Crestron electronic GLS-ODT-C-2000 User's Manual

image

Contents

1. Crestron GLS ODT C 500 1000 2000 DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR Operations amp Installation Guide CRESTRON FCC Compliance Statement This device complies with part 15 and part 18 of the FCC rules Operation is subject to the following two conditions 1 This device must not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the GLS ODT C units additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron website periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column Crestron Electronics Inc 15 Volvo Drive Rockleigh N
2. ESNET P or System CRESNET NP wire only The following Crestron devices may be used to integrate the sensors into a Cresnet system by NOTE The same Crestron power supply MUST be used to following the schematic shown here power both the sensors and the interface device e g DIN IO8 Otherwise there is a risk of damage to the interface device DIN IO8 DIN AP2 AV2 CP2E PAC2 MP2E PRO2 CNXIO16 To incorporate the internal photocell connect the gray wire to the DIN IO8 or other interface device and cap off the blue wire Any Crestron product with Versiports from the sensor OPERATION DIP Switch Settings Field of View Ranges GLS ODT C 500 The descriptions below refer to a system which has been configured to turn the lights SWITCH 20 TOR VIEN TROUBLESHOOTING on when a room or area is occupied and turn them off when the room or area is PAKA OFF i ON The following table provides corrective action for possible trouble situations If further vacated Single Dual Tech Mode Dual Tech Single Tech assistance is required please contact a Crestron customer service representative 0 PIR Ultrasonic Mode PIR Ultrasonic See eee eee eee ee Dua TEGN MORS TAE TF Hie octal MOLE O Ope tei 10r NG SENEOr r assie Manual Mode Auto Adapting Enabled Auto Adapting Disabled oe EEN EET AF e NOTE Operation is ultimately determined by the control system program and that must infrared
3. J 07647 Tel 888 CRESTRON Fax 201 767 7576 www crestron com Operations amp Installation Guide DOC 6769A 2023016 12 08 Specifications subject to change without notice WARNINGS CAUTIONS amp NOTES WARNING To avoid fire shock or death turn off power at circuit breaker or fuse and test that power is off before wiring CAUTION Insufficient power can lead to unpredictable results or damage to the equipment Please use the Crestron Power Calculator to help calculate how much power is needed for the system www crestron com calculators NOTES Observe the following points regarding sensor installation To be installed and or used in accordance with appropriate electrical codes and regulations If you are unsure about any part of these instructions consult a qualified electrician Sensors must be mounted on a vibration free surface All sensors must be mounted at least 6 feet away from air vents Do not mount sensors closer than 10 feet from each other Do not touch the inner surface of the lens Clean outer surface with a damp cloth only NETWORK WIRING When wiring the Cresnet network consider the following e Use Crestron Certified Wire e Use Crestron power supplies for Crestron equipment e Provide sufficient power to the system PREPARING AND CONNECTING WIRES Strip the ends of the wires approximately 1 2 Use care to avoid nicking the conductors Twist together the ends of the wires that share a connecti
4. ay and overlay components are covered for 90 days batteries and incandescent aea ru dha alae Se ae te joate available To use this feature the photocell adjustment blue knob must be adjusted from 1 4 ne iG products purchased directly from CRESTRON or an authorized e two tables below and in the next column and the Minimum and Default Settings iti i i A a the default position Once this adjustment is made the controlled lights will only turn on if CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the illustration define the settings of the adjustment knobs and the DIP switches j Shite Bry Q Major Motion IR the ambient light present is less than the setting dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or improper installation procedures Furthermore this warranty does not cover any product that has had the serial number altered defaced or removed This warranty shall be the sole and exclusive remedy to the original purchaser In no event shall CRESTRON be liable for incidental or consequential damages of any kind property or economic damages inclusive arising from the sale or use of this equipment CRESTRON is not liable for any claim made by a third party or made by the purcha
