Home

Chamberlain HD930EV User's Manual

image

Contents

1. PUSH BAR Press the push bar to open or close the door LIGHTS Light Button Press the LIGHT button to turn the garage door opener lights on or off When the lights are turned on they will stay on until the LIGHT button is pressed again or until the garage door opener is activated Once the garage door opener is activated the lights will turn off after the specified period of time the factory setting is 4 1 2 minutes The LIGHT button will not control the lights when the door is in motion The duration of the light timing can be adjusted by accessing the menu using the navigation buttons Motion Sensor The motion sensor will automatically turn on the garage door opener lights when motion is detected The lights will come on for the set period of time then shut off The factory setting is on and set at 4 1 2 minutes Operation Using the Smart Control Panel continued Light Feature The lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken If using the garage door opener light as a work light turn the light on using the light button on the wall control or the light will turn off if you are beyond the range of the sensor LOCK The LOCK feature is designed to prevent activation of the garage door opener from remote controls while still allowing activation from the door control and keyless entry This feature is useful for added peace of mind when the home is empty
2. 3 Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded 4 Reinstall the cover Ground Tab pil amp 27 Installation STEP 16 Aligning the safety reversing sensors The door will not close if the sensors have not been installed and aligned correctly When the light beam is obstructed or misaligned while the door is closing the door will reverse and the garage door opener lights will flash ten times Ifthe door is already open it will not close 1 Check to make sure the LEDs in both sensors are glowing steadily The LEDs in both sensors will glow steadily if they are aligned and wired correctly The sensors can be aligned by loosening the wing nuts aligning the sensors and tightening the wing nuts If the receiving sensor is in direct sunlight switch it with sending sensor so it is on the opposite side of the door invisible light beam cia Amber LED Green LED SENDING SENSOR RECEIVING SENSOR 28 IF THE AMBER LED ON THE SENDING SENSOR IS NOT GLOWING 1 Make sure there is power to the garage door opener 2 Make sure the sensor wire is not shorted broken 3 Make sure the sensor has been wired correctly white wires to white terminal and white black wires to grey terminal I d m Qe cr WHITE GREY IF THE GREEN LED ON THE RECEIVING SEN
3. BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT REPLACEMENT OF CONSUMABLE ITEMS E G BATTERIES IN REMOTE CONTROL TRANSMITTERS AND LIGHT BULBS OR UNITS INSTALLED FOR NON RESIDENTIAL USE THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATING TO THE GARAGE DOOR OR GARAGE DOOR HARDWARE INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS DOOR ROLLERS DOOR ALIGNMENT OR HINGES THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE OR INABILITY TO USE THIS PRODUCT IN NO EVENT SHALL SELLER S LIABILITY FOR BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT Some states do not allow the exclusion or limitation of consequential incidental or special damages so the above limitation or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Repair Parts Rail Assembly Parts Installation Parts Description Part Number Description Part Number Belt 41A5250
4. Laser Parking Assistant Park in the right spot every time A laser beam is activated by your garage door opener and projected on to the dashboard of your vehicle to guide perfect parking CLLP1 CIGBU MyQ Internet Gateway Internet enabled accessory EO which connects to the computer and allows you to monitor and control garage door openers and lighting accessories enabled by MyQ technology 44 System Surge Protector The Garage Door Opener Surge Protector is designed to protect Chamberlain garage door openers against damage from lightning and power surges Easy to install Garage Door and Gate Monitor Monitor open closed status for up to 4 MyQ compatible garage door openers or gate operators and close them from anywhere in the home Installation Upgrade Kit The Installation Upgrade Kit includes all components needed to hang garage door Openers up to 24 61 cm from the ceiling 953EV 940EV Remote Control Works with ALL Chamberlain openers from 1993 present MyQ compatible Includes visor clip Keychain Remote Control Works with ALL Chamberlain openers from 1993 present MyQ compatible With key ring Wireless Keypad For use outside of the home to enable access to the garage using a 4 digit PIN Works with ALL Chamberlain openers from 1993 present MyQ compatible Warranty Contact Information For installation and service information call 1 80
5. i e vacation When the Lock feature is on your remote controls have been disabled and a message will display on the door control Figure 1 TIMER TO CLOSE TTC DO NOT enable TTC if operating a one piece door TTC can be set to automatically close your garage door from the fully open position after a specified period of time 1 5 10 minute intervals or a custom setting up to 99 minutes The screen on the door control can display the status ofthe TTC Once the TTC has been setand the door is open the selected close interval will be displayed on the screen and toggle between the time and TTC message When the TTC is on a message will display on the door control screen Figure 2 To temporarily suspend the TTC feature press and release the HOLD button Press REL button to resume normal TTC operation Figure 3 BATTERY BACKUP If your garage door opener has a battery backup one of two messages will display on the door control if there is a problem with the battery Figures 4 and 5 Figure 1 Figure 2 LOCK MODE DOOR WILL CLOSE TRANSMITTERS WILL IN xx MINUTES NOT OPERATE TTC IS ENABLED PRESS HOLD TO PAUSE MENU HOLD Figure 3 DOOR WILL BE HELD OPEN TTC IS PAUSED PRESS REL TO RELEASE zm Te Figure 4 Reece Figure mmm INSTALL BATTERY SUGGESTED FOR OPERATION DURING SEE MANUAL AC POWER LOSS MENU SMART CONTROL PANEL MENU The features on the door control can be programm
6. 1 4 14 5 8 self threading screws are not intended for use on wood doors Vertical Reinforcement FIGURE 1 FIGURE 2 Vertical Reinforcement Vertical Centerline of Garage Door Vertical Centerline of Garage Door Door Bracket Hardware not provided Self Threading Screw y 1 4 14 5 8 FIGURE 4 Inside Edge of Door or Vertical Reinforcement Board Centerline Hardware of Garage not provided Door UP we Self Threading Screw Vertical Centerline of 1 4 14 5 8 Garage Door Installation STEP 8 Install the door bracket continued OPTION B ONE PIECE DOORS 1 Center the door bracket on the top of the door in line with the header bracket as shown 2 Mark either the left and right or the top and bottom holes Metal Doors e Drill 3 16 pilot holes and fasten the bracket with the self threading screws provided Wood Doors e Drill 5 16 holes and use 5 16 18x2 carriage bolts lock washers and nuts not provided or 5 16 x1 1 2 lag screws not provided depending on your installation needs NOTE The door bracket may be installed on the top edge of the door if required for your installation Refer to the dotted line optional placement drawing 17 Header Wall 2x4 Support Finished Ceiling Optional Placement of Door Bracket Vertical Centerline of Garage Door Metal Door Self Threading Screw 1 4 14 5 8 Wood Door
7. ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment 1 Unplug the garage door opener 2 Open the light lens on the right side panel of the garage door opener Use a Phillips head screwdriver to remove the battery cover on the garage door opener 3 Partially insert the battery into the battery compartment with the terminals facing out 4 Connect red and black wires from the garage door opener to the corresponding terminals on the battery 5 Replace the battery cover 6 Plugin the garage door opener 7 Wait for the green Battery Status LED to start flashing before proceeding to test the battery Status LED 32 Battery Backup Charge the Battery The battery charges when the garage door opener is plugged into a 110Vac electrical outlet that has power and requires 24 hours to fully charge A fully charged battery supplies 12Vdcto the garage door opener for one to two days of normal operation during an electrical power outage After the electrical power has been restored the battery will recharge within 24 hours The battery will last approximately 1 to 2 years with normal usage Instructions for replacement are provided with the battery To obtain maximum battery li
