Home

Dell Computer Drive CMC 3.2 User's Manual

image

Contents

1. 189 cfgRacTuneConRedirPort Read Write 189 cfgRacTuneRemoteRacadmEnable Read Write 190 cfgRacTuneCtrlEConfigDisable 190 cfgRacTuneHttpPort Read Write 190 cfgRacTuneHttpsPort Read Write 191 cfgRacTunelpRangeEnable Read Write 191 cfgRacTunelpRangeAddr Read Write 191 cfgRacTunelpRangeMask Read Write 192 cfgRacTunelpBlkEnable Read Write 192 cfgRacTunelpBlkFailCount Read Write 192 cfgRacTunelpBlkFailWindow Read Write 193 cfgRacTunelpBlkPenaltyTime Read Write 193 cfgRacTuneSshPort Read Write 193 cfgRacTuneTelnetPort Read Write 193 cfgRacTuneConRedirEnable Read Write 194 cfgRacTuneConRedirEncryptEnable Read Write 194 cfgRacTuneAsrEnable Read Write 194 cfgRacTuneDaylightOffset Read Only 194 cfgRacTuneTimezoneOffset Read Only 195 cfgRacTuneLocalServerVideo Read Write 196 cfgRacTuneLocalConfigDisable Read Write 196 cfgRacTuneWebserverEnable Read Write 196 cfgRacTuneVirtualConsoleAuthorizeMultipleSessions Read Write 197 cfgRacTunePluginType Read Write 197 ifeRacManagedNodeOs 198 ifcRacMnOsHostname Read Only 198 ifcRacMnOsOsName Read Only 198 cfgRacVirtual 199 cfgRacVirMediaAttached Read Write 199 cfgVirMediaBootOnce Read Write 199 cfgVirtualFloppy
2. The following sections provides information about the objects in the cfgIPv6URL group cfgIPv6URLstring Read Only Description The iDRAC6 IPv6 URL Legal Values A string of up to 80 characters Default lt blank gt cfglpmiSerial This group is applicable only for iDRAC6 and specifies properties used to configure the IPMI serial interface of the BMC F NOTE The cfglpmiSerial object group is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC cfglpmiSerialBaudRate Read Write Description Specifies the baud rate for a serial connection over IPMI Legal Values 9600 19200 57600 115200 Default 57600 iDRAC6 and CMC Property Database Group and Object Descriptions 267 cfglpmiSerialConnectionMode Read Write Description When the iDRAC6 cfgSerialConsoleEnable property is set to 0 disabled the iDRAC6 serial port becomes the IPMI serial port This property determines the IPMI defined mode of the serial port In Basic mode the port uses binary data with the intent of communicating with an application program on the serial client In Terminal mode the port assumes that a dumb ASCII terminal is connected and allows very simple commands to be entered Legal Values 0 Terminal 1 Basic Default l cfglpmiSerialChanPrivLimit Read Write Description Specifies the maximum privilege level allowed on the IPMI serial channel Legal Values 2 User 3
3. 25 Supported RACADM Subcommands 26 Other Documents YouMayNeed 30 2 RACADM Subcommand Details 33 Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands 33 and lt subcommand gt 34 help and help lt subcommand gt 36 AND a els OOR ET HI ESE IE 37 chassisaction 37 clearasrscreen 2 39 ClOSESSI goes oss Ed BRA ASD RE ee HAE ES 39 ClrFaGIOG EER ve EE RE RE avg hs Be hk ee EE 41 Contents Contents cmcchangeover 42 Hi 2 ne OR ua 2 s EE ER Q eee sa 42 Ha OR a Da EE k us Q k DK 45 Coreduip ER RE RR A on Shee 46 coredumpdelete 47 deploye o Cu GE EE DR ene ae ee 47 feature cos k uu he Eee eR GS Bes 50 featurecard auauua ee ee ee 52 fwupdate 54 getassettag a 61 getchassisname 61 getconfig ER oe pe 62 getdeinfo 22 2244 TE RENEE bee wae a 64 getflexaddr __ 66 getfanreqinfo 2 69 getioinio or ed t t ett Bs y Ba ORS 2 71 getkvminfo SS SS SS SS e 72 getled gt ra ME wee Sts RYE BAe 73 getmacaddress 74 getmodinrffo0 _ _ _ 19 gemiccigu s EE puas DR ie dd en he Qua 9 8 81 getpbinffo Ee Ese 83 getpminfo EE Ee Ese 85 g
4. Synopsis racadm getniccfg RACADM Subcommand Details 81 Sample Output The getniccfg subcommand displays an appropriate error message if the operation is not successful Otherwise on success the output is displayed in the following format IPv4 settings NIC Enabled IPv4 Enabled 1 Ra DHCP Enabled IP Address 10 35 0 64 Subnet Mask 255 255 255 0 Gateway 10 35 2051 IPv6 settings IPv6 Enabled 0 DHCP6 Enabled 1 IP Address 1 _ Gateway Link Local Address P Address P Address P Address P Address P Address P Address ony OU A U N ll Address P Address 9 P Address 10 P Address 11 P Address 12 P Address 13 P Address 14 H H H H H H H H H H H H H tg 82 RACADM Subcommand Details IP Address 15 LOM Status NIC Selection Dedicated Link Detected Yes Speed 10Mb s Duplex Mod Half Duplex K NOTE IPv6 information is displayed only if IPv6 is enabled in iDRAC6 NOTE LOM Status is displayed only for iDRAC6 on Rack and Tower servers and is not displayed for iDRAC6 Enterprise on Blade servers getpbinfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getpbinfo Displays power budget status information Synopsis racadm getpbinfo Example racadm getpbinfo Power Budget Status System Input Power 700 W Peak System Power 0 W Pea
5. racadm lt subcommand gt Example racadm getconfig g idracinfo racadm getsysinfo SSH Telnet RACADM racadm getconfig g lt groupname gt o lt objectname gt i lt indexnumber gt racadm lt subcommand gt Example racadm getconfig g idracinfo racadm getsysinfo Remote RACADM racadm r u p getconfig g lt groupname gt o lt objectname gt i lt indexnumber gt racadm r u p lt subcommand gt Example racadm r u p getconfig g idracinfo racadm r u p getsysinfo 24 Introduction RACADM Command Options Table 1 1 lists the options for the RACADM command Table 1 1 RACADM Command Options Option Description r lt raclpAddr gt Specifies the controller s remote IP address r lt raclpAddr gt lt port Use lt port number gt if the iDRAC6 port number is not number gt the default port 443 u lt usrName gt Specifies the user name that is used to authenticate the command transaction If the u option is used the p option must be used and the i option interactive is not allowed p lt password gt Specifies the password used to authenticate the command transaction If the p option is used the i option is not allowed S Specifies that RACADM should check for invalid certificate errors RACADM stops the execution of the command with an error message if it detects an invalid certificate i lt indexnumber gt Specifies the index
6. 10800 For iDRAC6 on Rack and Tower Servers 300 For iDRAC6 Enterprise on Blade Servers and CMC 1800 F NOTE If 0 no timeout the network connection does not send keep alive packets to probe the client Otherwise keep alive packets are sent to guarantee that the 180 client is responding iDRAC6 and CMC Property Database Group and Object Descriptions cfgSsnMgtTelnetidleTimeout Read Write Description Legal Values Default Defines the Telnet idle timeout This property sets the amount of time in seconds that a connection is allowed to remain idle there is no user input The session is cancelled if the time limit set by this property is reached Changes to this setting do not affect the current session you must log out and log in again to make the new settings effective An expired Telnet session displays the following error message In case of iDRAC6 on Rack and Tower Servers Connection timed out In case of iDRAC6 Enterprise on Blade Servers Session timed out Closing the session After the message is displayed the system returns you to the shell that generated the Telnet session 0 No timeout 0 10800 For CMC 60 10800 For iDRAC6 on Rack and Tower Servers 300 For iDRAC6 Enterprise on Blade Servers and CMC 1800 F NOTE If 0 no timeout the network connection does not send keep alive packets to probe the client Otherwise keep alive packets are sent to guarantee that the client
7. Legal Values 576 1500 Default 1500 F NOTE IPv6 requires a minimum MTU of 1280 If IPv6 is enabled and cfgNetTuningMtu is set to a lower value the CMC uses an MTU of 1280 cfgSensorRedundancy This group is applicable only for iDRAC6 and is used to set the power supply redundancy The following sections provides information about the objects in the cfgSensorRedundancy group F NOTE The cfgSensorRedundancy object group is applicable only for iDRAC6 on Rack and Tower Servers and not for IDRAC6 Enterprise on Blade Servers iDRAC6 and CMC Property Database Group and Object Descriptions 213 cfgSensorRedundancylndex Read Only Description Index for the sensor redundancy group being read Only power Supply redundancy is supported Legal Values l Default None cfgSensorRedundancyPolicy Read Write Description Sets the power supply redundancy policy Legal Values 2 N A for sytems that are not supported 3 Non Redundant 4 1 1 Redundant 4 2 1 Redundant 16 2 2 Redundant Default Any legal value at that particular execution instance cfgSensorRedundancyCapabilities Read Only Description Returns the redundancy capabilities in the form of a bitmask This bitmask allows the user to know which values can be set for cfgSensorRedundancyPolicy Legal Values A bit mask More than 1 bit can be set at a time to indicate multiple redundancy support 0 N A for sytems that are not supported l Non Redundant 2 1
8. RACADM Subcommand Details 147 148 To delete all partitions re initialize the vFlash SD card racadm vflashsd initialize To get the status of operation on partition 1 racadm vflashpartition status i 1 To get the status of all existing partitions racadm vflashpartition status a To list all existing partitions and its properties racadm vflashpartition list To get the partition size racadm getconfig g cfgvflashpartition o cfgvflashpartitionsize i 1 To display the emulation type racadm getconfig g cfgvflashpartition I 1 o cfgvflashpartitionemulatiotype To display the label for the partition that is visible to the operating system racadm getconfig g cfgvflashpartition i 1 o cfgvflashPartitionlabel To display the format type of the partition racadm getconfig g cfgvflashpartition i 1 o cfgvflashPartitionFormatType To change a read only partition to read write racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAccessType 1 To attach a partition to the host operating system racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAttachState 1 RACADM Subcommand Details vmdisconnect F NOTE To use this subcommand you must have Access Virtual Media permission F NOTE This option is applicable only to iDRAC6 Subcommand Description vmdisconnect Allows a user to disconnect another user s Virtual Media session Once disconnected
9. a Fan 1 Fan 2 Fan 3 Fan 4 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Ambient_Temp O Oi O AO Os OD RANK KK AK Not K O K OK 14495 14505 4839 14527 14505 4835 14521 K 1 4826 21 rpm rpm rpm rpm rpm rpm rpm rpm rpm lt units gt celcius 7250 7250 2344 7250 7250 2344 7250 7250 2344 x TG N A RACADM Subcommand Details We gt 4500 4500 4500 4500 4500 4500 4500 4500 4500 lt uc gt 40 m lt senType gt Num lt sensorName gt lt status gt lt AC OK status gt PWR 1 PS 1 Online OK PWR 2 PS 2 Online OK PWR 3 PS 3 Online OK PWR 4 PS 4 Slot Empty N A PWR 5 PS 5 Failed OK PWR 6 PS 6 Slot Empty N A racreset F NOTE To use this subcommand for CMC you must have Chassis Administrator privilege and for IDRAC you must have Configure iDRAC permission F NOTE When you issue a racreset subcommand iDRAC6 may require up to two minutes to return to a usable state Subcommand Description racreset Issues a reset to IDRAC6 The reset event is written into iDRAC6 log F NOTE You must reboot your system after performing a hard reset of iDRAC6 as described in Table 2 28 Synopsis racadm racreset hard soft Table 2 28 describes the racreset subcommand options Table 2 28 racreset Subcommand Options Option Description hard A hard reset performs a deep reset operation on the remote access controller A hard reset should onl
10. cfgRacTunelpBlkEnable Read Write Description Enables or disables the IPv4 address blocking feature of iDRAC6 or CMC Legal Values 1 TRUE 0 FALSE Default 0 cfgRacTunelpBlkFailCount Read Write Description The maximum number of login failures to occur within the window cfgRacTunelpBlkFailWindow before login attempts from the IP address are rejected Legal Values 2 16 Default 5 192 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacTunelpBlkFailWindow Read Write Description Legal Values Default Defines the time span in seconds that the failed attempts are counted When failure attempts age beyond this limit they are dropped from the count For iDRAC6 10 65535 For CMC 2 655356 60 cfgRacTunelpBlkPenaltyTime Read Write Description Legal Values Default Defines the time span in seconds that session requests from an IP address with excessive failures are rejected For iDRAC6 10 655356 For CMC 2 655356 300 cfgRacTuneSshPort Read Write Description Legal Values Default Specifies the port number used for iDRAC6 or CMC SSH interface For iDRAC6 1 65535 For CMC 10 65535 22 cfgRacTuneTelnetPort Read Write Description Legal Values Default Specifies the port number used for iDRAC6 or CMC Telnet interface For iDRAC6 1 65535 For CMC 10 65535 23 F NOTE For CMC the following port numbers are reserved
11. getssinfo Displays a list of users that are connected to iDRAC6 The following information is displayed Session ID Username IP address if applicable Session type for example serial or Telnet Login date and time in MM DD YYYY HH MM SS format Based on the Session ID SSNID or the user name User the iDRAC administrator can close the respective sessions or all the sessions using the closessn subcommand For more information see closessn on page 39 Synopsis racadm getssninfo A u lt username gt Table 2 23 describes the getssninfo subcommand options Table 2 23 getssninfo Subcommand Options Option Description A The A option eliminates the printing of data headers u The u lt username gt user name option limits the printed output to only the detail session records for the given user name If an symbol is given as the user name all users are listed Summary information is not printed when this option is specified RACADM Subcommand Details 93 Examples racadm getssninfo SSNID Type User IP Address Login Date Time 6 GUI root 192 168 0 10 04 07 2010 12 00 34 racadm getssninfo A root 143 166 174 19 Telnet NONE racadm getssninfo A u root 143 166 174 19 Telnet NONE bob 143 166 174 19 GUI NONE getsvctag K NOTE To use this subcommand you must have Login to iDRAC permission Subc
12. racadm setassettag m chassis 783839 33 OT racadm setassettag 783839 33 The asset tag was changed successfully setchassisname F NOTE To use this subcommand you must have Administrator privilege Subcommand Description setchassisname Sets the name of the chassis in the LCD Synopsis racadm setchassisname lt name gt F NOTE Chassisname is a maximum of 64 non extended ASCII characters Example racadm setchassisname dellchassis 1 The chassis name was set successfully RACADM Subcommand Details 117 setflexaddr F NOTE To use this subcommand you must have Chassis Configuration Administrator privilege Subcommand Description setflexaddr Enables disables FlexAddress on a particular slot fabric F NOTE If the fabric type is determined to be Infiniband the operation is canceled andthe command returns an error If the FlexAddress feature is not activated the command returns an error V NOTE The server must be powered off to change the slot state All servers must be powered off to change the fabric state The MAC WWN addresses must be managed locally not by an external console to use this command Synopsis racadm setflexaddr i lt slot gt lt state gt f lt fabricName gt lt state gt lt slot gt 1 to 16 lt fabricName gt A B C lt state gt 0 or 1 where 0 is disable and 1 is enable Table 2 32 describes the setflexaddr subcommand options
13. 255 cfgServerPowerSupplyFwVer Read Only 255 cfgServerPowerSupplyCurrentDraw Read Only 255 cfgServerPowerSupplylype 256 cfglPv6LanNetworking 256 cfglPv6Enable Read Write 256 cfglPv6Address 256 cfglPv6Address1 Read Write a a 257 cfglPv6Gateway Read Write 257 cfglPv6PrefixLength Read Write 257 cfglPv6AutoConfig Read Write 258 cfglPv6LinkLocalAddress Read Only 258 cfglPv6Address2 Read Only 258 Contents 17 cfglPv6Address3 Read Only 259 cfglPv6Address4 Read Only 259 cfglPv6Address5 Read Only 259 cfglPv6Address6 Read Only 259 cfglPv6Address7 Read Only 260 cfglPv6Address8 Read Only 260 cfglPv6Address9 Read Only 260 cfglPv6Address10 Read Only 260 cfglPv6Address11 Read Only 261 cfglPv6Address12 Read Only 261 cfglPv6Address13 Read Only 261 cfglPv6Address14 Read Only 261 cfglPv6Address15 Read Only 262 cfgIPv6DNSServersFromDHCP6 Read Write 262 cfglPv6DNSServer1 Read Write 262 cfgIPv6DNSServer2 Read Write 263 cfgCurrentLanNetworking Read only 264 cfgNicCurrentlpAddress 264 cfgNicCurrentNetmask 264 cfgNicCurrentGateway 264 cfgNicCurrentDhcpWasUsed 26
14. Description Displays the current power consumption Legal Values A string of up to 32 characters Default Current power consumption cfgServerPeakAmperage Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the current peak power consumption Legal Values A string of up to 32 characters Default Current peak power consumption iDRAC6 and CMC Property Database Group and Object Descriptions 249 cfgServerPeakAmperageTimeStamp Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the timestamp of the current peak power consumption Legal Values A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where DD Day of the week e MM Month Date Date YYYY Year HH hour MM Minutes SS Seconds Default Timestamp of the current peak power consumption cfgServerCumulativePowerConsumption Read Only K NOTE This object is applicable only for iDRAC6 Description Displays the cumulative power consumption Legal Values A string of up to 32 characters Default Cumulative power consumption 250 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerCumulativePowerConsumptionTimeStamp Read Only F NOTE This object is applicable only for iDRAC6 Description Legal Values Default Displays the timestamp of the cumulative power consumption A string of up to 32 characters Tim
15. NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getioinfo Displays general information about the I O modules on the chassis F NOTE The fabric type may be any supported 1 0 fabric type such as Ethernet Fiber Channel and Infiniband Synopsis racadm getioinfo RACADM Subcommand Details 71 Example racadm getioinfo lt IO gt lt Name gt lt Type gt lt Presence gt lt POST gt lt Power gt lt Role gt switch 1 Dell Ethernet Gigabit Present OK ON Master Passthrough Ethernet switch 2 N A None Not Present N A N A N A switch 3 Brocade 4424 Fibre Present OK ON Master Channel 4 switch 4 N A None Not Present N A N A N A switch 5 N A None Not Present N A N A N A switch 6 N A None Not Present N A N A N A getkvminfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getkvminfo Displays iKVM module information Synopsis racadm getkvminfo Example racadm getkvminfo lt module gt lt presence gt lt model gt lt FW Version gt lt status gt KVM Present Avocent iKVM Switch 00 05 00 04 Ready 72 RACADM Subcommand Details getled F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getled Displays the LED settings on a module blinking not blinking or unknown for empty slots Synopsis racadm getled m lt module gt T
16. Table 2 47 cfglpmiPet Commands Action Command Enable the alert racadm config g cfgIpmiPet o cfgIpmiPetAlertEnable i 1 1 Set the destination racadm config g cfgIpmiPet o e mail IP address cfgIpmiPetAlertDestIpAddr i 1 192 168 0 110 140 RACADM Subcommand Details Table 2 47 cfglpmiPet Commands Action Command View the current test racadm getconfig g cfglpmiPpet i trap settings lt index gt where lt index gt is a number from to 4 Synopsis racadm testtrap i lt index gt Table 2 48 describes the testtrap subcommand options Table 2 48 testtrap Subcommand Options Option Description i Specifies the index of the trap configuration to use for the test Valid values are from 1 to 4 traceroute K NOTE To use this subcommand you must have Administrator permission Subcommand Description traceroute Traces the network path of routers that packets take as they are forwarded from your system to a destination IPv4 address Synopsis racadm traceroute lt IPv4 address gt racadm traceroute 192 168 0 1 traceroute to 192 168 0 1 192 168 0 1 30 hops max 40 byte packets 1 192 168 0 1 192 168 0 1 0 801 ms 0 246 ms 0 253 ms RACADM Subcommand Details 141 traceroute6 F NOTE To use this subcommand you must have Administrator permission Subcommand Description traceroute6 Traces the network path of routers that packets take as they ar
17. F NOTE The dash character cannot be the first character of the string regardless of whether the string is quoted RACADM Subcommand Details 33 There are different escaping rules for single quoting versus double quoting For double quoting The following characters must be escaped by prepending a backslash dollar sign double quote single quote back quote N backslash For example use the following for a string that contains the special characters and For single quoting e No character escaping is necessary A single quote cannot be used even with a backslash escaped F NOTE An empty string may be specified as either using double quotes or using single quotes and lt subcommand gt F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description Displays all the subcommands you can use with the racadm command and a one line description of each subcommand lt subcommand gt Displays the syntax for the specified command F NOTE You can also use the help and help lt subcommand gt commands to obtain the same information Synopsis racadm racadm lt subcommand gt 34 RACADM Subcommand Details Example for racadm F NOTE The following output example shows only part of the actual output for the racadm command Descriptions shown in this example may vary slightly from the descr
18. Fan 1 Present O OK Fan 2 Present O OK Fan 3 Present O O Fan 4 Present O OK Fan 5 Present O OK Fan 6 Present O OK Fan 7 Present O O Fan 8 Present O O Fan 9 Present O OK PS 1 Present Online OK 80 RACADM Subcommand Details PS 2 Not Present A A N A PS 3 Present Online OK PS 4 Not Present A A N A PS 5 Not Present A A N A PS 6 Not Present A A N A CMC 1 Present Primary OK N A CMC 2 Not Present A A N A Switch 1 Not Present A A N A Switch 2 Not Present A A N A Switch 3 Not Present A A N A Switch 4 Not Present A A N A Switch 5 Not Present A A N A Switch 6 Not Present A A N A Server 1 Not Present A A N A Server 2 Present OFF OK Server 3 Present ON OK S YW Server d Present ON OK Server 5 Present ON OK Server 6 Present ON OK 1234567 Server 7 Present ON OK Server 8 Not Present N A N A N A Server 9 Not Present N A N A N A Server 10 Extension 2 N A N A N A Server 11 Not Present N A N A N A Server 12 Present ON OK Server 13 Not Present N A N A N A Server 14 Present ON OK 0000015 Server 15 Present ON OK Server 16 Present ON OK KVM Present ON OK I0 Cable Present ON OK ABC1234 FPC Cable Present ON OK ABC1234 F NOTE For CMC only a power state of Primary denotes Active CMC getniccfg F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description getniccfg The getniccfg subcommand displays the current NIC settings
19. NIC3 Ethernet 00 24 e8 2e c5 SCSI 00 24 e8 2e c5 NIC4 Ethernet 00 24 e8 2e c5 iSCSI 00 24 e8 2e c5 Watchdog Information Recovery Action None Present countdown value 15 seconds Initial countdown value 15 seconds Examples racadm getsysinfo A s System Information Powerl 2195 racadm System System System System S EF23VQ 0023 Hostname ervice Pack 2 ON getsysinfo w s Information Model Revision BIOS Version BMC Firmware Version Service Tag OS Nam e Host Name Server 2003 Power Status Watchdog Information Recovery Action Present countdown value Initial countdown value 9 RACADM Subcommand Details Power T O 2 3 0 17 48192 racdev103 OFF None Microsoft Windows 2000 version 5 0 0 seconds 0 seconds cd ce lie d0 dl1 d2 Edge 2900 A08 1 0 Build Number Edge 2900 Microsoft Windows Limitations The Hostname and OS Name fields in the getsysinfo output display accurate information only if Dell OpenManage Server Administrator is installed on the managed system If it is not installed these fields may be blank or inaccurate An exception to this are VMware operating system names which are displayed even if Server Administrator is not installed on the managed system gettracelog F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description gett
20. This option is applicable only to iDRAC6 Subcommand Description usercertview Displays the user certificate or user CA certificate that exists on iDRAC6 Synopsis racadm usercertview t lt type gt A i lt index gt Table 2 50 describes the sslcertview subcommand options Table 2 50 sslcertview Subcommand Options Option Description t Specifies the type of certificate to view either the user certificate or the user CA certificate 1 user certificate 2 user CA certificate A Prevents printing headers labels i Index number of the user Valid values are 1 16 version F NOTE This option is applicable only for iDRAC6 Subcommand Description version Displays the RACADM version information Synopsis racadm version 144 RACADM Subcommand Details vflashsd F NOTE To use this subcommand you must have Access Virtual Media privilege F NOTE This option is applicable only to iDRACE Subcommand Description vflashsd Allows you to initialize or get the status of the vFlash SD card The initialize operation removes all existing partitions and resets the card The status operation displays the status of the last operation performed on the card Synopsis racadm vflashsd initialize racadm vflashsd status vflashpartition F NOTE To use this subcommand you must have Access Virtual Media privilege F NOTE This option is applicable only to iDRAC
21. lt opt ion is set to 0 Virtual Console is enabled 106 RACADM Subcommand Details netstat F NOTE To use this subcommand you must have Execute Diagnostic Commands permission Subcommand Description netstat Displays the routing table and the current connections Synopsis racadm netstat ping F NOTE To use this subcommand you must have Execute Diagnostic Commands or Configure iDRAC permission Subcommand Description ping Verifies that the destination IP address is reachable from iDRAC6 with the current routing table contents A destination IP address is required An ICMP echo packet is sent to the destination IP address based on the current routing table contents Synopsis racadm ping lt ipaddress gt RACADM Subcommand Details 107 ping6 F NOTE To use this subcommand for CMC you must have Administrator privilege for CMC and for iDRAC you must have Execute Diagnostic Commands or Configure iDRACE permission Subcommand Description ping6 Verifies that the destination IPv6 address is reachable from iDRAC6 or CMC or with the current routing table contents A destination IPv6 address is required An ICMP echo packet is sent to the destination IPv6 address based on the current routing table contents Synopsis racadm ping6 lt ipv address gt Examples racadm iping6 10 9 72 254 IPING6 10 9 72 254 10 9 72 254 56 data bytes 64 bytes from 10 9 72 254 icmp_seq 0 tt1l
22. s 192 168 0 20 259 259 2595 0 1 92 168 0 1 The server was deployed successfully NOTE The deploy command generates an error when used on the extension slot of a multi slot server racadm deploy m server 9 192 168 0 11 255 255 255 0 192 168 0 1 ERROR Server in slot 9 is an extension of the server in slot 1 racadm deploy m server 7 u root p calvin s 6 64 10 RACADM Subcommand Details 49 feature F NOTE To use this subcommand to deactivate FlexAddress you must have Chassis Configuration Administrator privilege A user with login privileges can view status only Subcommand Description feature Displays all active chassis features The information displayed includes feature name date activated and the serial number of the SD card used to activate the feature Dell Feature Cards may contain more than one feature After any feature included on a Dell Feature Card is activated on a chassis any other features that may be included on that Dell Feature Card cannot be activated on a different chassis F NOTE To deactivate FlexAddress features the chassis must be powered off Synopsis racadm feature s racadm featur d c lt featurename gt racadm featur a c ExtendedStorage racadm featur 1 c ExtendedStorage racadm featur 2 c ExtendedStorage racadm featur r c ExtendedStorage Table 2 6 feature Subcommand Options Option Des
23. 0x17ff8db iDRAC6 and CMC Property Database Group and Object Descriptions 253 cfgAlertingSourceEmailName Description E mail address used to send e mail notifications when an event occurs Legal Values None Default None Examples racadm getconfig g cfgAlerting o cfgAlertingEnable 1 racadm config g cfgAlerting o cfgAlertingEnable 1 Object value modified successfully cfgServerPowerSupply This group is applicable only for IDRAC6 and contains information related to the power supplies The following sections provide information about the objects in the cfgServerPowerSupply group F NOTE The cfgServerPowerSupply object group is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers F NOTE The getconfig subcommand always shows eight cfgServerPowerSupply indexes even if two power supplies are installed in the system or the system supports a maximum of two power supply units For the uninstalled and unsupported units all the objects in the cfgServerPowerSupply group displays a value of 0 cfgServerPowerSupplylndex Description Index of the power supply unit Legal Values Integer from 1 8 Default None F NOTE Indexes from 1 8 are supported to support up to 8 power supply units If any power supply unit is not present cfgServerPowerSupplyOnlineStatus is absent and for all the other properties it is 0 254 iDRAC6 and CMC Property Database Group and
24. 19 D2 1E A2 RACADM Subcommand Details N A N A Not Installed Not Installed Not Installed 00 1E 4F FF F 0 BO OO LE 4F FF F O B1 00 1D 09 72 0 1 8 21 00 00 1B 3 2 0E CF 34 N A N A N A N A N A 00 18 9 F2 8B FF A 00 18 9 F3 8B FF A 00 1D 0 78 09 71 E 00 1D 0 79 09 71 E 21 00 00 1B 3 2 0E EF 30 N A N A Not Installed Not Installed N A N A Not Installed Not Installed Not Installed OO 1E 4F FF F0 B2 OO 1E 4F FF F0 B3 00 1D 09 72 01 CA 21 01 00 1B 32 2B CE 3 4 N A N A N A N A N A 00 18 8B FF A9 F4 00 18 8B FF A9 F5 00 1D 09 71 EO 7A 00 1D 09 71 E0 7B 21 01 00 1B 32 2E EF 3 0 N A N A Not Installed Not Installed Server Fibre Present Not Installed Not 14 C Channel 4 Installed Server Gigabit Extension 7 N A OO 1E 4F FF F O00 1E 4F FF 15 A Ethernet 0 B4 F0 B6 iSCSI Extension 7 N A OO 1E 4F FF F O00 1E 4F FF 0 B5 F0 B7 Server Gigabit Extension 7 N A 00 1D 09 71 E 00 1D 09 71 15 B Ethernet 1 20 E1 22 iSCSI Extension 7 N A 00 1D 09 71 E 00 1D 09 71 12 E1 23 Server Fibre Extension 7 N A 21 00 00 1B 3 21 00 00 1B 15 C Channel 4 2 17 3A 66 32 37 3A 6 6 Server 16 N A Not Present N A N A N A Switch 1 None Present N A 00 00 00 00 0 N A 0 00 Switch 2 None Present N A 00 00 00 00 0 N A 0 00 Switch 3 None Present N A 00 00 00 00 0 N A 0 00 Switch 4 None Present N A 00 00 0
25. 95 e Hexadecimal value For example 0x12 Octal value For example 007 e ASCII value For example a ASCII values may be represented using the following Escape Key codes followed by any alphabetic a z A Z N followed by the listed special characters N For CMC This key specifies the character that aborts the serial text console connect or racadm connect command NOTE The CTRL key is represented by using the carat character NOTE The CTRL key does not generate a character by itself but must be struck simultaneously with another key to generate a character For example striking both the CTRL key and the key simultaneously rather than sequentially is denoted as Configuration options The value must start with the character and be followed by one of the characters a z A Z 1 String of up to 4 characters For iDRAC lt Ctrl gt lt gt Fo CMC NOTE For information on using RACADM commands for special characters see Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands on page 33 iDRAC6 and CMC Property Database Group and Object Descriptions 183 cfgSerialConsoleldleTimeout Read Write Description The maximum number of seconds to wait before an idle serial session is disconnected Legal Values 0 No timeout 60 1920 Default For iDRAC6 300 For CMC 1800 cfgSerialConsoleNoAuth Read Write Description Enables or di
26. A server 13 Not Present None N A None N A server 14 Not Present None N A None N A server 15 Not Present None N A None N A server 16 Not Present None N A None N A RACADM Subcommand Details 65 getdcinfo n lt Server gt lt Presence gt lt DC1 Model Name gt lt DC2 Model Name gt server 1 Present None None server 2 Not Present None None server 3 Not Present None None server 4 Present None Broadcom M5708t server 5 Not Present None None server 6 Not Present None None server 7 Not Present None None server 8 Present LPe1105 M4 None server 9 Extension 1 None None server 10 Not Present None None server 11 Not Present None None server 12 Not Present None None server 13 Not Present None None server 14 Not Present None None server 15 Not Present None None server 16 Not Present None None getflexaddr F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getflexaddr Displays enabled disabled status for the entire chassis If used with i the command displays MACS WWN on a per slot basis F NOTE If FlexAddress is not activated on the chassis the command displays server assigned MAC WWN addresses If the slot is empty the command leaves the server assigned MAC WWN addresses blank If an external console controls the MAC WWN addresses the command displays an externally managed message Synopsis racadm getflexaddr i lt slotNum gt 66 RACADM Subco
27. A N A N A N A N A 00 18 8B FF A9 F4 N A OO 1E 4F FF F0 B6 N A N A N A N A N A N A N A Display Ethernet and iSCSI MACS of all LOMs mezzanine cards racadm getmacaddress a lt Name gt lt Type gt lt Presence gt lt BMC MAC lt NIC1 MAC lt NIC2 MAC Address gt Address gt Address gt CMC N A Present N A OO 1E 4F 1F 3 N A C 58 16 RACADM Subcommand Details Server 1 A Server 1 B Server 1 Server 2 A Server 2 B Server 2 C Server 3 Server 4 A Server 4 B Server 4 E Server 5 A Server 5 B Server 5 Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 N A Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 Present OO 1E AF 2A AF 7B Present Present Present Present Present 00 22 19 D2 1E 84 Present Present Present Present Not Present N A Present 45 2A Present Not Present Present Present Present FE E2 Present Present Present Present RACADM Subcommand Details 00 18 8B FF 00 19 B9 FF OO 1E AF 2A D 3 97 OO 1E AF 2A D 3 98 Not Installed Not Installed Not Installed N A N A Not Installed Not Installed Not Installed N A 00 18 8B FF A A 02 00
