1. The fan will run at a fixed speed at this setting Keep windows and doors closed for the best dehumidifying effect Do not put the duct to window 4 HEATING OPERATION Cooling only type without heat feature Operating temperature range 5 C 30 C 41 F 86 F Press the MODE button several times until the HEAT indicator light comes on Press the TEMP SETTING buttons A W to select your desired room temperature 17 C 30 C 63 F 86 F Press the FAN SPEED button to choose the fan speed Do not put the duct to window 5 FAN OPERATION Press the MODE button several times until the FAN indicator light comes on Press the FAN SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time you need the unit start to operate The Operation Paned Window will display ON The starting time is adjustable from 0 00 to 24 Setting the off timer Press the TIMER OFF button when the air conditioner is on Select the time you need the unit turn off The Operation Panel Window will display OFF The turning off time is adjustable from 0 00 to 24 7 WATER PUMP DRAINAGE Connect the water pump drain hose to the unit before operate When the water level of the internal water tank reaches a predetermined level the water pump will be activated and drain the condensed water outside thr
2. DAEWOO ROOM AIR CONDITIONER USE amp CARE MANUAL PORTABLE TYPE ROOM AIR CONDITIONER moveL DOC 091R DOC 091RH U UL and C US CUL listed LISTED Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems cons ult your dealer for help or DAEWOO ELECTRONICS Please keep this manual well CONTENTS RULES ee greece cen Ei Z NAMES OF PARTS eons eres uae teen nce E e Ei SACCESSORIES paa a ai 4 0PERATION PANEL OF THE AIR 5 INSTRUCTION FOR THE AIR CONDITIONER 6 TROUBLE SHOOTING SAFETY RULES DO NOT CONNECT UNIT TO ANY AC SOCKET IN DISREPAIR OR WITH CONNECTIONS DO NOT USE IN THE FOLLOWING LOCATIONS NEXT TO SOURCE OF FIRE AN AREA WHERE OIL IS LIKELY TO SPLASH AREA EXPOSED TO DIRECT SUNLIGHT AREA WHERE WATER IS LIKELY TO SPLASH NEAR A BATH A SHOWER OR A SWIMMING POOL IN THE GREEN HOUSE NEVER INSERT YOUR FINGERS OR ANY FOREIGN OBJECTS INTO THE AIR OUTLET TAKE SPECIAL CARE TO WARNCHILDREN OF THESE DANGERS ALWAYS STORE THE UNIT UPRIGHT IN ORDER TO MAINTAIN THE COMPRE SSOR IN A PROPER CONDITION BE SURE TO UNPLUG THE UNIT BEFOR
3. The warranty service center list is constantly changing with the addition of our current qualified service centers If there is inadequate or no local service facility subject individual customer will call DAEWOO on the toll free number 1 800 DAEWOO8 1 800 323 9668 to be provided with further informations
4. desired room temperature setting by pressing the button A up or button VY down AN OS oK O og ee INFRARED OG d 4 POWER INDICATOR SIGNAL RECEIVER 0G a POWER BUTTON Turn on off the unit gt gt EC TIMER ON OFF INDICATOR MODES BUTTON Select the operation mode from COOL DRY FAN HEAT FAN SPEED BUTTON TIMER ON OFF BUTTON Select the fan speed from Program the on off timer function HIGH MED or LOW OPERATING PANEL Fig 3 OPERATION PANEL OF THE CONDITIONER COOLING ONLY TYPE COOL DRY FAN INDICATOR DIGITAL DISPLAY FAN SPEED INDICATOR Green lamp will light when the mode is selected WATER FULL INDICATOR Red lamp will blink when the tank is full TEMP SETTING BUTTON Select your desired room temperature setting by pressing the button A up or button down OS o og pee INFRARED d x POWER INDICATOR SIGNAL RECEIVER 0G POWER BUTTON Turn on off the unit lt i TIMER ON OFF INDICATOR MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW TIMER ON OFFBUTTON Program the on off timer function OPERATING PANEL Fig 4 OPERATING INSTRUCTING FOR THE AlR CONDITIONER Before Starting This Unit 1 Select a suitable location make sure you have easy access to an electrical outlet 2 Install the Fl