5. ials and workmanship under normal use for a period of three 3 years from the date of purchase from CRESTRON with the following exceptions disk drives and any other moving or Occupancy Pattern Learning for Ultrasonic Technology NOTE To manually take the timer out of the 6 second Test mode simply toggle the switch B3 from OFF to ON and back to OFF The sensor learns the occupancy patterns of a space during the course of a day for a seven day period At any given time the sensor will look at the collected data and PHOTOCELL AMBIENT LIGHT OVERRIDE ADJUSTMENT adjust its ultrasonic sensitivity The sensor will adjust the sensitivity to make it less likely to turn on during a period of non occupancy and more likely to turn on during a In order to use the ambient light override functionality of the sensor the sensor must be wired to the GLS SIM or other compatible interface using the gray wire instead of the blue period of occupancy This adapting feature is not applicable when the sensor is using PIR functions only wire This feature allows the user to conserve energy by keeping the controlled lights off when not necessary The sensor does this by measuring the amount of ambient light in the 20 rotating mechanical parts pan tilt heads and power supplies are covered for a period of one 1 year installed area and keeping the controlled lights off if there is enough ambient light ee ere cccccccces touchscreen displ
6. ightly and with circuit conductors push firmly into appropriate wire connector Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors Secure each connector with electrical tape 6 Push wire connections through the center hole of the back cover and into the ceiling 7 Secure the sensor body to the back cover by aligning the arrows Lock it by turning the sensor such that the arrows do not line up 8 Rotate the sensor to the desired orientation 9 Restore power at the circuit breaker or fuse INSTALLATION IS COMPLETE Mounting to Drop Ceiling Using Screws Low Voltage Wires Nut 2 places Back Cover open center to Nasher 2 plages route Low Voltage Wires Sensor Back Cover Mounting Screws 2 places Back Cover internal surface shown Keylock Arrow Back Cover shown mounted Sensor Base ane on ceiling with screws Sensor Front Cover OPTION C Back Box or Surface Mount Raceway Installation 1 Select the location for mounting of the sensor and proper masking for your application Refer to Mounting Masking Location Diagram 2 Refer to the suggested mounting option illustrations below Mounting to Octagon Back Box Installed Flush to Drop Ceiling Octagon Back Box 4 x 1 1 2 deep GLS SIM Optional Drop Ceiling 8 32 Screws y 2 places Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation Wire Mold Back C
7. ironmen EE ie A A a 11 5 a Na a Oan ae or ned ae tal conditions and occupancy patterns other interface device en ao ee e Walk through Mode The walk through feature is useful when a room is momen have been miswired eee tarily occupied With this feature the sensor will turn the lights off shortly after the GLS SIM or other interface Check that the Net ID matches person leaves the room 20 device set to incorrect Net the one expected by the control The walk through feature works as follows When a person enters the room the SDEVEN C Major Motion IR ID system or CLS C6 lights will turn on If the person leaves the room before the walk through time out of 8 l l l GLS SIM DIP switch Refer to control system and 2 5 minutes the sensor will turn the lights off If the person stays in the room for ee settings not correct CLS SiNidocumentatio to longer than 2 5 minutes the sensor will proceed to the Occupied mode T a nea re re if cerai DIP switch e LED Operation There are two LED indicators that will flash when motion is o aea required for 15 F detected The LED flash can be disabled using the LED disable switch setting compatibility with this sensor Green flashes indicate motion detection by ultrasonic technology Red flashes 17 3 indicate motion detection by infrared technology Incorrect programming in Check control system logic or control system contact C