28. A 5 N A 14 SLOT 14 ON 342 W 5 N A 15 SLOT 15 ON 140 W 5 16 SLOT 16 ON 125 W 5 N A 84 RACADM Subcommand Details getpminfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getpminfo Displays power management status information Synopsis racadm getpminfo Example racadm getpminfo Real Time Power Statistics System Input Power 600 W 188 BTU hr Peak System Power 600 W 188 BTU hr Peak System Power Start Time 16 02 10 01 16 2008 Peak System Power Timestamp 06 32 55 01 26 2009 Minimum System Power 400 W 177 BTU hr Minimum System Power Start Time 22 43 21 01 21 2008 Minimum System Power Timestamp 06 32 55 01 26 2009 System Idle Power 68 W 188 BTU hr System Potential Power 68 W 188 BTU hr System Input Current Reading 31 2 A Real Time Energy Statistics System Energy Consumption 6 4 kWh System Energy Consumption Start Time 16 02 10 01 16 2008 System Energy Consumption Timestamp 16 02 10 01 16 2008 System Power Status Chassis Power State ON Overall Power Health OK Redundancy No RACADM Subcommand Details 85 System Power Policy Configuration System Input Power Cap 7928 W 7928 BTU hr 108 Surplus for Peak Performance 7000 W 6130 BTU hr Redundancy Policy None Dynamic PSU Engagement Enabled No Power Budgeting System Input Max Power C
29. CMC racadm setled m server 1 1 1 LED state was set successfully F NOTE The setled command generates an error when used on the extension slot of a multi slot server racadm setled m server 9 1 1 ERROR Server in slot 9 is an extension of the server in slot 1 Example for iDRAC6 racadm setled 1 1 LED state was set successfully 120 RACADM Subcommand Details setniccfg F NOTE To use the setniccfg command you must have Configure iDRAC permission Subcommand Description setniccfg The setniccfg subcommand sets the iDRAC6 IP address It displays an error message if the requested operation could not be performed or a success message if the operation completed successfully F NOTE The terms NIC and Ethernet management port may be used interchangeably Synopsis racadm setniccfg d racadm setniccfg d6 racadm setniccfg s lt IPv4Address gt lt netmask gt lt IPv4 gateway gt racadm setniccfg s6 lt IPv6 Address gt lt IPv6 Prefix Length gt lt IPv6 Gateway gt racadm setniccfg o Table 2 34 describes the setniccfg subcommand options Table 2 34 setniccfg Subcommand Options Option Description d Enables DHCP for the NIC default is DHCP disabled d6 Enables AutoConfig for the NIC It is enabled by default S Enables static IP settings The IPv4 address netmask and gateway can be specified Otherwise the existing static settings ar
30. Description getslotname Displays the name and hostname if available of all 16 slots or of a specified slot indicated by the slot number in the chassis Optionally this command can be used to find if the slot name or hostname is displayed in the CMC User Interface or with the getslotname i lt slot ID gt command If the hostname is not available the static slot name is used Synopsis racadm getslotname racadm getslotname i lt slot ID racadm getslotname h RACADM Subcommand Details 91 Table 2 22 describes the getslotname subcommand options Table 2 22 getslotname Subcommand Options Option Description None Displays the slot name for all 16 slots in the chassis i sslot ID gt Specifies the ID of the slot Legal values 1 16 h Specifies whether to use the slot name or the hostname if available 1 use hostnames 0 use slotnames Example racadm gets lt Slot lt S 1 OO UP QO N HOLOO HOU BU ND Gy Gy Gy Oy Q Oy CQ n Uy Uy K Oy S U wn lotname lot Name gt LOT O1 ebserver0l ebserver3 LOT 04 LOT 05 LOT 06 LOT 07 LOT 08 LOT 09 LOT 10 LOT 11 EOT 12 LOT 13 LOT 14 LOT 15 LOT 16 lt Host name gt WXP 8GRB221 WXP 3190WEecet5 racadm getslotname i 1 Webserver l 92 RACADM Subcommand Details getssninfo F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description
31. FF E3 23 Ethernet active iSCSI 00 1C 23 CD AC D5 OO 1E C9 FF E3 24 active slot1 Bl Gigabit 00 1D 09 71 B3 60 00 1E C9 FF E3 25 active Ethernet iSCSI 00 1D 09 71 B3 61 00 1E C9 FF E3 26 active slot1 B2 Gigabit 00 1D 09 71 B3 62 00 1E C9 FF E3 27 active Ethernet iSCSI 00 1D 09 71 B3 63 00 1E C9 FF E3 28 active slot1 C1 Fiber 10 00 00 00 C9 63 20 01 00 1E C9 FF E3 29 active Channel 4 2 51 08 slot1 C2 Fiber 10 00 00 00 C9 63 20 02 00 1E C9 FF E3 29 active Channel 4 51 0D 68 RACADM Subcommand Details getfanreqinfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getfanreqinfo Displays fan request for Servers and Switches in percent Synopsis racadm getfanreginfo Example racadm getfanreginfo Ambient Temperatur 38 Server Module Fan Request Table Fan Request lt Slot gt lt Server Name gt 1 SLOT O1 2 SLOT 02 3 SLOT 03 4 SLOT 04 5 SLOT 05 6 SLOT 06 7 SLOT 07 fwupdate 8 SLOT 08 9 SLOT 09 10 SLOT 10 Lt SLOT 11 lt Blade Type gt PowerEdge PowerEdge PowerEdge PowerEdge PowerEdge N A PowerEdge PowerEdge N A N A N A 600 905 710 610 610 710 lt Power State gt ON ON ON ON ON N A ON ON N A lt Presence gt Present Present Present Present Present Not Present Present Present Not Present Extension N A 2 Extension N A 3 RACA
32. Object Descriptions cfgServerPowerSupplyMaxInputPower Read Only Description Displays the AC input rated power in Watts Legal Values A string of up to 32 characters Default 0 cfgServerPowerSupplyMaxOutputPower Read Only Description Displays the AC output rated power in Watts Legal Values A string of up to 32 characters Default 0 cfgServerPowerSupplyOnlineStatus Read Only Description Displays the status of the power supply unit Legal Values Present Absent 2 Failure 3 Predictive failure Default 0 cfgServerPowerSupplyFwVer Read Only Description Displays the firmware version of the power supply unit Legal Values A string up to 8 characters Default Null cfgServerPowerSupplyCurrentDraw Read Only Description Displays the instantaneous current consumption in 0 1 Amps Legal Values A string of up to 32 characters Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 255 cfgServerPowerSupplyType Description Displays whether the power supply is AC or DC Legal Values A string of up to 32 characters Default 0 cfglPv6LanNetworking This group is used to configure the Pv6 over LAN networking capabilities F NOTE Use this object with the config or getconfig subcommands K NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE Use the m option to apply this setting to iDRAC The follow
33. Rack and Tower Servers 4 For iDRAC6 Enterprise on Blade Servers 2 cfgSsnMgtWebserverTimeout Read Write Description Legal Values Default Defines the Web server timeout This property sets the amount of time in seconds that a connection is allowed to remain idle there is no user input The session is cancelled if the time limit set by this property is reached Changes to this setting do not affect the current session you must log out and log in again to make the new settings effective An expired Web server session logs out the current session 60 10800 1800 iDRAC6 and CMC Property Database Group and Object Descriptions 179 cfgSsnMgtSshldleTimeout Read Write Legal Values Default Description Defines the secure shell idle timeout This property sets the amount of time in seconds that a connection is allowed to remain idle there is no user input The session is cancelled if the time limit set by this property is reached Changes to this setting do not affect the current session you must log out and log in again to make the new settings effective An expired secure shell session displays the following error message In case of iDRAC6 on Rack and Tower Servers Connection timed out In case of iDRAC6 Enterprise on Blade Servers Session timed out Closing the session After the message is displayed the system returns you to the shell that generated the Secure Shell session 0 No timeout 0
34. Table 2 32 setflexaddr Subcommand Options Option Description i lt slot gt lt state gt Enables disables FlexAddress for the specified slot lt fabricName gt lt state gt Enables disables FlexAddress for the specified fabric 118 RACADM Subcommand Details Example racadm setflexaddr i 1 0 Slot 1 FlexAddress state set successfully racadm setflexaddr f A 1 Fabric A FlexAddress state set successfully racadm setflexaddr f idrac 1 setled F NOTE To use this subcommand you must have Login access and Administrator privilege for CMC and Configure iDRAC permission for iDRAC Subcommand Description setled Sets the state blinking or not blinking of the LED on the specified module Synopsis for iDRAC6 racadm setled 1 lt ledState gt Synopsis for CMC racadm setled m lt module gt 1 lt ledState gt RACADM Subcommand Details 119 Table 2 33 describes the setled subcommand options Table 2 33 setled Subcommand Options Option Description m lt module gt NOTE This option is applicable for CMC only Specifies the module whose LED you want to configure lt module gt can be one of the following e server n where n 1 16 switch n where n 1 6 cmc active chassis l lt ledstate gt Specifies whether the LED should blink lt ledstate gt can be one of the following 0 no blinking 1 blinking Example for
35. YY I YH FH KR 26 Introduction Table 1 3 RACADM Subcommands continued Subcommand iDRACE6 on Blade Servers iDRAC6 on Rack and Tower Servers CMC Telnet Local SSH Serial Remote RACADM RACADM Telnet Local Remote Telnet Remote SSH S RACADM RACADM SSH RACADM Serial deploy s feature featurecard fwupdate getassettag getchassisname getconfig getdcinfo getfanreqinfo getflexaddr getioinfo getkvminfo getled getmacaddress getmodinfo getniccfg getpbinfo getpminfo getraclog S MS MA MM MM R Wi S MAS RW RR G B R L MA R R MM R MS MAS RRR S lt RW BW BWW MM R MS R lt RRR G MARK MA MM MM R MS MAS RRR Q R R L RW BW MA WWW NS RRS N 93 G B R S BW BW R BW BW BW R MS MAS RRR LK 4 6 S SESSE SESSE SE SLAE BS lt lt lt lt lt S 4 S S SESSE GW S S SE SE SE SE SE SE Introduction 27 Table 1 3 RACADM Subcommands continued Subcommand iDRAC6 on Blade iDRACGonRackand CMC Servers Tower Servers ash RACADM RACADM ss RACADM RACADM Re RACADM getractime VY PYL PT getredundancymode H R BH R R R y y std YY v LL vv YL getsensorinfo RR R RR RK VS getslotname RR KR KK RK lt getssninfo VY PYP PP getsvetag VY PYL PL getsysinfo VY PP VV PP gettracelog VY GF FHF GF HSH getversion RR R RR RK VY g
36. an alert instance Legal Values 1 4 Default 1 cfgTrapsEnable Description Enables or disables event traps on the CMC Legal Values 1 TRUE 0 FALSE Default None cfgTrapsAlertDestlpAddr Description Sets the IP address that receives the alert Legal Values A string representing a valid IP address For example 192 168 0 20 Default None cfgTrapsCommunityName Description Sets the community string identical to the community name used for authentication The community string acts as a password shared between different hosts over the network This community string value must match with that of the other hosts for any kind of communication through SNMP Legal Values A string representing the community name Default None 188 iDRAC6 and CMC Property Database Group and Object Descriptions Example racadm getconfig g cfgTraps i 2 cfgTrapsIndex 2 cfgTrapsEnable 1 cfgTrapsAlertDestIpAddr cfgTrapsCommunityName public cfgRacTuning F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option Use the m option to apply this setting to IDRAC This group is used to configure various IDRAC6 or CMC configuration properties such as valid ports and se
37. and operation requires user name and password u The user name specified in an appropriate format for the selected lt username gt authentication method That is Active Directory users are specified as user_name domain_name p lt password gt The password for the indicated user account RACADM Subcommand Details 137 Table 2 46 testfeature Subcommand Options Option Description d lt bitmask gt A bitmask specified as a hexadecimal value to select various diagnostic messaging levels This option is optional NOTE d option is not supported with the remote racadm interface Subcommands testfeature f ad Synopsis testfeatur f ad u lt username gt p lt password gt d lt diagnostic message level gt This subcommand tests Active Directory configuration using simple authentication user name and password Use the optional d switch to obtain additional diagnostic information as needed This subcommand when executed performs the following Checks command syntax Verifies whether the required system resources are available e Validates Active Directory configuration Verifies the SSL certificate and if the certificate signing request key exists Acquires LDAP and Global Catalog Service records from DNS Acquires user privileges from the Active Directory server Checks the time to acquire user privileges with the allotted time to login F NOTE In the ev
38. bit masks for users with one or more privileges Table 3 4 Sample Bit Masks for User Privileges User Privilege s Privilege Bit Mask The user is not allowed to access 0x00000000 iDRAC or CMC The user may only login to 0x00000001 iDRAC or CMC and view iDRAC or CMC and server configuration information The user may login to iDRAC or 0x00000001 0x00000002 0x00000003 CMC and change configuration The user may login to iDRAC 0x00000001 0x00000040 0x00000080 access Virtual Media and access 0x000000C1 Virtual Console cfgUserAdminUserName Read Write Description The name of the user for this index The user index is created by writing a string into this name field if the index is empty Writing a string of double quotes deletes the user at that index You cannot change the name You must delete and then recreate the name The string cannot contain forward slash backslash period at symbol or quotation marks NOTE This property value must be unique among user names Legal Values A string of up to 16 ASCII characters Default root User 2 lt blank gt All others 174 iDRAC6 and CMC Property Database Group and Object Descriptions cfgUserAdminPassword Write Only Description The password for this user User passwords are encrypted and cannot be seen or displayed after the property is written Legal Values A string of up to 20 ASCII characters Default P 3 3 3k 3
39. config g cfgEmailAlert o address cfgEmailAlertAddress i 1 userl mycompany com Set the custom message racadm config g cfgEmailAlert o that is sent to the cfgEmailAlertCustomMsg i 1 This is a destination e mail address test Ensure that the SMTP IP racadm config g cfgRemoteHosts o address is configured cfgRhostsSmtpServerIpAddr 192 168 0 152 properly View the current e mail racadm getconfig g cfgEmailAlert i alert settings lt index gt where lt index gt is a number from to 4 136 RACADM Subcommand Details Table 2 45 describes the testemail subcommand options Table 2 45 testemail Subcommands Option Description i Specifies the index of the e mail alert to test Output Success Test e mail sent successfully Failure Unable to send test e mail testfeature Subcommand Description testfeature Generic test command consisting of several sub commands that allow you to verify the configuration and operation of specific features Table 2 46 describes the testfeature subcommand options Table 2 46 testfeature Subcommand Options Option Description f Specifies the feature name testfeature supports the following lt feature gt features ad Tests Active Directory configuration using simple authentication user name and password adkrb Tests Active Directory configuration using Kerberos authentication ldap Tests LDAP configuration
40. configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option F NOTE For any network property changes on iDRAC6 to be successfully executed through RACADM you must first enable iDRAC6 NIC The following sections provides information about the objects in the cfgLanNetworking group cfgNiclPv4Enable Read Write Description Enables or disables iDRAC6 or CMC IPv4 stack Legal Values 1 TRUE 0 FALSE Default l 156 iDRAC6 and CMC Property Database Group and Object Descriptions cfgNicSelection Read Write F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Specifies the current mode of operation for the RAC network interface controller NIC Table 3 2 describes the supported modes Legal Values 0 Shared 1 Shared with Failover LOM2 2 Dedicated 3 Shared with Failover All LOMs iDRAC6 Enterprise only Default 0 iDRAC6 Express 2 IDRAC6 Enterprise Table 3 2 lists the supported cfgNicSelection modes Table 3 2 cfgNicSelection Supported Modes Mode Description Shared Used if the host server integrated NIC is shared with the RAC on the host server This mode enables configurations to use the same IP address on the host server and the RAC for common accessibility on the network Shared with Failover Enables teaming capabilities be
41. directs getconfig to write the entire iDRAC6 configuration to a configuration file This file can be used for batch configuration operations using the config subcommand g The g lt groupName gt or group option can be used to display the configuration for a single group The groupName is the name for the group used in the racadm cfg files If the group is an indexed group use the i option h The h or help option displays a list of all available configuration groups in alphabetical order This option is useful when you do not remember exact group names 62 RACADM Subcommand Details Table 2 13 getconfig Subcommand Options Option Description i The i lt index gt or index option is valid only for indexed groups and can be used to specify a unique group The lt index gt is a decimal integer from 1 through n where n can vary from 1 to maximum number of indexes a particular group supports If i lt index gt is not specified a value of 1 is assumed for groups which are tables that have multiple entries The index is specified by the index value not a named value 0 The o lt objectname gt or object option specifies the object name that is used in the query This option is optional and can be used with the g option u The u lt username gt or user name option can be used to display the configuration for the specified user The lt username gt option is the login name for the user v Th
42. for iDRAC6 Description The iDRAC6 IPv6 thirteenth address Legal Values String representing a valid IPv6 entry Default cfglPv6Address14 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 fourteenth address Legal Values String representing a valid IPv6 entry Default iDRAC6 and CMC Property Database Group and Object Descriptions 261 cfglPv6Address15 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 fifteenth address Legal Values String representing a valid IPv6 entry Default cfgIPv6DNSServersFromDHCP6 Read Write Description Specifies whether cfgIPv6DNSServerl and cfgIPv6DNSServer2 are static or DHCP IPv6 addresses NOTE For CMC this property is used only if cfglPv6AutoConfig is set to 1 true Legal Values 1 TRUE 0 FALSE Default For iDRACE 0 For CMC 1 cfgIPv6DNSServer1 Read Write Description An IPv6 DNS server address NOTE For CMC this property is used only if cfglPv6DNSServersFromDHCP6 is set to 0 false Legal Values A string representing a valid Pv6 entry For example 2001 DB8 1234 5678 9ABC DE 1 1 C00C BEEF Default 262 iDRAC6 and CMC Property Database Group and Object Descriptions cfglPvGDNSServer2 Read Write Description An IPv6 DNS server address NOTE This property is only valid if cfgIPv6DNSServersFromDHCP6 is set to 0 false Legal Values A string representing a valid Pv6 ent
43. groupName gt specifies the group containing the object that is to be set 0 The o lt objectName gt lt Value gt or object option must be used with the g option This option specifies the object name that is written with the string lt value gt RACADM Subcommand Details 43 Table 2 3 config Subcommand Options and Descriptions continued Option Description i The i lt index gt or index option is valid only for indexed groups and can be used to specify a unique group The lt index gt is a decimal integer from 1 through n where n can vary from to maximum number of indexes a particular group supports If i lt index gt is not specified a value of is assumed for groups which are tables that have multiple entries The index is specified by the index value not a named value c The c or check option is used with the config subcommand and allows the user to parse the cfg file to locate syntax errors If errors are found the line number and a short description of what is incorrect are displayed Writes do not occur to iDRAC6 This option is a check only Output This subcommand generates error output for any of the following reasons Invalid syntax group name object name index or other invalid database members RACADM CLI failures This subcommand returns an indication of the number of configuration objects that were written out of the total objects in the cfg file Examples
44. in BTU hr for the entire chassis The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting 9264 56931 BTU hr 43221 BTU hr cfgChassisPowerCapFBTU Read Write Description Legal Values Default Indicates the maximum power consumption limit in BTU hr for the entire chassis Use cfgChassisCapFBTU when power consumption is to be changed regardless of whether server throttling is required The command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration 9264 56931 BTU hr 56931 BTU hr iDRAC6 and CMC Property Database Group and Object Descriptions 227 cfgChassisPowerCapPercent Read Write Description Indicates the power consumption limit as a percentage The percentage is computed mathematically as the minimum power percent maximum power minimum power The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting Legal Values 16 100 Default 100 cfgChassisPowerCapFPercent Read Write Description Indicates the power consumption limit as a percentage The percentage is computed mathematically as the minimum power percent maximum power minimum power Use cfgChassisPowerCapF Percent when power consumption is to be changed regardless of whether server throttling is required Legal Values 16 100
45. is responding cfgSerial This group contains configuration parameters for IDRAC6 or CMC services One instance of the group is allowed F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege iDRAC6 and CMC Property Database Group and Object Descriptions 181 The following sections provides information about the objects in the cfgSerial group F NOTE The cfgSerial object group is applicable for iDRAC6 Enterprise on Blade Servers for only two properties cfgSerialTelnetEnable 1 and cfgSerialSshEnable 1 cfgSerialBaudRate Read Write Description Sets the baud rate on iDRAC6 or CMC serial port Legal Values For iDRAC6 9600 28800 57600 115200 For CMC 2400 4800 9600 19200 28800 38400 57600 115200 Default For iDRAC6 57600 For CMC 115200 cfgSerialConsoleEnable Read Write Description Enables or disables the RAC or CMC serial console interface Legal Values 1 TRUE 0 FALSE Default For iDRACE 0 For CMC 1 182 iDRAC6 and CMC Property Database Group and Object Descriptions cfgSerialConsoleQuitKey Read Write Default Legal value Default For iDRAC6 This key or key combination terminates Virtual Console text for iDRAC when using the console com2 command The cfgSerialConsoleQuitKey value can be represented by one of the following Decimal value For example
46. lt path gt m lt module gt racadm fwupdate f lt ftp server ip address or FQDN gt lt username gt lt password gt d lt path gt m lt module gt racadm fwupdate u m iominf lt n gt racadm fwupdate s m lt module gt racadm fwupdate c m lt module gt RACADM Subcommand Details 55 For remote RACADM racadm fwupdate p u d lt firmware image F NOTE When using FTP if you provide the full path to the image file on the CLI then the CMC uses that path to locate that file on the host If you do not provide a full path then the CMC searches the home directory of the specified user for the file if the host system is running Linux or another variant of UNIX If the host system is running Windows then a default folder such as CAftproot is searched F NOTE When attempting to run firmware update task using racadm fwupdate command if the firmware image path length is greater than 64 characters remote RACADM client exits with the error message ERROR Specified path is too long Input Table 2 11 describes the fwupdate subcommand options F NOTE The p option is supported on local and remote RACADM and is not supported with the serial Telnet ssh console The p option is also not supported on Linux operating systems Table 2 11 describes the fwupdate subcommand options Table 2 11 fwupdate Subcommand Options Option Description u For iDRAC The update option performs a checksu
47. managed server Legal Values A string of up to 255 characters Default lt blank gt iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacVirtual F NOTE This object is applicable only to iDRAC6 This group contains parameters to configure the iDRAC6 Virtual Media feature One instance of the group is allowed The following sections provides information about the objects in the cfgRacVirtual group cfgRacVirMediaAttached Read Write Description This object is used to attach virtual devices to the system via the USB bus When the devices are attached the server recognizes valid USB mass storage devices attached to the system This is equivalent to attaching a local USB CDROM floppy drive to a USB port on the system When the devices are attached they can be connected to the virtual devices remotely using iDRAC6 Web interface or the CLI Setting this object to 0 causes the devices to detach from the USB bus Legal Values 0 Detach 1 Attach 2 Auto Attach Default 0 cfgVirMediaBootOnce Read Write Description Enables or disables the Virtual Media Boot Once feature of iDRAC6 If this property is enabled when the host server is rebooted this feature attempts to boot from the virtual media devices if the appropriate media is installed in the device Legal Values 1 TRUE 0 FALSE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 199 cfgVirtualFloppyEmulation Read W
48. must begin with a letter Default null cfgLDAPSRVLookupServiceName F NOTE This object is applicable only to CMC Description Configures the service name to be used in the SRV lookup Legal Values String of maximum length of 254 characters Default ldap cfgLdapRoleGroup This group allows the user to configure role groups for LDAP F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege K NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option For CMC this object configures Generic LDAP Role group Descriptions and defines the CMC privileges that LDAP authenticated users are granted iDRAC6 and CMC Property Database Group and Object Descriptions 221 cfgLDAPRoleGroup is indexed containing instances numbered from 1 to 5 Each object instance consists of a pair of properties cfgLDAPRoleGroupDN an LDAP distinguished name DN cfgLDAPRoleGroupPrivilege a CMC privilege map Each LDAP authenticated user assumes the total set of CMC privileges assigned to the matching LDAP distinguished names that the user belongs to That is if the user belongs to multiple role group DNs the user receives all associated privileges for those DNs The following sections provides information about the objects in the cfg
49. name and hostname if available of all 16 slots or of a specified slot indicated by the slot number in the chassis Optionally this command can be used to set whether the slot name or hostname is displayed in the CMC User Interface or with the getslotname i lt slot ID gt command If the hostname is not available the static slot name is used F NOTE The 0MSA server agent must be present and running on the server to use the Display Hostname feature If the agent is not running the setting is ignored For more information see the Dell OpenManage Server Administrator User s Guide at dell com support manuals Synopsis racadm setslotname i lt slotID gt lt slotname gt racadm setslotname h lt enabled gt Table 2 36 describes the setslotname subcommand options Table 2 36 setslotname Subcommand Options Option Description lt slotID gt Displays the location of the slot in the chassis Legal values 1 16 lt slotname gt The new name to assign to the slot lt enabled gt Sets whether the server s hostname is used for display purposes 1 enabled Legal values 0 1 124 RACADM Subcommand Details Example racadm setslotname i 3 mserver3 The slot name was set successfully setsysinfo F NOTE To use this subcommand you must have Administrator privilege Subcommand Description setsysinfo Sets the name or location of the chassis Synopsis racadm setsysinfo c chass
50. number for the indexed group if applicable g lt groupname gt Specifies the group name if applicable o lt objectname gt Specifies the object name if applicable Table 1 2 provides the supported RACADM interfaces for iDRAC6 Enterprise and iDRAC6 Express Table 1 2 Supported RACADM Interfaces iDRAC Type Local RACADM SSH TelnetRACADM Remote RACADM iDRAC6 Enterprise ef Sf Af iDRAC6 Express A s CMC s Sf s Supported B Not supported Introduction 25 F NOTE Multiple instances of remote racadm can be executed on a management station while only one instance oflocal racadm can be executed on a managed node Supported RACADM Subcommands Table 1 3 provides the list of RACADM subcommands and their corresponding interface support For detailed information of the RACADM subcommands including syntax and valid entries see RACADM Subcommand Details on page 33 Table 1 3 RACADM Subcommands Subcommand iDRAC6 on Blade iDRACGonRackand CMC Servers Tower Servers Ri RACADM RACADM sais RACADM RACADM Re RACADM and RE R KKK VG lt subcommand gt arp sZ v LR Z lt chassisaction RR KR RA KR lt lt clearasrscreen vY S Q Q FGF KER closessn VY lt lt S Q JF clrraclog VY lt lt S lt lt lt clrsel VY lt JI Q JL cmechangeover RR R RR RK VHA config VY lt TV Pr connect RR KR RR RK lt lt coredump YVR YF GR GF KR coredumpdelete
51. of up to 254 characters Default lt blank gt cfgRacSecCsrCountryCode Description Specifies the CSR Country Code CC Legal Values A string of up to 254 characters Default US iDRAC6 and CMC Property Database Group and Object Descriptions 285 cfgRacSecCsrEmailAddr Description Specifies the CSR email address Legal Values A string of up to 254 characters Default lt blank gt Example racadm getconfig g cfgRacSecurityData i 1 cfgRacSecCsriIndex 1 cfgRacSecCsrKkeySize 1024 cfgRacSecCsrCommonName iDRAC_10 35 1105 10 cfgRacSecCsrOrganizationName OrgName cfgRacSecCsrOrganizationUnit OrgUnit cfgRacSecCsrLocalityName LocalityName cfgRacSecCsrStateName TX cfgRacSecCsrCountryCode US cfgRacSecCsrEmailAddr abc xy z com 286 iDRAC6 and CMC Property Database Group and Object Descriptions iDRAC6 and CMC Property Database Group and Object Descriptions 287 288 iDRAC6 and CMC Property Database Group and Object Descriptions Deprecated Commands Groups and Objects This section provides information about the deprecated RACADM subcommands groups and objects in the current release Few commands groups or objects are deprecated in RACADM either due to a new command or object replacing the functionality of an existing command or object or the feature is no longer supported For the deprecated command or object If you run the racadm help command the deprecated command is not displayed in the command
52. platform event filter Legal Values A string of up to 255 characters Default The name of the index filter cfglpmiPeflndex Read Write Description Specifies the index of a specific platform event filter Legal Values For iDRAC6 on Rack and Tower Servers 1 22 For iDRAC6 Enterprise on Blade Servers 1 9 Default The index value of a platform event filter object cfglpmiPefAction Read Write Description Specifies the action that is performed on the managed server when the alert is triggered NOTE For iDRAC6 on Rack and Tower servers this object is read only for indexes 20 21 and 22 Legal Values 0 None 1 Power Down 2 Reset 3 Power Cycle Default 0 cfglpmiPefEnable Read Write Description Enables or disables a specific platform event filter Legal Values 1 TRUE 0 FALSE Default l 236 iDRAC6 and CMC Property Database Group and Object Descriptions cfglpmiPet This group is applicable only for iDRAC6 and is used to configure platform event traps on the managed server The following sections provides information about the objects in the cfgIpmiPet group cfglpmiPetindex Read Only Description Unique identifier for the index corresponding to the trap Legal Values 1 4 Default The index value of a specific platform event trap cfglpmiPetAlertDestlpAddr Read Write Description Specifies the destination IPv4 address for the trap receiver on the network The trap receiver receives an SNMP trap when
53. racadm config g cfgLanNetworking o cfgNicIpAddress 10 35 10 100 Sets the cfgNiclpAddress configuration parameter object to the value 10 35 10 110 This IP address object is contained in the group cfgLanNetworking racadm config f myrac cfg Configures or reconfigures iDRAC6 The myrac cfg file may be created from the getconfig command The myrac cfg file may also be edited manually as long as the parsing rules are followed F NOTE The myrac cfg file does not contain passwords To include passwords in the file you must enter them manually If you want to remove password information from the myrac cfg file during configuration use the p option 44 RACADM Subcommand Details connect Subcommand Description connect Connects to the switch or server serial console F NOTE You cannot use this subcommand with remote RACADM Synopsis racadm connect b lt server n gt racadm connect b lt switch n gt Table 2 4 describes the connect subcommand options Table 2 4 connect Subcommand Options Option Description b Connects to the switch or console using the binary mode This is an optional argument a server or a switch must be present server n or Server or switch to connect to switch n server n where n 1 16 switch n where n lt al a2 bl b2 cl c2 gt F NOTE If you use the b option reset the CMC to terminate the connect operation F NOTE See th
54. redirection Legal Values 1 TRUE 0 FALSE Default 1 cfgSerialSshEnable Read Write Description Enables or disables the secure shell SSH interface on iDRAC6 or CMC Legal Values 1 TRUE 0 FALSE Default l iDRAC6 and CMC Property Database Group and Object Descriptions 185 Example racadm getconfig g cfgSerial fgSeria LBaudRate s115200 fgSerial fgSerial Conso Consol eEnable 1 eQuitKey Consol IdleTimeout 1800 fgSerial fgSerial Consol eNoAuth 0 Conso fgSerial fgSerial Consol eCommand eColumns 0 fgSerial fgSerial Telnet HistorySize 8192 Enable 0 OO QO DAG AR fgSerial SshEnable 1 cfgSerialTelnetEnable Read Write Description Legal Values Default Enabl CMC es or disables the Telnet console interface on i DRAC6 or 1 TRUE 0 FALSE 0 cfgOobSnmp This group contains parameters to configure the SNMP agent and trap capabilities of IDRAC6 or CMC One instance of the group is allowed The CMC SNMP agent supports the standard RFC1213 mib 2 and the Dell enterprise specific MIB F NOTE For CMC use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurab
55. retrieve the keys Legal Values AlphaNumeric character values with only underscore as special character Default Poweredge cfgRacSecurity F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property you must have Chassis Configuration Administrator privilege This object property is specific to CMC only F NOTE For iDRAC6 this group is replaced with cfgRacSecrityData This group is used to configure settings related to CMC SSL certificate signing request CSR feature The properties in this group must be configured before generating a CSR from CMC For more information on generating certificate signing requests see the subcommand sslkeyupload on page 133 iDRAC6 and CMC Property Database Group and Object Descriptions 281 The following sections provides information about the objects in the cfgRacSecurity group cfgRacSecCsrCommonName Read Write Description Specifies the CSR Common Name CN that must be an IP or CMC name as given in the certificate Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrOrganizationName Read Write Description Specifies the CSR Organization Name O Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrOrganizationUnit Read Write Description Specifies the CSR Organization Unit OU Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrLoca
56. string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week MM Month Date Date e YYYY Year HH hour e MM Minutes e SS Seconds Default Maximum power value during the last hour cfgServerPowerLastDayMinPower Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the minimum power value during the last day Legal Values A string of up to 32 characters Default Minimum power value during the last day 244 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerLastDayMinPowerTime Read Only F NOTE This object is applicable only for iDRAC6 Description Legal Values Default Displays the timestamp of minimum power value during the last day A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week MM Month Date Date e YYYY Year e HH hour MM Minutes SS Seconds Minimum power value during the last day cfgServerPowerLastDayMaxPower Read Only F NOTE This object is applicable only for iDRAC6 Description Legal Values Default Displays the maximum power value during the last day A string of up to 32 characters Maximum power value during the last day iDRAC6 and CMC Property Database Group and Object Descriptions 245 cfgServerPowerLastDayMaxPowerTime Read Only F NOTE This object is applicab
57. the Web based interface reflects the correct connection status Enables a iDRAC6 user to disconnect all active Virtual Media sessions The active Virtual Media sessions can be displayed in iDRAC6 Web based interface or by using the RACADM subcommands such as remoteimage or getssninfo Synopsis racadm vmdisconnect vmkey F NOTE To use this subcommand you must have Access Virtual Media permission F NOTE This option is applicable only to iDRACE Subcommand Description vmkey When a custom Virtual Media key image is uploaded to the RAC the key size becomes the image size The vmkey subcommand can be used to reset the key back to its original default size which is 256 MB on iDRAC6 RACADM Subcommand Details 149 Synopsis racadm vmkey lt action gt If action is configured as reset the vFlash memory is reset to the default size of 256 MB and removes all data from it F NOTE This command is deprecated from iDRAC6 1 5 and iDRAC6 3 0 releases onwards The functionality of this command is now covered by vf lashsd initialize While execution ofthe vmkey reset command is successful it is recommended to use the vflashsd initialize command For more information see vflashsd on page 145 150 RACADM Subcommand Details IDRAC6 and CMC Property Database Group and Object Descriptions The iDRAC6 and CMC property database contains the configuration information for iDRAC6 and CMC Data is organized by asso
58. the firmware update file resides For CMC Specifies the source path where the firmware image resides Default Designated TF TP default directory on that host for the file if g option is absent If g is used defaults to directory configured on the TFTP server P For iDRAC The p or put option is used to update the firmware file from the managed system to iDRAC6 The u option must be used with the p option NOTE This option is not applicable for CMC T The rollback option is used to rollback to the standby firmware NOTE This option is not applicable for CMC cC Cancels the current firmware update of a module NOTE This option is applicable only for CMC RACADM Subcommand Details 57 Table 2 11 fwupdate Subcommand Options continued Option Description m NOTE This option is applicable only for CMC lt modul Specifies the module or device to be updated lt module gt is one of the following values e cmc active default cmc standby kvm server n where n 1 16 server generation where generation iDRAC or iDRAC6 e iominf n where n 1 6 NOTE CMC version 3 00 accepts IPv4 IPv6 or fully qualified domain names FQDN for both FTP and TFTP servers NOTE You can specify the cmc active and cmc standby modules at the same time along with one or more server n modules This enables the devices to be updated together NOTE See Updating the IOM Infrastr
59. the members of the group if it is set to 0 the user name provided by the login user is used to compare to the members of the group This does not impact the search algorithm for the bind iDRAC6 always searches the userDN and uses the userDN to bind For CMC if enabled the CMC performs DN matching otherwise the CMC uses the user name provided at login for matching 1 TRUE Use the userDN from the LDAP Server 0 FALSE Use the userDN provided by the login user 1 cfgLdapBinddn Read Write Description Legal Values Default The distinguished name of a user used to bind to the server when searching for the login user s DN If not provided an anonymous bind is used This is optional but is required if anonymous bind is not supported String Maximum length 254 Null F NOTE If cfgLDAPBindDN is null and cfgLDAPBindPassword is null then the CMC attempts an anonymous bind cfgLdapBindpassword Write only Description Legal Values Default A bind password to use in conjunction with the bindDN The bind password is sensitive data and should be properly protected This is optional but is required if anonymous bind is not supported String Maximum length 254 Null iDRAC6 and CMC Property Database Group and Object Descriptions 219 cfgLdapSearchFilter Read Write Description A valid LDAP search filter This is used if the user attribute cannot uniquely identify the login user within the chosen ba
60. to iDRAC6 One instance of the group is allowed Displays current settings for and configures idle timeout properties for Web server Telnet SSH and RACADM sessions Changes to idle timeout settings take effect at the next login To disable idle timeout for a connection set this property to 0 Use the m option to apply this setting to iDRAC The following sections provides information about the objects in the cfgSessionManagement group cfgSsnMgtRacadmTimeout Read Write F NOTE This object is applicable for iDRAC6 on Rack and Tower Servers and CMC but not for iDRAC6 Enterprise on Blade Servers Description Defines the idle timeout in seconds for the Remote RACADM interface If a remote RACADM session remains inactive for more than the specified sessions the session closes Legal Values 10 1920 Default 60 Example racadm getconfig g cfgSessionManagement m server lt n gt o lt object name gt lt object value cfgSsnMgtWebserverTimeout 0 cfgSsnMgtTelnetIdleTimeout 0 cfgSsnMgtSshIdleTimeout 300 cfgSsnMgtRacadmTimeout 0 178 iDRAC6 and CMC Property Database Group and Object Descriptions cfgSsnMgtConsRedirMaxSessions Read Write F NOTE This object is applicable only for iDRAC6 Description Legal Values Default Specifies the maximum number of Virtual Console sessions allowed on iDRAC6 For iDRAC6 on Rack and Tower Servers 4 For iDRAC6 Enterprise on Blade Servers 1 2 For iDRAC6 on
61. while this operation completes Synopsis racadm racresetcfg RACADM Subcommand Details 113 remoteimage F NOTE To use this subcommand you must have Administrator permission Subcommand Description remoteimage Connects disconnects or deploys a media file on a remote server Synopsis racadm remoteimage lt options gt Table 2 29 describes the remoteimage subcommand options Table 2 29 remoteimage Subcommand Options and Descriptions Option Description c Connect the image d Disconnect image u Username to access the network share p Password to access the network share l Image location on the network share use double quotes around the location s Display current status a is assumed if not specified F NOTE If a drive is already connected this remote image c connect command terminates the previous command or the previous session Example racadm remoteimag c u user p password 1 10 94 192 100 CommonShare diskette img 114 RACADM Subcommand Details serveraction K NOTE To use this subcommand you must have Execute Server Control Commands permission Subcommand Description serveraction Enables users to perform power management operations on the host system Synopsis racadm serveraction lt action gt Table 2 30 describes the serveraction power control options Table 2 30 serveraction Subcommand Options String Des
62. with m option x Displays the extra MACs Ethernet or iSCSI for servers with additional LOM MACs and must be used with m option a Displays the Ethernet and iSCSI MAC WWN addresses for all iDRAC LOMs mezzanine cards When FlexAddress is enabled for a particular slot then the chassis assigned MAC WWN address is displayed 74 RACADM Subcommand Details Example Display iSCSI MAC addresses for all servers racadm Display i racadm getm acaddress SCSI MAC for server l getm t iscsi acaddress m s PVC ES iL Display extra iSCSI MACs for server l if available T Ses racadm getmacaddress m server l t iscsi Xx Display MAC for server 1 racadm getmacaddress m server l lt Name gt lt Presence gt lt BMC MAC Address gt lt NIC1 MAC lt NIC2 MAC Address gt Address gt server l Present 00 11 43 FD B7 2A 00 11 43 FD B7 00 11 43 FD B7 2B 2A server 9 Extension 1 N A 00 11 43 FD B7 00 11 43 FD B7 2D 2C Display extra MACs for server 1 if available racadm getmacaddress ms rver l x lt Name gt lt P server l Pre esence gt sent lt BMC MAC Address gt 00 11 43 FD B7 2A lt NIC1 MAC Address gt 00 11 43 FD B7 2A 003 11 43 ED BT 2C lt NIC2 MAC Address gt 00 11 43 FD B7 2B 00 11 43 FD B7 2D racadm getmacaddress lt Name gt lt Presence gt CMC Present Server 1 Present Server 2 Pre
63. 0 00 0 N A 0 00 Switch 5 None Present N A 00 05 1E 08 E N A B 0B Switch 6 N A Not Present N A N A N A F NOTE To use this subcommand you must have CMC Login User privilege F NOTE The service tag field is blank for modules that do not have service tags Subcommand Description getmodinfo Displays configuration and status information for all modules or a specified module server switch CMC fan unit power supply unit KVM or I2C cable in the chassis Synopsis racadm getmodinfo m lt module gt A RACADM Subcommand Details 79 Table 2 18 describes the getmodinfo subcommand options Table 2 18 getmodinfo Subcommand Options Option Description m lt module gt Specifies the module whose configuration and status information you want to view The default command no options displays information about all major components in the chassis lt module gt may be any of the following values server n where n 1 16 e switch n where n 1 6 e CMC n where n 1 2 fan n where n 1 9 ps n where n 1 6 chassis kvm io cable fpc cable A Suppresses headers and labels in the output Example racadm getmodinfo m switch l lt module gt lt presence gt lt pwrState gt lt health gt lt svcTag gt Switch 1 Present ON OK CG09074 racadm getmodinfo lt module gt lt presence gt lt pwrState gt lt health gt lt svcTag gt Chassis Present O Not OK ABC1234
64. 0 W cfgChassisInPowerServerAllocation 0 W cfgChassisInfrastructureInPowerAllocation 51 W cfgChassisTotalInPowerAvailable 0 W cfgChassisStandbyInPowerCapacity 0 W cfgChassisPowerClear Write Only cfgChassisPowerClearTimestamp 18 00 00 12 31 1969 cfgChassisPowerButtonEnable 1 cfgChassisAllow110VACOperation 0 Or iO O BOG G ITS cfgChassisMaxPowerConservationMode 0 cfgChassisPerformanceOverRedundancy 1 iDRAC6 and CMC Property Database Group and Object Descriptions 231 cfgSystemEnergyConsumptionClear Write Only racadm config g cfgChassisPower 0o cfgChassisPowerClear 1 Clears cfgChassisMinPower and cfgChassisPeakPower cfglpmiSol This group is applicable only for iDRAC6 and is used to configure the Serial Over LAN SOL capabilities of the system The following sections provides information about the objects in the cfgIpmiSol group cfglpmiSolEnable Read Write Description Enables or disables SOL Legal Values 1 TRUE 0 FALSE Default l cfglpmiSolBaudRate Read Write Description The baud rate for serial communication over LAN Legal Values 9600 19200 57600 115200 Default 115200 cfglpmiSolMinPrivilege Read Write Description Specifies the minimum privilege level required for SOL access Legal Values 2 User 3 Operator 4 Administrator Default 4 232 iDRAC6 and CMC Property Database Group and Object Descriptions cfglpmiSolAccumul
65. 1 Redundant 4 2 1 Redundant 8 242 Redundant Default 0 274 iDRAC6 and CMC Property Database Group and Object Descriptions cfgSensorRedundancyStatus Read Only Description Indicates the redundancy status The status is N A on platforms that does not support the power supply sensor redundancy Legal Values String N A Full Lost Degraded Default None cfgVFlashSD This group is applicable only for iDRAC6 and is used to configure the properties for the vFlash SD card The following sections provides information about the objects in the cfgVFlashSD group cfgVFlashSDEnable Read Write Description Enables or disables the vFlash SD card Legal Values 0 vFlash is disabled 1 vFlash is enabled Default l cfgVFlashSDSize Read Only Description Displays the size of the vFlash SD card in megabytes MB Legal Values A string of upto 64 characters Default lt card size gt iDRAC6 and CMC Property Database Group and Object Descriptions 275 cfgVFlashSDLicensed Read Only Description Displays whether a SD card or vFlash SD card is inserted The vFlash SD card supports the new enhanced vF lash features and the SD card supports only the limited vFlash features Legal Values 0 SD card is inserted 1 vFlash SD card is inserted Default None cfgVFlashSDAvailableSize Read Only Description Displays the available space in MB on the vFlash SD card that can be used to create new partition
66. 100MB Read Write 273 cfgNetTuningNicFullDuplex Read Write 273 cfgNetTuningNicMtu Read Write 273 cfgSensorRedundancy 273 cfgSensorRedundancylndex Read Only 274 cfgSensorRedundancyPolicy Read Write 274 cfgSensorRedundancyCapabilities Read Only 274 cfgSensorRedundancyStatus Read Only 275 Contents 19 20 Contents cfgVFlashSD 275 cfgVFlashSDEnable Read Write 275 cfgVFlashSDSize Read Only 275 cfgVFlashSDLicensed Read Only 276 cfgVFlashSDAvailableSize Read Only 276 cfgVFlashSDHealth Read Only 276 cfgVFlashSDWriteProtect Read Only 271 cfgVFlashPartition 277 cfgVFlashPartitionIndex ReadOnly 271 cfgVFlashPartitionSize ReadOnly 271 cfgVFlashPartitionEmulationType ReadWrite 278 cfgVFlashPartitionOSVolLabel ReadOnly 278 cfgVFlashPartitionFormatType ReadOnly 278 cfgVFlashPartitionAccessType Read Write 279 cfgVFlashPartitionAttachState Read Write 279 cfgLlogging 279 cfgLoggingSELOEMEventFilterEnable Read Write 279 cfgKMSProfile 280 cfgKMSProfilelndex Read only 280 cfgKMSProfilelPAddress Read Write 280 cfgKMSProfilePortNumber Read Write 280 cfgKMSProfileTimeout Read Write 281 cfgKMSProfileDeviceGroup Read Write 281 cfgRacSecur
67. 121 time 2 9 ms 10 9 72 254 ping statistics 1 packets transmitted 1 packets received 0 percent packet loss round trip min avg max 2 9 2 9 2 9 ms 108 RACADM Subcommand Details racdump F NOTE To use this subcommand for CMC you must have Administrator privilege and for iDRAC you must have Debug permission Subcommand Description racdump Provides a single command to get dump status and general iDRAC6 board information For CMC this subcommand displays the comprehensive chassis status and configuration state information as well as historic event logs Used for post deployment configuration verification and during debugging sessions The following information is displayed when the racdump subcommand is processed General system RAC information Coredump Session information Process information Firmware build information Racdump includes the following subsystems and aggregates the following RACADM commands Subsystem RACADM Command General System RAC information getsysinfo Session information getssinfo Sensor information getsensorinfo Switches information IO Module getioinfo Mezzanine card information Daughter card getdcinfo All modules information getmodinfo Power budget information getpbinfo KVM information getkvminfo RACADM Subcommand Details 109 Subsystem RACADM Command NIC information CMC module getniccfg Redundancy information getredundancymode Syn
68. 132 ssikeyupload 133 sslresetcty oc 2 6 ee ee EE EE 134 testemail __ 135 testfeature _ _ 136 festtrapu u n bate eee RR AE SE us lh Ed 139 traceroute usa Cu U ee ee Q 140 tracerouteB ee 141 usercertupload 141 usercertivieW 143 VerslON ss Gal he y uo a ER GS AES 143 Vilashsd u sy EE EN kuu ee hi ya oe 144 vfilashpartition 144 vmdisconnect 0 5 148 VNKGY 34 4 REM ee Ve N EDE ead 148 3 iDRAC6 and CMC Property Database Group and Object Descriptions 151 Displayable Characters 152 idRaclnfo Eg Re 154 idRacProductinfo Read Only 154 idRacDescriptionInfo Read Only 155 idRacVersionInfo Read Only 155 idRacBuildinfo Read Only 155 idRacName Read Only aa aaa 155 idRacType Read Only aaa aaa 155 cfgLanNetworking 156 Contents Contents cfgNiclPv4Enable Read Write cfgNicSelection Read Write cfgNicVLanEnable Read Write cfgNicVLanld Read Write cfgNicVLanPriority Read Write cfgDNSDomainNameFromDHCP Read Write cfgDNSDomainName Read Write cfgDNSRacName Read Write cfgDNSRegisterRac Read Write cfgDNSServersFromDHCP Read Write cf
69. 18 8B FF A A 03 Not Installed Not Installed Not Installed 00 19 B9 FF F CSUR 00 19 B9 FF F C 0D Not Installed Not Installed Not Installed OO 1E AF 2A D3 99 OO 1E AF 2A D3 9A Not Installed Not Installed Not Installed N A N A Not Installed Not Installed Not Installed N A 00 18 8B FF AA 04 00 18 8B FF AA 05 Not Installed Not Installed Not Installed 00 19 B9 FF FC 0E 00 19 B9 FF FC 0F Not Installed Not Installed Not Installed 71 Server 6 A Server 6 B Server 6 C Server 7 A Server 7 B Server 7 C Server 8 Server 9 Server 10 Server 11 Server 12 Server 13 A Server 13 B Server 13 6 Server 14 A Server 14 B 78 Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 Gigabit Ethernet iSCSI Gigabit Ethernet Fibre Channel 4 N A N A N A N A N A Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Fibre Channel 4 Gigabit Ethernet iSCSI Gigabit Ethernet iSCSI Present Present Present Present Present Present Present Present Present Not Not Not Not Not Present Present Present Present Present Present Present Present Present Present Present Present Present Present 00 22 19 D2 1D D4 OO 1E 4F FF FC DC N A N A N A N A N A 00 18 8B FF 45 26 00 22
70. 3 Severity Ok Description System Board SEL event log sensor for System Board log cleared was asserted getsensorinfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getsensorinfo Displays status for system sensors Synopsis racadm getsensorinfo Examples racadm getsensorinfo lt senType gt lt Num gt lt sensorName gt lt status gt lt reading gt lt units gt lt lc gt lt uc gt FanSpeed 1 Fan 1 O 4768 rpm 2344 14500 FanSpeed 2 Fan 2 O 4873 rpm 2344 14500 FanSpeed 3 Fan 3 O 4832 rpm 2344 14500 FanSpeed 4 Fan 4 O 4704 rpm 2344 14500 FanSpeed 5 Fan 5 O 4833 rpm 2344 14500 FanSpeed 6 Fan 6 O 4829 rpm 2344 14500 FanSpeed 7 Fan 7 O 4719 rpm 2344 14500 FanSpeed 8 Fan 8 Not OK 1 rpm 2344 14500 FanSpeed 9 Fan 9 O 4815 rpm 2344 14500 lt senType gt lt Num gt lt sensorName gt lt status gt lt reading gt lt units gt lt lc gt lt uc gt Temp 1 Ambient_Temp OK 22 celcius N A 40 90 RACADM Subcommand Details lt senType gt lt Num gt lt sensorName gt lt status gt lt AC OK status gt PWR 1 PS 1 Online OK PWR 2 BS 2 Online OK PWR 3 P5 3 Online OK PWR 4 PS 4 Slot Empty N A PWR 5 PS 5 Failed OK PWR 6 PS 6 Slot Empty N A lt senType gt lt Num gt lt sensorName gt lt status gt Cable IO Cable OK Cable FPC Cable OK getslotname F NOTE To use this subcommand you must have CMC Login User privilege Subcommand
71. 4 cfgDNSCurrentServer 264 cfgDNSCurrentServer2 264 cfgDNSCurrentDomainName 264 cfgNicCurrentIPv4Enabled 265 cfgCurrentIPv6LanNetworking Read only 265 cfgCurrentIPv6Enabled 265 cfgCurrentIPv6AutoConfigWasUsed 266 cfgCurrentLinkLocalAddress 266 cfgCurrentIPv6Address1 266 cfgCurrentIPv6Gateway 266 cfgCurrentIPv6DNSServersFromDHCP6 266 18 Contents cfgCurrentIPv6DNSServerl 266 cfgCurrentIPv6DNSServer2 266 cfgIPVGURL 0 0 00 267 cfgIPv6URLstring Read Only 267 cfglpmiSerial 267 cfglpmiSerialBaudRate Read Write 267 cfglpmiSerialConnectionMode Read Write 268 cfglpmiSerialChanPrivLimit Read Write 268 cfglpmiSerialFlowControl Read Write 268 cfglpmiSerialHandshakeControl Read Write 269 cfglpmiSerialLineEdit Read Write 269 cfglpmiSerialEchoControl Read Write 269 cfglpmiSerialDeleteControl Read Write 269 cfglpmiSerialNewLineSequence Read Write 270 cfglpmiSeriallnputNewLineSequence Read Write 270 cfgSmartCard 00 271 cfgSmartCardLogonEnable Read Write 271 cfgSmartCardCRLEnable Read Write 271 cfgNetTuning 272 cfgNetTuningNicSpeed 272 cfgNetTuningNicAutoneg Read Write 272 cfgNetTuningNic
72. 52 0 2011 02 02 Emb nic 1 Broadcom 5709 5 5 2 0 2011 02 02 Emb nic 1 Broadcom 5709 S 2 2011 02 02 Emb nic 1 Broadcom 5709 5 2 0 2011 02 02 Emb nic 1 PERC6 EMB raid 2 07 01 34 00 2011 02 02 BIOS Ord Rollback RACADM Subcommand Details 103 BIOS 123 0 Reinstall iDRAC 34 20 Reinstall PERC6 Emb raid 2 07 01 33 00 Rollback PERC6 Emb raid 2 07 01 33 00 Reinstall racadm getversion l m server 1 f bios lt Server gt lt Component gt lt Version gt lt Install Date gt server l BIOS 1 221 2010 11 22 ifconfig F NOTE To use this subcommand you must have Execute Diagnostic Commands or Configure iDRAC permission Subcommand Description ifconfig Displays the contents of the network interface table Synopsis racadm ifconfig Example racadm ifconfig eth0 Link encap Ethernet HWaddr 00 1D 09 FF DA 23 inet addr 10 35 155 136 Bcast 10 35 155 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 2550665 errors 0 dropped 0 overruns 0 frame 0 TX packets 0 errors 0 dropped 0 overruns 0 carrier 0 104 RACADM Subcommand Details collisions 0 txqueuelen 1000 RX bytes 272532097 259 9 MiB TX bytes 0 0 0 B krbkeytabupload F NOTE To use this subcommand you must have Configure iDRAC permission Subcommand Description krbkeytabupload Uploads a Kerberos keytab file Synopsis racadm krbkeytab
73. 6 Subcommand Description vflashpartition Allows you to perform the following Create an empty partition Create a partition using an image file Format a partition View available partitions Delete existing partitions Get the status of partitions F NOTE Create partition using image file is not supported in local RACADM RACADM Subcommand Details 145 Synopsis racadm vflashpartition create lt options gt racadm vflashpartition delete lt options gt racadm vflashpartition status lt options gt racadm vflashpartition list lt options gt Table 2 51 describes the vflashpartition subcommand options Table 2 51 vflashpartition Subcommand Options Option Description i lt index gt Index of the partition for which this command applies lt index gt must be an integer from to 16 NOTE For the standard SD card the index value is 1 because only one partition of size 256 MB is supported Options valid only with create action o lt label gt Label that is displayed when the partition is mounted on the operating system lt label gt must be a string up to six alphanumeric characters e lt type gt Emulation type for the partition lt type gt must be floppy cddvd or HDD 146 RACADM Subcommand Details Table 2 51 vilashpartition Subcommand Options continued Option Description t lt type gt Create a partition of type lt type gt lt type gt
74. ADM ss RACADM RACADM Ri RACADM sslresetcfg VY PL YL GF HH testemail VY PP s lt testfeature RR R 2 w lt testtrap VY YFG Q G Q QJ testfeature vy vos FGF RR traceroute 2 RR R VS traceroute6 lR y RR lt usercertupload RR Ry F KR usercertview RR yyy w RA version RI vittkvyvyv RY vflashsd vy vos GF RR vflashpartition YF I II FGF RR vmdisconnect vy vor FG RR Other Documents You May Need In addition to this guide you can access the following guides available on the Dell Support website at dell com support manuals Select Choose from a list of all Dell products and click Continue Click Software Monitors Electronics amp Peripherals Software Click Remote Enterprise System Management to view the documents for iDRAC Lifecycle Controller Chassis Management Controller and Baseboard Management Controller Management Utilities 30 Introduction The Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers User Guide provides information about configuring and using an iDRAC6 for blade servers to remotely manage and monitor your system and its shared resources through a network The Integrated Dell Remote Access Controller 6 iDRAC6 User Guide provides complete information about configuring and using an iDRAC6 for rack and tower servers to remotely manage and monitor your system and its shared resources through a network The CMC online Help provides information about using the CMC Web int
75. Allocation Read Only cfgChassisInfrastructurelnPowerAllocation Read Only ing ive Fe tes HA ha aes cfgChassisTotallnPowerAvailable Read Only cfgChassisStandbylnPowerCapacity Read Only cfgChassisPowerClear Write Only cfgChassisPowerClearTimestamp Read Only cfgChassisPowerButtonEnable Read Write cfgSystemEnergyConsumptionClear Write Only cfgipmiSol cfglpmiSolEnable Read Write cfglpmiSolBaudRate Read Write cfglpmiSolMinPrivilege Read Write cfglpmiSolAccumulatelnterval Read Write cfglpmiSolSendThreshold Read Write 228 229 229 229 230 230 230 230 230 230 230 230 231 231 232 232 232 232 233 233 cfglpmilan ahaaa aaa 233 cfglpmiLanEnable Read Write 233 cfglpmiLanPrivLimit Read Write 234 cfglpmiLanAlertEnable Read Write 234 cfglpmiEncryptionKey Read Write 234 cfglpmiPetCommunityName Read Write 234 cfglpmiPetIpv6 235 cfglpmiPetlPv6lndex Read Only 235 cfglpmiPetIPv6AlertDestIlpAddr 235 cfglpmiPetlPv6AlertEnable Read Write 235 cfglpmiPef 2 235 cfglpmiPefName Read Only 236 cfglpmiPeflndex Read Write 236 cfglpmiPefAction Read Write 236 cfglpmiPefEnable Read Write 236 cfglpmiPet 2 237 cfglpmiPetIndex Read
76. C Legal Values 10 65535 Default 443 F NOTE For CMC the following port numbers are reserved and cannot be used 21 68 69 123 161 546 801 4096 5988 5989 6900 9000 60106 cfgRacTunelpRangeEnable Read Write Description Enables or disables the IPv4 Address Range validation feature of iDRAC6 or CMC Legal Values 1 TRUE 0 FALSE Default 0 cfgRacTunelpRangeAddr Read Write Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1 s in the range mask property cfgRacTuneIpRangeMask For CMC a login from the incoming IP address is allowed only if the following are identical cfgRacTunelpRangeMask bit wise and with incoming IP address cfgRacTunelpRanbeMask bit wise and with cfgRacTunelpRangeAddr Legal Values An IPv4 address formatted string for example 192 168 0 44 Default 192 168 1 1 iDRAC6 and CMC Property Database Group and Object Descriptions 191 cfgRacTunelpRangeMask Read Write Description Standard IP mask values with left justified bits For example 255 255 255 0 For CMC a login from the incoming IP address is allowed only if both of the following are identical cfgRacTunelpRangeMask bit wise and with incoming IP address cfgRacTunelpRanbeMask bit wise and with cfgRacTunelpRangeAddr Legal Values An IPv4 address formatted string for example 255 255 255 0 Standard IP mask values with left justified bits Default 255 255 255 0
77. DM Subcommand Details lt Fan Request gt N A N A N A 69 12 SLOT 12 N A N A Not Present N A 13 SLOT 13 N A N A Not Present N A 14 SLOT 14 PowerEdgeM600 ON Present 33 15 SLOT 15 N A N A Not Present N A 16 SLOT 16 N A Extension N A N A 8 Switch Module Fan Request Table lt Slot gt lt Server lt Blade Type gt lt Power lt Presence gt lt Fan Name gt State gt Request gt 1 SLOT 01 PowerEdgeM600 ON Present 33 2 SLOT 02 PowerEdgeM905 ON Present 35 3 SLOT 03 PowerEdgeM710 ON Present 44 4 SLOT 04 PowerEdgeM610 ON Present 46 5 SLOT 05 PowerEdgeM610 ON Present 46 6 SLOT 06 N A N A Not Present N A 7 SLOT 07 PowerEdgeM605 ON Present 100 fwupdate 8 SLOT 08 PowerEdgeM710 ON Present 44 9 SLOT 09 A N A ot Present N A 10 SLOT 10 A Extension N A N A 2 1 SLOT 11 A Extension N A N A 3 12 SLOT 12 A N A ot Present N A 3 SLOT 13 A N A ot Present N A 4 SLOT 14 PowerEdgeM600 ON Present 33 5 SLOT 15 A N A ot Present N A 6 SLOT 16 A Extension N A N A 8 70 RACADM Subcommand Details Switch Module Fan Request Table lt IO lt Name gt lt Type gt lt Presence gt lt Fan Name gt Request gt Switch 1 Dell Ethernet Pass Gigabit Present 30 Through Ethernet Switch 2 Dell PowerConnect Gigabit Present 30 M6220 Ethernet Switch 3 N A None Not Present N A Switch 4 N A None Not Present N A Switch 5 N A None Not Present N A Switch 6 N A None Not Present N A F
78. Default 100 cfgChassisRedundancyPolicy Read Write Description Sets the redundancy policy of the chassis Legal Values 0 no redundancy 1 AC redundancy 2 power supply redundancy 0 Default no redundancy cfgChassisDynamicPSUEngagementEnable Read Write Description Enables or disables dynamic engagement Legal Values 0 disabled 1 enabled Default 0 disabled 228 iDRAC6 and CMC Property Database Group and Object Descriptions cfgChassisAllow110VACOperation Read Write Description Enables or disables normal chassis power allocations when any power supply unit is connected to 110V AC service If disabled and 110V power supplies are detected all subsequent server power allocation requests are denied In this mode additional servers cannot be powered on regardless of server priority Legal Values 0 disabled 1 enabled Default 0 disabled cfgChassisMaxPowerConservationMode Read Write Description Enables or disables max power conservation mode When enabled all servers are immediately reduced to their minimum power levels and all subsequent server power allocation requests are denied In this mode performance of powered on servers may be degraded and additional servers cannot be powered on regardless of server priority Legal Values 0 disabled 1 enabled Default 0 disabled cfgChassisPerformanceOverRedundancy Read Write Description Enables or disables server performance over power redund
79. Emulation Read Write 200 cfgVirMediaKeyEnable Read Write 200 cfgSDWriteProtect Read only 201 cfgLCDriveEnable Read Write 201 cfgServerlnfo 202 cfgServerlnfolndex Read only 202 cfgServerSlotNumber Read only 202 cfgServerServiceTag Read only 203 cfgServerName Read Write 203 cfgServerFW Readonly 203 cfgServerBIOS Read only 203 cfgServerBmcMacAddress Read only 204 cfgServerNic1MacAddress Read only 204 cfgServerNic2MacAddress Read only 204 cfgServerNic3MacAddress Read only 204 cfgServerNic4MacAddress Read only 205 cfgServerPriority Read Write 205 cfgServerNicEnable Read Write 205 cfgServerlIPMlOverLanEnable Read Write 205 Contents 11 cfgServerPowerBudgetAllocation Read only 206 cfgServerDNSRegisterIMC Read Write 206 cfgServerDNSIMCName Read Write 206 cfgServerRootPassword Write only 206 cfgServerFirstBootDevice Read Write 207 cfgServerBootOnce Read Write 207 cfgServerPowerConsumption Read only 208 cfgActiveDirectory 209 cfgADRacDomain Read Write 210 cfgADRacName Read Write 210 cfgADRootDomain 210 cfgADEnable Read Write 210 cfgADSCLEnable 211 cfgADSSOEnable Read W
80. Group and Object Descriptions 247 cfgServerPowerLastWeekMaxPowerTime Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the timestamp of maximum power value during the last week Legal Values A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week MM Month Date Date YYYY Year HH hour MM Minutes SS Seconds Default Maximum power value during the last week cfgServerPowerlnstHeadroom Read Only F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers Description Displays the difference between the available power and the current power consumption Legal Values A string of up to 32 characters Default Difference between the available power and the current power consumption 248 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerPeakHeadroom Read Only F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Displays the difference between the available power and the peak power consumption Legal Values A string of up to 32 characters Default Difference between the available power and the peak power consumption cfgServerActualAmperageConsumption Read Only F NOTE This object is applicable only for iDRAC6
81. IP address This property is only valid if efgNicUseDhep is set to 0 FALSE Legal Values String representing a valid subnet mask For example 255 255 255 0 Default 255 255 255 0 iDRAC6 and CMC Property Database Group and Object Descriptions 163 cfgNicGateway Read Write 4 NOTE This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 FALSE Description iDRAC6 or CMC gateway IPv4 address The gateway IPv4 address used for static assignment of the RAC IP address This property is only valid if cfgNicUseDhcp is set to 0 FALSE Legal Values String representing a valid gateway IPv4 address For example 192 168 0 1 Default 192 168 0 1 cfgNicUseDhcp Read Write Description Specifies whether DHCP is used to assign the iDRAC6 or CMC IPv4 address If this property is set to 1 TRUE then iDRAC6 or CMC IPv4 address subnet mask and gateway are assigned from the DHCP server on the network If this property is set to 0 FALSE the user can configure the cfgNiclpAddress cfgNicNetmask and cfgNicGateway properties Legal Values 1 TRUE 0 FALSE Default 0 cfgNicMacAddress Read Only Description The iDRAC6 or CMC NIC MAC address in the format dd dd dd dd dd dd where d is a hexadecimal digit in range 0 9 A F Legal Values String representing iDRAC6 or CMC NIC MAC address Default The current MAC address of iDRAC6 or CMC NIC For example 00 12 67 52 51 A3 164 iDRAC6 and CMC Proper