8. LED transmits an invisible light beam to the receiving sensor with a green LED If an obstruction breaks the light beam while the door is closing the door will stop and reverse to the full open position and the garage door opener lights will flash 10 times NOTE For energy efficiency the garage door opener will enter sleep mode when the door is fully closed The sleep mode shuts the garage door opener down until activated The sleep mode is sequenced with the garage door opener light bulb as the light bulb turns off the sensor LEDs will turn off and whenever the garage door opener lights turn on the sensor LEDs will light The garage door opener will not go into the sleep mode until the garage door opener has completed 5 cycles upon power up When installing the safety reversing sensors check the following e Sensors are installed inside the garage one on either side of the door e Sensors are facing each other with the lenses aligned and the receiving sensor lens does not receive direct sunlight e Sensors are no more than 6 inches 15 cm above the floor and the light beam is unobstructed Safety Reversing Sensor Invisible Light Beam 6 15 cm max above floor Protection Area D c R lL 3 FW E IS lt 7 ee Facing the door from inside the garage 22 HARDWARE Carriage Bolt Wing Nut 1 4 20x1 2 Inm 1 4 20 The safety reversing sensors can be attached to the door track
9. door will not move more than an inch 2 5 cm and the garage door opener lights will flash 10 times The garage door opener will not close from a remote control if the LED in either safety reversing sensor is off alerting you to the fact that the sensor is misaligned or obstructed If the garage door opener closes the door when the safety reversing sensor is obstructed and the sensors are no more than 6 inches 15 cm above the floor call for a trained door systems technician 2 Battery Backup STEP 1 Install the Battery STEP 2 Test the Battery 1 Unplug the garage door opener The battery status LED will wither glow solid orange indicating A WARN NG opener is operating on battery power or will flash indicating low battery power NOTE Make sure the garage door opener is unplugged To reduce the risk of FIRE or INJURY to persons 2 Open and close the door using the remote control or door control The garage door opener may e Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance run slower ifthe battery is not fully charged The battery will take 24 hours to fully charge Use ONLY Chamberlain part 41A6357 1 for replacement battery 3 Plugin the garage door opener Verify the battery status LED is flashing green indicating the e DONOT dispose of battery in fire Battery may explode Check with local codes for disposal battery is charging instructions
10. header wall above the door You can fasten the header bracket within 4 feet 1 22 m ofthe left or right of the door center only if a torsion spring or center bearing plate is Highest Track in the way or you can attach it to the ceiling see page 12 when clearance is minimal It may be Point of Highest mounted on the wall upside down if necessary to gain approximately 1 2 1 cm Ifyou need to d Travel Point of install the header bracket on a 2x4 on wall or ceiling use lag screws not provided to securely i Door Travel fasten the 2x4 to structural supports as shown here and on page 12 3 Open your door to the highest point of travel as shown Draw an intersecting horizontal line on the header wall 2 5 cm above the high point One piece door without track One piece door without track e 2 5cm above the high point for sectional door and one piece door with track jamb hardware pivot hardware e 8 20 above the high point for one piece door without track Header Wall REC Header 2 This height will provide travel clearance for the top edge of the door NOTE Ifthe total number of inches BILE 20 cm NET exceeds the height available in your garage use the maximum height possible or refer to page 12 for 22 Highest No ceiling installation Point of j Travel f Travel Hardware Pivot 11 Installation STEP 2 Install the header bracket OPTION B CEILING INSTALLATION You can attach
11. reference Model Number Serial Number www chamberlain com The Chamberlain Group Inc Date of Purchase 845 Larch Avenue 7 7 Elmhurst Illinois 60126 1196 Preparation Safety Symbol and Signal Word Review Check the Door This garage door opener has been designed and tested to offer safe service provided itis installed operated maintained and tested in strict accordance with the instructions and warnings contained in this A WARN N G manual To prevent possible SERIOUS INJURY or DEATH When you see these Safety Symbols and Signal Words on the following pages they will alert you to the d HER possibility of serious injury or deathif you do not comply with the warnings that accompany them The ALWAYS call trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may NOT reverse when required hazard may come from something mechanical or from electric shock Read the warnings carefully NEVER try to oen noe ot door MO NI cables pulleys brackets or their hardware ALL of which are under EXTREME tension A WARNING Disable ALL locks and remove ALL ropes connected to garage door BEFORE installation and operating garage door opener to avoid entanglement Mechanical A WARNING Electrical When you see this Signal Word on the following pages it will alert you to the possibility of damage to To pre
12. sensor wires Not Provided Safety reversing Pre installed wires sensor wires White White Black Yellow for example Purple for example Purple for example Yellow for example To insert or remove the wires from the terminal push in the tab with a screwdriver tip Installation STEP 15 Connect power A WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution or fire Be sure power is NOT connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes NEVER use an extension cord 2 wire adapter or change plug ANY way to make it fit outlet Be sure the opener is grounded To avoid installation difficulties do not run the opener at this time To reduce the risk of electric shock your garage door opener has a grounding type plug with a third grounding pin This plug will only fit into a grounding type outlet If the plug doesn t fit into the outlet you have contact a qualified electrician to install the proper outlet THERE ARE TWO OPTIONS FOR CONNECTING POWER OPTION A TYPICAL WIRING 1 Plugin the garage door opener into a grounded outlet 2 DO NOT run garage door opener at this time OPTION B PERMANENT WIRING Models manufactured before October 2012 If permanent wiring is required by your local code refer to
13. the following procedure To make a permanent connection through the 7 8 inch hole in the top of the motor unit according to local code 1 Be sure power is NOT connected to the opener and disconnect power to circuit 2 Remove the garage door opener cover and set aside 3 Remove the attached green ground terminal 4 Cutblack and white wires and strip away 1 2 inch 1 cm of insulation inch 7 5 cm before spade terminals 5 Remove the power cord from opener 6 Install a conduit or flex cable adapter to the 7 8 inch hole 7 Run wires through conduit cut to proper length and strip insulation 8 Attach with wire nuts provided Attach the ground wire to the green ground screw The opener must be grounded 9 Properly secure wire under plastic ties so that wire does not come in contact with moving parts 10 Reinstall the cover DO NOT run garage door opener at this time PERMANENT WIRING Ground Wire Black Wire Ground Tab Green Ground Screw White Wire Wire Nuts Refer to page 27 for models manufactured after October 2012 26 Installation OPTION B PERMANENT WIRING Models manufactured after October 2012 If permanent wiring is required by your local code refer to the following procedure To make a permanent connection through the 7 8 inch hole in the top of the motor unit according to local code 1 Remove the motor unit cover screws and set the cover aside 2 Remove the attached 3 prong cord
