor Port Connector Types Variable Name De 1 1MonitorPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPort TypelsOther 1 The monitor port connector type is not one of the following connectorPort ypelsUnknown
233. ableThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 14 Defines the value of the voltage probe s lower nonrecoverable threshold DellSigned32BitRange Read only Voltage Probe Probe Capabilities Name Object ID Description Syntax Access 162 voltageProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 15 Defines the probe capabilities of the voltage probe DellProbeC apabilities Read only Power Group Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 16 Description Defines the reading for a voltage probe of type voltageProbeTypel sD iscrete W hen the value for voltageProbeType is other than voltageProbeTypel sD iscrete a value is not returned for this attribute W hen the value for voltageProbeType is voltageProbeTypel sD iscrete the value returned for this attribute is the discrete reading for the probe Syntax DellVoltageD iscreteR eading Access Read only Amperage Probe Table Name amperageProbeTabl Object ID 1 3 6 1 4 1 674 10892 1 600 30 Description Defines the Amperage Probe Table Syntax SEQUENCE OF AmperageProbeT ableE ntry Access Not accessible Amperage Probe Table Entry Name Object ID Description Syntax Access Index amperageProbeTableEntry 1 3 6 1 4 1 674 10892 1 600 30 1 Defines the Amperage Probe Table entry AmperageProbeTableE ntry Not accessible amperageP robechassisl ndex amperageProbel ndex 163 Power Gr
234. ad only Memory Device Port Name Name memoryDevicePortName Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 8 Description Defines the name of the memory device port Syntax DellString Access Read only Memory Device Port BIOS Connector Type Name memoryDevicePortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 9 Description Defines the BIOS connector type of the memory device port Syntax D ellG enericPortC onnectorType Access Read only Memory Device Port Physical Memory Array Index Reference Name memoryDevicePortPhysicalMemoryArrayIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 10 Description Defines the index to the associated physical memory array Syntax DellUnsigned32BitRange Access Read only 238 Port Group Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 11 Description D efines the index one based of the Physical M emory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with if any Syntax DellU nsigned32BitR ange Access Read only Monitor Port Table Name monitorPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 50 Description Defines the M onitor Port Table Syntax IntegerM onitorPortTableE ntry Access Not accessible Monitor Port Table Entry Name monitorPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000
235. ad only PortGroup 231 Keyboard Port Status Name keyboardPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 5 Description Defines the status of the keyboard port Syntax DellStatus Access Read only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 6 Description Defines the security settings of the keyboard port Syntax DellPortSecurityState Access Read only Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 7 Description Defines the connector type of the keyboard port Syntax D ellKeyboardPortC onnectorType See Table 13 2 Access Read only Keyboard Port Name Name keyboardPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 8 Description Defines the name of the keyboard port Syntax DellString Access Read only 232 Port Group Keyboard Port BIOS Connector Type Name keyboardPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 9 Description Defines the BIOS connector type of the keyboard port Syntax D ellG enericPortC onnectorType Access Read only Processor Port Table Name processorPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 30 Description Defines the Processor Port Table Syntax IntegerProcessorPortT ableE ntry Access Not accessible Processor Port Table Entry Name processorPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 Description Defines the Proc
236. ad only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 10 Description Defines additional capabilities of the serial port Syntax D ellSerialPortC apabilitiesU nique Access Read only Serial Port Base 1 0 Address Name serialPortBaselOAddress Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 11 Description Defines the base I O address of the serial port Syntax D ellU nsigned64BitR ange Access Read only Serial Port IRO Level Name serialPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 12 Description Defines the IRQ of the serial port Syntax D ellU nsigned8BitR ange Access Read only PortGroup 251 Universal Serial Bus USB Port Table Name uSBPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 90 Description Defines the USB Port Table Syntax IntegerU SBPortTableE ntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 Description Defines the USB Port Table entry Syntax USBPortTableE ntry Access Not accessible Index uSBPortchassisIndex uSBPortl ndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only USB Port Index Name uSBPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 2 Description Defines the index of the USB ports in this
237. ad only Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 25 Description Indicates if this virtual disk is configured as C acheC ade Value 1 Yes 0 No 99 Undetermined Syntax Integer Access Read only Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 26 Description Indicates disk cache policy of the logical device Value 1 Enabled 2 Disabled 99 Undetermined Syntax Integer Access Read only Array Disk Logical Connection Table This table describes the connections between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an instance number in the appropriate M IB table for that object where all of the object properties can be found 666 Storage Management Group The following object sets up the Array Disk Logical C onnection Table Name Object ID Description Syntax Access arrayDiskLogicalConnectionTable 1 3 6 1 4 1 674 10893 1 20 140 3 Defines the array disk logical connection table SEQUENCE OF arrayDiskL ogicalC onnectionE ntry Not accessible Array Disk Logical Connection Entry Name Object ID Description Syntax Access Index arrayDiskLogicalConnectionEntry 1 3 6 1 4 1 674 10893 1 20 140 3 1 Defines the array disk logical connection table entry ArrayD iskL ogicalC onnectionE n
238. addressed security issues that exist in version 1 All SNM P systems consist of one or more managed systems that provide data through an SNMP agent to a management system The management system provides a user interface to view data from the managed systems T he management system and managed systems communicate over a network typically through U ser D atagram Protocol I nternet Protocol UD P IP The management system and a managed system communicate by means of a common data schema SNM P MIB files define the structure type and values of the SNMP data W hile M IBs can be standardized or enterprise specific most operating systems supply SNM P agents for the standard M IB I and MIB II schemas M IB I defines a base set of standard management information for systems implementing the Internet Protocol IP suite MIB I defines characteristics of the system characteristics of network interfaces and characteristics of components of the IP on the system In addition to the standard M Bs many hardware vendors have defined M I Bs that provide management data specific to their systems and peripheral devices M onitored data can be retrieved through SNMP using the Get command Typically this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve Exact details are dependent on the operating system and the development tools being used to create the management application The Get command has a
239. ageProbeLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 14 Defines the value of the amperage probe s lower nonrecoverable threshold DellSigned32BitRange Read only Amperage Probe Probe Capabilities Name Object ID Description Syntax Access amperageProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 600 30 1 15 Defines the probe capabilities of the amperage probe DellProbeC apabilities Read only Amperage Probe Discrete Reading Name Object ID Description Syntax Access amperageProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 600 30 1 16 Defines the reading for a amperage probe of type amperageProbeTypel sD iscrete W hen the value for amperageProbeType is other than amperageProbeTypel sD iscrete a value is not returned for this attribute W hen the value for amperageProbeT ype is amperageProbeTypel sD iscrete the value returned for this attribute is the discrete reading for the probe D ellAmperageD iscreteR eading See Table 9 9 Read only 168 l Power Group AC Power Switch Table Name aCPowerSwitchTable Object ID 1 3 6 1 4 1 674 10892 1 600 40 Description Defines the AC Power Switch Table Syntax SEQUENCE OF AC PowerSwitchTableE ntry Access Not accessible AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 Description Defines the AC Power Switch Table entry Syntax AC PowerSwitchTableE ntry Access Not accessible Index aC P
240. ageStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 13 Defines the status of all voltage probes in this chassis Octet String Size 1 128 Read only System State Group 55 System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 14 Description Defines the state of all current probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific current probe T he first byte returned represents the state of the first current probe the second byte returned represents the state of the second current probe and so on The bytes have the same definition type as D ellStateSettings Syntax Octet String Size 1 128 Access Read only System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 15 Description Defines the status of all amperage probes in this chassis The result is returned as a combined status value T he value has the same definition type as D ellStatus Syntax DellStatus Access Read only System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 16 Description Defines the status of all amperage probes in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the status of a specific amperage probe Th
241. ags are undefined noTeam 1 Device is not part of any team teamingEnabled 2 Teaming is enabled adapterFaultToleranceMode 4 Adapter fault tolerance teaming mode loadBalancingMode 8 Load balancing teaming mode Table 14 22 Network Device TOE Capability Flags Variable Name De 1 1NetworkDeviceTOECapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for TOE capability is not supported unknown 1 Querying for TOE capability is supported but query returned an error available 2 Device has TOE capability notAvailable 4 Device does not have TOE capability cannotBeDetermined 8 Querying for TOE capability is supported but an error prevented querying driverNotResponding 16 Querying for TOE capability is supported but driver did not respond to query 344 Device Group Table 14 23 Network Device RDMA Capability Flags Variable Name De 1 1NetworkDeviceRDMACapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for RD MA capability is not supported unknown 1 Querying for RDMA capability is supported but query returned an error available 2 Device has RDM A ca
242. ak value in Watts 125 Possible memory module event cause lt list of causes gt Specifies a list of possible causes for the memory module event for example Possible memory module event cause Single bit warning error rate exceeded Single bit error logging disabled Power Supply type lt type of power supply gt Traps Specifies the type of power supply for example Power Supply type VRM Table 27 1 Trap Description Reference continued Description Line Item Explanation Pre failure stat lt State gt was Specifies the status of the previous memory message for example Pre failure stat Failed was Previous redundancy state was lt State gt Specifies the status of the previous redundancy message for example Previous redundancy state was Lost Previous state was lt State gt Specifies the previous state of the sensor for example Previous state was OK Normal Processor sensor status lt status gt Specifies the status of the processor sensor for example Processor sensor status Configuration error Redundancy unit lt Redundancy location in chassis gt Specifies the location of the redundant power supply or cooling unit in the chassis for example Redundancy unit Fan Enclosure SD card device type lt Type of SD card device gt Specifies the type of SD card device for example SD card devic
243. al Data Group The Global Data M anagement Information Base MIB Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage M anagement SNMP agent Agent System Global Status Name agentSystemGlobalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 1 Description This entry is obsolete Use the value agentGlobalSystemStatus Syntax Integer Access Read only 556 l Storage M anagement Group Agent Last Global Status Name agentLastGlobalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 2 Description This entry is obsolete Use the value agentL astGlobalSystemStatus Syntax Integer Access Read only Agent Time Stamp Name agentTimeStamp Object ID 1 3 6 1 4 1 674 10893 1 20 110 3 Description Identifies the last time that the agent values have been updated Universal time in sec since UTC 1 1 70 Syntax Integer Access Read only Agent Get Timeout Name agentGet Timeout Object ID 1 3 6 1 4 1 674 10893 1 20 110 4 Description Indicates the suggested timeout value in milliseconds for how long the SNM P getter should wait while attempting to poll the SNM P agent Syntax Integer Access Read only Storage Management Group 557 Agent Modifiers Name agentModifiers Object ID 1 3 6 1 4 1 674 10893 1 20 110 5 Description Identifies the agent functional modifiers W hen set the modifier is active Bit definitions Bit 3 agent in debug
244. ame Access Read write COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 8 Description Defines the fair market value of this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information Lessor Name Name cooLeaseInformationLessorName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 9 Description Defines the name of the lessor of this system Syntax DellC ostofO wnershipString Access Read write 456 Cost of Ownership Group COO Schedule Number Table Name cooScheduleNumberTabl Object ID 1 3 6 1 4 1 674 10892 1 1600 60 Description Defines the COO Schedule Number Information Table Syntax SEQUENCE OF CooScheduleN umberTableE ntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 Description Defines the COO Schedule Number Information Table entry Syntax C ooScheduleN umberTableE ntry Access Not accessible Index cooScheduleN umberchassis ndex cooScheduleN umberl ndex COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Schedule Number Index Name cooScheduleNumber Index Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 2 Description Defines the index of the schedule number informa
245. ame De 11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value frontPanel 9 The firmware type is Front Panel Controller baseboardManagementController 10 The firmware type is Baseboard Management C ontroller hotPlugPCI 11 The firmware type is Hot Plug Peripheral Component Interconnect PCI Controller sensorData 12 The firmware type is Sensor Data Records peripheralBay 13 The firmware type is Peripheral Bay Backplane secondaryBackPlane 14 The firmware type is Secondary Backplane for ESM 2 systems secondaryBackP laneESM3And4 15 T he firmware type is Secondary Backplane for ESM 3 and 4 systems rac 16 The firmware type is Remote Access C ontroller iDRAC 17 T he firmware type is Integrated Dell Remote Access C ontroller unifiedServerConfigurator 19 The firmware type is U nified Server Configurator lifecycleController 20 The firmware type is Lifecycle Controller Chassis Information Group Table 6 23 Baseboard Type Variable Name De 1 1BaseBoardType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The baseboard type is unknown other 2 The baseboard type is not one of the following types serverBlade 3 The baseboard type is a server blade connectivitySwitch 4 The baseboard type is a connectivity switch systemManage
246. ame operatingSystemSPMajorVersion Object ID 1 3 6 1 4 1 674 10899 2 5 Description Defines the O perating System s Service Pack major version Syntax DisplayString Access Read only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1 3 6 1 4 1 674 10899 2 6 Description Defines the O perating System s Service Pack minor version Syntax DisplayString Access Read only Operating System Architecture Name operatingSystemArchitecture Object ID 1 3 6 1 4 1 674 10899 2 7 Description Defines the O perating System s architecture Syntax DisplayString Access Read only Inventory Collector Product Information The following objects describe the fields for the Inventory C ollector The Inventory Collector product variables are scalar objects meaning that they are not related to other Inventory Collector base M IB objects and are thus not placed in a table 680 Change M anagement Group Product ID Display Name Name Object ID Description Syntax Access product IDDisplayName 1 3 6 1 4 1 674 10899 100 1 Defines the display name of the product DisplayString Read only Product ID Description Name Object ID Description Syntax Access productIDDescription 1 3 6 1 4 1 674 10899 100 2 Provides a description of the product DisplayString Read only Product ID Vendor Name Object ID Description Syntax Access product IDVendor 1 3 6 1 4 1 674 10899 100 3 Provides na
247. ame remoteUserAdminPagerAlphaPagerlIdName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 23 Description Defines the D to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Alpha Password Name Name remot eUserAdminPagerAlphaPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 24 Description Defines the password for the alphanumeric pager for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote Access Group 493 Remote User Admin Pager Modem Init String Name Name remot eUserAdminPagerModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 25 Description Defines the initialization string to be sent to the pager modem for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Modem Port Name remot eUserAdminPagerModemPort Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 26 Description Defines the port for the pager modem for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin E Mail Address Name Name remoteUserAdminEmailAddressName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 27 Description Defines the e mail address for this remote access user Syntax DisplayString SIZE 0 63 Access Read write Remote User Admin E Mail Custom Message Name Name remot eUserAdm
248. amily is AM D Athlon XP deviceFamilyIsAMDAthlonMP 183 The processor family is AM D Athlon MP deviceFamilyIsAMDDuron 184 The processor family is AM D Duron deviceFamilyIsIntelPentiumM 185 The processor family is Intel Pentium M deviceFamilyIsIntelCeleronD 186 The processor family is Intel C eleron D deviceFamilyIsIntelPentiumD 187 The processor family is Intel Pentium D deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium eme 188 Processor Extreme Edition deviceFamilyIsIntelCoreSolo The processor family is Intel C ore Solo 189 processor deviceFamilyIsIntelCore2 190 The processor family is Intel Core 2 processor deviceFamilyIsIntelCore2Duo The processor family is Intel C ore 2 191 D uo processor deviceFamilyIsIntelCore2Solo The processor family is Intel C ore2 192 Solo processor deviceFamilyIsIntelCore2Extrem The processor family is Intel C ore2 e 193 Extreme processor deviceFamilyIsIntelCore2Quad The processor family is Intel C ore2 194 Quad processor Device Group 331 Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelCore2Extrem The processor family is Intel C ore2 eMobile 195 Extreme mobile processor deviceFamilyIsIntelCore2DuoMob The proc
249. an SNMP table The table contains variables that must occur in a definite sequence In the example table the defined variables are UUID Chassis Index UUID Index UUID Type and UUID Value Example SNMP Table UUID Table These objects comprise the Server Administrator definitions for the UUID Name uUIDTable ObjectID 1 3 6 1 4 1 674 10892 1 300 20 Description Definesthe UUID table Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Introduction 29 UUID Table Entry Name uUIDTableEntry ObjectID 1 3 6 1 4 1 674 10892 1 300 20 1 Description Definesthe UUID table entry Syntax UUIDTableE ntry Access Not accessible Index uUID Index uUID chassis ndex UUID Chassis Index Name uUIDchassisIndex ObjectID 1 3 6 1 4 1 674 10892 1 300 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only UUID Index Name uUIDIndex ObjectID 1 3 6 1 4 1 674 10892 1 300 20 1 2 Description Defines the index of the UUID in aspecified chassis Syntax DellObjectRange Access Read only UUID Type Name uUIDType ObjectID 1 3 6 1 4 1 674 10892 1 300 20 1 3 Description Defines the type of the UUID for this chassis Syntax DellUUIDType Access Read only 30 Introduction UUID Value Name uUIDValue ObjectID 1 3 6 1 4 1 674 10892 1 300 20 1 4 Description Defines the value of the UUID for this chassis Syntax Octet String SIZ E 16 Access Read only Reference Guid
250. and additional information about the power supply event are provided Memory Device Traps M emory device messages provide status and warning information for memory modules present in a particular system M emory devices determine health status by counting the number of ECC memory corrections K NOTE A value of failure or non recoverable does not indicate a system failure or loss of data but rather that the specified system exceeded the specified ECC correction threshold Although the system continues to function you should perform system maintenance as described in Table 27 10 Table 27 10 Memory Device Messages TrapID Description Severity Cause 1403 M emory device location lt Location in chassis gt Possible memory module event cause lt list of causes gt Memory device status lt status gt Warning A memory device correction rate exceeded an acceptable value The memory device status and location are provided Traps m Table 27 10 Memory Device Messages continued TrapID Description Severity Cause 1404 Memory device status lt Status gt Error M emory device location lt Location in chassis gt Possible memory module event cause lt list of causes gt A memory device correction rate exceeded an acceptable value a memory spare bank was activated or a Uncorrectable M emory Event occurred T he system continues to function normally except for a Uncor
251. ange Access Read only COO Support Information State Name cooSupportiInformationState Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 3 Description Defines the support information state for this system Syntax DellStateSettings Access Read only COO Support Information Is Outsourced Name cooSupportiInformationIsOut sourced Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 4 Description Specifies whether the support for this system is outsourced or not Syntax DellBoolean Access Read write CostofOwnership Group 465 COO Support Information Type Name cooSupportInformationType Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 5 Description Defines the type of component system or network problem that occurred Syntax DellUnsigned32BitRange Access Read write COO Support Information Help Desk Name Name cooSupportiInformationHelpDeskName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 6 Description Defines the help desk information provided Syntax DellC ostofO wnershipString Access Read write COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 7 Description Defines the method used to fix the problem Syntax DellC ostofO wnershipString Access Read write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system Name cooTroubleTicketTable Object ID 1 3 6 1 4
252. ange Read only USB Control Index Name Object ID Description Syntax Access usbControliIndex 1 3 6 1 4 1 674 10892 1 1400 50 1 2 Defines the index one based of the USB in this chassis DellO bjectRange Read only USB Control Capabilities Name Object ID Description Syntax Access usbControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 50 1 3 Defines the capabilities of the USB DellStateC apabilities Read only BIOS Setup Control Group 407 USB Control Settings Name usbControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 4 Description Defines the control settings for the USB Syntax DellStateSettings Access Read only USB Control Status Name usbControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 5 Description Defines the status of the USB Syntax DellStatus Access Read only USB Control Name Name usbControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 6 Description Defines the setup BIOS name of the USB Syntax DellString Access Read only IDE Control Table These objects enable you to track the attributes of Integrated D evice Electronics IDE controller cards in your system Name ideControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 60 Description Defines the DE Control Table Syntax IdeC ontrolTableE ntry Access Not accessible 408 BIOS Setup Control Group IDE Control Table Entry Name Object ID Description Syntax Access Index ideControlTableEntry
253. angeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 4 Description Defines the timestamp of the most recent Redundancy status change Syntax TimeTicks Access Read only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 5 Description Defines the timestamp of the most recent power health status change Syntax TimeTicks Access Read only DRsFanChangeTime Name DRsFanChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 6 Description Defines the timestamp of the most recent fan health status change Syntax TimeTicks Access Read only Dell Remote Access Controller Out of BandGroup 703 DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 7 Description Defines the timestamp of the most recent blade health status change Syntax TimeTicks Access Read only DRsTempChangeTime Name DRsTempChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 8 Description Defines the timestamp of the most recent temperature sensor health status change Syntax TimeTicks Access Read only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 9 Description Defines the timestamp of the most recent CMC health status change Syntax TimeTicks Access Read only 704 Dell Remote Access Controller Out of Band Group Chassis Power The following M IB tables provide information on the chassis management controller table entry DRsCMC Power Table Name DRsCMCPowerTable
254. apable 64 Setup BIOS is capable of autoconfiguring all serial ports BIOS Setup Control Group 425 Table 17 15 Serial Port Control Capabilities continued Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value comlOrCom3CapableAndAuto ConfigCapable 86 Setup BIOS has enabled autoconfiguration of COM 1and COM 3 serial ports com20rCom4CapableAndAuto ConfigCapable 106 Setup BIOS has enabled autoconfiguration of COM2 and COM 4 serial ports allcomCapable 126 Setup BIOS is capable of enabling or autoconfiguring all serial ports Table 17 16 Serial Port Control Settings Variable Name De11SerialPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Serial port state is unknown enabled 2 Setup BIOS has enabled the serial port coml 4 Setup BIOS has selected serial port 1 comlEnabled 6 Setup BIOS has enabled serial port 1 com2 8 Setup BIOS has selected serial port 2 com2Enabled 10 Setup BIOS has enabled serial port 2 com3 16 Setup BIOS has selected serial port 3 com3Enabled 18 Setup BIOS has enabled serial port 3 com4 32 Setup BIOS has selected serial port 4 com4Enabled 34 Setup BIOS has enabled serial port 4 comPortsAutoConfig 64 Setup BIOS has selected
255. application on the management system can wait for traps and act on them when received Introduction 37 For alist of traps supported by the Server Administrator Instrumentation Service see Instrumentation Traps on page 696 For information on Server Administrator Storage M anagement traps see Storage M anagement Alert Reference on page 753 For alist of traps supported by the Remote Access C ontroller see RAC Traps on page 742 BMC Traps on page 747 and iD RAC 7 Traps on page 767 38 Introduction Dell OpenManage Server Administrator Version 7 0 This section contains information added or updated for the current release What s New in This Release Server Administrator Instrumentation MIB e Added MIB table BIOS Setting Table to the BIOS Setup Control Group e Added values iD RAC 7 16 and iDRAC 7M odular 17 to the DellM anagementC ontrollerType enumeration iDRAC7 MIB e Added iDRAC7 MIB which provides management data that allows you to monitor devices and software on a system via an out of band connection to the iD RAC 7 of a system e Added RAC Information Group e Added Chassis Information Group e Added System Information Group e Added Status Group For alist of Platforms Operating Systems Browsers support added and deprecated refer to the D ell O penM anage Server Administrator Version 7 0 User s Guide and D ell Systems Software Support M atrix Version 7 0 at support dell com manuals Update
256. are Variable Values This section includes definitions of server administrator specific variable values used in this section Table 4 1 Systems Management Software Supported Standards Variable Name SMSSupportedTypes Data Type Integer Possible Data Values Meaning of Data Value supportsSNMP 1 This system supports SN M P support sDMI 2 This system supports DMI supportsSNMPandDMI 3 This system supports SNM P and DMI support sCIMOM 4 This system supports CIM supportsSNMPandCIMOM 5 This system supports SNM P and CIM Systems M anagement Software Group 47 48 Table 4 2 Systems Management Software Feature Flags Variable Name SMSFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems M anagement Software features are not enabled webOneToOneManagementPreferred 1 Theweb 1 1 management preferred feature is enabled Table 4 3 Systems Management Software SNMP Agent Feature Flags Variable Name SMSSNMPAgentFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems M anagement Software SNMP agent features are not enabled supportsSparseTables 1 The SNMP agent supports sparse tables Systems M anagement Software Group System State Group The M anagement Information Base M IB variables presented in this section enable you to track various attributes that describe t
257. arning 2186 Power supply has System Power Supply M inor detected a warning Health Power Supply Failure 2185 Power supply has System Power Supply Critical detected a failure Health 756 iDRAC7 MIB Table 29 15 Power Supply Absent Trap TrapID Description Category SubCategory Severity Power Supply Absent 2465 Powersupply is absent System PSU Absent Critical Health Table 29 16 Power Usage Traps TrapID Description Category SubCategory Severity Power Usage Information 2275 System performance System Power Usage Informational restored Health Power Usage Warning 2274 System performance System Power Usage Minor degraded Health Power Usage Failure 2273 The system halted System Power Usage Critical because system power Health exceeds capacity or the system performance degraded because power draw exceeds the power threshold Table 29 17 Redundancy Traps TrapID Description Category SubCategory Severity Redundancy Information 2475 Redundancy System Redundancy Informational information Health Redundancy Degraded 2474 Redundancy is degraded System Redundancy Minor Health Redundancy Lost 2473 Redundancy is lost System Redundancy Critical Health iDRAC7MIB 757 Table 29 18 Integrated Dual SD Module Traps TrapID Description Category SubCategory Severity Integrated Dual SD Modulelnformation 2211 Integrated Dual SD System IDSDM Informational M odule informatio
258. aseboard Feature Flags Name baseBoardFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 6 Description Defines the features of the baseboard Syntax D ellBaseBoardF eatureF lags Access Read only Baseboard Type Name baseBoardType Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 7 Description Defines the type of the baseboard Syntax DellBaseBoardType Access Read only Chassis InformationGroup 105 Baseboard Type Name Name baseBoardTypeName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 8 Description Defines the name of the type of baseboard Syntax DellString Access Read only Baseboard Location Name Name baseBoardLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 9 Description Defines the location name of the baseboard Syntax DellString Access Read only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 10 Description Defines the baseboard manufacturer s name Syntax DellString Access Read only Baseboard Product Name Name baseBoardProductName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 11 Description Defines the baseboard product s name Syntax DellString Access Read only 106 Chassis Information Group Baseboard Version Name Name baseBoardVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 12 Description Defines the baseboard version name Syntax DellString Access Read only Baseboard Service Tag Name Name baseBoardServiceTagNam Obj
259. assis Alerts The following M IB tables provide information on the chassis management controller alerts DRsCASubSystem Name DrsCASubSystem Object ID 1 3 6 1 4 1 674 10892 2 20 10 1 Description Defines the Sub System Name of the CMC Alert Syntax DellString Access Read only 712 Dell Remote Access Controller Out of Band Group DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 20 10 2 Description Defines the Current Status of the Alerting Sub System Syntax DellStatus Access Read only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 20 10 3 Description Defines the Previous Status of the Alerting Sub System Syntax DellStatus Access Read only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1 3 6 1 4 1 674 10892 2 20 10 4 Description Defines the timestamp of M ost Recent C hange of the Alerting Sub System Syntax TimeTicks Access Read only DrsCAMessage Name DrsCAMessage Object ID 1 3 6 1 4 1 674 10892 2 20 10 5 Description DefinestheCSSD message of the CMC Alert Syntax DellString Access Read only Dell Remote Access Controller Out of BandGroup 713 Legacy Alerting The following M IB tables provide information on the RAC legacy alerting DRsAlertSystem Name DRsAlertSystem Object ID 1 3 6 1 4 1 674 10892 2 5000 10 1 Description Name of the system generating the alert Syntax Octet String SIZE 0 255 Access Read only DRsAlertTableIndex
260. at are possible for each port Port Group Tables The following M IB tables define objects in the Port Group e Pointing Port Table on page 227 Keyboard Port Table on page 230 Processor Port Table on page 233 e Memory Device Port Table on page 236 Monitor Port Table on page 239 Small Computer System Interface SCSI Port Table on page 242 e Parallel Port Table on page 244 Serial Port Table on page 248 Universal Serial Bus USB Port Table on page 252 Pointing Port Table Name pointingPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 10 Description Defines the Pointing Port Table Syntax IntegerPointingPortTableE ntry Access Not accessible PortGroup 227 Pointing Port Table Entry Name pointingPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 Description Defines the Pointing Port Table entry Syntax PointingPortT able ntry Access Not accessible Index pointingPortchassisIndex pointingPortl ndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Pointing Port Index Name pointingPortIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 2 Description Defines the index of the pointing ports in this chassis Syntax DellO bjectRange Access Read only Pointing Port State Capabilities Name pointingPortStateCapabilities O
261. ata deviceTypeIsUnified 5 System cache type is both instruction and data 334 Device Group Table 14 8 Cache Device Level Variable Name De 1 1CacheDeviceLevel Data Type Integer Possible Data Values Meaning of Data Value deviceLevelIsOther 1 Device level is not one of the following deviceLevelIsUnknown 2 Device level is unknown deviceLevellIsPrimary 3 Device level is primary deviceLevellIsSecondary 4 Device level is secondary deviceLevellIsTertiary 5 Device level is tertiary Table 14 9 Cache Device Write Policy Variable Name De 1 1CacheDeviceWritePolicy Data Type Integer Possible Data Values Meaning of Data Value deviceWritePolicylIsOther 1 Device write policy is not one of the following deviceWritePolicyIsUnknown 2 Device write policy is unknown deviceWritePolicyIsWriteBack 3 Device write policy is write back deviceWritePolicyIsWriteThrough 4 Device write policy is write through deviceWritePolicyIsVariesByAddress 5 Device write policy varies by address deviceWritePolicyIsDeterminedByI0 6 Device write policy is determined by I O query DeviceGroup 335 Table 14 10 Cache Device Status State Variable Name De 1 1CacheDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 Device state is not one of the following unknown 2 Device state i
262. ata Type De11Unsigned64BitRange Octet String SIZE 8 The DellD ate definition is required because SN M P V1 does not support 64 bit ranges The information sent back by this subagent has the most significant byte of the information as the first byte For example the hex address 0x1029384754657687 is sent as hex 0001 0000 0010 1001 0011 1000 0100 0111 Bytel Byte2 Byte3 Byte4 Standard Data Type Definitions 793 Full Dates Variable Name De 1 1DateName Data Type DisplayString DisplayString SIZE 25 Full dates are defined in the ASCII format yyyyM M ddhhmmss uuuuuu fff or yyyyM M ddhhmmss uuuuuu fff where yyyy is the year MM isthe month dd is the day hh are the hours mm are the minutes and ss are the seconds uuuuuu is the number of microseconds and fff or fff is the offset from UTC in minutes For example Friday October 31 2001 at 6 05 19 PM CST would be represented as 20011031180519 000000 360 The values are zero padded and if a valid value for a field is not deliverable each character in the field is replaced with an asterisk character 794 Standard Data Type Definitions SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol SNM P covering the first four groups of the Instrumentation management information base M IB sample output from the Simple Network M anagement Protocol SNM P covers the first four groups of the Instrumentation managem
263. ated to rebuilding failed array disks Syntax Integer Access Read only Controller Firmware Version Name controllerFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 8 Description Identifies the controller s current firmware version Syntax DisplayString Access Read only Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 9 Description Identifies the controller s current amount of cache memory in megabytes If this size is 0 it is less than a megabyte Syntax Integer Access Read only 566 l Storage M anagement Group Controller Cache Size in Bytes Name Object ID Description Syntax Access controllerCacheSizeInBytes 1 3 6 1 4 1 674 10893 1 20 130 1 1 10 Identifies the controller s current amount of cache memory that is less than amegabyte This combined with the controllerC acheSizel nM B is the total amount of memory Integer Read only Controller Physical Device Count Name Object ID Description Syntax Access controllerPhysicalDeviceCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 11 Identifies the number of physical devices on the controller channel including both disks and the controller Integer Read only Controller Logical Device Count Name Object ID Description Syntax Access controllerLogicalDeviceCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 12 Identifies the number of virtual disks on the controller Integer
264. ating System State Settings Name Object ID Description Syntax Access operatingSystemStateSettings 1 3 6 1 4 1 674 10892 1 400 10 1 3 Defines the state of the operating system DellStateSettings Read write Operating System Status Name Object ID Description Syntax Access operatingSystemStatus 1 3 6 1 4 1 674 10892 1 400 10 1 4 Defines the status of the operating system DellStatus Read only 124 Operating System Group Operating System Is Primary Name Object ID Description Syntax Access operatingSystemIsPrimary 1 3 6 1 4 1 674 10892 1 400 10 1 5 Specifies whether this operating system is the primary operating system DellBoolean Read only Operating System Name Name Object ID Description Syntax Access operatingSystemOperatingSystemName 1 3 6 1 4 1 674 10892 1 400 10 1 6 Defines the name of the operating system running on the system DisplayString SIZE 0 255 Read only Operating System Version Name Name Object ID Description Syntax Access operatingSystemOperatingSystemVersionName 1 3 6 1 4 1 674 10892 1 400 10 1 7 Defines the version of the operating system running on the system DisplayString SIZE 0 255 Read only Operating System Memory Table Name Object ID Description Syntax Access operatingSystemMemoryTable 1 3 6 1 4 1 674 10892 1 400 20 Defines the Operating System M emory Table SEQUENCE OF OperatingSystemM emoryTableE ntry Not ac
265. autoconfiguration of serial ports enabledAndAutoConfig 66 Setup BIOS has enabled autoconfiguration of serial ports 426 BIOS Setup Control Group Table 17 17 IDE Control Capabilities Variable Name De11ideControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 IDE control capabilities are unknown ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable 2 enable capable Table 17 18 Diskette Control Settings Variable Name De11DisketteControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Diskette control state is unknown disketteControlAutoConfigEnabled Diskette control is set as OrEnabled 2 autoconfigurable or enabled Table 17 19 Network Interface Control Capabilities Variable Name DellNetworkInterfaceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Unknown setup BIOS network interface capabilities enableCapable 2 Setup BIOS is capable of enabling the network interface enableWithoutPXECapable 4 Setup BIOS is capable of enabling the NIF without Pre boot eXecution Environment PXE BIOS Setup Control Group 427 Table 17 20 Network Interface Control Settings Variable Name De 1 1NetworkInterfaceControlSettingsUnique Data Type Integer Possible
266. ayed Syntax Integer Access Read only Storage Management Group 653 Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the controller Table The following object sets up the Battery C onnection Table Name batteryConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 Description Defines the battery connection table Syntax SEQUENCE OF BatteryC onnectionEntry Access Not accessible Battery Connection Entry Name batteryConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 Description Defines the battery connection table entry Syntax BatteryC onnectionEntry Access BatteryC onnectionEntry Index BatteryC onnectionN umber Battery Connection Number Name batteryConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 1 Description Identifies the instance number of the battery connection entry Syntax Integer Access Read only 654 Storage Management Group Battery Connection Battery Name Name Object ID Description Syntax Access batteryConnectionBatteryName 1 3 6 1 4 1 674 10893 1 20 130 16 1 2 Identifies the name of the battery in this connection as represented in Storage M anagement DisplayString Read only Battery Connection Battery Number Name Object ID Description Syntax Access batteryConnection
267. be type is a core volt probe voltageProbeTypeIsFLEA 11 The voltage probe type isa FLEA standby volt probe voltageProbeTypelIsBattery 12 The voltage probe type is a battery volt probe voltageProbeTypeIsTerminator 13 The voltage probe type is a SC SI termination volt probe voltageProbeTypelIs2Point5Volt 14 The voltage probe type is a 2 5 V probe voltageProbeTypeIsGTL 15 The voltage probe type is a ground termination logic GTL probe voltageProbeTypelIsDiscrete 16 The voltage probe type is a voltage probe with discrete reading Table 9 7 Voltage Probe Discrete Reading Variable Name De11VoltageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value voltageIsGood 1 The voltage probe discrete reading is good voltageIsBad 2 The voltage probe discrete reading is bad 190 Power Group Table 9 8 Amperage Probe Definitions Variable Name Del 1AmperageTyp Data Type Integer Possible Data Values Meaning of Data Value amperageProbeTypelsOther 1 The amperage probe type is not one of the following amperageProbeTypelsUnknown 2 The amperage probe type is unknown not known or not monitored amperageProbeTypelIsi1Point5Volt 3 The amperage probe type is a 1 5 ampere A probe amperageProbeTypels3Point3volt 4 The amperage probe typeisa 3 3 A p
268. bilities Variable Name De 1 1RemoteAccessLANCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no LAN capabilities unknownCapabilities 1 The remote access hardware LAN capabilities are unknown nicCapable 2 The remote access hardware has a network interface controller NIC nicDHCPCapable 4 The remote access hardware NIC can use DHCP to obtain an IP address Remote Access Group 513 Table 20 7 Remote Access LAN Settings Variable Name De 1 1RemoteAccessLANSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no LAN settings unknown 1 The remote access hardware LAN settings are unknown nicEnabled 2 The remote access hardware NIC is enabled nicDHCPEnabled 4 The remote access hardware NIC uses DHCP to obtain an IP address Table 20 8 Remote Access Host Capabilities Variable Name De 1 1RemoteAccessHostCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no host capabilities unknownCapabilities 1 The remote access hardware host capabilities are unknown smtpEmailCapable 2 The remote access hardware supports sending e mail using SM TP tftpRemoteFloppyCapable 4 The remote access hardware supports remote floppy boot using
269. bject ID Description Syntax Access bmcSerialiInterfaceStatus 1 3 6 1 4 1 674 10892 1 1900 20 1 6 Defines the status of the BM C serial interface DellStatus Read only BMC Serial Interface Channel Number Name Object ID Description Syntax Access bmcSerialInterfaceChannelNumber 1 3 6 1 4 1 674 10892 1 1900 20 1 7 Defines the BMC channel number of the BMC serial interface DellU nsigned8BitRange Read only 537 Baseboard Management Controller Group BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 8 Description Defines the connection mode capabilities of the BMC serial interface Syntax DellBM C SerialC onnectionM odeC apabilities Access Read only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 9 Description Defines the connection mode settings of the BM C serial interface Syntax DellBM C SerialC onnectionM odeSettings Access Read only BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 10 Description Defines the flow control type of the BMC serial interface Syntax DellBM C SerialF lowC ontrolType Access Read only BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 11 Description Defines the bit
270. bject ID 1 3 6 1 4 1 674 10892 1 1000 10 3 Description Defines the capabilities of the pointing port Syntax D ellStateC apabilities Access Read only 228 Port Group Pointing Port State Settings Name Object ID Description Syntax Access pointingPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 10 4 Defines the state and settings of the pointing port DellStateSettings Read write Pointing Port Status Name Object ID Description Syntax Access pointingPortStatus 1 3 6 1 4 1 674 10892 1 1000 10 5 Defines the status of the pointing port DellStatus Read only Pointing Port Security State Name Object ID Description Syntax Access pointingPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 10 6 Defines the security settings of the pointing port D ellPortSecurityState Read only Pointing Port Connector Type Name Object ID Description Syntax Access pointingPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 10 7 Defines the connector type of the pointing port DellPointingPortC onnectorType See Table 13 1 Read only PortGroup 229 Pointing Port Name Name Object ID Description Syntax Access pointingPortName 1 3 6 1 4 1 674 10892 1 1000 10 8 Defines the name of the pointing port DellString Read only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 10 9 Description Defines the basic input output system BIOS connector type
271. bject ID 1 3 6 1 4 1 674 10892 1 1300 20 1 7 Description Defines the physical starting address in KB of the memory array mapped address Syntax DellUnsigned64BitRange Access Read only Physical Memory Array Mapped Ending Address Name physicalMemoryArrayMappedEndingAddress Object ID 1 3 6 1 4 1 674 10892 1 1300 20 1 8 Description Defines the physical ending address in KB of the memory array mapped address Syntax DellUnsigned64BitRange Access Read only 370 l M emory Group Physical Memory Array Mapped Partition Width Name Object ID Description Syntax Access physicalMemoryArrayMappedPartitionWidth 1 3 6 1 4 1 674 10892 1 1300 20 1 9 Defines the number of memory devices that form a single row in the memory array mapped address A zero 0 indicates that the number is unknown DellU nsigned32BitRange Read only Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up for example which redundant memory types are supported and whether redundant memory is active The following object sets up the Physical M emory C onfiguration Table Name Object ID Description Syntax Access physicalMemoryConfigTable 1 3 6 1 4 1 674 10892 1 1300 30 Defines the Physical Memory Configuration Table SEQUENCE OF PhysicalM emoryC onfigTableE ntry Not accessible Physical Memory Configuration Table Entry Name Object ID Description Syntax Access Index phys
272. ble and lowO rhighSpeedC apable Introduction 31 Section Organization Sections in this reference guide are based on the Server Administrator M Bs so the complexity of each section depends on the complexity of each MIB group The first section provides a high level introduction to the MIB group If the group is defined by one or more tables the second section lists these tables The third section documents the variables that comprise the group and if applicable the variables that comprise the tables T he fourth section contains definitions for any Server Administrator specific variables that are used in the section The following example shows the typical content of these four sections 1 BIOS Setup Control Group This section explains the purpose of the MIB group and summarizes the major features of the component groups 2 BIOS Group Tables If there is more than one SNMP table for a group this section lists all of the tables For this BIOS group example there are eight tables listed In each section double clicking any table on the list takes you to that table BIOS Setup Control Table SCSI Control Table Parallel Port C ontrol Table Serial Port C ontrol Table USB Control Table IDE Control Table Diskette C ontrol Table Network Interface C ontrol Table 3 Variables that make up each table in the group This section documents the variables for the eight tables that comprise the BIOS group 32 Introduction
273. ble 8 2 Resource Owner Interface Type Variable Name De 1 1ResourceOwnerInterfaceTyp Data Type Integer Possible Data Values Meaning of Data Value typelsOther 1 The interface type is not one of the following typelIsUnknown 2 The interface type is unknown typeIsInternal 3 The interface type is internal typeIsISA 4 The interface type is an Industry Standard Architecture ISA bus 146 l System Resource Group Table 8 2 Resource Owner Interface Type continued Variable Name De 1 1ResourceOwnerInterfaceTyp Data Type Integer Possible Data Values Meaning of Data Value typeIsEISA 5 Theinterface type is an Extended Industry Standard Architecture EISA bus typeIsMCA 6 The interface type is a microchannel architecture MCA bus typeIsTurboChannel 7 The interface type is a turbo channel bus Table 8 3 Resource Share Disposition Variable Name De 1 1ResourceShareDisposition Data Type Integer Possible Data Values Meaning of Data Value shareIsOther 1 The share disposition isnot one of the following shareIsUnknown 2 The share disposition is unknown not known or not monitored shareIsDeviceExclusive 3 The share disposition is device exclusive shareIsDriverExclusive 4 The share disposition is driver exclusive shareIsShared 5 The share disposition is shared Table 8 4 Resource Memory Flags Variable Na
