Chauvet CH-324 User's Manual
Contents
1. to obstruct the air vents After use allow time to cool for safety and to ensure lamp life before moving or touching Installation Mounting Although this unit can be used in an upright position it is recommended that for safety purposes your lighting effect be properly mounted using a suitable hanging clamp and safety cable CHAUVET offers a range of items which are ideal for safe mounting Use in a well ventilated area without obstruction to air vents Replacing Lamps 1 Disconnect from main power supply before attempting to replace either lamps or fuse 2 Ensure that the unit is sufficiently cool before removing blown lamps 3 Never touch new lamps with your fingers use a tissue or a cloth In order to replace the lamp disconnect from main power supply first and unscrew the lamp replacement cover which is highlighted on the diagram fig 1 Only use the appropriately rated lamps as use of any other lamp type may cause the unit to be non operational Due to the nature of halogen lamps it is vitally important that you do not touch the new replacement lamp with your fingers as this will reduce lamp life considerably Once again a tissue or cloth can be used for fitting the replacement lamp Finally before using check that the lamp is housed correctly in the lamp holder and that the lamp replacement cover has been screwed back into place If after replacement of the lamp the unit is still not working then please conta
2. Information Please complete for your records Data Purchased Serial No Dealer Stamp Model CH 324 Gobo Splash World wide Headquarters 3000 North 29 Ct Hollywood Florida USA 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 800 762 1084 www ChauvetLighting com At the Rear Sound sensitivity knob y Mounting Bracket eLamp Replacment Cover eLenses Reflectors 3 dichroic prism e Screw Cap Fuseholder Fig 1 Introduction Congratulations on the purchase of your new CHAUVET lighting effect We are confident you will enjoy many trouble free hours with this unit To assist with the care and use of the product we have prepared this short guide Operation Before connecting this unit to the mains power supply for the first time you must first install the lamps See Replacing Lamps for details This lighting effect has been designed to function on a mains power supply of either 120V 60Hz or 230V 50Hz and has been fitted with a suitable power plug for use with your local voltage Check the label and voltage selector switch if fitted on the unit and the power plug for the correct voltage When connected to the mains power supply the unit should illuminate The unit will also begin to run through its pre programmed patterns This lighting effect is sound activated Due to the high operating temperature of halogen lamps it is advisable that the effect be used in well ventilated areas taking care not
3. Troubleshooting e If the unit is not functional check that the main power supply is on and check fuses e If the unit is functional but the lamp does not light the lamp may require replacing e If after trying the above you still have a problem contact CHAUVET Contact Chauvet USA Technical Assistance 1 800 762 1084 954 929 1115 E Mail tech chauvetlighting com Caution Do not obstruct the air vents Do not touch unit or lamps while hot Never put any objects through the air grill on the top of the unit No user serviceable parts inside Please refer to CHAUVET for service Power Connections The unit is supplied with a power plug appropriate to its voltage and destination Should any other connections be required they must be carried out with the following configuration Earth Green Yellow cable Neutral Blue cable Live Brown cable In the USA amp Europe it is required that all plugs are 3 pin type i e with Earth Ground connection In the UK it is required that all mains plugs are fitted with 5A fuses Technical Specifications Value Innovation Performance Gobo Splash CH 324 Users Guide Please read these instructions carefully before use Power 120V 60Hz AC 230V 50Hz AC Fuse 20mm Glass 5A Fast Blow 20mm Glass 3 15A Fast Blow Lamps 1 X 24V 250W Part No ELC3 24V 250W 300 Hrs Dimensions 368 x 368 x 152mm 14 5 x 14 5 x 6 in Weight 8 5 kg 18 7 Ibs User
4. ct CHAUVET for servicing Replacing Fuses If the unit does not function at all when connected to the main power supply i e the mechanism does not Spin then it is highly likely that the fuse has blown Disconnect from main power supply before attempting to replace either lamps or fuse In order to replace the fuse disconnect from the main power supply first and unscrew the fuse holder cover to reveal the fuse The unit has a label attached which indicates the correct fuse rating and you will also find this listed as part of the specifications for the unit later in this guide It is most important that replacement fuses are of the correct rating Failure to use the correct fuse could damage the lighting effect beyond economic repair The fuse should simply be placed inside the holder and the screw cap replaced when this is done connect to the main power supply to check If the unit is still not working then please contact CHAUVET for servicing Cleaning The most important part your lighting effect to keep clean is the lens as it allows the light output to transmit This should be cleaned with a soft damp cloth The body of the unit may also be cleaned in the same way We recommend internal cleaning be carried out by a fully qualified technician Maintenance amp Servicing Work on internal parts should be carried out by a qualified technician Removal of covers other than the front to replace lamp or the fuse holder is considered a br
5. each of warranty and will not be covered under any such agreement unless authorized first by the company
Download Pdf Manuals
Related Search
Related Contents
HQ BAT-LEAD-16 rechargeable battery 1 Ajuda do HP ENVY 110 e-All-in-One D411 series LCDVD157A - BrandsMart USA Dolmar PS-5100 S Chainsaw User Manual Bedienungsanleitung PAMSB10 - Velleman USO E MANUTENZIONE USE AND MAINTENANCE ScanEx IMAGE Processor version 1.0 TERRAIN Module Drehstrommotoren DRS/DRE/DRP / Operating Instructions / 2007-05 Copyright © All rights reserved.