5. E CLEANING THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A SOCKET OUTLET THE APPLIANCE IS COVERED THERE IS RISK OF OVERHEAT THE SUPPLY TOOL OF THIS APPLIANCE IS DAMAGED IT MUST BE REPLACED BY A REPAIR SHOP APPOINTED BY THE MANUFACTURER BECAUSE SPECIAL PURPOSE TOOLS ARE REQUIRED NOTE The air conditioner can be connected only to a supply with system impedance no more than 0 4582 ohm In case necessary please consult your supply authority for system impedance information NAMES OF PARTS OPRATION PANEL AIR INLET INDOOR REAR COVER FRONT COVER ae AIR OUTLET OUTDOOR WATER PUMP DRAIN HOSE AIR INLET COUTDOOR AIR INLET REMOTE CONTROLLER OUTDOOR POWER CORD 7 CONTINUOUS 1 DRAIN HOSE CASTER FRONT VIEW SIDE VIEW REAR VIEW Fig 1 ACCESSORIES C Q B ADAPTOR A FOR PERMANENT DUCT MOUNTING C ADAPTOR B FOR TEMPORARY DUCT MOUNTING 1 1 lt gt 6 FS SCREWS ALKALINE BATTERIES 0 REMOTE CONTROLLER ey WATER PUMP DRAIN HOSE Fig 2 e Check all the accessories are included in the package and please refer to the installation instructions for their usage OPERATION PANEL OF THE CONDITIONER COOLING AND HEATING COOL DRY FAN HEAT INDICATIOR DIGITAL DISPLAY FAN SPEED INDICATOR Green lamp will light when the mode is selected WATER FULL INDICATOR Red lamp will blink when the tank is full TEMP SETTING BUTTON Press your
6. ck drainage hole and drain the water off The unit will continue operating Window Slider Kit 67 5 2 22 properly Maxmum 123cm 4 04ft MAINTENANCE Fig 11a IMPORTANT 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2 DO NOT USE GASOLING THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT 3 DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE THE ELECTRICAL CAUE DANGER 4 IF THE POWER CORD IS DAMAGED IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY 1 FILIER Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust Removal Pull out the filter cover and remove the air filter from the filter cover Cleaning Wash the air filter by immersing it gently in warm water about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Mounting Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover Put the filter cover back to the unit 2 UNIT ENCLOSURE Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finished by a dry clean cloth TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1 UNIT DOES NOT Water full indicator blinks water tank Dump the water in the water tank START WHEN is full PRESSING 1 0 BUTTON Room temperature is higher than Reset the temperature the set temperature Heating mode Room temperature is lower
7. e at our store dealer or our authorized service center a sales receipt or bill of sales is required for proof of purchase This warranty does not extend to any of our electronic products which have been subjected to misuse neglect accident incorrect wiring not our own improper installation unauthorized modification or to use in violation of instructions furnished by us nor units which have been repaired or altered outside of our factory nor to cases where the serial number thereof has been removed defaced or changed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer opening a new unit and finding that it is initially defective This unit may be returned to the factory by the dealer for exchange Under no circumstances will an individual customer be permitted to return defective unit directly to factory Exchange must be directly with the dealer When this unit is returned to dealer a copy of the purchase evidence stating the date of purchase is to be put in the individual box for dealer further control with the factory MODEL PARTS LABOR COMPRESSOR DOC 091R 1 year 1 year 5 years DOC 091RH Note
8. exible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig 5 amp Fig 5a NOTE Step 2 is required only while using the cooling mode 3 Plug the unit into a 115V 60Hz grounded electrical outlet 4 Make sure the water pump drain hose is correctly installed 5 Press the off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations The operating range for cooling operating is 17 C 30 C 63 F 86 F the cooling or dehumidifying operations have been switched off and need switching on again ina short time allow approximately three minutes for the cooling or dehumidifying operations to resume Make sure the water pump drain hose is correctly connected to the unit Power supply Insert the AC Power Plug to a AC socket not connect the air conditioner to a multiple socket outlet which is also being used for other electrical appliance sure the power supply is AC 115V 60Hz 2 COOLING OPERATION Operating temperature range 17 C 32 C 63 F 90 F Press the MODE button several times until the COOL indicator light comes on Press the TEMP SETTING buttons A W to select your desired room temperature 17 C 30 C 63 F 86 F Press the FAN SPEED button to choose the fan speed 3 DEHUMIDIFYING OPERATION Operating temperature range 13 C 32 C 55 F 90 F Press the MODE button several times until the DRY indicator light comes on