14. the garage door encounters an obstruction twice or the safety reversing sensors are incorrectly installed The garage door will reverse open and WILL NOT close until the obstructions are clear or the safety reversing sensors are correctly installed When the obstruction has been cleared or the safety reversing sensors have been aligned the door will close when the garage door opener is activated TTC WILL NOT work if the garage door opener is operating by battery power or if the safety reversing sensors are misaligned This feature is NOT intended to be the primary method of closing the door A keyless entry should be installed in the event of an accidental lock out when using this feature REMOTE CONTROLS AND DOOR CONTROLS MyQ Your garage door opener has already been programmed at the factory to operate with your remote control which changes with each use randomly accessing over 100 billion new codes Compatible with MyQ enabled accessories see page 44 NOTE Older Chamberlain remote controls door controls and third party products are not compatible MyQ Accessories MEMORY CAPACITY Remote Controls Up to8 Door Controls Up to 2 MyQ door controls Keyless Entries Up to 1 35 THE PROTECTOR SYSTEM SAFETY REVERSING SENSORS When properly connected and aligned the safety reversing sensors will detect an obstruction in the path of the infrared beam If an obstruction breaks the infrared beam while the door is closing the do
15. the header bracket either to the wall above the garage door or to the ceiling Follow the 1 Extend the vertical centerline onto the ceiling as shown instructions which will work best for your particular requirements Do not install the header bracket over 2 Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure drywall If installing into masonry use concrete anchors not provided arrow is pointing away from the wall The bracket can be mounted flush against the ceiling when clearance is minimal HARDWARE 3 Mark the side holes Drill 3 16 pilot holes and fasten bracket securely to a structural support with the hardware provided semen Header Ceiling Mounting Bracket OPTION A WALL INSTALLATION 1 Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown with the arrow pointing toward the ceiling 2 Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided 6 15 cm Vertical Centerline of Garage Door Vertical Centerline of Garage Door Lag Screw 5 16 9 1 5 8 Door Spring Wall Mount Header Wall 2x4 Structural Support Lag Screw 5 16 9x1 5 8 Garage Door Header Wall Horizontal Line NC Optional Mounting Holes Highest Point of Garage wie Door Travel
16. 0 528 9131 Before calling please have the model number of the garage door opener If you are calling about a Troubleshooting issue it is recommended that you have access to your garage door Opener while calling If you are ordering a repair part please have the following information part number part name and model number Address repair parts orders to The Chamberlain Group Inc 6050 S Country Club Road Tucson AZ 85706 CHAMBERLAIN FIVE YEAR LIMITED WARRANTY LIFETIME MOTOR AND BELT LIMITED WARRANTY ONE YEAR LIMITED WARRANTY FOR THE BATTERY BACKUP SYSTEM The Chamberlain Group Inc Seller warrants to the first retail purchaser of this product for the residence in which this product is originally installed that it is free from defects in materials and or workmanship for a period of five years from the date of purchase except that the motor and belt are warranted to be free from defects in materials and or workmanship for the lifetime of the product while you own your residence and the Battery Backup System is warranted to be free from defects in materials and or workmanship for a period of one year from the date of purchase The proper operation of this product is dependent on your compliance with the instructions regarding installation operation and maintenance and testing Failure to comply strictly with those instructions will void this limited warranty in its entirety If during the limited warranty period this product
17. ADD REPROGRAM OR CHANGE A REMOTE CONTROL KEYLESS ENTRY PIN USING THE SMART CONTROL PANEL 1 Press the navigation button below to view the Features menu Use the navigation buttons to scroll to PROGRAM Select REMOTE or KEYPAD to program from the program menu Remote Control Pressthe button on the remote control that you wish to operate your garage door Keyless Entry Enter a 4 digit personal identification number PIN of your choice on the keyless entry keypad Then press the ENTER button The garage door opener lights will flash or two clicks will be heard when the code has been programmed Repeat the steps for programming additional remote controls or keyless entry devices If programming is unsuccessful program the remote using the learn button 2 3 4 1 Press 3 to continue Press E to continue CLOCK SETUP REMOTE TTC OFF MYQ DEVICE LOCK DISABLED LIGHT TO REMOTE xr JCI CO YA m 4 Operation Remote Control continued To Open the Door Manually PROGRAM A REMOTE CONTROL USING THE LEARN BUTTON 2 Press and immediately release the Learn button The Learn LED will glow steady for 30 seconds AWARNNG J 1 Locate the Learn Button Within 30 seconds To prevent possible SERIOUS INJURY or DEATH from a falling garage door 3 Press and hold the button on the remote control that you wish to use Release the button when e Ifpossible use emergency release handle to
18. ANT INSTALLATION INSTRUCTIONS A amp WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 9 Install wall mounted garage door control Install garage door opener ONLY on properly balanced and lubricated garage door An e within sightofthe garage door improperly balanced door may NOT reverse when required and could resultin SEVERE outofreach of children at minimum height of 5 feet 1 5 m INJURY or DEATH ALL repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener Place entrapment warning label on wall nextto garage door control Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener Place manual release safety reverse test label in plain view on inside of garage door e away from ALL moving parts of the door to avoid entanglement Upon completion of installation test safety reversal system Door MUST reverse on contact with a Install garage door opener 7 feet 2 13 m or more above floor 1 1 2 3 8 cm high object or a 2x4 laid flat on the floor Mount the emergency release within reach but at least 6 feet 1 83 m above the floor and Toavoid SERIOUS PERSONAL INJURY or DEATH from electrocution disconnect ALL electric avoiding contact with vehicles to avoid accidental release power BEFORE performing ANY service or maintenance NEVER connect garage door open
19. CHAMBERLAIN CONTENTS Belt Drive Battery Backup ener ener 1 4 Assembly eem 5 9 Garage Door Opener weno T 10 9 Install the Door Control 20 21 Install the Protector System 22 25 M 0 d e Is 26 28 Adjustments 29 31 e HD920 EV Battery 32 33 H D 930 EV ONKS ENEN WHEN THE PORER Operations e ee ea aa 34 e LW5000EV Wi Please read this manual and the enclosed safety materials carefully 35 Door Control 36 38 e WD962KEV i Fasten the manual near the garage door after installation 39 40 e WD962KPEV The door WILL NOT CLOSE unless the Protector System is connected and To Erase the Memory 40 e WD962MLEV property angna To Open the Door Manually 40 349544 Bi Periodic checks of the garage door opener are required to ensure safe operation Maintenance Mr fe one 41 B The model number label is located on the left side panel of your garage door Troubleshooting 42 43 opener Accessories 44 B This garage door opener is compatible with MyQ and Security 2 07 Warranty 45 accessories Repair Parts 46 47 DO NOT enable the Timer to Close feature if you are installing the garage door opener on a one piece door The Timer to Close is to be used ONLY with sectional doors FOR RESIDENTIAL USE ONLY Write down the following information for future