82. J J d J Rac cfgRaci cfgRacl Ge G G C C G GG GG GG neRemoteRacadm Enable 1 neHttpPort 80 neSshPort 22 neWebserverEnable 1l neHttpsPort 443 neTelnetPort 23 neIlpRangeEnable 0 neIpRangeAddr 192 168 1 1 neIpRangeMask 255 255 255 0 neIpBlkEnable 0 neIpBlkFailCount 5 neIpBlkFailWindow 60 neIpBlkPenaltyTime 300 TuneTimezoneOffset 18000 TuneDaylightOffset 3600 cfgRacTuneTimezoneOffset Read Only Description Legal Values Default Specifies the time zone offset in minutes from Greenwich Mean Time GMT Coordinated Universal Time UTC to use for the RAC Time Some United States are e 480 PST Pa common time zone offsets for time zones in the cific Standard Time e 420 MST Mountain Standard Time 360 CST C entral Standard Time e 300 EST Eastern Standard Time For CMC This object property is read only Specifies the difference in number of seconds from the UTC GMT This value is negative if the current time zone is west of Greenwich 720 7800 0 iDRAC6 and CMC Property Database Group and Object Descriptions 195 cfgRacTuneLocalServerVideo Read Write F NOTE This object property is applicable only to iDRAC6 Description Enables switches on or disables switches off the local server video Legal Values 1 TRUE Enables 0 FALSE Disables Default l cfgRacTuneLocalCo
83. LdapRoleGroup group cfgLdapRoleGroupIndex Read Only F NOTE This object is applicable only for iDRAC6 Description This is the index value of the Role Group Object Legal Values An integer between and 5 Default lt instance gt cfgLdapRoleGroupDN Read Write Description This is the Domain Name of the group in this index For CMC configure the LDAP distinguished name DN for the role group instance Legal Values String Maximum length 1024 Default None Example racadm getconfig g cfgLDAPRoleGroup o cfgLDAPRoleGroupDN i 1 cn everyone ou groups dc openldap dc com 222 iDRAC6 and CMC Property Database Group and Object Descriptions cfgLdapRoleGroupPrivilege Read Write Description A bit mask defining the privileges associated with this particular group Legal Values 2 3 4 and 5 where 2 User 3 Admin 4 Operator 15 No Access Default 15 Example racadm getconfig g cfgLDAPRoleGroup o cfgLDAPRoleGroupPrivilege i 1 2 cfgStandardSchema This group contains parameters to configure the Active Directory standard schema settings F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option The followi
84. MC Property Database Group and Object Descriptions cfgSmartCard This group is applicable only for iDRAC6 and specifies properties used to support access to iDRAC6 using a smart card The following sections provides information about the objects in the cfgSmartCard group cfgSmartCardLogonEnable Read Write Description Enables disables or enables with Remote RACADM support for access to iDRAC6 using a smart card NOTE Enabling with remote RACADM is only applicable for iDRAC6 on Rack and Tower Servers Legal Values 0 Disabled 1 Enabled 2 Enabled with Remote RACADM This is not applicable for iDRAC6 Enterprise on Blade Servers Default 0 cfgSmartCardCRLEnable Read Write F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers Description Enables or disables the Certificate Revocation List CRL Legal Values 1 TRUE 0 FALSE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 271 cfgNetTuning This group enables users to configure the advanced network interface parameters for the RAC NIC or CMC When configured the updated settings may take up to a minute to become active The following sections provides information about the objects in the cfgNetTuning group F NOTE The cfgNetTuning object group is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers A CA
85. NOTE This object is applicable only for CMC K NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property you must have Chassis Configuration Administrator privilege F NOTE You can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option This group is used to display information for and configure the iKVM cfgKVMAccessToCMCEnable Description Enables or disables the Dell CMC Console access on the iKVM Legal Values 1 enable 0 disable Default None 252 iDRAC6 and CMC Property Database Group and Object Descriptions cfgKVMFrontPanelEnable Description Enables or disables front panel access on the iKVM Legal Values 1 enable 0 disable Default None Example racadm getconfig g cfgKVMInfo cf gKVMAccessToCMCEnable 1 cfgKVMFrontPanelEnable 1 cfgAlerting F NOTE This object is applicable only for CMC F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property you must have Chassis Configuration Administrator privilege This group is used to enables or disable SNMP event trap alerting and set the event filter cfgAlertingEnable Description Enables or disables event traps on the CMC Legal Values 1 true 0 false Default None cfgAlertingFilterMask Description Sets the event filter Legal Values Hex values 0x0 0x01 fff fff Default
86. Only 237 cfglpmiPetAlertDestlpAddr Read Write 237 cfglpmiPetAlertEnable Read Write 237 cfgUserDomain 4 238 cfgUserDomainIndex Read Only 238 cfgUserDomainName Read Only 238 cfgServerPower 0 238 cfgServerPowerStatus Read Only 238 cfgServerPowerAllocation Read Only 239 cfgServerActualPowerConsumption Read Only 239 cfgServerPowerCapEnable Read Only 239 cfgServerMinPowerCapacity Read Only 240 cfgServerMaxPowerCapacity Read Only 240 cfgServerPeakPowerConsumption Read Only 240 Contents 15 cfgServerPeakPowerConsumptionTimestamp Read Only 00 240 cfgServerPowerConsumptionClear Write Only 241 cfgServerPowerCapWatts Read Write 241 cfgServerPowerCapBtuhr Read Write 241 cfgServerPowerCapPercent Read Write 241 cfgServerPowerLastMinAvg Read Only 242 cfgServerPowerLastHourAvg Read Only 242 cfgServerPowerLastDayAvg Read Only 242 cfgServerPowerLastWeekAvg Read Only 242 cfgServerPowerLastHourMinPower Read Only 243 cfgServerPowerLastHourMinTime Read Only 243 cfgServerPowerLastHourMaxPower Read Only 243 cfgServerPowerLastHourMaxTime Read Only 244 cfgServerPowerLastDayMinPower Read Only 244 cfgServerPowerLastDayMinPowerTime Read Only sis EE es ore kus Q ee OE sa 245 cfgServerPowerLastDayMaxPower Read Only 245
87. Operator 4 Administrator Default 4 cfglpmiSerialFlowControl Read Write Description Specifies the flow control setting for the IPMI serial port Legal Values 0 None 1 CTS RTS Default 1 268 iDRAC6 and CMC Property Database Group and Object Descriptions cfglpmiSerialHandshakeControl Read Write Description Enables or disables the PMI terminal mode handshake control Legal Values 0 FALSE 1 TRUE Default l cfglpmiSerialLineEdit Read Write Description Enables or disables line editing on the IPMI serial interface Legal Values 0 FALSE 1 TRUE Default 1 cfglpmiSerialEchoControl Read Write Description Enables or disables echo control on the IPMI serial interface Legal Values 0 FALSE 1 TRUE Default l cfglpmiSerialDeleteControl Read Write Description Enables or disables delete control on the IPMI serial interface Legal Values 0 FALSE 1 TRUE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 269 270 cfglpmiSerialNewLineSequence Read Write Description Legal Values Default Specifies the newline sequence specification for the IPMI serial interface 0 None 1 CR LF 2 NULL 3 lt CR gt 4 lt LF CR gt 5 lt LF gt 1 cfglpmiSeriallnputNewLineSequence Read Write Description Legal Values Default Specifies the input newline sequence specification for the IPMI serial interface 1 CR LF 2 NULL l iDRAC6 and C
88. RAC configuration change is required to use this external management network VLAN Legal Values 1 TRUE 0 FALSE Default 0 Example racadm config g cfgLanNetworking o cfgNicVLanEnable 1 racadm config g cfgLanNetworking o cfgNicVLanEnable 0 158 iDRAC6 and CMC Property Database Group and Object Descriptions cfgNicVLanld Read Write Description Specifies the VLAN ID for the network VLAN configuration in CMC for iDRACE Enterprise on Blade Servers This property is only valid if efgNicVLanEnable is set to 1 enabled Legal Values 1 4000 and 4021 4094 Default l Example racadm config g cfgLanNetworking o cfgNicVlanID 1 cfgNicVLanPriority Read Write Description Specifies the VLAN Priority for the network VLAN configuration in CMC for iDRAC6 Enterprise on Blade Servers This property is only valid if efgNicVLanEnable is set to 1 enabled Legal Values 0 7 Default 0 Example racadm config g cfgLanNetworking o cfgNicVLanPriority 7 cfgDNSDomainNameFromDHCP Read Write Description Specifies that iDRAC or CMC DNS domain name should be assigned from the network DHCP server Legal Values 1 TRUE 0 FALSE Default 0 For CMC this property is used only if cfgNicUseDhcp is set to 1 true or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1 true The CMC can obtain its DNS domain name from either a DHCP or DHCPv6 server if all of the following properties are set to 1 true cf
89. RACADM Command Line Reference Guide for IDRAG6 1 95 IDRAC6 3 5 and CMC 3 2 Notes and Cautions F NOTE A NOTE indicates important information that helps you make better use of your computer N CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed Information in this publication is subject to change without notice 2013 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo OpenManage and PowerEdge are trademarks of Dell Inc Microsoft Windows Windows Server and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries UNIX is aregistered trademark of The Open Groupin the United States and other countries Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own 2013 03 Contents 1 Introduction 23 Supported RACADM Interfaces 23 RACADM Syntax Usage 24 LocalRACADM 24 SSH TelnetRACADM 24 Remote RACADM 24 RACADM Command Options
90. RUE use DNS to look up GCS Default 0 cfgADGcRootDomain Read Write K NOTE This object is applicable only to iDRAC6 Description The name of the Active Directory root domain used for DNS look up to locate Global Catalog servers Legal Values String Maximum length 254 Default Null cfgLDAP F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option 216 iDRAC6 and CMC Property Database Group and Object Descriptions This group allows you to configure settings related to the Lightweight Directory Access Protocol LDAP The following sections provides information about the objects in the cfgLDAP group cfgLdapEnable Read Write Description Turns LDAP service on or off If this property is disabled local CMC authentication is used for user logins Legal Values 1 TRUE Enable LDAP Services 0 FALSE Disable LDAP Services Default 0 F NOTE For CMC enabling this option turns off cfgADEnable cfgLdapServer Read Write Description Configures the address of the LDAP Server IPv4 and IPv6 are supported Legal Values String For iDRAC6 Maximum length 1024 For CMC Maximum length 254 Default Null F NOTE You can specify mult
91. Read Write Description Retrieves the IPv4 address for DNS server 2 This parameter is only valid if cfg DNSServersFromDHCP is set to 0 FALSE NOTE cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses Legal Values String representing a valid IPv4 address For example 192 168 0 20 Default 0 0 0 0 162 iDRAC6 and CMC Property Database Group and Object Descriptions cfgNicEnable Read Write Description Enables or disables iDRAC6 or CMC network interface controller If the NIC is disabled the remote network interfaces to iDRAC6 or CMC are no longer accessible and iDRAC6 or CMC are only available through the local or serial RACADM interface Legal Values 1 TRUE 0 FALSE Default l cfgNiclpAddress Read Write F NOTE This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 FALSE Description Specifies the static IPv4 address to be assigned to the RAC or CMC This property is only valid if cfgNicUseDhcp is set to 0 FALSE Legal Values String representing a valid IPv4 address For example 192 168 0 20 Default For iDRAC6 on Rack and Tower Servers 192 168 0 120 For iDRAC6 Enterprise on Blade Servers 192 168 0 n where n is 120 plus the server slot number For CMC 192 168 0 120 cfgNicNetmask Read Write F NOTE This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 FALSE Description The subnet mask used for iDRAC6 or CMC
92. Read only F NOTE This object is applicable only to CMC Description Displays the current power allocation for the server Legal Values enable 0 disable Default None cfgServerDNSRegisterIMC Read Write F NOTE This object is applicable only to CMC Description Enables or disables DNS name registration for the Integrated Management Controller iDRAC Legal Values enable 0 disable Default None cfgServerDNSIMCName Read Write F NOTE This object is applicable only to CMC Description Displays the DNS domain name for the integrated Remote Access Controller iDRAC Legal Values None Default None cfgServerRootPassword Write only F NOTE This object is applicable only to CMC Description Displays the password for iDRAC as a series of asterisks It cannot be seen or displayed after this property is written Legal Values None Default None 206 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerFirstBootDevice Read Write F NOTE For CMC this object is Write only F NOTE For a vFlash Partition to be configured as First Boot Device it has to be attached first When a detached non existent VFlash partition or a non standard boot device is configured as first boot device the following error message is displayed Invalid object value Description Legal Values Default Sets or displays the first boot device For iIDRAC6 you can also set a vFlash parti
93. RedirDisable 106 netstat 107 ping 107 108 racdump 109 racreset 112 racresetcfg 113 serveraction 114 setassettag 115 setchassisname 116 setflexaddr 117 setled 118 setniccfg 120 setractime 121 setslotname 123 setsysinfo 124 sslcertupload 128 133 sslcertview 130 Index sslesrgen 132 sslresetcfg 134 testemail 135 testfeature 136 testtrap 139 traceroute 140 traceroute6 141 usercertupload 141 userertview 143 vmdisconnect 148 vmkey 148 S slot names setting with RACADM 123 SNMP community string 234 sslcertdownload 127 U usercertupload 141
94. Redundant or Non Redundant of mode the CMC Synopsis racadm getredundancymode 88 RACADM Subcommand Details Example racadm getredundancymode Redundant getsel F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description getsel The getsel subcommand display all sensor event log entries in the DRAC Synopsis racadm getsel i A racadm getsel s lt start gt c lt count gt A o R more Hi S F NOTE If no arguments are specified the entire log is displayed The following getsel options without the i option are used to read entries Table 2 21 describes the getsel subcommand options Table 2 21 getsel Subcommand Options Option Description A Specifies output with no display headers or labels c Provides the number of records to be displayed 0 Displays each entry in the SEL in a single line s Specifies the starting record used for the display E Displays RAW SEL data with the other data for each entry R Displays only RAW SEL data for each entry i Displays the number of entries in the SEL more Displays one screen at a time and prompts the user to continue similar to the UNIX more command RACADM Subcommand Details 89 Output The default output display shows the record number timestamp severity and description For example Record ils Date Time 11 16 2005 22 40 4
95. UTION Use extra precaution when modifying properties in this group Inappropriate modification of the properties in this group can result in your RAC NIC become inoperable cfgNetTuningNicSpeed Description Specifies the speed for the CMC NIC This property is used only if cfgNetTuningNicAutoNeg is set to 0 disabled Legal Values 10 or 100 Default 100 cfgNetTuningNicAutoneg Read Write Description Enables autonegotiation of physical link speed and duplex If enabled autonegotiation takes priority over values set in the cfeNetluningNic100MB and cfgNetTuningNicFullDuplex objects Legal Values 1 TRUE 0 FALSE Default l Example racadm getconfig g cfgNetTuning cfgNetTuningNicSpeed 100 cfgNetTuningNicFullDuplex 1 cfgNetTuningNicMtu 1500 cfgNetTuningNicAutoneg 1 272 iDRAC6 and CMC Property Database Group and Object Descriptions cfgNetTuningNic100MB Read Write Description Specifies the speed to use for the RAC NIC This property is not used if the cfgNetTuningNicAutoNeg is set to 1 enabled Legal Values 0 10 MBit 1 100 MBit Default l cfgNetTuningNicFullDuplex Read Write Description Specifies the duplex setting for the RAC or CMC NIC This property is used only if the cfgNetTuningNicAutoNeg is set to 0 disabled Legal Values 0 Half Duplex 1 Full Duplex Default l cfgNetTuningNicMtu Read Write Description The size in bytes of the maximum transmission unit used by iDRAC6 or CMC NIC
96. able 2 16 describes the getled subcommand options Table 2 16 getled Subcommand Options Option Description m lt module gt Specifies the module whose LED settings you want to view lt module gt can be one of the following server n where n 1 16 switch n where n 1 6 chassis cmc active Examples racadm getled m server 10 lt module gt lt LED state gt server 10 Blinking racadm getled m chassis lt module gt lt LED state gt server 10 Not blinking racadm getled m server l lt module gt lt LED state gt server 1 ON RACADM Subcommand Details 13 racadm getled m server 9 lt module gt lt LED state gt server 9 Extension 1 getmacaddress F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getmacaddress Displays the MAC WWN addresses for all modules or for a specified module Synopsis racadm getmacaddress m lt module gt t iscsi x racadm getmacaddress a Table 2 17 describes the getmacaddress subcommand options Table 2 17 getmacaddress Subcommand Options Option Description m lt module gt Specifies the module whose MAC address you want to view lt module gt may be one of the following chassis server n where n 1 16 switch n where n 1 6 t Displays the iSCSI MAC addresses for all servers or the specified server if used
97. able is set to 1 enabled For iDRAC6 String from 0 to 511 characters For CMC Valid hostname or IPv4 or IPv6 address lt blank gt cfgRhostsSyslogServer2 Read Write Description Legal Values Default Specifies the second of three possible remote syslog servers to store the RAC and SEL logs This property is only valid if cfgRhostsSyslogEnable is set to 1 enabled For iDRAC6 String from 0 to 511 characters For CMC Valid hostname or IPv4 or IPv6 address lt blank gt cfgRhostsSyslogServer3 Read Write Description Legal Values Default Specifies the third of three possible remote syslog servers to store the RAC and SEL logs This property is only valid if cfgRhostsSyslogEnable is set to 1 enabled For iDRAC6 String from 0 to 511 characters For CMC Valid hostname or IPv4 or IPv6 address lt blank gt iDRAC6 and CMC Property Database Group and Object Descriptions 169 cfgRhostsSyslogPowerLoggingEnabled F NOTE This object is applicable only for CMC Description Enables or disables power consumption logging to remote syslog servers Legal Values enabled 0 disabled Default 0 F NOTE Remote syslog must be enabled and one or more remote syslog servers configured for power consumption to be logged cfgRhostsSyslogPowerLogginglnterval F NOTE This object is applicable only for CMC Description Specifies the power consumption collection logging interval Legal Values 1 1440 m
98. an event is triggered on the managed server Legal Values A string representing a valid IPv4 address For example 192 168 0 67 Default 0 0 0 0 cfglpmiPetAlertEnable Read Write Description Enables or disables a specific trap Legal Values 1 TRUE 0 FALSE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 231 cfgUserDomain This group is applicable only for iDRAC6 and is used to configure the Active Directory user domain names A maximum of 40 domain names can be configured at any given time The following sections provides information about the objects in the cfgUserDomain group cfgUserDomainIndex Read Only Description Represents a specific domain Legal Values 1 40 Default The index value cfgUserDomainName Read Only Description Specifies the Active Directory user domain name Legal Values A string of up to 255 ASCII characters Default lt blank gt cfgServerPower This group provides several power management features The following sections provides information about the objects in the cfgServerPower group cfgServerPowerStatus Read Only F NOTE This object is applicable only for iDRAC6 Description Represents the server power state either ON or OFF Legal Values 1 ON 0 OFF Default 0 238 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerAllocation Read Only F NOTE This object is applicable only for iDRAC6 on Rack and T
99. ancy When enabled this option favors server performance and server powerup over maintaining power redundancy When disabled the system favors power redundancy over server performance When disabled then if the power supplies in the chassis do not provide sufficient power both for redundancy as well as full performance then some servers may not be granted sufficient power for full performance or may not be powered on in order to maintain redundancy Legal Values 0 disabled 1 enabled Default 1 enabled iDRAC6 and CMC Property Database Group and Object Descriptions 229 cfgChassisInMaxPowerCapacity Read Only Indicates the total chassis power budget in watts available for chassis operation cfgChassisInRedundancyReserve Read Only Indicates the amount of redundant power in watts in reserve that can be utilized in the event of an AC grid or PSU failure This value is 0 if the Redundancy Policy is set to 0 no redundancy cfgChassisInPowerServerAllocation Read Only Indicates in watts the cumulative power allocated to servers There is no default as this parameter is very specific to the particular customer configuration cfgChassisInfrastructurelnPowerAllocation Read Only Indicates the estimated cumulative DC output power consumption in watts determined from a field replaceable unit FRU on the hardware modules in the chassis cfgChassisTotallnPowerAvailable Read Only Indicates the amount of po
100. and cannot be used 21 68 69 123 161 546 801 4096 5988 5989 6900 9000 60106 iDRAC6 and CMC Property Database Group and Object Descriptions 193 cfgRacTuneConRedirEnable Read Write F NOTE This object property is applicable only to iDRAC6 Description Enables or disables Virtual Console Legal Values 1 TRUE 0 FALSE Default l cfgRacTuneConRedirEncryptEnable Read Write F NOTE This object property is applicable only to iDRAC6 Description Encrypts the video in a Virtual Console session Legal Values 1 TRUE 0 FALSE Default 1 cfgRacTuneAsrEnable Read Write F NOTE This object property is applicable only to iDRAC6 F NOTE This object requires an iDRAC6 reset before it becomes active Description Enables or disables iDRAC6 last crash screen capture feature Legal Values 1 TRUE 0 FALSE Default 0 cfgRacTuneDaylightOffset Read Only Description Specifies the daylight savings offset in minutes to use for the RAC Time This value is 0 if the time zone is not a Daylight Saving time Zone Legal Values 0 60 Default 0 194 iDRAC6 and CMC Property Database Group and Object Descriptions Example racadm getconfig g cfgRacTuning m server lt n gt o lt object name gt lt object value gt cfg cfg cfg cfg cfg CEG cfg cfg cfg cfg cfg cfg cfg Raci Raci Raci Raci Raci Raci Raci Raci Raci Raci Raci Raci J J J i J I jJ J J
101. apacity 0 W Input Redundancy Reserve 0 W Input Power Allocated to Servers 0 W Input Power Allocated to Chassis Infrastructure 51W Total Input Power Available for Allocation 0 W Standby Input Power Capacity 0 W getraclog F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description getraclog The getraclog i command displays all the RAC log entries in the DRAC Synopsis racadm getraclog i racadm getraclog A o c count s start record more Table 2 19 lists the options that allow the getraclog command to read entries Table 2 19 getraclog Subcommand Options Option Description A Displays the output with no headers or labels c Provides the maximum count of entries to be returned 86 RACADM Subcommand Details Table 2 19 getraclog Subcommand Options continued Option Description more Displays one screen at a time and prompts the user to continue similar to the UNIX more command 0 Displays the output in a single line Specifies the starting record used for the display NOTE If no options are provided the entire log is displayed Output The default output display shows the record number time stamp source and description The timestamp begins at midnight January 1 and increases until the system boots After the system boots the system s timestamp is used F NOTE For iDRAC6 Enterp
102. ate u m iominf 4 m iominf 5 m iominf 6 Query the current status of all firmware targets to be updated racadm fwupdate s m all RACADM Subcommand Details 59 Query the current status of the firmware update process for a particular module racadm fwupdate s m lt module gt Cancel a firmware update in progress racadm fwupdate c Upload a firmware image from the client and start the firmware update racadm fwupdate p u d firmimg cmc F NOTE The fwupdate command generates an error when used on the extension slot of a multi slot server F NOTE Image path length for Remote RACADM is 256 characters and for local RACADM it is 64 characters Output Displays a message indicating the operation that is being performed Examples racadm fwupdate g u a 143 166 154 143 q lt path gt In this example the g option tells the firmware to download the firmware update file from a location specified by the d option on the TF TP server at a specific IP address specified by the a option After the image file is downloaded from the TFTP server the update process begins When completed iDRAC6 is reset racadm fwupdate s This option reads the current status of the firmware update F NOTE Firmware update from local racadm using p u d options is not supported on linux 0S F NOTE For CMC these commands specifically apply to an active CMC update 60 RACADM Subcommand Deta
103. atelnterval Read Write Description Specifies the typical amount of time that iDRAC6 waits before transmitting a partial SOL character data packet This value is 1 based 5ms increments Legal Values 1 255 Default 10 cfglpmiSolSendThreshold Read Write Description The SOL threshold limit value Specifies the maximum number of bytes to buffer before sending an SOL data packet Legal Values 1 255 Default 255 cfglpmiLan This group is applicable only for iDRAC6 and is used to configure the IPMI over LAN capabilities of the system The following sections provides information about the objects in the cfgIpmiLan group cfglpmiLanEnable Read Write Description Enables or disables the IPMI over LAN interface Legal Values 1 TRUE 0 FALSE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 233 cfglpmiLanPrivLimit Read Write Description Specifies the maximum privilege level allowed for IPMI over LAN access Legal Values 2 User 3 Operator 4 Administrator Default 4 cfglpmiLanAlertEnable Read Write Description Enables or disables global e mail alerting This property overrides all individual e mail alerting enable disable properties Legal Values 1 TRUE 0 FALSE Default 0 cfglpmiEncryptionKey Read Write Description The IPMI encryption key Legal Values A string of hexadecimal digits from 0 to 40 characters with no spaces Only an even amount of digits is allowed D
104. ble values of x F NOTE The b c and options are not available for CMC modules F NOTE The I option requires that the Lifecycle Controller service is enabled on the servers For version information see the RACADM Readme available on the Dell Support website at dell com support manuals Example racadm getversion m server 15 lt server gt lt iDRAC version lt model name gt lt Gen gt lt Updatable gt server 15 2 00 Build 10 PowerEdgeM605 iDRAC N racadm getversion lt Server gt lt iDRAC Version gt lt Blade Type gt lt Gen gt lt Updatable gt server 2 1 50 PowerEdgeM600 iDRAC Y server 3 2 10 PowerEdgeM610 iDRAC6 Y server 4 1 50 PowerEdgeM605 iDRAC r lt CMC gt lt CMC Version gt lt Updatable gt cmc 1 2 10 X06 200906 ii 080825 102 RACADM Subcommand Details racadm getversion c lt Server gt lt CPLD Version gt lt Blade Type gt server 1 PowerEdgeM600 server 2 PowerEdgeM805 server 5 1 0 0 PowerEdgeM710 racadm getversion b lt Server gt lt BIOS Version gt lt Blade Type gt server 1 2 0 0 PowerEdgeM605 server 2 1 1 0 PowerEdgeM805 server 5 134 20 PowerEdgeM710 racadm getversion l m server 1 lt Server gt lt Component gt lt Version gt lt Install Date gt server 1 BIOS Le Pad 2010 11 22 ADRAC 3 20 2010 11 22 USC 1 5 0 667 2011 02 05 Diagnostics 5144A0 2011 02 07 OS Drivers 6 30 15 2010 11 22 Broadcom 5709
105. cfgServerPowerLastDayMaxPowerTime Read Only 00 246 cfgServerPowerLastWeekMinPower Read Only 246 cfgServerPowerLastWeekMinPowerTime Read Only 0 247 cfgServerPowerLastWeekMaxPower Read Only 247 cfgServerPowerLastWeekMaxPowerTime Read Only u T ai pk 3 AUS 248 cfgServerPowerlnstHeadroom Read Only 248 cfgServerPowerPeakHeadroom Read Only 249 cfgServerActualAmperageConsumption ReadOnly 249 cfgServerPeakAmperage Read Only 249 cfgServerPeakAmperagelimeStamp Read Only 250 cfgServerCumulativePowerConsumption Read Only 0 250 16 Contents cfgServerCumulativePowerConsumptionTimeStamp Read Only 20 251 cfgServerCumulativePowerClear Write Only 251 cfgServerPeakPowerClear Write Only 251 cfgServerPowerPCleAllocation Read Write 252 cfgKVMInfo 252 cfgkVMAccessToCMCEnable 252 cfgKVMFrontPanelEnable 253 cfgAlerting 0 000000 5 253 cfgAlertingEnable 253 cfgAlertingFilterMask 253 cfgAlertingSourceEmailName 254 cfgServerPowerSupply 254 cfgServerPowerSupplyIndex 254 cfgServerPowerSupplyMaxInputPower Read Only 20 255 cfgServerPowerSupplyMaxOutputPower Read Only 2 255 cfgServerPowerSupplyOnlineStatus Read Only
106. ciated object and objects are organized by object group The IDs for the groups and objects that the property database supports are listed in this section for iDRAC6 Enterprise on Blade Servers iDRAC6 Enterprise or Express on Rack and Tower Servers and CMC Use the group and object IDs with the RACADM subcommands to configure iDRAC6 and CMC Table 3 1 provides an overview of the object groups applicable for iDRAC6 Enterprise on Blade Servers iDRAC6 on Rack and Tower Servers and CMC A CAUTION Racadm sets the value of objects without performing any functional validation on them For example RACADM allows you to set the Certificate Validation object to 1 with the Active Directory object set to 0 even though Certificate Validation can happen only if Active Directory is enabled Similarly the cfgADSSOEnable object can be set to 0 or 1 even if the cfgADEnable object is 0 but it takes effect only if Active Directory is enabled All string values are limited to displayable ASCII characters except where otherwise noted iDRAC6 and CMC Property Database Group and Object Descriptions 151 Displayable Characters Displayable characters include the following set abcdefghijklmnopgrstuvwxwz ABCDEFGHIJKLMNOPORSTUVWXYZ 0123456789 amp _ 1N lt gt Table 3 1 lists the supported object groups Table 3 1 Supported Object Groups Subcommand iDRAC6 on Blade
107. command you must have Configure iDRAC permission Subcommand Description sslcertview Displays the SSL server or CA certificate that exists on IDRAC6 Synopsis racadm sslcertview t lt type gt A Table 2 41 describes the sslcertview subcommand options F NOTE The current release does not support type 3 and 4 t options Table 2 41 sslcertview Subcommand Options Option Description t Specifies the type of certificate to view either the CA certificate or server certificate 1 server certificate 2 CA certificate for Directory Service 3 KMS public certificate 4 KMC public certificate NOTE The current release does not support type 3 and 4 A Prevents printing headers labels Sample Output racadm sslcertview t 1 Serial Number 00 Subject Information Country Code CC US State S Texas Locality L Round Rock RACADM Subcommand Details 131 Organization O DE ll Irne Organizational Unit OU Remote Access Group Common Name CN iDRAC6 default certificate Issuer Information Country Code CC US State S Texas Locality L Round Rock Organization O Dell Inc Organizational Unit OU Remote Access Group Common Name CN iDRAC6 default certificate Valid From Jul 8 16 21 56 2005 GMT Valid To Jul 7 16 21 56 2010 GMT racadm sslcertview t 1 A 00 US Texas Round Rock Dell Inc Remote Access Group iDRAC6
108. cription lt action gt Specifies the action The options for the lt action gt string are powerdown Powers down the managed system powerup Powers up the managed system powercycle Issues a power cycle operation on the managed system This action is similar to pressing the power button on the system s front panel to power down and then power up the system powerstatus Displays the current power status of the server ON or OFF hardreset Performs a reset reboot operation on the managed system Output The serveraction subcommand displays an error message if the requested operation could not be performed or a success message if the operation is completed successfully RACADM Subcommand Details 115 setassettag F NOTE To use this subcommand you must have Administrator privilege Subcommand Description setassettag Sets the N byte ASCII asset tag for the chassis Synopsis racadm setassettag m chassis lt asset tag gt 116 RACADM Subcommand Details Table 2 31 describes the setassettag subcommand option Table 2 31 setassettag Subcommand Options Option Command m lt module gt Specifies the module whose asset tag you want to set Legal value chassis NOTE Because there is only one legal value you can obtain the same output if you do not include this option NOTE lt assettag gt is a maximum of 64 non extended ASCII characters Example Input
109. cription s Displays the status of active features d Deactivates feature specified in c option a Activates ExtendedStorage feature 1 Configures ExtendedStorage feature for standalone use 2 Configures ExtendedStorage feature for redundant use 50 RACADM Subcommand Details Table 2 6 feature Subcommand Options continued Option Description T Reformats damaged unformatted ExtendedStorage media CAUTION Using the r switch deactivates the ExtendedStorage feature if active reformats the SD media in the active CMC cardslot and may reboot the active CMC lt featurename gt must be one of the following flexaddress with d flexaddressplus with d ExtendedStorage with a d 1 2 or r Example racadm featur d c flexaddress The feature FlexAddress is deactivated on the chassis successfully racadm feature s Featu r Name FlexAddress Date time Activated 26 Apr 2010 10 16 48 Featu TESTO Featu re installed from SD card serial number 123456789012345678 r Name FlexAddressPlus Date time Activated 26 Apr 2010 10 16 48 Featu TESTO re installed from SD card serial number 123456789012345678 Featu r name ExtendedStorage for redundant use Date time Activated 06 May 2010 07 42 20 Featu TESTO re installed from SD card serial number 123456789012345678 RACADM Subcommand D