274. byte returned represents the status of the first AC power cord the second byte returned represents the status of the second AC power cord and so on Octet String SIZE 1 128 Read only System State Group 63 System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 38 Description Defines the state of all redundant memory units in this chassis The results are returned as a binary octet string each byte of the octet string represents the state of the specific object The first byte returned represents the state of the first object and so on T he bytes have the same definition type as D ellStateSettings Syntax Octet String Size 1 128 Access Read only System State Redundant Memory Unit Status Redundancy Name systemStateRedundantMemoryUnitStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 39 Description Defines the overall redundancy status for redundant memory Syntax DellStatusR edundancy Access Read only System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 40 Description Defines the status of all redundant memory units in this chassis The results are returned as a binary octet string each byte of the octet string represents the status of the specific object T he first byte returned represents the status of the first object and so on
275. capabilities Table 18 2 LRA Thermal Shutdown Capabilities Unique Variable Name De 11 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value none 0 TheLRA has no thermal shutdown capabilities Unknown capabilities 1 TheLRA s thermal shutdown capabilities are unknown enableCapable 2 TheLRA can be disabled offline a binary 0 value or enabled online a binary 1 value warningCapable 4 TheLRA can carry out chassis determined action s when a warning condition is detected enableOnWarningCapable 6 The LRA enables activation of chassis determined action s when a warning condition is detected failureCapable 8 TheLRA can carry out chassis determined action s when a failure condition is detected LocalResponseAgentGroup 435 Table 18 2 LRA Thermal Shutdown Capabilities Unique continued Variable Name De 1 1 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value enableOnFailureCapable 10 TheLRA enables activation of chassis determined action s when a failure condition is detected enableOnWarningOrFailure TheLRA enables activation of chassis Capable 14 determined action s when either afailureor a warning condition is detected Table 18 3 Local Response Agent Settings Unique Variable Name De 1 1 LocalResponseAgentSettingsUnique
276. cation previous state and battery sensor status are provided A battery sensor in the specified system detected that a battery has failed or is absent The sensor location chassis location previous state and battery sensor status are provided Traps 719 SD Card Device Traps On systems where the BM C reports the status of SD card devices the SD card device traps provide status and error information Table 27 17 SD Card Device Traps TrapID Description Severity Cause SD Card Device Failure 1754 SD card device detected a failure Critical An SD card device sensor Sensor Location lt Location in in the specified system chassis gt detected an error The sensor location chassis location previous state and SD card device type Previous state was lt State gt are provided The SD card i state is provided if a SD pete S SPa DERE card is present in the SD card device SD card state lt State of SD card gt Chassis Location lt N ame of chassis gt 720 Traps RAC Traps This section describes the traps that are generated by the SNM P agent of the Remote Access Controller RAC All of the enterprise specific traps documented in this section belong to the M IB enterprise identified by OID 1 3 6 1 4 1 674 10892 2 and are sent with all of the trap variables documented in the section Traps on page 689 T he trap variables are sent in the order in which they are listed Table 27 18 Generic
277. ccess functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the version of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Control Capabilities Name remoteAccessControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 10 Description Defines the control capabilities of the remote access hardware Syntax DellRemoteAccessC ontrolC apabilities See Table 20 2 Access Read only 480 Remote Access Group Remote Access Control Settings Name remoteAccessControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 11 Description Defines the control settings of the remote access hardware Syntax DellRemoteAccessC ontrolSettings See Table 20 3 Access Read write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 12 Description Defines the monitor capabilities of the remote access hardware Syntax DellRemoteAccessM onitorC apabilities See Table 20 4 Access Read only Remote Access Monitor Settings Name remoteAccessMonitorSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 13 Description Defines the monitor settings of the remote access hardware Syntax DellRemoteAccessM onitorSettings See Table 20 5 Access Read write
278. ccess Personal Computer Memory Card International Association PCMCIA Info Name Name Object ID Description Syntax Access remoteAccessPCMCIAInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Defines the information for the PCM CIA device used by the remote access hardware DisplayString SIZE 0 63 Read only Remote Access Miscellaneous Information Name Name Object ID Description Syntax Access remoteAccessMiscInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Defines the miscellaneous information for the remote access hardware DisplayString SIZE 0 63 Read write Remote Access Group 485 Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote acces
279. ccess Read write COO Trouble Ticket Number Name Name cooTroubleTicketNumberNam Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 5 Description Defines the trouble ticket number for this system Syntax DellC ostofO wnershipString Access Read write Cost of Ownership Variable Values This section includes definitions for server administrator specific variable values used in this section Table 19 1 COO Ownership Codes Variable Name Del 1CooOwnershipCodes Data Type Integer Possible Data Values Meaning of Data Value other 1 The ownership code is not one of following unknown 2 The ownership code is unknown owned 3 The ownership code is owned leased 4 The ownership code is leased rented 5 The ownership code is rented of fOfLease 6 The ownership code is off of lease transfer 7 The ownership code is transfer 468 Cost of Ownership Group Table 19 2 COO Hour Day Duration Type Variable Name Del 1CooHourDayDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown hours 2 Duration time type isin hours days 3 Duration time type is in days Table 19 3 COO Day Month Duration Type Variable Name Del 1CooDayMonthDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown days 3 Duration time type is in days mont
280. ceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypeIsATouchPad 7 Device type is a touch pad Table 14 2 Processor Device Status State Variable Name De 1 1ProcessorDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 Processor device type is not one of the following unknown 2 Device type is unknown enabled 3 Device is enabled userDisabled 4 Device is disabled by the user biosDisabled 5 Device has its BIOS disabled idle 6 Device is idle Table 14 3 Processor Device Status Reading Variable Name DellProcessorDeviceStatusReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value internalError 1 T he processor experienced an internal error thermalTrip 2 T he processor experienced a thermal trip configurationError 32 The processor experienced a configuration error processorPresent 128 The processor is present Device Group 321 Table 14 3 Processor Device Status Reading continued Variable Name De11ProcessorDeviceStatusReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value processorDisabled 256 The processor is disabled terminatorPresent 512 Theterminator is Prese
281. cessible Operating System Group 125 Operating System Memory Table Entry Name Object ID Description Syntax Access Index operatingSystemTableEntry 1 3 6 1 4 1 674 10892 1 400 20 1 Defines the Operating System M emory Table entry OperatingSystemM emoryTableEntry Not accessible operatingSystemM emorychassis ndex Operating System Memory Chassis Index Name Object ID Description Syntax Access operatingSystemMemorychassisIndex 1 3 6 1 4 1 674 10892 1 400 20 1 1 Defines the index one based of this chassis DellO bjectRange Read only Operating System Memory State Capabilities Name Object ID Description Syntax Access operatingSystemMemoryStateCapabilities 1 3 6 1 4 1 674 10892 1 400 20 1 2 Defines the capabilities of the operating system memory DellStateC apabilities Read only Operating System Memory State Settings Name Object ID Description Syntax Access 126 operatingSystemMemoryStateSettings 1 3 6 1 4 1 674 10892 1 400 20 1 3 Defines the state and allows the setting of the operating system memory DellStateSettings Read write Operating System Group Operating System Memory Status Name Object ID Description Syntax Access operatingSystemMemoryStatus 1 3 6 1 4 1 674 10892 1 400 20 1 4 Defines the status of the operating system memory DellStatus Read only Operating System Memory Total Physical Size Name Object ID Description Syntax Access o
282. cessor Device Status Table Name Object ID Description Syntax Access processorDeviceStatusTable 1 3 6 1 4 1 674 10892 1 1100 32 Defines the Processor D evice Status Table SEQUENCE OF ProcessorD eviceStatusT ableE ntry Not accessible Processor Device Status Table Entry Name Object ID Description Syntax Access Index processorDeviceStatusTableEntry 1 3 6 1 4 1 674 10892 1 1100 32 1 Defines the Processor D evice Status Table Entry ProcessorD eviceStatusTableE ntry Not accessible processorD eviceStatusC hassisl ndex processorD eviceStatusl ndex Processor Device Status Chassis Index Name Object ID Description Syntax Access processorDeviceStatusChassisIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 1 Defines the index one based of the associated chassis DellO bjectRange Read only DeviceGroup 275 Processor Device Status Index Name Object ID Description Syntax Access processorDeviceStatusIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 2 Defines the index one based of the processor device status probe DellO bjectRange Read only Processor Device Status State Capabilities Name Object ID Description Syntax Access processorDeviceStatusStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 32 1 3 Defines the state capabilities of the processor device status probe DellStateC apabilities Read only Processor Device Status State Settings Name Object ID Description Syntax Access
283. controller Syntax DellStatus Access Read only Diskette Control Table Name disketteControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 70 Description Defines the Diskette C ontrol Table Syntax DisketteC ontrolTableE ntry Access Not accessible 410 BIOS Setup Control Group Diskette Control Table Entry Name Object ID Description Syntax Access Index disketteControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 70 1 Defines the Diskette C ontrol Table entry DellStatus Not accessible disketteC ontrolchassisI ndex disketteC ontroll ndex Diskette Control Chassis Index Name Object ID Description Syntax Access disketteControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 1 Defines the index one based of this chassis DellO bjectRange Read only Diskette Control Index Name Object ID Description Syntax Access disketteControliIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 2 Defines the index of the diskette controllers in this chassis DellO bjectRange Read only Diskette Control Capabilities Unique Name Object ID Description Syntax Access disketteControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 70 1 3 Defines the capabilities of the diskette controller DellDisketteC ontrolC apabilitiesU nique See Table 17 18 Read only 411 BIOS Setup Control Group Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 4 Description
284. ct ID 1 3 6 1 4 1 674 10899 1 1 Description Defines the locale of the system Syntax DisplayString Access Read only Inventory Schema Version Name inventorySchemaVersion Object ID 1 3 6 1 4 1 674 10899 1 2 Description Defines the inventory schema implemented by this system Syntax DisplayString Access Read only Inventory System ID Name inventorySystemID Object ID 1 3 6 1 4 1 674 10899 1 3 Description Defines the System ID for the system Syntax System D ChangeManagementGroup 673 674 Name Access inventorySystemID Read only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan dentifying information includes the Component ID the Device ID and the Vendor ID Device Group Table The following object sets up the D evice Group Table Name Object ID Description Syntax Access Device Entry Name Object ID Description Syntax Access Device Index Name Object ID Description Syntax Access deviceTable 1 3 6 1 4 1 674 10899 1 5 Defines the D evice Table SEQUENCE OF DeviceEntry Not accessible deviceEntry 1 3 6 1 4 1 674 10899 1 5 1 Defines a device entry DeviceEntry Not accessible deviceIndex 1 3 6 1 4 1 674 10899 1 5 1 1 Defines the unique index for this device Unsigned16BitR ange Read only Change M anagement Group Device Component ID Name deviceComponentID Object ID 1 3 6 1 4 1 674 10899 1 5 1
285. d connec COL PortTypelsZIFSocket 4 The processor port connector type is a Zero insertion force ZIF socket connec COL Port ypelsAPiggyBackBoard 5 The processor port connector type is a replacement piggyback board connec COL PortTypelIsNone 6 There is no processor port connector processor is soldered in place connec COL PortTypeIsLIFSocket 7 The processor port connector type is a low insertion force LIF socket connec COL PortTypelIsSlot1 8 The processor port connector type is a slot one connec COL PortTypelsSlot2 9 The processor port connector type is a slot two connec COL PortTypelIs370PinSocket 10 The processor port connector type is a 370 pin socket Port Group 257 Table 13 4 Memory Device Port Connector Types Variable Name De 1 1MemoryDevicePortConnectorType Data Type Integer Possible Data Value Meaning of Data Value connectorPortTypelIsOther 1 The memory device port connector type is not one of the following connectorPortTypelIsUnknown 2 The memory device port connector type is unknown connectorPortTypeIsSIMM 3 The memory device port connector type isa single in line memory module SIM M connectorPortTypeIsSIP 4 The memory device port connector type is a SIP connectorPortTypelIsAChip 5 The memory device port connector type is
286. d an error from which it cannot recover T he sensor location chassis location previous state and temperature sensor value are provided 700 Traps Cooling Device Traps Cooling device traps monitor how well a fan is functioning Table 27 4 Cooling Device Traps TrapID Description Severity Cause Cooling Device Normal 1102 Fan sensor returned to a normal Information A fan sensor reading on value the specified system Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt Fan sensor value lt R eading gt returned to a valid range after crossing a warning threshold T he sensor location chassis location previous state and fan sensor value are provided Cooling Device Warning 1103 Fan sensor detected a warning value Warning Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt Fan sensor value lt R eading gt A fan sensor reading in the specified system exceeded a warning threshold T he sensor location chassislocation previous state and fan sensor value are provided Traps 701 Table 27 4 Cooling Device Traps continued TrapID Description Severity Cause Cooling Device Failure 1104 Fan sensor detected a failure value Error Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt P
287. d write Parallel Port Status Name parallelPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 5 Description Defines the status of the parallel port Syntax DellStatus Access Read only Parallel Port Security State Name DellPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 6 Description Defines the security state of the parallel port Syntax DellStatus Access Read only Parallel Port Connector Type Name parallelPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 7 Description Defines the connector type of the parallel port Syntax D ellParallelPortC onnectorType Access Read only 246 Port Group Parallel Port Name Name parallelPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 8 Description Defines the name of the parallel port Syntax DellString Access Read only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 9 Description Defines the pinout of the parallel port Syntax D ellParallelPortC onnectorPinout Access Read only Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 10 Description Defines the capabilities of the parallel port Syntax D ellParallelPortC onnectorPinout Access Read only Parallel Port Base 1 0 Address Name parallelPortBaselOAddress Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 11 Description Defines the Base Input Output I O address of
288. d32BitRange Read write COO Acquisition Install Date Name Name Object ID Description Syntax Access cooAquisitionInstallDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 5 Defines the installation date and time for the system DellD ateN ame Read write COO Acquisition Purchase Order Name Object ID Description Syntax Access cooAquisitionPurchaseOrder 1 3 6 1 4 1 674 10892 1 1600 10 1 6 Defines the purchase order number of the system DellU nsigned32BitRange Read write COO Acquisition Purchase Date Name Name Object ID Description Syntax Access cooAquisitionPurchaseDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 7 Defines the purchase date and time of the system DellD ateN ame Read write Cost of Ownership Group 439 COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 8 Description Defines the name of the authorized person who signs for the system Syntax D ellC ostofO wnershipString Access Read write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 9 Description Specifies whether the purchase of this system was expensed Syntax DellBoolean Access Read write COO Original Machine Configuration Vendor Name Name cooOriginalMachineConfigurationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 10 Description Defines the vendor name of
289. define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities O bjects for the serial interface define the serial connection mode flow control type and bit rate Objects for the LAN interface define the media access control MAC address internet protocol IP address subnet mask and default gateway The following M IB tables define the BMC group Baseboard M anagement Controller Table Baseboard M anagement Controller Serial Interface Table e Baseboard M anagement Controller LAN Interface Table Baseboard Management Controller Table Name bmcTable Object ID 1 3 6 1 4 1 674 10892 1 1900 10 Description Defines the Baseboard M anagement Controller Table Syntax SEQUENCE OF BmcTableEntry Access Not accessible Baseboard Management Controller Group 531 BMC Table Entry Name Object ID Description Syntax Access Index bmcTableEntry 1 3 6 1 4 1 674 10892 1 1900 10 1 Defines the Baseboard M anagement Controller BM C Table Entry BmcTableEntry Not accessible bmcC hassisI ndex bmcl ndex BMC Chassis Index Name Object ID Description Syntax Access BMC Index Name Object ID Description Syntax Access bmcChassisIndex 1 3 6 1 4 1 674 10892 1 1900 10 1 1 Defines the index one based of the associated chassis DellO bjectRange Read only bmcIndex 1 3 6 1 4 1 674 10892 1 1900 10 1 2 Defines the index one based of the
290. der the iDRAC7 MIB 767 768 C onfiguration event category of the iD RAC 7 Configuration traps are traps generated in response to events related to hardware configuration changes and software configuration changes Table 29 40 Test Trap TrapID Description Category SubCategory Severity Test Trap Event 10395 TheiDRAC generated a Configuratio Test Alert test trap event in n response to a user request Informational iDRAC7 MIB Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry T hese are the most common data types for describing variable values defined in the 10892 mib dcs3rmt mib and dcs3fru mib files Server Administrator specific variable values are defined in the last section of the section in which they are introduced Common Data Types Common data types include several types of strings the object range signed and unsigned bit ranges and the familiar Boolean true or false data type Table 30 1 Common Data Types Variable Name Definition DellString DisplayString SIZE 0 64 DellSecurityString DisplayString SIZE 0 255 DellCostofOwnershipString DisplayString SIZE 0 64 DellObjectRange INTEGER 1 128 DellUnsigned8BitRange INTEGER 1 256 DellUnsigned16BitRange INTEGER 1 65535 DellUnsigned32BitRange INTEG
291. dex remoteAccessC hassisl ndex remoteA ccessA dapterl ndex Remote Access Group 471 Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellO bjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remote access hardware Syntax DellO bjectRange Access Read only Remote Access Type Name remoteAccessTyp Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemoteAccessT ype See Table 20 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote access hardware Syntax DellStateC apabilities Access Read only 472 Remote Access Group Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access
292. dministrator alert log and are forwarded to the W indows application alert log If you have SNMP installed on the managed system and the SNMP service is running the Storage M anagement alerts in the W indows application alert log are forwarded as SNM P traps In order for these traps to be viewable however a target system or application must be configured to receive these traps SNMP traps that are generated by Storage M anagement can be viewed in any standard SN M P compatible enterprise management console Storage ManagementAlertReference 735 The W indows SN MP service must be configured to forward the SNM P traps to the target system or application W hen forwarding to an application the application should also be configured to receive the SNM P traps The IT Assistant application is already configured to receive the SNMP traps generated by Storage M anagement See your W indows operating system documentation for information on configuring the operating system to forward SNM P traps This information may be located under such topics as setting up SNM P or SNMP traps W hen configuring SNMP for W indows be sure that the SNMP traps are forwarded to the correct server For information on configuring an application to receive SNM P traps see the documentation for that application SNMP Trap Definitions The Storage M anagement management information base MIB defines the SNMP traps that Storage M anagement generates T hes
293. driver version for Storage M anagement to support the controller Syntax DisplayString 576 l Storage M anagement Group Access controllerMinDriverVersion Read write Controller SCSI Initiator ID Name Object ID Description Syntax Access controllerSCSIInitiatorID 1 3 6 1 4 1 674 10893 1 20 130 1 1 46 TheSCSI ID of the initiator Integer Read only Controller Channel Count Name Object ID Description Syntax Access controllerChannelCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 47 The number of channels on the controller Integer Read only Controller Reconstruct Rate Name Object ID Description Syntax Access controllerReconstructRate 1 3 6 1 4 1 674 10893 1 20 130 1 1 48 The rate for reconstruct on the controller Integer Read write Controller Patrol Read Rate Name Object ID Description Syntax controllerPatrolReadRate 1 3 6 1 4 1 674 10893 1 20 130 1 1 49 The rate for patrol read on the controller Integer Storage Management Group 577 Name controllerPatrolReadRate Access Read only Controller BGI Rate Name controllerBGIRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 50 Description The rate for background initialization on the controller Syntax Integer Access Read only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 51 Description The rate for check consistency on the controller Syntax Integer Acc
294. duct and system status Storage M anagement Information Group properties about the Simple Network M anagement Protocol SNM P agent Global Data Group system status e Physical D evices Group physical devices managed by the software Logical Devices Group logical devices managed by the software Storage M anagement Event Group SNMP traps Storage Management Group The Storage M anagement Information Base MIB Group defines the properties that identify information about the Storage M anagement software product and the current status of the system it manages Software Version Name softwareVersion Object ID 1 3 6 1 4 1 674 10893 1 20 1 Description Identifies the version number of the storage management component of the systems management software Syntax DisplayString Access Read only Storage Management Group 553 Global Status Name globalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 2 Description Identifies global health for the subsystem managed by the Storage M anagement software This global status is customized for H P OpenView Other applications should refer to the agentSystemG lobalStatus entry in the globalD ata object group Possible values 1 Critical 2 Warning 3 Normal 4 Unknown Syntax Integer Access Read only Software Manufacturer Name softwareManufacturer Object ID 1 3 6 1 4 1 674 10893 1 20 3 Description Identifies the manufacturer of the Storage M anagement softwar
295. duction is divided into two sections T he first section Introduction to the SNM P Reference Guide on page 18 explains the SNM P Reference Guide design All essential Simple Network M anagement Protocol SNM P terms are defined in this section Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNM P forthe first time SNM P experts can skim this section and beginners can read the section more carefully The second section Introduction to the Server Administrator SNMP Subagent on page 33 is a more technical introduction to the management information base M1B that underlies Server Administrator services Supported SNMP Versions Operating System Supported OMSA SNMP version Windows SNMP v1 Linux SNMP v1 Introduction 17 Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenM anage Sections in this guide follow M IB groups and provide explanations and definitions for the terms used to define M IB objects C ontent in this reference guide is organized as documented in the following subsections General Content Table 1 1 describes the sections that provide general information about the M IBs documented in this guide Table 1 1 General Content Sections in This Guide Section Topics MIB Group Number 1 Introduction to SNM P basics and to t
296. e Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 8 Description Defines the mode settings of the parallel port Syntax DellParallelPortC ontrolM odeSettingsU nique See Table 17 14 Access Read write Serial Port Control Table Name serialPortControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 40 Description Defines the Serial Port C ontrol Table Syntax SerialPortC ontrolTableE ntry Access Not accessible 404 BIOS Setup Control Group Serial Port Control Table Entry Name Object ID Description Syntax Access Index serialPortControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 40 1 Defines the Serial Port Control Table entry SerialPortC ontrolTableE ntry Not accessible serialPortC ontrolchassisl ndex serialPortC ontroll ndex Serial Port Control Chassis Index Name Object ID Description Syntax Access serialPortControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 40 1 1 Defines index one based of this chassis DellO bjectRange read only Serial Port Control Index Name Object ID Description Syntax Access serialPortControliIndex 1 3 6 1 4 1 674 10892 1 1400 40 1 2 Defines the index one based of the serial port in this chassis DellO bjectRange read only Serial Port Control Capabilities Unique Name Object ID Description Syntax Access serialPortControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 40 1 3 Defines the capabilities of the serial port DellSerialPortC ontrolC apabilitiesU niqu
297. e Syntax DisplayString Access Read only Software Product Name softwareProduct Object ID 1 3 6 1 4 1 674 10893 1 20 4 Description Identifies product information for the Storage M anagement software Syntax DisplayString Access Read only 554 Storage Management Group Software Description Name softwareDescription Object ID 1 3 6 1 4 1 674 10893 1 20 5 Description Identifies the product description for the Storage Management software Syntax DisplayString Access Read only Storage Management Information Group The Storage M anagement Information M IB Group defines the properties that identify the Storage M anagement software SNM P agent Display Name Name displayName Object ID 1 3 6 1 4 1 674 10893 1 20 100 1 Description Identifies the name of this management software for display purposes Syntax DisplayString Access Read only Description Name description Object ID 1 3 6 1 4 1 674 10893 1 20 100 2 Description Provides a short description of this management software Syntax DisplayString Access Read only Storage Management Group 555 Agent Vendor Name agentVendor Object ID 1 3 6 1 4 1 674 10893 1 20 100 3 Description Identifies the name of the management software manufacturer Syntax DisplayString Access Read only Agent Version Name agentVersion Object ID 1 3 6 1 4 1 674 10893 1 20 100 4 Description This entry is obsolete Refer to softwareVersion Syntax DisplayString Access Read only Glob
298. e Object ID Description Syntax Access physicalMemoryConfigStatus 1 3 6 1 4 1 674 10892 1 1300 30 1 5 Defines the status of the physical memory configuration DellStatus Read only Physical Memory Configuration Redundant Capabilities Name Object ID Description Syntax Access physicalMemoryConfigRedundantCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 6 Defines the redundant capabilities of the physical memory DellPhysicalM emoryC onfigRedundantC apabilities Read only Physical Memory Configuration Redundant Settings Name Object ID Description Syntax Access physicalMemoryConfigRedundantSettings 1 3 6 1 4 1 674 10892 1 1300 30 1 7 Defines the redundant settings of the physical memory DellPhysicalM emoryC onfigR edundantSettings Read write Physical Memory Configuration MOM Capabilities Name Object ID Description Syntax Access physicalMemoryConfigMOMCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 8 Defines the M emory Operating M ode capabilities of the physical memory DellPhysicalM emoryC onfigM OM Capabilities Read only MemoryGroup 373 Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1 3 6 1 4 1 674 10892 1 1300 30 1 9 Description Defines the M emory Operating M ode settings of the physical memory Syntax DellPhysicalM emoryC onfigM O M Settings Access Read only Physical Memory Logging Table This table defines the conditions for loggin
299. e See Table 17 15 Read only BIOS Setup Control Group 405 Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 4 Description Defines the settings of the serial port Syntax DellSerialPortC ontrolSettingsU nique See Table 17 16 Access Read only Serial Port Control Status Name serialPortControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 5 Description Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Control Name Name serialPortControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 6 Description Defines the setup BIOS name of the serial port Syntax DellString Access Read only USB Control Table These objects enable you to track the attributes of your U niversal Serial Bus U SB Name usbControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 50 Description Defines the USB Table Syntax UsbC ontrolTableE ntry Access Not accessible 406 BIOS Setup Control Group USB Control Table Entry Name Object ID Description Syntax Access Index usbControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 50 1 Defines the USB Table entry UsbC ontrolTableEntry Not accessible usbC ontrolchassis ndex usbC ontroll ndex USB Control Chassis Index Name Object ID Description Syntax Access usbControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 50 1 1 Defines index one based of this chassis DellO bjectR
300. e 412 The following M IB table in the BIOS Setup Control Group is supported on Dell PowerE dge xx2x 12G systems BIOS Setting Table on page 415 BIOS Setup Control Table Name biosSetUpControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 10 Description Defines the set of single devices in a chassis controlled by the BIOS Syntax BiosSetU pC ontrolTableE ntry BIOS Setup Control Group 389 Name biosSetUpControlTable Access Not accessible BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 Description Defines the BIOS Control Device Table entry Syntax BiosSetU pC ontrolTableE ntry Access Not accessible Index biosSetU pC ontrolchassis ndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only BIOS Setup Control BSUC Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 2 Description Defines the capabilities of the pointing device Syntax DellStateC apabilities Access Read only BIOS Setup Control Pointing Device Control Settings Name bSUCpointingDeviceControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 3 Description Defines the state of the pointing device 390 BIOS Setup Control Group Name bSUCpointi
301. e Capabilities Variable Name De 1 1RemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial up functionality has no state capabilities unknownCapabilities 1 The dial up functionality state capabilities are unknown 520 enableCapable 2 The dial up functionality can be disabled or enabled Remote Access Group Table 20 22 Remote Dial Up State Capabilities continued Variable Name De 1 1RemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value notReadyCapable 4 The dial up functionality can be in the not ready state dialInCapable 8 The dial up functionality can support the dial in feature dialOutCapable 16 The dial up functionality can support the dial out feature dialInDHCPCapable 32 The dial up functionality can support using DHCP to obtain an IP address for the dial in feature dialInAuthAnyCapable 64 Thedial up functionality can support any authentication type including clear text for the dial in feature dialInAuthEncryptedCapable 128 Thedial up functionality can support encrypted passwords C HAP authentication for the dial in feature dialInAuthMschapCapable 256 The dial up functionality can support M SC HAP authentication type for the dial in feature Table 20 23 Remote Dial Up State Settings Variable Name
302. e Content Tables K NOTE Variable values are defined for any variable that is Server Administrator specific Industry standard variable definitions are documented in Standard Data Type Definitions on page 789 Some of the tables in this guide have no technical significance in SNM P These tables are designed to show information in a readable form The following table for example defines the Server Administrator specific variable DellFanC ontrolC apabilities T he table provides the name of the variable its data type the values that are valid for the variable and the meaning of each value Table 1 9 Example Variable Type Definition Table Variable Name Del 1FanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrhighSpeedCapable 6 The fan can be set to low or high speed This type of table is used throughout the reference guide to list and define variable values Tables that explain Server Administrator specific variable values are located in the final section of sections that define Server Administrator specific variables In the preceding example the variable name is DellFanC ontrolC apabilities T his variable must be expressed as an integer and has four possible values unknown lowSpeedC apable highSpeedC apa
303. e Entry Name Object ID Description Syntax Access Index batteryTable 1 3 6 1 4 1 674 10892 1 600 50 Defines the Battery Table SEQUENCE OF BatteryTableEntry Not accessible batteryTableEntry 1 3 6 1 4 1 674 10892 1 600 50 1 Defines the Battery Table Entry BatteryTableE ntry Not accessible batteryC hassisl ndex batteryl ndex Battery Chassis Index Name Object ID Description Syntax Access Battery Index Name Object ID Description Syntax Access batteryChassisIndex 1 3 6 1 4 1 674 10892 1 600 50 1 1 Defines the index one based of the chassis that contains the battery DellObjectRange Read only batteryIndex 1 3 6 1 4 1 674 10892 1 600 50 1 2 Defines the index one based of the battery DellObjectRange Read only Power Group Battery State Capabilities Name Object ID Description Syntax Access batteryStateCapabilities 1 3 6 1 4 1 674 10892 1 600 50 1 3 Defines the state capabilities of the battery DellStateC apabilities Read only Battery State Settings Name Object ID Description Syntax Access Battery Status Name Object ID Description Syntax Access Battery Reading Name Object ID Description Syntax Access batteryStateSettings 1 3 6 1 4 1 674 10892 1 600 50 1 4 Defines the state settings of the battery DellStateSettings Read write batteryStatus 1 3 6 1 4 1 674 10892 1 600 50 1 5 Defines the status of the battery DellStatus Read only
304. e Server Administrator generates events in response to changes in the status of sensors and other monitored parameters W hen an event with predefined characteristics occurs on your system the SNM P subagent sends information about the event along with trap variables to the management console Each status change event generates a unique identifier called the Trap D and atrap description that describes the event The Trap D and message uniquely describe the severity and cause of the event and provide other relevant information such as the location of the event and the monitored item s previous state Instrumentation Traps on page 696 lists all Server Administrator Instrumentation Trap Ds in numerical order and includes each TraplD s corresponding description severity level and cause Description text in brackets for example lt State gt describes the event specific information provided by Server Administrator RAC Traps on page 721 lists RAC Trap Dsin numerical order and includes each Trapl D s corresponding description severity level and cause BMC Traps on page 726 lists BMC Trapl Ds and includes each Trap D s corresponding description and severity level Traps 689 690 Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system T he trap variables presented here apply to all In
305. e access hardware Syntax DellO bjectRange Access Read only 478 l Remote Access Group Remote Access Type Name remoteAccessTyp Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemoteAccessT ype See Table 20 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote access hardware Syntax DellStateC apabilities Access Read only Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access Read only Remote Access Group 479 Remote Access Product Info Name Name remoteAccessProduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description D efines the description of the product providing the remote a
306. e arrayDiskLogicalConnectionDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 6 Description Identifies the name of the disk group to which this array disk belongs This property is currently not supported Syntax DisplayString Access Read only 668 Storage Management Group Array Disk Logical Connection Disk Number Name Object ID Description Syntax Access arrayDiskLogicalConnectionDiskNumber 1 3 6 1 4 1 67 4 10893 1 20 140 3 1 7 Identifies the instance number of the disk group to which this array disk belongs T his property is currently not supported Integer Read only Storage Management Event Group The Storage M anagement Event Group defines the properties that are sent with SNMP traps Message ID Event Name Object ID Description Syntax Access messagelID 1 3 6 1 4 1 67 Event 4 10893 1 20 200 1 Storage Management event message number Integer Read only Description Event Name Object ID Description Syntax Access Location Event Name Object ID descriptionEvent 1 3 6 1 4 1 67 4 10893 1 20 200 2 Storage Management event message text describing the alert DisplayString Read only locationEvent 1 3 6 1 4 1 67 4 10893 1 20 200 3 Storage Management Group 669 Name locationEvent Description Additional information identifying the location of the object causing the alert Syntax DisplayString Access Read only Object Name Event
307. e controller type and instance For example PERC 3 QC 1 Syntax DisplayString Access Read only 564 Storage Management Group Controller Vendor Name controllerVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 3 Description Identifies the controller s re seller s name Syntax DisplayString Access Read only Controller Type Name controllerType Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 4 Description Identifies the type of this controller 1 SCSI 2 PowerVault 660F 3 Power Vault 662F 4 Integrated Intelligent Drive Electronics IDE 5 Serial Advanced Technology Architecture SATA 6 Serial Attached SCSI SAS Syntax Integer Access Read only Controller State Name controllerState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 5 Description Identifies the status of the controller s subsystem which includes any devices connected to it Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Syntax Integer Access Read only Storage Management Group 565 Controller Severity Name controllerSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 6 Description This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 7 Description Identifies the percent of the compute cycles dedic
308. e first byte returned represents the status of the first amperage probe the second byte returned represents the status of the second amperage probe and so on The bytes have the same definition type as DellStatus Syntax Octet String Size 1 128 Access Read only 56 System State Group System State Cooling Unit State Details Name Object ID Description Syntax Access statesystemStateCoolingUnitStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 17 Defines the state of all cooling units in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned represents the state of the second cooling unit and so on The bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only System State Cooling Unit Status Redundancy Name Object ID Description Syntax Access systemStateCoolingUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 18 Defines the state of all cooling units in this chassis DellStatusR edundancy Read only System State Cooling Unit State Details Name Object ID Description Syntax Access systemStateCoolingUnitstateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 19 Defines the state of all cooling units in this chassis T he results are returned as a binary octet string Each byte
309. e of the SCSI port Syntax D ellG enericPortC onnectorType Access Read only Parallel Port Table Name parallelPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 70 Description Defines the Parallel Port Table Syntax IntegerParallelPortTableE ntry Access Not accessible 244 Port Group Parallel Port Table Entry Name Object ID Description Syntax Access Index parallelPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 70 1 Defines the Parallel Port Table entry ParallelPortTableE ntry Not accessible parallel Portchassis ndex parallel Port ndex Parallel Port Chassis Index Name Object ID Description Syntax Access parallelPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 70 1 1 Defines the index one based of this chassis DellO bjectRange Read only Parallel Port Index Name Object ID Description Syntax Access parallelPortIndex 1 3 6 1 4 1 674 10892 1 1000 70 1 2 Defines the index of the parallel ports in this chassis DellO bjectRange Read only Parallel Port State Capabilities Name Object ID Description Syntax Access parallelPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 70 1 3 Defines the capabilities of the parallel port D ellStateSettings Read write PortGroup 245 Parallel Port State Settings Name parallelPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 4 Description Defines the state and settings of the parallel port Syntax DellStateSettings Access Rea
310. e probe s upper nonrecoverable threshold The value is an integer representing the amperage in milliamperes that the probe is reading DellSigned32BitRange Read only Amperage Probe Upper Critical Threshold Name Object ID Description Syntax Access amperageProbeUpperCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 10 Defines the value of the amperage probe s upper critical threshold DellSigned32BitRange Read only 166 Power Group Amperage Probe Upper Noncritical Threshold Name Object ID Description Syntax Access amperageProbeUpperNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 11 Defines the user assigned value of the amperage probe s upper critical threshold DellSigned32BitRange Read write Amperage Probe Lower Noncritical Threshold Name Object ID Description Syntax Access amperageProbeLowerNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 12 Defines the user assigned value of the amperage probe s lower noncritical threshold DellSigned32BitRange Read write Amperage Probe Lower Critical Threshold Name Object ID Description Syntax Access amperageProbeLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 13 Defines the value of the amperage probe s lower critical threshold DellSigned32BitRange Read only Power Group 167 Amperage Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access amper
311. e system Syntax DellCOODayM onthD urationType Access Read write COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 6 Description Defines the warranty end date for this system Syntax DellDateName Access Read write CostofOwnership Group 453 COO Warranty Cost Name Object ID Description Syntax Access cooWarrantyCost 1 3 6 1 4 1 674 10892 1 1600 40 1 7 Defines the cost of the warranty for this system DellU nsigned32BitRange Read write COO Lease Information Table The COO lease information M IB objects enable you to track information about your lessor lease duration and lease type for each system Name Object ID Description Syntax Access cooLeaseInformationTable 1 3 6 1 4 1 674 10892 1 1600 50 Defines the COO Lease Information Table SEQUENCE OF CooL easel nformationTableE ntry Not accessible COO Lease Information Table Entry Name Object ID Description Syntax Access Index cooLeaselInformationTableEntry 1 3 6 1 4 1 674 10892 1 1600 50 1 Defines the COO Lease Information Table entry CooL easel nformationTableE ntry Not accessible cooL easel nformationchassisl ndex cooL easel nformation ndex COO Lease Information Chassis Index Name Object ID Description Syntax Access cooLeaseInformationchassisIndex 1 3 6 1 4 1 674 10892 1 1600 50 1 1 Defines the index one based of this chassis DellObjectRange Read only 454 Co
312. e traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions on page 737 section The M IB is located in sm mibs dcstorag mib a subdirectory of the Storage M anagement installation directory NOTE Storage M anagement supports trap forwarding on both 32 bit and 64 bit operating systems SNMP Trap Variables The Storage M anagement SN MP traps use a set of variables that are included with every trap T hese variables are the following e messagelD Event e descriptionEvent locationE vent e objectN ameE vent objectOID Event e objectN exusE vent e currentStatusE vent e previousStatusE vent 736 Storage Management Alert Reference Viewing SNMP Traps SNMP traps that are generated by Storage M anagement can be viewed in any standard SNM P compatible enterprise management console T hese traps are defined in the Storage Management M IB These traps correspond to the alerts documented in the Alert D escriptions and C orrective Actions section For more information on the M IB and its structure as well as a change history of the SNMP traps see the Introduction on page 17 section For more information on configuring SNMP see SNM P Support for Storage Management Alerts on page 735 Alert Descriptions and Corrective Actions The alerts generated by the redundant array of independent disks RAID or Small Computer System Interface SC SI controllers and support
313. e was removed from the specified system The device location chassis location and additional event details if available are provided 718 Traps Battery Traps Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries Table 27 16 Battery Traps TrapID Description Cause Battery Normal 1702 Battery sensor returned to anormal value Sensor Location lt L ocation in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt A battery sensor in the specified system detected that a battery transitioned back to anormal state The sensor location chassis location previous state and battery sensor status are provided Battery Warning 1703 Battery sensor detected a warning value or Battery is low Sensor Location lt L ocation in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt Battery Failure 1704 Battery sensor detected a failure value or Battery has failed or is absent Sensor Location lt L ocation in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt A battery sensor in the specified system detected that abatteryisina predictive failure state The sensor location chassis lo
314. eC apabilities Read only Cooling Device State Settings Name Object ID Description Syntax Access coolingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 700 12 1 4 Defines the state and settings of the cooling device DellStateSettings Read write Cooling Device Status Name Object ID Description Syntax Access coolingDeviceStatus 1 3 6 1 4 1 674 10892 1 700 12 1 5 Defines the status of the cooling device DellStatusProbe Read only Thermal Group 203 Cooling Device Reading Name Object ID Description Syntax Access coolingDeviceReading 1 3 6 1 4 1 674 10892 1 700 12 1 6 Defines either the cooling device s speed in revolutions per minute RPM or the off on value of the fan W hen the value for coolingD eviceSubType is other than coolingD eviceSubTypelsD iscrete the value returned for this attribute is the speed in RPM or the OFF ON value of the cooling device W hen the value for coolingD eviceSubType is coolingD eviceSubTypelsD iscrete a value is not returned for this attribute DellSigned32BitRange Read only Cooling Device Type Name Object ID Description Syntax Access coolingDeviceType 1 3 6 1 4 1 674 10892 1 700 12 1 7 Defines the cooling device type DellC oolingD eviceType See Table 10 1 Read only Cooling Device Location Name Name Object ID Description Syntax Access coolingDeviceLocationName 1 3 6 1 4 1 674 10892 1 700 12 1 8 Defines the location of the c
315. eInterval Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 62 Storage Management Group 581 Name controllerSpinDownTimeInterval Description Shows the duration in minutes after which the unconfigured or hot spare drives is spun down to power save mode Value 30 to 1440 K NOTE A value of 9999 indicates that the feature is not available Syntax Integer Access Read write Controller Encryption Mode Name controllerEncryptionMode Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 63 Description Indicates the current encryption mode of the controller Value 0 No Encryption 1 Local Key Management LKM 2 Dell Key Management DKM 99 Not Applicable Syntax Integer Access Read only Controller CacheCade Name controllerCacheCade Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 64 Description Indicates if the controller is C acheC ade capable or not Value 1 Capable 0 Not Capable 99 Undetermined Syntax Integer Access Read only 582 Storage Management Group Channel Table This table describes available properties for each channel on the managed system The following object sets up the Channel Table Name channelTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 Description Defines the channel table Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 Description D efines the channel table entry Syntax ChannelEntry
316. eNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 8 Defines the device number of the PC device in this chassis DellU nsigned32BitRange Read only 302 Device Group PCI Device Configuration Space Function Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceFunctionNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 9 Defines the function number of the PCI device in this chassis DellU nsigned32BitRange Read only PCI Device Configuration Space Header Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceHeader 1 3 6 1 4 1 674 10892 1 1100 82 1 10 Defines the common configuration space header of the PC device Octet String SIZE 0 1025 Read only Network Device Table Name Object ID Description Syntax Access networkDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 90 Defines the Network D evice Table SEQUENCE OF NetworkD eviceTableE ntry Not accessible Network Device Table Entry Name Object ID Description Syntax Access Index networkDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 90 1 Defines the Network D evice Table Entry N etworkD eviceTableE ntry Not accessible networkD eviceC hassisl ndex networkD evicel ndex DeviceGroup 303 Network Device Chassis Index Name Object ID Description Syntax Access networkDeviceChassisIndex 1 3 6 1 4 1 674 10892 1 1100 90 1 1 Defines the index one based of the chassis that contains the network device
317. ead only BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 4 Description Defines the state capabilities of the BMC LAN interface Syntax DellStateC apabilities Access Read only BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 5 Description Defines the state settings of the BMC LAN interface Syntax DellStateSettings Access Read write 540 Baseboard M anagement Controller Group BMC LAN Interface Status Name Object ID Description Syntax Access bmcLANInterfaceStatus 1 3 6 1 4 1 674 10892 1 1900 30 1 6 Defines the status of the BMC LAN interface DellStatus Read only BMC LAN Interface Channel Number Name Object ID Description Syntax Access bmcLANInterfaceChannelNumber 1 3 6 1 4 1 674 10892 1 1900 30 1 7 Defines the BMC channel number of the BMC LAN interface DellU nsigned8BitRange Read only BMC LAN Interface IP Address Source Name Object ID Description Syntax Access bmcLANInterfaceIPAddressSource 1 3 6 1 4 1 674 10892 1 1900 30 1 8 Defines the source type of the IP address of the BMC LAN interface DellIBMCLANIPAddressSourceType Read only BMC LAN Interface IP Address Name Object ID Description Syntax Access bmcLANInterfaceIPAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 9 Defines the IP address of the BMC LAN interface pAddress R
318. ead only Baseboard Management Controller Group 541 BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 10 Description Defines the subnet mask of the BMC LAN interface Syntax pAddress Access Read only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 11 Description Defines the IP address of the default gateway for the BMC LAN interface Syntax pAddress Access Read only BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 12 Description Defines the MAC address of the BMC LAN interface Syntax DellM AC Address Access Read only BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunit yName Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 13 Description Defines the SNM P community used for BMC LAN alerts traps sent on the BMC LAN interface Syntax DisplayString SIZE 0 32 Access Read only 542 Baseboard M anagement Controller Group Baseboard Management Controller Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 22 1 BMC Serial Connection Mode Capabilities Variable Name De 1 1BMCSerialConnectionModeCapabilities Data Type Integer These values are bit masks therefore combination values are possib
319. ead only Processor Port Connector Type Name Object ID Description Syntax Access processorPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 30 1 7 Defines the connector type of the processor port D ellProcessorPortC onnectorType See Table 13 3 Read only Processor Port Name Name Object ID Description Syntax Access processorPortName 1 3 6 1 4 1 674 10892 1 1000 30 1 8 Defines name of the processor port DellString Read only Processor Port BIOS Connector Type Name Object ID Description Syntax Access processorPortBIOSConnectortType 1 3 6 1 4 1 674 10892 1 1000 30 1 9 Defines the BIOS connector type of the processor port D ellG enericPortC onnectorType Read only PortGroup 235 Memory Device Port Table Name Object ID Description Syntax Access memoryDevicePortTable 1 3 6 1 4 1 674 10892 1 1000 40 Defines the M emory Device Port Table IntegerM emoryD evicePortTableE ntry Not accessible Memory Device Port Table Entry Name Object ID Description Syntax Access Index memoryDevicePortTableEntry 1 3 6 1 4 1 674 10892 1 1000 40 1 Defines the M emory D evice Port Table entry M emoryD evicePortTableE ntry Not accessible memoryD evicePortchassisl ndex memoryD evicePort ndex Memory Device Port Chassis Index Name Object ID Description Syntax Access memoryDevicePortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 40 1 1 Defines the index one based of this chassis DellO
320. ect ID 1 3 6 1 4 1 674 10892 1 300 80 1 13 Description Defines the baseboard service tag name Syntax DellString Access Read only Baseboard Piece Part ID PPID Name Name baseBoardPiecePart IDName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 14 Description Defines the baseboard PPID Syntax DellString Access Read only Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 15 Description Defines the baseboard asset tag name Syntax DellString Access Read only Chassis InformationGroup 107 Baseboard Express Service Code Name Name baseBoardExpressServiceCodeNam Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 16 Description Defines the express service code of the baseboard Syntax DellString Access Read only Chassis Information Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 6 1 Log Format Variable Name De 1 1 LogFormat Data Type Integer Possible Data Values Meaning of Data Value raw 1 The log is in the format received from the firmware ascii 2 The log isin ASCII format uniCode 3 The log is in Unicode format Table 6 2 Chassis Type Variable Name Del 1ChassisType Data Type Integer Possible Data Values Meaning of Data Value other 1 The chassis type is not one of the following unknown 2 The chassis type is unknown de
321. ect ID 1 3 6 1 4 1 674 10892 2 3 1 1 Description Defines the overall chassis status being monitored by the chassis management card Syntax DellStatus Access Read only Dell Remote Access Controller Out of Band Group 695 DRslOMCurrStatus Name DRslOMCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 2 Description Definesthe OM subsystem status being monitored by the chassis management card Syntax DellStatus Access Read only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 3 Description DefinestheiKVM subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsRedCurrStatus Name DRsRedCurrtatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 4 Description Defines the redundancy status being monitored by the chassis management card Syntax DellStatus Access Read only 696 Dell Remote Access Controller Out of Band Group DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 5 Description Defines the power subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 6 Description Defines the fan subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsBladeCurrStatus Name DRsBladeCurrStatus Object ID 1 3 6 1 4 1 674 10892
322. ect ID 1 3 6 1 4 1 674 10893 1 20 110 12 Description Identifies the Universal Resource Locator URL of the systems management software Syntax DisplayString Access Read only Agent Global System Status Name agentGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 13 Description Global health information for the subsystem managed by the Storage M anagement software This global status should be used by applications other than HP OpenView HP OpenView should refer to the globalStatus in the root level object group Thisisa rollup for the entire agent including any monitored devices The status is intended to give initiative to an SNM P monitor to get further data when this status is abnormal Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 560 Storage Management Group Agent Last Global System Status Name Object ID Description Syntax Access agentLastGlobalSystemStatus 1 3 6 1 4 1 674 10893 1 20 110 14 The previous global status of the system managed by the Storage M anagement software Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Agent Smart Thermal Shutdown Name Object ID Description Syntax Access agentSmartThermalShutdown 1 3 6 1 4 1 674 10893 1 20 110 15 Indicates the status of smart thermal shutdown for PowerVault 220S and
323. ect has no settings capabilities and its state is disabled unknown 1 The object s state is unknown enabled 2 The object s state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The object is not ready enableAndNotReady 6 The object is enabled and not ready Table 30 4 Dell Probe Capabilities Variable Name De11ProbeCapabilities Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities upperNonCriticalThresholdSet The upper noncritical threshold Capable 1 can be set lowerNonCriticalThresholdSet The lower noncritical threshold Capable 2 can be set upperNonCriticalThresholdDef The upper noncritical threshold aultCapable 4 can be set to default lowerNonCriticalThresholdDef The lower noncritical threshold aultCapable 8 can be set to default Standard Data Type Definitions 791 Dell Status Data Types Status data types include D ellStatus D ellStatusR edundancy and DellStatusProbe Table 30 5 Dell Status Variable Name De11Status Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The object s status is unknown ok 3 The object s status is OK nonCritical 4 The object s status is warning noncritical critical 5 The object
324. ed Bit 7Smart Battery supported DellU nsigned8BitRange Read only System BIOS Characteristics Ext 2 Name Object ID Description Syntax Access systemBIOSCharacteristicsExt2 1 3 6 1 4 1 674 10892 1 300 50 1 14 Defines additional characteristics of the system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit OBIOS Boot Specification supported Bit 1Function key initiated Network Service boot supported Bit 2Targeted C ontent Distribution supported Bit 3 7Reserved DellU nsigned8BitRange Read only Chassis InformationGroup 97 Firmware Table Name firmwareTable Object ID 1 3 6 1 4 1 674 10892 1 300 60 Description Defines the Firmware Table Syntax SEQUENCE OF FirmwareTableE ntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 Description Defines the Firmware Table entry Syntax FirmwareTableE ntry Access Not accessible Index firmwarechassis ndex firmwarel ndex Firmware Chassis Index Name firmwarechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Firmware Index Name firmwareIndex Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 2 Description Defines the index one based of the firmware in this chassis Syntax DellObjectRange Access Read only
325. ed failure or critical critical threshold value 1012 alertDrscVolt TheRAC Information Error RAC voltage DRAC Normal voltage has probereading III returned toa returns to normal value normal 1013 alertDrscVolt TheRAC M inor Error RAC voltage DRAC Warning voltage probe reading III probe has exceeded detected a warning warning threshold value 1014 alertDrscVolt The RAC Critical Error RAC voltage DRAC Critical voltage probe reading III probe has exceeded detected a critical failure or threshold critical value 724 l Traps Table 27 19 Enterprise specific Traps continued TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1015 alertDrscSEL TheRAC M ajor Error RAC All Warning has detected detected a anew event new system in the event log with System warning Event Log severity with detailed log Severity info is in Warning drsAlert Message varbind 1016 alertDrscSEL_ TheRAC Critical Error RAC All Critical has detected detected a anew event new system in the event log with System critical Event Log severity with detailed log Severity info is in Critical drsAlert M essage varbind 1017 alertDrscSEL_ TheRAC M ajor Status RAC All 80 system event detected percentFull log is 80 system event full log is 80 full 1018 alertDrscSEL TheRAC M ajor Status RAC All 90 system event detected percentFull log is 90 system event full log is 90 full Traps 725 Table 27 19 Enter
326. ed of this chassis DellO bjectRange Read only Physical Memory Array Mapped Index Name Object ID Description Syntax Access physicalMemoryArrayMappedIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 2 Defines the index one based of the memory array mapped address in this chassis DellO bjectRange Read only Physical Memory Array Mapped State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayMappedStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 20 1 3 Defines the capabilities of the memory array mapped address DellStateC apabilities Read only Physical Memory Array Mapped State Settings Name Object ID Description Syntax Access physicalMemoryArrayMappedStateSettings 1 3 6 1 4 1 674 10892 1 1300 20 1 4 Defines the state of the memory array mapped address DellStateSettings Read write MemoryGroup 369 Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 20 1 5 Description Defines the status of the memory array mapped address Syntax DellStatus Access Read only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1300 20 1 6 Description Defines the index to the associated physical memory array in this chassis Syntax DellObjectRange Access Read only Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress O
327. ed by Storage M anagement are displayed in the Server Administrator Alert subtab or through W indows Event Viewer T hese alerts can also be forwarded as SNMP traps to other applications SNMP traps that are generated for the alerts are included in the Storage M anagement MIB The SNMP traps for these alerts use all of the SN MP trap variables For the list of storage management alerts and storage management messages see the D ell O penM anage Server Administrator M essages R eference Guide available on the Dell Support website at support dell com manuals Storage ManagementAlertReference 737 738 Storage Management Alert Reference IDRAC7 MIB The Integrated D ell Remote Access C ontroller iD RAC M IB filename iD RAC M IB txt is the MIB supported by the Integrated Dell Remote Access Controller 7 iD RAC 7 This MIB provides management data that allows you to monitor devices and software on a system via an out of band connection to the iD RAC 7 of a system Supported Systems TheiDRAC7 MIB is supported on the following systems Blade Servers e PowerEdge M 620 Rack and Tower Servers PowerEdge R620 e PowerEdge R720 e PowerEdge R720XD PowerEdge R820 PowerEdge T 620 IDRAC7 Supported SNMP Versions The following table identifies the SNM P version s that are supported by iDRAC7 for the given SNMP operations SNMP Operations Supported SNMP version GET GETNEXT SNMP v1 and v2c GETBULK TRAP SNMP v1 iDRAC M
328. efer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own 2012 3 Contents 1 Introduction uc 24420 5454 50204 B85 17 Supported SNMP Versions 17 Introduction to the SNMP Reference Guide 18 Server Administrator Instrumentation MIB 18 Server Administrator Remote Access MIB 21 Server Administrator Baseboard M anagement Controller ASF MB stent a E a a E Dr E A 21 Server Administrator Field Replaceable Unit MIB 22 Server Administrator Storage Management MIB 22 Server Administrator Change Management MIB 23 Dell Remote Access Controller Out of BandMIB 24 How This Guide Defines Technical Terms 24 SNMP Basic Terminology 25 Frequently Used Terms in Variable Names 28 TADICS 2 ioa a a e a a te ae aber Seeks 29 Section Organization oaoa aaa 32 Other Documents You May Need 33 Introduction to the Server Administrator SNMP Subagent 33 SNMP Management Information Base Object Identifiers 35 SNMP Securit acm tacit wine te EA 36 Management Actions 37 SNMP Traps r A pala wala eG aaa ale 37 2 Dell OpenManage Server Administrator Version 7 0 39 What s New in This Release 39 Contents 3 Server Administrator Instrumentation MIB 39 DRACI M IB ried tech Bena a Oe Bee 39 Instrumentation MIB Version Group
329. el indicates the nature of the alert 734 Storage Management Alert Reference The alert severity levels are as follows Table 28 1 Storage Management Alert Severity Alert Severity Component Status OK Normal Informational No action is required The alert is provided for informational purposes and does not indicate an error condition For example the alert may indicate the normal start or stop of an operation Warning N on critical A component requires attention This alert indicates a potential problem but does not necessarily mean that the system has currently lost data or is nonfunctional For example a W arning Non critical alert may indicate that a component such as a temperature probe in an enclosure has crossed a warning threshold C ritical Failure E rror A component has either failed or failure is imminent This alert indicates a serious problem such as data loss or a loss of function For example a C ritical F ailure E rror alert may indicate that an array disk has failed SNMP Support for Storage Management Alerts By default Storage Management installs SNM P trap forwarding support For this support to function you should have SNMP installed on the managed system prior to installing Storage Management NOTE For more information on installation requirements and SNMP see the Server Administrator documentation SNMP Trap Forwarding The Storage M anagement alerts are displayed in the Server A
330. ellStateSettings Read write System Resource Owner Status Name Object ID Description Syntax Access systemResourceOwnerStatus 1 3 6 1 4 1 674 10892 1 500 20 1 5 Defines the status of this system resource owner DellStatus Read write System Resource Owner Interface Type Name Object ID Description Syntax Access systemResourceOwnerInterfaceTyp 1 3 6 1 4 1 674 10892 1 500 20 1 6 Defines the interface type for this system resource owner DellResourceO wnerInterfaceType See Table 8 2 Read only System Resource Map Index Reference Name Object ID Description Syntax Access systemResourceMapIndexReferenc 1 3 6 1 4 1 674 10892 1 500 20 1 7 Defines the index to the associated system resource map in this chassis DellO bjectRange Read only System Resource Group 133 System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 8 Description Defines the description name of the system resource owner Syntax DellString Access Read only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 9 Description Defines the associated system resource owner interface instance in this chassis Syntax DellO bjectRange Access Read only System Resource Input Output 1 0 Port Table Name systemResourcelOPortTable Object ID 1 3 6 1 4 1 674 10892 1 500 30
331. ement controller Syntax DellString Access Read only DRsProductManufacturer Name DRsProductManufacturer Object ID 1 3 6 1 4 1 674 10892 2 1 1 4 Description Defines the product manufacturer of a chassis management controller Syntax DellString Access Read only DRsProductVersion Name DRsProductVersion Object ID 1 3 6 1 4 1 674 10892 2 1 1 5 Description Defines the product version of a chassis management controller Syntax DellString Access Read only DRsChassisServiceTag Name DRsChassisServiceTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 6 Description Defines the Service Tag of the chassis Syntax DellString Access Read only 692 Dell Remote Access Controller Out of Band Group DRsProductURL Name Object ID Description Syntax Access DrsProductURL 1 3 6 1 4 1 674 10892 2 1 1 7 Defines the out of band UI URL of a chassis management controller DellString Read only DRsProductChassisAssetTag Name Object ID Description Syntax Access DRsProductChassisAssetTag 1 3 6 1 4 1 674 10892 2 1 1 8 Defines the Asset Tag of the chassis DellString Read only DRsProductChassisLocation Name Object ID Description Syntax Access DRsProductChassisLocation 1 3 6 1 4 1 674 10892 2 1 1 9 Defines the location of the chassis DellString Read only DRsProductChassisName Name Object ID Description Syntax Access DrsProductChassisName 1 3 6 1 4 1 674 10892 2 1 1 10 Defines the name of the cha
332. ementSetting 1 3 6 1 4 1 674 10892 1 600 70 1 6 Defines the custom CPU power and performance management setting for the Custom power profile DellC PU PowerPerformanceM anagementType Read only Power Profile Custom Memory Management Capabilities Name Object ID Description Syntax Access powerProfileCustomMemoryManagementCapabiliti es 1 3 6 1 4 1 674 10892 1 600 70 1 7 Defines the custom memory power and performance management capabilities that are available for the C ustom power profile DellM emoryPowerPerformanceM anagementT ype Read only 184 Power Group Power Profile Custom Memory Management Setting Name Object ID Description Syntax Access powerProfileCustomMemoryManagementSetting 1 3 6 1 4 1 674 10892 1 600 70 1 8 Defines the custom memory power and performance management setting for the C ustom power profile DellM emoryPowerPerformanceM anagementType Read only Power Profile Custom Fan Management Capabilities Name Object ID Description Syntax Access powerProfileCustomFanManagementCapabilities 1 3 6 1 4 1 674 10892 1 600 70 1 9 Defines the custom fan power and performance management capabilities that are available for the C ustom power profile DellFanPowerPerformanceM anagementType Read only Power Profile Custom Fan Management Setting Name Object ID Description Syntax Access powerProfileCustomFanManagementSetting 1 3 6 1 4 1 674 10892 1 600 70 1 10
333. emory array ECC typeis Correctable Memory Event ECC memoryArrayECCTypeIsMultiBitECC 6 Thememory array ECC typeis Uncorrectable M emory Event ECC memoryArrayECCTypelIsCRC 7 The memory array ECC type is CRC Table 16 3 Physical Memory Configuration State Capabilities Variable Name De 1 1PhysicalMemoryConfigStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero T here are no state capabilities unknownCapabilities 1 State capabilities are unknown enableCapable 2 Object enable disable is supported notReadyCapable 4 Object not ready is supported 384 Memory Group Table 16 4 Physical Memory Configuration State Settings Variable Name De11PhysicalMemoryConfigStateSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no state settings unknown 1 State settings are unknown enabled 2 Object is disabled offline 0 or enabled online 1 not Ready 4 Object not ready redundantMemoryIsActive 8 eS memory is active in use enabledAndRedundantMemoryIsActive 10 Redundant memory is enabled and in use Table 16 5 Physical Memory Configuration Redundant Capabilities Variable Name DellPhysicalMemoryConfigRedundantCapabilities Data Type Integer Possible Data Values Meaning of Data Value I
334. emote Access Controller 6 BMC mode iDRAC7 16 Controller type is Integrated D ell Remote Access Controller 7 iDRAC7Modular 17 Controller type is Integrated D ell Remote Access Controller 7 Modular Baseboard Management Controller Group 545 546 Baseboard M anagement Controller Group Field Replaceable Unit Group A field replaceable unit FRU is apart that can be removed and replaced without having to send the system to a repair facility The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer serial number part number and revision for field replaceable units The following M IB tables define the FRU group Field Replaceable Unit Table Name fruTable Object ID 1 3 6 1 4 1 674 10892 1 2000 10 Description Defines the Field Replaceable Unit table Syntax SEQUENCE OF FruTableEntry Access Not accessible FRU Table Entry Name fruTableEntry Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 Description Defines the FRU Table Entry Syntax FruTableEntry Access Not accessible Index fruC hassis ndex frulndex Field Replaceable Unit Group 547 FRU Chassis Index Name fruChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 1 Description Defines the index one based of the chassis containing the FRU Syntax DellO bjectRan
335. ent information base M IB Values are shown for each object identifier OID in the Instrumentation MIB Version Group the Systems M anagement Software Group the System State Group the Chassis Information Table and Event Log Table T he data is from a Dell PowerEdge 2650 system Walk 1 3 6 1 4 1 674 10892 Agent SERVEROL Community public iso org dod internet private enterprises dell server3 1 3 6 1 4 1 674 10892 1 1 1 0 5 1 3 6 1 4 1 674 10892 1 1 2 0 3 1 3 6 1 4 1 674 10892 1 1 3 0 0 1 3 6 1 4 1 674 10892 1 100 1 0 Server Administrator 1 3 6 1 4 1 674 10892 1 100 2 0 5 3 0 1 3 6 1 4 1 674 10892 1 100 3 0 4522 1 3 6 1 4 1 674 10892 1 100 4 0 Management software for Dell systems 1 3 6 1 4 1 674 10892 1 100 5 0 1 1 3 6 1 4 1 674 10892 1 100 6 0 1 1 3 6 1 4 1 674 10892 1 100 7 0 No Updates SNMP Sample Output 795 1 3 6 1 4 1 674 10892 1 100 8 0 https 1 2 3 4 1311 1 3 6 1 4 1 674 10892 1 100 9 0 en_US 1 3 6 1 4 1 674 10892 1 100 10 0 2 2 0 1 3 6 1 4 1 674 10892 1 100 11 0 0 Teeb b 4 e674 0892 1700 20 00 T 1 3 6 1 4 1 674 10892 1 100 13 0 Dell Inc 1 3 6 1 4 1 674 10892 1 200 10 1 1 1 1 1 3601 441 674 10092 72 200s 10120 3 1 326ul Asi O74 108 9851 200820 s13 1 2 1 3 6 1 4 1 674 10892 1 200 10 1 4 3 1 3 6 1 4 1 674 10892 1 200 10 1 5 1 02 1 3 6 1 4 1 674 10892 1 200 10 1 6 1 3 1 3 6 1 4 1 6
336. es format of the POST log Syntax DellL ogFormat See Table 6 1 Access Read only Event Log Table Name eventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 40 Description Defines the Event Log Table Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Event Log Table Entry Object ID eventLogTableEntry 1 3 6 1 4 1 674 10892 1 300 40 1 88 Chassis Information Group Name Description Syntax Access Index eventLogTableEntry Defines the event L og Table Entry EventL ogTableE ntry Not accessible eventL ogchassis ndex eventL ogR ecord ndex Event Log Chassis Index Name Object ID Description Syntax Access event LogchassisIndex 1 3 6 1 4 1 674 10892 1 300 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Event Log Record Index Name Object ID Description Syntax Access event LogRecordIndex 1 3 6 1 4 1 674 10892 1 300 40 1 2 Defines the record index of the event log DellU nsigned32BitRange Read only Event Log State Capabilities Unique Name Object ID Description Syntax Access eventLogStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 40 1 3 Defines the capabilities of the object that is writing the event log DellStateC apabilitiesL ogU nique Read only 89 Chassis Information Group Event Log State Settings Unique Name event LogStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 4 Description Defines the
337. es of the voltage probe D ellStateC apabilities Read only Voltage Probe State Settings Name Object ID Description Syntax Access voltageProbeStateSettings 1 3 6 1 4 1 674 10892 1 600 20 1 4 Defines the state and settings of the voltage probe DellStateSettings Read write Voltage Probe Status Name Object ID Description Syntax Access voltageProbeStatus 1 3 6 1 4 1 674 10892 1 600 20 1 5 Defines the status of the voltage probe DellStatusProbe Read only Power Group 159 Voltage Probe Reading Name voltageProbeReading Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 6 Description Defines the value of the voltage probe reading T he value is an integer representing the voltage in millivolts that the probe is reading W hen the value for voltageProbeType is voltageProbeT ypel sD iscrete a value is not returned for this attribute Syntax D ellSigned32BitR ange Access Read only Voltage Probe Type Name voltageProbeType Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 7 Description Defines the type of the voltage probe Syntax DellVoltageType Access Read only Voltage Probe Location Name Name Object ID Description Syntax Access voltageProbeLocationName 1 3 6 1 4 1 674 10892 1 600 20 1 8 Defines the location of the voltage probe in this chassis DellString Read only Voltage Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax 160 voltageProbeUpperNonRecoverableThr
338. es the index one based of this chassis Syntax DellObjectRange Access Read only COO Options Index Name cooOptionsIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 2 Description Defines the index one based of the option information for this system Syntax DellObjectRange Access Read only COO Options State Name cooOptionsState Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 3 Description Defines the option information state for this system Syntax DellStateSettings Access Read only CostofOwnership Group 459 COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 4 Description Defines the lease information index of the option information for this system Syntax DellU nsigned32BitRange Access Read write COO Options Description Name Name cooOptionsDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 5 Description Defines the option information description name Syntax DellC ostofO wnershipString Access Read write COO Maintenance Table Name cooMaintenanceTable Object ID 1 3 6 1 4 1 674 10892 1 1600 80 Description Defines the COO Maintenance Table Syntax SEQUENCE OF CooM aintenanceTableE ntry Access Not accessible COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 Description Defines the COO Maintenance Table entry Syntax CooM aintenanceT ableE ntry Access N
339. es the state capabilities of the Physical M emory C ard Syntax DellStateC apabilities Access Read only Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1300 60 1 4 Description Defines the state settings of the Physical M emory Card Syntax DellStateSettings Access Read write Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 60 1 5 Description Defines the status of the Physical M emory C ard Syntax DellStatus Access Read only 380 Memory Group Physical Memory Card Name Name Object ID Description Syntax Access physicalMemoryCardName 1 3 6 1 4 1 674 10892 1 1300 60 1 6 Defines the name of the Physical M emory C ard DellString Read only Physical Memory Card Total Number Sockets Name Object ID Description Syntax Access physicalMemoryCardTotalNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 7 Defines the total number of memory sockets available on the Physical M emory Card 2 147 483 647 indicates an unknown number of sockets DellU nsigned32BitRange Read only Physical Memory Card In Use Number Sockets Name Object ID Description Syntax Access physicalMemoryCardInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 8 Defines the number of memory sockets in use on the Physical Memory Card Zero indicates that the Physical M emory C ard is not installed or has a configuration
340. escription Identifies the power supply s re seller s name Syntax DisplayString Access Read only Storage Management Group 627 Power Supply State Name powerSupplyState Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 4 Description Identifies the current state of the power supply Possible states 0 Unknown 1 Ready 2 Failed 5 Not Installed 6 D egraded 11 Removed Syntax Integer Access Read only Power Supply Severity Name powerSupplySeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 5 Description This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only Power Supply 1 Part Number Name powerSupplylPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 6 Description Identifies the part number of the power supply of the enclosure Syntax DisplayString Access Read only 628 Storage Management Group Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 7 Description This entry is obsolete T his setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read only Power Supply Roll Up Status Name powerSupplyRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 8 Description Severity of the power supply state This is the combined status of the power supply and its components Possible values 1 Other 2 U
341. escription This attribute defines the D ata C enter locator of the system Syntax StringType Access Read only 744 iDRAC7 MIB System Aisle Name Name systemAisleName Object ID 1 3 6 1 4 1 674 10892 5 1 3 9 0 Description This attribute defines the Aisle locator of the system Syntax StringType Access Read only System Rack Name Name systemRackName Object ID 1 3 6 1 4 1 674 10892 5 1 3 10 0 Description This attribute defines the Rack locator of the system Syntax StringType Access Read only System Rack Slot Name systemRackSlot Object ID 1 3 6 1 4 1 674 10892 5 1 3 11 0 Description This attribute defines the Rack Slot locator of the system Syntax StringType Access Read only System Model Name Name systemModelName Object ID 1 3 6 1 4 1 674 10892 5 1 3 12 0 Description This attribute defines the model name of the system Syntax StringType Access Read only iIDRAC7MIB 745 Status Group The Status Group objects provide status information about the system and storage Global System Status Name globalSystemStatus Object ID 1 3 6 1 4 1 674 10892 5 2 1 0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card Syntax ObjectStatusE num Access Read only System LCD Status Name systemLCDStatus Object ID 1 3 6 1 4 1 674 10892 5 2 2 0 Description This attribute defines the system status as it is reflected by the LCD front panel
342. eshold 1 3 6 1 4 1 674 10892 1 600 20 1 9 Defines the value of the voltage probe s upper nonrecoverable threshold DellSigned32BitRange Power Group Name voltageProbeUpperNonRecoverableThreshold Access Read only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 10 Description Defines the value of the voltage probe s upper critical threshold Syntax DellSigned32BitRange Access Read only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 11 Description Defines the user assigned value of the voltage probe s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 12 Description Defines the user assigned value of the voltage probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write 161 Power Group Voltage Probe Lower Critical Threshold Name Object ID Description Syntax Access voltageProbeLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 13 Defines the value of the voltage probe s lower critical threshold DellSigned32BitRange Read only Voltage Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access voltageProbeLowerNonRecover
343. esourceMapChassisIndex 1 3 6 1 4 1 674 10892 1 500 10 1 1 Defines the index one based of this chassis DellO bjectRange Read only System Resource Map Index Name Object ID Description Syntax Access systemResourceMapIndex 1 3 6 1 4 1 674 10892 1 500 10 1 2 Defines the index of system resource maps in this chassis DellO bjectRange Read only System Resource Map State Capabilities Name Object ID Description Syntax Access systemResourceMapStateCapabilities 1 3 6 1 4 1 674 10892 1 500 10 1 3 Defines the capabilities of this system map DellStateC apabilities Read only 130 l System Resource Group System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 4 Description Defines the state and allows the setting of this system map Syntax DellStateSettings Access Read write System Resource Map Status Name systemResourceMapStatus Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 5 Description Defines the status of this system map Syntax DellStatus Access Read only System Resource Map Type Name systemResourceMapTyp Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 6 Description Defines the type of this system map Syntax DellSystemResourceM apType See Table 8 1 Access Read only System Resource Owner Table Name systemResourceOwnerTabl Object ID 1 3 6 1 4 1 674 10892 1 500 20 Description Defines the System Resource O wner Table Syntax SEQUEN
344. ess temperatureProbeStateSettings 1 3 6 1 4 1 674 10892 1 700 20 1 4 Defines the state and settings of the temperature probe DellStateSettings Read write Temperature Probe Status Name Object ID Description Syntax Access temperatureProbeStatus 1 3 6 1 4 1 674 10892 1 700 20 1 5 Defines the status of the temperature probe in tenths of degrees Celsius DellStatusProbe Read only Temperature Probe Reading Name Object ID Description Syntax Access temperatureProbeReading 1 3 6 1 4 1 674 10892 1 700 20 1 6 Defines the value of the temperature probe W hen the value for temperatureProbeType is other than temperatureProbeTypel sD iscrete the value returned for this attribute is the temperature that the probe is reading in tenths of degrees C entigrade W hen the value for temperatureProbeT ype is temperatureProbeT ypel sD iscrete a value is not returned for this attribute DellSigned32BitRange Read only ThermalGroup 209 Temperature Probe Type Name Object ID Description Syntax Access temperatureProbeTyp 1 3 6 1 4 1 674 10892 1 700 20 1 7 Defines the temperature probe type DellTemperatureProbeT ype See Table 10 4 Read only Temperature Probe Location Name Name Object ID Description Syntax Access temperatureProbeLocationName 1 3 6 1 4 1 674 10892 1 700 20 1 8 Defines the location of the temperature probe in this chassis DellString Read only Temperat
345. ess 1RAGlobalThermalShutdownStateSettingsUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 6 Defines the set of thermal shutdown state and settings that the local response agent supports DellLRAT hermalShutdownStateSettingsU nique Read write LocalResponseAgentGroup 431 LRA Action Table TheDellLocalResponseAgentCapabilitiesUnique variablein the global action table defines the capabilities that are allowed for a particular system The LRA Action Table that follows selects which of the system s capabilities global actions are to be enabled Name 1RAActionTableTable Object ID 1 3 6 1 4 1 674 10892 1 1500 20 Description Defines the LRA Action Table Syntax SEQUENCE OF LRAActionTableTableE ntry Access Not accessible LRA Action Table Entry Name LRAActionTableTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 Description Defines the LRA Action Table entry Syntax LRAActionTableTableE ntry Access Not accessible Index IRAActionTablechassisl ndex IRAActionTableActionN umberl ndex LRA Action Table Chassis Index Name 1RAActionTablechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 432 Local Response Agent Group LRA Action Table Action Number Index Name Object ID Description Syntax Access 1RAActionTableActionNumberIndex 1 3 6 1 4 1 674 10892 1 1500 20 1 2 Defines the LRA action number index
346. ess Read only Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 52 Description Identifies the patrol read mode Possible values 1 Automatic enabled 2 M anual enabled 3 Disabled Syntax Integer Access Read only 578 Storage Management Group Controller Patrol Read State Name Object ID Description Syntax Access controllerPatrolReadState 1 3 6 1 4 1 674 10893 1 20 130 1 1 53 The state of the patrol read Possible values 1 Stopped not running 2 Ready ready to start 4 Active is running 8 Aborted has aborted Integer Read only Controller Patrol Read Iterations Name Object ID Description Syntax Access controllerPatrolReadIterations 1 3 6 1 4 1 674 10893 1 20 130 1 1 54 The number of times Patrol Read has been run on this controller Integer Read only Controller Storport Driver Version Name Object ID Description Syntax Access controllerStorportDriverVersion 1 3 6 1 4 1 674 10893 1 20 130 1 1 55 Provides current W indows OS storport driver version Not applicable for Linux Octet String Read only Storage Management Group 579 Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 56 Description Provides minimum required storport driver version for W indows OS only Syntax Octet String Access Read only Control
347. essor Port Table entry Syntax ProcessorPortT ableE ntry Access Not accessible Index processorPortchassisl ndex processorPort ndex Processor Port Chassis Index Name processorPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only PortGroup 233 Processor Port Index Name processorPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 2 Description Defines the index of the processor ports in this chassis Syntax DellO bjectRange Access Read only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 3 Description Defines the capabilities of the processor port Syntax D ellStateC apabilities Access Read only Processor Port State Settings Name processorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 4 Description Defines the state and settings of the processor port Syntax DellStateSettings Access Read write Processor Port Status Name processorPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 5 Description Defines the status of the processor port Syntax DellStatus Access Read only 234 Port Group Processor Port Security State Name Object ID Description Syntax Access processorPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 30 1 6 Defines the security settings of the processor port D ellPortSecurityState R
348. essor family is Intel C ore2 ile 196 Duo mobile processor deviceFamilyIsIntelCore2SoloMo The processor family is Intel C ore2 bile 197 Solo mobile processor deviceFamilyIsIntelCorei7 198 The processor family is Intel Core i7 processor deviceFamilyIsDualCoreIntelCel Theprocessor family is D ual C ore Intel eron 199 Celeron Processor deviceFamilyIsIBM390 200 The processor family is IBM 390 deviceFamilyIsG4 201 The processor family is G 4 deviceFamilyIsG5 202 The processor family is G5 deviceFamilyIsESA390G6 203 The processor family is ESA 390 G6 deviceFamilyIszArchitectur The processor family is z Architectur 204 base deviceFamilyIsIntelCorei5 205 The processor family is Intel Corei5 processor deviceFamilyIsIntelCorei3 206 The processor family is Intel C ore i3 processor deviceFamilyIsVIAC7 M 210 The processor family is VIA C7 M deviceFamilyIsVIAC7 D 211 The processor family is family is VIA C7 D deviceFamilyIsVIAC7 212 The processor family is VIA C7 deviceFamilyIsVIAEden 213 The processor family is VIA Eden deviceFamilyIsMultiCoreIntelXe The processor family is M ulti C ore on 214 Intel Xeon processor 332 Device Group Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo n3xxx 215 The processor family is D ual C ore Intel Xeon
349. ettings Variable Name De 11 LEDControlSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 TheLED control setting is unknown alertOnError 2 TheLED control is set to alert on an error condition alertOnWarningAndError 4 TheLED control is set to alert on an error or a warning condition Table 6 7 Hard Drive Fault LED Control Capabilities Variable Name De 1 1HDFaultLEDControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The hard drive has no fault LED capabilities unknownCapabilities 1 The hard drive fault LED capabilities are unknown enableCapable 2 The hard drive fault LED can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The hard drive fault LED can indicate not ready resetCapable 8 The hard drive fault LED can be reset Chassis Information Group 111 Table 6 8 Hard Drive Fault LED Control Settings Variable Name De 1 1HDFault LEDControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any fault settings capabilities unknown 1 The hard drive fault LEDs state is unknown enabled 2 The hard drive fault LEDs state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The hard drive
350. eviceTableEntry Not accessible DeviceGroup 277 Cache Device Table Entry Name Object ID Description Syntax Access Index cacheDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 40 1 Defines the Cache Device Table entry CacheD eviceTableE ntry Not accessible cacheD evicechassis ndex cacheD evicel ndex Cache Device Chassis Index Name Object ID Description Syntax Access cacheDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 40 1 1 Defines the index one based of this chassis DellO bjectRange Read only Cache Device Index Name Object ID Description Syntax Access cacheDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 40 1 2 Defines the index of the cache device in this chassis DellO bjectRange Read only Cache Device State Capabilities Name Object ID Description Syntax Access cacheDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 40 1 3 Defines the capabilities of the cache device DellStateC apabilities Read only 278 Device Group Cache Device State Settings Name Object ID Description Syntax Access cacheDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 40 1 4 Defines the state of the cache device DellStateSettings Read write Cache Device Status Name Object ID Description Syntax Access cacheDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 40 1 5 Defines the status of the cache device DellStatus Read only Cache Device Processor Device Index Reference
351. ex Name aCPowerCordIndex Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 2 Description Defines the index one based of this AC power cord Syntax DellObjectRange Access Read only AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 3 Description Defines the capabilities of this AC power cord Syntax DellAC PowerC ordStateC apabilities Access Read only 172 Power Group AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 4 Description Defines the settings of this AC power cord Syntax DellAC PowerC ordStateSettings Access Read write AC Power Cord Status Name aCPowerCordStatus Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 5 Description Defines the status of this AC power cord Syntax DellStatus Access Read only AC Power Cord AC Power Switch Index Reference Name Object ID Description Syntax Access aCPowerCordaCPowerSwitchIndexReference 1 3 6 1 4 1 674 10892 1 600 42 1 6 Defines the index one based to the associated AC power switch for this AC power cord DellObjectRange Read only AC Power Cord Location Name Name Object ID Description Syntax Access aCPowerCordLocationName 1 3 6 1 4 1 674 10892 1 600 42 1 7 Defines the location name of this AC power cord DellString Read only 173 Power Group 174 Battery Table Name Object ID Description Syntax Access Battery Tabl
352. f set to 0 zero There are no redundant memory capabilities unknownCapabilities 1 Redundant capabilities are unknown The redundant capabilities are spareCapable 2 Spare redundant memory feature is supported mirrorCapable 4 M irror redundant memory feature is supported spareAndMirrorCapable 6 Spare and mirror redundant memory features are supported raidCapable 8 Redundant Array of Independent disks RAID redundant memory feature is supported dddcCapable 16 DDDC redundancy is supported MemoryGroup 385 Table 16 6 Physical Memory Configuration Redundant Settings Variable Name DellPhysicalMemoryConfigRedundantSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero Thereareno redundant memory settings enabled unknown 1 Redundant settings are unknown The following redundant settings are mutually exclusive spareEnabled 2 Spare redundant memory feature is enabled mirrorEnabled 4 Mirror redundant memory feature is enabled raidEnabled 8 RAID redundant memory feature is enabled dddcCapable 16 DDDC redundancy is enabled Table 16 7 Physical Memory Logging Capabilities Variable Name De 1 1 PhysicalMemoryLoggingCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no logging capabilities unknown Capabilities 1 Logging capabilities a
353. fault LEDs state is not ready reset 8 The hard drive fault LEDs have been reset resetAndEnable 10 The hard drive fault LEDs have been reset and enabled Table 6 9 Chassis Identification Control Capabilities Variable Name De11ChassisIdentifyControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any chassis identification capabilities unknownCapabilities 1 The chassis identification control s capabilities are unknown enableCapable 2 The chassis identification controls can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The chassis identification control s capabilities are not ready identifyCapable 8 112 Chassis Information Group The chassis identification control s LEDs can be made to identify the chassis Table 6 9 Chassis Identification Control Capabilities continued Variable Name De11ChassisIdentifyControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value NOTE Chassis identification capabilities allow system administrators to set front panel light emitting diodes LEDs to blink when the chassis has malfunctioning components When enabled the blinking lights help administrators locate the problem chassis Table 6 10 Chassis Identification Control Settings Variable Name De11Chassis
354. figuration Trap Group The trap subgroups and all the traps within each trap subgroup are described and listed in sections following the Trap Variables section K NOTE The traps listed in this document can be correlated to specific events that are documented in the Dell Event Message Reference guide There is 1 to many relationship between SNMP traps and events in iDRAC7 To correlate a trap to a specific event or set of events you can match the Trap ID value of a trap in this document to the Trap Event ID value of events in the Dell Event M essage Reference guide Trap Variables This section lists the six variables that are sent with iD RAC 7 traps to provide additional information about atrap or alert generated by some event on the system T he trap variables presented here apply to all iD RAC 7 traps The trap variables are sent in the order listed and are reserved for use only in traps iDRAC7MIB 747 Alert Message ID Variable Name alertMessageID Object ID 1 3 6 1 4 1 674 10892 5 3 1 1 0 Description M essage ID of the event Syntax DisplayString SIZE 0 8 Alert Message Variable Name alertMessage Object ID 1 3 6 1 4 1 674 10892 5 3 1 2 0 Description M essage describing the alert Syntax StringType Alert Current Status Variable Name alertCurrentStatus Object ID 1 3 6 1 4 1 674 10892 5 3 1 3 0 Description Current status of object causing the alert if applicable Syntax ObjectStatusE num Alert System Ser
355. fines the bitmap of supported methods for firmware update Syntax D ellU nsigned16BitR ange Access Read only Firmware Date Name Name firmwareDateName Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 10 Description Defines the date of the firmware Syntax D ellD ateN ame Access Read only 100 Chassis Information Group Firmware Version Name Name Object ID Description Syntax Access firmwareVersionName 1 3 6 1 4 1 674 10892 1 300 60 1 11 Defines the version name of the firmware DellString Read only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion a situation that occurs when the cover of a computer is removed Name Object ID Description Syntax Access intrusionTable 1 3 6 1 4 1 674 10892 1 300 70 Defines the Intrusion Table SEQUENCE OF IntrusionTableEntry Not accessible Intrusion Table Entry Name Object ID Description Syntax Access Index intrusionTableEntry 1 3 6 1 4 1 674 10892 1 300 70 1 Defines the Intrusion Table entry IntrusionTableE ntry Not accessible intrusionchassisI ndex intrusion ndex Intrusion Chassis Index Name Object ID Description Syntax Access intrusionchassisIndex 1 3 6 1 4 1 674 10892 1 300 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Chassis Information Group 101 Intrusion Index Name int rusionIndex Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 2 Descriptio
356. first byte returned represents the status of the first SD Card unit and so on The bytes have the same definition type as D ellStatus Octet String Size 1 128 Read only System State SD Card Device Status Combined Name Object ID Description systemStateSDCardDeviceStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 56 Defines the combined status of all SD Card devices of this chassis 69 System State Group Name systemStatesSDCardDeviceStatusCombined Syntax DellStatus Access Read only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 57 Description Lists the status of each SD Card device of this chassis T he results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device The first byte returned represents the status of the first SD C ard device and so on The bytes have the same definition type as D ellStatus Syntax Octet String Size 1 128 Access Read only 70 System State Group Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system as well as information about the light emitting diode LED indicators and settings for devices on each chassis Information is also available about the current date and time displayed on the chassis intrusion warnings watchdog timer systems management basic input output sy
357. from the specified system for a user definable length of time T he sensor location and chassis location are provided Traps 713 AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord AC power cord traps provide status and warning information for power cords that are part of an AC power switch if your system supports AC switching Table 27 12 AC Power Cord Traps TrapID Description Severity Cause AC Power Cord No Power Non redundant 1501 AC power cord is not being monitored Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Information TheAC power cord status is not being monitored This occurs when a system s expected AC power configuration is set to nonredundant T he sensor location and chassislocation information are provided AC Power Cord Normal 1502 AC power has been restored Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Information An AC power cord that did not have AC power has had the power restored The sensor location and chassis location information are provided AC Power Cord Failure 1504 AC power has been lost Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Error An AC power cord has lost its power T he sensor location and chassis location information are provided 714