20. Clevis Pin 5 16 1 Ring Fastener Lock Washer 5 16 18 Nut 5 16 18 Ring Fastener Nut 5 1618 g Lock Washer 5 16 18 amp Clevis Pin Y S i Hex Bolt 5 16 18x7 8 Clevis Pin 5 16 x1 19 Installation STEP 10 Install the door control To prevent possible SERIOUS INJURY or DEATH from electrocution e Be sure power is NOT connected BEFORE installing door control e Connect ONLY to 12 VOLT low voltage wires To prevent possible SERIOUS INJURY or DEATH from a closing garage door Install door control within sight of garage door out of reach of children ata minimum height of 5 feet 1 5 m and away from ALL moving parts of door NEVER permit children to operate or play with door control push buttons or remote control transmitters Activate door ONLY when itcan be seen clearly is properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight until completely closed NEVER permit anyone to cross path of dosing garage door INTRODUCTION Compatible with MyQ enabled accessories see page 44 Your garage door opener is compatible with up to 2 MyQ door controls NOTE Older Chamberlain door controls and third party products are not compatible Install the door control within sight of the door ata minimum height of 5 feet 1 5 m where small children cannot reach and away from the moving parts of the door For gang box installations
21. Curved Door Arm 178B35 Pulley 144054 Door Bracket with 41A5047 1 41008 Clevis Pin and Fastener Master Link Rail 4145665 Emergency Release 41A2828 Rope and Handle Trolley Assembly as Header Bracket with 41h5047 2 U Bracket 12D598 1 Clevis Pin and Fastener Not Shown Remote Control 29B137 Wear Pads 183A163 Visor Clip Spring Retainer 41B4103 2 Safety Sensor Bracket 041A5266 3 Safety Sensor Kit 41A5034 Hardware Bag 041A7920 2 Receiving and sending Owner s Manual 114A4242 sensors with wire Straight Door Arm 178B34 White and Red White 41B4494 1 Wire Accessories 3V2030 Lithium Battery 10A20 Hanging Brackets 12B776 Description Part Number 1 Motion Detecting 41A7327 1 Control Panel Smart Control Panel 41A7305 1 Remote Control 953ESTD 46 Repa ir Parts Description Part Number Sprocket and Sprocket Cover with Screws Model HD930EV ONLY 04101751 Garage Door Opener Parts Sprocket and Sprocket Cover with Screws All other models 410589 2 End Panel with light socket 41D7639 Light Lens Model WD962KEV KPEV MLEV 41D7570 Model HD920EV HD930EV 41D7572 Model LW5000EV 349544 41D7571 Light Socket 410279 Transformer 41A7635 Cover Model WD962KEV KPEV MLEV 41A7620 6 Model HD920EV 41A7620 3 Model LW5000EV 349544 41A7620 Model HD930EV 041A7620 15 Motor with Travel Module 41D1739 1 End Panel for Receiver Logic Board with light socket 41D7638 Receiver
22. Door Top of Door Bracket Bracket Inside Garage Top Edge of Door Optional Placement For a door with no exposed framing or for the optional installation use lag screws 5 16 x1 1 2 not provided to fasten the door bracket Hardware not provided Top of Door Inside Garage Top Edge of Door Optional Placement Hardware not provided Installation STEP 9 Connect the door arm to the trolley Installation will vary according to the garage door type Follow the instructions which apply to your door OPTION A SECTIONAL DOORS IMPORTANT The groove on the straight door arm MUST face away from the curved door arm 1 Close the door Disconnect the trolley by pulling the emergency release handle 2 Attach the straight door arm to the outer trolley using the clevis pin Secure with the ring fastener 3 Attach the curved door arm to the door bracket using the clevis pin Secure with the ring fastener 4 Bring arm sections together Find two pairs of holes that line up and join sections Select holes as far apart as possible to increase door arm rigidity and attach using the bolts nuts and lock washers 5 Pull the emergency release handle toward the garage door opener until the trolley release arm is horizontal The trolley will re engage automatically when the garage door opener is activated NOTE Ifthe holes in the curved door armand the straight door arm do notalign reverse the straight door arm select two hole
23. Garage Door 12 Installation STEP 3 Attach the rail to the header bracket 1 Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you will need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring 2 Position the rail bracket against the header bracket 3 Align the bracket holes and join with a clevis pin as shown 4 Inserta ring fastener to secure HARDWARE Ring Fastener Clevis Pin 5 16 1 1 2 BN 5 13 STEP 4 Position the garage door opener CAUTION To prevent damage to garage door rest garage door opener rail on 2x4 placed on top section of door 1 Remove the packing material and lift the garage door opener onto a ladder 2 Fully open the door and place a 2x4 laid flat under the rail For one piece doors without tracks lay the 2x4 on it s side NOTE A 2x4 is ideal for setting the distance between the rail and the door If the ladder is not tall enough you will need help at this point Ifthe door hits the trolley when it is raised pull the trolley release arm down to disconnect the inner and outer trolley Slide the outer trolley toward the garage door opener The trolley can remain disconnected until instructed One piece door without tracks All other door types Installation STEP 5 Hang the garage door o
24. Logic Board Model HD930EV ONLY 045DCT125 Receiver Logic Board All other models 45DCT Line Cord Models manufactured before October 2012 41B135 1 Line Cord Models manufactured after October 2012 41B4245 1 Filter Board with Screws 41B7611 Models manufactured before October 2012 Terminal Block Models manufactured after October 2012 4143150 Travel Module 41A7114 7 Not Shown Wire Harness with Screws Models manufactured before 41B7418 October 2012 041B7610 1 Wire Harness with Screws Models manufactured after October 2012 2013 The Chamberlain Group Inc 114 4242 All Rights Reserved
25. Replace the batteries with j only 3V2032 coin cell batteries Insert battery positive side up Dispose of old batteries properly 41 NOTICE To complywith FCC and or Industry Canada IC rules adjustment or modifications of thistransceiverare prohibited THERE ARENO USER SERVICEABLE PARTS Anyd could void the usersauthorityto operate the hangesormodificationsnot expressly approved bythe party responsible for compliance equipment This device complies with Part 15 ofthe FCC rulesand IC RSS 210 Operation is subject to the following two conditions 1 this device may not cause harmfulinterference and 2 undesired operation This Class Bdigitalapparatus complies with his device must accept any interference received including interference that may cause anadian ICES 003 AVIS Lesr glesde la FCC et ou d Industrie Canada IC interdisent tout ajustement ou toute modification de ce r cepteur IL N EXISTE AUCUNEPIECE SUSCEPTIBLED TRE EN express ment approuv parla partie respon fonctionnerl quipement RETENUEPAR L UTILISATEUR Tout changement ou toute modification non sable de la conformit peut avoir pour r sultat d annuler autorit de l utiisateurde faire Cetappareilestconforme auxdispositions de la partie 15 du reglement de la FCC et de IC RSS 210 Son utilisation est assujettie auxdeuxoconditoins suivantes 1 disposi ifne peutcauserdesinterf rencesnuisibles et 2 ce dispositif doit accepterto
26. SOR IS NOT GLOWING 1 Make sure the sensor wire is not shorted broken 2 Make sure the sensors are aligned STEP 17 Ensure the door control is wired correctly Ifthe door control has been installed and wired correctly a message will display on the Smart Control Panel screen or the command LED on the Motion Detecting Control Panel will blink Adjustments Introduction WARNING Withouta properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on floor CAUTION To prevent damage to vehicles be sure fully open door provides adequate clearance Your garage door opener is designed with electronic controls to make setup and adjustments easy The adjustments allow you to program where the door will stop in the open UP and close DOWN position The electronic controls sense the amount of force required to open and close the door The force is adjusted automatically when you program the travel NOTE If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel it will reverse One Piece Doors Only When set