110. curity port restrictions The following sections provides information about the objects in the cfgRacTuning group cfgRacTuneConRedirPort Read Write F NOTE This object is applicable only to iDRAC6 Description Specifies the port to be used for keyboard mouse video and Virtual Media traffic to iDRAC6 Legal Values 1025 65535 Default 5900 iDRAC6 and CMC Property Database Group and Object Descriptions 189 cfgRacTuneRemoteRacadmEnable Read Write Description Enables or disables the Remote RACADM interface in iDRAC or CMC Legal Values 1 TRUE 0 FALSE Default l cfgRacTuneCtrlEConfigDisable F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Enables or disables the ability to disable the ability of the local user to configure IDRAC from the BIOS POST option ROM Legal Values 1 TRUE 0 FALSE Default 0 cfgRacTuneHttpPort Read Write Description Specifies the port number to use for HTTP network communication with iDRAC6 or CMC Legal Values 10 65535 Default 80 F NOTE For CMC the following port numbers are reserved and cannot be used 21 68 69 123 161 546 801 4096 5988 5989 6900 9000 60106 190 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacTuneHttpsPort Read Write Description Specifies the port number to use for HTTPS network communication with iDRAC6 or CM
111. cy s cfgVFlashSD q s cfgVFlashPartition s s cfgLogging s s cfgKMSProfile s Supported Not supported idRaclnfo This group contains display parameters to provide information about the specifics of iDRAC6 or CMC being queried One instance of the group is allowed F NOTE For CMC use this object with the getconfig subcommand F NOTE To use this object for CMC you must have CMC Login User privilege The following sections provides information about the objects in the idRACInfo group idRacProductinfo Read Only Description A text string that identifies the product Legal Values A string of up to 63 ASCII characters Default for iDRAC Integrated Dell Remote Access Controller Default for CMC Chassis Management Controller 154 iDRAC6 and CMC Property Database Group and Object Descriptions idRacDescriptionlnfo Read Only Description A text description of the RAC type Legal Values A string of up to 255 ASCII characters Default This system component provides a complete set of remote management functions for Dell PowerEdge servers idRacVersionInfo Read Only Description String containing the current product firmware version Legal Values A string of up to 63 ASCII characters Default The current version number idRacBuildInfo Read Only Description String containing the current RAC firmware build version Legal Values A string of up to 16 ASCII characters Defa
112. d Details Delete The delete mode allows the user to delete a key specified by the user or all keys racadm sshpkauth i lt 2 to 16 gt d k lt 1 to 4 gt racadm sshpkauth i lt 2 to 16 gt d k all Table 2 38 describes the sshpkauth subcommand options Table 2 38 sshpkauth Subcommand Options Option Description i lt user index gt Index for the user lt user index gt must be between 2 to 16 on iDRAC6 k lt key index gt all Index to assign the PK key being uploaded all only works with the v or d options lt key index gt must be between 1 to 4 or all on iDRACO t lt PK Key Text gt Key text for the SSH Public key f lt filename gt File containing the key text to upload The f option is not supported on Telnet ssh serial RACADM v View the key text for the index provided d Delete the key for the index provided Examples Upload an invalid key to iDRAC6 User 2 in the first key space using a string racadm sshpkauth i 2 k 1 t This is invalid key Text ERROR Key text appears to be corrupt Upload a valid key to iDRAC6 User 2 in the first key space using a file racadm sshpkauth i 2 k 1 f pkkey key Key file successfully uploaded Get all keys for User 2 on iDRAC6 racadm sshpkauth v i 2 k all KKKKKKKKKKKKKKKKKKKKK User ID 2 KKKKKKKKKKKKKKKKKK Key ID 1 RACADM Subcommand Details 127 ssh rsa AAAAB3NzaClyc2EAAAABIWAAATEAzzyt k2npnKqVEXGXI
113. de last minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians For more information on IOM network settings see the Dell PowerConnect M6220 Switch Important Information document and the Dell PowerConnect 6220 Series Port Aggregator White Paper Updates are sometimes included with the system to describe changes to the system software and or documentation Always read the updates first because they often supersede information in other documents See the Safety and Regulatory information that is shipped with your system F NOTE Warranty information may be included within this document or as a separate document 32 Introduction RACADM Subcommand Details This section provides detailed descriptions of the RACADM subcommands including the syntax and valid entries Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands When using strings that contain special characters use the following guidelines Strings containing the following special characters must be quoted using single quotes or double quotes dollar sign double quote single quote back quote backslash tilde semicolon vertical bar left parentheses right parentheses amp ampersand gt greater than lt less than pound ASCII code 32 space
114. default certificate US Texas Round Rock Dell Inc Remote Access Group iDRAC6 default certificate Jul 8 16 21 56 2005 GMT Jul 7 16 21 56 2010 GMT 132 RACADM Subcommand Details sslcsrgen F NOTE To use this subcommand you must have Configure iDRAC permission Subcommand Description sslcsrgen Can be used to generate a CSR and download the file to the client s local file system The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRAC6 Synopsis racadm sslcsrgen g f lt filename gt racadm sslcsrgen s Table 2 42 describes the sslesrgen subcommand options F NOTE The f option is not supported for the serial Telnet ssh console Table 2 42 sslcsrgen Subcommand Options Option Description g Generates a new CSR S Returns the status of a CSR generation process generation in progress active or none f Specifies the filename of the location lt filename gt where the CSR is downloaded t Specifies the type of certificate to view either the CA certificate or server certificate 1 webserver CSR enables you to generate a CSR for the webcertificate server certificate 2 KMC certificate enables you to generate a CSR for the KMC certificate and a CA certificate for Directory Service NOTE The current release does not support type 2 F NOTE Ifthe f option is not specified the filename defau
115. ds Default 120 cfgADType Read Write Description Determines the schema type to use with Active Directory Legal Values 1 Enables Active Directory with the extended schema 2 Enables Active Directory with the standard schema Default 1 212 iDRAC6 and CMC Property Database Group and Object Descriptions cfgADSpecifyServerEnable F NOTE This object is applicable only to CMC Description Allows you to enable or disable and specify an LDAP server or a global catalog server Use cfgADDomainController or cfgADClobalCatalog to specify the IP address Legal Values enabled 0 disabled Default 0 cfgADGlobalCatalog F NOTE This object is applicable only to CMC Description Specifies the global catalog server from which you want the CMC to obtain user names Must be used with cfgADSpecifyServerEnable Legal Values Valid IP address or FODN Default None Example racadm getconfig g cfgActiveDirectory Enable 1 SCLEnable 0 cfgADSSOEnable 0 cfgADRacDomain cfgAD D D D cfgADRootDomain help D D D D D cfgA cfgADRacName cfgADRacAuthTimeout 300 cfgA cfgADSpecifyServerEnable 1 cfgADDomainController 192 168 1 1 cfgADGlobalCatalog 127 0 0 1 iDRAC6 and CMC Property Database Group and Object Descriptions 213 cfgADGlobalCatalog1 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the Global Catalog server for u
116. e v option displays additional details with the display of the properties and is used with the g option Output This subcommand generates error output upon encountering either of the following Invalid syntax group name object name index or other invalid database members RACADM CLI transport failures If errors are not encountered this subcommand displays the contents of the specified configuration Examples racadm getconfig g cfgLanNetworking Displays all of the configuration properties objects that are contained in the group cfgLanNetworking racadm getconfig f myrac cfg Saves all group configuration objects from iDRAC6 to myrac cfg RACADM Subcommand Details 63 racadm getconfig h Displays a list of the available configuration groups on iDRAC6 in an alphabetical order racadm getconfig u root Displays the configuration properties for the user named root racadm getconfig g cfgUserAdmin i 2 v Displays the user group instance at index 2 with verbose information for the property values getdcinfo F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getdcinfo Displays general VO module and daughter card configuration information F NOTE Fabric verification for server DCs is performed only when the chassis is powered on When the chassis is on standby power iDRACs on the server modules remain powered off and thu
117. e CMC registers its DNS name for its IPv4 and IPv6 addresses with the DNS server Legal Values 1 TRUE 0 FALSE Default 0 F NOTE For IPv6 only the DHCPv6 address or static address is registered Example racadm getconfig g cfgLanNetworking C C C FgNicVv fFgNicUseD an FgNicEnablesl FgNicIPv4Enablesl fgNicIpAddress 192 168 22 101 EgNicNetmask 255 255 255 0 FgNicGateway 192 168 22 101 hcp 1 cfgNicMacAddress 00 00 00 00 00 01 Enable 0 FgNicvl han FgNicvl Lan ID 1 Priority 0 FgDNSServersFromDHCP 1 FgDNSServer1 192 168 0 5 FgDNSServer2 192 168 0 6 fFgDNSRacName cmc frankly fgDNSDomainName fwad lab FgDNSDomainNameF romDHCP 1 fgDNSRegisterRac 1 iDRAC6 and CMC Property Database Group and Object Descriptions 161 cfgDNSServersFromDHCP Read Write Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network For CMC this property is used only if cfgNicUseDhep is set to 1 true Legal Values 1 TRUE 0 FALSE Default 0 cfgDNSServer1 Read Write Description Specifies the IPv4 address for DNS server 1 This property is only valid if efg DNSServersFromDHCP is set to 0 FALSE NOTE cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses Legal Values String representing a valid IPv4 address For example 192 168 0 20 Default 0 0 0 0 cfgDNSServer2
118. e Dell Chassis Management Controller User Guide for examples on using the connect subcommand RACADM Subcommand Details 45 coredump F NOTE This option is applicable only for iDRAC6 K NOTE To use this subcommand you must have Execute Debug Commands permission Subcommand Description coredump Displays detailed information related to any recent critical issues that have occurred with the RAC The coredump information can be used to diagnose these critical issues If available the coredump information is persistent across iDRAC6 power cycles and remains available until either of the following conditions occur The coredump information is cleared with the coredumpdelete subcommand Another critical condition occurs on the RAC In this case the coredump information is relative to the last critical error that occurred See the coredumpdelete subcommand for more information about clearing the coredump Synopsis racadm coredump 46 RACADM Subcommand Details coredumpdelete F NOTE This option is applicable only for iDRAC6 F NOTE To use this subcommand you must have Clear Logs or Execute Debug Commands permission Subcommand Description coredump Clears any currently resident coredump data stored in the RAC F NOTE If a coredumpdelete command is issued and a coredump is not currently stored in the RAC the command displays a success message This behavior is expected S
119. e forwarded from your system to a destination IPv6 address Synopsis racadm traceroute6 lt IPv6 address gt racadm traceroute fd01 1 traceroute to fd01 1 fd01 1 from fd01 3 30 hops max 16 byte packets 1 fdO1l 1 fd01 1 14 324 ms 0 26 ms 0 244 ms usercertupload K NOTE To use this subcommand you must have Configure iDRAC permission F NOTE This option is applicable only to iDRACE Subcommand Description usercertupload Uploads a user certificate or a user CA certificate from the client to iDRAC6 Synopsis racadm usercertupload t lt type gt f lt filename gt i lt index gt Table 2 49 describes the usercertupload subcommand options 142 RACADM Subcommand Details Table 2 49 usercertupload Subcommand Options Option Description t Specifies the type of certificate to upload either the CA certificate or server certificate l user certificate 2 user CA certificate f Specifies the file name of the certificate to be uploaded If the file is not specified the sslcert file in the current directory is selected i Index number of the user Valid values 1 16 The usercertupload command returns 0 when successful and returns a nonzero number when unsuccessful Example racadm usercertupload t 1 f c cert cert txt i 6 RACADM Subcommand Details 143 usercertview F NOTE To use this subcommand you must have Configure iDRAC permission F NOTE
120. e iDRAC6 IPv6 sixth address Legal Values String representing a valid IPv6 entry Default iDRAC6 and CMC Property Database Group and Object Descriptions 259 cfglPv6Address7 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 seventh address Legal Values String representing a valid IPv6 entry Default cfglPv6Address Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 eighth address Legal Values String representing a valid IPv6 entry Default cfglPv6Address9 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 ninth address Legal Values String representing a valid IPv6 entry Default cfglPv6Address10 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 tenth address Legal Values String representing a valid IPv6 entry Default 260 iDRAC6 and CMC Property Database Group and Object Descriptions cfglPv6Address11 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 eleventh address Legal Values String representing a valid IPv6 entry Default cfgIPv6Address12 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 twelfth address Legal Values String representing a valid IPv6 entry Default cfgIPv6Address13 Read Only F NOTE This object is applicable only
121. e in the format DD MM Date YYYY HH MM SS where e DD Day of the week e MM Month Date Date YYYY Year HH hour e MM Minutes e SS Seconds Timestamp of the cumulative power consumption cfgServerCumulativePowerClear Write Only F NOTE This object is applicable only for iDRAC6 Description Legal Values Default Clears the cfgServerCumulativePowerConsumption and cfgServerCumulativePowerConsumptionTimeStamp values A string of up to 32 characters None cfgServerPeakPowerClear Write Only K NOTE This object is applicable only for iDRAC6 Description Legal Values Default Clears the cfgServerPeakPowerConsumption and cfgServerPeakPowerConsumptionTimestamp values A string of up to 32 characters None iDRAC6 and CMC Property Database Group and Object Descriptions 251 cfgServerPowerPCleAllocation Read Write F NOTE This object is applicable only for iDRAC6 F NOTE This object is applicable for iDRAC6 Enterprise only for specific Blade Servers and not for IDRAC6 on Rack and Tower Servers or CMC F NOTE You must have Administrator privileges to modify the value for this object Description Amount of power allocated to the PCIe cards Legal Values OW For platforms that do not support PCIe cards 100W 500W For platforms that support PCIe cards Default 0 For platforms that do not support PCIe cards 500W For platforms that support PCIe cards cfgKVMIInfo F
122. e this object with the config or getconfig subcommands You must supply an index group number to use these commands as follows i lt index group gt NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option The following sections provide information about the objects in the cfgUserAdmin group cfgUserAdminIndex Read Only Description The unique index of a user For CMC the index number is used to specify a unique group name Only valid for indexed groups Legal Values For iDRAC6 This parameter is populated based on the existing instances For CMC The parameter is specified by a decimal integer from 1 16 Default lt index of the instance gt iDRAC6 and CMC Property Database Group and Object Descriptions 171 cfgUserAdmin pmiLanPrivilege Read Write F NOTE This object property is specific to iDRAC6 Description The maximum privilege on the IPMI LAN channel Legal Values 2 User 3 Operator 4 Administrator 15 No access Default 4 User 2 15 All others cfgUserAdminPrivilege Read Write Description This property specifies the role based authority privileges allowed for the user The value is represented as a bit mask that allows for any combination of privilege values Table 3 3 describes the user pr
123. e used lt IPy4Address gt lt netmask gt and lt gateway gt must be typed as dot separated strings racadm setniccfg s 192 168 0 120 255 255 255 0 19216801 s6 Enables static Pv6 settings The IPv6 address Prefix Length and the IPv6 Gateway can be specified RACADM Subcommand Details 121 setractime F NOTE To use this subcommand you must have Administrator privilege Subcommand Description setractime Sets the date and time on the CMC Synopsis racadm setractime d lt yyyymmddhhmmss mmmmmmsoff gt racadm setractime l YYYYMMDDhhmmss Z timezone timezone prefix Table 2 35 describes the setractime subcommand options Table 2 35 setractime Subcommand Options Option Description d Sets the time in the string yyyymmddhhmmss mmmmmmsoff where e yyyy isa the year mmis the month ddis the day hh is the hour mmis the minutes e ss is the seconds mmmmmm is the number of microseconds e sisa plus sign or a minus sign which indicates the sign of the offset offis the offset in minutes NOTE The off is the offset in minutes from GMT and must be in 15 minute increments The timezone is represented as an offset from GMT and the clock does not automatically adjust for daylight savings time for d option 122 RACADM Subcommand Details Table 2 35 setractime Subcommand Options continued Option Description z lt zone gt Sets
124. eNiclPv4Enable cfeNicUseDhcp iDRAC6 and CMC Property Database Group and Object Descriptions 159 cfgIPv6Enable cfglPvOAutoContig cfgDNSDomainNamelromDHCP cfgDNSDomainName Read Write The network administrator must ensure that these DHCP servers are configured to provide the same DNS domain name to the CMC otherwise the domain name becomes unpredictable cfgDNSDomainName Read Write Description This is the DNS domain name This parameter is only valid if cfg DNSDomainNameFromDHCP is set to 0 FALSE Legal Values A string of up to 254 ASCII characters At least one of the characters must be alphabetic Characters are restricted to alphanumeric and NOTE Microsoft Active Directory only supports Fully Qualified Domain Names FODN of 64 bytes or fewer Default lt blank gt cfgDNSRacName Read Write Description Displays the iDRAC6 or CMC name which is rac service tag by default This parameter is only valid if cfgDNSRegisterRac is set to 1 TRUE Legal Values A string of up to 63 ASCII characters At least one character must be alphabetic NOTE Some DNS servers only register names of 31 characters or fewer Default For iDRAC idrac lt service tag gt For CMC cmc lt service tag gt 160 iDRAC6 and CMC Property Database Group and Object Descriptions cfgDNSRegisterRac Read Write Description Registers the iDRAC6 or CMC name on the DNS server When you set this parameter th
125. ead Write Description Active Directory Domain in which iDRAC6 or CMC resides Legal Values Any printable text string of up to 254 characters with no white space Default lt blank gt cfgADRacName Read Write Description Name of iDRAC6 or CMC as recorded in the Active Directory forest Legal Values Any printable text string of up to 254 characters with no white space Default lt blank gt cfgADRootDomain F NOTE This object is applicable only to CMC Description Specifies the root domain of the domain forest Legal Values Any printable text string of up to 254 characters with no white space Default lt blank gt cfgADEnable Read Write Description Enables or disables Active Directory user authentication on iDRAC6 or CMC If this property is disabled only local iDRAC6 or CMC authentication is used for user logins Legal Values 1 TRUE 0 FALSE Default 0 210 iDRAC6 and CMC Property Database Group and Object Descriptions cfgADSCLEnable F NOTE This object is applicable only to CMC Description Enables you to log on to the CMC without enabling the Smart Card login Legal Values Enable 0 Disable Default 0 cfgADSS0Enable Read Write Description Enables or disables Active Directory single sign on authentication on iDRAC6 Legal Values 1 TRUE 0 FALSE Default 0 cfgADDomainController F NOTE This object is applicable only to CMC Description Specifies the LDAP server from whic
126. eboot Option sections in the iDRAC6 Enterprise for Blade Servers User Guide Synopsis racadm clearasrscreen closessn F NOTE To use this subcommand you must have Administrator permission Subcommand Description closessn Closes a communication session on the device Use getssninfo to view a list of sessions that can be closed using this command Synopsis racadm closessn i lt session id gt racadm closessn a racadm closessn u lt username gt RACADM Subcommand Details 39 Table 2 2 describes the closessn subcommand options Table 2 2 closessn Subcommand Options and Descriptions Option Description i lt sessionid gt The session ID of the session to close which can be retrieved using racadm getssninfo subcommand NOTE Session executing this command cannot be closed a Closes all sessions u lt user name gt Close all sessions for a particular user name NOTE u option can be used in local RACADM only if the username contains upto 16 characters If the user name contains more than 16 characters use one of the following options to close a session Local RACADM i option Remote RACADM u option or i option Examples racadm closessn i 1234 Closes the session 1234 racadm closessn u root Closes all the sessions for root user racadm closessn a Closes all the sessions 40 RACADM Subcommand Details clrraclog F NOTE T
127. ee the coredump subcommand for more information on viewing a coredump Synopsis racadm coredumpdelete deploy F NOTE To use this subcommand you must have Server Administrator privilege Subcommand Description deploy Contigures the static IP address subnet mask gateway and password for the root user on iDRAC for the specified Server F NOTE You can also use setniccfg to configure static IP address subnet mask and gateway as well as DHCP speed and duplex properties RACADM Subcommand Details 47 Synopsis racadm dep loy m lt module gt u root p password s lt ipaddress gt lt subnet gt lt gateway gt b lt device gt o lt no yes gt e racadm deploy m lt module gt u root p lt password gt s 6 lt ipv6Address gt lt prefixlen gt lt gateway gt b lt device gt o lt nolyes gt K NOTE lt prefixlen gt must be a number between 0 and 128 racadm depl 6 racadm depl Loy m lt module gt u root p lt password gt d Loy a u root p lt password gt Table 2 5 describes the deploy subcommand options Table 2 5 deploy Subcommand Options Option Description b lt device gt Specifies the first boot device must be used with 0 Use with m lt module gt to specify for a individual server or with a for all servers Legal values device None PXE HDD CD DVD vFDD vCD DVD iSCSI SD FDD o lt no yes gt Ind
128. efault 0000000000000000000000000000000000000000 cfglpmiPetCommunityName Read Write Description The SNMP community name for traps Legal Values A string of up to 18 characters Default public 234 iDRAC6 and CMC Property Database Group and Object Descriptions cfglpmiPetlpv6 This group is applicable only for iDRAC6 and is used to configure IPv6 platform event traps on the managed server The following sections provides information about the objects in the cfgIpmiPetIpv6 group cfglpmiPetlPv6lndex Read Only Description Unique identifier for the index corresponding to the trap Legal Values 1 4 Default lt index value gt cfglpmiPetIPv6AlertDestlpAddr Description Configures the IPv6 alert destination IP address for the trap Legal Values IPv6 address Default lt blank gt cfglpmiPetIPv6AlertEnable Read Write Description Enables or disables the IPv6 alert destination for the trap Legal Values 1 TRUE 0 FALSE Default 0 cfglpmiPef This group is applicable only for iDRAC6 and is used to configure the platform event filters available on the managed server The event filters can be used to control policy related to actions that are triggered when critical events occur on the managed server The following sections provides information about the objects in the cfgIpmiPef group iDRAC6 and CMC Property Database Group and Object Descriptions 235 cfglpmiPefName Read Only Description Specifies the name of the
129. ent of an error the command displays the test that failed and all the the tests performed earlier to the test that failed including all the error messages Examples testfeatur f ad u user domain p secret SUCCESSFUL User permissions are xxxxxppp F NOTE The last three digits are the user s permissions 138 RACADM Subcommand Details testfeature f adkrb u user name domain name SUCCESSFUL User permissions are 80000fff testfeature f ldap u harold p barrel SUCCESSFUL User permissions are O0x00000fff testfeature f adkrb Synopsis testfeature f adkrb u lt username gt d diagnostic message level gt This subcommand tests the Active Directory configuration using Kerberos authentication single sign on or Smart Card login Use the optional d switch to obtain additional diagnostic information as needed This subcommand when executed performs the following Checks command syntax Verifies if the required system resources are available Validates Active Directory configuration Verifies if the SSL certificate and certificate signing request key exists Acquires LDAP and Global Catalog Service records from DNS Verifies if the CMC can acquire CMC LDAP and Global Catalog servers FQDN through reverse IP lookups Verifies that the CMC principal name matches the principal name in the uploaded Keytab file Verifies that the CMC acquires a Kerberos TGT Acquires user privileges
130. er when unsuccessful Example racadm sslkeyupload t 1 f c sslkey txt sslresetcfg F NOTE To use this subcommand you must have Chassis Configuration Administrator privilege for CMC and Configure iDRAC permission for iDRAC Subcommand Description sslresetcfg Restores the web server certificate to factory default and restarts web server The certificate takes effect 30 seconds after the command is entered Synopsis racadm sslresetcfg Example racadm sslresetcfg Certificate generated successfully and webserver restarted F NOTE For more information on managing SSL certificates see the Securing CMC Communications Using SSL and Digital Certificates section in the Dell Chassis Management Controller User Guide RACADM Subcommand Details 135 testemail Subcommand Description testemail Sends a test e mail from iDRAC6 to a specified destination Prior to executing the test e mail command ensure that the SMTP server is configured and the specified index in the RACADM cfgEmailAlert group is enabled and configured properly See cfgEmailAlert on page 176 for more information Synopsis racadm testemail i lt index gt Table 2 44 provides a list and associated commands for the cfgEmailAlert group Table 2 44 testemail Configuration Action Command Enable the alert racadm config g cfgEmailAlert o cfgEmailAlertEnable i 11 Set the destination e mail racadm
131. erface The Chassis Management Controller CMC Secure Digital SD Card Technical Specification provides minimum BIOS and firmware version installation and usage information Click Enterprise System Management to view documents for OpenManage Server Administrator and Dell Update Package The Dell OpenManage IT Assistant User s Guide provides information about IT Assistant The Dell OpenManage Server Administrator s User s Guide provides information about installing and using Dell OpenManage Server Administrator The Dell Update Packages User s Guide provides information about obtaining and using Dell Update Packages as part of your system update strategy The Glossary provides information about the terms used in this document The following system documents are also available to provide more information about the system in which CMC is installed The Rack Installation Guide and Rack Installation Instructions included with your rack solution describe how to install your system into a rack The Hardware Owner s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components Documentation specific to your third party management console application Introduction 31 Documentation for any components you purchased separately provides information to configure and install these options Release notes or readme files may be included to provi
132. escription Displays the MAC address of the server NIC 1 Legal Values None Default None cfgServerNic2MacAddress Read only F NOTE This object is applicable only to CMC Description Displays the MAC address of the server NIC 2 Legal Values None Default None cfgServerNic3MacAddress Read only F NOTE This object is applicable only to CMC Description Displays the MAC address of the server NIC 3 Legal Values None Default None 204 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerNic4MacAddress Read only F NOTE This object is applicable only to CMC Description Displays the MAC address of the server NIC 4 Legal Values None Default None cfgServerPriority Read Write K NOTE This object is applicable only to CMC Description Sets the priority level allotted to the server in the chassis for power budgeting purposes Legal Values 1 9 in descending priority where 1 holds the highest priority Default l cfgServerNicEnable Read Write F NOTE This object is applicable only to CMC Description Enables or disables LAN channel Legal Values 1 enable 0 disable Default None cfgServerIPMlOverLanEnable Read Write F NOTE This object is applicable only to CMC Description Enables or disables IPMI LAN channel Legal Values enable 0 disable Default None iDRAC6 and CMC Property Database Group and Object Descriptions 205 cfgServerPowerBudgetAllocation
133. ession has not responded for session sharing request by subsequent user the next session user gets an access denied error after the default timeout value of 30 seconds 1 If the user of the first session has not responded for session sharing request by subsequent user the next session user gets a read only access after the default timeout value of 30 seconds 2 If the user of the first session has not responded for session sharing request by subsequent user the next session user gets administrator access after default timeout value of 30 seconds Default 0 cfgRacTunePluginType Read Write F NOTE This object property is applicable only to iDRAC6 Description Specifies the plug in type to use when running virtual console from browser Legal Values 0 Use Active X Native Plugin 1 Use Java Plugin Default 0 Active X Native Plugin iDRAC6 and CMC Property Database Group and Object Descriptions 197 198 ifcRacManagedNodeOs F NOTE This object is applicable only to iDRAC6 This group contains properties that describe the managed server operating system One instance of the group is allowed The following sections provides information about the objects in the ifcRacManagedNodeOs group ifcRacMnOsHostname Read Only Description The host name of the managed server Legal Values A string of up to 255 characters Default lt blank gt ifcRacMnOsOsName Read Only Description The operating system name of the
134. etails 51 featurecard F NOTE To use this subcommand you must have Chassis Configuration Administrator privilege Subcommand Description featurecard Verifies proper SD card installation and displays the SD card status Table 2 7 lists the status messages returned by the command Table 2 7 Status Messages Returned by featurecard s Command Status Message Actions No feature card inserted Check the CMC to verify that the SD card was properly inserted In a redundant CMC configuration make sure the CMC with the SD feature card installed is the active CMC and not the standby CMC The feature card inserted is valid and No action required contains the following feature s FlexAddress The feature card is bound to this chassis No features active on the chassis Install the SD card into the CMC The feature card inserted is valid and Remove the SD card locate and install the SD contains the following feature s card for the current chassis FlexAddress The feature card is bound to another chassis svctag ABC1234 SD card SN 01122334455 The feature card inserted is valid and The feature card can be moved to another contains the following feature s chassis or can be reactivated on the current FlexAddress The feature card is not chassis To reactivate on the current chassis bound to any chassis enter racadm racreset until the CMC module with the feature card installed becomes acti
135. etraclog ed AE 2 86 getiactime is 00 EER RM ERROR EE 87 getredundancymode 88 getsels EE a OER ee a ee Ie ee 89 getsensorinfo 90 getslotname ES Se 91 getssninfo ss e eee nran eee Se 93 getsvctag L pu ee h S ee a 94 getsysinlo ss Sa EA fy a lw y Das EIE 2 Q AA 95 gettracelog ee 99 getuscversion X 100 getversion SS ee es 101 ifconfig 602 25 aoa 8 4 ER K S Ay ENE hua t aN Ba 104 krbkeytabupload 105 kmcSelfSignedCertGen 106 localConRedirDisable 106 Netstat sk ee a A itis apa oy 107 PING uya u hat ER RE Q t uyay EE a 107 Contents Contents racdump EE EE Ee ee 109 racresel 225 444 SEE Re WER SR Q P he 112 racresetcfg Re 113 remoteimage _ 114 serveraction ES se 114 setassettag SS Se 115 setchassisname 116 setflexadd r ___ 117 setledin 2 eS 2 6 EA ER ash U RR ek 118 SeU ICC g y p EER ee OE ES 120 setractime 121 setslotname Ee 123 setsysinff0 0 ee 124 sshpkauth X EE ee 125 sslcertdownload 127 sslcertupload 128 sslceriview 130 sslesrden atari WREED SS RU DADE Rg
136. etuscversion RR R yy GY RR AAS ee ifconfig IR lt IRI VY krbkeytabupload VY lt VY PP PL kmcSelfSignedCertGen Y A SGP vy GF RR localConRediDisable lt vy vv RR netstat vR lt IR Q VY ping IR lt IR Q lt ping6 IR y IR y SH 28 Introduction Table 1 3 RACADM Subcommands continued Subcommand iDRACE6 on Blade Servers iDRAC6 on Rack and Tower Servers CMC Telnet Local SSH Serial Remote RACADM RACADM Telnet Local Remote Telnet Remote SSH S RACADM RACADM SSH RACADM Serial racdump x racreset racresetcfg remoteimage serveraction setassettag setchassisname setflexaddr setled setnicctg setractime setslotname setsysinfo sshpkauth sslcertdownload sslcertupload sslcertview sslkeyupload sslkeyupload BS SMS WS RW BW AAS SS lt lt S lt S S SS MM MS BW BW SS lt lt S S S SS SS MS BW BW MAS lt lt lt lt BS SMS MAAS lt MASS lt lt lt S S S S SS BW BW WW SIM MASS lt lt S lt S S SS BB SS BW BW lt amp SS lt R LILIR RL lt q SS SS SS lt lt lt lt BS 4 S S S S S 6 6 6 6 lt lt lt lt lt lt lt Introduction 29 Table 1 3 RACADM Subcommands continued Subcommand iDRAC6 on Blade iDRAC6 onRack and CMC Servers Tower Servers Re RACADM RAC