358. g system memory events The following object sets up the Physical Memory Logging Table Name physicalMemoryLoggingTable Object ID 1 3 6 1 4 1 674 10892 1 1300 40 Description Defines the Physical Memory Logging Table Syntax SEQUENCE OF PhysicalM emoryL oggingTableE ntry Access Not accessible Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1300 40 1 Description Defines the Physical Memory Logging Table entry Syntax PhysicalM emoryL oggingT able ntry Access Not accessible Index physicalM emoryL oggingC hassis ndex physicalM emoryL oggingl ndex 374 Memory Group Physical Memory Logging Chassis Index Name Object ID Description Syntax Access physicalMemoryLoggingChassisIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 1 Defines the index one based of the chassis associated with the physical memory logging DellO bjectRange Read only Physical Memory Logging Index Name Object ID Description Syntax Access physicalMemoryLoggingIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 2 Defines the index one based of the physical memory logging DellO bjectRange Read only Physical Memory Logging Capabilities Name Object ID Description Syntax Access physicalMemoryLoggingCapabilities 1 3 6 1 4 1 674 10892 1 1300 40 1 3 Defines the capabilities of the physical memory logging DellPhysicalM emoryL oggingC apabilities Read only Physical Memory Log
359. ge Access Read only FRU Index Name fruIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 2 Description Defines the index one based of the FRU Syntax DellO bjectRange Access Read only FRU Information Status Name fruInformationStatus Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 3 Description Defines the status of the FRU table entry Syntax DellStatus Access Read only FRU Information State Name fruInformationState Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 4 Description Definesthe state of the FRU information Some information for the FRU may not be available if the state is other than ok 1 Syntax DellF RUInformationState Access Read only 548 Field Replaceable Unit Group FRU Device Name Name fruDeviceName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 5 Description Defines the device name of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturer Name Name fruManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 6 Description Defines the manufacturer of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Serial Number Name Name fruSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 7 Description Defines the serial number of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Part Number Name Name fruPartNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 8 Description Defines the part number of the FRU Syntax DisplayStr
360. ge Read only System Resource Group 143 System Resource DMA Index Name systemResourceDMAIndex Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 2 Description Defines the index of system resource D M Asin this chassis Syntax DellO bjectRange Access Read only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 3 Description Defines the capabilities of this system resource DM A Syntax D ellStateC apabilities Access Read only System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 4 Description Defines the state and setting of this system resource DM A Syntax DellStateSettings Access Read write System Resource DMA Status Name systemResourceDMAStatus Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 5 Description Defines the status of this system resource DMA Syntax DellStatus Access Read only 144 System Resource Group System Resource DMA Owner Index Reference Name Object ID Description Syntax Access systemResourceDMAOwnerIndexReferenc 1 3 6 1 4 1 674 10892 1 500 60 1 6 Defines the index to the associated system resource owner in this chassis DellO bjectRange Read only System Resource DMA Share Disposition Name Object ID Description Syntax Access systemResourceDMAShareDisposition 1 3 6 1 4 1 674 10892 1 500 60 1 7 Defines the share disposition of the
361. ge Management Group Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 11 Description Indicates whether the controller s read cache are used when reading from a virtual disk Possible values 1 Enabled Adaptec Read Cache Enabled 2 Disabled Adaptec Read C ache Disabled 3 LSI Read Ahead 4 LSI Adaptive Read Ahead 5 LSI No Read Ahead 9 Not Applicable Syntax Integer Access Read only Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 12 Description Indicates whether the controller s cache is used when reading from or writing to a virtual disk Possible values 1 Direct I O LSI 2 Cached 1 0 LSI 99 Not Applicable Syntax Integer Access Read only Storage Management Group 661 Virtual Disk Layout Name virtualDiskLayout Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 13 Description Indicates the virtual disk s RAID type Possible values 1 Concatenated 2 RAID 0 3 RAID 1 7 RAID 5 8 RAID 6 10 RAID 10 12 RAID 50 19 Concatenated RAID 1 24 RAID 60 Syntax Integer Access Read only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 14 Description Identifies the stripe size of this virtual disk in megabytes If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only 662 l Storage M anagement Group Virtua
362. gement Module Connection Enclosure Number Name enclosureManagementModuleConnectionEnclosure Number Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs Syntax Integer Access Read only Storage Management Group 647 Battery Table This table describes available properties for each controller battery on the managed system The following object sets up the Battery Table Name batteryTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 Description D efines the battery table Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 Description D efines the battery table entry Syntax BatteryE ntry Access Not accessible Index batteryN umber Battery Number Name batteryNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 1 Description Identifies the instance number of the battery entry Syntax Integer Access Read only 648 Storage Management Group Battery Name Name batteryName Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 2 Description Identifies the battery s name as represented in Storage Management Syntax DisplayString Access Read only Battery Vendor Name batteryVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 3 Description Identifies the battery s re seller s name Syntax DisplayString Access
363. ging Settings Name Object ID Description Syntax Access physicalMemoryLoggingSettings 1 3 6 1 4 1 674 10892 1 1300 40 1 4 Defines the settings of the physical memory logging DellPhysicalM emoryL oggingSettings Read write MemoryGroup 375 Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 40 1 5 Description Defines the status of the physical memory logging Syntax DellStatus Access Read only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis The following object sets up the Redundant M emory Unit Table Name redundantMemoryUnitTable Object ID 1 3 6 1 4 1 674 10892 1 1300 50 Description Defines the Redundant M emory Unit Table Syntax SEQUENCE OF RedundantM emoryU nitTableE ntry Access Not accessible 376 Memory Group Redundant Memory Unit Table Entry Name Object ID Description Syntax Access Index redundantMemoryUnitTableEntry 1 3 6 1 4 1 674 10892 1 1300 50 1 Defines the Redundant M emory Unit Table entry RedundantM emoryU nitTableE ntry Not accessible redundantM emoryU nitC hassisl ndex redundantM emoryU nitl ndex Redundant Memory Unit Chassis Index Name Object ID Description Syntax Access redundantMemoryUnitChassisIndex 1 3 6 1 4 1 674 10892 1 1300 50 1 1 Defines the index one based of the chassis associated with the redundant memory unit Del
364. gradelIsByLIFSocket 7 Upgrade device is in a low insertion force LIF socket processor UpgradeIsBySlotl 8 Upgrade device isaSLOT 1 processor processor UpgradeIsBySlot2 9 Upgrade device isa SLOT 2 processor processor UpgradeIsBy370PinSocket 10 Upgrade device is a 370 pin socket processor UpgradeIsBySlotA 11 Upgrade is by Slot A processor UpgradeIsBySlotM 12 Upgrade is by Slot M processor UpgradelIsByScoket423 13 Upgrade is by Socket 423 processor UpgradelIsBySocketA 14 Upgrade is by Socket A Socket 462 processor UpgradelIsBySocket478 15 Upgrade is by Socket 478 processor UpgradelIsBySocket754 16 Upgrade is by Socket 754 processor UpgradelIsBySocket 940 17 Upgrade is by Socket 940 Device Group 323 Table 14 5 Processor Upgrade Information continued Variable Name De 1 1ProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket 939 18 Upgrade is by Socket 939 processorUpgradeIsBySocketmPGA604 19 Upgrade is by Socket mPG A604 processorUpgradeIsBySocketLGA771 20 Upgrade is by Socket LGA771 processorUpgradeIsBySocketLGA775 21 Upgrade is by Socket LGA775 processorUpgradelIsBySocketS1 22 Upgrade is by Socket S1 processorUpgradeIsBySocketAM2 23 Upgrade is by Socket AM 2 p
365. hannel is not supported in Storage M anagement Integer Read only Controller Fault Tolerant Name Object ID Description Syntax Access controllerFaultTolerant 1 3 6 1 4 1 674 10893 1 20 130 1 1 18 This entry is obsolete Fibre channel is not supported in Storage Management Integer Read only Controller CO Port 0 World Wide Name Name Object ID Description Syntax Access controllerCOPort0WorldWideName 1 3 6 1 4 1 674 10893 1 20 130 1 1 19 This entry is obsolete Fibre channel is not supported in Storage Management DisplayString Read only Controller CO Port 0 Name Name Object ID Description Syntax Access controllerCOPort0Name 1 3 6 1 4 1 674 10893 1 20 130 1 1 20 This entry is obsolete Fibre channel is not supported in Storage M anagement DisplayString Read only Storage Management Group 569 Controller CO Port 0 ID Name controllerCOPort0ID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 21 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax Integer Access Read only Controller CO Target Name controllerC0OTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 22 Description This entry is obsolete Fibre channel is not supported in Storage M anagement Syntax Integer Access Read only Controller CO Channel Name controllerCOChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 23 Description This entry is obsolete
366. has for this system Syntax DellC ostofO wnershipString Access Read write COO Outsourcing Problem Description Name Name cooOutsourcingProblemDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 23 Description Defines a problem encountered with the outsourcing service provider Syntax DellC ostofO wnershipString Access Read write Costof Ownership Group 443 COO Outsourcing Service Fee Name Name Object ID Description Syntax Access cooOutsourcingServiceFeeName 1 3 6 1 4 1 674 10892 1 1600 10 1 24 Defines amount that the outsourcing vendor charges for service DellC ostofO wnershipString Read write COO Outsourcing Signing Authority Name Name Object ID Description Syntax Access cooOut sourcingSigningAuthorityName 1 3 6 1 4 1 674 10892 1 1600 10 1 25 Defines the name of the person who can sign the authorization for service DellC ostofO wnershipString Read write COO Outsourcing Provider Fee Name Name Object ID Description Syntax Access cooOutsourcingProviderFeeName 1 3 6 1 4 1 674 10892 1 1600 10 1 26 Defines any additional outsourcing charge for service DellC ostofO wnershipString Read write COO Outsourcing Provider Service Level Name Name Object ID Description Syntax Access cooOutsourcingProviderServiceLevelNam 1 3 6 1 4 1 674 10892 1 1600 10 1 27 Defines the service level agreement for the system DellC ostofO wnershipString Read write 444 Cost of Ownersh
367. hassis management card processor Syntax DellTemperatureReading Access Read only DRsGlobalPrevStatus Name DRsGlobalPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 1 Description Defines the previous chassis status recorded by the chassis management card Syntax DellStatus Access Read only Dell Remote Access Controller Out of BandGroup 699 DRsIOMPrevStatus Name DRslOMPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 2 Description Defines the previous IOM subsystem status recorded by the chassis management card Syntax DellStatus Access Read only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 3 Description Defines the previousiKVM subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only DRsRedPrevStatus Name DRsRedPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 4 Description Defines the previous redundancy status recorded by the chassis management card Syntax DellStatus Access Read only 700 Dell Remote Access Controller Out of Band Group DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 5 Description Defines the previous power subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 6 Description Defines the previous fan health status being monitored by the cha
368. hat the image size of the BIOS is unknown Syntax DellUnsigned32BitRange Access Read only System BIOS Release Date Name Name systemBIOSReleaseDateNam Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 7 Description Defines the release date of the system BIOS Syntax DellDateName Access Read only System BIOS Version Name Name systemBIOSVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 8 Description Defines the version name of the system BIOS Syntax DellString Access Read only System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 9 Chassis Information Group 93 Name systemBIOSStartingAddress Description D efines the starting address of the system BIOS A zero 0 indicates that the address is unknown Syntax D ellU nsigned64BitR ange Access Read only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 10 Description Defines the ending address of the system BIOS A zero 0 indicates that the address is unknown Syntax D ellU nsigned64BitR ange Access Read only System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 11 Description Defines the system BIOS manufacturer s name Syntax DellString Access Read only System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 12 94 Chassis Information Group
369. he M IBs that NA support Server Administrator services 26 Traps describes in band traps defined in the Server 5000 Administrator Instrumentation MIB and out of band traps sent by the Remote Access Controller RAC and Baseboard M anagement Controller BMC AppendixA Standard Data Type Definitions defines standard NA data types used in this reference guide AppendixB SNMP Sample Output providesasampleSNMP NA output Server Administrator Instrumentation MIB The Server Administrator Instrumentation M IB filename 10892 mib provides instrumentation data that allows you to monitor the health of a system with SNM P management applications It provides e Information about the status of temperatures power supplies voltages currents fans and memory at key points in the system e Rapid access to detailed fault and performance information gathered by industry standard systems management agents e Version information for Basic Input Output System BIOS firmware and operating system 18 Introduction A detailed account of every cost of ownership COO detail about your system In addition traps are sent to report a change in status of the health of critical components The Server Administrator Instrumentation M IB structures its M IB objects into groups of scalar objects or M IB tables that provide related information Table 1 2 describes each Server Administrator Instrumentation M IB group and lists
370. he index to the associated SD Card unit if the SD Card device is part of aSD Card unit Syntax DellO bjectRange Access Read only Device Group 319 SD Card Device Card Available Storage Size Name Object ID Description Syntax Access sdCardDeviceCardAvailableStorageSize 1 3 6 1 4 1 674 10892 1 1100 112 1 12 Defines the available storage size in M B megabytes of the SD card for the SD card device DellSigned32BitRange Read only SD Card Device Card Licensed Name Object ID Description Syntax Access sdCardDeviceCardLicensed 1 3 6 1 4 1 674 10892 1 1100 112 1 13 Defines whether the SD card is licensed by the system vendor DellSDC ardD eviceC ardLicensed Read only Device Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 14 1 Pointing Device Type Variable Name De 1 1PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypeIsUnknown 2 Device type is unknown deviceTypelIsAMouse 3 Device type is a mouse deviceTypelIsATrackBall 4 Device type is a track ball deviceTypelIsATrackPoint 5 Device type is a track point deviceTypeIsAGlidePoint 6 Device type is a glide point 320 Device Group Table 14 1 Pointing Device Type continued Variable Name De11PointingDevi
371. he state of the critical components supported by your system Components monitored under the System State Group include power supplies AC power cords AC power switches and cooling devices as well as temperature fan amperage and voltage probes System State Group Table The System State Group defines objects in the System State M IB table System State Table T he systemStateG lobalSystem Status variable provides overall system health status and includes rolled up that is worst status for Instrumentation and Storage T his variable monitors the overall system health status It reflects changes to systemStateC hassisStatus variable which represents Instrumentation health status and agentG lobalSystem Status dcstorag mib which represents Storage health status T he system StateC hassisStatus variable provides the rolled up health status for the subsystems associated with the chassis that is represented by the row in the systemStateTable C hanges to the variables in List 1 on page 50 each of which indicates the rolled up health status of all the components of the corresponding subsystem are reflected in systemStateC hassisStatus variable For example systemStatePowerSupplyStatusC ombined provides the rolled up status of all power supplies for the chassis The variables in List 2 on page 50 provide the health status of each component of the corresponding subsystem Each octet of the value represents a component If a power
372. hs 4 Duration time type isin months Table 19 4 COO Month Year Duration Type Variable Name Del 1CooMonthYearDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown months 4 Duration time type isin months years 5 Duration time type is in years Cost of Ownership Group 469 470 Cost of Ownership Group Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system In addition to providing general information about the capabilities and settings of the remote access hardware this group provides information about administrative users SNMP trap destinations modem configuration for dial up networking dial in configuration and dial out destinations DRAC 4 and DRAC 5 On systems with Dell Remote Access Controller DRAC 40r DRAC 5 the Remote Access Group includes only the Remote Access Table Remote Access Table The following M IB object sets up the Remote Access Table Name remoteAccessTabl Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableE ntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableE ntry Access Not accessible In
373. ialPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 3 Description Defines the capabilities of the serial port Syntax D ellStateC apabilities Access Read only Serial Port State Settings Name serialPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 4 Description Defines the state and settings of the serial port Syntax DellStateSettings Access Read write PortGroup 249 Serial Port Status Name serialPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 5 Description Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Security State Name serialPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 6 Description Defines the security settings of the serial port Syntax DellPortSecurityState Access Read only Serial Port Connector Type Name serialPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 7 Description Defines connector type of the serial port Syntax D ellSerialPortC onnectorType Access Read only Serial Port Name Name serialPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 8 Description Defines the name of the serial port Syntax DellString Access Read only 250 Port Group Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 9 Description Defines the maximum speed the serial interface can support in bits per second bps Syntax D ellU nsigned32BitR ange Access Re
374. icalMemoryConfigTableEntry 1 3 6 1 4 1 674 10892 1 1300 30 1 Defines the Physical Memory Configuration Table entry PhysicalM emoryC onfigTableE ntry Not accessible physicalM emoryC onfigC hassisIndex physicalM emoryC onfigl ndex MemoryGroup 371 Physical Memory Configuration Chassis Index Name Object ID Description Syntax Access physicalMemoryConfigChassisIndex 1 3 6 1 4 1 674 10892 1 1300 30 1 1 Defines the index one based of the chassis associated with the physical memory configuration DellO bjectRange Read only Physical Memory Configuration Index Name Object ID Description Syntax Access physicalMemoryConfigIndex 1 3 6 1 4 1 674 10892 1 1300 30 1 2 Defines the index one based of the physical memory configuration DellO bjectRange Read only Physical Memory Configuration State Capabilities Name Object ID Description Syntax Access physicalMemoryConfigStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 3 Defines the state capabilities of the physical memory configuration DellPhysicalM emoryC onfigStateC apabilities Read only Physical Memory Configuration State Settings Name Object ID Description Syntax Access 372 physicalMemoryConfigStateSettings 1 3 6 1 4 1 674 10892 1 1300 30 1 4 Defines the state settings of the physical memory configuration DellPhysicalM emoryC onfigStateSettings Read write Memory Group Physical Memory Configuration Status Nam
375. ice DellC acheD eviceE C C Type See Table 14 11 Read only Cache Device Associativity Name Object ID Description Syntax Access cacheDeviceAssociativity 1 3 6 1 4 1 674 10892 1 1100 40 1 18 Defines the type of associativity in use by the cache device DellC acheD eviceAssociativity See Table 14 12 Read only Cache Device Supported Type Name Object ID Description Syntax Access 282 cacheDeviceSupportedType 1 3 6 1 4 1 674 10892 1 1100 40 1 19 Defines the type of static random access memory SRAM that the cache device can support DellC acheD eviceSupportedType Read only Device Group Cache Device Current Type Name Object ID Description Syntax Access cacheDeviceCurrentTyp 1 3 6 1 4 1 674 10892 1 1100 40 1 20 Defines the current type of SRAM for the cache device DellC acheD eviceSRAM Type See Table 14 14 Read only Memory Device Table Name Object ID Description Syntax Access memoryDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 50 Defines the M emory Device Table SEQUENCE OF MemoryD eviceTableE ntry Not accessible Memory Device Table Entry Name Object ID Description Syntax Access Index memoryDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 50 1 Defines the M emory D evice Table entry M emoryD eviceTableE ntry Not accessible memoryD evicechassisl ndex memoryD evicelndex Memory Device Chassis Index Name Object ID Description Syntax Acce
376. ice Status Table on page 275 e Cache Device Table on page 277 e Memory Device Table on page 283 Memory Device M apped Address Table on page 291 e Generic Device Table on page 294 PCI Device Table on page 297 e PCI Device Configuration Space Table on page 300 e Network Device Table on page 303 e Managed System Services D evice Table on page 311 SD Card Unit Table on page 313 SD Card Device Table on page 316 Device Group 261 Pointing Device Table Name Object ID Description Syntax Access pointingDeviceTable 1 3 6 1 4 1 674 10892 1 1100 10 Defines the Pointing Device Table This group of objects references the Pointing Port Index See Section 12 SEQUENCE OF PointingD eviceTableEntry Not accessible Pointing Device Table Entry Name Object ID Description Syntax Access Index pointingDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 10 1 Defines the Pointing D evice Table entry PointingD eviceTableE ntry Not accessible pointingD evicechassisl ndex pointingD evicel ndex Pointing Device Chassis Index Name Object ID Description Syntax Access pointingDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 1 Defines the index one based of this chassis DellO bjectRange Read only Pointing Device Index Name Object ID Description Syntax Access pointingDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 2 Defines the index of the pointing device in this chassis
377. ices Group Storage Management Event Group 27 Storage M anagement Alert Reference lets you monitor the NA health of storage resources such as controllers connectors array disks and virtual disks Server Administrator Change Management MIB The Server Administrator C hange M anagement M IB filename dellcm mib provides management data that allows you to monitor the inventory of devices and applications with SNM P management applications Table 1 6 describes each Server Administrator C hange M anagement M IB group and liststhe M IB group number assigned to the M IB group T he Server Administrator Change M anagement M IB groups are identified by the SNM P OID 1 3 6 1 4 1 674 lt M IB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the M IB objects defined in a M IB group Table 1 6 Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change M anagement Group describes the inventory data 10899 provided by the C hange M anagement M IB that allows users to monitor devices and software present on a particular managed computer chassis Introduction 23 Dell Remote Access Controller Out of Band MIB The Dell Remote Access C ontroller Out of Band M IB filename delIRAC mib provides management data that allows you to monitor the Chassis M anagement C ontroller T
378. ies Name sdCardUnitStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 3 Description Defines the state capabilities of the SD Card unit Syntax DellStateC apabilities Access Read only SD Card Unit State Settings Name sdCardUnitStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 4 314 Device Group Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit Syntax DellStateSettings Access Read only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 5 Description Defines the redundancy status of the SD Card unit Syntax DellStatusR edundancy Access Read only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy Syntax DellO bjectRange Access Read only SD Card Unit Name Name sdCardUnitName Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 7 Description Defines the name of the SD Card unit Syntax DellString Access Read only DeviceGroup 315 SD Card Unit Status Name sdCardUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 8 Description Defines the status of the SD Card unit Syntax DellStatus Access Read only SD Card Device Table Name sdCardDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 112 Description Defines
379. ileTableEntry Access Not accessible Index powerProfileC hassisIndex powerProfilel ndex Power Profile Chassis Index Name powerProfileChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Power Profile Index Name powerProfileIndex Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 2 Description Defines the index one based of the power profile information Syntax DellObjectRange Access Read only Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 3 Description Defines the supported power profiles Syntax DellPowerProfileType Access Read only Power Profile Setting Name powerProfileSetting Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 4 Description Defines the power profile setting 183 Power Group Name Syntax Access powerProfileSetting DellPowerProfileType Read only Power Profile Custom CPU Management Capabilities Name Object ID Description Syntax Access powerProfileCustomCPUManagementCapabilities 1 3 6 1 4 1 674 10892 1 600 70 1 5 Defines the custom C PU power and performance management capabilities that are available for the C ustom power profile DellC PU PowerPerformanceM anagementType Read only Power Profile Custom CPU Management Setting Name Object ID Description Syntax Access powerProfileCustomCPUManag
380. in the variable name e Acronyms are in uppercase letters except when an acronym is the first word in the variable name e With the exception of the first letter of the variable name and acronyms all other words in the variable name start with capital letters The following variable names illustrate these conventions e temperatureProbel owerC riticalT hreshold e coolingU nitlndex e pCIDeviceSpeed O bject Identifier 01D is the unique number assigned to an object defined in a MIB An OID is written as a sequence of subidentifiers in decimal notation Each OID in this reference guide has a prefix that identifies the managed objects as belonging to Dell 1 3 6 1 4 1 674 The additional numbers identify the M IB group and subgroup as well as the table entry number of any variables For example the OID for the temperature probe managed object table is 700 20 and the variable for the location of the temperature probe temperatureProbeL ocationN ame has an OID of 700 20 1 8 The full OIDs for these items are 1 3 6 1 4 1 674 10892 1 700 20 for the temperatureProbeTable and 1 3 6 1 4 1 674 10892 1 700 20 1 8 for the temperatureProbeL ocation For more information about the structure of OIDs see SNM P Management Information Base O bject Identifiers on page 35 Introduction 27 Description is a brief explanation of what a particular managed object does Syntax defines the data type in which the values of the variable must be expres
381. inEmailCustomMessageName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 28 Description Defines the e mail message to send to this remote access user Syntax DisplayString SIZE 0 31 Access Read write 494 Remote Access Group Remote User Admin Control Capabilities Name Object ID Description Syntax Access remoteUserAdminControlCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 29 Defines the control capabilities for this remote access user DellRemoteU serAdminC ontrolC apabilities See Table 20 14 on page 517 Read only Remote User Admin Control Settings Name Object ID Description Syntax Access remoteUserAdminControlSettings 1 3 6 1 4 1 674 10892 1 1700 20 1 30 Defines the control settings for this remote access user DellRemoteU serAdminC ontrolSettings See Table 20 15 Read write Remote User Admin User Type Name remot eUserAdminUserType Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 31 Description Defines the type of user for this remote access user Syntax DellU nsigned8BitRange Access Read write Remote SNMP Trap Table Name remoteSNMPTrapTable Object ID 1 3 6 1 4 1 674 10892 1 1700 30 Description Defines the Remote Access SNM P Trap Destination Table Syntax SEQUENCE OF RemoteSNM PTrapTableEntry Access Not accessible Remote Access Group 495 Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 Description Defines the Remote Access SNM
382. ines the DRS events filter capabilities for this remote access user DellU nsigned32BitRange Read only Remote User Admin Alert Filter System Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterSysCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 14 Defines the system events filter capabilities for this remote access user DellUnsigned32BitRange Read only Remote User Admin Pager Numeric Number Name Name Object ID Description Syntax Access remot eUserAdminPagerNumericNumberName 1 3 6 1 4 1 674 10892 1 1700 20 1 15 Defines the numeric pager number for this remote access user DisplayString SIZE 0 95 Read write Remote User Admin Pager Numeric Message Name Name Object ID Description Syntax Access remoteUserAdminPagerNumericMessageNam 1 3 6 1 4 1 674 10892 1 1700 20 1 16 Defines the message to send to the numeric pager for this remote access user DisplayString SIZE 0 31 Read write Remote Access Group 491 Remote User Admin Pager Numeric Hang up Delay Name remot eUserAdminPagerNumericHangupDelay Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 17 Description Defines the numeric pager hang up delay for this remote access user Syntax DellU nsigned32BitRange Access Read write Remote User Admin Pager Alpha Phone Number Name Name remot eUserAdminPagerAlphaPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 18 Description Defines the alphanu
383. ines the URL for launching the Remote Access Remote Connect Interface Syntax DisplayString SIZE 0 63 Access Mandatory DRAC Ill On systems with DRAC III the Remote Access Group includes the following M IB tables Remote Access Table on page 478 Remote U ser Administration Table on page 487 Remote SNM P Trap Table on page 495 Remote Dial Up Table on page 500 Remote User Dial In Configuration Table on page 504 Remote Dial O ut Table on page 507 Remote Access Group 477 Remote Access Table The following M IB object sets up the Remote Access Table Name remoteAccessTabl Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableE ntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableE ntry Access Not accessible Index remoteAccessC hassisl ndex remoteAccessA dapter ndex Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remot
384. ines the state settings of this remote access dial up functionality Syntax DellRemoteD ialU pStateSettings See Table 20 23 Access Read write Remote Access Group 501 Remote Dial Up Status Name remoteDialUpStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 6 Description Defines the status of this remote access dial up functionality Syntax DellStatus Access Read only Remote Dial Up PPP Dial In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 7 Description Defines the base IP address of the PPP server for this remote access dial up functionality Syntax pAddress Access Read write Remote Dial Up PPP Dial In Idle Time out Name remoteDialUpPPPDialInIdleTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 8 Description Defines the PPP idle time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Dial Up PPP Dial In Maximum Connection Time out Name remoteDialUpPPPDialInMaxConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 9 Description Defines the PPP connect time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write 502 Remote Access Group Remote Dial Up Dial Out Modem Connect Time out Name remoteDialUpDialOutModemConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 10 Description Defines the modem dial o
385. ing SIZE 0 64 Access Read only Field Replaceable Unit Group 549 FRU Revision Name Name fruRevisionName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 9 Description Defines the revision of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 10 Description Defines the manufacturing date of the FRU Syntax DellD ateN ame Access Read only FRU Asset Tag Name Name fruAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 11 Description Defines the asset tag of the FRU Syntax DisplayString SIZE 0 64 Access Read only 550 Field Replaceable Unit Group Field Replaceable Unit Group Variable Values This section includes definitions for server administrator specific variable values Table 23 1 FRU Information State Variable Name De 1 1FRUInformationState Data Type Integer Possible Data Values Meaning of Data Value ok 1 FRU information is okay not Supported 2 FRU information is not supported notAvailable 3 FRU information is not available checksumInvalid 4 FRU information checksum is invalid corrupted 5 FRU information is corrupted Field Replaceable Unit Group 551 552 Field Replaceable Unit Group Storage Management Group The Storage M anagement Group is composed of the following e Storage Management Group information about the software pro
386. ings NOTE The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding Data Type Integer Possible Data Values Meaning of Data Value automat icRebootEnabled 1 Automatic reboot is enabled for this host automaticPowerCycleEnabled 2 Automatic power cycleable is enabled for this host automat icNotificationEnabled 4 Automatic notification is enabled for this host automat icPowerOffEnabled 8 Automatic power off is enabled for this host 116 Chassis Information Group Table 6 15 Watchdog Timer Capabilities Variable Name De1 1Wat chDogTimerCapabilities Data Type Integer Possible Data Values Meaning of Data Value typelCapable 1 Watchdog timer can time in intervals from 20 480 seconds type2Capable 2 Watchdog timer can time in 30 60 120 and 480 second intervals type3Capable 4 Watchdog timer can time in 60 second intervals Table 6 16 Power Button Control Capabilities Variable Name Del 1PowerButtonControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no capabilities unknownCapabilities 1 The power button capabilities are unknown enableCapable 2 The power button can be enabled online or disabled offline Table 6 17 Power Button Control Settings Variable Name De 1 1PowerButtonControlSettings
387. ings Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 4 Description Defines the state of the PCI device Syntax DellStateSettings Access Read write PCI Device Status Name pCIDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 5 Description Defines the status of the PCI device Syntax DellStatus Access Read only 298 Device Group PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 6 Description Defines the index number of the system slot that this PC I deviceisin Syntax DellO bjectRange Access Read only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 7 Description Defines the bus width of the PCI device in this chassis Syntax DellUnsigned32BitRange Access Read only PCI Device Manufacturer Name Name Object ID Description Syntax Access pCIDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 80 1 8 Defines the name of the PCI device manufacturer DellString Read only PCI Device Description Name Name Object ID Description Syntax Access pCIDeviceDescriptionName 1 3 6 1 4 1 674 10892 1 1100 80 1 9 Defines the descriptive name of the PCI device DellString Read only Device Group 299 PCI Device Speed Name pCIDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 10 Description Defines the bus speed in M Hz of the PCI device in this chassis A zero 0 indicates
388. ip Group COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 28 Description Defines the name of the company that insures this system Syntax DellC ostofO wnershipString Access Read write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 29 Description Defines the name of the asset tag Syntax DellC ostofO wnershipString Access Read write COO Box System Name Name cooBoxSystemName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 30 Description Defines the name of the system Syntax DellC ostofO wnershipString Access Read write COO Box Central Processing Unit CPU Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 31 Description Defines the name of the CPU serial number for the system Syntax DellC ostofO wnershipString Access Read write Costof Ownership Group 445 COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 32 Description Defines the name of the operating system on this system Syntax DellC ostofO wnershipString Access Read write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelNam Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 33 Description Defines the name of the operating system patch level for this system Syntax DellC ostofO wnershipString Access Read write
389. iption Syntax Access Fan Name Name Object ID Description Syntax Access Fan Vendor Name Object ID Description Syntax Access fanNumber 1 3 6 1 4 1 674 10893 1 20 130 7 1 1 Identifies the instance number of the fan entry Integer Read only Fan Name 1 3 6 1 4 1 674 10893 1 20 130 7 1 2 Identifies the fan s name as represented in Storage M anagement DisplayString Read only fanVendor 1 3 6 1 4 1 674 10893 1 20 130 7 1 3 Identifies the fan s re seller s name DisplayString Read only Storage Management Group 619 Fan State Name Object ID Description Syntax Access Fan Severity Name Object ID Description Syntax Access Fan Probe Unit Name Object ID Description Syntax Access fanState 1 3 6 1 4 1 674 10893 1 20 130 7 1 4 Identifies the current state of the fan Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 D egraded 21 Missing Integer Read only fanSeverity 1 3 6 1 4 1 674 10893 1 20 130 7 1 5 This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Integer Read only fanProbeUnit 1 3 6 1 4 1 674 10893 1 20 130 7 1 6 This entry is obsolete for Storage Services DisplayString Read only 620 Storage Management Group Fan Probe Minimum Warning Name Object ID Description Syntax Access fanProbeMinimumWarning 1 3 6 1 4 1 674 10893 1 20 130 7 1
390. is performed for the admin user emailTest 8 An e mail test is performed for the admin user Table 20 16 Remote User Admin Alpha Protocol Type Variable Name De 1 1RemoteUserAdminAlphaProtocolType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user admin alpha protocol type is not one of the following unknown 2 The remote user admin alpha protocol type is unknown alpha7EO0 3 The remote user admin alpha protocol type is 7E0 alpha8N1 4 The remote user admin alpha protocol type is 8N 1 518 Remote Access Group Table 20 17 Remote User Admin Alpha Baud Type Variable Name De 1 1Remot eUserAdminAlphaBaudType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user alphanumeric baud rate is not one of the following unknown 2 The remote user alphanumeric baud rate is unknown alphaBaud300 3 The remote user alphanumeric baud rate is 300 alphaBaud1200 4 The remote user alphanumeric baud rate is 1200 Table 20 18 Remote SNMP Trap State Capabilities Variable Name De 1 1RemoteSNMPTrapStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state capabilities unknownCapabilities 1 The SNMP trap destination state capabilities are unknown enableCapable 2 The SNMP tra
391. ist Name systemStateCoolingUnitStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 45 Description Lists the status of each cooling unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit The first byte returned represents the status of the first cooling unit and so on The bytes have the same definition type as D ellStatus Syntax Octet String Size 1 128 Access Read only System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 46 Description Defines the combined status of all AC power switches of this chassis Syntax DellStatus Access Read only 66 System State Group System State AC Power Switch Status List Name Object ID Description Syntax Access systemStateACPowerSwitchStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 47 Lists the status of each AC power switch of this chassis T he results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch The first byte returned represents the status of the first AC power switch and so on The bytes have the same definition type as D ellStatus Octet String Size 1 128 Read only System State Redundant Memory Unit Status Combined Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusCombined 1 3 6 1
392. ity to support the hash digest mechanism K NOTE The default SNM P agent configuration usually includes a SNM P community name such as public For security reasons change the SNMP community names from their default values For information about changing SNM P community names see the Dell OpenM anage Server Administrator User s Guide available on the Dell Support website at support dell com manuals For additional guidelines see the Securing an SNMP Environment article dated M ay 2003 in the Dell Power Solutions magazine This magazine is also available at dell com powersolutions K NOTE Server Administrator provides support to enable or disable SNMP Set operations For more information on enabling or disabling SNM P Set operations in Server Administrator see the Dell OpenM anage Server Administrator User s Guide or the Dell OpenM anage Server Administrator Command Line Interface User s Guide on the Dell Support website at support dell com manuals 36 Introduction Management Actions Management actions can be performed using the SNM P Set command These actions can consist of configuring a phone number for the system s owner rebooting a system or changing the asset tag of the system See the previous section SNM P Security on page 36 for limitations on Set operations SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations hard drive failures and so on M anagement ap
393. l Disk Current Stripe Size in Bytes Name Object ID Description Syntax Access virtualDiskCurStripeSizelInBytes 1 3 6 1 4 1 674 10893 1 20 140 1 1 15 Identifies the portion of the stripe size in bytes that is smaller than a megabyte This size plus the virtualD iskC urStripeSizel nM B is the total stripe size on the virtual disk Integer Read only Virtual Disk Channel Name Object ID Description Syntax Access virtualDiskChannel 1 3 6 1 4 1 674 10893 1 20 140 1 1 16 This entry is obsolete T his property is not supported by virtual disks managed under Storage M anagement Integer Read only Virtual Disk Target ID Name Object ID Description Syntax Access virtualDiskTargetID 1 3 6 1 4 1 674 10893 1 20 140 1 1 17 Unique ID for the virtual disk Integer Read only Virtual Disk LUN ID Name Object ID Description Syntax Access virtualDiskLunID 1 3 6 1 4 1 674 10893 1 20 140 1 1 18 This entry is obsolete T his property is not supported by virtual disks managed under Storage M anagement Integer Read only Storage Management Group 663 Virtual Disk Roll Up Status Name virtualDiskRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 19 Description Severity of the virtual disk state T his isthe combined status of the virtual disk and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus
394. l Table 583 Enclosure Table a n naana 588 Array Disk Table 0 599 Array Disk Enclosure Connection Table 613 Array Disk Channel Connection Table 615 Fan TaD Oy ee Sty a a a Soke te EA 618 Fan Connection Table 624 Power Supply Table 626 Power Supply Connection Table 631 Temperature Probe Table 633 Temperature Probe Connection Table 638 Enclosure Management M odule Table 640 Enclosure Management Module Connection Table 645 BatteryTable 648 Battery Connection Table 654 Contents Logical Devices Group 656 Virtual Disk Table 2 ee ee 656 Array Disk Logical Connection Table 666 Storage Management EventGroup 669 25 Change Management Group 673 InventoryGroup 673 Device Group 0 4 674 Device Group Table nananana aaa 674 ApplicationGroup 676 Application Group Table 677 Operating SystemGroup 679 Inventory Collector Product Information 680 26 Dell Remote Access Controller Out of Band Group 683 27 Tra Product Information 683 Chassis Status 0000 687 DRsCMCChangeTime 696 ChassisPower 00004 697 CMC Power Information 698 CMC PSU Information
395. lNIF wakeonL anC ontrolSettingsU nique See Table 17 4 Read only BIOS Setup Control NIF Wakeup on LAN Control Status Name Object ID Description Syntax Access bSUCnIFwakeonLanControlStatus 1 3 6 1 4 1 674 10892 1 1400 10 1 20 Defines the status of the NIF Wakeup on LAN DellStatus Read only BIOS Setup Control NIF Wakeup on LAN Control Name Name Object ID Description Syntax Access bSUCnIFwakeonLanControlName 1 3 6 1 4 1 674 10892 1 1400 10 1 21 Defines the setup BIOS name of the NIF Wakeup on LAN DellString Read only BIOS Setup Control Boot Sequence Control Capabilities Unique Name Object ID Description Syntax Access bSUCbootSequenceControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 10 1 22 Defines the capabilities of the boot sequence DellBootSequenceC ontrolC apabilitiesU nique See Table 17 5 Read only BIOS Setup Control Boot Sequence Control Settings Unique Name Object ID DellBootSequenceControlSettingsUnique 1 3 6 1 4 1 674 10892 1 1400 10 1 23 395 BIOS Setup Control Group Name DellBootSequenceControlSettingsUnique Description Defines the state of the boot sequence Syntax D ellBootSequenceC ontrolSettingsU nique See Table 17 6 Access Read only BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 24 Description Defines the status of the boot sequence Syntax DellStatus Access Read only BIOS
396. lO bjectRange Read only Redundant Memory Unit Index Name Object ID Description Syntax Access redundantMemoryUnit Index 1 3 6 1 4 1 674 10892 1 1300 50 1 2 Defines the index one based of the redundant memory unit DellO bjectRange Read only Redundant Memory Unit State Capabilities Name Object ID Description Syntax Access redundantMemoryUnitStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 50 1 3 Defines the state capabilities of the redundant memory unit DellStateC apabilities Read only MemoryGroup 377 Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 4 Description Defines the state settings of the redundant memory unit Syntax DellStateSettings Access Read write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 5 Description Defines the redundancy status of the redundant memory unit Syntax DellStatusR edundancy Access Read only Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 6 Description Defines the name of the redundant memory unit Syntax DellString Access Read only Redundant Memory Unit Status Name redundantMemoryUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 7 Description Defines the status of the redundant memory unit Syntax DellStatus Access Read only 378 Memory G
397. le Possible Data Values Meaning of Data Value none 0 No mode capabilities modemBasic 1 BMC serial interface supports M odem Basic mode modemPPP 2 BMC serial interface supports M odem Point to Point Protocol PPP mode modemTerminal 4 BMC serial interface supports M odem Terminal mode directBasic 8 BMC serial interface supports Direct Basic mode directPPP 16 BMC serial interface supports Direct PPP mode directTerminal 32 BMC serial interface supports Direct Terminal mode Table 22 2 BMC Serial Connection Mode Settings Variable Name De 11 BMCSerialConnectionModeSettings Data Type Integer These values are bit masks therefore combination values are possible Possible Data Values Meaning of Data Value none 0 No modes enabled modemBasic 1 M odem Basic mode is enabled modemPPP 2 M odem PPP mode is enabled modemTerminal 4 M odem Terminal mode is enabled directBasic 8 Direct Basic mode is enabled directPPP 16 Direct PPP mode is enabled directTerminal 32 Direct Terminal mode is enabled 543 Baseboard Management Controller Group Table 22 3 BMC Serial Flow Control Type Variable Name De 1 1BMCSerialFlowControlType Data Type Integer Possible Data Values Meaning of Data Value none 0 No flow control used rtscts 1 RTS CTS hardware flow control used xonXoff 2 XON XOFF flow control used
398. le 8 8 Resource DMA Transfer Width Variable Name De 1 1 ResourceDMATransferWidth Data Type Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther 1 The DMA transfer width is not one of the following dmaTransferWidthIsunknown 2 TheDMA transfer width is unknown dmaTransferWidthIs8Bits 3 The DMA transfer width is 8 bits dmaTransferWidthIs1l6Bits 4 TheDMA transfer width is 16 bits dmaTransferWidthIs32Bits 5 TheDMA transfer width is 32 bits dmaTransferWidthIs64Bits 6 TheDMA transfer width is 64 bits dmaTransferWidthIs128Bits 7 TheDMA transfer width is 128 bits System Resource Group 149 150 l System Resource Group Power Group The Power Group provides information about power units a group of power supplies in a system chassis power supplies and voltage and amperage probes K NOTE Power M anagement features are only available for PowerEdge systems that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed Power Group Tables The following management information base M IB tables define objects for the Power Group e Power Unit Table on page 151 e Power Supply Table on page 154 e Voltage Probe Table on page 158 e Amperage Probe Table on page 163 e AC Power Switch Table on page 169 e AC Power Cord Table on page 171 Battery Table on page 174 e Power Usage Table on page
399. le Name Name Object ID Description Syntax Access enclosureManagementModuleName 1 3 6 1 4 1 674 10893 1 20 130 13 1 2 Identifies the enclosure management module s name as represented in Storage M anagement DisplayString Read only Enclosure Management Module Vendor Name Object ID Description Syntax Access enclosureManagementModuleVendor 1 3 6 1 4 1 674 10893 1 20 130 13 1 3 Identifies the enclosure management module s re seller s name DisplayString Read only Storage Management Group 641 Enclosure Management Module State Name enclosureManagementModuleState Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 4 Description Identifies the current state of the enclosure management module Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 5 Not Installed 6 D egraded 21 Missing Syntax Integer Access Read only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 5 Description This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 6 Description Identifies the part number of the enclosure memory module Syntax Display String Access Read only 642 Storage Management Group Enc