8. o Occupancy Pattern Learning For Delayed Off i long Typical setting is 10 minutes Time Set the delayed off time to six seconds for performing a walk test While the sensor is 8 5 l l The adapted settings can be reset using the DIP switch in Test mode the LEDs will flash amber once a second 11 58 poner 4 2 a N 1 ENSURE POWER IS ON Return and Warranty Policies 3 Locate Dip Switch 3 in Bank B B3 B3 will be in the OFF position from the factory sills 3 a ede Anche P PAra E NE SEE The sensor will automatically change the delayed off time in response to the 4 To start Test mode move switch to ON and back to OFF The Test mode has now C Major Motion IR eet ae ba eli da Ei sacar AN a plc ay SPA occupancy and environmental conditions of the space where it is installed The sensor been initiated with a six second time out Refer to the DIP Switch Settings table l C minor Motion Ultrasonic contact an authorized CRESTRON dealer Only authorized CRESTRON dealers may analyzes the motion signal properties and will minimize the delayed off time duration a SIDE VIEW Major Motion Ultrasonic contact the factory and request an RMA Return Merchandise Authorization number when there is frequent motion detection and lengthen the delayed off time duration NOTE If B3 is already in the ON position then Test mode can be entered by just moving it T Enclose a note specifying the nature of the problem name and phone number of contac
9. on and tin the twisted connection Apply solder only to the ends of the twisted wires Avoid tinning too far up the wires or the end becomes brittle DESCRIPTION The Occupancy Sensor is a low voltage infrared and ultrasonic sensor that works with the GLS SIM or other compatible interface to automatically control lighting The exact behavior of the sensor can be configured via software but the sensor is typically used to turn lights on when a room or area is occupied and to shut them off when the room or area is vacated The sensor continually analyzes and adjusts to changing conditions The sensor uses the latest microprocessor based technology which permits it to continually adjust and optimize its performance The combination of ultrasonic doppler shift motion detection which gives maximum sensitivity and infrared motion detection which gives higher false triggering immunity yields a sensor with excellent performance Model Feature Basics Current Operating Suggested Model No Description Consumption Frequency Coverage Mounting Location Mount in corner GLS ODT C 500 1 Way Dual Technology 500 sq ft over doorway Mount in center of room area GLS ODT C 1000 2 Way Dual Technology 1000 sq ft Mount in center GLS ODT C 2000 2 Way Dual Technology 6 N 2000 sq ft INSTALLATION INSTRUCTIONS These instructions include three typical installation options A B and C Choose one that best suits your needs Othe
10. over Y Back Cover Screws 4 places Wire Mold Round Fixture for raceway mount Optional Mounting Screws 4 places use applicable fittings MOUNTING MASKING LOCATION DIAGRAM The supplied masks mount in the sensor front cover The half mask is supplied pre mounted to demonstrate the mounting method The perforated mask has twelve 30 removable segments that allow you to mask particular areas to prevent undesireable triggers from affecteng the sensor operation The following illustrations provide typical application examples Ba D STA DSRS SNS Masking is not required in a corner mounting application The sensor can not see hallway traffic By masking two sections you can block hallway traffic TYPICAL APPLICATION DIAGRAMS Up to Three in O Parallel GLS ODT C 500 1000 2000 Crestron 2 Series Control Cresnet Processor or CLS C6 Crestron 2 Series Control Processor Cresnet GLS ODT C 500 1000 2000 WIRING DIAGRAMS Connecting Sensors to the GLS SIM All wires from sensor to GLS SIM must be 24 AWG minimum Blue Blue Sensor Sensor 3 2 Red optional Red optional To incorporate the internal photocell connect gray wire to GLS SIM and cap off blue wire from sensor Syst Use CRESNET P or ystem CRESNET NP wire only Connecting Sensors to the DIN IO8 or Equivalent Gray cap off Black Sensor 1 To Control Use CR