27. alled safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Safety reversal system MUST be tested every month e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on the floor 1 With the door fully open place a 1 1 2 inch 3 8 cm board or a 2x4 laid flat on the floor centered under the garage door 2 Operate the door in the down direction The door MUST reverse on striking the obstruction Ifthe door stops and does not reverse on the obstruction the down travel needs to be increased refer to Adjustment Step 1 Repeat the test When the door reverses on the 1 1 2 3 8 cm board or 2x4 laid flat remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment Ifthe garage door opener continues to fail the safety reversal test call a trained door systems technician 1 2 31 STEP 3 Test the Protector System WARNING Without a properly installed safety reversing sensor persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door 1 Open the door Place the garage door opener carton in the path of the door 2 Press the remote control push button to close the door The
28. appears to contain a defect covered by this limited warranty call 1 800 528 9131 toll free before dismantling this product You will be advised of disassembly and shipping instructions when you call Then send the product or component pre paid and insured as directed to our service center for warranty repair Please include a brief description of the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller s sole option You are responsible for any costs incurred in removing and or reinstalling the product or any component ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE APPLICABLE LIMITED WARRANTY PERIOD SET FORTH ABOVE FOR THE RELATED COMPONENT S AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING
29. cement instructions or reinforcement kit ke DET EIL NOTE Many door reinforcement kits provide for direct attachment of the clevis door arm In this case you will notneed the door bracket proceed to the next step HARDWARE Self Threading Screw 1 4 14x5 8 OPTION A SECTIONAL DOORS 1 Center the door bracket on the previously marked vertical centerline used for the header bracket installation Note correct UP placement as stamped inside the bracket 2 Position the top edge of the bracket 2 4 5 10 cm below the top edge of the door OR directly below any structural support across the top of the door 3 Mark drill holes and install as follows depending on your door s construction 16 Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket e 01111 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 1 e Alternately use two 5 16 18x2 bolts lock washers and nuts not provided Figure 2 Metal insulated or light weight factory reinforced doors e Drill 3 16 fastening holes Secure the door bracket using the self threading screws Figure 3 Wood Doors e Use top and bottom or side to side door bracket holes Drill 5 16 holes through the door and secure bracket with 5 16 18x2 carriage bolts lock washers and nuts not provided Figure 4 NOTE The
30. disengage trolley ONLY when garage door is the garage door opener lights blink or two clicks are heard When replacing the light lens cover CLOSED Weak or broken springs or unbalanced door could result in an open door falling ensure the antenna wires are hanging straight down rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall DISCONNECT THE TROLLEY 1 The door should be fully closed if possible 2 Pull down on the emergency release handle so the trolley release arm snaps to the vertical position The door can now be raised and lowered as offen as necessary LEARN LED To Erase the Memory ERASE ALL REMOTE CONTROLS AND KEYLESS ENTRIES 1 Press and hold the learn button on garage door opener until the learn LED goes out approximately 6 seconds All remote control and keyless entry codes are now erased Reprogram any accessory you wish to use ERASE ALL DEVICES Including MyQ enabled accessories 1 Press and hold the learn button on garage door opener until the learn LED goes out approximately 6 seconds TO RECONNECT THE TROLLEY 2 Immediately press and hold the learn button again until the learn LED goes out All codes are 1 Pullthe emergency release handle toward the garage door opener so the trolley release arm now erased snaps to the horizonta
31. eature off on J Adjust the contrast of the screen Operation Remote Control Your remote control has been programmed at the factory to operate with your garage door opener Older Chamberlain remote controls are NOT compatible see page 44 for compatible accessories Programming can be done through the door control or the learn button the garage door opener To program additional accessories refer to the instructions provided with the accessory or visit www chamberlain com If your vehicle is equipped with a Homelink you may require an external adapter depending on the make model and year of your vehicle Visit www homelink com for additional information TO ADD REPROGRAM OR CHANGE A REMOTE CONTROL KEYLESS ENTRY PIN USING THE MOTION DETECTING CONTROL PANEL 1 Pressthe LEARN button on the door control to enter Programming Mode 2 Pressthe LEARN button again the LED will flash once 3 Remote Control Pressthe button on the remote control that you wish to operate your garage door Keyless Entry Enter a 4 digit personal identification number PIN of your choice on the keyless entry keypad Then press the ENTER button The garage door opener lights will flash or two clicks will be heard when the code has been programmed Repeatthe steps for programming additional remote controls or keyless entry devices 2 The command LED will flash once again 1 The command LED will flash once 39 TO
32. ed through a series of menus on the screen and the navigation buttons Screen The screen will display the time temperature and current battery charge if applicable until the menu button is pressed and then it will display the menu options If there is a problem with the garage door opener the screen will display the Diagnostic Code Navigation Buttons Use the navigation buttons to make selections and program features FEATURES MENU Press the navigation button below MENU to view the Features menu CLOCK SETUP Set the time choose 12 or 24 hour clock and show hide clock ib ted Set the Timer to Close feature off on and set the time interval Lek before door closes PROGRAM Enable disable lock Add remote controls MyQ devices an extra remote button J to control your garage door opener lights or a keyless entry SETTINGS MENU 38 Pressthe navigation button below the down arrow till you see TEMPERATURE to view the Settings menu Display the temperature in Fahrenheit or Celsius and TEMPERATURE show hide the temperature LANGUAGE ENGLISH Select a language LIGHT SETTINGS CONTRAST ADJUST 50 Set duration for garage door opener light to stay on after EXIT 1 1 operation selectable range of 1 1 2 to 4 1 2 minutes Turn the Motion sensor off on and turn the entry light f
33. en obstructed or when the motion sensor on the door control detects movement in the garage These features can be disabled using the door control see page 35 My neighbor s remote control opens my garage door Erase the memory from your garage door opener and reprogram the remote control s The LEDs on the door control blink Ifyou have a Smart Control Panel installed and the TTC is set to a custom time press the ON button on the Premium Motion Detecting Control Panel to set the time properly My vehicle s Homelink is not programming to my garage door opener Depending on the make model and year of your vehicle an external adapter may be required Visit www homelink com for additional information 43 Accessories 7702CB Outside Quick Release Required for a garage with NO access door 8808CB 8 Foot 2 4 m Rail Extension To allow an 8 foot 2 4 m door to open fully 8810CB 10 Foot 3 m Rail Extension To allow a 10 foot 3 m door to open fully SD 41A6357 1 Standby Power System Battery a Provides backup power to the garage door opener e P 041A5281 1 Extension Brackets Optional For safety A reversing sensor installation to th Il or floor onto the wall or floor PILCEV MyQ Remote Light Control Control home lighting and garage doors with one remote For use with plug in lamps Synchronize to work with MyQ compatible garage door openers and remote controls