400. ler Encryption Capable Name controllerEncryptionCapable Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 57 Description Indicates encryption capability of the controller Value 1 Capable 99 Not Applicable Syntax Integer Access Read only Controller Encryption Key Present Name controllerEncryptionKeyPresent Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 58 Description Indicates presence of encryption key for the controller Value 1 Yes 0 No 99 Not Applicable Syntax Integer Access Read only 580 Storage Management Group Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 59 Description Indicates Persistent H ot Spare capability of the controller Value 1 Enabled 0 Disabled Syntax Integer Access Read only Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 60 Description Indicates controller capability to put unconfigured drives in power save mode Value 1 Enabled 0 Disabled Syntax Integer Access Read only Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 61 Description Indicates controller capability to put hot spare drives in power save mode Value 1 Enabled 0 Disabled Syntax Integer Access Read only Controller Spin Down Time Interval Name controllerSpinDownTim
401. llO bjectRange Access Read only Remote Dial Out State Capabilities Name remoteDialOutStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 4 Description Defines the state capabilities of this remote access dial out functionality Syntax DellRemoteD ialO utStateC apabilities See Table 20 27 Access Read only Remote Dial Out State Settings Name remoteDialOutStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 5 Description Defines the state settings of this remote access dial out functionality Syntax DellRemoteD ialO utStateSettings See Table 20 28 Access Read write 508 Remote Access Group Remote Dial Out Status Name Object ID Description Syntax Access remoteDialOutStatus 1 3 6 1 4 1 674 10892 1 1700 60 1 6 Defines the status of this remote access dial out functionality DellStatus Read only Remote Dial Out IP Address Name Object ID Description Syntax Access remoteDialOutIPAddress 1 3 6 1 4 1 674 10892 1 1700 60 1 7 Defines the IP address for this remote access dial out destination pAddress Read write Remote Dial Out Phone Number Name Name Object ID Description Syntax Access remoteDialOutPhoneNumberName 1 3 6 1 4 1 674 10892 1 1700 60 1 8 Defines the phone number for this remote access dial out destination DisplayString SIZE 0 95 Read write Remote Dial Out PPP Username Name Object ID Description Syntax Access remoteDialOutPP
402. llUnsigned32BitRange Access Read only Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 10 Description Defines the total number of memory sockets available for the physical memory array Syntax DellUnsigned32BitRange Access Read only 366 l M emory Group Physical Memory Array In Use Number Sockets Name Object ID Description Syntax Access physicalMemoryArrayInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 10 1 11 Defines the total number of memory sockets in use by the physical memory array DellU nsigned32BitRange Read only Physical Memory Array ECC Error Nonrecoverable Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorNonRecoverbeThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 12 Defines the value of the physical memory array Error Checking and Correction ECC error nonrecoverable threshold DellSigned32BitRange Read only Physical Memory Array ECC Error Critical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 13 Defines the value of the physical memory array ECC error critical threshold DellSigned32BitRange Read only Physical Memory Array ECC Error Noncritical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErro
403. lock Syntax DellString Access Read only BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 10 Description Defines if the processor serial number can be returned Syntax D ellStateC apabilities Access Read only BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 11 Description Defines the state of the processor serial number 392 BIOS Setup Control Group Name bSUCprocessorSerialNumberControlSettings Syntax DellStateSettings Access Read only BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 12 Description Defines the status of the processor serial number Syntax DellStatus Access Read only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 13 Description Defines the setup BIOS name of the processor serial number Syntax DellString Access Read write BIOS Setup Control Speaker Control Capabilities Unique Name bSUCspeakerControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 14 Description Defines the capabilities of the speaker control Syntax DellSpeakerC ontrolC apabilitiesU nique See Table 17 1 Access Read
404. losure Management Module Type Name enclosureManagementModuleType Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 7 Description _ dentifiesthetype of the enclosure management module Possible values 0 Unknown 1 EMM 2 Termination Card Syntax Integer Access Read only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 8 Description Identifies the firmware version of the enclosure memory module Syntax DisplayString Access Read only Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 9 Description Identifies the maximum bus speed of the enclosure management module Syntax DisplayString Access Read only Storage Management Group 643 Enclosure Management Module Roll Up Status Name enclosureManagementModuleRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 10 Description Severity of the enclosure management module state This is the combined status of the EM M and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 11 Description T he status of the enclosure management module itself without the propagation of any con
405. m factor is a row of chips deviceFormFactorIsRIMM 12 Device form factor isRIMM deviceFormFactorIsSODIMM 13 Device form factor isSODIMM deviceFormFactorIsSRIMM 14 Device form factor isSRIMM deviceFormFactorIsFBDIMM 15 Device form factor isFB DIMM Table 14 16 Memory Device Type Variable Name Del 1MemoryDevic Data Type Integer Typ Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypelIsUnknown 2 Device type is unknown deviceTypelIsDRAM 3 Device type is DRAM deviceTypeIsEDRAM 4 Device type isEDRAM DeviceGroup 339 Table 14 16 Memory Device Type continued Variable Name De 1 1MemoryDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value deviceTypeIsVRAM 5 Device type is VRAM deviceTypelIsSRAM 6 Device type is SRAM deviceTypeIsRAM 7 Device type is RAM deviceTypeIsROM 8 Device type isROM deviceTypelIsFLASH 9 Device type is FLASH deviceTypeIsEEPROM 10 Device type is EEPROM deviceTypeIsFEPROM 11 Device type is FEPROM deviceTypeIsEPROM 12 Device type is EPROM deviceTypeIsCDRAM 13 Device type is CDRAM deviceTypeIs3DRAM 14 Device type is 3DRAM deviceTypeIsSDRAM 15 Device type is SDRAM device
406. mber Name arrayDiskChannelConnectionChannelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 5 Description Identifies the instance number of the channel in the channelTable to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Controller Name Name arrayDiskChannelConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected Syntax DisplayString Access Read only Storage Management Group 617 Array Disk Channel Connection Controller Number Name Object ID Description Syntax Access Fan Table arrayDiskChannelConnectionControllerNumber 1 3 6 1 4 1 674 10893 1 20 130 6 1 7 Identifies the instance number in the controllerTable of the controller to which this array disk is connected Integer Read only This table describes available properties for each fan on the managed system The following object sets up the Fan Table Name Object ID Description Syntax Access Fan Entry Name Object ID Description Syntax Access Index fanTable 1 3 6 1 4 1 674 10893 1 20 130 7 Defines the fan table SEQUENCE OF FanEntry Not accessible fanEntry 1 3 6 1 4 1 674 10893 1 20 130 7 1 Defines the fan table entry FanEntry Not accessible fanN umber 618 Storage Management Group Fan Number Name Object ID Descr
407. me De 1 1ResourceMemoryFlags Data Type Integer Possible Data Values Meaning of Data Value memoryIsReadOnly 1 The resource memory is read only memoryIsWriteOnly 2 The resource memory is write only memoryIsPreFetchable 4 The resource memory is prefetchable memoryIsCombinedWritable 8 The resource memory is read write memoryIsF24 16 The resource memory is F24 System Resource Group 147 Table 8 5 Resource Interrupt Type Variable Name De11ResourcelInterruptType Data Type Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive 1 Theinterrupt type is level sensitive interrupt IsLatched 2 The interrupt type is latched Table 8 6 Resource Interrupt Trigger Variable Name De 1ResourcelInterruptTrigger Data Type Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow 1 Theinterrupt trigger is active on a low signal interrupt IsActiveWhenHigh 2 Theinterrupt trigger is active on a high signal Table 8 7 Resource DMA Bus Master Variable Name De 1 1ResourceDMABusMaster Data Type Integer Possible Data Values Meaning of Data Value dmaIsOther 1 The DMA bus master capability is not one of the following dmalIsUnknown 2 The DMA bus master capability is unknown dmaIsNotABusmaster 3 The DMA does not have bus master capability 148 l System Resource Group Tab
408. me Object ID Description Syntax Access controllerAlarmState 1 3 6 1 4 1 674 10893 1 20 130 1 1 40 Indicates state or setting for the controller s alarm Possible values 1 Enabled 2 Disabled 3 Not Applicable Integer Read only Controller Driver Version Name Object ID Description Syntax Access controllerDriverVersion 1 3 6 1 4 1 674 10893 1 20 130 1 1 41 Indicates currently installed driver version of the controller DisplayString Read only Controller PCI Slot Name Object ID Description controllerPCISlot 1 3 6 1 4 1 674 10893 1 20 130 1 1 42 Indicates the PCI slot number or embedded number for controllers on the motherboard Storage Management Group 575 Name controllerPCISlot Syntax DisplayString Access Read only Controller Cluster Mode Name controllerClusterMode Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 43 Description Identifies if the controller is in cluster mode Possible values 1 Enabled 2 Disabled 3 Active enabled and active 99 Not Applicable Syntax Integer Access Read only Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 44 Description The minimum firmware version for Storage Management to support the controller Syntax DisplayString Access Read only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 45 Description The minimum
409. me networkDeviceDHCPServerIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device Syntax pAddress Access Read only Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 15 Description Defines the current MAC address of the network device Syntax DellM AC Address Access Read only Network Device Permanent MAC Address Name networkDevicePermanentMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 16 Description Defines the permanent MAC address of the network device Syntax DellM AC Address Access Read only DeviceGroup 307 Network Device PCI Bus Number Name Object ID Description Syntax Access networkDevicePCIBusNumber 1 3 6 1 4 1 674 10892 1 1100 90 1 17 Defines the PCI bus number of the network device DellU nsigned8BitRange Read only Network Device PCI Device Number Name Object ID Description Syntax Access networkDevicePCIDeviceNumber 1 3 6 1 4 1 674 10892 1 1100 90 1 18 Defines the PCI device number of the network device DellU nsigned8BitRange Read only Network Device PCI Function Number Name Object ID Description Syntax Access networkDevicePCIFunctionNumber 1 3 6 1 4 1 674 10892 1 1100 90 1 19 Defines the PCI function number of the netw
410. me of the manufacturer of the product DisplayString Read only Product ID Version Name Object ID Description Syntax Access product IDVersion 1 3 6 1 4 1 674 10899 100 4 Describes the version of the product DisplayString Read only Change Management Group 681 682 Product ID Build Number Name product IDBuildNumber Object ID 1 3 6 1 4 1 674 10899 100 5 Description Describes the software build number of the product Syntax DisplayString Access Read only Change M anagement Group Dell Remote Access Controller Out of Band Group The Dell Remote Access C ontroller Out of Band M IB contains information for both Chassis Management C ontroller CMC and RAC Legacy Alerting This MIB consists of information for the following groups Product Information The following M IB tables define the Dell RAC Out of Band group DRsProductName Name DRsProductName Object ID 1 3 6 1 4 1 674 10892 2 1 1 1 Description Defines the product name of a chassis management controller Syntax DellString Access Read only DRsProductShortName Name DRsProductShortName Object ID 1 3 6 1 4 1 674 10892 2 1 1 2 Description Defines the short product name of a chassis management controller Syntax DellString Access Read only Dell Remote Access Controller Out of Band Group 691 DRsProductDescription Name DRsProductDescription Object ID 1 3 6 1 4 1 674 10892 2 1 1 3 Description Defines the product description of a chassis manag
411. ment ROOT CCITT 0 1SO 1 ORG 3 DOD 6 INTERNET 1 MGMT 2 MIB 1 EXPERIMENTAL 3 PRIVAT E 4 ENTERPRISES 1 DELL 674 SNM Pv2 6 Introduction 35 In the preceding example the OID prefix for the Dell enterprise would be 1 3 6 1 4 1 674 The numbers in boldface type show the categories and numbers that apply to Server Administrator All Server Administrator defined OID s consist of 1 3 6 1 4 1 674 followed by additional component values SNMP Security SNMP version 1 has a very limited security mechanism SNM P agents support the use of a community string which is configured at each SNM P agent and is passed as a part of all SNMP request messages T here is no verification that the requester is actually a member of the specified community As most system and network management data is not confidential this limited security is acceptable for Get types of requests On the other hand this security is not acceptable for Set types of operations where an SNM P request could power off a system reconfigure a redundant array of independent disks RAID card and so on Some vendors have chosen not to support SNM P Set operations for this reason Server Administrator is able to support SNMP Set operations because its SNM P agents implement a hash digest mechanism to prevent unauthorized SNM P Set operations One limitation of this practice is that only server administrator developed SN M P management applications have the capabil
412. mentModule 5 The baseboard type is a system management module processorModule 6 The baseboard type is a processor module ioModule 7 The baseboard type is an I O module memoryModule 8 The baseboard type is a memory module daughterBoard 9 The baseboard type is a daughter board motherboard 10 The baseboard type is a mother board processorMemoryModule 11 The baseboard type isa processor or memory module processorIOModule 12 The baseboard type is a processor or 1 0 module interconnectBoard 13 The baseboard type is an interconnect board Table 6 24 Baseboard Feature Flags Variable Name De 1 1BaseBoardFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value NOTE These values are bit fields so combination values are possible no features 0 This baseboard has no feature flags boardIsHostingBoard 1 This baseboard is a hosting board Chassis Information Group 121 Table 6 24 Baseboard Feature Flags Variable Name De 1 1BaseBoardFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value boardRequiresDaughterBoard This baseboard requires at least one 2 daughter board or auxiliary card boardIsRemovable 4 This baseboard is removable boardIsReplaceable 8 This baseboard is replaceable boardIsHotSwappable 16 This baseboard is hot swappable 122 Chassis Information Group Operating System Group The Operating System Group
413. meric pager phone number for this remote access user Syntax DisplayString SIZE 0 95 Access Read write Remote User Admin Pager Alpha Protocol Name remoteUserAdminPagerAlphaProtocol Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 19 Description Defines the protocol used by the alphanumeric pager provider for this remote access user Syntax DellRemoteU serAdminAlphaProtocolT ype See Table 20 16 Access Read write Remote User Admin Pager Alpha Baud Rate Name remot eUserAdminPagerAlphaBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 20 Description Defines the baud rate used by the alphanumeric pager provider for this remote access user Syntax DellRemoteU serAdminAlphaBaudType See Table 20 17 Access Read write 492 Remote Access Group Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Alpha Modem Connect Time out Name remot eUserAdminPagerAlphaModemConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 22 Description Defines the modem connection time out for the alphanumeric pager for this remote access user Syntax DellU nsigned32BitRange Access Read write Remote User Admin Pager Alpha Pager ID Name N
414. milyIsA e 234 DAthlonDualCor The processor family is AM D Athlon Dual Core deviceFamilyIsA 235 DSempronsI The processor family is AMD Sempron SI DeviceGroup 333 Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDPhenomII 236 The processor family is AMD Phenom I deviceFamilyIsAMDAthlonII 237 The processor family is AMD Athlon II deviceFamilyIsSixCoreAMDOptero n 238 The processor family is Six C ore AM D Opteron deviceFamilyIsAMDSempronM 239 The processor family is AMD Sempron M deviceFamilyIsi860 250 The processor family is i860 deviceFamilyIsi960 251 The processor family is i960 deviceFamilyIsAMDOpteron6200 61 The processor family family is AM D Opteron 6200 Series Processor deviceFamilyIsAMDOpteron4200 61 The processor family family is AM D Opteron 4200 Series Processor Table 14 7 Cache Device Type Variable Name De 1 1CacheDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 System cache type is not one of the following deviceTypeIsUnknown 2 System cache type is unknown deviceTypeIsInstruction 3 System cache type is instruction deviceTypelIsData 4 System cache type is d
415. mming Interface API a MIB allows systems management tools to retrieve data maintained by an agent T he server administrator M IB is divided into several major groups of managed objects Variable A variable is a component of a managed object A temperature probe for example has a variable to describe its capabilities its health or status and certain indexes that you can use to locate specific temperature probes One index for the probe would be the probe s chassis number Some systems may have multiple chassis one chassis for the central processing unit and another chassis for storage A chassis within a system can also have more than one temperature probe Variables for a temperature probe include its capabilities status chassis index and index One Based Index W hen an index is one based counting starts at 1 One based indexing counts the first instance as 1 the second index as 2 and so on 26 Introduction Zero Based Index W hen an index is zero based counting starts at 0 Z ero based indexing counts the first instance as 0 the second index as 1 and so on Fields M anaged object variables contain fields In this reference guide managed object variables have the following fields defined Name isthe exact string by which the variable is known in the MIB M IB variables are named according to the following conventions e Variable names start with a lowercase letter Spaces are not allowed between words
416. mode All other bits are product specific Syntax Integer Access Read only Agent Refresh Rate Name agentRefreshRat Object ID 1 3 6 1 4 1 674 10893 1 20 110 6 Description Identifies the rate given in seconds at which the cached data for SN MP is refreshed T he default value is 300 seconds or 5 minutes Syntax Integer Access Read only Agent Hostname Name agentHostname Object ID 1 3 6 1 4 1 674 10893 1 20 110 7 Description This entry is obsolete for Storage M anagement Syntax DisplayString Access Read only 558 Storage Management Group Agent IP Address Name agentIPAddress Object ID 1 3 6 1 4 1 674 10893 1 20 110 8 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Agent Software Status Name agent SoftwareStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 9 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Agent SNMP Version Name agentSnmpVersion Object ID 1 3 6 1 4 1 674 10893 1 20 110 10 Description This entry is obsolete Refer to 0001 softwareVersion Syntax DisplayString Access Read only Agent MIB Version Name Object ID Description Syntax Access agentMibVersion 1 3 6 1 4 1 674 10893 1 20 110 11 Identifies the version of the Storage M anagement M IB DisplayString Read only Storage Management Group 559 Agent Management Software URL Name Name agentManagement SoftwareURLName Obj
417. mory module connection table entry Syntax EnclosureM anagementM oduleC onnectionE ntry Access Not accessible Index enclosureM anagementM oduleC onnectionN umber Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 1 Description Identifies the instance number of the enclosure memory module connection entry Syntax Integer Access Read only Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnect ionEMMName Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 2 Description Identifies the name of the enclosure memory module in this connection as represented in Storage M anagement Syntax DisplayString Access Read only 646 Storage Management Group Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnect ionEMMNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 3 Description Identifies the instance number in the enclosureM anagementM oduleTable of the enclosure memory module in this connection Syntax Integer Access Read only Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 4 Description Identifies the name of the enclosure as represented in Storage M anagement to which this enclosure memory module belongs Syntax DisplayString Access Read only Enclosure Mana
418. moryDeviceFormFactor Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 12 Description Defines the form factor of the memory device Syntax DellM emoryD eviceFormF actor See Table 14 15 Access Read only Memory Device Set Name memoryDeviceSet Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 13 Description Defines if the memory device is a part of a set A zero 0 indicates that this device is not part of a set Syntax DellUnsigned32BitRange Access Read only Memory Device Size Name memoryDeviceSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 14 Description Defines the size in KB of the memory device Syntax DellUnsigned32BitRange Access Read only Memory Device Speed Name memoryDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 15 Description Defines the speed in nanoseconds of the memory device A zero 0 indicates that the speed is unknown Syntax DellU nsigned32BitRange Access Read only DeviceGroup 287 Memory Device Total Bus Width Name Object ID Description Syntax Access memoryDeviceTotalBusWidth 1 3 6 1 4 1 674 10892 1 1100 50 1 16 Defines the total number of bits including ECC used by the memory device DellU nsigned32BitRange Read only Memory Device Total Data Bus Width Name Object ID Description Syntax Access memoryDeviceTotalDataBusWidth 1 3 6 1 4 1 674 10892 1 1100 50 1 17 Defines the total number of data bits used by the memory device DellU nsigned32BitRa
419. mum Size Name cacheDeviceMaximumSize Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 12 Description Defines the maximum size of the cache device in kilobytes KB A zero 0 indicates that the size is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Current Size Name cacheDeviceCurrentSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 13 Description Defines the current size of the cache device in KB A zero 0 indicates that the size is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Speed Name cacheDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 14 Description Defines the speed of the cache device in nanoseconds A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Write Policy Name cacheDeviceWritePolicy Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 15 Description Defines the write policy of the cache device Syntax DellC acheD eviceW ritePolicy See Table 14 9 Access Read only DeviceGroup 281 Cache Device Is Socketed Object ID Description Syntax Access cacheDevicelsSocketed 1 3 6 1 4 1 674 10892 1 1100 40 1 16 Defines if the cache device is socketed DellBoolean Read only Cache Device Error Checking and Correction ECC Type Name Object ID Description Syntax Access cacheDeviceECCTyp 1 3 6 1 4 1 674 10892 1 1100 40 1 17 Defines the type of error correction in use by the cache dev
420. n Health Media Integrated Dual SD ModuleWarning 2210 Integrated Dual SD System IDSDM M inor M odule warning Health M edia Integrated Dual SD ModuleFailure 2297 Integrated Dual SD System IDSDM Critical M odule failure Health M edia Table 29 19 Integrated Dual SD Module Absent Trap TrapID Description Category SubCategory Severity Integrated Dual SD ModuleAbsent 2481 Integrated Dual SD System IDSDM Critical M odule is absent Health Absent Table 29 20 Integrated Dual SD Module Redundancy Traps TrapID Description Category SubCategory Severity Integrated Dual SD Module Redundancy Information 2491 Integrated Dual SD System IDSDM Informational M odule redundancy Health Redundancy information Integrated Dual SD Module Redundancy Degraded 2490 Integrated Dual SD System IDSDM M inor M odule redundancyis Health Redundancy degraded Integrated Dual SD Module Redundancy Lost 2489 Integrated Dual SD System IDSDM Critical Module redundancyis Health Redundancy lost 758 iDRAC7 MIB Table 29 21 Security Event Traps TrapID Description Category SubCategory Severity Security Information 2387 Security information System Security Informational Health Event Security Failure 2385 Security failure or critical System Security Critical event Health Event Table 29 22 System Event Log Traps TrapID Description Category SubCategory Severity System Event Log Information 2379 System Eve
421. n Defines the index of the intrusion objects in this subgroup Syntax DellObjectRange Access Read only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 3 Description Defines the capabilities of the intrusion object Syntax D ellStateC apabilities Access Read only Intrusion State Settings Name intrusionStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 4 Description Defines the settings of the intrusion object Syntax DellStateSettings Access Read write Intrusion Status Name intrusionStatus Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 5 Description Defines the status of the intrusion object Syntax DellStatus Access Read only 102 Chassis Information Group Intrusion Reading Name intrusionReading Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 6 Description Defines the reading of the intrusion object Syntax DelllntrusionReading Access Read only Intrusion Type Name intrusionType Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 7 Description Defines the type of the intrusion object Syntax DelllntrusionType Access Read only Intrusion Location Name Name intrusionLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 8 Description Defines the location name of the intrusion object in this subgroup Syntax DellString Access Read only Baseboard Table This table lists objects that define the baseboard of a system Name baseBoardTable Object ID 1 3 6 1 4
422. n type the application version and the application description 676 l Change M anagement Group Application Group Table The following object sets up the Application Group Table Name Object ID Description Syntax Access Application Entry Name Object ID Description Syntax Access applicationTable 1 3 6 1 4 1 674 10899 1 6 Defines a table of application information for the system SEQUENCE OF ApplicationEntry Not accessible applicationEntry 1 3 6 1 4 1 674 10899 1 6 1 Defines an application entry ApplicationE ntry Read only Application Index Name Object ID Description Syntax Access applicationIndex 1 3 6 1 4 1 674 10899 1 6 1 1 Defines the unique index for this application Unsigned16BitR ange Read only Application Device Index Name Object ID Description Syntax Access applicationDeviceIndex 1 3 6 1 4 1 674 10899 1 6 1 2 Defines a cross index to the device table for the application Unsigned 16BitR ange Read only Change Management Group 677 Application Component Type Name applicationComponentType Object ID 1 3 6 1 4 1 674 10899 1 6 1 3 Description Identifies the type of application reported Syntax DisplayString Access Read only Application Version Name applicationVersion Object ID 1 3 6 1 4 1 674 10899 1 6 1 4 Description Identifies the version of the application Syntax DisplayString Access Read only Application Display String Name applicationDisplay
423. nagement type is Minimum Power Table 9 21 Fan Power Performance Management Type Variable Name De 1 1F anPowerPerformanceManagementTyp Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 Fan power and performance management type is Maximum Performance minPower 2 Fan power and performance management type is Minimum Power Power Group 197 198 Power Group Thermal Group The Thermal Group provides information about cooling units cooling devices and temperature probes C ooling units are sets of fans or other cooling devices in a system chassis Thermal Group variables include threshold values and types of cooling devices and temperature probes Thermal Group Tables The following management information base M IB tables define the objects in the Thermal Group e Cooling Unit Table on page 199 e Cooling Unit Status on page 201 e Temperature Probe Table on page 207 Cooling Unit Table Name coolingUnitTable Object ID 1 3 6 1 4 1 674 10892 1 700 10 Description Defines the Cooling Unit Table Syntax TableE ntry Access Not accessible Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 Description Defines the Cooling Unit Table entry Syntax TableE ntry Access Not accessible Index coolingU nitchassisl ndex coolingU nitl ndex Thermal G
424. nagement Group Enclosure Type Name enclosureType Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 16 Description Indicates the type of the enclosure Possible values Internal Dell PowerVault 200S PowerVault 201S Dell PowerVault 210S PowerVault 2115S Dell PowerVault 220S PowerVault 221S Dell PowerVault 660F Dell PowerVault 224F Dell PowerVault 660F PowerVault 224F Dell MD 1000 Dell M D 1120 Syntax DisplayString Oe St O OT S ND ake Ko Access Read only Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 17 Description T his entry is obsolete for Storage Management Syntax DisplayString Access Read only Storage Management Group 593 Enclosure Configuration Name enclosureConfig Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 18 Description Identifies the current configuration of the enclosure s backplane Possible values 1 Joined 2 Split Bus 3 Clustered 4 Unified Syntax Integer Access Read only Enclosure Channel Number Name enclosureChannelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 19 Description Identifies the channel number or bus to which the enclosure is connected Syntax Integer Access Read only Enclosure Alarm Name enclosureAlarm Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 20 Description Identifies the current status of the enclosure s alarm PowerVault 220S and PowerVault 221S only Possible values 1 Di
425. name to execute Syntax DisplayString SIZE 0 256 Access Read write LRA Action Table Settings Unique Name LRAActionTableSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 4 Description Defines the LRA settings Syntax DellLocalResponseAgentSettingsU nique See Table 18 3 Access Read write Local Response Agent Variable Values This section includes definitions for server administrator specific variable values used in this section Table 18 1 LRA Capabilities Definitions Variable Name De 1 1 LocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value speakerControlCapable 1 The LRA can issue a speaker beep consoleAlertCapable 2 The LRA can alert the console broadcastMessageCapable 4 TheLRA can broadcast a message osShutDownCapable 8 The LRA can shut down the operating system 434 Local Response Agent Group Table 18 1 LRA Capabilities Definitions continued Variable Name De 1 1 LocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value rebootCapable 16 The LRA can reboot the system powerCycleCapable 32 The LRA is capable of a system power cycle powerOFFCapable 64 The LRA can shut the system power off executeApplicationCapable 256 TheLRA can execute a user mode application lraFullyCapable 383 The LRA has all of the preceding
426. nce Table on page 460 e COO Repair Table on page 462 e COO Support Information Table on page 464 e COO Trouble Ticket Table on page 466 Cost of Ownership Table The following M IB object sets up the Cost of Ownership Table Name cooTable Object ID 1 3 6 1 4 1 674 10892 1 1600 10 Description Defines the C ost of Ownership Table Syntax SEQUENCE OF CooTableEntry Access Not accessible CostofOwnership Group 437 Cost of Ownership Table Entry Name cooTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 Description Defines the C ost of Ownership Table entry Syntax CooTableE ntry Access Not accessible Index coochassisl ndex COO Chassis Index Name coochassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 1 Description Defines the index one based of this chassis Syntax CooTableEntry Access Read only COO State Name cooState Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 2 Description Defines the acquisition state of the system Syntax DellStateSettings Access Read only COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 3 Description Defines the purchase cost of the system Syntax DellUnsigned32BitRange Access Read write 438 Cost of Ownership Group COO Acquisition Waybill Number Name Object ID Description Syntax Access cooAquisitionWayBillNumber 1 3 6 1 4 1 674 10892 1 1600 10 1 4 Defines the waybill number of the system DellU nsigne
427. ndicates the maximum speed at which the drive is capable of negotiating in MPS megabytes per second Integer Read only Storage Management Group 609 Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 31 Description Indicates whether the disk has received a predictive failure Possible values 1 No disk has not received a predictive failure alert 2 Yes disk has received a predictive failure alert Syntax Integer Access Read only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 32 Description _ _ ndicates the day of the week 1 Sunday through 7 Saturday on which this disk was manufactured Syntax DisplayString Access Read only Array Disk Manufacture Week Name arrayDiskManufactureWeek Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 33 Description Indicates the week 1 through 53 in which this disk was manufactured Syntax DisplayString Access Read only 610 Storage Management Group Array Disk Manufacture Year Name Object ID Description Syntax Access arrayDiskManufactureYear 1 3 6 1 4 1 674 10893 1 20 130 4 1 34 Indicates the four digit year in which this disk was manufactured DisplayString Read only Array Disk Media Type Name Object ID Description Syntax Access arrayDiskMediaType 1 3 6 1 4 1 674 10893 1 20 130 4 1 35 Indicates the media type of the array disk
428. nfiguration Table SEQUENCE OF RemoteUserD iallnC fgTableE ntry Not accessible Remote User Dial In Configuration Table Entry Name Object ID Description Syntax Access Index remoteUserDialiInCfgTableEntry 1 3 6 1 4 1 674 10892 1 1700 50 1 Defines the Remote Access U ser Dial In Configuration Table entry RemoteU serD iallnC fgTableE ntry Not accessible remoteU serD iall nC fgC hassisI ndex remoteU serD iallnC fgAdapterl ndex remoteU serD iall nC fgU serl ndex 504 l Remote Access Group Remote User Dial In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellO bjectRange Access Read only Remote User Dial In Configuration Adapter Index Name remot eUserDialInCfgAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial in user Syntax DellO bjectRange Access Read only Remote User Dial In Configuration User Index Name remoteUserDialInCfgUserIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 3 Description Defines the index one based of this remote access dial in user Syntax DellO bjectRange Access Read only Remote User Dial In Configuration State Capabilities Name remoteUserDialInCfgStateCapabilities Object ID 1 3 6 1
429. ng a preset number is enabled for the dial in user dialInCallbackUserSpecified Enabled 16 Callback using a user specified number is enabled for the dial in user Remote Access Group 523 Table 20 27 Remote Dial Out State Capabilities Variable Name De 1 1RemoteDialOutStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial out destination has no state capabilities unknownCapabilities 1 The dial out destination state capabilities are unknown enableCapable 2 The dial out destination can be disabled or enabled notReadyCapable 4 The dial out destination can be in the not ready state dial OutPPPAuthAnyCapable 8 The dial out destination can support any authentication type including clear text for PPP dial Out PPPAuthEncryptedCapable 16 The dial out destination can support encrypted passwords authentication type for PPP dial Out PPPAuthMschapCapable 32 The dial out destination can support MSC HAP authentication type for PPP 524 Remote Access Group Table 20 28 Remote Dial Out State Settings Variable Name De 1 1RemoteDialOutStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial out destination has no state settings unknown 1 The dial out destination state settings are unknown enabled 2 The
430. ngDeviceControlSettings Syntax DellStateSettings Access Read write BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 4 Description Defines the status of the pointing device Syntax DellStatus Access Read only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 5 Description Defines the setup BIOS name of the pointing device Syntax DellString Access Read only BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 6 Description Defines the capabilities of the numeric lock Syntax DellStateC apabilities Access Read only BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 7 Description Defines the state of the numeric lock 391 BIOS Setup Control Group Name bSUCnumLockControlSettings Syntax DellStateSettings Access Read only BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 8 Description Defines the status of the numeric lock Syntax DellStatus Access Read only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 9 Description Defines the setup BIOS name of the numeric
431. nge Read only Memory Device Correctable Memory Event Count NOTE M emory Device Failure M odes on page 289 has now replaced this attribute M emory Device Correctable M emory Event Count should no longer be used If you use the M emory Device Correctable M emory Event Count attribute the value returned is always zero and using the attribute has no effect Name Object ID Description Syntax Access memoryDeviceSingleBitErrorCount 1 3 6 1 4 1 674 10892 1 1100 50 1 18 Defines the total number of C orrectable M emory Events detected by the memory device DellSigned32BitRange Read only 288 Device Group Memory Device Uncorrectable Memory Event Count K NOTE M emory Device Failure M odes on page 289 has now replaced this attribute M emory Device Uncorrectable M emory Event Count should no longer be used If you use the M emory Device Uncorrectable M emory Event Count attribute the value returned is always zero and using the attribute has no effect Name memoryDeviceMultiBitErrorCount Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 19 Description Defines the total number of U ncorrectable M emory Events detected by the memory device Syntax DellSigned32BitRange Access Read only Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 20 Description Defines the failure modes of the memory device when the memoryD eviceStatus attribute is not OK It is
432. nknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Storage Management Group 629 Power Supply Component Status Name powerSupplyComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 9 Description Severity of the power supply state T his is the combined status of the power supply and its components Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Power Supply NexusID Name powerSupplyNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 10 Description Durable unique ID for this power supply Syntax DisplayString Access Read only Power Supply Revision Name powerSupplyRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 11 Description Indicates the revision number of the power supply in the enclosure Syntax DisplayString Access Read only 630 Storage Management Group Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Power Supply C onnection Table Name Object ID Description Syntax Access powerSupplyConnectionTable 1 3 6 1 4 1 674 10893 1 20 130 10 Defines the power supply connection table SEQUENCE OF PowerSupplyC onnectionE ntry Not accessible P
433. nly PCI Device Configuration Space State Capabilities Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 82 1 3 Defines the capabilities of the PCI device configuration DellStateC apabilities Read only PCI Device Configuration Space State Settings Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStateSettings 1 3 6 1 4 1 674 10892 1 1100 82 1 4 Defines the state of the PC device configuration DellStateSettings Read write Device Group 30 PCI Device Configuration Space Status Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStatus 1 3 6 1 4 1 674 10892 1 1100 82 1 5 Defines the status of the PCI device configuration DellStatus Read only PCI Device Index Reference Name Object ID Description Syntax Access pCIDeviceIndexReferenc 1 3 6 1 4 1 674 10892 1 1100 82 1 6 Defines the index number of PCI device that this configuration applies to DellO bjectRange Read only PCI Device Configuration Space Bus Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceBusNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 7 Defines the bus number of the PC device configuration in this chassis DellU nsigned32BitRange Read only PCI Device Configuration Space Device Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceDevic
434. nt processorThrottled 1024 The processor is throttled Table 14 4 Processor Device Type Variable Name De 11ProcessorDevic Data Type Integer Typ Possible Data Values Meaning of Data Value deviceTypelIsOther 1 The processor device type is not one of the following values deviceTypelIsUnknown 2 The processor device type is unknown deviceTypelIsCPU 3 The processor device type is a central processing unit deviceTypeIsMathProcessor 4 The processor device type is a math processor deviceTypelIsDSP 5 The processor device type is a digital signal processor deviceTypeIsAVideoProcessor 6 The processor device is a video processor 322 Device Group Table 14 5 Processor Upgrade Information Variable Name De 1 1ProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processor UpgradelIsOther 1 The upgrade device type is not one of the following processor UpgradelIsUnknown 2 Upgrade device type is unknown processor UpgradeIsByDaughterBoard 3 Upgrade device is ona daughter board processor UpgradeIsByZIFSocket 4 Upgrade device is in a zero insertion force ZIF socket processor UpgradeIsByReplacement 5 Upgrade device is a replacement processor UpgradeIsNone 6 There is no upgrade device processor Up
435. nt Log System Sys Event Informational information Health Log System Event Log Warning 2378 System Event Log System Sys Event M inor warning Health Log System Event Log Failure 2377 System Event Log failure System Sys Event Critical or critical event Health Log Table 29 23 Temperature Probe Traps TrapID Description Category SubCategory Severity Temperature Probe Normal 2163 Temperature sensor System Temperature Informational value is within range Health Temperature Probe Warning 2162 Temperature sensor has System Temperature Minor detected a warning value H ealth Temperature Probe Failure 2161 Temperature sensor has System Temperature Critical detected a failure value Health iDRAC7MIB 759 760 Table 29 24 vFlash Media Device Traps TrapID Description Category SubCategory Severity vFlash Media Device Information 2507 vFlash M edia device System vF lash Event Informational information Health vFlash Media Device Warning 2506 vFlash M edia device System vF lash Event Minor warning Health vFlash Media Device Failure 2505 vFlash M edia device System vF lash Event Critical failure Health Table 29 25 vFlash Media Device Absent Trap TrapID Description Category SubCategory Severity vFlash Media Device Absent 2515 vFlash Mediadeviceis System vF lash Informational absent Health Absent Table 29 26 Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage Probe Normal 2171 Voltage
436. o send SNM P event notifications called traps in SNM Pv1 The SNMP master agent is also responsible for sending SNM P event notification protocol messages to SNM P management applications On supported operating systems the SNM P master agent is provided with the operating system For example on supported M icrosoft Windows operating systems the W indows SNMP service is the SNM P master agent For information on the versions of the SNM P protocol supported by the SNMP master agent see the operating system documentation Introduction 25 SNMP Extension Agent The SNMP extension agent is responsible for registering the M IB objects that it supports with the SNM P master agent and then processing requests from the SNMP master agent for those M IB objects The SNMP extension agent also initiates event notifications to the SNM P master agent The SNM P extension agent does not receive or send standard SNM P protocol messages The SNMP extension agent communicates with the SNM P master agent using an extension protocol defined by the SNM P master agent T he Server Administrator SNMP subagent is an SNMP extension agent Managed Object A managed object is any item in a computer system that can be singled out for discovery monitoring or user intervention and correction K NOTE Not all managed objects described in this guide are supported by all systems A MIB acts as a structured road map for managed objects As an Application Progra
437. o that enclosure instance in the enclosure Table The following object sets up the Fan Connection Table Name Object ID Description Syntax Access fanConnectionTable fanC onnectionTable Defines the fan connection table SEQUENCE OF FanConnectionEntry Not accessible Fan Connection Entry Name Object ID Description fanConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 8 1 Defines the fan connection table entry Storage Management Group Name fanConnectionEntry Syntax FanC onnectionEntry Access Not accessible Index fanC onnectionN umber Fan Connection Number Name fanConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 1 Description Identifies the instance number of the fan connection entry Syntax Integer Access Read only Fan Connection Fan Name Name fanConnectionFanName Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 2 Description Identifies the name of the fan in this connection as represented in Storage M anagement Syntax DisplayString Access Read only Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 3 Description Identifies the instance number of the fan in the fanTable in the connection Syntax Integer Access Read only Storage Management Group 625 Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 4 Description Identifies the name of the enclosure as repre
438. of the pointing port Syntax D ellG enericPortC onnectorType Access Read only Keyboard Port Table Name keyboardPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 20 Description Defines the Keyboard Port Table Syntax IntegerK eyboardPortT ableE ntry Access Not accessible Keyboard Port Table Entry Name Object ID Description Syntax Access Index keyboardPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 20 1 Defines the Keyboard Port Table entry KeyboardPortTableE ntry Not accessible keyboardPortchassisIndex keyboardPortl ndex 230 Port Group Keyboard Port Chassis Index Name Object ID Description Syntax Access keyboardPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 20 1 1 Defines the index one based of this chassis DellO bjectRange Read only Keyboard Port Index Name Object ID Description Syntax Access keyboardPort Index 1 3 6 1 4 1 674 10892 1 1000 20 1 2 Defines the index of the keyboard ports in this chassis DellO bjectRange Read only Keyboard Port State Capabilities Name Object ID Description Syntax Access keyboardPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 20 1 3 Defines the capabilities of the keyboard port DellStateC apabilities Read only Keyboard Port State Settings Name Object ID Description Syntax Access keyboardPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 20 1 4 Defines the state and settings of the keyboard port DellStateSettings Re
439. of the variables defined in the M IBs the following fields are specified e Variable name e OID orunique identifying number e Description Datatype of the variable for example integer string octet string Whether the variable is accessible not accessible read only or read write Index or indexes if applicable Introduction 33 For each M IB group that has unique variable definitions tables are included in the last section of the section to explain the meaning of the terms Standards for writing M IBs are defined by the Internet Engineering Task Force IETF Structure of Management Information SM I is a standard that specifies the rules for defining the structure and type of managed objects and events in a M IB SM Iv1 is specified in Request For Comments RFC 1155 The Server Administrator M IB conforms to the SM Iv1 standard SNMP is asystems management standard originally designed for network management SN M P manages much more than networks Information Technology IT professionals use SNM P for monitoring and managing computer systems and the various components and peripherals supported by their systems SNMP standards are defined by the Internet Engineering Task Force IETF SNMP version 1 was published in August 1988 and is the most commonly supported version of SNM P SNM P version 2 was first published in M ay 1993 but has not gained widespread market acceptance SNM P version 3 was recently completed and has
440. on Syntax Access cooRepairCounter 1 3 6 1 4 1 674 10892 1 1600 90 1 4 Defines the number of repairs that this system has undergone DellC ostofO wnershipString Read write COO Repair Vendor Name Name Object ID Description Syntax Access cooRepairVendorName 1 3 6 1 4 1 674 10892 1 1600 90 1 5 Defines the name of the vendor that repairs this system DellStateSettings Read only COO Support Information Table Name Object ID Description Syntax Access cooSupportInformationTable 1 3 6 1 4 1 674 10892 1 1600 100 Defines the COO Support Information Table SEQUENCE OF cooSupport nformationTableE ntry Not accessible COO Support Information Table Entry Name Object ID Description Syntax Access Index cooSupportInformationTableEntry 1 3 6 1 4 1 674 10892 1 1600 100 1 Defines the COO Support Information Table entry cooSupportl nformationTableE ntry Not accessible cooSupportl nformationchassisl ndex cooSupportl nformation ndex 464 Cost of Ownership Group COO Support Information Chassis Index Name cooSupportiInformationchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Support Information Index Name cooSupportiInformationIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 2 Description Defines the index one based for this system s support information Syntax DellObjectR