137. from the Active Directory server Checks the time to acquire user privileges with the allotted time to login NOTE In the event of an error the command outputs all tests performed up to and including the test that failed as well as all error messages RACADM Subcommand Details 139 testfeature f ldap Synopsis testfeature f ldap u lt username gt p lt password gt d lt diagnostic message level gt This subcommand tests LDAP configuration and operation and reports success as each stage of the authentication process proceeds On successful completion this command prints the CMC privileges assumed by the specified lt username gt If a failure occurs the command terminates with an error message that displays the required corrective action Use the optional d switch to obtain additional diagnostic information as needed testtrap F NOTE To use this subcommand you must have Test Alerts permission Subcommand Description testtrap Tests the RAC s SNMP trap alerting feature by sending a test trap from iDRAC6 to a specified destination trap listener on the network For iDRAC6 only before you execute the testtrap subcommand ensure that the specified index in the RACADM cfgIpmiPet group is configured properly For more information see cfglpmiPet on page 237 Table 2 47 provides a list and associated commands for the cfglpmiPet group F NOTE The cfglpmiPet group is applicable only for iDRAC6
138. gDNSServerl Read Write cfgDNSServer2 Read Write cfgNicEnable Read Write cfgNiclpAddress Read Write cfgNicNetmask Read Write cfgNicGateway Read Write cfgNicUseDhcp Read Write cfgNicMacAddress Read Only cfgRemoteHosts cfgRhostsFwUpdateTftpEnable Read Write cfgRhostsFwUpdatelpAddr Read Write cfgRhostsFwUpdatePath Read Write cfgRhostsSmtpServerlpAddr Read Write cfgRhostsNtpEnable cfgRhostsNtpServerl cfgRhostsNtpServer2 cfgRhostsNtpServer3 cfgRhostsNtpMaxDist cfgRhostsSyslogEnable Read Write cfgRhostsSyslogPort Read Write cfgRhostsSyslogServer1 Read Write cfgRhostsSyslogServer2 Read Write cfgRhostsSyslogServer3 Read Write cfgRhostsSyslogPowerLoggingEnabled 170 cfgRhostsSyslogPowerLoggingInterval 170 cfgUserAdmin 171 cfgUserAdminIndex Read Only 171 cfgUserAdminIpmiLanPrivilege Read Write 172 cfgUserAdminPrivilege Read Write 172 cfgUserAdminUserName Read Write 174 cfgUserAdminPassword Write Only 175 cfgUserAdminEnable Read Write 175 cfgUserAdminSolEnable Read Write 175 cfgUserAdminIpmiSerialPrivilege Read Write 176 cfgEmailAlertt 176 cfgEma
139. h you want the CMC to obtain user names Must be used with cfsADSpecifyServerEnable Legal Values Valid IP address or fully qualified domain name FODN Default None cfgADDomainController1 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the LDAP server for user names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None iDRAC6 and CMC Property Database Group and Object Descriptions 211 cfgADDomainController2 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the LDAP server for user names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None cfgADDomainController3 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the LDAP server for user names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None cfgADAuthTimeout Read Write F NOTE To modify this property you must have Configure iDRAC permission Description Specifies the number of seconds to wait for Active Directory authentication requests to complete before timing out Legal Values 15 300 secon
140. iDRAC6 on Rack CMC Servers and Tower Servers idRacInfo s s cfgLanNetworking s s s cfgRemoteHosts s s s cfgUserAdmin ef s s cfgEmailAlert s s s cfgSessionManagement s s s cfgSerial s s cfgOobSnmp s s s cfgTraps s cfgRacTuning s s s ifcRacManagedNodeOs s s cfgRacSecurity s cfgRacSecurityData q s s cfgRacVirtual ef Sf cfgServerInfo s s 152 iDRAC6 and CMC Property Database Group and Object Descriptions Table 3 1 Supported Object Groups continued Subcommand iDRAC6 on Blade iDRAC6 on Rack CMC Servers and Tower Servers cfgActiveDirectory cfgLDAP cfgLdapRoleGroup cfgStandardSchema cfgChassisPower cfgIpmiSol cfgIpmiLan cfgIpmiPetIpv6 cfglpmiPef cfglpmiPet cfgUserDomain cfgServerPower cfgKVMInfo cfgAlerting cfgServerPowerSupply cfg Pv6LanNetworking cfgCurrentLanNetworking Read only cfgCurrentIPv6LanNetworking Read only cfgIPV6URL BS BR RBS BR RBS 6 66 4 SS lt lt lt BR S GG BSS MA BW RB BW RB RWS lt lt lt lt SS Me BSS MASS SS SI SS MS lt lt lt cfslpmiSerial iDRAC6 and CMC Property Database Group and Object Descriptions 153 Table 3 1 Supported Object Groups continued Subcommand iDRAC6 on Blade iDRAC6 on Rack CMC Servers and Tower Servers cfgSmartCard s s cfgNetTuning s s cfgSensorRedundan
141. icable only to CMC Description Specifies the location of the specified server 1 16 in the chassis Legal Values None Default None 202 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerServiceTag Read only F NOTE This object is applicable only to CMC Description Displays the service tag of the specified server Legal Values None Default None cfgServerName Read Write K NOTE This object is applicable only to CMC Description Displays the name of the specified server Legal Values Maximum of 15 non extended ASCII characters ASCII codes 32 through 126 For more information see Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands on page 33 Default SLOT lt slot number gt cfgServerFW Read only F NOTE This object is applicable only to CMC Description Displays the server s IDRAC management firmware revision Legal Values None Default None cfgServerBI0S Read only F NOTE This object is applicable only to CMC Description Displays the server s BIOS revision Legal Values None Default None iDRAC6 and CMC Property Database Group and Object Descriptions 203 cfgServerBmcMacAddress Read only F NOTE This object is applicable only to CMC Description Displays the BMC MAC address of the specified server Legal Values None Default None cfgServerNic1MacAddress Read only F NOTE This object is applicable only to CMC D
142. ically assigns IPv6 addresses If this value is set to 1 the CMC obtains address and route information using stateless auto configuration and DHCPv6 Legal Values 1 TRUE 0 FALSE Default For iDRACE 0 For CMC 1 F NOTE The CMC uses its MAC address for its DUID DUID LL when communicating with a DHCPv6 server cfglPv6LinkLocalAddress Read 0nly F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 link local address Legal Values A string representing a valid Pv6 entry Default cfglPv6Address2 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 second address Legal Values A string representing a valid Pv6 entry Default 258 iDRAC6 and CMC Property Database Group and Object Descriptions cfglPv6Address3 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 third address Legal Values String representing a valid IPv6 entry Default cfgIPv6Address4 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 fourth address Legal Values String representing a valid IPv6 entry Default cfglPv6Address5 Read Only F NOTE This object is applicable only for iDRAC6 Description The iDRAC6 IPv6 fifth address Legal Values String representing a valid IPv6 entry Default cfglPv6Address6 Read Only F NOTE This object is applicable only for iDRAC6 Description Th
143. icates if the server should boot from the device once must be used with o Use with m lt module gt to specify for a individual server or with a for all servers a Creates and enables an iDRAC root user if it does not already exist and is executed on all the existing servers in the chassis u root Indicates that the lt password gt is supplied for the root user on the server root is a constant parameter the only value that is valid with the u option m lt module gt Specifies the server you want to configure Legal values server n where n 1 16 p spassword Specifies the password for the root user on the server 48 RACADM Subcommand Details Table 2 5 deploy Subcommand Options continued Option Description s lt ipaddress subnet gateway gt Sets the IP address subnet mask and gateway for the specified server separated by single spaces ipaddress A string representing a valid IP address For example 192 168 0 20 subnet A string representing a valid subnet mask For example 255 255 255 0 gateway A string representing a valid gateway address For example 192 168 0 1 d Enables DHOP for the specified server NOTE The s and d options cannot be used together in the same command 6 Enables IPv6 auto configuration when used with d Sets static IPv6 addresses when used with s Example EZ racadm deploy m server 8
144. ilAlertIndex Read Only 176 cfgEmailAlertEnable Read Write 177 cfgEmailAlertAddress Read Write 177 cfgEmailAlertCustomMsg Read Write 177 cfgEmailAlertEmailIName 177 cfgSessionManagement 178 cfgSsnMgtRacadmTimeout Read Write 178 cfgSsnMgtConsRedirMaxSessions Read Write 179 cfgSsnMgtWebserverTimeout Read Write 179 cfgSsnMgtSshldleTimeout Read Write 180 cfgSsnMgtTelnetidleTimeout Read Write 181 cigSerial ss ss MEE s BOE EE N ROES RR a 181 cfgSerialBaudRate Read Write 182 cfgSerialConsoleEnable Read Write 182 cfgSerialConsoleQuitKey Read Write 183 cfgSerialConsoleldleTimeout Read Write 184 cfgSerialConsoleNoAuth Read Write 184 cfgSerialConsoleCommand Read Write 184 cfgSerialConsoleColumns 184 Contents 10 Contents cfgSerialHistorySize Read Write 185 cfgSerialCom2RedirEnable Read Write 185 cfgSerialSshEnable Read Write 185 cfgSerialTelnetEnable Read Write 186 cfgOobSnmp 186 cfgOobSnmpAgentCommunity Read Write 187 cfgOobSnmpAgentEnable Read Write 187 Ciglraps si ss EE ae RR SR RE Pe OM 187 cfgTrapslndex Read Only 188 cfgtrapsEnable 188 cfgTrapsAlertDestIpAddr 188 cfgIrapsCommunityName 188 cfgRacTuning
145. ils getassettag F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getassettag Displays the asset tag for the chassis Synopsis racadm getassettag m lt module gt Table 2 12 describes the getassettag subcommand options Table 2 12 getassettag Subcommand Options Option Description m lt module gt Specifies the module whose asset tag you want to view Legal value chassis Example racadm getassettag m chassis or racadm getassettag chassis 78373839 33 getchassisname F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getchassisname Displays the name of the chassis Synopsis racadm getchassisname RACADM Subcommand Details 61 Example racadm getchassisname PowerEdge 2955 getconfig Subcommand Description getconfig Retrieves iDRAC6 configuration parameters individually or all iDRAC6 configuration groups may be retrieved and saved to a file Synopsis racadm getconfig f lt filename gt racadm getconfig g lt groupName gt i lt index gt racadm getconfig u lt username gt racadm getconfig h racadm getconfig g lt groupName gt o lt objectName gt i index Input Table 2 13 describes the getconfig subcommand options Table 2 13 getconfig Subcommand Options Option Description f The f lt filename gt option
146. in watts over the time since the value was last cleared cfgChassisMinPowerTimestamp Read Only The timestamp recorded when the minimum system power occurred cfgChassisPowerStatus Read Only Description Indicates the power status of the chassis Legal Values 1 other 2 unknown 3 OK 4 non critical 5 critical 6 non recoverable Default None cfgChassisRedundantState Read Only Description Enables or disables power redundancy for the chassis Legal Values 0 none 1 full Default None cfgChassisPowerCap Read Write Description Indicates the maximum power consumption limit in watts for the entire chassis The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting Legal Values 2715 16685 watts Default 16685 watts 226 iDRAC6 and CMC Property Database Group and Object Descriptions cfgChassisPowerCapF Read Write Description Legal Values Default Indicates the maximum power consumption limit in watts for the entire chassis Use cfgChassisPowerCapF when power consumption is to be changed regardless of whether server throttling is required This command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration 2715 16685 watts 16685 watts cfgChassisPowerCapBTU Read Write Description Legal Values Default Indicates the maximum power consumption limit
147. ing sections provides information about the objects in the cfgIPv6LanNetworking group cfgIPv6Enable Read Write Description Enables or disables iDRAC6 or CMC IPv6 stack Legal Values 1 TRUE 0 FALSE Default 0 cfgIPv6Address F NOTE This object is applicable only for CMC Description Assigns a static IPv6 address to the CMC This property is used only if cfg Pv6AutoConfig is set to 0 false Legal Values A string representing a valid IPv6 address For example 2001 DB8 1234 5678 9ABC DE 1 C00C BEEF Default 256 iDRAC6 and CMC Property Database Group and Object Descriptions cfglPv6Address1 Read Write Description iDRAC6 or CMC IPv6 address Legal Values String representing a valid IPv6 entry Default cfgIPv6Gateway Read Write Description iDRAC6 or CMC gateway IPv6 address NOTE For CMC this property is used only if cfglPv6AutoConfig is set to 0 false Legal Values String representing a valid IPv6 entry Default cfgIPv6PrefixLength Read Write Description The prefix length for iDRAC6 or CMC IPv6 address1 NOTE For CMC this property is used only if cfglPv6AutoConfig is set to 0 false Legal Values For iDRAGG 1 128 For CMC 0 128 Default 64 iDRAC6 and CMC Property Database Group and Object Descriptions 257 cfglPv6AutoConfig Read Write Description Enables or disables the IPv6 Auto Configuration option NOTE If this value is set to 0 the CMC disables auto configuration and stat
148. inutes Default 5 Example racadm getconfig g cfgRemoteHosts m server lt n gt cfgRhostsFwUpdateTftpEnable 1 cfgRhostsFwUpdatelIpAddr 0 0 0 0 cfgRhostsFwUpdatePath cfgRhostsSmtpServerIpAddr localhost localdomain cfgRhostsNtpEnable 0 cfgRhostsNtpServerl cfgRhostsNtpServer2 cfgRhostsNtpServer3 cfgRhostsNtpMaxDist 16 cfgRhostsSyslogEnable 0 cfgRhostsSyslogPort 514 cfgRhostsSyslogServerl cfgRhostsSyslogServer2 cfgRhostsSyslogServer3 cfgRhostsSyslogPowerLoggingEnabled 1 cfgRhostsSyslogPowerLoggingInterval 5 170 iDRAC6 and CMC Property Database Group and Object Descriptions cfigUserAdmin This group provides configuration information about the users who are allowed to access iDRAC6 or CMC through the available remote interfaces Up to 16 instances of the user group are allowed Each instance represents the configuration for an individual user F NOTE In the current CMC firmware version the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated changing the value of one property causes the value of the other property to change For example if a user does not have login privilege the user is disabled by default When you enable the user by changing the value of UserAdminEnable to 1 the right most digit of the UserAdminPrivilege also becomes 1 On the other hand if you change the right most digit of the UserAdminPrivilege to 0 the value of UserAdminEnable becomes 0 NOTE Us
149. iple servers by separating each server with a comma For example example com sub1 example com cfgLdapPort Read Write Description Port of LDAP over SSL Non SSL port is not supported Legal Values 1 65535 Default 636 iDRAC6 and CMC Property Database Group and Object Descriptions 217 cfgLdapBasedn Read Write Description The Domain Name of the branch of the directory where all searches should start from Legal Values String Maximum length 254 Default Null cfgLdapUserAttribute Read Write Description Specifies the user attribute to search for If not configured the default used is uid It is recommended to be unique within the chosen baseDN otherwise a search filter must be configured to ensure the uniqueness of the login user If the user DN cannot be uniquely identified login fails with error Legal Values String Maximum length 254 Default Null uid if not configured cfgLdapGroupAttribute Read Write Description Specify which LDAP attribute is used to check for group membership This should be an attribute of the group class If not specified then iDRAC6 or CMC uses the member and unique member attributes Legal Values String Maximum length 254 Default Null 218 iDRAC6 and CMC Property Database Group and Object Descriptions cfgLdapGroupAttributelsDN Read Write Description Legal Values Default When it is set to 1 iDRAC6 compares the userDN retrieved from the directory to compare to
150. iptions Table 3 5 Bit Masks for Role Group Privileges continued Role Group Privilege Bit Mask Configure Users 0x00000004 Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 cfgChassisPower This group is applicable only to CMC and contains parameters to display or configure power for the chassis F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property you must have Chassis Configuration Administrator privilege F NOTE You can configure any setting thatis not preceded by the hash sign in the output To modify a configurable object use the o option The following sections provides information about the objects in the cfgChassisPower group cfgChassisInPower Read Only Indicates the cumulative input power consumption data in watts and BTU hr captured from all healthy and functional PSUs in the chassis cfgChassisPeakPower Read Only The maximum system input power consumption in watts since the value was last cleared by a user cfgChassisPeakPowerTimestamp Read Only The timestamp recorded when the peak input power consumption value occurred iDRAC6 and CMC Property Database Group and Object Descriptions 225 cfgChassisMinPower Read Only The minimum system input power consumption value
151. iptions in your racadm session racadm help list racadm subcommand description help lt subcommand gt display usage summary for a subcommand list racadm subcommand description lt subcommand gt subcommand arp chassisaction gt display usage summary for a display the networking arp table execute chassis or switch power up down cycle or KVM powercycle clrraclog clear the CMC log clrsel cmcchangeover CMC from active to clear the System Event Log SEL Changes the redundant state of the standby and vice versa config modify CMC configuration properties setniccfg gt properties modify network configuration set the time on the CMC setractime setslotnam chassis setsysinfo location sslcertview the CMC testemail sets the name of the slot in the set the chassis name and chassis display a CA server certificate in test CMC e mail notifications testfeatur testtrap test CMC feature x test CMC SNMP trap notifications traceroute determine the route of a packet traceroute6 determine the route of a packet Example for racadm lt subcommand gt racadm getsysinfo RACADM Subcommand Details 35 getsysinfo display general CMC and system information Usage racadm getsysinfo d c A 4 6 Valid Options q show CMC information c show chassis infor
152. is an indexed group which currently only supports two indices F NOTE This second index is not supported for this release For more information on generating certificate signing requests see the subcommand sslkeyupload on page 133 The following sections provides information about the objects in the cfgRacSecurityData group cfgRacSecCsrindex Description Specifies the CSR index Legal Values 1 Server certificate 2 KMS certificate Default lt blank gt cfgRacSecCsrKeySize Description Specifies the keysize of the CSR Legal Values 1024 2048 Default 1024 cfgRacSecCsrCommonName Read Write Description Specifies the CSR Common Name CN that must be an IP or iDRAC or CMC name as given in the certificate Legal Values A string of up to 254 characters Default lt blank gt 284 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacSecCsrOrganizationName Read Write Description Specifies the CSR Organization Name O Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrOrganizationUnit Read Write Description Specifies the CSR Organization Unit OU Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrLocalityName Read Write Description Specifies the CSR Loyalty L Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrStateName Description Specifies the CSR State Name S Legal Values A string
153. isname chassislocation lt string gt Table 2 37 describes the setsysinfo subcommand options Table 2 37 setsysinfo Subcommand Options Option Description lt string gt Indicates a maximum of 64 non extended ASCII chassis name or location C Sets the chassis name or location Example racadm setsysinfo c chassisname Dell Rack System The chassis name was set successfully RACADM Subcommand Details 125 sshpkauth Subcommand Description sshpkauth Enables you to upload and manage up to 4 different SSH public keys per user You can upload a key file or key text view keys or delete keys This command has three mutually exclusive modes upload view and delete that are determined by the options see Table 2 38 provided for the command Synopsis racadm sshpkauth The upload mode allows you to upload a keyfile or to copy the key text on the command line You cannot upload and copy a key at the same time Local and Remote RACADM racadm sshpkauth i lt 2 to 16 gt k lt 1 to 4 gt f lt filename gt racadm sshpkauth i lt 2 to 16 gt k lt 1 to 4 gt t lt key text gt Telnet ssh serial RACADM racadm sshpkauth i lt 2 to 16 gt k lt 1 to 4 gt t lt key text gt View The view mode allows the user to view a key specified by the user or all keys racadm sshpkauth i lt 2 to 16 gt v k lt 1 to 4 gt racadm sshpkauth i lt 2 to 16 gt v k all 126 RACADM Subcomman
154. isplays the average power value during the last week Legal Values A string of up to 32 characters Default Average power value during the last week 242 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerLastHourMinPower Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the minimum power value during the last hour Legal Values A string of up to 32 characters Default Minimum power value during the last hour cfgServerPowerLastHourMinTime Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the timestamp of minimum power value during the last minute Legal Values A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week e MM Month Date Date e YYYY Year HH hour MM Minutes e SS Seconds Default Minimum power value during the last minute cfgServerPowerLastHourMaxPower Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the maximum power value during the last hour Legal Values A string of up to 32 characters Default Maximum power value during the last hour iDRAC6 and CMC Property Database Group and Object Descriptions 243 cfgServerPowerLastHourMaxTime Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the timestamp of maximum power value during the last hour Legal Values A
155. ity aaa aaa 281 cfgRacSecCsrCommonName Read Write 282 cfgRacSecCsrOrganizationName Read Write 282 cfgRacSecCsrOrganizationUnit Read Write 282 cfgRacSecCsrLocalityName Read Write 282 cfgRacSecCsrStateName Read Write 282 cfgRacSecCsrCountryCode Read Write 283 cfgRacSecCsrEmailAddr Read Write 283 cfgRacSecCsrKeySize Read Write 283 cfgRacSecurityData 284 cfgRacSecCsrindex 284 cfgRacSecCsrKeySize 284 cfgRacSecCsrCommonName Read Write 284 cfgRacSecCsrOrganizationName Read Write 285 cfgRacSecCsrOrganizationUnit Read Write 285 cfgRacSecCsrLocalityName Read Write 285 cfgRacSecCsrStateName 285 cfgRacSecCsrCountryCode 285 cfgRacSecCsrEmailAddr 286 4 Deprecated Commands Groups and Obj OCIS u seats EE GE WE ek 289 Contents 21 Contents Introduction This document provides information about the RACADM subcommands supported RACADM interfaces and property database groups and object definitions for the following iDRAC6 Enterprise on Blade Servers iDRAC6 Enterprise or Express on Rack and Tower Servers Dell Chassis Management Controller CMC Supported RACADM Interfaces The RACADM command line utility provides a scriptable interface that allows you to locally or remotely configure your Remote Access Controller RAC The uti
156. ivilege bit values that can be combined to create bit masks Legal Values For iDRAC6 0x00000000 to 0x000001ff and 0x0 For CMC 0x0000000 0x0000fff and 0x0 Default 0x00000000 Example racadm getconfig g cfgUserAdmin i 1 cfgUserAdminIndex 1 cfgUserAdminEnable 1 cfgUserAdminUserName root cfgUserAdminPassword Write Only cfgUserAdminPrivilege 0x00000fff Table 3 3 lists the bit masks for user priveleges 172 iDRAC6 and CMC Property Database Group and Object Descriptions Table 3 3 Bit Masks for User Privileges iDRAC Specific User Privilege Privilege Bit Mask Login to iDRAC 0x00000001 Configure iDRAC 0x00000002 Configure Users 0x00000004 Clear Logs 0x00000008 Execute Server Control 0x00000010 Commands Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 CMC Specific User Privelege CMC Login User 0x0000001 Chassis Configuration 0x0000002 Administrator User Configuration Administrator 0x0000004 Clear Logs Administrator 0x0000008 Chassis Control Administrator 0x0000010 Super User 0x0000020 Server Administrator 0x0000040 Test Alert User 0x0000080 Debug Command Administrator 0x0000100 Fabric A Administrator 0x0000200 Fabric B Administrator 0x0000400 Fabric C Administrator 0x0000800 iDRAC6 and CMC Property Database Group and Object Descriptions 173 Examples Table 3 4 provides sample privilege
157. k System Power Timestamp 01 08 23 01 27 2009 Minimum System Power 0 W Minimum System Power Timestamp 20 18 30 01 27 2000 Overall Power Health Not OK Redundancy No System Input Power Cap 7928 W Redundancy Policy None Dynamic PSU Engagement Enabled No System Input Max Power Capacity 0 W Input Redundancy Reserve 0 W Input Power Allocated to Servers 0 W RACADM Subcommand Details 83 Input Power Allocated to Chassis Infrastructure 51 watts Total Input Power Available for Allocation 0 W Standby Input Power Capacity 0 W Chassis Power Supply Status Table lt Name gt lt Presence gt lt Power State gt lt Input Current gt lt Input Volts gt lt Output Rating gt PS1 Online On 16 1 A 32 V 2360 W PS2 Not Present Slot Empty A N A N A PS3 Not Present Slot Empty A N A N A PS4 Not Present Slot Empty A N A N A PS5 Not Present Slot Empty A N A N A PS6 Not Present Slot Empty A N A N A Server Module Power Allocation Table lt Slot gt lt Server Name gt lt PowerState gt lt Allocation gt lt Priority gt lt Blade Type gt 1 SLOT 01 N A N A 5 N A 2 SLOT 02 OFF 0 W 5 PowerEdgeM805 3 SLOT 03 ON 164 W 5 N A 4 SLOT 04 ON 155 W 5 5 SLOT 05 ON 180 W 3 6 SLOT 06 ON 80 W 5 PowerEdgeM600 7 SLOT 07 ON 170 W a 8 SLOT 08 N A A 5 N A 9 SLOT 09 N A A 5 N A 10 SLOT 10 Extension 2 N A 5 N A Ki SLOT 11 N A A 5 N A 12 SLOT 12 ON 125 W 5 PowerEdgeM600 13 SLOT 13 N A
158. lays the emulation type for the partition Legal Values String HDD Floppy e CDROM Default None cfgVFlashPartitionOSVolLabel ReadOnly Description Displays the label for the partition that is visible to the operating system Legal Values An alphanumeric string of up to six characters Default None cfgVFlashPartitionFormatType ReadOnly Description Displays the format type of the partition Legal Values String FAT16 e FAT32 EXT2 EXT3 CD RAW Default None iDRAC6 and CMC Property Database Group and Object Descriptions cfgVFlashPartitionAccessType Read Write Description Indicates the partition access permissions It configures the access type to read write Legal Values 0 Read only 1 Read write Default 0 cfgVFlashPartitionAttachState Read Write Description Displays whether the partition is attached or detached Legal Values 1 Attached 0 Detached Default 0 cfgLogging This group is applicable only for iDRAC6 and contains parameters to enable or disable the OEM event log filtering The following section provides information about the objects in the cfgLogging group cfgLoggingSELOEMEventFilterEnable Read Write Description Enables or disables the SEL Log filtering Legal Values 0 SEL Log filtering is Disabled 1 SEL Log filtering is Enabled Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 279 cfgKMSProfile F NOTE This current
159. le object use the o option 186 iDRAC6 and CMC Property Database Group and Object Descriptions The following sections provides information about the objects in the cfgOobSnmp group cfgOobSnmpAgentCommunity Read Write Description Specifies the SNMP Community Name identical to community string used for SNMP traps The community string acts as a password shared between different hosts over the network This community string value must match with that of the other hosts for any kind of communication through SNMP Legal Values A string of up to 31 characters Default public Example racadm getconfig g cfgOobSnmp cfgOobSnmpTrapsEnable 1 cfgOobSnmpAgentCommunity public cfgOobSnmpAgentEnable Read Write Description Enables or disables the SNMP agent in iDRAC6 or CMC Legal Values 1 TRUE 0 FALSE Default 0 cfgTraps This group displays information for and configures delivery of SNMP traps for a specific user F NOTE This object property is applicable only to CMC Use this object with the config or getconfig subcommands F NOTE To use this object property you must have Chassis Configuration Administrator privilege F NOTE You can configure any setting thatis not preceded by the hash sign in the output To modify a configurable object use the o option iDRAC6 and CMC Property Database Group and Object Descriptions 187 cfgTrapslndex Read Only Description Indicates the unigue index of
160. le only for iDRAC6 Description Displays the timestamp of maximum power value during the last day Legal Values A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week MM Month Date Date e YYYY Year HH hour MM Minutes SS Seconds Default Maximum power value during the last day cfgServerPowerLastWeekMinPower Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the minimum power value during the last week Legal Values A string of up to 32 characters Default Minimum power value during the last week 246 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerLastWeekMinPowerTime Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the timestamp of minimum power value during the last week Legal Values A string of up to 32 characters Time in the format DD MM Date YYYY HH MM SS where e DD Day of the week MM Month Date Date e YYYY Year e HH hour MM Minutes SS Seconds Default Minimum power value during the last week cfgServerPowerLastWeekMaxPower Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the maximum power value during the last week Legal Values A string of up to 32 characters Default Maximum power value during the last week iDRAC6 and CMC Property Database
161. list Ifyouruntheracadm help lt deprecated command name gt then the following information is displayed ATTENTION lt command name gt is a deprecated command While execution of this command will still be successful we strongly encourage you to use the new functionality he functionality of this command is now covered by lt list of new functionality gt ype racadm help lt new command name gt to learn more NOTE This information is displayed only for iDRAC6 on Rack and Tower servers and is not displayed for iDRAC6 Enterprise on Blade servers If you run a deprecated command it works if the feature is supported If the feature is not supported an error is not returned If you run the racadm getconfig h command the deprecated group is not displayed in the results Deprecated Commands Groups and Objects 289 If you query a deprecated group or object then the values are returned If you try to configure a deprecated group or object the configuration succeeds If you request a group that contains a deprecated object the deprecated object is not displayed in the results Table 4 1 lists the RACADM subcommands deprecated in the current release Table 4 1 RACADM Deprecated Subcommands Subcommand Replaced With vmkey reset vflashsd initialize testkmsconnectivity Table 4 2 lists the RACADM groups and objects deprecated in the current release Table 4 2 RACADM Deprecated Gr
162. lity runs on the management station and the managed system It is available on the Dell OpenManage Systems Management and Documentation DVD or at support dell com The RACADM utility supports the following interfaces Local Supports executing RACADM commands from the managed server s operating system You must install the OpenManage software on the managed server to run local racadm commands Only one instance of local RACADM can be executed on a system at a time If the user tries to open another instance an error message is displayed and the second instance of local RACADM closes immediately SSH or Telnet Also referred as Firmware racadm Supports executing RACADM commands from a SSH or Telnet session to iDRAC Remote Supports executing RACADM commands from a remote management station such as a laptop or desktop computer You must install the OpenManage software on the remote computer to run remote RACADM commands To execute remote RACADM commands you must formulate the command like a local or SSH Telnet RACADM command except that you must also use the r options or the r u p options For more information on these options see the RACADM Subcommand Details on page 33 Introduction 23 RACADM Syntax Usage The following section describes the syntax usage for local SSH Telnet and Remote RACADM Local RACADM racadm getconfig g lt groupname gt o lt objectname gt i lt indexnumber gt
163. lityName Read Write Description Specifies the CSR Loyalty L Legal Values A string of up to 254 characters Default lt blank gt cfgRacSecCsrStateName Read Write Description Specifies the CSR State Name S Legal Values A string of up to 254 characters Default lt blank gt 282 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacSecCsrCountryCode Read Write Description Specifies the CSR Country Code CC Legal Values A string of up to 2 characters Default lt blank gt cfgRacSecCsrEmailAddr Read Write Description Specifies the CSR email address Legal Values A string of up to 254 characters Default lt blank gt Example racadm config g cfgRacSecurity cfgRacSecCsrKkeySize 1024 cfigRacSecCommonName cfgRacSecOrganizationName cfgRacSecOrganizationUnit cfgRacSecLocalityName cfgRacSecStateName cfgRacSecCount ryCode cfgRacSecEmailAddr cfgRacSecCsrKeySize Read Write Description Specifies the SSL asymmetric key size for the CSRs Legal Values 512 1024 2048 Default 1024 iDRAC6 and CMC Property Database Group and Object Descriptions 283 cfgRacSecurityData F NOTE This object property is specific to IDRAC6 only This group is used to configure settings related to iDRAC6 SSL certificate signing request CSR feature and KMC certificate signing request feature The properties in this group must be configured before generating a CSR from iDRAC6 This