34. ensors do not affect the opening cycle The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction Using the Motion Detecting Control Panel SYNCHRONIZE THE DOOR CONTROL To synchronize the door control to the garage door opener press the push bar until the garage door opener activates it may take up to 3 presses Test the door control by pressing the push bar each press ofthe push bar will activate the garage door opener Push Bar HOLD OPEN LEARN Button 1 5 and Button TTC 10 Minute LOCK Button Tre LED LIGHT Button Motion Sensor MOTION DETECTING CONTROL PANEL FEATURES PUSH BAR Press the push bar to open or close the door LIGHTS Light Button Press the LIGHT button to turn the garage door opener lights on or off When the lights are turned on they will stay on until the LIGHT button is pressed again or until the garage door opener is activated Once the garage door opener is activated the lights will turn off after the specified period of time the factory setting is 4 1 2 minutes The LIGHT button will not control the lights when the door is in motion To change the amount of time the garage door opener lights will stay on Press and hold the LOCK button approximately 10 seconds until the garage door opener lights flash The time interval is indicated by the number times the garage door opener flashes 1 flash is 1 1 2 minutes e 2flas
35. er to power source until instructed to do so DO NOT enable the Timer to Close functionality if operating either one piece or swinging NEVER wear watches rings or loose clothing while installing or servicing opener They could be garage doors To be enabled ONLY when operating a sectional door caughtin garage door or opener mechanisms 10 Installation OPTIONAL CEILING MOUNT STEP 1 Determine the header bracket location WE T FOR HEADER BRACKET 4 WARNING To prevent possible SERIOUS INJURY or DEATH e Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling otherwise garage door might NOT reverse when required DO NOT install header bracket over Structural Supports Unfinished drywall Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry NEVER try to loosen move or adjust garage door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door might NOT reverse when required One piece door with horizontal track Installation procedures vary according to garage door types Follow the instructions which apply to your door N Header Wall 1 Close the door and mark the inside vertical centerline of the garage door Bias N L2 5 om 2 Extend the line onto the
36. fe and prevent damage disconnectthe battery when the garage door opener is unplugged for an extended period of time such as a summer or winter home NOTE When the garage door opener is in battery backup mode the garage door opener lights Timer to Close and Remote Close features are unavailable Battery status LED NOTE The Battery Status LED is most visible with the garage door opener light off Battery does not have to be fully charged to operate the garage door opener GREEN LED All systems are normal e Asolid green LED light indicates the battery is fully charged e Aflashing green LED indicates the battery is being charged ORANGE LED The garage door opener has lost power and is in battery backup mode e Asolid orange LED with beep sounding approximately every 2 seconds indicates the garage door opener is operating on battery power e Aflashing orange LED with beep sounding every 30 seconds indicates the battery is low RED LED The garage door opener s 12V battery needs to be replaced e A solid red LED with beep sounding every 30 seconds indicates the 12V battery will no longer hold charge and needs to be replaced Please call for replacement battery to allow your system to operate during a power outage Battery Status LED 33 Operation IMPORTANT SAFETY INSTRUCTIONS A WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS ALWAYS keep remote co
37. g installation and for testing the safety reversing sensors m SUPPORT BRACKET AND FASTENING HARDWARE Must be used if you have a finished ceiling in your garage m EXTENSION BRACKETS MODEL 041A5281 1 OR WOOD BLOCKS Depending upon garage construction extension brackets or wood blocks may be needed to install the safety reversing sensor FASTENING HARDWARE Alternate floor mounting of the safety reversing sensor will require hardware not provided m OUTSIDE QUICK RELEASE MODEL 7702CB Required for a garage with NO access door 0000 A m DOOR REINFORCEMENT Required if you have a lightweight steel aluminum fiberglass or glass panel door m RAIL EXTENSION KIT Required if your garage door is more than 7 feet 2 13 m high Preparation Carton Inventory Your garage door opener is packaged in one carton which contains the motor unit and all parts illustrated below Accessories vary depending on the garage door opener model purchased Depending on your model other accessories may be included with your garage door opener Instructions for these accessories will be attached to the accessory and are not included in this manual Save the carton and packing material until the installation and adjustment is complete The images throughout this manual are for reference only and your product may look different Header bracket Pulley Door bracket Curved door arm Straight door arm Packaged inside front rail section Trolle
38. he white wires into the white terminal on the garage door opener Insert the white black wires into the grey terminal on the garage door opener To insert or remove the wires from the terminal push in the tab with a screwdriver tip 24 Installation STEP 14 Wire the Safety Reversing Sensors continued OPTION B PRE WIRED INSTALLATION 1 Cutthe end ofthe safety reversing sensor wire making sure there is enough wire to reach the pre installed wires from the wall 2 Separate the safety reversing sensor wires and strip 7 16 inch 11 mm of insulation from each end Choose two of the pre installed wires and strip 7 16 inch 11 mm of insulation from each end Make sure that you choose the same color pre installed wires for each sensor 3 Connect the pre installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor For example the white wire would connect to the yellow wire and the white black wire would connectto the purple wire 4 Atthe garage door opener strip 7 16 inch 11 mm of insulation from each end of the wires previously chosen for the safety reversing sensors Twistthe like colored wires together 5 Insertthe wires connected to the white safety sensor wires to the white terminal on the garage door opener Insertthe wires that are connected to the white black safety sensor wires to the grey terminal on the garage door opener 25 1 Pre installed Safety reversing mE
39. he window as shown 4 Insert the idler bolt from the top through the rail and pulley Tighten with a 3 8 lock washer and nut underneath the rail until the lock washer is compressed Rotate the pulley to be sure it spins freely Locate the rail tab The rail tab is between the idler bolt and the trolley in the front rail section Use a flathead screwdriver and lift the rail tab until the tab is vertical 90 On HARDWARE Bolt Nut 3 8 Rail Bolt Y Tab Lock Washer 3 8 Nut 3 8 P Idler Pulley ue Trolley Connector Assembly STEP 4 Install the belt 1 Pull the belt around the idler pulley and toward the trolley The ribbed side must contact the pulley 2 Hook the trolley connector into the retaining slot on the trolley as shown Figure 1 3 With the trolley against the screwdriver dispense the remainder of the belt along the rail length toward the motor unit and around the sprocket Figure 2 The sprocket teeth must engage the belt 4 Check to make sure the beltis not twisted Connect the trolley threaded shaft with the master link Figure 3 e Push pins of master link bar through holes in end of belt and trolley threaded shaft e Push master link cap over pins and past pin notches e Slide clip on spring over cap and onto pin notches until both pins are securely locked in place 5 Remove the spring trolley nut from the threaded shaft 6 Insert the trolley threaded shaft through the h