11. r methods may be possible but they are not described here Parts Supplied Sensor 1 8 32 x 1 2 screw 2 8 32 x 1 1 2 screw 2 8x32 Washer and Nut 2 Threaded Rod 1 and Hex nut 1 Half Mask 1 360 Perforated Mask 1 Plastic Washer 1 Tools Equipment Required not supplied Phillips Screwdriver Electrical Tape Pliers Pencil Diagonal Cutters 1 Select the location for mounting the sensor and proper masking for your application Refer to Mounting Masking Location Diagram 2 Use the supplied threaded rod or other means to make a hole 1 2 to 1 in the ceiling tile just large enough to pass the shaft of the threaded rod through 3 Insert the sensor wires through the flared end of the threaded rod Position the threaded rod to the base of the sensor 4 Insert the flared end of the threaded rod into the opening in the bottom of the sensor and twist to lock into place 5 Push the wires into the hole in the ceiling tile and insert the threaded rod until the sensor is flush with the tile 6 Insert wires through the hole in the included washer then place the washer over the rod and secure in position using the included hex nut 7 Connect low voltage wires from the GLS SIM or other Crestron device as shown in the wiring diagram Twist strands of each lead tightly and with circuit conductors push firmly into appropriate wire connector Screw connectors on clockwise making sure that no bare conductor show
12. restron for i assistance ADAPTIVE FUNCTIONS DIP Switches Field of View Ranges GLS ODT C 1000 S Gants stav ON Constant motion To test reduce red and The sensor continually analyzes the parameters of the motion detection signal and g y green knob by 15 remove adjusts its internal operation to maximize detection of motion while minimizing the Minimum Setting Factory Default Setting TOP VIEW motion source If no effects of noise electrical noise air currents temperature changes etc jaca change move sensor min Infrared sensor can see To test put sensor in timer 15 7 pmo C Se e amp te lights continue to come ON When the lights turn on the sensor initially begins the Walk through mode Once the O aE J i move senc or room is occupied for longer than 2 5 minutes the sensor ends the Walk through mode 30 sec 30 min i ee er aa Check control system logic or and begins the Occupied mode When the sensor is first installed the delayed off time Adjust Knob Rotation Direction Delayed Off Time Selection Black Knob aaa a EAEE EE A for the Occupied mode is based on the time adjustment settings While the sensor is in i gt EANAN use the delayed off time will change based on how the sensor adapts to the room i conditions Whenever the sensor subsequently turns on the value of the delayed off TEST MODE 4 Lights remain ON too Timer setting too high To test check switch settings time will be the adapted value refer t
13. s all previous pee atl ee Roane eee ue ON 7 Return the red and green knobs to their original positions eae ifonmmation ray wire on ambient light override ing j i g 8 Replace the cover Photocell level setting is complete All brand names product names and trademarks are the sole property of their respective owners Range 100 3000 LUX Windows is a registered trademark of Microsoft Corporation Windows95 98 Me XP Vista and WindowsNT 2000 are trademarks of Microsoft Corporation
14. s below the wire connectors Secure each connector with electrical tape 8 Rotate the sensor to the desired orientation Note that the sensor base and backcover are keyed To lock the device in place ensure that the arrows are not aligned 9 Restore power at circuit breaker or fuse INSTALLATION IS COMPLETE Mounting to Drop Ceiling Using Threaded Rod Low Voltage Wires Drop Ceiling 1 thick maximum Threaded Rod NOTE Wires routed through the Threaded Rod OPTION B Drop Ceiling Installation Using Screws NOTE You may use the mounting screws nuts and washers included or screws in combination with commercially available wall anchors 1 Select the location for mounting of the sensor and proper masking for your application Refer to Mounting Masking Location Diagram 2 Make a hole in the ceiling tile large enough to pass the wire connections and wire nuts through approximately 1 diameter 3 Remove the back cover of the sensor Hold the back cover and body of the sensor and rotate until the two arrows line up and pull them apart 4 Install back cover of the ceiling sensor to the wallboard or drop ceiling using the included screws nuts and washers or screws in combination with commercially available wall anchors OPTION B Drop Ceiling Installation Using Screws Oxelal med 5 Connect low voltage wires from the GLS SIM or other Crestron device as shown in the wiring diagram Twist strands of each lead t