9. ough the connected drain hose The maximum delivery lift is 3 5m Under this condition attach the rubber blockage to the back hole to prevent continuous drainage 8 CONTINUOUS DRAINAGE When you plan to leave this unit unused for a long time remove the rubber blockage form the back hole and attach a section of the continuous drain hose to drain hose connector All the water in the water tank would drain outside through the drain hose Under this condition the water pump is not activated INSTALLATION 1 IMPORTANT Install the mobile ir conditioner in a flat and spacious location where the air outlets will not be covered up A minimum clearance of 30cm from a wall or other obstacles should be kept The appliance shall not be used in the laundry The plug shall accessible after appliance is positioned Wiring shall be done according to National rules 2 DUCT MOUNT INSTRUCTIONS mm lt TEMPORARY 1 Attach one end of the duct to exhaust air outlet of the mobile air condition first fit the left side of the duct on the exhaust air panel then the right side duct Push it downwards be sure to fix thoroughly See the figures 2 Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to the arrow direction first fit the left side of the duct on the exha
10. than Reset the temperature the set temperature Cooling mode 2 NOT COOL ENOUGH The windows or doors in the room Make sure all the windows and are not closed doors are closed There are heat sources inside the Remove the heat sources if possible room Exhaust air duct is not connected or Connect the duct and make blocked sure it can function properly Temperature setting is too high Decrease the set temperature Air filter is blocked by dust Clean the air filter 3 POWER SHUT OFF AT The automatic over heat protection Switch on again after the unit has cool down HEATING MODE function When the temperature at the air outlet exceed 70 C 158 F the device will stop 4 NOISY OR VIBRATION The ground is not level or not flat Place the unit on a flat level enough ground if possible 5 GURGLING SOUND The sound comes from the flowing It is normal of the refrigerant inside the air conditioner Limited Warranty DAEWOO DAEWOO ELECTRONICS AMERICA INC warrants the following Portable room air conditioner to be free from defective material and workmanship and agrees to remedy any such defect or to furnish a new part at the Company option in exchange for any part of any unit of its manufacture which under normal installation use and service disclosed such defect provided the unit is delivered by the owner to store or dealer where purchased or Daewoo authorized service center To establish and receive warranty servic
11. ust air panel then the right side duct Push it downwards be sure to fix thoroughly See the figures 2 Install the adaptor A onto the wall by using 4 wall plug and screws be sure to fix thoroughly See the figures 3 Attach the other end of the duct to adaptor A 4 Cover the hole using the adaptor cap when not in use The duct can be compressed or extended between 500mm and 2000mm but it is desirable to keep the duct length to a minimum IMPORTANT DO NOT OVER BEND THE DUCT SEE FIGURE Window kif Installation Your window kit has been designed to fit most standard Horizontal Vertical and horizontal window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 11 amp Fig 11a for minimum and maximum window openings Window Slider Kit Minimum 67 5cm 2 22ft Maxmum 123cm 4 04ft Drain Tank Safety Feature This unit is equipped with a internal water tank two full safe switch mechanisms one is used to control the water pump drainage the other is used to monitor the water level inside the internal water tank When the water level reaches a predetermined level the full safe switch mechanism is activated The digital display shows 1 the water full Hotizontal indicator light illuminates Carefully move the unit outside remove the rubber blockage from ba