441. on and off the power cycle capable host and shut down the operating system shutdown capable host manualRebootWithOSShutdow The operator can reboot with operating nCapable 16 system shutdown manualRebootWithoutOSShut downCapable 32 The operator can reboot without operating system shutdown manualPowerOffWithOSShutd The operator can power off with operating ownCapable 64 system shutdown manualPowerOffWithoutOSSh utdownCapable 128 The operator can power off without operating system shutdown manualPowerCycleWithOSShu tdownCapable 256 The operator can power cycle with operating system shutdown manualPowerCycleWithoutOs Shut downCapable 512 The operator can power cycle without operating system shutdown 114 Chassis Information Group Table 6 12 Host Control Settings Variable Name De 1 1HostControlSettings NOTE An operator can manually cause these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualReboot 1 The operator can reboot the host manualPowerOFF 2 The operator can power off the host manualPowerCycle 4 Power cycle the host manualOperatingSystemShutdown 8 The operator can shut down the operating system on the host manualOperatingSystemShutdownThe The operator can shut down the nPowerCycle 12 operating system on the host then power cycle machine Table 6 13 Watchdog Control Ca
442. on between each battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the Controller Table Controller Table This table describes available properties for each controller on the managed system The following object sets up the Controller Table Name controllerTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 Description D efines the controller table which is a table of managed Redundant Array of Independent disks RAID controllers The number of entries is related to the number of RAID controllers discovered in the system Syntax SEQUENCE OF ControllerEntry Access Not accessible Storage Management Group 563 Controller Entry Name controllerEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 Description Defines the controller table entry which is an entry in the table of RAID controllers A row in this table cannot be created or deleted by SNM P operations on columns of the table Syntax ControllerEntry Access Not accessible Index controllerN umber Controller Number Name controllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 1 Description Identifies the instance number of the controller entry Syntax Integer Access Read only Controller Name Name controllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 2 Description Identifies the name of the controller in this subsystem as represented in Storage M anagement Includes th
443. only Array Disk Length in Megabytes Name Object ID Description Syntax Access arrayDiskLengthInMB 1 3 6 1 4 1 674 10893 1 20 130 4 1 11 Identifies the size in megabytes of the array disk If this size isO it is smaller than a megabyte Integer Read only Array Disk Length in Bytes Name Object ID Description Syntax Access arrayDiskLengthInBytes 1 3 6 1 4 1 674 10893 1 20 130 4 1 12 Identifies the size of the array disk in bytes that is less than a megabyte T his size plus the arrayD iskL engthInM B is the total size of the array disk Integer Read only Storage Management Group 603 Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 13 Description The sizein megabytes of the largest contiguous free space on the array disk If this size is 0 it is less than a megabyte Syntax Integer Access Read only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte T his size plus the arrayD iskLargestC ontiguousF reeSpacel nM B is the total size of the largest contiguous free space on the array disk Syntax Integer Access Read only Array Disk Target ID Name arrayDiskTargetID Object ID 1 3 6 1 4
444. only Network Interface Control Index Name Object ID Description Syntax Access networkInterfaceControlIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 2 Defines the index one based of the network interface controller in this chassis DellObjectRange Read only 413 BIOS Setup Control Group Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 3 Description Defines the capabilities of the NIC Syntax DellN etworkl nterfaceC ontrolC apabilitiesU nique See Table 17 19 Access Read only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 4 Description Defines the control settings for the NIC Syntax DellN etworkl nterfaceC ontrolSettingsU nique See Table 17 20 Access Read write Network Interface Control Status Name networkInterfaceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 5 Description Defines the status of the NIC Syntax DellStatus Access Read only Network Interface Control Name Name networkInterfaceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 6 Description Defines the setup BIOS name of the NIC Syntax DellString Access Read only 414 BIOS Setup Control Group BIOS Setting Table These M IB objects enable you to track the BIOS settings for your system NOTE These MIB objects are supported on Dell PowerEdge xx2x
445. ontrolSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 32 Description Defines the current settings of the host control object Syntax DellH ostC ontrolSettings See Table 6 12 Access Read write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 33 Description Defines the capabilities of the watchdog timer object Syntax DellWatchD ogC ontrolC apabilities See Table 6 13 Access Read only Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 34 Description Defines the current settings and the values allowed to be set for the watchdog timer object Syntax DellWatchD ogC ontrolC apabilities See Table 6 13 Access Read write Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilities Unique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 35 Description Defines the capabilities of the watchdog expiry timer object Syntax DellWatchD ogT imerC apabilities See Table 6 13 Access Read only 80 Chassis Information Group Chassis Watchdog Control Expiry Time Name Object ID Description Syntax Access chassiswatchDogControlExpiryTime 1 3 6 1 4 1 674 10892 1 300 10 1 36 Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object DellU nsigned16BitRange Read write
446. oolean value that reports whether the power supply is capable of monitoring power consumption D ellBoolean Read only Power Group 157 Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 14 Description Defines the rated input wattage of the power supply in tenths of Watts Syntax D ellSigned32BitRange Access Read only Voltage Probe Table Name voltageProbeTable Object ID 1 3 6 1 4 1 674 10892 1 600 20 Description Defines the Voltage Probe Table Syntax VoltageProbeT ableE ntry Access Not accessible Voltage Probe Table Entry Name voltageProbeTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 Description Defines the Voltage Probe Table entry Syntax VoltageProbeT ableE ntry Access Not accessible Index voltageProbechassisl ndex voltageProbel ndex Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 158 Power Group Voltage Probe Index Name Object ID Description Syntax Access voltageProbeIndex 1 3 6 1 4 1 674 10892 1 600 20 1 2 Defines the index of voltage probes in this chassis DellObjectRange Read only Voltage Probe State Capabilities Name Object ID Description Syntax Access voltageProbeStateCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 3 Defines the capabiliti
447. ooling device in this chassis DellString Read only 204 Thermal Group Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 9 Description Defines the value of the fan s upper nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 10 Description Defines the value of the fan s upper critical threshold Syntax DellSigned32BitRange Access Read only Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 11 Description Defines the user assigned value of the fan s upper noncritical threshold Syntax D ellSigned32BitRange Access Read write Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 12 Description Defines the user assigned value of the fan s lower noncritical threshold Syntax DellSigned32BitRange Access Read write ThermalGroup 205 Cooling Device Lower Critical Threshold Name Object ID Description Syntax Access coolingDeviceLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 13 Defines the value of the fan s lower critical threshold DellSigned32BitRange Read only Cooling Device Lower Nonrecoverable Th
448. or Type Name monitorPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 7 Description Defines the connector type of the monitor port Syntax DellM onitorPortC onnectorT ypes See Table 13 5 Access Read only Monitor Port Name Name monitorPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 8 Description Defines the name of the monitor port Syntax DellString Access Read only Monitor Port BIOS Connector Type Name monitorPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 9 Description Defines the name of the BIOS connector type of the monitor port Syntax D ellG enericPortC onnectorType Access Read only PortGroup 241 Small Computer System Interface SCSI Port Table Name sCSIPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 60 Description Defines the SCSI Port Table Syntax IntegerSC SI PortTableE ntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 Description Defines the SCSI Port Table entry Syntax SC SI PortTableE ntry Access Not accessible Index sC SI Portchassis ndex sC SI PortIndex SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only SCSI Port Index Name sCSIPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 2 Description Defines the index of the SCSI
449. ork device DellU nsigned8BitRange Read only Network Device IRQ Name Object ID Description Syntax Access networkDeviceIRQ 1 3 6 1 4 1 674 10892 1 1100 90 1 20 Defines the interrupt request number of the network device DellU nsigned32BitRange Read only 308 Device Group Network Device Base 10 Port Address Name Object ID Description Syntax Access networkDeviceBaselOPortAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 21 Defines the base input outport port address of the network device DellU nsigned32BitRange Read only Network Device Teaming Flags Name Object ID Description Syntax Access networkDeviceTeamingFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 22 Defines the teaming features of the network device DellN etworkD eviceT eamingF lags see Table 14 21 Read only Network Device TOE Capability Flags Name Object ID Description Syntax Access networkDeviceTOECapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 23 Defines the TCP IP Offload Engine TOE capability flags of the network device DellN etworkD eviceT O EC apabilityF lags see Table 14 22 Read only Network Device TOE Enabled Name Object ID Description Syntax Access networkDeviceTOEEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 24 Defines if TOE is enabled for the network device DellBoolean Read only Device Group 309 Network Device RDMA Capability Flags Name Object ID Description
450. ormation Group Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 47 Description Defines the revision number of the system where zero indicates the original version of the system The revision number is not available on all systems Syntax D ellUnsigned8BitRange Access Read only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 48 Description Defines the revision name of the system if applicable Syntax DellString Access Read only Chassis Express Service Code Name Name chassisExpressServiceCodeNam Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 49 Description Defines the express service code of the chassis Syntax DellString Access Read only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier UUID Name uUIDTable Object ID 1 3 6 1 4 1 674 10892 1 300 20 Description Definesthe UUID table Syntax SEQUENCE OF UUIDTableEntry 84 Chassis Information Group Access uUIDTable Not accessible UUID Table Entry Name Object ID Description Syntax Access Index uUIDTableEntry 1 3 6 1 4 1 674 10892 1 300 20 1 Defines the UUID table entry UUID TableE ntry Not accessible uU ID Index uUID chassisl ndex UUID Chassis Index Name Object ID Description Syntax Access UUID Index Name Object ID Description Syntax Access
451. ot accessible Index cooM aintenancechassis ndex cooM aintenancel ndex 460 Cost of Ownership Group COO Maintenance Chassis Index Name Object ID Description Syntax Access cooMaintenancechassisIndex 1 3 6 1 4 1 674 10892 1 1600 80 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Maintenance Index Name Object ID Description Syntax Access cooMaintenanceIndex 1 3 6 1 4 1 674 10892 1 1600 80 1 2 Defines the index of this system s maintenance information DellObjectRange Read only COO Maintenance State Name Object ID Description Syntax Access cooMaintenanceState 1 3 6 1 4 1 674 10892 1 1600 80 1 3 Defines the state of this system s maintenance information DellStateSettings Read only COO Maintenance Start Date Name Name Object ID Description Syntax Access cooMaintenanceStartDateName 1 3 6 1 4 1 674 10892 1 1600 80 1 4 Defines the start date for maintenance on this system DellD ateN ame Read write Cost of Ownership Group 461 COO Maintenance End Date Name Name cooMaintenanceEndDateNam Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 5 Description Defines the end date for maintenance on this system Syntax DellD ateN ame Access Read write COO Maintenance Provider Name Name cooMaintenanceProviderNam Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 6 Description Defines the maintenance provider s name Syntax DellStateSettings Acce
452. otTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 Description Defines the System Slot Table entry Syntax IntegerSystemSlotTableE ntry Access Not accessible Index systemSlotchassisl ndex systemSlot ndex SlotGroup 349 System Slot Chassis Index Name systemSlotchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only System Slot Index Name systemSlot Index Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 2 Description Defines the index one based of the system slot in this chassis Syntax DellO bjectRange Access Read only System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 3 Description Defines the capabilities of the system slot Syntax D ellSystemSlotStateC apabilities See Table 15 1 Access Read only System Slot State Settings Unique Name systemSlotStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 4 Description Defines the state of the system slot Syntax DellSystemSlotStateSettings See Table 15 2 Access Read only 350 Slot Group System Slot Status Name Object ID Description Syntax Access systemSlotStatus 1 3 6 1 4 1 674 10892 1 1200 10 1 5 Defines the status of the system slot DellStatus Read only System Slot Current Usage Name Object ID Description Syntax Access System Slot Type Name
453. oup Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Amperage Probe Index Name amperageProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 2 Description Defines the index of amperage probes in this chassis Syntax DellObjectRange Access Read only Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 3 Description Defines the capabilities of the amperage probe Syntax DellStateC apabilities Access Read only Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 4 Description Defines the state and settings of the amperage probe Syntax DellStateSettings Access Read write 164 l Power Group Amperage Probe Status Name Object ID Description Syntax Access amperageProbeStatus 1 3 6 1 4 1 674 10892 1 600 30 1 5 Defines the status of the amperage probe DellSigned32BitRange Read only Amperage Probe Reading Name Object ID Description Syntax Access amperageProbeReading 1 3 6 1 4 1 674 10892 1 600 30 1 6 Defines the reading for an amperage probe of type other than amperageProbeTypel sD iscrete W hen the value for amperageProbeType is amperageP robeT ypel sPowerSupplyAmps or amperageProbeT ypel sSystemAmps the value
454. ower Supply Connection Entry Name Object ID Description Syntax Access Index powerSupplyConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 10 1 Defines the power supply connection table entry PowerSupplyC onnectionE ntry Not accessible powerSupplyC onnectionN umber Power Supply Connection Number Name Object ID Description Syntax Access powerSupplyConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 10 1 1 Identifies the instance number of the power supply connection entry Integer Read only Storage Management Group 631 Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 2 Description Identifies the name of the power supply in this connection as represented in Storage M anagement Syntax DisplayString Access Read only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 3 Description Identifies the instance number of the power supply in the powerSupplyTable in the connection Syntax Integer Access Read only Power Supply Connection Enclosure Name Name powerSupplyConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 4 Description Identifies the name of the enclosure as represented in Storage M anagement to which this power supply belongs Syntax DisplayString Access Read only Power Supply Connection Enclosure
455. owerSwitchchassisl ndex aC PowerSwitch ndex AC Power Switch Chassis Index Name Object ID Description Syntax Access aCPowerSwitchChassisIndex 1 3 6 1 4 1 674 10892 1 600 40 1 1 Defines the index one based of the chassis containing this AC power switch DellObjectRange Read only AC Power Switch Index Name Object ID Description Syntax Access aCPowerSwitchIndex 1 3 6 1 4 1 674 10892 1 600 40 1 2 Defines the index one based of this AC power switch DellObjectRange Read only Power Group 169 AC Power Switch Capabilities Name Object ID Description Syntax Access aCPowerSwitchCapabilities 1 3 6 1 4 1 674 10892 1 600 40 1 3 Defines the capabilities of this AC power switch DellAC PowerSwitchC apabilities Read only AC Power Switch Settings Name Object ID Description Syntax Access aCPowerSwitchSettings 1 3 6 1 4 1 674 10892 1 600 40 1 4 Defines the settings of this AC power switch DellAC PowerSwitchSettings Read write AC Power Switch Redundancy Status Name Object ID Description Syntax Access aCPowerSwitchRedundancyStatus 1 3 6 1 4 1 674 10892 1 600 40 1 5 Defines the redundancy status of this AC power switch DellStatusR edundancy Read only AC Power Cord Count for Redundancy Name Object ID Description Syntax Access 170 aCPowerCordCountForRedundancy 1 3 6 1 4 1 674 10892 1 600 40 1 6 Defines the total number of AC power cords required for thi
456. p destination can be disabled or enabled notReadyCapable 4 The SNMP trap destination can bein the not ready state Table 20 19 Remote SNMP Trap State Settings Variable Name De 1 1RemoteSNMPTrapStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state settings unknown 1 The SNMP trap destination state settings are unknown enabled 2 The SNMP trap destination is enabled notReady 4 The SNMP trap destination isin the not ready state Remote Access Group 519 Table 20 20 Remote SNMP Trap Control Capabilities Variable Name De 1 1RemoteSNMPTrapControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no control capabilities unknownCapabilities TheSNMP trap destination control capabilities are 1 unknown trapTestCapable 2 A SNMP trap test can be performed for the SNM P trap destination Table 20 21 Remote SNMP Trap Control Settings Variable Name De 1 1RemoteSNMPTrapControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no control settings unknown 1 The SNMP trap destination control settings are unknown trapTestCapable 2 ASNMP trap test is performed for the SNMP trap destination Table 20 22 Remote Dial Up Stat
457. pabilities Variable Name Del 1Wat chDogControlCapabilities NOTE When the system determines that the operating system is not responding it automatically performs the selected action without operator intervention Data Type Integer Possible Data Values Meaning of Data Value automat icReboot Capable 1 Watchdog controls can be set to reboot capable host automat icPowerCycleCapable 2 Watchdog controls can be set to power cycleable capable host automaticNotificationCapable 4 Watchdog controls can be set to notify capable host automat icWatchDogTimerCapable 8 Watchdog controls can be set to function automatically automat icPowerOffCapable 16 Watchdog controls can be set to automatically power off host Chassis Information Group 115 Table 6 13 Watchdog Control Capabilities continued Variable Name De 1 1Wat chDogControlCapabilities NOTE W hen the system determines that the operating system is not responding it automatically performs the selected action without operator intervention Data Type Integer Possible Data Values Meaning of Data Value automaticAllExceptNotificationCap Watchdog controls can be set to able 27 automatically perform all functions except notification capable automat icFullyCapable 31 Watchdog controls can be set to automatically perform all functions Table 6 14 Watchdog Control Settings Variable Name De 1 1WatchControlSett
458. pabilities Read only Power Usage State Settings Name Object ID Description Syntax Access powerUsageStateSettings 1 3 6 1 4 1 674 10892 1 600 60 1 4 Defines the state settings of the power usage information DellStateSettings Read write Power Usage Status Name Object ID Description Syntax Access powerUsageStatus 1 3 6 1 4 1 674 10892 1 600 60 1 5 Defines the status of the power usage information DellStatus Read only 177 Power Group Power Usage Entity Name Name Object ID Description Syntax Access powerUsageEntityName 1 3 6 1 4 1 674 10892 1 600 60 1 6 Defines the name of the entity associated with this power usage information DellString Read only Power Usage Cumulative Wattage Name Object ID Description Syntax Access powerUsageCumulativeWattage 1 3 6 1 4 1 674 10892 1 600 60 1 7 Defines the total wattage used in Watt hours by this entity since the date and time specified by the powerU sageC umulativeW attageStartD ateN ame attribute DellU nsigned32BitRange Read only Power Usage Cumulative Wattage Start Date Name Name Object ID Description Syntax Access powerUsageCumulativeWattageStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 8 Defines the date and time at which the data collection started for the value reported by the powerU sageC umulativeW attage attribute DellDateName Read only Power Usage Peak Watts Name Object ID po
459. pability notAvailable 4 Device does not have RDM A capability cannotBeDetermined 8 Querying for RDMA capability is supported but an error prevented querying driverNotResponding 16 Querying for RDMA capability is supported but driver did not respond to query Table 14 24 Network Device iSCSI Capability Flags Variable Name De 1 1NetworkDeviceiSCSICapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for iSC SI capability is not supported unknown 1 Querying for iSCSI capability is supported but query returned an error available 2 Device has iSC SI capability notAvailable 4 Device does not have iSCSI capability cannotBeDetermined 8 Querying for iSCSI capability is supported but an error prevented querying driverNotResponding 16 Querying for iSCSI capability is supported but driver did not respond to query Device Group 345 Table 14 25 Managed System Services Device Type Variable Name DellManagedSystemServicesDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value baseDevice 0 Device type is base device optionalDevice 1 Device type is optional device Table 14 26 SD Card Device Type Variable Name DellSDCardDeviceType Data Type Integer Possible Data Val
460. pe Name Object ID Description Syntax Access channelBusType 1 3 6 1 4 1 674 10893 1 20 130 2 1 11 The bus type of the channel Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 Serial Storage Architecture SSA 6 Universal Serial Bus USB 7 SATA 8 SAS Integer Read only Storage Management Group 587 Enclosure Table This table describes available properties for each enclosure on the managed system The following object sets up the Enclosure Table Name enclosureTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 Description Defines the enclosure table Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 Description Defines the enclosure table entry Syntax EnclosureE ntry Access Not accessible Index enclosureN umber Enclosure Number Name enclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 1 Description Identifies the instance number of the enclosure entry Syntax Integer Access Read only 588 Storage Management Group Enclosure Name Name Object ID Description Syntax Access enclosureName 1 3 6 1 4 1 674 10893 1 20 130 3 1 2 Identifies the enclosure s name as represented in Storage Management DisplayString Read only Enclosure Vendor Name Object ID Description Syntax Access enclosureVendor 1 3 6 1 4 1 674 10893 1 20 130 3 1 3 Identifies the enclosure s
461. pecified system detected an error from which it cannot recover The sensor location chassis location previous state and voltage sensor value are provided 704 l Traps Amperage Probe Traps Amperage probes measure the amount of current in amperes that is traversing critical components Table 27 6 Amperage Probe Traps TrapID Description Cause Amperage Probe Normal 1202 Current sensor returned to a normal value or Current sensor reading is withing range Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete C urrent sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt A current sensor on the power supply for the specified system returned to a valid range after crossing a failure threshold The sensor location chassis location previousstate and current sensor value are provided Amperage Probe Warning 1203 Current sensor detected a warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete C urrent sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt A current sensor on the power supply for the specified system exceeded its warning threshold T he sensor loca
462. pedAddressInterleaveDepth 1 3 6 1 4 1 674 10892 1 1100 60 1 9 Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address DellU nsigned32BitRange Read only Memory Device Mapped Address Starting Address Name Object ID Description Syntax Access memoryDeviceMappedAddressStartingAddress 1 3 6 1 4 1 674 10892 1 1100 60 1 10 Defines the physical starting address in KB of the memory device mapped address DellU nsigned64BitRange Read only Memory Device Mapped Address Ending Address Name Object ID Description Syntax Access memoryDeviceMappedAddressEndingAddress 1 3 6 1 4 1 674 10892 1 1100 60 1 11 Defines the physical ending address in KB of the memory device mapped address DellUnsigned64BitRange Read only Generic Device Table Name Object ID Description Syntax Access genericDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 70 Defines the Generic D evice Table SEQUENCE OF GenericD eviceTableE ntry Not accessible 294 Device Group Generic Device Table Entry Name Object ID Description Syntax Access Index genericDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 70 1 Defines the Generic D evice Table entry GenericD eviceTableEntry Not accessible genericD evicechassisl ndex genericD evicel ndex Generic Device Chassis Index Name Object ID Description
463. peratingSystemMemoryTotalPhysicalSize 1 3 6 1 4 1 674 10892 1 400 20 1 5 Defines the total physical memory size in kilobytes DellU nsigned32BitRange Read only Operating System Memory Available Physical Size Name Object ID Description Syntax Access operatingSystemMemoryAvailablePhysicalSize 1 3 6 1 4 1 674 10892 1 400 20 1 6 Defines the available physical memory size in kilobytes DellU nsigned32BitRange Read only Operating System Memory Total Page File Size Name Object ID Description Syntax Access operatingSystemMemoryTotalPageFileSize 1 3 6 1 4 1 674 10892 1 400 20 1 7 Defines the total page file memory size in kilobytes DellU nsigned32BitRange Read only Operating System Group 127 Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 8 Description Defines the available page file memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 9 Description Defines the total virtual memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 10 Description Defines the available virtual memory size in kilobytes Syntax Dell
464. plications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data This method has its drawbacks If it is done frequently significant amounts of network bandwidth can be consumed If it is done infrequently the response to the fault condition may not occur in atimely fashion SNM P traps avoid these limitations of the polling method An SNMP trap is an asynchronous event indicating that something significant has occurred T his is analogous to a pager receiving an important message except that the SNM P trap frequently contains all the information needed to diagnose a fault Two drawbacks to SNMP traps are that they are sent using UDP which is not a guaranteed delivery mechanism and that they are not acknowledged by the receiver An SNMP trap message contains the trap s enterprise OID the agent IP address a generic trap 1D the specific trap ID atime stamp and zero or more variable bindings varbinds The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator defined trap A varbind consists of an OID and its value and provides additional information about the trap In order for a management system to receive SN MP traps from a managed system the node must be configured to send traps to the management system Trap destination configuration is dependent on the operating system W hen this configuration is done a management
465. plug system slot D ellSystemSlotH otPlugBusW idth See Table 15 7 Read only Slot Group System Slot Hot Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 13 Description Defines the slot speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitR ange Access Read only System Slot Hot Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 14 Description Defines the adapter speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitRange Access Read only System Slot Variable Values This section includes definitions for server administrator specific variable values used in this section Table 15 1 System Slot State Capabilities Variable Name De11SystemSlotStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown The system slot s capabilities are unknown 1 systemSlotHotPlugIsHotPlug The system slot supports hot plug gableCapable 2 systemSlotHotPlugCanBePower The system slot power and corresponding edon 4 light emitting diode LED can be powered on SlotGroup Table 15 1 System Slot State Capabilities continued Variable Name De11SystemSlotStateCapabilities Data Type Integer Possible Data Values
466. ply probe with reading in Amperes amperageProbeTypelsPowerSupplyWatts 24 The amperage probe type is power supply probe with reading in Watts amperageProb TypelIsSystemAmps 25 The amperage probe type is system probe with reading in Amperes amperageProbeTypelsSystemWatts 26 The amperage probe type is system probe with reading in Watts Table 9 9 Amperage Probe Discrete Reading Variable Name DellAmperageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value amperagelsGood 1 The amperage probe discrete reading is good amperagelIsBad 2 The amperage probe discrete reading is bad 192 Power Group Table 9 10 AC Power Switch Capabilities Variable Name De 1 1ACPowerSwitchCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknownCapabilities 1 TheAC power switch s capabilities are unknown input SourceCord1NoReturnCapable 2 Input source is AC power cord 1 with no return inputSourceCord1ReturnCapable 4 Input source is AC power cord 1 with return input SourceCord2NoReturnCapable 8 Input source is AC power cord 2 with no return input SourceCord2ReturnCapable 16 Input source is AC power cord 2 with return input SourceSharedCapable 32 Input source is shared Table 9 11 AC Power Switch Settings Variable Name De 1 1ACPowerSwitchSettings
467. plyConfigurationErrorType Data Type Integer Possible Data Values Meaning of Data Value vendorMismatch 1 The power supply configuration error type is vendor mismatch revisionMismatch 2 The power supply configuration error type is revision mismatch processorMissing 3 The power supply configuration error type is processor missing Table 9 6 Voltage Probe Type Variable Name De11VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelIsOther 1 The voltage probe type is not one of the following voltageProbeTypelsUnknown 2 The voltage probe type is unknown not known or not monitored voltageProbeTypelIs1lPoint5Volt The voltage probe type is a 1 5 volt V 3 probe voltageProbeTypels3Point3Volt The voltage probe type is a 3 3 V probe 4 voltageProbeTypels5Volt 5 The voltage probe type is a 5 V probe voltageProbeTypeIsMinus5Volt The voltage probe type is a 5 V probe 6 voltageProbeTypelIs12Volt 7 The voltage probe type is a 12 V probe voltageProbeTypelIsMinus12Volt The voltage probe type is a 12 V probe 8 voltageProbeTypelsI0 9 The voltage probe type is an I O volt probe Power Group 189 Table 9 6 Voltage Probe Type continued Variable Name De11VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelIsCore 10 The voltage pro
468. power cord s state is disabled offline 0 or enabled online 1 notReady 4 The AC power cord s state is not ready acPowerCordHasPower TheAC power cord has power 8 acPowerCordIsActive TheAC power cord is the active source of Source 16 AC power 194 Power Group Table 9 15 Battery Reading Variable Name De 1 1BatteryReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value predictiveFailure 1 Battery sensor detects predictive failure failed 2 Battery has failed presenceDetected 4 Battery presence is detected Table 9 16 Power Cap Capabilities Variable Name De 1 1PowerCapCapabilities Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value none 0 No power cap capabilities are available enable 1 Power cap can be enabled disable 2 Power cap can be disabled Table 9 17 Power Cap Setting Variable Name De 1 1PowerCapSetting Data Type Integer Possible Data Values Meaning of Data Value disabled 0 Power cap is disabled enabled 1 Power cap is enabled Power Group 195 Table 9 18 Power Profile Type Variable Name De 1 1PowerProfileType Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Val
469. prise specific Traps continued TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1019 alertDrscSEL TheRAC M ajor Status RAC All 100 system event detected percentF ull log is 100 system event full log is 100 full 1020 alerttDrscSEL TheRAC Information Error RAC All Normal has detected detected a a new event new system in the event logwith System normal Event Log severity with detailed log Severity info isin Normal drsAlert M essage varbind BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds All of the traps documented in this section belong to the M IB enterprise identified by OID 1 3 6 1 4 1 3183 1 1 1 Table 27 20 BMC Traps TrapID Description Severity 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 131330 Under Voltage Problem Lower Critical going low Critical 131458 Under Voltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 726 Traps Table 27 20 BMC Traps continued TrapID Description Severity 131840 Generic Critical Voltage Problem Cleared Information 65792 U nder Temperature Warning Lower non critical Warning going low 65920 Under
470. processor 3xxx Series deviceFamilyIsQuadCoreIntelXeo n3xxx 216 The processor family is Quad C ore Intel Xeon processor 3xxx Series deviceFamilyIsVIANano 217 The processor family is VIA Nano deviceFamilyIsDualCoreIntelXeo n5xxx 218 The processor family is D ual C ore Intel Xeon processor 5xxx Series deviceFamilyIsQuadCoreIntelXeo n5xxx 219 The processor family is Quad C ore Intel Xeon processor 5xxx Series deviceFamilyIsDualCoreIntelXeo n7xXxx 221 The processor family is D ual C ore Intel Xeon processor 7xxx Series deviceFamilyIsQuadCoreIntelXeo n7xxx 222 The processor family is Quad C ore Intel Xeon processor 7xxx Series deviceFamilyIs on7xxx 223 MultiCoreIntelXe The processor family is M ulti C ore Intel Xeon processor 7xxx Series deviceFamilyIs on3400 224 ultiCoreIntelXe The processor family is M ulti C ore Intel Xeon processor 3400 Series deviceFamilyIsEmbeddedAMDOpert onQuadCore 230 The processor family is Embedded AMD Opteron Quad C ore deviceFamilyIsA ore 231 DPhenomTriplec The processor family is AMD Phenom Triple C ore deviceFamilyIsA alCoreMobile 232 DTurionUltraDu The processor family is AM D Turion Ultra Dual C ore mobile processor deviceFamilyIsA eMobile 233 DTurionDualCor The processor family is AM D Turion D ual C ore mobile processor deviceFa
471. provides status and identifying information about a system s operating system Identifying information includes the name version service pack and patch level of the installed operating system Operating System Group Table The following management information base M IB tables define the objects in the Operating System Group e Operating System Table on page 123 e Operating System Memory Table on page 125 Operating System Table The following object sets up the Operating System Table Name operatingSystemTable Object ID 1 3 6 1 4 1 674 10892 1 400 10 Description Defines the O perating System Table Syntax SEQUENCE OF OperatingSystemTableE ntry Access Not accessible Operating System Table Entry Name operatingSystemTableEntry Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 Description Defines the O perating System Table entry Syntax OperatingSystemTableE ntry Access Not accessible Index operatingSystemchassis ndex Operating System Group 123 Operating System Chassis Index Name Object ID Description Syntax Access operatingSystemchassisIndex 1 3 6 1 4 1 674 10892 1 400 10 1 1 Defines the index one based of the associated chassis DellO bjectRange Read only Operating System State Capabilities Name Object ID Description Syntax Access operatingSystemStateCapabilities 1 3 6 1 4 1 674 10892 1 400 10 1 2 Defines the capabilities of the operating system DellStateC apabilities Read only Oper
472. ption Defines the IP address of the update server providing the firmware image used by the remote access hardware Syntax pAddress Access Read write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 24 Description Defines the file name of the firmware image obtained from the update server used by the remote access hardware Syntax DisplayString SIZE 0 255 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read write Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read write 484 Remote Access Group Remote Access NIC Static Gateway Address Name Object ID Description Syntax Access remoteAccessNICStaticGatewayAddress 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware pAddress Read write Remote A
473. r Name arrayDiskEnclosureConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 1 Description Identifies the instance number of the array disk enclosure connection entry Syntax Integer Access Read only Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 2 Description Identifies the name of the array disk in this connection as represented in Storage M anagement Syntax DisplayString Access Read only Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 3 Description Identifies the instance number of the array disk in the arrayD iskTable in this connection Syntax Integer Access Read only Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 4 Description Identifies the name of the enclosure as represented in Storage M anagement to which this array disk belongs Syntax DisplayString Access Read only 614 Storage Management Group Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs Syntax Integer Access Read only
474. r U sage Table 176 variable values 185 Voltage Probe Table 158 Power Group tables 151 Processor Device Status Traps 736 Index 803 Processor sensor detected a failure value 737 Processor sensor detected a warning value 736 737 Processor sensor returned to a normal state 736 Redundant Memory Unit Table 376 Remote Access Group Remote Access Table 478 Remote SNMP Trap Table 495 Remote User Administration Table 487 Remote U ser Dial In Configuration Table 504 Remote User Dial O ut Table 507 Remote Flash BIOS Group variable values 224 S sample SNMP output 795 Slot Group System Slot Table 349 variable values 353 SNMP introduction to 33 SNMP MIB OIDs 35 SNMP security 36 SNMP traps 37 804 Index SNMP basic terminology fields 27 28 managed object 26 MIB 26 SNMP 25 variable 26 SNMP support configuring 755 SNMP tables 29 example 29 reference guide content 31 36 SNMP traps 757 Storage M anagement Event Group 669 Storage M anagement Information Group 555 System Resource Group Direct M emory Access Table 143 Input Output Port Table 134 Interrupt Table 140 Map Table 129 Memory Table 137 Owner Table 131 variable values 146 System State Table 49 51 349 systems management software 43 build number systems 44 description name 44 name 44 46 preferred protocol 45 supported protocol 45 version number name 44 T V Thermal Gro
475. r response to prevent damage to the system State refers to the condition of an object that has more than one condition For example an object may be in a not ready or in an enabled state Status refers to the health of an object or how the object is functioning For example the status of a temperature probe that is measuring acceptable temperatures would be reported as normal W hen the probe begins reading temperatures that exceed limits set by the user it reports a critical status 28 Introduction Tables This reference guide contains two types of tables tables that are used to organize and define variable values and tables that define M IB objects Readers must understand the difference between these two types of tables SNMP Tables M ost of the MIB objects defined in this reference guide are organized into SNMP tables SN MP tables organize data into two dimensional structural arrays In SNMP objects that have a relationship to other objects are called columnar objects C olumnar objects are objects used to form lists and tables W hen aM IB group is divided into one or more discrete tables the word table has a technical meaning An example is the section of this reference guide entitled Universal Unique Identifier UUID The UUID object has a type and a value that uniquely identifies an object such as a chassis The table defines all of the variables that comprise the managed object UUID The following table is an example of
476. r way set ciative 5 associative deviceAssociativityIsFullyAssociative Device is fully associative 6 deviceAssociativityIsEightWaySetAsso Deviceis eight way set ciative 7 associative deviceAssociativityIsSixteenWaySet Device is sixteen way set Associative 8 associative deviceAssociativityIsl2WaySetAssoc Device is12 way iative 9 Set Associative deviceAssociativityIs24WaySetAssoc Device is24 way iative 10 Set Associative deviceAssociativityIs32WaySetAssoc Deviceis 32 way iative 11 Set Associative deviceAssociativityIs48WaySetAssoc Deviceis 48 way iative 12 Set Associative deviceAssociativityIs64WaySetAssoc Deviceis 64 way iative 13 Set Associative DeviceGroup 337 Table 14 13 Cache Device Location Variable Name De 1 1CacheDeviceLocation Data Type Integer Possible Data Values Meaning of Data Value deviceLocationIsOther 1 Device location is not one of the following deviceLocationIsUnknown 2 Device location is unknown deviceLocationIsInternal 3 Device location is internal deviceLocationIsExternal 4 Device location is external Table 14 14 Cache Device Static Random Access Memory SRAM Type Variable Name De 1 1 CacheDeviceSRAMType Data Type Integer Possible Data Values Meaning of Data Value deviceSRAMTypelIsOther 1 Device SRAM type is not one of the following
477. rNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 14 Defines the value of the physical memory array ECC error noncritical threshold DellSigned32BitRange read write MemoryGroup 367 Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 15 Description Defines theindex to the associated Redundant M emory Unit in this chassis Syntax DellObjectRange Access Read only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses The following object sets up the Physical M emory Array M apped Table Name physicalMemoryArrayMappedTable Object ID 1 3 6 1 4 1 674 10892 1 1300 20 Description Defines the Physical Memory Array M apped Table Syntax PhysicalM emoryArrayM appedTableE ntry Access Not accessible Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1300 20 1 Description Defines the Physical M emory Array M apped Table entry Syntax PhysicalM emoryArrayM appedTableE ntry Access Not accessible Index physicalM emoryArrayM appedchassis ndex physicalM emoryArrayM apped ndex 368 Memory Group Physical Memory Array Mapped Chassis Index Name Object ID Description Syntax Access physicalMemoryArrayMappedchassisIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 1 Defines the index one bas
478. re unknown The logging capabilities are enableCapable 2 Logging enable disable using Simple Network M anagement Protocol SNM P is supported 386 Memory Group Table 16 8 Physical Memory Logging Settings Variable Name De 1 1 PhysicalMemoryLoggingSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no logging settings enabled unknown Capabilities 1 Logging capabilities are unknown The logging settings are enabled 2 Logging is disabled 0 or enabled 1 MemoryGroup 387 388 Memory Group BIOS Setup Control Group Basic Input Output System BIOS Setup Control Group variables provide information about the functions that the BIOS performs in your system This management information base M IB group includes variables for the boot sequence speakers diskettes ports network interface controllers NICs and the Wakeup on local area network LAN feature BIOS Setup Control Group Tables The MIB tables in this group define the BIOS control of devices and controller cards that are typically present in a system BIOS Setup Control Table on page 389 SCSI Control Table on page 400 e Parallel Port Control Table on page 402 Serial Port C ontrol Table on page 404 USB Control Table on page 406 IDE Control Table on page 408 Diskette Control Table on page 410 Network Interface Control Table on pag
479. rectable M emory Event Clear the memory error on Uncorrectable Memory Event Replace the memory module identified in the message during the system s next scheduled maintenance The memory device status and location are provided Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis Table 27 11 Fan Enclosure Traps TrapID Description Severity Cause Fan Enclosure Insertion 1452 Fan enclosure inserted into Information A fan enclosure has been system inserted into the specified Sensor location lt L ocation in system T he sensor chassis gt location and chassis location are provided Chassis location lt N ame of chassis gt 712 l Traps Table 27 11 Fan Enclosure Traps continued TrapID Description Severity Cause Fan Enclosure Removal 1453 Fan enclosure removed from Warning system Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt A fan enclosure has been removed from the specified system T he sensor location and chassis location are provided Fan Enclosure Extended Removal 1454 Fan enclosure removed from Error system for an extended amount of time Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt A fan enclosure has been removed
480. reshold Name Object ID Description Syntax Access coolingDeviceLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 14 Defines the value of the fan s lower nonrecoverable threshold DellSigned32BitRange Read only Cooling Device Cooling Unit Index Reference Name Object ID Description Syntax Access coolingDevicecoolingUnitIndexReference 1 3 6 1 4 1 674 10892 1 700 12 1 15 Defines the index for the associated system cooling unit in this chassis DellO bjectRange Read only Cooling Device Subtype Name Object ID Description Syntax Access coolingDeviceSubType 1 3 6 1 4 1 674 10892 1 700 12 1 16 Defines the cooling device subtype DellC oolingD eviceSubType See Table 10 2 Read only 206 Thermal Group Cooling Device Probe Capabilities Name Object ID Description Syntax Access coolingDeviceProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 17 Defines the probe capabilities of the cooling device DellProbeC apabilities Read only Cooling Device Discrete Reading Name Object ID Description Syntax Access coolingDeviceDiscreteReading 1 3 6 1 4 1 674 10892 1 700 12 1 18 Defines the reading for a voltage probe of type coolingD eviceSubTypelsbD iscrete W hen the value for coolingD eviceSubType is other than coolingD eviceSubTypelsD iscrete a value is not returned for this attribute W hen the value for coolingD eviceSubType is coolingD eviceSubTypelsD iscre
481. ress Gen 2 x2 358 Slot Group Table 15 3 System Slot Type continued Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4 174 Thesystem slot type is PCI Express Gen 2 x4 systemSlotIsPCIExpressGen2X8 175 Thesystem slot type is PCI Express Gen 2 x8 systemSlotIsPCIExpressGen2X16 176 Thesystem slot type is PCI Express Gen 2 x16 Table 15 4 System Slot Usage Variable Name De11SystemSlotUsage Data Type Integer Possible Data Values Meaning of Data Value systemSlotUsagelIsOther 1 The system slot usage is not one of following systemSlotUsageIsUnknown 2 The system slot usage is unknown systemSlotUsageIsAvailable 3 The system slot is available systemSlotUsageIsInUse 4 The system slot isin use Table 15 5 System Slot Length Variable Name Del 1SystemSlotLength Data Type Integer Possible Data Values Meaning of Data Value systemSlotLengthIsOther 1 The system slot length is not one of following systemSlotLengthIsUnknown 2 Thesystem slot length is unknown systemSlotLengthIsShort 3 The system slot length is short systemSlotLengthIsLong 4 The system slot length is long SlotGroup 359 Table 15 6 System Slot Category Variable Name De11SystemSlotCategory Data Type Integer Possible Data Values Meaning of Data Value systemSlot
482. revious state was lt State gt Fan sensor value lt Reading gt A fan sensor in the specified system detected the failure of one or more fans The sensor location chassis location previous state and fan sensor value are provided Cooling Device Non recoverable 1105 Fan sensor detected a Error non recoverable value Sensor location lt Location in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt Fan sensor value lt R eading gt A fan sensor detected an error from which it cannot recover The sensor location chassis location previous state and fan sensor value are provided 702 Traps Voltage Probe Traps Voltage probes monitor the number of volts across critical components Table 27 5 Voltage Probe Traps TrapID Description Severity Cause Voltage Probe Normal 1152 Voltage sensor returned to a normal value Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt Information A voltage sensor in the specified system returned to a valid range after crossing a failure threshold T he sensor location chassis location previous state and voltage sensor value are provided Voltage Probe Warning 1153 Voltage sensor detected a warning val
483. ries 754 G Global Data Group 556 Introduction Server Administrator C hange Management MIB 23 Server Administrator Instrumentation MIB 18 Server Administrator Remote Access MIB 21 Server Administrator Storage Management MIB 22 Inventory 673 Inventory Group 673 L Local Response Agent Group LRA Action Table 432 LRA Global Settings 429 LRA Global Settings Table 430 variable values 434 Local Response Agent Group tables 429 Logical Devices Group 656 Memory device correction rate crossed a warning threshold 731 Memory device ECC Correctable error count crossed a warning threshold 731 Memory Group Physical M emory Tables 363 variable values 371 378 Memory Group Variable Values 382 MIB minor version number 42 MIB Major Version Number 41 0 Operating System Group 679 Memory Table 125 Operating System Table 123 Operating System M emory Table 125 P Physical Devices Group 562 Physical Memory Card Table 379 Pluggable D evice Traps 738 Port Group Keyboard Port Table 230 Memory Device Port Table 236 Monitor Port Table 239 Parallel Port Table 244 Pointing Port Table 227 Processor Port Table 233 Serial Port Table 248 Small Computer System Interface Port Table 242 variable values 255 Power Group AC Power Cord Table 171 AC Power Switch Table 169 Amperage Probe Table 163 Battery Table 174 Power Supply Table 154 Power Unit Table 151 Powe
484. ription Defines the cooling unit name in this chassis Syntax DellString Access Read only Cooling Unit Status Name coolingUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 8 Description Defines the status of the cooling unit in this chassis Syntax DellStatus Access Read only ThermalGroup 201 Cooling Device Table Name Object ID Description Syntax Access coolingDeviceTable 1 3 6 1 4 1 674 10892 1 700 12 Defines the Cooling Device Table CoolingD eviceTableE ntry Not accessible Cooling Device Table Entry Name Object ID Description Syntax Access Index coolingDeviceTableEntry 1 3 6 1 4 1 674 10892 1 700 12 1 Defines the Cooling D evice Table entry CoolingD eviceTableE ntry Not accessible cooling D evicechassisl ndex coolingD evicel ndex Cooling Device Chassis Index Name Object ID Description Syntax Access coolingDevicechassisIndex 1 3 6 1 4 1 674 10892 1 700 12 1 1 Defines the index one based of this chassis DellO bjectRange Read only Cooling Device Index Name Object ID Description Syntax Access coolingDeviceIndex 1 3 6 1 4 1 674 10892 1 700 12 1 2 Defines the index of cooling devices in this chassis DellO bjectRange Read only 202 Thermal Group Cooling Device State Capabilities Name Object ID Description Syntax Access coolingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 3 Defines the capabilities of the cooling device DellStat