40. hes is 2 1 2 minutes e 3 flashes is 3 1 2 minutes e 4 flashes is 4 1 2 minutes To cycle through the time intervals repeat the step above Light Feature The lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken e Deactivate Press and hold the LIGHT button approximately 10 seconds until the garage door opener lights turn on then off again e Activate Start with the garage door opener lights on Press and hold the LIGHT button approximately 10 seconds until the garage door opener lights turn off then on again Ifthe command LED is continuously blinking the LOCK feature needs to be deactivated Operation Motion Detecting Control Panel continued LOCK The LOCK feature is designed to prevent activation of the garage door opener from remote controls while still allowing activation from the door control and keyless entry This feature is useful for added peace of mind when the home is empty i e vacation e Activate Press and hold the LOCK button for 2 seconds The command LED will flash as long as the lock feature is activated and your handheld remote control will not operate your door at this time e Deactivate Press and hold the LOCK button again for 2 seconds The command LED will stop flashing and normal operation will resume TIMER TO CLOSE DO NOT enable TTC if operating a one piece door The TTC can be turned on or off and the time interval can be adju
41. il the door is in the desired UP position 3 Oncethe doorisin the desired UP position press and release the Adjustment Button The garage door opener lights will flash twice and the DOWN Button will begin to flash IMPORTANT NOTE For one piece door installations refer to page 29 4 Pressandhold the DOWN button until the door is in the desired DOWN position 5 Once the door is in the desired DOWN position press and release the Adjustment Button The 4 garage door opener lights will flash twice and the UP Button will begin to flash 6 Press and release the UP Button When the door travels to the programmed UP position the DOWN Button will begin to flash 7 Pressandrelease the DOWN Button The door will travel to the programmed DOWN position Programming is complete Ifthe garage door opener lights are flashing 5 times during the steps for Program the Travel the programming has timed out If the garage door opener lights are flashing 10 times during the steps for 6 Program the Travel the safety reversing sensors are misaligned or obstructed refer to page 28 When the sensors are aligned and unobstructed cycle the door through a complete up and down cycle using the remote control or the UP and DOWN buttons Programming is complete If you are unable to operate the door up and down repeatthe steps for Programming the Travel 30 Adjustments STEP 2 Test the Safety Reversal System WARNING Without a properly inst
42. itis not necessary to drill holes or install the drywall anchors Use the existing holes in the gang box NOTE Your product may look different than the illustrations HARDWARE Screw Screw exeo ses p Drywall Anchors 2 20 Qo 4 e or co 1 7 16 11 mm 1 Z 4 5 Strip 7 16 inch 11 mm of insulation from one end of the wire and separate the wires Connect one wire to each of the two screws on the back of the door control The wires can be connected to either screw If your garage is pre wired for the door control choose any two wires to connect note which wires are used so the correct wires are connected to the garage door opener in a later step Mark the location of the bottom mounting hole and drill a 5 32 inch 4 mm hole Install the bottom screw allowing 1 8 inch 3 mm to protrude from the wall Position the bottom hole of the door control over the screw and slide down into place Lift the push bar up and mark the top hole Remove the door control from the wall and drill a 5 32 inch 4 mm hole for the top screw Position the bottom hole of the door control over the screw and slide down into place Attach the top screw Installation STEP 11 Wire the door control to the garage door opener STEP 12 Attach the warning labels 1 Attach the entrapment warning label on the wall near the door control with tacks or staples HARDWARE 2 Attach the manual re
43. ket Section TO DOOR Cut Out Assembly STEP 2 Fasten the rail to the motor unit CAUTION To avoid SERIOUS damage to garage door opener use ONLY those bolts fasteners mounted in the top ofthe opener 1 Inserta 1 4 20x1 3 4 bolt into the cover protection bolt hole on the back end ofthe rail as shown Tighten securely with a 1 4 20 lock nut DO NOT overtighten 2 Remove the bolts from the top of the motor unit 3 Use the carton to support the front end of the rail 4 Place the U bracket flat side down onto the motor unit and align the bracket holes with the bolt holes 5 Fasten the U bracket with the previously removed bolts DO NOT use any power tools The use of power tools may permanently damage the garage door opener HARDWARE 7 NN 7 Y N Bolt 1 4 20x1 3 4 Lock Nut 1 4 20 Bolts Mounted in the garage door opener m 1 U Bracket Bolt 1 4 20x1 3 4 Cover Protection Bolt Hole Lock Nut 1 4 20 Assembly STEP 3 Install the idler pulley m pud Lay the belt beside the rail as shown Grasp the end with the hooked trolley connector and pass Zz approximately 12 30 cm of belt through the window Keep the ribbed side toward the rail and A allow itto hang until Assembly Step 4 7 2 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operation INCORRECT 3 Place the idler pulley into t
44. l position The trolley will reconnect on the next UP or DOWN operation Reprogram any accessory you wish to use either manually or by using the door control or remote control 40 Maintenance Maintenance Schedule EVERY MONTH e Manually operate door If itis unbalanced or binding call a trained door systems technician Check to be sure door opens and closes fully Adjust if necessary see page 29 e Testthe safety reversal system Adjust if necessary see page 29 EVERY YEAR e Oil door rollers bearings and hinges The garage door opener does not require additional lubrication Do not grease the door tracks e Test the battery backup and consider replacing the battery to ensure the garage door opener will operate during an electrical power outage see page 32 to test the battery backup The Remote Control Battery WARNING To prevent possible SERIOUS INJURY or DEATH e NEVER allow small children near batteries e If battery is swallowed immediately notify doctor To reduce risk of fire explosion or chemical burn e Replace ONLY with 3V2032 coin batteries e DO NOT recharge disassemble heat above 212 F 100 C or incinerate The 3V2032 lithium battery should produce power for up to 3 years If the battery is low the remote control s LED will not flash when the button is pressed To replace battery pry open the case firstin the middle 1 then at each side 2 and 3 with the visor clip
45. lease safety reverse test label in a visible location on the inside of the garage door Insulated Staple Not Shown 1 Run the white and red white wire from the door control to the garage door opener Attach the wire to the wall and ceiling with the staple not applicable for gang box or pre wired installations Do not pierce the wire with the staple as this may cause a short or an open circuit Strip 7 16 inch 11 mm ofinsulation from the end of the wire near the garage door opener 3 Connect the wire to the red and white terminals on the garage door opener If your garage is pre wired make sure you use the same wires that are connected to the door control To insert or release wires from the terminal push in the tab with screwdriver tip 7 16 11 21 Installation STEP 13 Install the Protector System WARNING Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor To prevent SERIOUS INJURY or DEATH from closing garage door e Correctly connect and align the safety reversing sensor This required safety device MUST NOT be disabled e Install the safety reversing sensor so beam is NO HIGHER than 6 15 cm above garage floor IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSORS The safety reversing sensors must be connected and aligned correctly before the garage door opener will move in the down direction The sending sensor with an amber
