Home

Cooper Lighting INVUE IMI-575 User's Manual

image

Contents

1. These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMi 575 AVvU040300
2. INVUE INSTALLATION INSTRUCTIONS IMPORTANT Read carefully before installing fixture Retain for future reference General Upon receipt of fixture thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise Epic Pole Mounted Fixtures Sheet 1 of 4 Safety This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance Proper grounding is required to insure personal safety Carefully observe grounding procedure under installation section All work should be done by a qualified electrician A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing ARM amp FIXTURE INSTALLATION Bishop Arm VA6005 VA6008 VA6054 VA6057 VA6105 VA6108 amp VA6154 VA6157 See Figure 1 1 Secure arm onto pole and orient 2 Tighten the six set screws located near bottom of arm to 150 in lbs to secure arm Loosen the three arm cap set screws and remove arm cap Pull fixture leads through arm to arm cap location Raise fixture to arm aligning locating pin and socket See Figure 2 Insert and tighten 4 fixture screws with Teflon washers provided in polybag to 80 in Ibs Connect fixture leads to service leads Resecure arm cap with
3. arm cap set screws tightened to 50 in lbs Traditional Arm VA6009 VA6021 VA6058 VA6070 VA6109 VA6121 amp VA6158 VA6170 See Figure 3 1 Slip arm onto pole and orient 2 Tighten the six set screws located near bottom of arm to 150 in lbs to secure arm Loosen the three arm cap set screws and remove arm cap Pull fixture leads through arm to arm cap location Raise fixture to arm aligning locating pin and socket See Figure 2 Insert and tighten 4 fixture screws with Teflon washers provided in polybag to 80 in lbs Connect fixture leads to service leads Resecure arm cap with arm cap set screws tightened to 50 in Ibs Bishop Arm Fixture Screws G 5 3 Teflon Washers Arm Cap __ Arm Cap a Set Screws Set aie el Fig 1 Modern Top These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative oo COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMI 575 AVU040300 INV LJ Epic Pole Mounted Fixtures INSTALLATION INSTRUCTIONS Sheet 2 of 4 he 2 18 04 IMI 575 IMPORTANT Read carefully before installing fixture R
4. etain for future reference FIXTURE MAINTENANCE A Relamping Classical Top Horizontally lamped Loosen two door screws Lower door to tethered resting position See Figure 4 Install suitable lamp Consult re lamp label and lamp instructions for details Do not overtighten Raise door and secure with screws Vertically lamped 1 Loosen and remove ring retaining screws globe retaining ring and globe Components are not tethered See Figure 5 Install suitable lamp Consult re lamp label and lamp instructions for details Do not overtighten Reinstall ring retaining screws securing globe retaining ring and globe In the case of type 3 refractive glass globe use a ae the mark on globe bottom for orientation ari bop Set Screws Traditional Arm B Starter and Fuse Replacement Where applicable Horizontally lamped Loosen two door screws cep Lower door to tethered resting position See Figure 4 se Loosen thumbscrew until rectangular washer can be rotated 90 degrees See Figure 6 Rotate reflector faceplate to release from screws using key hole slots Unplug optic quick disconnect Remove two screws on ballast cover followed by ballast cover See Figure 7 For starter replacement remove the plug in starter from receptacle and replace For fuse replacement unscrew fuse holder cap and replace fuse Resecure fuse holder cap Resecure the ballast cover with the two screws Plug optic quick disc
5. gular washer can be rotated 90 degrees See Figure 6 on A Rotate reflector faceplate to release from screws using key i q Ring Retaining Screws hole slots Globe Retaining Fng Unplug optic quick disconnect Remove two screws on ballast cover followed by ballast cover See Figure 7 Unplug service quick disconnect olding the handle loosen the two screws holding the power g Options ack to the fixture housing See Figure 8 3R amp 5R olding the handle rotate the power pack until free and lower gt olding replacement power pack by handle raise onto screw heads and rotate Tighten the two screws while holding power pack in position Plug together the service quick disconnect Resecure the ballast cover with the two screws Reconnect optic quick disconnect and secure reflector by EA keyhole slots and thumbscrew lt o NS RingiRet iniiaiseraws Raise door and secure with screws A Globe Retaining Ring These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMI 575 AVU040300 INV LJ Epic Po
6. le Mounted Fixtures INSTALLATION INSTRUCTIONS Sheet 4 of 4 2 18 04 IMI 575 IMPORTANT Read carefully before installing fixture Retain for future reference A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing Vertically lamped 1 Loosen and remove ring retaining screws globe retaining ring and globe Components are not tethered See Figure 5 Remove two screws on ballast cover followed by ballast Selle cover See Figure 6 Dleconnest Unplug optic quick disconnect Unplug service quick disconnect Loosen the two screws holding the power pack to the fixture housing See Figure 7 Holding the power pack by the handle rotate the power pack until free and lower Holding replacement power pack by handle raise onto screw heads and rotate ighten the two screws while holding power pack in position Plug together the service quick disconnect Plug together the optic quick disconnect Resecure the ballast cover with the two screws Reinstall ring retaining screws securing globe retaining ring and globe In the case of type 3 refractive glass globe use the mark on globe bottom for orientation Service Quick Disconnect Reflector Removal Keyhole Slot Rectangular Washer Thumbscrew Power Pack Removal
7. onnect and secure reflector by keyhole slots and thumbscrew 10 Raise door and secure with screws te Ji Options FG FR SG amp FRS Door Screws COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 imI 575 AVU040300 INV U Epic Pole Mounted Fixtures INSTALLATION INSTRUCTIONS Sheet 3 of 4 TE f 2 18 04 IMI 575 IMPORTANT Read carefully before installing fixture Retain for future reference A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing Vertically lamped 1 Loosen and remove ring retaining screws globe retaining ring and globe Components are not tethered See Figure 5 Remove two screws on ballast cover followed by ballast cover See Figure 7 Unplug optic quick disconnect For starter replacement remove the plug in starter from receptacle and replace For fuse replacement unscrew fuse holder cap and replace fuse Resecure fuse holder cap Plug optic quick disconnect Resecure the ballast cover with the two screws Reinstall ring retaining screws securing globe retaining ring and globe In the case of type 3 refractive glass globe use the mark on globe bottom for orientation Options FG FR SG amp FRS Option MA C Power Pack Replacement Horizontally lamped Loosen two door screws Lower door to tethered resting position See Figure 4 Loosen thumbscrew until rectan

Download Pdf Manuals

image

Related Search

Related Contents

KA-MR100G - info  établissement donnacona établissement de port  JetFlex 3000 Service Manual  AudioBox™ 22VSL  製品資料 - 株式会社光電製作所  1 - タニタ TANITA  Samsung Galaxy Tab S (10.5, 4G) Brugervejledning  SkyLink 91562-01 User's Manual  TURKISH AIRLINES A320 Full Flight Simulator Technical Specification  Trendnet TV- IP110 surveillance camera  