485. rmal trip The sensor location chassis location previous state and processor sensor status are Previous state was lt State gt provided Processor sensor status lt status gt Chassis Location lt Name of chassis gt Traps 717 Pluggable Device Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards D evice traps provide information about the addition and removal of such devices Table 27 15 Pluggable Device Traps TrapID Description Severity Cause Pluggable Device Addition 1651 Device added to system Information Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt A device was added to the specified system The device location chassis location and additional event details if available are provided Pluggable Device Configuration Error 1653 Device configuration error Error detected Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt A configuration error was detected for a pluggable device in the specified system The device may have been added to the system incorrectly The device location chassis location and additional event details if available are provided Pluggable Device Removal 1652 Device removed from Information system Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt A devic
486. rnalClockSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 13 Description Defines the speed of the external clock the front side bus speed for the processor device in M Hz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only 270 Device Group Processor Device Voltage Name processorDeviceVoltag Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 14 Description Defines the voltage powering the processor device in millivolts A zero 0 indicates the speed is unknown Syntax DellSigned32BitRange Access Read only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 15 Description Defines the processor upgrade information for the processor device Syntax DellProcessorU pgradel nformation See Table 14 5 Access Read only Processor Device Version Name Name processorDeviceVersionName Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 16 Description Defines the version name of the processor device Syntax DellString Access Read only Device Group 271 Processor Device Core Count Name processorDeviceCoreCount Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 17 Description Defines the number of processor cores detected for the processor device Syntax DellU nsigned32BitRange Access Read only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1 3 6 1 4 1 674 10892 1 1100
487. robe amperageProbeTypels5Volt 5 The amperage probe typeisa 5 A probe amperageProbeTypelsMinus5Volt 6 The amperage probe typeisa 5 A probe amperageProbeTypels12Volt 7 The amperage probe typeisa 12 A probe amperageProbeTypelIsMinus12Volt 8 The amperage probe typeisa 12 A probe amperageProbeTypelIsI10 9 The amperage probe type is an 1 0 amperage probe amperageProbeTypelsCore 10 The amperage probe typeisa core amperage probe amperageProbeTypelsFLEA 11 The amperage probe typeisa FLEA standby amperage probe amperageProbeTypelsBattery 12 The amperage probe typeisa battery amperage probe amperageProbeTypelIsTerminator 13 The amperage probe typeisa Small Computer System Interface SC SI termination amperage probe 191 Power Group Table 9 8 Amperage Probe Definitions continued Variable Name De 1 1AmperageTyp Data Type Integer Possible Data Values Meaning of Data Value amperageProb TypelIs2Point5Volt 14 The amperage probe typeisa 2 5 V amperage probe amperageProb TypeIsGTL 15 T he amperage probe type is a Gunning Transceiver Logic GTL probe amperageProb TypelIsDiscrete 16 The amperage probe type is an amperage probe with discrete reading amperageProbeTypelsPowerSupplyAmps 23 The amperage probe type is power sup
488. rocessorUpgradelIsBySocketF 24 Upgrade is by Socket F 1207 processorUpgradeIsBySocketLGA1366 25 Upgrade is by Socket LGA1366 Table 14 6 Processor Device Family Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsOther 1 The processor family is not one of the following values deviceFamilyIsUnknown 2 The processor family is unknown deviceFamilyIs8086 3 The processor family is 8086 deviceFamilyIs80286 4 The processor family is 80286 deviceFamilyIs80386 5 The processor family is 80386 deviceFamilyIs80486 6 The processor family is 80486 deviceFamilyIS8087 7 The processor family is 8087 324 Device Group Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamily1Is80287 8 The processor family is 80287 deviceFamilyIs80387 9 The processor family is 80387 deviceFamilyIs80487 10 The processor family is 80487 deviceFamilyIsPentium 11 The processor family is Intel Pentium deviceFamilyIsPentiumPro 12 The processor family is Pentium Pro deviceFamilyIsPentium2 13 The processor family is Pentium II deviceFamilyIsPent iumMMx 14 The processor family is Pentium M M X deviceFamilyIsCeleron 15 The processor family is C eleron deviceFamilyIsXeon
489. roup Physical Memory Card Table This table defines the name of the memory card the total number of device slots present on the memory card and the number of memory device slots in use on the memory card The following objects set up the Physical M emory C ard Table Physical Memory Card Table Name Object ID Description Syntax Access physicalMemoryCardTable 1 3 6 1 4 1 674 10892 1 1300 60 Defines the Physical M emory C ard Table SEQUENCE OF PhysicalM emoryC ardTableE ntry Not accessible Physical Memory Card Table Entry Name Object ID Description Syntax Access Index physicalMemoryCardTableEntry 1 3 6 1 4 1 674 10892 1 1300 60 1 Defines the Physical Memory Card Table Entry PhysicalM emoryC ardTableE ntry Not accessible physicalM emoryC ardC hassisI ndex physicalM emoryC ardl ndex Physical Memory Card Chassis Index Name Object ID Description Syntax Access physicalMemoryCardChassisIndex 1 3 6 1 4 1 674 10892 1 1300 60 1 1 Defines the index one based of the associated chassis DellO bjectRange Read only MemoryGroup 379 Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1 3 6 1 4 1 674 10892 1 1300 60 1 2 Description Defines the index one based of the Physical Memory C ard Syntax DellO bjectRange Access Read only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1300 60 1 3 Description Defin
490. roup 199 Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 1 Description Defines the index one based of this chassis Syntax TableE ntry Access Read only Cooling Unit Index Name coolingUnitIndex Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 2 Description Defines the index one based of cooling units Syntax DellO bjectRange Access Read only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 3 Description Defines the capabilities of the cooling unit Syntax DellStateC apabilities Access Read only Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 4 Description Defines the state and settings of the cooling unit Syntax DellStateSettings Access Read write 200 Thermal Group Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 5 Description Defines the redundancy status of the cooling unit Syntax DellStatusR edundancy Access Read only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy Syntax DellO bjectRange Access Read only Cooling Unit Name Name coolingUnitName Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 7 Desc
491. rtPMESig nal 16384 The system slot can support Power Management Enable PME signal canSupportAllSlotCapabilit ies 32640 The system slot can support all slot capabilities 354 Slot Group Table 15 2 System Slot State Settings Variable Name De11SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown 1 The system slot s capabilities are unknown systemSlotHotPlugIsHotPluggable 2 Thesystem slot supports hot plug systemSlotHotPlugIsPoweredOn 4 The system slot power and corresponding LED can be powered on systemSlotHotPlugIsAtAttention 8 Thesystem slot attention state and corresponding LED can be set systemSlotHotPlugIsHotPluggable 2 The system slot supports hot plug systemSlotHotPlugIsPoweredoOn 4 The system slot power and corresponding LED ison systemSlotHotPlugIsAtAttention 8 Thesystem slot attention state and corresponding LED is on systemSlotHotPlugHasPowerFaulted Poweron fault and corresponding 16 LED was detected due to a short or overcurrent systemSlotHotPlugAdapterIsPresent Adapter card present in slot 32 may not be powered systemSlotHotPlugAdapterPresentAnd Adapter card present in slot PoweredOn 36 and powered systemSlotHotPlugPowerButtonPressed The system slot power button 64 pressed to signal a toggle of the power sta
492. rusion status of all intrusion detection devicesin this chassis T he result is returned as a combined status value T he value has the same definition type as D ellStatus DellStatus Read only System State Chassis Intrusion Status Details Name Object ID Description Syntax Access systemStateChassisIntrusionStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 31 Defines the intrusion status of all intrusion detection devicesin this chassis The first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on Octet String Size 1 128 Read only 61 System State Group System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 32 Description Defines the individual state of all AC power switches in this chassis The first byte returned represents the state of the first AC power switch the second byte returned represents the state of the second AC power switch and so on Syntax Octet String Size 1 128 Access Read only System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 33 Description Defines the overall redundancy status of the AC power switches in this chassis Syntax DellStatusR edundancy Access Read only System State AC Power Switch Statu
493. s 757 Alert Descriptions and Corrective Actions 757 29 IDR ACT MB oie on ord oS etd Hs 759 Supported Systems 759 Blade Servers 20000 5 759 Rack and TowerServers 759 iDRAC7 Supported SNMP Versions 759 iDRAC7 Out of BandGroup 760 RAC Information Group 760 Chassis InformationGroup 762 System InformationGroup 762 Status Group waa ob ey we te a a aes 766 iDRAC7 Traps 0 4 767 Trap Variables 2 ee ee ee eee 768 SystemTrapGroup 769 Storage Trap Group 781 Updates Trap Group 00006 786 AuditTrapGroup 2 00 786 Configuration Trap Group 787 A Standard Data Type Definitions 789 Common DataTypes 789 Variables with Data Types of State Capabilities and State Capabilities Unique 790 Dell Status Data Types 792 Dell Date sen ee yp Ra eR a es 793 FullDates 0 0 794 Contents 14 Contents Contents 15 16 Contents Introduction This reference guide provides information about the Simple N etwork Management Protocol SNMP Management Information Base M IB which is applicable for Dell O penM anage Version 7 0 K NOTE This guide contains information that may also be applicable to earlier OpenM anage supported platforms This intro
494. s Syntax DellO bjectRange Access Read only User Security Index Name userSecurityIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 2 Description Defines the user security index Syntax DellO bjectRange Access Read only User Security User Name Name userSecurityUserName Object ID 1 3 6 1 4 1 674 10892 1 800 1 3 Description Defines the user security user name Syntax DellSecurityString Access Read only User Security Control Name Name userSecurityControlName Object ID 1 3 6 1 4 1 674 10892 1 800 1 4 Description Defines a control name used for creating deleting and editing users Syntax DellSecurityString Access Read write 218 User Security Group User Security Request Name Name userSecurityRequestName Object ID 1 3 6 1 4 1 674 10892 1 800 1 5 Description Defines a request name used for creating deleting and editing users Syntax DellSecurityString Access Read write User Security Group 219 220 User Security Group Remote Flash BIOS Group The Remote Flash Basic Input O utput System BIOS Table defines the variables used to remotely update the BIOS in a system The variables also define the capabilities of BIOS updates on the system Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table Name remoteFlashBlIOSTable Object ID 1 3 6 1 4 1 674 10892 1 900 10
495. s AC power switch to have redundancy DellObjectRange Read only Power Group AC Power Switch Name Name Object ID Description Syntax Access aCPowerSwitchName 1 3 6 1 4 1 674 10892 1 600 40 1 7 Defines the name of this AC power switch DellString Read only AC Power Switch Redundancy Mode Name Object ID Description Syntax Access aCPowerSwitchRedundancyMode 1 3 6 1 4 1 674 10892 1 600 40 1 8 Defines the redundancy mode of this AC power switch DellAC PowerSwitchRedundancyM ode Read write AC Power Switch Status Name aCPowerSwitchStatus Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 9 Description Defines the status of this AC power switch Syntax DellStatus Access Read only AC Power Cord Table Name aCPowerCordTable Object ID 1 3 6 1 4 1 674 10892 1 600 42 Description Defines the AC Power C ord Table Syntax SEQUENCE OF AC PowerC ordTableE ntry Access Not accessible Power Group 171 AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 Description Defines the AC Power C ord Table entry Syntax AC PowerC ordTableEntry Access Not accessible Index aC PowerC ordchassisl ndex aC PowerC ordl ndex AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 1 Description Defines the index one based of the chassis containing this AC power cord Syntax DellObjectRange Access Read only AC Power Cord Ind
496. s Details Name systemStateACPowerSwitchStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 34 Description Defines the individual status of all AC power switches in this chassis T he first byte returned represents the status of the first AC power switch the second byte returned represents the status of the second AC power switch and so on Syntax Octet String Size 1 128 Access Read only 62 System State Group System State AC Power Cord State Details Name Object ID Description Syntax Access systemStateACPowerCordStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 35 Defines the individual state of all AC power cords for any AC power switches in this chassis T he first byte returned represents the state of the first AC power cord the second byte returned represents the state of the second AC power cord and so on Octet String Size 1 128 Read only System State AC Power Cord Status Combined Name Object ID Description Syntax Access systemStateACPowerCordStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 36 Defines the overall status of all AC power cords for any AC power switches in this chassis DellStatus Read only System State AC Power Cord Status Details Name Object ID Description Syntax Access systemStateACPowerCordStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 37 Defines the individual status of all AC power cords for any AC power switches in this chassis The first
497. s Information Group 75 Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 16 Description Defines the boot time of this system Syntax DellD ateN ame Access Read only Chassis System Date Name Name chassisSystemDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 17 Description Defines the current time on this system Syntax DellD ateN ame Access Read only Chassis System Location Name Name chassisSystemLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 18 Description Defines the user assigned location for this chassis Syntax DellString Access Read write Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 19 Description Defines the user assigned primary user name for this chassis Syntax DellString Access Read write 76 Chassis Information Group Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberNam Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 20 Description Defines the user assigned phone number of the primary user of the system Syntax DellString Access Read write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 21 Description Defines the status of the connection from the system chassis to an expansion chassis Syntax DellC onnectionStatus See Table 6 3 Access Read only Chassis Fan Control Capabili
498. s Read only Systems Management Software Language Name Name systemManagement SoftwareLanguageName Object ID 1 3 6 1 4 1 674 10892 1 100 9 Description Defines the language of the systems management software Syntax DisplayString SIZE 0 255 Access Read only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1 3 6 1 4 1 674 10892 1 100 10 Description Defines the global version of the systems management software Syntax DellString Access Read only Systems Management Software Feature Flags Name systemManagement SoftwareFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 100 11 Description Defines the features of the systems management software Syntax SM SFeatureF lags See Table 4 2 Access Read only Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 100 12 Description Defines the features of the SNM P agent software provided by the operating system 46 Systems M anagement Software Group Name systemManagementSoftwareSNMPAgentFeatureFlags Syntax SM SSN M PAgentFeatureF lags See Table 4 3 Access Read only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 100 13 Description Defines the manufacturer of the systems management software Syntax DellString Access Read only Systems Management Softw
499. s actual or imminent loss of data or loss of function such as crossing a failure threshold or a hardware failure Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator All of the traps documented in this section belong to the M IB enterprise identified by OID 1 3 6 1 4 1 674 10892 1 and are sent with all of the trap variables documented in the section Trap Variables on page 690 The trap variables are sent in the order in which they are listed The messages in the D escription fields below show the format of the message that is sent in the alertM essage varbind If a message in a Description field has multiple lines the message contains newline OAh characters that are part of the value in the alertM essage varbind 696 Traps Miscellaneous Traps Table 27 2 lists M iscellaneous traps that inform you that certain alert systems are up and working Table 27 2 Miscellaneous Traps TrapID Description Severity Cause System Up 1001 Server Administrator Information Server Administrator completed its startup complete initialization Thermal Shutdown 1004 Thermal shutdown Error protection has been initiated This message is generated when a system is configured for thermal shutdown due to an error event If a temperature sensor reading exceeds the error threshold for which the system is configured the operating system shuts down and
500. s for Dell OpenM anage Server Administrator Version 7 0 40 Dell OpenM anage Server Administrator Version 7 0 Instrumentation MIB Version Group The Instrumentation M anagement Information Base M IB Version Group defines the attributes that identify the version of the Instrumentation M IB supported by the systems management software The ml BM ajorVersionN umber ml BM inorVersionN umber and mIBM aintenanceVersionN umber attributes are scalar objects meaning that they are not related to other M IB objects and are thus not placed in a table Management Information Base Major Version Number Name mIBMajorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 1 0 Description Defines the major version number of the version of this M IB supported by the systems management software For example if the MIB version is 1 2 3 the major version number is 1 A major version number change indicates a major change in object functionality Syntax DellU nsigned8BitRange Access Read only Instrumentation MIB VersionGroup 41 Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 2 0 Description Defines the minor version number of the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the minor version number is 2 A minor revision provides additional support for new objects as well as problem fixes Syntax DellU nsigned8
501. s generated in response to events related to firmware driver upgrades downgrades K NOTE Currently there are no Update traps Audit Trap Group The Audit Trap Group contains traps that fall under the Audit event category of iD RAC7 Audit traps are traps generated in response to audit type events of iD RAC 7 such as authorizing of debugging changes to iD RAC 7 license state power state changes etc 766 iDRAC7 MIB Table 29 36 Debug Traps TrapID Description Category SubCategory Severity Debug Information 8595 Debug authorized Audit Debug Informational DebugWarning 8594 Debug authorization Audit Debug M inor failed Table 29 37 iDRAC IP Address Change Trap TrapID Description Category SubCategory Severity iDRAC IP Address Change 8499 iDRAC IP addresshas Audit DRAC IP Informational changed Address Table 29 38 License Traps TrapID Description Category SubCategory Severity License Information 8515 License information Audit Licensing Informational License Warning 8514 License warning Audit Licensing M inor License Failure 8513 License failure Audit Licensing Critical Table 29 39 System Power State Change Trap TrapID Description Category SubCategory Severity System Power State Change Information 8579 Hostisgoingthrougha Audit System Info Informational power state change powering on or powering off Configuration Trap Group The Configuration Trap Group contains traps that fall un
502. s hardware Syntax pAddress Access Read only 486 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name Object ID Description Syntax Access remoteAccessNICCurrent InfoFromDHCP 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware DellBoolean Read only Remote User Administration Table Name Object ID Description Syntax Access remoteUserAdminTable 1 3 6 1 4 1 674 10892 1 1700 20 Defines the Remote Access User Administration Table SEQUENCE OF RemoteUserAdminTableE ntry Not accessible Remote User Admin Table Entry Name Object ID Description Syntax Access Index remoteUserAdminTableEntry 1 3 6 1 4 1 674 10892 1 1700 20 1 Defines the Remote Access User Administration Table entry RemoteU serAdminTableE ntry Not accessible remoteU serAdminC hassisl ndex remoteU serAdminAdapterl ndex remoteU serAdminU serl ndex Remote Access Group 487 Remote User Admin Chassis Index Name remot eUserAdminChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellO bjectRange Access Read only Remote User Admin Adapter Index Name remot eUserAdminAdapter Index Object ID 1 3 6 1 4 1 674 10892 1 1700 20
503. s status is critical failure nonRecoverable 6 The object s status is nonrecoverable dead Table 30 6 Dell Status Redundancy Variable Name De11StatusRedundancy Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The object s redundancy status is unknown full 3 The object is fully redundant degraded 4 The object s redundancy has been degraded lost 5 The object s redundancy has been lost notRedundant 6 Redundancy does not apply or it is not redundant 792 Standard Data Type Definitions Table 30 7 Dell Status Probe Variable Name De11StatusProbe Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The status of the object is unknown ok 3 The status of the object is OK nonCriticalUpper 4 The object is at the noncritical upper limit CriticalUpper 5 The object is at the critical upper limit nonRecoverableUpper 6 The object is at the nonrecoverable upper limit nonCriticalLower 7 The object is at the noncritical lower limit criticalLower 8 The object is at the critical lower limit nonRecoverableLower 9 The object is at the nonrecoverable lower limit failed 10 The status of the object is failed Dell Date Variable Name De 1Date D
504. s unknown enabled 3 Device is enabled userDisabled 4 Device is disabled by the user biosDisabled 5 Device basic input output system BIOS is disabled Table 14 11 Cache Device ECC Type Variable Name De 1 1PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypeIsUnknown 2 Device type is unknown deviceTypelIsAMouse 3 Device type is a mouse deviceTypelIsATrackBall 4 Device type is a track ball deviceTypelIsATrackPoint 5 Device type is a track point deviceTypeIsAGlidePoint 6 Device type is a glide point deviceTypeIsATouchPad 7 Device type is a touch pad Table 14 12 Cache Device Associativity Variable Name De 1 1CacheDeviceAssociativity Data Type Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther 1 Device associativity is not one of the following 336 Device Group Table 14 12 Cache Device Associativity continued Variable Name De11CacheDeviceAssociativity Data Type Integer Possible Data Values Meaning of Data Value deviceAssociativityIsUnknown 2 Device associativity is unknown deviceAssociativityIsDirectMapped 3 Deviceis direct mapped deviceAssociativityIsTwoWaySetAsso Deviceis two way set ciative 4 associative deviceAssociativityIsFourWaySetAsso Deviceis fou
505. sModelName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 9 Description Defines the system model type for this chassis Syntax DellString Access Read only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 10 Description Defines the user assigned asset tag name for this chassis Syntax DisplayString SIZE 0 10 Access Read write Chassis Service Tag Name Name chassisServiceTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 11 Description Defines the service tag name for this chassis Syntax DisplayString SIZE 0 7 Access Read only 74 Chassis Information Group Chassis ID Name Object ID Description Syntax Access chassisID 1 3 6 1 4 1 674 10892 1 300 10 1 12 Defines the asset tag name for this chassis DellU nsigned8BitRange Read only Chassis ID Extension Name Object ID Description Syntax Access chassisIDExtension 1 3 6 1 4 1 674 10892 1 300 10 1 13 Defines the SM BIOS machine ID of this chassis DellUnsigned16BitRange Read only Chassis System Class Name Object ID Description Syntax Access chassisSystemClass 1 3 6 1 4 1 674 10892 1 300 10 1 14 Defines the chassis class of this chassis DellC hassisSystemC lass See Table 6 21 Read only Chassis System Name Name Object ID Description Syntax Access chassisSystemName 1 3 6 1 4 1 674 10892 1 300 10 1 15 Defines the system name of this chassis DellString Read only Chassi
506. sSystemClass Data Type Integer Possible Data Values Meaning of Data Value other 1 The chassis system class is not one of the following unknown 2 The chassis system class is unknown workstationClass 3 The chassis system class is a workstation serverClass 4 The chassis system class is a server desktopClass 5 The chassis system class is a desktop portableClass 6 The chassis system class is a portable netPCClass 7 The chassis system classis a Net PC storageClass 8 The chassis system class is storage Table 6 22 Firmware Type Variable Name De11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value other 1 The firmware type is other than following values unknown 2 T he firmware type is unknown systemBI0S 3 T he firmware type is System BIOS mbeddedSystemManagementContro ller 4 The firmware type is Embedded System M anagement Controller powerSupplyParallelingBoard 5 The firmware type is Power Supply Paralleling Board systemBackPlane 6 T he firmware type is System Primary Backplane powerVault2XXSKernel 7 T he firmware type is D ell PowerVault 2XXS Kernel powerVault2XXSApplication 8 T he firmware type is PowerVault 2XXS Application Chassis Information Group 119 120 Table 6 22 Firmware Type continued Variable N
507. sabled 2 Enabled Syntax Integer Access Read only 594 Storage Management Group Enclosure Backplane Part Number Name Object ID Description Syntax Access enclosureBackplanePartNumber 1 3 6 1 4 1 674 10893 1 20 130 3 1 21 Identifies the part number of the enclosure s backplane Integer Read only Enclosure SCSI ID Name Object ID Description Syntax Access enclosureSCSIID 1 3 6 1 4 1 674 10893 1 20 130 3 1 22 Identifies the SCSI ID of the controller to which this enclosure is attached Integer Read only Enclosure Roll Up Status Name Object ID Description Syntax Access enclosureRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 3 1 23 Identifies the severity of the enclosure state This is the combined status of the enclosure and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 595 Enclosure Component Status Name enclosureComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 24 Description T he status of the enclosure itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Enclosure Nexus ID Name enclosureNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 25 Description Durable unique ID for this enclosure Synta
508. sed M ost variables in this reference guide use standard data types such as string or boolean All data types that are unique to server administrator variables are defined at the end of the section in which they occur Standard data types are defined in Standard D ata Type Definitions on page 789 Access specifies whether persons with administrative privileges can read but not modify the value of a variable read only or can both read and modify the value of a variable read write Frequently Used Terms in Variable Names The following terms are frequently used in the name of a M IB variable C apability refers to the actions an object can perform or to actions that can be taken by the object H ot pluggable is an example of a capability If a card is hot pluggable it can be replaced while a system is running C apability settings refer to the capabilities of the object that the user can select from and activate if desired C apability settings allow users of the server administrator to predetermine how an object behaves under specific conditions Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component For example a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius If the probe reaches that temperature the setting causes an alert to be sent to the management console Some settings when reached can trigger a system shutdown or othe
509. sented in Storage Management to which this fan belongs Syntax DisplayString Access Read only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs Syntax Integer Access Read only Power Supply Table This table describes available properties for each power supply on the managed system The following object sets up the Power Supply Table Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 Description Defines the power supply table Syntax SEQUENCE OF PowerSupplyEntry Access Not accessible 626 Storage Management Group Power Supply Entry Name powerSupplyEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 Description Defines the power supply table entry Syntax PowerSupplyE ntry Access Not accessible Index powerSupplyN umber Power Supply Number Name powerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 1 Description Identifies the instance number of the power supply entry Syntax Integer Access Read only Power Supply Name Name powerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 2 Description Identifies the power supply s name as represented in Storage M anagement Syntax DisplayString Access Read only Power Supply Vendor Name powerSupplyVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 3 D
510. sis Information Group Name postLogTableEntry Access Not accessible Index postL ogchassisl ndex postL ogR ecord ndex POST Log Chassis Index Name postLogchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only POST Log Record Index Name post LogRecordIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 2 Description Defines the record number one based of the POST log Syntax DellU nsigned32BitRange Access Read only POST Log State Capabilities Unique Name postLogStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 3 Description Defines the capabilities of the object that is writing the POST log Syntax DellStateC apabilitiesL ogU nique Access Read only POST Log State Settings Unique Name postLogStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 4 Description Defines the state of the object that is writing the POST log Chassis Information Group 87 Name postLogStateSettingsUnique Syntax DellStateSettingsL ogU nique Access Read write POST Log Record Name postLogRecord Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 5 Description Defines the data for the specified chassis and record index in the POST log being returned Syntax DisplayString SIZE 0 1024 Access Read only POST Log Format Name postLogFormat Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 5 Description Defin
511. size in bytes of the free space on the array disk that is smaller than a megabyte T his size plus the arrayD iskF reeSpacel nM B is the total amount of free space on the array disk Syntax Integer Access Read only Array Disk Bus Type Name arrayDiskBusType Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 21 Description Identifies the bus type of the array disk Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 SSA 6 USB 7 SATA 8 SAS Syntax Integer Access Read only 606 Storage Management Group Array Disk Spare State Name Object ID Description Syntax Access arrayDiskSpareState 1 3 6 1 4 1 674 10893 1 20 130 4 1 22 Identifies the status of the array disk as a spare Possible states 1 Disk isa member of a virtual disk 2 Disk isa member of a disk group 3 Disk is a global hot spare 4 Disk is a dedicated hot spare 5 Not aspare 99 Not applicable Integer Read only Array Disk Roll Up Status Name Object ID Description Syntax Access arrayDiskRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 4 1 23 Severity of the array disk state This is the combined status of the array disk and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 607 Array Disk Component Status Name arrayDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 24 Description The status of the array
512. sktop 3 The chassis type is a desktop lowProfileDesktop 4 The chassis type is a low profile desktop pizzaBox 5 The chassis type is a pizza box miniTower 6 The chassis type is a minitower 108 Chassis Information Group Table 6 2 Chassis Type continued Variable Name Del 1ChassisType Data Type Integer Possible Data Values Meaning of Data Value tower 7 The chassis type is a tower portable 8 The chassis type is a portable lapTop 9 The chassis type is a laptop noteBook 10 The chassis type is a notebook handHeld 11 The chassis type is a handheld dockingStation 12 The chassis type is a docking station allInOne 13 The chassis type is an all in one subNoteBook 14 The chassis type is a subnotebook spaceSaving 15 The chassis type is a spacesaver lunchBox 16 The chassis type is a lunch box mainSystemChassis 17 The chassis type is the main system chassis expansionChassis 18 The chassis type is an expansion chassis subChassis 19 The chassis type is a subchassis busExpansionChassis 20 The chassis type is a bus expansion chassis peripheralChassis 21 The chassis type is a peripheral chassis raidChassis 22 The chassis type is a disk RAID chassis rackMountChassis 23 The chassis type is a rack mounted chassis sealedCasePC 24 The chassis type is a sealed
513. ss enclosureTotalSlots 1 3 6 1 4 1 674 10893 1 20 130 3 1 32 Shows the total number of physical slots in a storage enclosure it includes total count of occupied and empty slots NOTE A value of 9999 indicates that the feature is not available Integer Read only Enclosure Empty Slot Count Name Object ID Description Syntax Access enclosureEmptySlotCount 1 3 6 1 4 1 674 10893 1 20 130 3 1 33 Shows the number of empty physical disk slots in a storage enclosure NOTE A value of 9999 indicates that the feature is not available Integer Read only 598 Storage Management Group Array Disk Table This table describes available properties for each physical array disk on the managed system The following object sets up the Array Disk Table Name Object ID Description Syntax Access arrayDiskTable 1 3 6 1 4 1 674 10893 1 20 130 4 Defines the array disk table SEQUENCE OF ArrayD iskEntry Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 Description Defines the array disk table entry Syntax ArrayD iskE ntry Access Not accessible Index arrayD iskN umber Array Disk Number Name arrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 1 Description Identifies the instance number of the array disk entry Syntax Integer Access Read only Storage Management Group 599 Array Disk Name Name arrayDiskName Object ID 1 3 6 1 4 1 674 10893 1
514. ss memoryDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 1 Defines the index one based of this chassis DellO bjectRange Read only DeviceGroup 283 Memory Device Index Name Object ID Description Syntax Access memoryDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 2 Defines the index of the memory device in this chassis DellO bjectRange Read only Memory Device State Capabilities Name Object ID Description Syntax Access memoryDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 50 1 3 Defines the capabilities of the memory device DellStateC apabilities Read only Memory Device State Settings Name Object ID Description Syntax Access memoryDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 50 1 4 Defines the state of the memory device DellStateSettings Read write Memory Device Status Name Object ID Description Syntax Access memoryDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 50 1 5 Defines the status of the memory device DellStatus Read only 284 Device Group Memory Device Memory Port Index Reference Name memoryDeviceMemoryPort IndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 6 Description Defines the index of the memory port of which this memory device is part Syntax DellO bjectRange Access Read only Memory Device Type Name memoryDeviceTyp Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 7 Description Defines the type of the memory device
515. ss Read write COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 7 Description Defines the maintenance agreement restrictions Syntax DellC ostofO wnershipString Access Read write COO Repair Table Name cooRepairTable Object ID 1 3 6 1 4 1 674 10892 1 1600 90 Description Defines the COO Repair Table Syntax SEQUENCE OF CooRepairTableE ntry Access Not accessible 462 Cost of Ownership Group COO Repair Table Entry Name Object ID Description Syntax Access Index cooRepairTableEntry 1 3 6 1 4 1 674 10892 1 1600 90 1 Defines the COO Repair Table entry CooRepairTableE ntry Not accessible cooRepairchassislndex cooR epairl ndex COO Repair Chassis Index Name Object ID Description Syntax Access cooRepairchassisIndex 1 3 6 1 4 1 674 10892 1 1600 90 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Repair Index Name Object ID Description Syntax Access cooRepairIndex 1 3 6 1 4 1 674 10892 1 1600 90 1 2 Defines the index one based of the repair information for this system DellO bjectRange Read only COO Repair State Name Object ID Description Syntax Access cooRepairState 1 3 6 1 4 1 674 10892 1 1600 90 1 3 Defines the state of the repair information for this system DellStateSettings Read only CostofOwnership Group 463 COO Repair Counter Name Object ID Descripti
516. ssis DellString Read only Dell Remote Access Controller Out of BandGroup 693 DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 11 Description Defines the service tag of a system Syntax DellString Access Read only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 12 Description Defines the asset tag of a system Syntax DellString Access Read only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1 3 6 1 4 1 674 10892 2 1 1 13 Description Defines the slot number of a CMC Syntax DellString Access Read only DRsProductType Name DRsProductType Object ID 1 3 6 1 4 1 674 10892 2 1 1 14 Description Defines type of a remote access card Syntax DellRacType Access Read only 694 Dell Remote Access Controller Out of Band Group DRsFirmwareVersion Name Object ID Description Syntax Access DRsFirmwareVersion 1 3 6 1 4 1 674 10892 2 1 2 1 Defines the firmware version of a chassis management controller DellString Read only Chassis Status The following M IB tables provide information on Chassis being monitored by the chassis management card DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10892 2 2 1 Description Defines the overall chassis status being monitored by the chassis management card Syntax DellStatus Access Read only DRsGlobalCurrStatus Name DRsGlobalCurrStatus Obj
517. ssis management card Syntax DellStatus Access Read only DRsBladePrevStatus Name DRsBladePrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 7 Description Defines the previous blade subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only Dell Remote Access Controller Out of BandGroup 701 DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 8 Description Defines the temperature sensor health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 9 Description Definesthe CMC health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsGlobalChangeTime Name DRsGlobalChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 1 Description Defines the timestamp of the most recent global status change Syntax TimeTicks Access Read only DRslOMChangeTime Name DRsIOMChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 2 Description Defines the timestamp of the most recent IOM status change Syntax TimeTicks Access Read only 702 Dell Remote Access Controller Out of Band Group DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 3 Description Defines the timestamp of the most recent iKVM status change Syntax TimeTicks Access Read only DRsRedChangeTime Name DRsRedCh
518. ssor device status traps provide status and warning information for processor devices present in a system with a BM C that reports the status of processor devices Table 27 14 Processor Device Status Traps TrapID Description Severity Cause Processor Device Status Normal 1602 Processor sensor returned to a Information A processor sensor in the normal value specified system Sensor Location lt Location in transitioned back to a chasaes normal state T he sensor location chassis location Chassis Location lt N ame of previous state and processor chassis gt sensor status are provided Previous state was lt State gt Processor sensor status lt status gt Processor Device Status Warning 1603 Processor sensor detected a Warning A processor sensor in the warning value specified system isin a Sensor Location lt Location in throttled state T he sensor chassis gt location chassis location previous state and processor Chassis Location lt N ame of sensor status are provided chassis gt Previous state was lt State gt Processor sensor status lt status gt 716 Traps Table 27 14 Processor Device Status Traps continued TrapID Description Severity Cause Processor Device Status Failure 1604 Processor sensor detected afailure Error A processor sensor in the value specified system is disabled Sensor Location lt Location in has a configuration error or chassis gt experienced a the
519. st of Ownership Group COO Lease Information Index Name Object ID Description Syntax Access cooLeaseInformationIndex 1 3 6 1 4 1 674 10892 1 1600 50 1 2 Defines the index of the lease information for this system DellObjectRange Read only COO Lease Information State Name Object ID Description Syntax Access cooLeaseInformationState 1 3 6 1 4 1 674 10892 1 1600 50 1 3 Defines the lease information state for this system DellStateSettings Read write COO Lease Information Multiple Schedules Name Object ID Description Syntax Access cooLeaseInformationMultipleSchedules 1 3 6 1 4 1 674 10892 1 1600 50 1 4 Defines whether there are multiple schedules for this lease DellBoolean Read only COO Lease Information Buyout Amount Name Object ID Description Syntax Access cooLeaseInformationBuyOutAmount 1 3 6 1 4 1 674 10892 1 1600 50 1 5 Defines the balance purchase price for this system DellU nsigned32BitRange Read write Costof Ownership Group 455 COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 6 Description Defines the rate factor for the lease on this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 7 Description Defines the end date for the lease on this system Syntax DellD ateN
520. state settings for the object that is writing the event log Syntax DellStateSettingsL ogU nique Access Read write Event Log Record Name event LogRecord Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 5 Description Definesthe data for the specified chassis and log record index in the event log being returned Syntax DisplayString SIZE 0 1024 Access Read only Event Log Format Name event LogFormat Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 6 Description Defines the format of the event log Syntax D ellLogFormat See Table 6 1 Access Read only Event Log Severity Status Name eventLogSeverityStatus Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 7 Description Defines the severity of the event log record Syntax DellStatus Access Read only Status M andatory 90 Chassis Information Group Event Log Date Name Name event LogDateName Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 8 Description Defines the date and time of the event log record Syntax DellDateName Access Read only Status Mandatory System BIOS Table Thistable lists objects that define the system s basic input output system BIOS Name systemBIOSTable Object ID 1 3 6 1 4 1 674 10892 1 300 50 Description Defines the System BIOS Table Syntax SEQUENCE OF SystemBlOSTableEntry Access Not accessible System BIOS Table Entry Name systemBIOSTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 Description Defines the System BIOS Table entry Syntax S
521. stem SM BIOS and so on Chassis Information Group Tables The following management information base M IB tables define the objects in the Chassis Information Group e Chassis Information Table on page 71 e UUID Table on page 84 e POST Log Table on page 86 Event Log Table on page 88 System BIOS Table on page 91 Firmware Table on page 98 e Intrusion Table on page 101 Baseboard Table on page 103 Chassis Information Table The following object sets up the Chassis Information Table Name chassisInformationTable Object ID 1 3 6 1 4 1 674 10892 1 300 10 Description Defines the chassis information table Syntax SEQUENCE OF ChassisInformationTableE ntry Access Not accessible Chassis Information Group 71 Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 Description Defines the chassis information table entry Syntax Chassisl nformationTableE ntry Access Not accessible Index chassis ndexC hassisI nformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 1 Description Defines the index one based of this chassis The first chassis is numbered one Syntax DellO bjectRange Access Read only Chassis State Capabilities Name chassisStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 2 Description Defines the capabilities of the chassis Syntax DellS
522. strumentation and RAC traps Trap variables are sent in the order listed and are reserved for use only in traps W hen a varbind is created for a trap variable a zero is appended to the object ID OID to create the OID for the varbind System Variable Name Object ID Description Syntax Table Index OID Variable Name Object ID Description Syntax Message Variable Name Object ID Description Syntax Traps alertSystem 1 3 6 1 4 1 674 10892 1 5000 10 1 Identifies the system generating the alert DisplayString SIZE 0 255 alertTableIndexOID 1 3 6 1 4 1 674 10892 1 5000 10 2 Specifies the object identifier for the index attribute in the table that contains the object causing the alert Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object OBJECT IDENTIFIER alertMessage 1 3 6 1 4 1 674 10892 1 5000 10 3 Describes the alert DisplayString SIZE 0 1024 Current Status Variable Name Object ID Description Syntax Previous Status Variable Name Object ID Description Syntax Data Variable Name Object ID Description Syntax alertCurrentStatus 1 3 6 1 4 1 674 10892 1 5000 10 4 Specifies the current status of the object causing the alert DellStatus alertPreviousStatus 1 3 6 1 4 1 674 10892 1 5000 10 5 Specifies the previous status of the object causing the alert DellStatus alertData 1 3 6 1 4 1 674 10892 1 5
523. supported 53 Incompatible Integer Read only Storage Management Group 601 Array Disk Severity Name arrayDiskSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 5 Description This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Syntax Integer Access Read only Array Disk Product ID Name arrayDiskProductID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 6 Description Identifies the model number of the array disk Syntax DisplayString Access Read only Array Disk Serial Number Name arrayDiskSerialNo Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 7 Description Identifies the array disk s unique identification number from the manufacturer Syntax DisplayString Access Read only Array Disk Revision Name arrayDiskRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 8 Description Identifies the firmware version of the array disk Syntax DisplayString Access Read only 602 Storage Management Group Array Disk Enclosure ID Name Object ID Description Syntax Access arrayDiskEnclosureID 1 3 6 1 4 1 674 10893 1 20 130 4 1 9 Identifies the SC SI ID of the enclosure processor to which this array disk belongs DisplayString Read only Array Disk Channel Name Object ID Description Syntax Access arrayDiskChannel 1 3 6 1 4 1 674 10893 1 20 130 4 1 10 Identifies the bus to which this array disk is connected Integer Read
524. system power power state state change change to to power off powered off 722 Traps Table 27 19 Enterprise specific Traps continued TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1006 alertDrscPower The RAC Information Error RAC DRAC On has detected detected a I a system system power power state state change change to to power on powered on 1007 alertDrsc The RAC Critical Event RAC has DRAC Watchdog has detected detected the III Expired that the system system watchdog watchdog expired has expired normally indicating a indicating a system hang system hang 1008 alertDrscBatt TheRAC M inor Error RAC DRAC Low Battery detected its III charge is battery below 25 charge is indicating below 25 that the full battery may only be able to power the DRSC for 8 10 minutes 1009 alertDrscTemp TheRAC Information Status RAC DRAC Normal Temperature temperature III probe has probe reading returned toa returned to normal value normal Traps 723 Table 27 19 Enterprise specific Traps continued TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1010 alertDrscTemp The RAC M inor Status RAC DRAC Warning Temperature temperature IIl probe has probe reading detected a exceeded Warning warning value threshold 1011 alertDrscTemp The RAC Critical Error RAC DRAC Critical Temperature temperature Ill probe has probe reading detected a exceed
525. tained component status Possible values 1 Other 2 Unknown 3 0K 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 644 Storage Management Group Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 12 Description Durable unique ID for this EMM Syntax DisplayString Access Read only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 13 Description Identifies the revision number of the enclosure management module Syntax DisplayString Access Read only Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Enclosure M anagement M odule C onnection Table Name enclosureManagementModuleConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 Description Defines the enclosure memory module connection table Syntax SEQUENCE OF EnclosureM anagementM oduleC onnectionEntry Access Not accessible Storage Management Group 645 Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 Description Defines the enclosure me