15. ser for a third party CRESTRON shall at its option repair or replace any product found defective without charge for parts or labor Repaired or replaced equipment and parts supplied under this warranty shall be Adjustment Knob Settings To set the Photocell level used with the gray wire connection 0 KNOB DEFAULT Thi i ight i i Range setting Pa Sets the ultrasonic range Full CCW min OFF Full CW max Remove the cover from the sensor Range settin Make note of the position of the red and green knobs Rotate the red and green Full CCW a OFF knobs fully CCW and enter the sensor s Test mode as described above _TrrrrerrererrrtrtrtrtTT Td NO Sets the infrared range Full CW max 3 Rotate the blue knob fully CCW CJ incr eich covered only by the unexpired portion of the warranty oO 4 Wait for the lights to turn OFF Umi gr rere ane Except as expressly set forth in this warranty CRESTRON makes no other warranties expressed or Delayed Off Time a ae min oy sec 5 Rotate the red knob fully CW implied nor authorizes any other party to offer any warranty including any implied warranties of A ARN 6 Slowly rotate the blue knob clockwise until the lights turn ON This is the correct merchantability or fitness for a particular purpose Any implied warranties that may be imposed by l Full CCW Lights stay OFF setting law rls to the terms of this limited warranty This warranty statement supersede
16. t when there is weak and infrequent motion detection to the OFF position person RMA number and return address In the case of a false off condition lights turn off when the room is occupied the a ade may be TEM MIE ator aredi Gxenange of Sarica Wih a CRESTRON Return i ne f o f erchandise Authorization RMA number Authorized returns must be shipped freight delayed off time duration will immediately be lengthened to prevent further false turn NOTE The timer will remain in the 6 second Test mode for 15 minutes then automatically TT Ot A TT Ty a prepaid to CRESTRON 6 Volvo Drive Rockleigh N J or its authorized subsidiaries offs exit Test mode and reset to the delayed off time setting as defined by the black timer knob 23 17 i l 17 23 with RMA number clearly marked on the outside of all cartons Shipments arriving freight collect or without an RMA number shall be subject to refusal CRESTRON reserves the right in its sole and absolute discretion to charge a 15 restocking fee plus shipping costs on any products returned with an RMA 3 Return freight charges following repair of items under warranty shall be paid by CRESTRON shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser Field of View Ranges GLS ODT C 2000 CRESTRON Limited Warranty TOP VIEW CRESTRON ELECTRONICS Inc warrants its products to be free from manufacturing defects in mater
17. technology PIR turns lights on in this mode however motion detection by Walk Through Disable Walk Through Enabled Walk Through Disabled Ea be considered when troubleshooting either technology PIR or ultrasonic will keep the lights on If neither technology Bank B 8 5 5 detects motion the lights turn off after the delayed off time na ERON NEE REFREIN k e Single Tech Mode Only one technology is active in this mode The technology is Override to OFF Auto Mode Lights Forced OFF gt TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION selected by the dip switches Motion detection by the selected technology PIR or Test Mode SESO Enter Exit Test Mode z ultrasonic will turn on the lights as well as keep them on When motion is not LEDs Disable LEDs Enabled LEDs Disabled 0 i lt detected the lights will turn off after the delayed off time i x Lights do not turn ON Circuit breaker or fuse has Reset circuit breaker or e Delayed Off Time The sensor is designed to turn the lights off if no motion is This setting is only used if the Single Technology Option Switch A1 is selected 4 tripped replace fuse detected after a specified time This length of time is called the delayed off time and t E rg ere Verify that all connections is set using the timer black Knob on the sensor The adapting patterns will modify Mini d Default Setti a 2 g d GLS SIM aue Gack E e the delayed off time to fit the parameters of each installation based on env

Download Pdf Manuals

image

Related Search

Related Contents

PDC 5070A ML UM FR Jan17R.indd  Philips AquaTouch HS8460 with refill and charge stand NIVEA FOR MEN shaver  Geo Brick LV User Manual  Brodit ProClip 854928    MAB 102B-14  バルブ技報部門別分類総目次  VOTRE IDENTITÉ MERITE D`ÊTRE RECONNUE!  Una linea completa di pannelli comando dedicati per installazione a  Manual MK-30  