164. lts to sslcsr in your current directory RACADM Subcommand Details 133 If no options are specified a CSR is generated and downloaded to the local file system as sslcsr by default The g option cannot be used with the s option and the f option can only be used with the g option The sslesrgen s subcommand returns one of the following status codes CSR was generated successfully CSR does not exist CSR generation in progress F NOTE Before a CSR can be generated the CSR fields must be configured in the RACADM cfgRacVirtual group For example racadm config g cfgRacSecurity o cfgRacSecCsrCommonName MyCompany F NOTE In telnet ssh console you can only generate and not download the CSR file Examples racadm sslcsrgen s OT racadm sslcsrgen g f c csr csrtest txt sslkeyupload F NOTE To use this subcommand you must have Configure iDRAC permission Subcommand Description sslkeyupload Uploads SSL key from the client to IDRAC6 Synopsis racadm sslkeyupload t lt type gt f lt filename gt 134 RACADM Subcommand Details Table 2 43 describes the sslkeyupload subcommand options Table 2 43 sslkeyupload Subcommand Options Option Description t Specifies the key to upload 1 SSL key used to generate the server certificate f Specifies the file name of the SSL key to be uploaded The sslkeyupload command returns 0 when successful and returns a nonzero numb
165. m of the firmware update file and starts the actual update process This option may be used along with the g or p options At the end of the update iDRAC6 performs a soft reset For CMC Performs the firmware update operation S For iDRAC The status option returns the current status of where you are in the update process This option is always used by itself For CMC Displays the current status of the firmware update NOTE Use m to display the status of the module update Omit m to display the status of the active CMC update NOTE The all value can only be used to obtain the status of all targets to be updated 56 RACADM Subcommand Details Table 2 11 fwupdate Subcommand Options continued Option Description 8 The get option instructs the firmware to get the firmware update file from the TFTP server You must also specify the a u and d options In the absence of the a option the defaults are read from properties contained in the group cfgRemoteHosts using properties cfgRhostsFwUpdatel pAddr and cfgRhostsFwUpdatePath For CMC Downloads the firmware update using the TFTP server a The IP Address option specifies the TFTP server IP address used with g option For CMC Specifies the TFTP server IP address or FQDN used for the firmware image used with g d For iDRAC The d or directory option specifies the directory on the TFTP server or on iDRAC6 s host server where
166. mand Details Synopsis racadm config cl p f lt filename gt racadm config g lt groupName gt o lt objectName gt i lt index gt lt Value gt F NOTE The configuration file retrieved using remote racadm and local racadm are notinteroperable The configuration file retrieved using remote racadm shows the index property for some of the indexed groups as read write for example cfgSSADRoleGrouplndex For the config f lt file name command use the configuration file retrieved from the same interface For example for local racadm config f lt file name gt use the file generated from the local racadm command getconfig f lt file name gt Input Table 2 3 describes the config subcommand options F NOTE The f and p options are not supported for the serial Telnet ssh console Table 2 3 config Subcommand Options and Descriptions Option Description f The f lt filename gt option causes config to read the contents of the file specified by lt filename gt and configure iDRAC6 The file must contain data in the format specified in the section Parsing Rules in the iDRAC6 User s Guide available on the Dell Support website at dell com support manuals p The p or password option directs config to delete the password entries contained in the config file f lt filename gt after the configuration is complete g The g lt groupName gt or group option must be used with the o option The lt
167. mation A do not show headers or labels 4 show CMC IPv4 information 6 show CMC IPv6 information help and help lt subcommand gt F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description help Lists all the subcommands available to use wth RACADM and provides a short description for each You may also type a subcommand after help to get the syntax for a specific subcommand Synopsis racadm help racadm help lt subcommand gt Output The racadm help command displays a complete list of subcommands The racadm help lt subcommand gt command displays information for the specified subcommand only 36 RACADM Subcommand Details arp F NOTE To use this subcommand you must have Administrator and Execute Diagnostic Commands permission Subcommand Description arp Displays the contents of the Address Resolution Protocol ARP table ARP table entries cannot be added or deleted Synopsis racadm arp Example For rack and tower servers adminl gt racadm arp Address HWtype HWaddress Flags Mask Iface 10 94 161 1 ether OO0 0F F7 2C 1C C4 2 etho For blade servers racadm arp Address HWtype Flags HWaddress Mask Device 10 94 161 1 Oxl 0x2 OO 0F F7 2C 1C C4 eth0 chassisaction IP Address HW Type Flags HW Address Mask Device 192 168 1 1 0x1 0x2 00 00 0C 07 AC 0F eth0 RACADM Subcommand Details 37 F NOTE To use this
168. mmand Details Table 2 15 describes the getflexaddr subcommand options Table 2 15 getflexaddr Subcommand Options Option Description i lt slotNum gt Specifies the slot information to be displayed lt slotNum gt can be from 1 to 16 Example Display current flex address settings for all slots and fabrics racadm getflexaddr lt Slot gt J F VO OQ IN OU BUY N PP re Be HA HA O oO AeA W N EBE Oo Status Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl Enabl ed ed ed ed ed ed ed ed ed ed ed ed ed ed ed ed lt Server Presence gt Present Present ot Presen ot Presen Present ot Presen ot Presen ot Presen ot Present Extension ot Presen ot Presen Extension ot Present ot Presen ot Presen RACADM Subcommand Details 67 lt Fabric gt lt Type gt lt Status gt A Gigabit Ethernet Enabled B None Enabled C None Enabled idrac Management Controller Disabled Display the current flex address setting for slot 1 racadm getflexaddr i 1 Slot 1l server presence Present Slot 1 flexaddress enabled 1 lt Fabric gt lt Type gt lt Server Assigned gt lt Chassis Assigned gt slot1 A1 Gigabit 00 1C 23 CD AC D2 00 1E C9 FF E3 21 Ethernet active iSCSI 00 1C 23 CD AC D3 00 1E C9 FF E3 22 active slot1 A2 Gigabit 00 1C 23 CD AC D4 00 1E C9
169. must be empty Create an empty partition The following options are valid with the empty type s lt size gt Partition size in MB f lt type gt Format type for the partition based on the type of file system Valid options are RAW FAT16 FAT32 EXT2 or EXT3 image Create a partition using an image relative to iDRAC The following options are valid with the image type lt path gt Specifies the remote path relative to iDRAC The path can be on a mounted drive SMB path lt ip or domain gt lt share_name gt lt path_to_image gt NFS path lt ipaddress gt lt path_to_image gt u lt user gt Username for accessing the remote image p lt password gt Password for accessing the remote image Options valid only with status action a Displays the status of operations on all existing partitions Examples To create a 20MB empty partition racadm vflashpartition create i 1 o drivel t mpty HDD f fatl6 s 20 To create a partition using an image file on a remote system racadm vflashpartition create i 1 o drivel e HDD t image l myserver sharedfolder foo iso u root p mypassword NOTE This command is case sensitive for the image file name extension If the file name extension is in upper case for example FOO ISO instead of FOO iso then the command returns a syntax error To delete a partition racadm vflashpartition delete i 1
170. nd is successful it is recommended to use the cfgVF lashSDWriteProtect command For more information see cfg VFlashSDWriteProtect Read Only on page 277 1 TRUE 0 FALSE 0 cfgLCDriveEnable Read Write Description Legal Values Default Enable disable the USC LCE device from showing up in the operating system It must be disabled in ESXi operating system Allows proper operation of operating system and drivers interfacing with the iDRAC USC LCE USB devices 1 Enabled 0 Disabled l iDRAC6 and CMC Property Database Group and Object Descriptions 201 cfgServerlnfo This group allows you to select the BIOS first boot device and to boot the selected device only once For CMC this group allows you to displays information for and configure a server in the chassis F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option The following sections provide information about the objects in the cfgServerlnfo group cfgServerlnfolndex Read only F NOTE This object is applicable only to CMC Description Displays the index name of the server Legal Values None Default None cfgServerSlotNumber Read only F NOTE This object is appl
171. ndex of an alert instance Legal Values 1 4 Default lt instance gt 176 iDRAC6 and CMC Property Database Group and Object Descriptions cfgEmailAlertEnable Read Write Description Enables or disables the alert instance Legal Values 1 TRUE 0 FALSE Default 0 cfgEmailAlertAddress Read Write Description Specifies the destination email address for email alerts for example user company com Legal Values E mail address format with a maximum length of 64 ASCII characters Default lt blank gt cfgEmailAlertCustomMsg Read Write F NOTE This object property is specific to iDRAC6 Description Specifies a custom message that forms the subject of the alert Legal Values A string of up to 32 characters Default lt blank gt cfgEmailAlertEmailName F NOTE This object property is specific to CMC Description Specifies name or other identifier associated with the destination e mail address The e mail name can refer to an individual group location department etc Legal Values A string of up to 32 characters Default lt blank gt iDRAC6 and CMC Property Database Group and Object Descriptions 177 Example racadm getconfig g cfgEmailAlert i 2 cfgEmailAlertIndex l cfgEmailAlertEnable 1 cfgEmailAlertAddress kfulton dell com cfgEmailAlertName Kevin Fulton cfgSessionManagement This group contains parameters to configure the number of sessions that can connect
172. nfigDisable Read Write F NOTE This object property is applicable only to iDRAC6 Description Disables write access to iDRAC6 configuration data by setting to 1 NOTE Access can be disabled using the local RACADM or iDRAC6 Web interface however once disabled access can be re enabled only through iDRAC6 Web interface Legal Values 0 TRUE Enables 1 FALSE Disables Default 0 cfgRacTuneWebserverEnable Read Write Description Enables or disables iDRAC6 or CMC web server If this property is disabled iDRAC6 or CMC is not accessible using client web browsers This property has no effect on the Telnet SSH or RACADM interfaces Legal Values 1 TRUE 0 FALSE Default l 196 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRacTuneVirtualConsoleAuthorizeMultipleSessions Read Write F NOTE This object property is applicable only to iDRAC6 F NOTE To modify this property you must have Configure iDRAC permission This object can be used only with remote or firmware SSH or Telnet RACADM and not with local RACADM or with earlier DRAC products F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and notfor iDRAC6 Enterprise on Blade Servers Description If a first user is already using the Virtual Console the value of this object effects the privileges granted to the subsequent user s shared request after the timeout of 30 seconds Legal Values 0 If the user of the first s
173. ng sections provides information about the objects in the cfgStandardSchema group cfgSSADRoleGrouplndex Read Only Description Index of the Role Group as recorded in the Active Directory Legal Values An integer between and 5 Default lt instance gt iDRAC6 and CMC Property Database Group and Object Descriptions 223 cfgSSADRoleGroupName Read Write Description Name of the Role Group as recorded in the Active Directory forest Legal Values Any printable text string of up to 254 characters with no white space Default lt blank gt cfgSSADRoleGroupDomain Read Write Description Active Directory Domain in which the Role Group resides Legal Values Any printable text string of up to 254 characters with no white space Default lt blank gt cfgSSADRoleGroupPrivilege Read Write Description Use the bit mask numbers in Table 3 5 to set role based authority privileges for a Role Group Legal Values For iDRAC6 0x00000000 to 0x000001 ff For CMC 0x00000000 0x00000Ffff Default lt blank gt Example racadm getconfig g cfgStandardSchema cfgSSADRoleGroupIndex 1 cfgSSADRoleGroupName blsys 1 cfgSSADRoleGroupDomain cfgSSADRolGroupPrivilege 3081 Table 3 5 displays the bit masks for Role Group privileges Table 3 5 Bit Masks for Role Group Privileges Role Group Privilege Bit Mask Login to iDRAC 0x00000001 Configure iDRAC 0x00000002 224 iDRAC6 and CMC Property Database Group and Object Descr
174. ntServer2 Displays the IP address for DNS server 2 cfgDNSCurrentDomainName Displays the DNS domain name 264 iDRAC6 and CMC Property Database Group and Object Descriptions cfgNicCurrentiPv4Enabled Indicates whether IPv4 is enabled on the CMC If the current property value is set to 0 false the remote network interfaces to the CMC are not accessible over IPv4 Example racadm getconfig g cfgCurrentLanNetworking cfgNicCurrentIPv4Enabled 1 cfgNicCurrent IpAddress 143 166 152 116 cfgNicCurrentNetmask 255 255 255 0 cfgNicCurrentGateway 143 166 152 1 cfgNicCurrentDhcpWasUsed 0 cfgNicCurrentVlanEnable 0 cfgNicCurrentVlanID 1 cfgNicCurrentVlanPriority 0 cfgDNSCurrentServer1l 192 168 0 5 cfgDNSCurrentServer2 192 168 0 6 cfgDNSCurrentDomainName MYDOMAIN cfgCurrentIPv6LanNetworking Read only This group displays the current CMC IPv6 properties F NOTE This object property is applicable only for CMC Use this object with the getconfig subcommand F NOTE To use this object property you must have CMC Login User privilege cfgCurrentIPv6Enabled Indicates whether IPv6 is enabled on the CMC If the current property value is set to 0 false the remote network interfaces to the CMC are not accessible over IPv6 iDRAC6 and CMC Property Database Group and Object Descriptions 265 cfgCurrentlPv6AutoConfigWasUsed Description Indicates whether auto configuration is used to obtain IPv6
175. o use this subcommand you must have Clear Logs permission Subcommand Description clrraclog Removes all existing records from iDRAC6 log A new single record is created to record the date and time when the log was cleared Synopsis racadm clrraclog clrsel F NOTE To use this subcommand you must have Clear Logs permission Subcommand Description clrsel Removes all existing records from the System Event Log SEL Synopsis racadm clrsel RACADM Subcommand Details 41 cmcchangeover F NOTE To use this subcommand you must have Administrator privilege Subcommand Description cmcchangeover Changes the state of the CMC from active to standby or vice versa in a redundant CMC configuration This subcommand is useful for remote debugging or testing purposes F NOTE This command is valid only in redundant CMC environments For more information see the Understanding the Redundant CMC Environment section of the Dell Chassis Management Controller User Guide Synopsis racadm cmcchangeover Output CMC failover initiated successfully config F NOTE To use this subcommand you must have Log In iDRAC permission Subcommand Description config This subcommand allows you to set iDRAC6 configuration parameters individually or to batch them as part of a configuration file If the data is different that iDRAC6 object is written with the new value 42 RACADM Subcom
176. ogin privilege Subcommand Description getversion Displays the current software version model and generation information and whether or not the target device can be updated Synopsis racadm getversion b c m lt module gt racadm getversion 1 m lt module gt f lt filter gt racadm getversion Table 2 26 describes the getversion subcommand options Table 2 26 getversion Subcommand Options Option Description none Displays the version information for all targets or devices m Specifies the module or device for which you want to retrieve the lt module gt version information lt module gt is one of the following server n where n 1 16 For example server 1 cmc n where n or 2 For example cmc 2 C Displays the server s current CPLD version b Displays the server s current BIOS version default is IDRAC version l Displays the firmware versions of available server components RACADM Subcommand Details 101 Table 2 26 getversion Subcommand Options continued Option Description f lt filter gt Filters the components Must be used with l and be one of the following values bios BIOS idrac iDRAC usc Lifecycle Controller Unified Server Configurator diag 32 bit Diagnostics drivers OS Driver Package nic x Network Interface card See l output for possible values of x raid x Raid Controller See l output for possi
177. old in Watts cfgServerPowerCapBtuhr Read Write F NOTE This object is applicable only for iDRAC6 Description Represents the server power threshold in BTU hr Legal Values A string of up to 32 characters Default Server power threshold in BTU hr cfgServerPowerCapPercent Read Write F NOTE This object is applicable only for iDRAC6 Description Represents the server power threshold in percentage Legal Values A string of up to 32 characters Default Server power threshold in percentage iDRAC6 and CMC Property Database Group and Object Descriptions 241 cfgServerPowerLastMinAvg Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the average power value during the last minute Legal Values A string of up to 32 characters Default Average power value during the last minute cfgServerPowerLastHourAvg Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the average power value during the last hour Legal Values A string of up to 32 characters Default Average power value during the last hour cfgServerPowerLastDayAvg Read Only F NOTE This object is applicable only for iDRAC6 Description Displays the average power value during the last day Legal Values A string of up to 32 characters Default Average power value during the last day cfgServerPowerLastWeekAvg Read Only F NOTE This object is applicable only for iDRAC6 Description D
178. oller1 cfgAdDomainController2 and cfgAdDomainController3 iDRAC6 does not fail over to the specified domain controllers when DNS lookup fails or none of the servers returned by the DNS lookup works Legal Values 1 TRUE use DNS to look up domain controllers 0 FALSE use pre configured domain controllers Default 0 cfgADDcSRVLookupbyUserdomain Read Write F NOTE This object is applicable only to iDRAC6 Description Chooses the way the user domain is looked up for Active Directory Legal Values 1 TRUE use user domain as the search domain to look up DCs The user domain is chosen from the user domain list or entered by the login user 0 FALSE use the configured search domain cfgADDcSrvLookupDomainName to look up DCs Default l iDRAC6 and CMC Property Database Group and Object Descriptions 215 cfgADDcSRVLookupDomainName Read Write F NOTE This object is applicable only to iDRAC6 Description This is the Active Directory Domain to use when cfgAddcSzyLookupbyUserDomain is set to 0 Legal Values String Maximum length 254 Default Null cfgADGcSRVLookupEnable Read Write F NOTE This object is applicable only to iDRAC6 Description Determines how the global catalog server is looked up If using pre configured global catalog servers then iDRAC6 uses the values cfgAdGlobalCatalog1 cfgAdGlobalCatalog2 and cfgAdGlobalCatalog3 Legal Values 0 FALSE use pre configured Global Catalog Servers GCS 1 T
179. ommand Description getsvctag Displays the service tag of the host system Synopsis racadm getsvctag Example Type get svctag at the command prompt The output is displayed as follows Y76TPOG 94 RACADM Subcommand Details getsysinfo F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description getsysinfo Displays information related to IDRAC managed system and watchdog configuration F NOTE The local racadm getsysinfo subcommand on Linux displays the PrefixLength on separate lines for IPv6 Address 2 IPv6 Address 15 and the Link Local Address Synopsis racadm getsysinfo d s w A c 4 6 Table 2 24 describes the getsysinfo subcommand options Table 2 24 getsysinfo Subcommand Options Option Description 4 Di 6 Di c Di splays IPv4 settings splays IPv6 settings a plays common settings d Displays iDRAC6 information s Displays system information w Displays watchdog information A Eliminates the printing of headers labels If the w option is not specified then the other options are used as defaults Sample Output RAC Information 10 27 2009 14 38 00 L230 20 RAC Date Time Firmware Version Firmware Build RACADM Subcommand Details 95 Last Firmware Update Hardware Version MAC Address Common settings Register DNS RAC Name DNS RAC Name Cur
180. ookupServiceName cfgLdapRoleGroup cfgLdapRoleGroupIndex Read Only cfgLdapRoleGroupDN Read Write cfgLdapRoleGroupPrivilege Read Write cfgStandardSchema cfgSSADRoleGroupIndex Read Only cfgSSADRoleGroupName Read Write cfgSSADRoleGroupDomain Read Write cfgSSADRoleGroupPrivilege Read Write cfgChassisPower cfgChassisInPower Read Only cfgChassisPeakPower Read Only cfgChassisPeakPowerTimestamp Read Only cfgChassisMinPower Read Only cfgChassisMinPowerTimestamp Read Only Contents 13 14 Contents cfgChassisPowerStatus Read Only cfgChassisRedundantState Read Only cfgChassisPowerCap Read Write cfgChassisPowerCapF Read Write cfgChassisPowerCapBTU Read Write cfgChassisPowerCapFBTU Read Write cfgChassisPowerCapPercent Read Write cfgChassisPowerCapFPercent Read Write cfgChassisRedundancyPolicy Read Write cfgChassisDynamicPSUEngagementEnable Read Write cfgChassisAllow110VACOperation Read Write cfgChassisMaxPowerConservationMode Read Write cfgChassisPerformanceOverRedundancy Read Write cfgChassisInMaxPowerCapacity Read Only cfgChassisInRedundancyReserve Read Only cfgChassisInPowerServer
181. opsis racadm racdump Example racadm racdump General System RAC Information CMC Information CMC Date Time Wed 28 Nov 2007 11 55 49 PM Active CMC Version X08 Standby CMC Version N A Last Firmware Update Wed Nov 21 21 37 56 2007 Hardware Version 2 Current IP Address 10 35 155 160 Current IP Gateway 10 39 2505 Current IP Netmask 255 255 255 0 DHCP Enabled 1 AC Address 00 55 AB 39 10 0F Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP Register DNS CMC Name DNS CMC Name cmc servicetag Current DNS Domain 0 0 0 0 0 0 O O OO Chassis Information System Model PowerEdgeM1000eControlPanel 110 RACADM Subcommand Details System AssetTag Service Tag Chassis Name Chassis Location Power Status 00000 Dell Rac UNDEFINED ON k System Session Information Type SSH KVM User root root IP Address 10972 252 169 254 31 30 Login Date Time 11 28 2007 23 40 53 11 28 2007 18 44 51 Sensor Information lt senType gt lt Num gt lt sensorName gt status reading lt units gt lt lc gt Fans Fans Fans Fans Fans Fans Fans Fans Fans lt senType gt lt Num gt lt sensorName gt lt status gt lt reading gt Temp peed peed peed peed peed peed peed peed peed 1 Oo OA DH BUL N
182. oups and Objects Group Object Replaced With cfgVirMediaKeyEnable cfgVFlashSDEnable cfgSDWriteProtect cfgVFlashSDWriteProtect 290 Deprecated Commands Groups and Objects Index C community string SNMP 234 D Deprecated commands and objects 289 P property database groups cfgActiveDirectory 209 cfgAlerting 253 cfgChassisPower 225 cfgCurrentLanNetworking 264 cfgEmailAlert 176 cfgIpmiLan 233 cfgIpmiPef 235 cfgIpmiPet 237 cfglpmiSerial 267 271 cfgIpmiSol 232 cfgKVMInfo 252 cfgLanNetworking 156 cfgNetluning 272 cfgRacSecurity 281 cfgRacTuning 189 cfgRacVirtual 199 cfgSerial 181 cfgSessionManagement 178 cfgTraps 187 cfgUserAdmin 171 idRaclnfo 154 ifcRacManagedNodesOs 198 RACADM supported interfaces 23 RACADM subcommands 34 arp 37 chassisaction 37 clearasrscreen 39 clrraclog 1 clrsel 41 cmechangeover 42 config 42 connect 45 coredump 46 47 coredumpdelete 47 deploy 47 feature 50 featurecard 52 fwupdate 54 getassettag 61 getchassisname 61 getconfig 62 getdcinto 64 getflexaddr 66 getiointo 71 getkvminfo 72 Index 291 292 getled 73 getmacaddress 74 getmodinfo 79 getniccfg 81 getpbinfo 83 getpminfo 85 getraclog 86 getractime 87 getredundancymode 88 getsel 89 getsensorinfo 90 getslotname 91 getssninfo 93 getsvctag 94 getsysinfo 95 gettracelog 99 getversion 100 101 help 36 ifconfig 104 localCon
183. ower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC For iDRAC6 on Rack and Tower Servers the object is available only under Modular FW and Remote RACADM and notin Local RACADM Description Represents the available allocated power supply for server usage NOTE In case of more than one power supply this object represents the minimum capacity power supply Legal Values A string of up to 32 characters Default lt blank gt cfgServerActualPowerConsumption Read Only F NOTE This object is applicable only for iDRAC6 Description Represents the power consumed by the server at the current time Legal Values A string of up to 32 characters Default lt blank gt cfgServerPowerCapEnable Read Only F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Enables or disables the user specified power budget threshold Legal Values 0 Disables the user specified power budget threshold l Enables the user specified power budget threshold Default l iDRAC6 and CMC Property Database Group and Object Descriptions 239 cfgServerMinPowerCapacity Read Only F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Represents the minimum server power capacity Legal Values A string of up to 32 characters Default lt blank gt cfgServerMaxP
184. owerCapacity Read Only F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description Represents the maximum server power capacity Legal Values A string of up to 32 characters Default lt blank gt cfgServerPeakPowerConsumption Read Only F NOTE This object is applicable only for iDRAC6 Description Represents the maximum power consumed by the server until the Current time Legal Values A string of up to 32 characters Default current server peak power consumption gt peak p P cfgServerPeakPowerConsumptionTimestamp Read Only F NOTE This object is applicable only for iDRAC6 Description Time when the maximum power consumption was recorded Legal Values A string of up to 32 characters Default Maximum power consumption timestamp 240 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerConsumptionClear Write Only F NOTE This object is applicable only for iDRAC6 Description Resets the cfeServerPeakPowerConsumption Read Write property to 0 and the cfgServerPeakPowerConsumption Timestamp property to the current iDRAC time Legal Values 1 TRUE 0 FALSE Default None cfgServerPowerCapWatts Read Write F NOTE This object is applicable only for iDRAC6 Description Represents the server power threshold in Watts Legal Values A string of up to 32 characters Default Server power thresh
185. r CMC Description Legal Values Default Specifies the third of three possible NTP servers A string representing a valid NTP server For example ntp3 ntp net At least one NTP server must be specified and duplicate entries are not allowed Null iDRAC6 and CMC Property Database Group and Object Descriptions 167 cfgRhostsNtpMaxDist F NOTE This object is applicable only for CMC Description Specifies the NTP maximum distance parameter used to aid in NTP configuration Legal Values 1 128 Default 16 cfgRhostsSyslogEnable Read Write Description Enables or disables remote syslog to allow the RAC and SEL logs to be written to up to three remote syslog servers Legal Values 1 TRUE 0 FALSE Default 0 cfgRhostsSyslogPort Read Write Description Remote syslog port number to use for writing the RAC and SEL logs to a remote syslog server For CMC this setting takes effect only if the cfgRhostsSyslogEnable parameter is set to 1 enabled Legal Values 10 65535 Default 514 F NOTE For CMC the following port numbers are reserved and cannot be used 21 68 69 123 161 546 801 4096 5988 5989 6900 9000 60106 168 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRhostsSyslogServer1 Read Write Description Legal Values Default Specifies the first of three possible remote syslog servers to store the RAC and SEL logs This property is only valid if cfgRhostsSyslogEn
186. racelog The gettracelog sub command lists all the trace log entries in the DRAC Table 2 25 lists the gettracelog options used to read entries Table 2 25 gettracelog Subcommand options Option Description i Displays the number of entries in iDRAC6 trace log m Displays one screen at a time and prompts the user to continue similar to the UNIX more command 0 Displays each entry in a single line C Specifies the number of records to display S Specifies the starting record to display A Do not display headers or labels Synopsis racadm gettracelog i A racadm gettracelog s lt start gt c lt count gt m A o RACADM Subcommand Details 99 Output The default output display shows the record number timestamp source and description The timestamp begins at midnight January 1 and increases until the system boots After the system boots the system s timestamp is used For example Record 1 Date Time Dec 8 08 21 30 Source ssnmgrd 175 Description root from 143 166 157 103 session timeout sid Obe0aef4 getuscversion F NOTE This option is applicable only for iDRAC6 Subcommand Description getuscversion Displays the current USC software version details in iDRAC Synopsis racadm getuscversion Example racadm getuscversion 1 2 3 4 100 RACADM Subcommand Details getversion F NOTE To use this subcommand you must have L
187. re cfgUserAdminEnable Read Write Description Enables or disables an individual user Legal Values 1 TRUE 0 FALSE Default For iDRAC6 1 User 2 0 All others For CMC 0 cfgUserAdminSolEnable Read Write F NOTE This object property is specific to iDRACE Description Enables or disables Serial Over LAN SOL user access for the user Legal Values 1 TRUE 0 FALSE Default 0 iDRAC6 and CMC Property Database Group and Object Descriptions 175 cfgUserAdminlpmiSerialPrivilege Read Write F NOTE This object is applicable only for iDRAC6 on Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC Description The maximum privilege on the IPMI LAN channel Legal Values 2 User 3 Operator 4 Administrator 15 No access Default 4 User 2 15 All others cfgEmailAlert This group contains parameters to configure iDRAC6 or CMC e mail alerting capabilities Up to four instances of this group are allowed F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privileges F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option The following sections provides information about the objects in the cfgEmailAlert group cfgEmailAlertlndex Read Only Description The unique i
188. release does not support this group This group is applicable only for iDRAC6 and is an indexed group which currently only supports two indices since iDRAC only communicates with any one of the two KMSs using their specific profile information F NOTE This group is also configurable using the f option and follows the read only value of cfgKMSProfilelndex as the anchor value for the indexed group The following section provides information about the objects in the cfgKMSProfile group cfgKMSProfilelndex Read only Description Index of the profile Legal Values l 2 Default None cfgKMSProfilelPAddress Read Write Description IP address FQDN of the KMS Legal Values IPv4 IPv6 FODN Default 0 0 0 0 cfgKMSProfilePortNumber Read Write Description Port number indicates the port on which the Key management server is listening to For KMC to communicate to the KMS one needs to configure the same port number as on the KMS Legal Values 1 to 65535 Default 443 280 iDRAC6 and CMC Property Database Group and Object Descriptions cfgKMSProfileTimeout Read Write Description The timeout value indicates the keep alive time for the KMC KMS connection Legal Values 15 to 600 seconds Default 300 seconds cfgKMSProfileDeviceGroup Read Write Description Device group indicates the group on the KMS to which the device will belong to The Device group on the KMS is a configurable string which must be provided to the KMC for it to
189. rent DNS Domain Domain Name from DHCP IPv4 settings Enabled Current IP Address Current IP Gateway Current IP Netmask DHCP Enabled Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP IPv6 settings Enabled Current IP Address 1 Current IP Gateway Autoconfig Link Local IP Address Current IP Address 2 Current IP Address 3 Current IP Address 4 96 RACADM Subcommand Details 10 26 2009 16 55 08 0 01 00 24 e8 2e c5 d3 1 eval710 08 r blr amer dell com 1 10 94 20 134 10 94 20 1 2554255254 0 163 244 180 39 163 244 180 40 J fe80 224 e8ff fe2e c5d3 255 Current IP Address 5 Current IP Address 6 Current IP Address 7 Current IP Address 8 Current IP Address 9 Current IP Address Current IP Address Current IP Address Current IP Address Current IP Address Current IP Address DNS Servers from DHCPv6 Current DNS Server Current DNS Server 2 System Information System Model System BIOS Version Service Tag OS Name Microsoft Windows Server 2008 Edition x64 Express Svc Code Host Name System Revision NIC1 power Status Ethernet iSCSI 0 1 12 3 4 15 PowerEdge R710 1 0 4 2X2012S 39059052868 WIN IHFS5D2BE5SN ON Embedded NIC MAC Addresses 00 24 e8 2e c5 cb 00 24 e8 2e c5 cc RACADM Subcommand Details Enterprise 97 NIC2 Ethernet 00 24 e8 2e c5 iSCSI 00 24 e8 2e c5
190. rise on Blade Servers iDRAC6 Log entries for SystemBoot displayed using the local racadm command racadm getraclog may not be correctly formatted For example some extra characters may be displayed in the Description field or the Source field may be empty Sample Output Record 1 Date Time Dec 8 08 10 11 Source login 433 Description root login from 143 166 157 103 getractime F NOTE To use this subcommand you must have Login to iDRAC permission Subcommand Description getractime The getractime subcommand displays the current DRAC time Table 2 20 lists the options that allow the getractime command to display the time in specific formats RACADM Subcommand Details 87 Table 2 20 getractime Subcommand Options Option Description d Displays the time in the format yyyymmddhhmmss mmmmmms Z Displays timezone NOTE This option is specific to CMC only n Displays NTP peer information NOTE This option is specific to CMC only K NOTE If no options are provided the getractime subcommand displays the time in a common readable format Synopsis racadm getractime d racadm getractime d z n Sample Output racadm getractime Thu Dec 8 20 15 26 2005 racadm getractime qd 20051208201542 000000 getredundancymode F NOTE To use this subcommand you must have CMC Login User privilege Subcommand Description getredundancy Displays the redundancy status