526. tate of this system resource memory Syntax DellO bjectRange Access Read write System Resource Memory Status Name systemResourceMemoryStatus Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 5 Description Defines the status of this system resource memory Syntax DellStatus Access Read only 138 System Resource Group System Resource Memory Owner Index Reference Name Object ID Description Syntax Access systemResourceMemoryOwnerIndexReferenc 1 3 6 1 4 1 674 10892 1 500 40 1 6 Defines the index to the associated system resource owner in this chassis DellO bjectRange Read only System Resource Memory Share Disposition Name Object ID Description Syntax Access systemResourceMemoryShareDisposition 1 3 6 1 4 1 674 10892 1 500 40 1 7 Defines the share disposition of the system resource memory D ellResourceShareD isposition See Table 8 3 Read only System Resource Memory Starting Address Name Object ID Description Syntax Access systemResourceMemoryStartingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 8 Defines the 64 bits of the starting address of the system resource memory DellU nsigned64BitRange Read only System Resource Memory Ending Address Name Object ID Description Syntax Access systemResourceMemoryEndingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 9 Defines the 64 bits of the ending address of the system resource memory DellUnsigned64BitR ange Read only Sys
527. tateC apabilities Access Read only Chassis State Settings Name chassisStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 3 Description Defines the state settings for the chassis Syntax DellStateSettings Access Read write 72 Chassis Information Group Chassis Status Name Object ID Description Syntax Access chassisStatus 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the status of the chassis DellStatus Read only Chassis Parent Index Reference Name Object ID Description Syntax Access Chassis Type Name Object ID Description Syntax Access Chassis Name Name Object ID Description Syntax Access chassisparentIndexReferenc 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the index one based of the parent chassis of this chassis if any A zero 0 means that this chassis is the parent of all other chassis managed by the Server Administrator DellO bjectRange Read only chassisType 1 3 6 1 4 1 674 10892 1 300 10 1 6 Defines the chassis type DellC hassisT ype See Table 6 2 Read only chassisName 1 3 6 1 4 1 674 10892 1 300 10 1 7 Defines the user assigned chassis name of the chassis DellString Read write Chassis Information Group 73 Chassis Manufacturer Name Name chassisManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 8 Description Defines the manufacturer s name for this chassis Syntax DellString Access Read only Chassis Model Name Name chassi
528. tax DellSDC ardD eviceC onfigC apabilities Device Group 317 Name sdCardDeviceConfigCapabilities Access Read only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 6 Description Defines the configuration settings of the SD Card device Syntax DellSDC ardD eviceC onfigSettings Access Read only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 7 Description Defines the location of the SD Card device Syntax DellString Access Read only SD Card Device Card Present Name sdCardDeviceCardPresent Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 8 Description Defines whether the SD Card is present for the SD Card device Syntax DellBoolean Access Read only SD Card Device Card State Name sdCardDeviceCardState Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 9 Description Defines the state of the SD Card Syntax DellSDC ardD eviceC ardState 318 Device Group Name sdCardDeviceCardState Access Read only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 10 Description Defines the storage size in MB megabytes of the SD card for the SD Card device Syntax DellUnsigned32BitRange Access Read only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 11 Description Defines t
529. tax DellStatus Access Read only System State Chassis State Name systemStateChassisState Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 3 Description Defines the system state of this chassis Syntax DellStateSettings Access Read only System State Chassis Status Name systemStateChassisStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 4 Description Defines the system status of this chassis Syntax DellStatus Access Read only 52 System State Group System State Power Unit State Details Name Object ID Description Syntax Access systemStatePowerUnitStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 5 Defines the state of all power units in this chassis T he results are returned as a binary octet string Each byte of the octet string represents the state of a specific power unit The first byte returned represents the state of the first power unit the second byte returned represents the state of the second power unit and so on The bytes have the same definition type as D ellStateSettings Octet String Size 1 128 Read only System State Power Unit Status Redundancy Name Object ID Description Syntax Access systemStatePowerUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 6 Defines the system status of the power unit s in this chassis DellStatus Read only System State Power Unit Status Details Name Object ID Description Syntax Access systemStatePowerUnitStatusDetails 1 3 6 1 4 1 674
530. te systemSlotProvides5Volts 128 The system slot provides a 5 V supply systemSlotProvides3Point3Volts 256 The system slot provides a 3 3 V supply sys temSlotIsShared 512 The slot s opening is shared with another slot SlotGroup 355 Table 15 2 System Slot State Settings continued Variable Name De11SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value systemSlot Support sCardl16 1024 The system slot supports PC Card 16 systemSlot Support sCardBus 2048 The system slot supports CardBus systemSlotSupportsZoomVideo 4096 Thesystem slot supports zoom video systemSlot Support sModemRingResume The system slot supports modem 8192 ring resume systemSlot Support sPMESignal 16384 The system slot supports power management enable PM E signal support sPMEand3P 3Vand5VandHotPlugg The system slot supports power able 16770 management enable support sPMEand3P3Vand5VhasAdapteroO The system slot supports power n 16804 management event PME supplies 3 3 V and supplies 5 V The adapter is on support sPMEand3P3Vand5VhasAdapter Thesystem slot supports PME OnandisHotPluggable 16806 supplies 3 3 V and supplies 5 V The adapter is on and the system slot is hot pluggable support sPMEand3P3VIsSharedand5Vhas The system slot supports PME AdapterOnandisHotPluggable 17316 supplies 3 3 V supplies 5
531. te the value returned for this attribute is the discrete reading for the cooling device DellC oolingD eviceD iscreteReading See Table 10 3 Read only Temperature Probe Table Name Object ID Description Syntax Access temperatureProbeTabl 1 3 6 1 4 1 674 10892 1 700 20 Defines the Temperature Probe Table TemperatureProbeTableE ntry Not accessible Thermal Group 207 Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 Description Defines the Temperature Probe Table entry Syntax TemperatureProbeT ableE ntry Access Not accessible Index temperatureP robechassisl ndex temperatureProbel ndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Temperature Probe Index Name temperatureProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 2 Description Defines the index of temperature probes in this chassis Syntax DellO bjectRange Access Read only Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 3 Description Defines the capabilities of the temperature probe Syntax DellStateC apabilities Access Read only 208 Thermal Group Temperature Probe State Settings Name Object ID Description Syntax Acc
532. teAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read write 474 Remote Access Group Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read write Remote Access Personal Computer Memory Card International Association PCMCIA Info Name Name remot eAccessPCMCIAInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Description Defines the information for the PCMCIA device used by the remote access hardware Syntax DisplayString SIZE 0 63 Access Read only Remote Access Group 475 Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Description Defines the miscellaneous information for the remote access hardware Synta
533. teger Read only Storage Management Group 633 Temperature Probe Name Name temperatureProbeNam Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 2 Description Identifies the temperature probe s name as represented in Storage Management Syntax DisplayString Access Read only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 3 Description Identifies the temperature probe s re seller s name Syntax DisplayString Access Read only Temperature Probe State Name temperatureProbeStat Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 4 Description Identifies the current state of the temperature probe Possible states 0 Unknown 1 Ready 2 Failed Minimum Failure Threshold Exceeded M aximum Failure Threshold Exceeded 4 Offline 6 Degraded Minimum Warning Threshold Exceeded M aximum Warning Threshold Exceeded 9 Inactive 21 Missing Syntax Integer Access Read only 634 Storage Management Group Temperature Probe Severity Name Object ID Description Syntax Access temperatureProbeSeverity 1 3 6 1 4 1 674 10893 1 20 130 11 1 5 This entry is obsolete for Storage M anagement It was replaced with RollU pStatus and C omponentStatus for each device Integer Read only Temperature Probe Unit Name Object ID Description Syntax Access temperatureProbeUnit 1 3 6 1 4 1 674 10893 1 20 130 11 1 6 The units that are used to display
534. tem Resource Group 139 System Resource Memory Flags Name Object ID Description Syntax Access systemResourceMemoryFlags 1 3 6 1 4 1 674 10892 1 500 40 1 10 Defines the permission flags for the system resource memory DellResourceM emoryF lags See Table 8 4 Read only System Resource Interrupt Table Name Object ID Description Syntax Access systemResourceInterruptTable 1 3 6 1 4 1 674 10892 1 500 50 Defines the System Resource Interrupt Table SEQUENCE OF SystemResourcel nterruptTableE ntry Not accessible System Resource Interrupt Table Entry Name Object ID Description Syntax Access Index systemResourcelInterruptTableEntry 1 3 6 1 4 1 674 10892 1 500 50 1 Defines the System Resource Interrupt Table entry SystemResourcel nterruptT ableE ntry Not accessible systemR esourcel nterrupt chassis ndex systemR esourcel nterrupt ndex System Resource Interrupt Chassis Index Name Object ID Description Syntax Access systemResourcelInterruptchassisIndex 1 3 6 1 4 1 674 10892 1 500 50 1 1 Defines the index one based of this chassis DellO bjectRange Not accessible 140 System Resource Group System Resource Interrupt Index Name Object ID Description Syntax Access systemResourcelInterrupt Index 1 3 6 1 4 1 674 10892 1 500 50 1 2 Defines the index one based of this interrupt resource DellO bjectR ange Read only System Resource Interrupt State Capabilities
535. temperatures for the temperature probe DisplayString Read only Temperature Probe Minimum Warning Name Object ID Description Syntax Access temperatureProbeMinWarning 1 3 6 1 4 1 674 10893 1 20 130 11 1 7 Identifies the minimum temperature that forces the probe into a warning state Integer Read only Temperature Probe Minimum Critical Name Object ID Description Syntax Access temperatureProbeMinCritical 1 3 6 1 4 1 674 10893 1 20 130 11 1 8 Identifies the minimum temperature that forces the probe into an error state Integer Read only Storage Management Group 635 Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 9 Description Identifies the maximum temperature that forces the probe into a warning state Syntax Integer Access Read only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 10 Description Identifies the maximum temperature that forces the probe into an error state Syntax Integer Access Read only Temperature Probe Current Value Name temperatureProbeCurValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 11 Description Identifies the current temperature of this probe Syntax Integer Access Read only 636 Storage Management Group Temperature Probe Roll Up Status Name Object ID Description Syntax Access
536. that the speed is unknown Syntax DellUnsigned32BitRange Access Read only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 11 Description Defines whether the PCI device in this chassis has detected a fault Syntax DellBoolean Access Read only PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 82 Description Defines the PCI Device Configuration Table Syntax SEQUENCE OF PCID eviceC onfigurationSpaceTableE ntry Access Not accessible PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 82 1 Description Defines the PCI Device Configuration Table entry Syntax PCIDeviceC onfigurationSpaceT ableE ntry Access Not accessible Index pC 1D eviceC onfigurationSpacechassisl ndex pC ID eviceC onfigurationSpacel ndex 300 Device Group PCI Device Configuration Space Chassis Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpacechassisIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 1 Defines the index one based of this chassis DellObjectRange Read only PCI Device Configuration Space Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 2 Defines the index one based of the PCI device configuration in this chassis DellO bjectRange Read o
537. the MIB group number assigned to the M IB group The Server Administrator Instrumentation M IB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt M IB group number gt where lt MIB group number gt isthe MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 2 Instrumentation M IB Version Group defines version 1 numbers of the Instrumentation MIB 3 Systems M anagement Software Group definesinformation 100 about the systems management software and the supported systems management standards 4 System State Group defines status state and redundancy for 200 a system and its components 5 Chassis Information Group defines chassis types events and 300 indicators 6 Operating System Group defines variables for name version 400 service pack and other information about a system s operating system 7 System Resource Group defines variables for input output 500 ports memory interrupts and direct memory access 8 Power Group defines variables for power units power 600 supplies and their current and voltage probes 9 Thermal Group defines variables for temperature probes and 700 cooling devices Introduction 19 Table 1 2 Server Administrator Instrumentation MIB
538. the SD Card Device Table Syntax SEQUENCE OF SdCardD eviceTableE ntry Access Not accessible SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 Description Defines the SD Card Device Table Entry Syntax SdC ardD eviceTableE ntry Access Not accessible Index sdC ardD eviceC hassis ndex sdC ardD evicel ndex SD Card Device Chassis Index Name Object ID Description Syntax sdCardDeviceChassisIndex 1 3 6 1 4 1 674 10892 1 1100 112 1 1 Defines the index one based of the chassis that contains the SD Card device DellO bjectRange 316 Device Group Name sdCardDeviceChassisIndex Access Read only SD Card Device Index Name sdCardDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 2 Description Defines the index one based of the SD Card device Syntax DellO bjectRange Access Read only SD Card Device Status Name sdCardDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 3 Description Defines the status of the SD Card device Syntax DellStatus Access Read only SD Card Device Type Name sdCardDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 4 Description Defines the type of the SD Card device Syntax DellSDCardD eviceType Access Read only SD Card Device Config Capabilities Name sdCardDeviceConfigCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 5 Description Defines the configuration capabilities of the SD Card device Syn
539. the interrupt request IRQ level of the system resource interrupt Syntax DellUnsigned32BitRange Access Read only System Resource Interrupt Type Name systemResourcelInterruptType Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 9 Description Defines the interrupt type of the system resource interrupt Syntax D ellResourcel nterruptType See Table 8 5 Access Read only 142 System Resource Group System Resource Interrupt Trigger Name Object ID Description Syntax Access systemResourcelInterruptTrigger 1 3 6 1 4 1 674 10892 1 500 50 1 10 Defines the interrupt trigger of the system resource interrupt D ellResourcel nterruptTrigger See Table 8 6 Read only System Resource Direct Memory Access DMA Table Name Object ID Description Syntax Access systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 Defines the System Resource DMA Table SEQUENCE OF SystemResourceD M ATableE ntry Not accessible System Resource DMA Table Entry Name Object ID Description Syntax Access Index systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 1 Defines the System Resource D M A Table entry SystemResourceD M ATableE ntry Not accessible systemResourceD M Achassisl ndex systemR esourceD M Alndex System Resource DMA Chassis Index Name Object ID Description Syntax Access systemResourceDMAchassisIndex 1 3 6 1 4 1 674 10892 1 500 60 1 1 Defines the index one based of this chassis DellO bjectR an
540. the parallel port Syntax D ellU nsigned64BitR ange Access Read only PortGroup 247 Parallel Port IRO Level Name parallelPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 12 Description Defines the Interrupt Request L evel IRQ of the parallel port Syntax D ellU nsigned8BitR ange Access Read only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 13 Description Defines if direct memory access DM A is supported by the parallel port Syntax DellBoolean Access Read only Serial Port Table Name serialPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 80 Description Defines the Serial Port Table Syntax IntegerSerialPortTableE ntry Access Not accessible Serial Port Table Entry Name serialPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 Description Defines the Serial Port Table entry Syntax SerialPortTableE ntry Access Not accessible Index serialPortchassisIndex serialPortl ndex 248 Port Group Serial Port Chassis Index Name serialPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Serial Port Index Name serialPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 2 Description Defines the index of the serial ports in this chassis Syntax DellO bjectRange Access Read only Serial Port State Capabilities Name ser
541. the system Syntax DellC ostofO wnershipString Access Read only COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 11 Description Defines the cost center name of the system Syntax DellC ostofO wnershipString Access Read write 440 Cost of Ownership Group COO User Information User Name Name Object ID Description Syntax Access cooUseriInformationUserName 1 3 6 1 4 1 674 10892 1 1600 10 1 12 Defines the name of the user for this system DellC ostofO wnershipString Read write COO Extended Warranty Start Date Name Name Object ID Description Syntax Access cooExtendedWarrantyStartDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 13 Defines the extended warranty start date for this system DellD ateN ame Read write COO Extended Warranty End Date Name Name Object ID Description Syntax Access cooExtendedWarrantyEndDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 14 D efines the extended warranty end date for this system DellD ateN ame Read write COO Extended Warranty Cost Name Object ID Description Syntax Access cooExtendedWarrantyCost 1 3 6 1 4 1 674 10892 1 1600 10 1 15 Defines the extended warranty cost date for this system DellU nsigned32BitRange Read write Costof Ownership Group 441 COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1 3 6 1 4 1 674 10892 1 1
542. ties Unique Name chassisFanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 22 Description Defines the capabilities of the fan control function in this chassis Syntax DellFanC ontrolC apabilities See Table 6 4 Access Read only Chassis Fan Control Settings Unique Name chassisFanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 23 Description Defines the readings and settings of the fan control hardware in the chassis Syntax DellFanC ontrolSettings Access Read write Chassis Information Group 77 Chassis LED Control Capabilities Unique Name Object ID Description Syntax Access chassisLEDControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 24 Defines the capabilities of the LED control function in the chassis DellLED ControlC apabilities See Table 6 5 Read only Chassis LED Control Settings Unique Name Object ID Description Syntax Access chassisLEDControlSettingsUnique 1 3 6 1 4 1 674 10892 1 300 10 1 25 Defines the readings and settings of the LED control hardware in the chassis DellLEDC ontrolSettings See Table 6 6 Read write Chassis Hard Drive HD Fault Clear Control Capabilities Name Object ID Description Syntax Access chassisHDFaultClearControlCapabilities 1 3 6 1 4 1 674 10892 1 300 10 1 26 Specifies whether the chassis allows reset of the chassis hard drive fault LED DellH DFaultLEDC ontrolC apabilities See Table 6
543. tion Syntax DellO bjectRange Access Read only Costof Ownership Group 457 COO Schedule Number State Name cooScheduleNumberStat Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 3 Description Defines the schedule number information state of this system Syntax DellStateSettings Access Read only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 4 Description Defines the lease information index number to reference the schedule number Syntax D ellU nsigned32BitR ange Access Read write COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 5 Description D escribes the schedule number information Syntax DellC ostofO wnershipString Access Read write COO Options Table Name cooOptionsTable Object ID 1 3 6 1 4 1 674 10892 1 1600 70 Description D efinesthe COO Options Table Syntax SEQUENCE OF CooOptionsTableE ntry Access Not accessible 458 Cost of Ownership Group COO Options Table Entry Name Object ID Description Syntax Access Index cooOptionsTableEntry 1 3 6 1 4 1 674 10892 1 1600 70 1 Defines the COO Options Table entry CooO ptionsTableE ntry Not accessible cooO ptionschassisl ndex cooO ptions ndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 1 Description Defin
544. tion chassis location previousstate and current sensor value are provided Traps 705 Table 27 6 Amperage Probe Traps continued TrapID Description Severity Cause Amperage Probe Failure 1204 Current sensor detected a failure value Error Sensor location lt L ocation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete C urrent sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt A current sensor on the power supply for the specified system exceeded its failure threshold T he sensor location chassis location previousstate and current sensor value are provided Amperage Probe Non recoverable 1205 Current sensor detected a Error non recoverable value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete C urrent sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt A current sensor in the specified system detected an error from which it cannot recover The sensor location chassis location previous state and current sensor value are provided 706 Traps Chassis Intrusion Traps Chassis intrusion traps are a security measure C hassis intrusion means that someone is opening the cover to a system s
545. try Not accessible arrayD iskL ogicalC onnectionN umber Array Disk Logical Connection Number Name Object ID Description Syntax Access arrayDiskLogicalConnectionNumber 1 3 6 1 4 1 674 10893 1 20 140 3 1 1 Identifies the instance number of the disk entry Integer Read only Array Disk Logical Connection Array Disk Name Name Object ID Description Syntax Access arrayDiskLogicalConnectionArrayDiskName 1 3 6 1 4 1 674 10893 1 20 140 3 1 2 Identifies the name of the array disk in this logical connection DisplayString Read only Storage Management Group 667 Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 3 Description Identifies the instance number of the array disk in this logical connection Syntax Integer Access Read only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 4 Description Identifies the name of the virtual disk to which this array disk belongs Syntax DisplayString Access Read only Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 5 Description Identifies the instance number of the virtual disk to which this array disk belongs Syntax Integer Access Read only Array Disk Logical Connection Disk Name Nam
546. tting 1 3 6 1 4 1 674 10892 1 600 60 1 18 Defines the system power cap setting DellPowerC apSetting Read only Power Usage Power Cap Value Name Object ID Description Syntax Access powerUsagePowerCapValue 1 3 6 1 4 1 674 10892 1 600 60 1 19 Defines the system power cap value in Watts DellU nsigned32BitRange Read only 181 Power Group Power Usage Instantaneous Headroom Name Object ID Description Syntax Access powerUsagelInstantaneousHeadroom 1 3 6 1 4 1 674 10892 1 600 60 1 20 Defines the system instantaneous headroom in Watts Thisis the theoretical maximum power drawn by the power supply minus instantaneous power draw DellU nsigned32BitRange Read only Power Usage Peak Headroom Name Object ID Description Syntax Access powerUsagePeakHeadroom 1 3 6 1 4 1 674 10892 1 600 60 1 21 Defines the system peak headroom in Watts This is the theoretical maximum power drawn by the power supply minus peak power draw DellU nsigned32BitRange Read only Power Profile Table Name Object ID Description Syntax Access powerProfileTable 1 3 6 1 4 1 674 10892 1 600 70 Defines the Power Profile Table SEQUENCE OF PowerProfileTableEntry Not accessible Power Profile Table Entry Name Object ID Description Syntax powerProfileTableEntry 1 3 6 1 4 1 674 10892 1 600 70 1 Defines the Power Profile Table Entry PowerProfileTableE ntry 182 Power Group Name powerProf
547. ue maxPerformance 1 Power profile type is M aximum Performance osControl 2 Power profile type is OS control activePowerController 4 Power profile type is Active Power C ontroller custom 8 Power profile type is Custom Table 9 19 CPU Power Performance Management Type Variable Name De 1 1 CPUPowerPerformanceManagementTyp Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 CPU power and performance management type is M aximum Performance minPower 2 CPU power and performance management type is Minimum Power osDBPM 4 CPU power and performance management type is OS Demand Based Power M anagement systemDBPM 8 CPU power and performance management type is System D emand Based Power M anagement 196 Power Group Table 9 20 Memory Power Performance Management Type Variable Name De 1 1MemoryPowerPerformanceManagementTyp Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 M emory power and performance management type is Maximum Performance mhz1333 2 M emory power and performance is 1333 MHz mhz1067 4 M emory power and performance is 1067 M Hz mhz800 8 M emory power and performance is 800 M Hz minPower 16 M emory power and performance ma
548. ue Warning Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt A voltage sensor in the specified system exceeded its warning threshold T he sensor location chassis location previous state and voltage sensor value are provided Traps 703 Table 27 5 Voltage Probe Traps continued TrapID Description Severity Cause Voltage Probe Failure 1154 Voltage sensor detected a failure value Error Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt A voltage sensor in the specified system exceeded its failure threshold T he sensor location chassis location previous state and voltage sensor value are provided Voltage Probe Non recoverable 1155 Voltage sensor detected a Error non recoverable value Sensor location lt L ocation in chassis gt Chassis location lt N ame of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt A voltage sensor in the s
549. ues Meaning of Data Value none 0 The admin user has no state settings unknown 1 The admin user state settings are unknown enabled 2 The admin user is enabled not Ready 4 The admin user isin the not ready state numericPagerEnabled 8s Numeric paging is enabled for the admin user alphaPagerEnabled 16 Alphanumeric paging is enabled for the admin user emailEnabled 32 E mail is enabled for the admin user Table 20 14 Remote User Admin Control Capabilities Variable Name De 1 1RemoteUserAdminControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control capabilities unknownCapabilities 1 The admin user control capabilities are unknown numericPagerTestCapable 2 Theadmin user can support sending a test numeric page alphaPagerTestCapable 4 The admin user can support sending a test alphanumeric page emailTestCapable 8 The admin user can support sending a test email Remote Access Group 517 Table 20 15 Remote User Admin Control Settings Variable Name De 1 1RemoteUserAdminControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control settings unknown 1 The admin user control settings are unknown numericPagerTest 2 Anumeric pager test is performed for the admin user alphaPagerTest 4 An alphanumeric pager test
550. ues Meaning of Data Value other 1 Device type is other unknown 2 Device type is unknown hypervisor 3 Device type is H ypervisor vFlash 4 Device type is Virtual F lash vF lash Table 14 27 SD Card Device Config Capabilities Variable Name DellSDCardDeviceConfigCapabilities Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 SD card device has none of the following capabilities sdCapable 1 SD media can be enabled vF lashCapable 2 Virtual Flash vF lash can be enabled 346 Device Group Table 14 28 SD Card Device Config Settings Variable Name DellSDCardDeviceConfigSettings Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 SD card device has none of the following settings sdEnabled 1 SD media is enabled vF lashEnabled 2 Virtual Flash vF lash is enabled Table 14 29 SD Card Device Card State Variable Name DellSDCardDeviceCardState Data Type Integer Possible Data Values Meaning of Data Value none 0 SD card state is none of the following states present 1 Device is present ipmiReady 2 DeviceisIPM ready fullReady 4 Device is full ready offline 8 Device is offline failed 16 Device is failed active 32 Device is active bootable 64 Device is bootable
551. up variable names Cooling Device Table 201 capability 28 Cooling Unit Table 199 settings 28 Temperature Probe Table 207 state 28 variable values 213 status 28 trap variables 710 Viewing current status 711 SNMP traps 757 data 711 message 710 previous status 711 system 710 table index OID 710 traps 716 AC power cord traps 734 amperage probe traps 725 chassis intrusion traps 727 cooling device traps 721 fan enclosure traps 732 hardware log traps 735 memory device traps 731 miscellaneous traps 717 power supply traps 730 redundancy unit traps 728 temperature probe traps 719 understanding the trap descriptions 711 understanding trap severity 716 voltage probe traps 723 U User Security Table 217 221 Index 805 806 Index
552. upplyTypeIsConverter 7 The power supply type is a power converter power supply powerSupplyTypeIsRegulator 8 The power supply type is a regulator power supply powerSupplyTypelIsACc 9 The power supply type is an AC power supply Power Group 187 Table 9 3 Power Supply Type Definitions continued Data Type Integer Variable Name De 1 1PowerSupplyType Possible Data Values Meaning of Data Value powerSupplyTypelIsDC 10 The power supply typeisaDC power supply powerSupplyTypeIsVRM 11 The power supply type is a voltage regulator module VRM power supply Table 9 4 Power Supply Sensor State Data Type Integer Variable Name De 1 1PowerSupplySensorState Possible Data Values Meaning of Data Value presenceDetected 1 The power supply s presence is detected psFailureDetected 2 The power supply failure is detected predictiveFailure 4 The power supply sensor detects predictive failure psACLost 8 The power supply s AC power is lost acLostOrOutOfRange 16 The power supply s AC power is lost or out of range acOutOfRangeButPresent 32 The power supply s AC power is present but it is out of range configurationError 64 The power supply sensor detects a configuration error 188 Power Group Table 9 5 Power Supply Configuration Error Type Variable Name De 1 1PowerSup
553. ure Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax Access temperatureProbeUpperNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 9 Defines the value of the temperature probe s upper nonrecoverable threshold DellSigned32BitRange Read only Temperature Probe Upper Critical Threshold Name Object ID Description Syntax Access 210 temperatureProbeUpperCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 10 Defines the value of the temperature probe s upper critical threshold DellSigned32BitRange Read only Thermal Group Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 11 Description Defines the user assigned value of the temperature probe s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 12 Description Defines the user assigned value of the temperature probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 13 Description Defines the value of the temperature probe s lower critical threshold Syntax DellSigned32BitRange Access Read only
554. ut time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Dial Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 11 Description Defines the dial type for the modem used by this remote access dial up functionality Syntax DellRemoteDialU pM odemDialType See Table 20 24 Access Read write Remote Dial Up Modem Init String Name Name remoteDialUpModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 12 Description Defines the initialization string to be sent to the modem for this remote access dial up functionality Syntax DisplayString SIZE 0 63 Access Read write Remote Dial Up Modem Baud Rate Name remoteDialUpModemBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 13 Description Defines the baud rate for the modem used by this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Access Group 503 Remote Dial Up Modem Port Name Object ID Description Syntax Access remoteDialUpModemPort 1 3 6 1 4 1 674 10892 1 1700 40 1 14 Defines the port for the modem used by this remote access dial up functionality DellU nsigned32BitRange Read write Remote User Dial In Configuration Table Name Object ID Description Syntax Access remoteUserDialInCfgTable 1 3 6 1 4 1 674 10892 1 1700 50 Defines the Remote Access U ser Dial In Co
555. ute defines the fully qualified domain name of the system Syntax StringType Access Read only System Service Tag Name systemServiceTag Object ID 1 3 6 1 4 1 674 10892 5 1 3 2 0 Description This attribute defines the service tag of the system Syntax StringType Access Read only System Express Service Code Name systemExpressServiceCod Object ID 1 3 6 1 4 1 674 10892 5 1 3 3 0 Description This attribute defines the express service code of the system Syntax StringType Access Read only System Asset Tag Name systemAssetTag Object ID 1 3 6 1 4 1 674 10892 5 1 3 4 0 Description This attribute defines the asset tag of the system Syntax StringType Access Read only iDRAC7MIB 78 System Blade Slot Number Name systemBladeSlotNumber Object ID 1 3 6 1 4 1 674 10892 5 1 3 5 0 Description This attribute defines the slot number of the blade in the chassis Syntax StringType Access Read only System Operating System Name Name systemOSName Object ID 1 3 6 1 4 1 674 10892 5 1 3 6 0 Description This attribute defines the name of the operating system that the host is running Syntax StringType Access Read only System Form Factor Name systemFormFactor Object ID 1 3 6 1 4 1 674 10892 5 1 3 7 0 Description This attribute defines the form factor of the system Syntax SystemF ormF actorE num Access Read only System Data Center Name Name systemDataCenterNam Object ID 1 3 6 1 4 1 674 10892 5 1 3 8 0 D
556. variant known as GetN ext 34 Introduction SNMP Management Information Base Object Identifiers Each data class within a Management Information Base M IB is defined by an Object Identifier OID OID s are unique across all MIBs An OID consists of a series of digits separated by periods The OID functionsin a similar fashion to a phone number The phone number 011 512 471 0000 uniquely identifies a single phone T he phone number can be broken down into anumber of components to uniquely identify a phone The first component 011 is the country code for the United States The second component 512 identifies the area code for central Texas T he third component 471 is the phone exchange for a large state university in the city of Austin The final component 0000 is the main switchboard There are two main differences between the phone number example and an actual OID The first difference is that there are many more components in an OID up to 128 The combination of these components is called an OID prefix The second difference is that OID s support the concept of indexes or keys The OID prefix specifies the data class but does not specify an instance of the data within the class Indexes can be used to identify the instances of a data Class T hese indexes are referred to asthe OID suffix The assignment of values for each OID prefix component can be illustrated by using a tree structure The following is an example of an OID assign
557. ve the system that has a failing component send a broadcast message to the management system and power off the troubled system LRA Group Tables The following management information base M IB tables define LRA variable attributes LRA Global Settings Table on page 430 LRA Action Table on page 432 LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator Some machines may support all or some of the capabilities described in DellLocalResponseA gentC apabilitiesU nique The LRA Global Settings Table also defines thermal shutdown capabilities and settings In the event that a temperature probe determines the temperature is at or over the failure limit the systems manager can set an action to be taken automatically LocalResponseAgentGroup 429 LRA Global Settings Table Name 1LRAGlobalSettingsTable Object ID 1 3 6 1 4 1 674 10892 1 1500 10 Description Defines the LRA Global Settings Table Syntax SEQUENCE OF LRAG lobalSettingsTableE ntry Access Not accessible LRA Global Settings Table Entry Name 1LRAGlobalSettingsTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 Description Defines the LRA Global Settings Table entry Syntax LRAG lobalSettingsTableE ntry Access Not accessible Index IRAG lobalchassis ndex LRA Global Chassis Index Name 1RAGlobalchassisIndex Object ID 1 3 6 1 4 1 674 1
558. vice Tag Variable Name alertSystemServiceTag Object ID 1 3 6 1 4 1 674 10892 5 3 1 4 0 Description Service tag of the system Syntax DisplayString SIZE 0 16 Alert System FODN Variable Name alertSystemFQDN Object ID 1 3 6 1 4 1 674 10892 5 3 1 5 0 Description Fully qualified domain name of the system Syntax StringType 748 iDRAC7 MIB Alert FODD Variable Name alertFQDD Object ID 1 3 6 1 4 1 674 10892 5 3 1 5 0 Description Fully qualified device descriptor of the device Syntax DisplayString SIZE 0 512 System Trap Group The System Trap Group contains traps that fall under the System H ealth event category of the iD RAC 7 System H ealth traps are traps those are generally generated in response to events related to the hardware of the system in which an iD RAC 7 resides Amperage Probe Traps iDRAC7MIB 749 Table 29 1 Amperage Probe Traps TrapID Description Category SubCategory Severity Amperage Probe Normal 2179 Current sensor readingis System Amperage Informational within range Health Amperage Probe Warning 2178 Current sensor has System Amperage Minor detected a warning value Health Amperage Probe Failure 2177 Current sensor has System Amperage Critical detected a failure value Health Table 29 2 Automatic System Recovery Trap TrapID Description Category SubCategory Severity Automatic System Recovery 2233 Automatic system System Auto Sys Critical recovery ASR
559. viceFamilyIsPowerPC603Plus_ The processor family is Power PC 35 603 deviceFamilyIsPowerPC604 36 The processor family is Power PC 604 deviceFamilyIsPowerPC620 37 The processor family is Power PC 620 deviceFamilyIsPowerPCx704 38 The processor family is Power PC x704 deviceFamilyIsPowerPC750 39 The processor family is Power PC 750 deviceFamilyIsIntelCoreDuo 40 The processor family is Intel C ore Duo deviceFamilyIsIntelCoreDuoMobi The processor family is Intel C ore Duo le 41 mobile deviceFamilyIsIntelCoreSoloMob The processor family is Intel C ore Solo ile 42 mobile deviceFamilyIsIntelAtom 43 The processor family is Intel Atom deviceFamilyIsAlpha 48 The processor family is Alpha deviceFamilyIsAlpha21064 49 The processor family is Alpha 21064 deviceFamilyIsAlpha21066 50 The processor family is Alpha 21066 deviceFamilyIsAlpha21164 51 The processor family is Alpha 21164 deviceFamilyIsAlpha21164PC 52 The processor family is Alpha 21164PC deviceFamilyIsAlpha21164a 53 The processor family is Alpha 21164a deviceFamilyIsAlpha21264 54 The processor family is Alpha 21264 deviceFamilyIsAlpha21364 55 The processor family is Alpha 21364 326 Device Group Table 14 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value
560. viceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 Description Defines the Keyboard D evice Table T his table references the Keyboard Port Index See Section 12 Syntax SEQUENCE OF KeyboardD eviceTableE ntry Access Not accessible Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 Description Defines the Keyboard D evice Table entry Syntax KeyboardD eviceTableE ntry Access Not accessible Index keyboardD evicechassis ndex keyboardD evicel ndex 264 Device Group Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 1 Description Defines the index one based of this chassis Syntax DellO bjectRange Access Read only Keyboard Device Index Name keyboardDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 2 Description Defines the index of the keyboard device for this chassis Syntax DellO bjectRange Access Read only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 3 Description Defines the capabilities of the keyboard device Syntax DellStateC apabilities Access Read only Keyboard Device State Settings Name keyboardDeviceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 4 Description Defines the state of the keyboard device Syntax DellStatesSettings Access Read write DeviceGroup 265 Keyboard Device Status
561. was Health Reset performed Table 29 3 Battery Traps TrapID Description Category SubCategory Severity Battery Normal 2227 Battery state has System Battery Event Informational returned to normal or Health battery presence had been detected Battery Warning 2226 Battery is low System Battery Event Minor Health Battery Failure 2225 Battery has failed or System Battery Event Critical battery is absent Health 750 iDRAC7 MIB Table 29 4 Processor Device Status Traps TrapID Description Category SubCategory Severity Processor DeviceStatus Normal 2243 Processor device status has returned to normal ProcessorDeviceStatusWarning 2242 Processor device status has detected a warning ProcessorDeviceStatusFailure 2241 Processor device status has detected a failure System Health System Health System Health Processor Processor Processor Informational Minor Critical Table 29 5 Processor Device Absent Trap TrapID Description Category SubCategory Severity Processor Device Absent 2457 Processor device is System Proc Absent Critical absent Health iDRAC7MIB 751 Table 29 6 Fan Traps TrapID Description Category SubCategory Severity Fan Information 2155 Fan information System Fan Event Informational Health Fan Warning 2154 Fan warning System Fan Event M inor Health Fan Failure 2153 Fan failure System Fan Event Critical Health Table 29
562. werUsagePeakWatts 1 3 6 1 4 1 674 10892 1 600 60 1 9 178 l Power Group Description Syntax Access powerUsagePeakWatts Defines the peak wattage reading in Watts for this entity since the date and time specified by the powerU sagePeakW attsStartD ateN ame attribute DellU nsigned32BitRange Read only Power Usage Peak Watts Start Date Name Name Object ID Description Syntax Access powerUsagePeakWattsStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 10 Defines the date and time at which the data collection started for the value reported by the powerU sagePeakW atts attribute DellDateName Read only Power Usage Peak Watts Reading Date Name Name Object ID Description Syntax Access powerUsagePeakWattsReadingDateName 1 3 6 1 4 1 674 10892 1 600 60 1 11 Defines the date and time at which the value reported by the powerU sagePeakW atts attribute was measured DellDateName Read only Power Usage Peak Amps Name Object ID Description Syntax Access powerUsagePeakAmps 1 3 6 1 4 1 674 10892 1 600 60 1 12 Defines the peak amperage reading in tenths of Amps for this entity since the date and time specified by the powerU sagePeakA mpsStartD ateN ame attribute DellU nsigned32BitRange Read only 179 Power Group Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 13 Description Defines the date and time at which
563. with discrete reading Table 10 5 Temperature Probe Discrete Reading Variable Name De1 1 TemperatureDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value temperatureIsGood 1 The temperature probe discrete reading is good temperaturelIsBad 2 The temperature probe discrete reading is bad ThermalGroup 215 216 Thermal Group User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems User Security Group Table The User Security Group defines objects in the U ser Security M IB table User Security Table The following object sets up the User Security Table Name userSecurityTable Object ID 1 3 6 1 4 1 674 10892 1 800 Description Contains the database of users that are authorized to perform Set operations on a managed system Syntax UserSecurityTableE ntry Access Not accessible User Security Table Entry Name userSecurityTableEntry Object ID 1 3 6 1 4 1 674 10892 1 800 1 Description Defines a row in the User Security Table Syntax UserSecurityTableE ntry Access Not accessible Index userSecuritychassisl ndex userSecurityl ndex UserSecurityGroup 217 User Security Chassis Index Name userSecuritychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 1 Description Defines the user security index one based of this chassi
564. write 398 BIOS Setup Control Group BIOS Setup Control User Password New Password Name Name Object ID Description Syntax Access bSUCuserPasswordNewPasswordName 1 3 6 1 4 1 674 10892 1 1400 10 1 35 Defines the setup BIOS name of the new user password To set a new user password a you must have successfully set the current user password immediately preceding this password change DellString Read write BIOS Setup Control TPM Security Control Capabilities Name Object ID Description Syntax Access bSUCtpmSecurityControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 10 1 36 Defines the BIOS setup control capabilities of Trusted Platform M odule TPM security DellT PM SecurityC ontrolC apabilities Read only BIOS Setup Control TPM Security Control Setting Name Object ID Description Syntax Access bSUCtpmSecurityControlSetting 1 3 6 1 4 1 674 10892 1 1400 10 1 37 Defines the BIOS setup control setting of Trusted Platform M odule TPM security DellT PM SecurityC ontrolSetting Read only BIOS Setup Control TPM Security Control Status Name Object ID Description Syntax Access bSUCtpmSecurityControlStatus 1 3 6 1 4 1 674 10892 1 1400 10 1 38 Defines the BIOS setup control status of Trusted Platform M odule TPM security DellStatus Read only 399 BIOS Setup Control Group BIOS Setup Control TPM Security Control Name Name bSUCtpmSecurityControlName Object ID 1 3 6
565. x DisplayString SIZE 0 63 Access Read write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware Syntax pAddress Access Read only 476 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name remoteAccessNICCurrent InfoFromDHCP Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware Syntax DellBoolean Access Read only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 34 Description Def
566. x Integer Access Read only Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 26 Description T he firmware version of the enclosure Syntax DisplayString Access Read only 596 Storage Management Group Enclosure SCSI Rate Name Object ID Description Syntax Access enclosureSCSIRate 1 3 6 1 4 1 674 10893 1 20 130 3 1 27 Actual SCSI rate in the enclosure DisplayString Read only Enclosure Part Number Name Object ID Description Syntax Access enclosurePartNumber 1 3 6 1 4 1 674 10893 1 20 130 3 1 28 The part number of the enclosure DisplayString Read only Enclosure Serial Number Name enclosureSerialNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 29 Description Serial number of the enclosure Syntax DisplayString Access Read only Enclosure SAS Address Name enclosureSASAddress Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 30 Description T he specified SAS address if this is a SAS enclosure Syntax DisplayString Access Read only Storage Management Group 597 Enclosure Occupied Slot Count Name Object ID Description Syntax Access enclosureOccupiedsSlotCount 1 3 6 1 4 1 674 10893 1 20 130 3 1 31 Shows the number of physical disk slots occupied in a storage enclosure NOTE A value of 9999 indicates that the feature is not available Integer Read only Enclosure Total Slots Name Object ID Description Syntax Acce
567. yntax Integer Access Read only Battery Nexus ID Name Object ID Description Syntax Access batteryNexusID 1 3 6 1 4 1 674 10893 1 20 130 15 1 9 Durable unique D for thisEMM DisplayString Read only Storage Management Group 651 Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 10 Description Displays the battery s ability to be charged Possible values 1 Failed The battery cannot be charged and needs to be replaced 2 Ready The battery can be charged to full capacity 4 Unknown T he battery is completing a Learn cycle The charge capacity of the battery cannot be determined until the Learn cycle is complete Syntax Integer Access Read only Battery Next Learn Time Name batteryNextLearnTim Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 11 Description Indicates the time in hours the next learn cycle must be executed Syntax Integer Access Read only 652 Storage Management Group Battery Learn State Name batteryLearnState Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 12 Description Specifies the learn state activity of the battery Possible values 1 Failed 2 Active 4 Timed out 8 Requested 16 Idle Syntax Integer Access Read only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 14 Description The maximum amount of time in hours that the battery learn cycle can be del
568. ype Integer Possible Data Values Meaning of Data Value unknown 1 The remote flash BIOS s capabilities are unknown enableCapable 2 The remote flash BIOS can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The remote flash BIOS can be set to indicate not ready cancelCapable 8 Flash of BIOS can be canceled enableAndCancelCapable 10 _ Flash of BIOS can be enabled or canceled Table 12 2 Remote Flash BIOS State Settings Variable Name De 1 1RemoteFlashBIOSStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The remote flash BIOS s capabilities are unknown enabled 2 The remote flash BIO S update is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The remote flash BIO S s state is not ready canceled 8 The remote flash BIOS has been canceled pending 16 The remote flash BIOS update is pending other 32 The remote flash BIOS state setting is not one of the previous values 224 Remote Flash BIOS Group Table 12 3 Remote Flash BIOS Completion Code Variable Name De 1 1RemoteFlashBIOSCompletionCode Data Type Integer Possible Data Values Meaning of Data Value complet ionCodeIsOther 1 The completion code status is not one of the following complet ionCodeIsUnknown 2 The
569. ystemBIO STableE ntry Access Not accessible Index systemBI O SchassisI ndex systemBI O SI ndex System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Chassis Information Group 91 Name systemBlOSchassisIndex Access Read only System BIOS Index Name systemB1I0SIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 2 Description Defines the index one based of the system BIOS of this object Syntax DellObjectRange Access Read only System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 3 Description Defines the capabilities of the system BIOS of this object Syntax D ellStateC apabilities Access Read only System BIOS State Settings Name systemB1IOSStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 4 Description Defines the state of the system BIOS of this object Syntax DellStateSettings Access Read write System BIOS Status Name systemBlOSStatus Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 5 Description Defines the status of the system BIOS of this object Syntax DellStatus 92 Chassis Information Group Name systemBIOSStatus Access Read only System BIOS Size Name systemBIOSSize Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 6 Description Defines the image size of the system BIOS in kilobytes KB A zero 0 indicates t

Download Pdf Manuals