Home
Chamberlain LSIS User's Manual
Contents
1. heard Press and hold both buttons for 5 seconds Each intercom will emit a tone when programmed into network Repeat for any additional intercoms NOTE Do not program new intercoms to each other before adding them to the network or they will form a separate network and the memory will need to be cleared Press and release the Talk button to verify network is complete Troubleshooting Intercom does not function Check batteries in intercom If using an AC Adapter ensure that it is plugged in Ensure intercom is connected to a network See Programming Intercom Ensure that intercoms are on the same channel See Operation amp Features Intercom is not getting expected transmission range Keep antenna vertical Keep intercom away from trees metal objects and electrical wiring Cell phones cordless phones or other radio devices may also limit range Intercom beeps every ten minutes The battery is low in the intercom Replace with AA Alkaline batteries or operate it with AC Adapter not provided A 9 12 volt 500mA AC Adapter may be used center positive polarity on the round plug Need to clear intercom s memory Press and hold Learn button an initial beep will be heard Continue to hold until a second beep is heard about 15 seconds Ensure other intercoms are not activated during this time Intercoms in the network that are on will signal during the clearing process Once memory is clear the inter
2. CHAMBERLAIN Overview The Intercom has up to a 1000 range and allows multiple simultaneous conversations using a 900 Mhz secure digital radio link The intercoms form an exclusive network and respond only to other intercoms in the network Carton Inventory OO Rubber Pads 2 in Model LSIS Intercom 2 in Model LSIS Operation amp Features Channel Lights Talk Button Power Light Monitor Button pete EQN Speaker Channel Select Volume DOWN Button Volume UP Button Dipswitch 1 Dipswitch 2 Learn Button On Off To turn intercom ON press Talk button To turn intercom OFF hold down the Volume DOWN button for 5 seconds Talk Button To talk hold down the Ze Talk button All intercoms in the 1 network that are on the same G A channel will receive the signal Release the Talk button when done a talking and within 10 15 seconds press and hold the Talk button of a different intercom to make a secure channel between the two Once the channel is made the other intercoms in the network cannot hear the conversation Volume Pressing the Volume DOWN button will lower the volume and pressing the Volume UP button will increase the volume Model LSIA amp LSIS Wireless Portable Intercom Extreme Range Channel Select Button Press the Channel Select button to set intercom to one of four secure channels or the paging channel The default channel for the intercom is the paging channel wher
3. all to be answered without pressing the Talk button Once a call is heard on an intercom which has been set to VOX a response can be given by speaking loudly into the intercom There will be a slight delay when VOX is first activated by a voice but will continue to transmit audio until E the speaking stops To put intercom into VOX H place Dipswitch 1 to the UP position 1 2 Assemble Intercom Step 1 Install 4 AA Alkaline batteries not provided Lithium batteries recommended for colder environments Step 2 Adhere rubber pads to bottom Repeat Steps 1 and 2 for any additional intercoms Programming Intercom The intercom must be programmed to at least one other intercom to become a network or it can be programmed into an existing network Create New Network Press the Learn button on the new intercom until a beep is heard Within 10 seconds put the second intercom into Learn Mode refer to the following table INTERCOM LEARN MODE Press the Learn button until a beep is heard Press and hold both buttons for 5 seconds Each intercom will emit a tone when programmed into network Repeat for any additional intercoms Add to an Existing Network Press the Learn button on the new intercom until a beep is heard Within 10 seconds put any networked intercom into Learn Mode refer to table below INTERCOM LEARN MODE Press the Learn button until a beep is
4. com can be programmed to a new network Static and feedback is heard in intercom The intercoms are too close to each other A cordless phone cell phone or other radio devices can also cause static Intercom is sending audio while no buttons are pressed The sending intercom is set to Monitoring Mode or Voice Activation Mode and will activate when sound is heard It can be taken out of Monitoring Mode by pressing the Talk button It can be taken out of Voice Activation Mode by setting Dipswitch 1 to DOWN position See Operation amp Features 114A3576 FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER 1 800 528 9131 www chamberlain DlY com NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 2008 The Chamberlain Group Inc All Rights Reserved
5. e all four channel lights are lit An intercom on a channel can only hear an intercom on the same channel or on the paging channel Battery The AA Alkaline batteries not provided will last up to a year depending on use Lithium batteries recommended for colder environments When batteries are low intercom will emit two beeps every ten minutes An AC Adapter not provided can also be used to power the intercom In this case both the power and channel lights will remain on OPTIONAL Conference Mode Conference Mode allows multiple intercoms to participate in a conversation compared to Normal Mode in which only two intercoms can communicate All intercoms must be set to the same channel or the paging channel to be in Conference Mode To put intercom in H H Conference Mode set Dipswitch 2 to UP is position Monitor Mode Monitor Mode is used to monitor the noise in a specific room Place the intercom in the room that is to be monitored and press the Monitor button until a tone is heard The Active Light will be lit while the intercom is in Monitor Mode Any other networked intercom can listen to that room If a specific channel is selected for Monitor Mode then only other intercoms on that channel or on the paging channel can listen Press the Monitor button again to exit Monitor Mode A tone will be heard indicating Monitor Mode is no longer active Voice Activation Mode VOX Voice Activation Mode VOX allows a c