191. rite 211 cfgADDomainController 211 cfgADDomainController1 Read Write 211 cfgADDomainController2 Read Write 212 cfgADDomainController3 Read Write 212 cfgADAuthTimeout Read Write 212 cfgADType Read Write aaa 212 cfgADSpecifyServerEnable 213 cfgADGlobalCatalog aaa aaa aaa 213 cfgADGlobalCatalog1 Read Write 214 cfgADGlobalCatalog2 Read Write 214 cfgADGlobalCatalog3 Read Write 214 cfgADCertValidationEnable Read Write 215 cfgADDcSRVLookupEnable Read Write 215 cfgADDcSRVLookupbyUserdomain Read Write 215 cfgADDcSRVLookupDomainName Read Write 216 cfgADGcSRVLookupEnable Read Write 216 cfgADGcRootDomain Read Write 216 CIGLDAP se OR OE EE ON 216 12 Contents cfgLdapEnable Read Write aa cfgLdapServer Read Write cfgLdapPort Read Write cfgLdapBasedn Read Write cfgLdapUserAttribute Read Write cfgLdapGroupAttribute Read Write cfgLdapGroupAttributelsDN Read Write cfgLdapBinddn Read Write cfgLdapBindpassword Write only cfgLdapSearchFilter Read Write cfgLDAPCertValidationEnable Read Write cfgLDAPNetworkTimeout cfgLDAPSearchTimeout cfgLDAPSRVLookupEnable cfgLDAPSRVLookupDomainName cfgLDAPSRVL
192. rite Description Legal Values Default F NOTE Virtual Media has to be reattached using cfgVirMediaAttached for this change to take effect When set to 0 the virtual floppy drive is recognized as a removable disk by Windows operating systems Windows operating systems assigns a drive letter that is C or higher during enumeration When set to 1 the Virtual Floppy drive is seen as a floppy drive by Windows operating systems Windows operating systems assigns a drive letter of A or B 1 TRUE 0 FALSE 0 cfgVirMediaKeyEnable Read Write 200 Description Legal Values Default Enables or disables the Virtual Media key feature of the RAC NOTE This command is deprecated from 1 5 and 3 0 releases onwards The functionality of this command is now covered by cfgVFlashSDEnable While execution of the cfgVirMediaKeyEnable command is successful it is recommended to use the cfgVF1ashSDEnable command For more information see cfgVFlashSDEnable Read Write on page 275 1 TRUE 0 FALSE 0 iDRAC6 and CMC Property Database Group and Object Descriptions cfgSDWriteProtect Read only Description Legal Values Default Displays if the physical write protect latch on the SD card is enabled or disabled NOTE This command is deprecated from 1 5 and 3 0 releases onwards The functionality of this command is now covered by cfgVFlashSDWriteProtect While execution of the cfgSDWriteProtect comma
193. ry For example 2001 DB8 1234 5678 9ABC DE 1 1 C00C BEEF Default Example racadm getconfig g cfgIPv6LanNetworking lt n gt cfgIPv6 Enable 1 cfgIPv AutoConfig 1 cfgIPv Address cfgIPv 6 PrefixLength 64 cfgIPv6 Gateway cfgIPv6 DNSServersFromDHCP6 1 cfgIPv 6 DNSServerl cfgIPv 6 DNSServer2 If both IPv4 and IPv6 are enabled on the CMC IPv6 DNS servers take priority The order of preference for DNS servers is cfgIPv6DNSServer1 cfgIPv6DNSServer2 cfgDNSServer cfgDNSServer2 iDRAC6 and CMC Property Database Group and Object Descriptions m server 263 cfgCurrentLanNetworking Read only This group displays the current CMC NIC properties F NOTE This object property is applicable only for CMC Use this object with the getconfig subcommand F NOTE To use this object property you must have CMC Login User privilege Synopsis racadm getconfig g cfgCurrentlanNetworking cfgNicCurrentlpAddress Displays the static IP address to the CMC cfgNicCurrentNetmask Displays the static subnet mask for the CMC IP address cfgNicCurrentGateway Displays the static gateway for the CMC IP address cfgNicCurrentDhcpWasUsed Description Indicates whether DHCP is used to configure the NIC Legal Values 0 address is static address was obtained from the DHCP server Default None cfgDNSCurrentServer1 Displays the IP address for DNS server 1 cfgDNSCurre
194. s Legal Values A string of up to 64 characters Default If the card is not initialized default is 0 If initialized displays the unused space on the card cfgVFlashSDHealth Read Only Description Displays the current health status of the vFlash SD card Legal Values String OK Warning Critical e Unknown Default OK 276 iDRAC6 and CMC Property Database Group and Object Descriptions cfgVFlashSDWriteProtect Read Only Description Displays whether the physical write protect latch on the vFlash SD card is enabled or disabled Legal Values 0 vFlash is not write protected 1 vFlash is write protected Default None cfgVFlashPartition This group is applicable only for iDRAC6 and is used to configure properties for individual partitions on the vF lash SD Card Up to 16 partitions are supported indexed from to 16 F NOTE For SD cards the index value is limited to 1 because only a single partition of size 256 MB is allowed The following sections provides information about the objects in the cfgVFlashPartition group cfgVFlashPartitionIndex ReadOnly Description Displays the size of the partition Legal Values Integer from 1 16 Default None cfgVFlashPartitionSize ReadOnly Description The index value of the partition Legal Values 1MB to 4 GB Default None iDRAC6 and CMC Property Database Group and Object Descriptions 277 cfgVFlashPartitionEmulationType ReadWrite Description Disp
195. s are unable to report the server s DC fabric type The DC fabric type may not be reported in the CMC user interface until iDRAC on the server is powered on Synopsis racadm getdcinfo Table 2 14 describes the getdcinfo subcommand options Table 2 14 getdcinfo Subcommand Options Option Description n Displays the model names for the daughter cards in servers 64 RACADM Subcommand Details Example The example output below is for a system with multi slot servers racadm getdcinfo Group A I O Type Gigabit Ethernet Group B I O Type Gigabit Ethernet Group C I O Type Gigabit Ethernet lt IO gt lt Type gt lt State gt lt Role gt switch 1 Gigabit Ethernet OK Master switch 2 None N A N A switch 3 Gigabit Ethernet OK Master switch 4 None N A N A switch 5 Gigabit Ethernet OK Member switch 6 None N A N A lt Server gt lt Presence gt lt DC1 Type lt DC1 lt DC2 Type gt lt DC2 State gt State gt server 1 Present None N A None N A server 2 Not Present None N A None N A server 3 Not Present None N A None N A server 4 Present None N A Gigabit OK Ethernet server 5 Not Present None N A None N A server 6 Not Present None N A None N A server 7 Not Present None N A None N A server 8 Present FibreChannel 4 Invalid None N A server 9 Extension 1 None N A None N A server 10 Not Present None N A None N A server 1l Not Present None N A None N A server 12 Not Present None N A None N
196. sables the RAC or CMC serial console login authentication Legal Values 0 enables serial login authentication 1 disables serial login authentication Default 0 cfgSerialConsoleCommand Read Write Description Specifies a serial command that is executed after a user logs into the serial console interface Legal Values For iDRAC6 A string of up to 128 characters For CMC A string representing a valid serial command For example connect server l Default lt blank gt cfgSerialConsoleColumns F NOTE This object property is applicable only for CMC Description Specifies the number of columns in the terminal window command line connected to the serial port Legal Values 0 256 Default 0 equivalent to 80 184 iDRAC6 and CMC Property Database Group and Object Descriptions F NOTE The prompt counts as two characters F NOTE The terminal emulator must be configured with the line wrap mode ON if a terminal emulator is used F NOTE You must log out then log in again for the changes to take effect cfgSerialHistorySize Read Write Description Specifies the maximum size of the serial history buffer Legal Values 0 8192 Default 8192 cfgSerialCom2RedirEnable Read Write F The cfgSerialCom2RedirEnable object property is applicable only for iDRAC6 on Rack and Tower Servers It is not applicable for iDRAC6 Enterprise on Blade Servers and CMC Description Enables or disables the console for COM 2 port
197. seDN The search filter only applies to userDN search and not the group membership search Legal Values For iDRAC6 String of maximum length 254 characters For CMC String of maximum length 1024 characters Default objectclass Searches for all objects in tree cfgLDAPCertValidationEnable Read Write Description Controls certificate validation during SSL handshake Legal Values 1 TRUE iDRAC6 or CMC uses the CA certificate to validate the LDAP server certificate during SSL handshake 0 FALSE iDRAC6 or CMC skips the certificate validation step of SSL handshake Default l cfgLDAPNetworkTimeout K NOTE This object is applicable only to CMC Description Configures the network timeout in seconds Legal Values Positive integer Default 30 seconds cfgLDAPSearchTimeout F NOTE This object is applicable only to CMC Description Configures the search timeout in seconds Legal Values Positive integer Default 120 seconds 220 iDRAC6 and CMC Property Database Group and Object Descriptions cfgLDAPSRVLookupEnable F NOTE This object is applicable only to CMC Description Configures the CMC to query a DNS server for SRV records Legal Values true 0 false Default 0 cfgLDAPSRVLookupDomainName F NOTE This object is applicable only to CMC Description Configures the domain name to be used in the SRV lookup Legal Values String of maximum length of 254 alphanumeric characters and hyphens The string
198. sent lt BMC MAC Address gt N A OO 1E AF 2A AF 7B 00 22 19 D2 1E 84 RACADM Subcommand Details lt NIC1 MAC Address gt OO 1E 4F 1F 3C 58 OO 1E AF 2A D3 297 N A lt NIC2 MAC Address gt N A OO 1E AF 2A D3 99 N A 75 Server 3 Server 4 Server 5 Server 6 Server 7 Server 8 Server 9 Server Server Server Server Server Server Server Switch Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Not Present Present Present Present Present Not Present Not Present Not Present Not Present Not Present Present Present Extension 7 Not Present Present Present Present Present Present Not Present N A 00 18 8B 00 19 B9 00 22 19 00 1E 4F N A N A N A N A N A EFs BES D2 BES 45 FE LUF FC 2A E2 D4 DC 00 18 8B FF 45 26 00 22 19 D2 1E A2 N A N A N A N A N A N A N A N A N A 00 18 8B FF AA 202 00 19 B9 FF FC 0C N A OO 1E 4F FF FO BO N A N A N A N A N A 00 18 3F2 N A OO 1E B4 N A 00 00 00 00 00 00 00 00 00 00 00 100 00 05 0B N A 8B AF 00 00 00 00 1E FE EF 00 00 00 00 08 A9 FO 00 00 00 00 EB N A 00 18 8B FF AA 04 00 19 B9 FF FC 0E N A OO 1E 4F FF F0 B2 N
199. ser names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None cfgADGlobalCatalog2 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the Global Catalog server for user names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None cfgADGlobalCatalog3 Read Write F NOTE This object is applicable only to iDRAC6 Description iDRAC6 uses the value specified to search the Global Catalog server for user names Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name FODN Default None 214 iDRAC6 and CMC Property Database Group and Object Descriptions cfgADCertValidationEnable Read Write F NOTE This object is applicable only to iDRAC6 Description Enables or disables Active Directory certificate validation as a part of the Active Directory configuration process Legal Values 1 TRUE 0 FALSE Default l cfgADDcSRVLookupEnable Read Write F NOTE This object is applicable only to iDRAC6 Description Configures iDRAC6 to use pre configured domain controllers or to use DNS to find the domain controller If using pre configured domain controllers then the domain controllers to use are specified under cfgAdDomainContr
200. settings including stateless Pv6 address es and gateway Legal Values 0 static addressing is used 1 address is obtained from the DHCPv6 server and or stateless auto configuration Default None cfgCurrentLinkLocalAddress Displays the current IPv6 link local address of the CMC cfgCurrentlPv6Address1 Displays the current IPv6 addresses This property displays up to 15 global IPv6 addresses including stateful and stateless addresses cfgCurrentlIPv6Gateway Displays the current Pv6 gateway cfgCurrentIPv6DNSServersFromDHCP6 Indicates whether the DNS server addresses are assigned from the DHCPv6 server cfgCurrentIPv6DNSServer1 Displays the IPv6 address for DNS server 1 cfgCurrentIPv6DNSServer2 Displays the IPv6 address for DNS server 2 Example racadm getconfig g cfgCurrentIPv6LanNetworking cfgCurrentIPv6Enabled 1 cfgCurrentIPv6 AutoConfigWasUsed 1 cfgCurrentLinkLocalAddress fe80 2le 4fff felf 5371 64 cfgCurrentIPv6Address1l 266 iDRAC6 and CMC Property Database Group and Object Descriptions 2009 123 e48f 9dd8 6f51 a669 64 cfgCurrent IPv6 Address2 d88 1 21le 4fff felf 5371 64 cfgCurrentIPv Address3 d88 2 21e 4fff felf 5371 64 cfgCurrent IPv6 Gateway fe80 21c 23ff fe77 6215 cfgCurrent IPv6 DNSServersFromDHCP 6 1 cfgCurrent IPv6 DNSServer1l 2009 123 1 cfgCurrentIPv6 DNSServer2 cfgIPv6URL This group specifies properties used to configure iDRAC6 IPv6 URL
201. subcommand you must have Chassis Control Administrator privilege Subcommand Description chassisaction Executes a power action on the chassis iKVM or a server Synopsis racadm chassisaction m lt module gt lt action gt Table 2 1 describes the chassasaction subcommand options Table 2 1 chassisaction Subcommand Options Option Description m Module on which you want to carry out the action Values are module chassis this is the default value if m is not specified switch n where n 1 6 kvm lt action gt Action that you want to execute on the specified module Values are powerdown Chassis only Powers down the chassis powerup Chassis only Powers up the chassis e powercycle Power cycles the module e nongraceshutdown Chassis only Shuts down the chassis non gracefully reset Performs a hard reset of the module NOTE When lt module gt kvm or switch lt action gt must be powercycle or reset Example Perform a reset of switch 3 racadm chassisaction m switch 3 reset Module power operation successful 38 RACADM Subcommand Details clearasrscreen F NOTE To use this subcommand you must have Clear Logs permission Subcommand Description clearasrscreen Clears the last crash ASR screen that is in memory See Configuring the Managed Server to Capture the Last Crash Screen and Disabling the Windows Automatic R
202. tOnce Write Only 208 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerConsumption 0 racadm getconfig g cfgServerInfo i 1 cfgServerInfoIndex 1 cfgServerSlotNumber 1 cfgServerServiceTag 1S0M0G1 cfgServerName SLOT O1 cfgServerFW 1 40 Build 12 t cfigServerBIOS 4 0 2 cfgServerBmcMacAddress 00 18 8B FF 41 43 cfgServerNiclMacAddress 00 1A A0 FF D9 F4 cfgServerNic2MacAddress 00 1A A0 FF D9 F6 cfgServerPriority 1 cfgServerNicEnable 1 cfgServerIPMIOverLANEnable 1 cfgServerPowerBudgetAllocation 0 cfgServerDNSRegisterIMC 0 cfgServerDNSIMCName iDRAC 1S0M0G1 cfgServerRootPassword Write Only cfgServerFirstBootDevice Write Only cfgServerBootOnce Write Only cfgServerPowerConsumption 0 cfgActiveDirectory This group contains parameters to configure iDRAC6 or CMC Active Directory feature F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can configure any setting that is not preceded by the hash sign in the output To modify a configurable object use the o option iDRAC6 and CMC Property Database Group and Object Descriptions 209 The following sections provides information about the objects in the cfgActiveDirectory group cfgADRacDomain R
203. the time zone by name or index or lists possible time zones lt zone gt may be e lt gt lists the major timezone names prefixes e lt timezone gt is the case sensitive name of your timezone or the index listed by z timezone prefix lt timezone prefix gt is a prefix of one or more timezones followed by E NOTE The timezone daylight savings time is fully supported for l and z options Omit the l option to set the timezone only eg z US Central l Sets the local date and time in the string yyyymmddhhmms s where e yyyy isa the year mmis the month ddis the day hhis the hour mmis the minute ss is the second NOTE Setting the time using the I and z options is recommended This command format allows the CMC to fully support local time zones including the ability to automatically adjust the CMC time to the local Daylight Savings Time Example The setractime subcommand supports dates ranging from 1 1 1970 00 00 00 through 12 31 2030 23 59 59 To set the date to October 24 2007 at 3 02 30 PM PST racadm s The tim etractime 1 20071024150230 z PST8PDT was set successfully RACADM Subcommand Details 123 setslotname F NOTE To use this subcommand you must have Administrator privilege F NOTE See the Editing Slot Names section in the Dell Chassis Management Controller User Guide for rules for selecting slot names Subcommand Description setslotname Displays the
204. tion that is attached as a bootable device For more information see cfgVFlashPartitionOSVolLabel ReadOnly on page 278 No Override PXE HDD DIAG CD DVD BIOS vFDD VCD DVD iSCSI VFLASH FDD SD No Override cfgServerBootOnce Read Write F NOTE For CMC this object is Write only Description Legal Values Default Enables or disables the server boot once feature 1 TRUE 0 FALSE 1 iDRAC6 and CMC Property Database Group and Object Descriptions cfgServerPowerConsumption Read only F NOTE This object is applicable only to CMC Description Displays the current power consumption for a server Legal Values None Default None Example racadm getconfig g cfgServerlnfo i 8 cfgServerlnfolndex 8 cfgServerSlotNumber 8 cfgServerServiceTag cfgServerName SLOT 08 cfgServerFW 3 0 cfgServerBIOS 7 cfgServerBmcMacAddress 00 21 9B FE 5F 58 cfgServerNiclMacAddress 00 0D 56 B8 69 63 170 CMC Property Database Group and Object Definitions cfgServerNic2MacAddress 00 0D 56 B8 69 65 cfgServerNic3MacAddress 00 0D 56 B8 69 CB cfgServerNic4MacAddress 00 0D 56 B8 69 CD Q fgServerPriority 1 cfgServerNicEnable 1 Q fgServerIPMIOverLANEnable 1 cfgServerPowerBudgetAllocation 0 cfgServerDNSRegisterIMC 0 cfgServerDNS IMCName iDRAC cfgServerRootPassword Write Only cfgServerFirstBootDevice Write Only cfgServerBoo
205. to the iDRAC firmware if CMC firmware version is 2 0 or later and iDRAC firmware version is 1 4 when the existing firmware is corrupted There can only be a single update operation in progress at any time In addition the fwupdate subcommand may only update one or more devices of a single kind at a time Before you begin your firmware update see the Advanced iDRAC6 Configuration section in the iDRAC6 User s Guide available on the Dell Support website at dell com support manuals F NOTE Running the fwupdate subcommand to update the firmware on the active CMC resets itself causing all network connections to be dropped During update of all other modules including the standby CMC the active CMC continues to run normally without resetting 54 RACADM Subcommand Details Table 2 10 describes the firmware update method supported for each interface Table 2 10 Firmware Update Matrix FW Update Method Monolithic Modular CMC Local RACADM 2 s Local RACADM TFTP 2 A Remote RACADM q s s Remote RACADM TFTP lt amp 2 s s Remote RACADM FTP Firmware RACADM TFTP amp 2 s Firmware RACADM FTP 9 s Synopsis for iDRAC6 racadm fwupdate s racadm fwupdate g u a lt TFTP Server IP Address gt d lt path gt racadm fwupdate r racadm fwupdate p u d lt path gt Synopsis for CMC For local RACADM racadm fwupdate g u a lt tftp server ip address or FQDN gt d
206. tween host server LOM2 LOM 2 integrated network interface controllers Dedicated Specifies that the RAC NIC is used as the dedicated NIC for remote accessibility iDRAC6 and CMC Property Database Group and Object Descriptions 157 Table 3 2 cfgNicSelection Supported Modes continued Mode Description Shared with Failover All Enables teaming capabilities between all LOMS on the LOMs host server integrated network interface controllers The remote access device network interface is fully functional when the host operating system is configured for NIC teaming The remote access device receives data through NIC and NIC 2 but transmits data only through NIC 1 Failover occurs from NIC 2 to NIC 3 and then to NIC 4 If NIC 4 fails the remote access device fails over all data transmission back to NIC 1 but only if the original NIC 1 failure has been corrected cfgNicVLanEnable Read Write F NOTE For iDRAC6 Enterprise on Blade Servers this object is read only and VLAN settings can be configured through CMC Web Interface iDRACE6 displays only the current VLAN settings and you cannot modify the settings from iDRAC6 Description Enables or disables the VLAN capabilities of the RAC BMC NOTE For iDRAC6 Enterprise on Blade Servers this object enables or disables the VLAN capabilities of iDRAC6 from CMC All chassis management traffic including the CMC and all iDRACs resides on this external VLAN when enabled No iD
207. ty Database Group and Object Descriptions cfgRemoteHosts This group provides properties that allow configuration of the SMTP server for e mail alerts For CMC this group enables disables and configures firmware updates NTP remote syslogging and SMTP email alerting Use the m option to apply this setting to iDRAC F NOTE Use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege The following sections provides information about the objects in the cfgRemoteHosts group cfgRhostsFwUpdateTftpEnable Read Write Description Enables or disables iDRAC6 or CMC firmware update from a network TFTP server Legal Values 1 TRUE 0 FALSE Default l cfgRhostsFwUpdatelpAddr Read Write Description Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP iDRAC6 or CMC firmware update operations Legal Values A string representing a valid IPv4 or IPv6 address For example 192 168 0 61 Default For Pv4 it is 0 0 0 0 iDRAC6 and CMC Property Database Group and Object Descriptions 165 cfgRhostsFwUpdatePath Read Write Description Specifies TFTP path where iDRAC6 or CMC firmware image file exists on the TFTP server The TFTP path is relative to the TFTP root path on the TFTP server NOTE The server may still require you to specify the drive for example C Legal Values A string with a maxim
208. ubcommand you must have Configure iDRAC permission Subcommand Description sslcertupload Uploads a custom SSL server or CA certificate for Directory Service from the client to IDRAC6 Synopsis racadm sslcertupload t lt type gt f lt filename gt RACADM Subcommand Details 129 Table 2 40 describes the sslcertupload subcommand options Table 2 40 sslcertupload Subcommand Options Option Description t Specifies the type of certificate to upload either the CA certificate for Directory Service or the server certificate 1 server certificate 2 CA certificate for Directory Service 3 KMS public certificate 4 KMC public certificate NOTE The current release does not support type 3 and 4 f Specifies the file name of the certificate to be uploaded If the file is not specified the sslcert file in the current directory is selected e Allows for upload of multiple certificate format types 1 Base64 2 PKCS12 NOTE The current release does not support this option p Pin for decrypting the PKCS12 file uploaded NOTE If lt format type is selected as 2 it is mandatory to specify p option NOTE The current release does not support this option The sslcertupload command returns 0 when successful and returns a nonzero number when unsuccessful Example racadm sslcertupload t 1 f c cert cert txt 130 RACADM Subcommand Details sslcertview F NOTE To use this sub
209. ucture Device Firmware section of the Using the CMC Web Interface chapter of the Dell Chassis Management Controller User Guide for additional information on the IOM infrastructure device firmware update process When you use the server generation option the CMC updates all iDRACs of that particular generation that can be updated NOTE Verify that the update applied to servers for a particular generation has been validated for all impacted server models Examples for CMC Upload the firmware image from the TFTP server and start the firmware update racadm fwupdate g u a 192 168 0 100 qa firmimg cmc m cme activ TFTP firmware update has been initiated This update process may take several minutes to complete 58 RACADM Subcommand Details Upload the firmware image from the FTP server and start the firmware update racadm fwupdate f 192 168 0 100 fred password123 d firmimg cmc m cmc activ Start IOM infrastructure firmware update racadm fwupdate u m iominf 1 Update firmware on both the CMCs racadm fwupdate g u a 192 168 0 100 dq firmimg cmc m cmc activ m cmc standby Update firmware on multiple servers racadm fwupdate g u a 192 168 0 100 d firmimg imc m server 1 m server 2 m server 3 Update firmware on servers of iDRAC6 generation racadm fwupdate g u a 192 168 0 100 qd firmimg imc m server idrac6 Update firmware on multiple IOM infrastructures racadm fwupd
210. ult for iDRAC The current iDRAC6 firmware build version Default for CMC The current CMC firmware build version idRacName Read Only Description A user assigned name to identify this controller Legal Values A string of up to 15 ASCII characters DefaultforiDRAC iDRAC Default for CMC CMC idRacType Read Only Description Identifies the remote access controller type as iDRAC6 Legal Values Product ID Default For iDRAC6 on Rack and Servers 10 For iDRAC6 Enterprise on Blade Servers 8 iDRAC6 and CMC Property Database Group and Object Descriptions 155 Example racadm getconfig g idRacInfo idRacType 8 idRacProductInfo Chassis Management Controller idRacDescriptionInfo This system component provides a complete set of remote management functions for blade servers idRacVersionInfo P21 idRacBuildInfo 200708301525 idRacName CMC 1 cfgLanNetworking This group contains parameters to configure iDRAC6 or CMC NIC One instance of the group is allowed Some objects in this group may require iDRAC6 NIC to be reset which may cause a brief loss in connectivity Objects that change iDRAC6 NIC IP address settings closes all active user sessions and require users to reconnect using the updated IP address settings F NOTE For CMC use this object with the config or getconfig subcommands F NOTE To use this object property for CMC you must have Chassis Configuration Administrator privilege F NOTE For CMC you can
211. um length of 255 ASCII characters Default lt blank gt cfgRhostsSmtpServerlpAddr Read Write Description The IPv4 or IPv6 address of the network SMTP server The SMTP server transmits e mail alerts from i DRAC6 or CMC if the alerts are configured and enabled Legal Values A string representing a valid SMTP server IPv4 or IPv6 address For example 192 168 0 55 Default For iDRACE For IPv4 it is 0 0 0 0 For CMC localhost localdomain cfgRhostsNtpEnable F NOTE This object is applicable only for CMC Description Enables or disables the use of the Network Time Protocol NTP for date and time synchronization Legal Values true 0 false Default 0 166 iDRAC6 and CMC Property Database Group and Object Descriptions cfgRhostsNtpServer1 F NOTE This object is applicable to CMC only Description Legal Values Default Specifies the first of three possible NTP servers A string representing a valid NTP server For example ntp1 ntp net At least one NTP server must be specified and duplicate entries are not allowed Null cfgRhostsNtpServer2 F NOTE This object is applicable only for CMC Description Legal Values Default Specifies the second of three possible NTP servers A string representing a valid NTP server For example ntp2 ntp net At least one NTP server must be specified and duplicate entries are not allowed Null cfgRhostsNtpServer3 F NOTE This object is applicable only fo
212. upload f lt filename gt lt filename gt is the name of the file including the path Table 2 27 describes the krbkeytabupload subcommand options Table 2 27 kerbkeytabupload Subcommand Options Option Description f Specifies the file name of the keytab to be uploaded If the file is not specified the keytab file in the current directory is selected The krbkeytabupload command returns 0 when successful and returns a non zero number when unsuccessful Example racadm krbkeytabupload f c keytab krbkeytab tab RACADM Subcommand Details 105 kmcSelfSignedCertGen F NOTE The current release does not support this subcommand F NOTE This is a non extensible command that does not take any specific options Subcommand Description kmcSelfSignedCertGen Generates the new self signed certificate for KMS purposes To generate a selfsigned certificate data such as certificate specific information like Common name Organization Unit key size and so on are required This information is taken from the cfgRacSecurityData group with index set to 2 localConRedirDisable F NOTE Only a local RACADM user can execute this command F NOTE This option is applicable only for iDRAC6 Subcommand Description localConRedirDisable Disables Virtual Console to the management station Synopsis racadm localConRedirDisable lt option gt If lt option gt is set to 1 Virtual Console is disabled If
213. ve 52 RACADM Subcommand Details Synopsis racadm featurecard s Table 2 8 describes the featurecard subcommand option Table 2 8 featurecard Subcommand Options Option Description s Lists active SD card features and SD card status Example racadm featurecard s he feature card inserted is valid serial number EST0123456789012345678 3 The feature card contains the following feature s FlexAddress The feature is bound to this chassis FlexAddressPlus The feature is bound to this chassis ExtendedStorage The feature is bound to this chassis RACADM Subcommand Details 53 fwupdate F NOTE To use this subcommand for CMC you must have Chassis Configuration Administrator privilege and for iDRAC you must have Configure iDRAC6 permission Subcommand Description fwupdate Allows you to update the firmware on the iKVM active CMC standby CMC server iDRACs or an IOM infrastructure device You can e Check the firmware update process status e Update iDRAC6 or CMC firmware from a TFTP server by providing an IP address and optional path e Update iDRAC6 or CMC firmware from the local file system using local RACADM Rollback to the standby firmware Table 2 9 describes the fwupdate subcommand options Table 2 9 fwupdate Subcommand Options Option Description S Lists active SD card features and SD card status F NOTE This subcommand performs updates
214. wer in watts available for use by the chassis cfgChassisStandbylnPowerCapacity Read Only Indicates the amount of power in watts available for powering up any hardware modules that are either added to the chassis or powered up if they are already present in the chassis cfgChassisPowerClear Write Only To reset cfgChassisMinPower and cfgChassisMaxPowerCapacity set this object to 1 cfgChassisPowerClearTimestamp Read Only Time stamp when cfgChassisMin Power and cfgChassisMaxPowerCapacity were reset 230 iDRAC6 and CMC Property Database Group and Object Descriptions cfgChassisPowerButtonEnable Read Write Description Indicates if the chassis power button is enabled or disabled Legal Values 0 disabled 1 enabled Default None cfgSystemEnergyConsumptionClear Write Only To reset energy statistics set this value to 1 Examples racadm getconfig g cfgChassisPower cfgChassisInPower 0 W 0 BTU hr cfgChassisPeakPower 0 W cfgChassisPeakPowerTimestamp 06 32 55 01 26 2009 cfgChassisMinPower 0 W cfgChassisMinPowerTimestamp 06 32 55 01 26 2009 cfgChassisPowerStatus 5 cfgChassisRedundantState 0 fgChassisPowerCap 16685 W fFgChassisPowerCapF 16685 W fgChassisPowerCapBTU 56931 BTU hr fgChassisPowerCapFBTU 56931 BTU hr fgChassisPowerCapPercent 100 fFgChassisPowerCapFPercent 100 fFgChassisRedundancyPolicy 0 FgChassisDynamicPSUEngagementEnable 0 cfgChassisInMaxPowerCapacity 0 W cfgChassisInRedundancyReserve
215. y be used as a last case resort of resetting iDRAC6 controller for recovery purposes soft A soft reset performs a graceful reboot operation on the RAC Examples racadm racreset Start the iDRAC6 soft reset sequence 112 RACADM Subcommand Details e racadm racreset hard Start the iDRAC6 hard reset sequence racresetcfg F NOTE To use this subcommand you must have Configure iDRAC permission Subcommand Description racresetcfg Removes all user configured database property entries The database has default properties for all entries that are used to restore IDRAC6 to the default settings After resetting the database properties IDRAC6 resets automatically F NOTE The racresetcfg subcommand does not reset the cfgDNSRacName object F NOTE This command deletes your current iDRAC6 configuration and resets iDRAC6 and serial configuration to the default settings After reset the default name and password is root and calvin respectively and the IP address is 192 168 0 120 Only for iDRAC6 Enterprise on Blade servers it is IP address plus the number of the slot the server inhabits in the chassis If you issue racresetcfg from a network client for example a supported Web browser Telnet ssh or remote RACADM you must use the default IP address F NOTE Certain iDRAC6 firmware processes need to be stopped and restarted for resetto defaults to complete iDRAC6 becomes unresponsive for about 30 seconds
216. zo0sbR6Jd gA5YNbWs3ekoxXV fe3yJIVpVc 5zrrr7XrwKbJAJTQSw8Dg3iR4n3vUaP 1PHmUv5Mn55 Ea6LHUslAXFqXmOd1Thd wilU2VLw iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4i sCNJU 1024 bit RSA converted from OpenSSH by XX_XX XX XX Key ID 2 Key ID 3 Key ID 4 sslcertdownload F NOTE To use this subcommand you must have Configure iDRAC permission Subcommand Description sslcertdownload Downloads an SSL certificate from iDRAC6 to the client s file system Synopsis racadm sslcertdownload t lt type gt f lt filename gt Table 2 39 describes the sslcertdownload subcommand options Table 2 39 sslcertdownload Subcommand Options Option Description t Specifies the type of certificate to download either the CA certificate for Directory Service or the server certificate server certificate 2 CA certificate for Directory Service 3 KMS public certificate 4 KMC public certificate NOTE The current release does not support type 3 and 4 128 RACADM Subcommand Details Table 2 39 sslcertdownload Subcommand Options f Specifies the file name of the certificate to be uploaded If the f option or the filename is not specified the sslcert file in the current directory is selected The sslcertdownload command returns 0 when successful and returns a nonzero number when unsuccessful Example racadm sslcertdownload t 1 f c cert cert txt sslcertupload F NOTE To use this s

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger - Reha  BIAevaluation (Ver.3、4共通)  Philips 5000 series BDP5600    Bedienungsanleitung  File:Solar Lanterns Test  LP10A Logic Probe User Manual.  Biostar P4TSG Pro Owner's Manual  Wordpress - Manuel utilisateur  Rexel Joy  

Copyright © All rights reserved.
Failed to retrieve file