46. les spring assemblies and other hardware ALL of which are under EXTREME tension MUST be made by a trained door systems technician ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers This operator system is equipped with an unattended operation feature The door could move unexpectedly NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR DO NOT enable the Timer to Close functionality if operating either one piece or swinging garage doors To be enabled ONLY when operating a sectional door 16 SAVE THESE INSTRUCTIONS Operation Features Your garage door opener is equipped with features to provide you with greater control over your garage door operation MyQ MyQ technology uses a 900MHz signal to provide two way communication between the garage door opener and MyQ enabled accessories Your garage door opener is compatible with up to 8 MyQ accessories For Smartphone App control of your garage door opener and other MyQ accessories Chamberlain s MyQ Internet Gateway model CIGBU is required TIMER TO CLOSE TTC The Timer to Close feature automatically closes the door after a specified time period that can be adjusted using the door control DO NOT enable TTC if operating a one piece door TTC isto be used ONLY with sectional doors Factory defaultis setto off The garage door opener will beep and the lights will flash before closing the door The TTC feature will deactivate if
47. mer to Close or garage door monitor see page 35 My remote control will not activate the garage door e Verify the lock feature is not activated on the door control e Reprogram the remote control e ifthe remote control will still not activate the door check the diagnostic codes to ensure the garage door opener is working properly My door will not close and the light bulbs blink on my motor unit The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction e Verify the safety sensors are properly installed aligned and free of any obstructions SOLUTION Manually open and close the door Check for binding or obstructions such as a broken spring or door lock correct as needed If the door is binding or sticking contact a trained door systems technician If door is not binding or sticking attempt to reprogram travel refer to page 29 Communication error to travel module Check travel module connections replace travel module if necessary Safety sensors are misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensor s path while closing My garage door opener light s will not turn off when the door is open The garage door opener is equipped with a feature that turns the light on when the safety reversing sensors have be
48. ntrols out of reach of children NEVER permit children to operate or play with garage door control push buttons or remote controls ONLY activate garage door when it can be seen clearly itis properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight and away from people and objects until completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR NO ONE SHOULD GO UNDER A STOPPED PARTIALLY OPENED DOOR If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Use caution when using this release with the door open Weak or broken springs or unbalanced door could resultin an open door falling rapidly and or unexpectedly and increasing the risk of SEVERE INJURY or DEATH NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull garage door open or closed If rope knot becomes untied you could fall 34 After ANY adjustments are made the safety reversal system MUST be tested Safety reversal system MUST be tested every month Garage door MUST reverse on contact with 1 1 2 3 8 cm high object or a 2x4 laid flat on the floor Failure to adjust the garage door opener properly increases the risk of SEVERE INJURY or DEATH ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED see page 1 An improperly balanced door may NOT reverse when required and could resultin SEVERE INJURY or DEATH ALL repairs to cab
49. nut The lenses on both sensors should point toward each other Make sure the lens is not obstructed by the sensor bracket 1 2 Not provided Not provided No more than Pa 6 inches 15 cm cz E 4 Wing Nut 1 4 20 Carriage Bolt 1 4 20 1 2 23 OPTION FLOOR INSTALLATION Use an extension bracket not provided or wood block to raise the sensor bracket if needed 1 Carefully measure the position of both sensor brackets so they will be the same distance from the wall and unobstructed 2 Attach the sensor brackets to the floor using concrete anchors not provided 3 Slide the carriage bolt into the slot on each sensor Insert the bolt through the hole in the sensor bracket and attach with the wing nut The lenses on both sensors should point toward each other Make sure the lens is not obstructed by the sensor bracket Not provided Carriage Bolt 1 4 20x1 2 Installation STEP 14 Wire the Safety Reversing Sensors If your garage already has wires installed for the safety reversing sensors proceed to page 25 HARDWARE Insulated Staple Not Shown OPTION A INSTALLATION WITHOUT PRE WIRING 1 the wire from both sensors to the garage door opener Attach the wire to the wall and ceiling with the staples 2 Strip 7 16 inch 11 mm of insulation from each set of wires Separate the wires Twist the white wires together Twist the white black wires together 3 _ Insert t
50. ocket Mount the emergency release within reach but at least 6 feet 1 83 m above floor avoiding 3 Rotate the lens up to close NOTE Do notuse halogen short neck or specialty light bulbs as these may overheat the end panel or light socket Do not use LED bulbs as they may reduce the range or performance of your remote controls contact with vehicles to prevent accidental release and secure with a knot NOTE Ifitis necessary to cut the emergency release rope seal the cut end with a match or lighter to prevent unraveling Ensure the emergency release rope and handle are above the top ofall vehicles to avoid entanglement 15 Installation STEP 8 Install the door bracket CAUTION Fiberglass aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket Contact the garage door manufacturer or installing dealer for opener reinforcement instructions or reinforcement kit Failure to reinforce the top section as required according to the door manufacturer may void the door warranty A horizontal and vertical reinforcement is needed for lightweight garage doors fiberglass aluminum steel doors with glass panel etc not provided A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports A vertical reinforcement brace should cover the height of the top panel Contact the garage door manufacturer or installing dealer for opener reinfor
51. ole in the trolley HARDWARE Threaded Shaft with Spring Trolley Nut 111111 Figure 1 Trolley Connector Figure 2 Sprocket Figure 3 Front Rail Section Assembly STEP 5 Tighten the belt By hand thread the spring trolley nut on the threaded shaft until itis finger tight against the STEP 6 Install the sprocket cover trolley Do not use any tools Remove the screwdriver A WARN NG 2 Inserta flathead screwdriver tip into one of the nut ring slots and brace it firmly against the trolley 3 To avoid possible SERIOUS INJURY to finger from moving garage door opener Tighten the spring trolley nut with an adjustable wrench or a 7 16 open end wrench about a quarter turn until the spring releases and snaps the nut ring against the trolley This sets the e ALWAYS keep hand clear of sprocket while operating opener spring to optimum belt tension e Securely attach sprocket cover BEFORE operating 1 Position the sprocket cover over the sprocket as shown and fasten to the mounting plate with 8x3 8 hex screws provided You have now finished assembling your garage door opener Please read the following warnings before proceeding to the installation section HARDWARE Hex Screw 8x3 8 Nut Ring Nut Ring Packed with the sprocket cover BEFORE AFTER 1 1 1 4 2 5 cm 3 18 cm Hex Screw 8x3 8 Sprocket Cover Installation IMPORT
52. or obstructions such as a broken spring or door lock correct as needed Check wiring connections at travel module and at the logic board Replace travel module if necessary No movement only a single click Manually open and close the door Check for binding or obstructions such as a broken spring or door lock correct as needed Replace logic board if necessary Opener hums for 1 2 seconds no movement Manually open and close the door Check for binding or obstructions such as a broken spring or door lock correct as needed Replace motor if necessary 1 6 Door coasts after it has come to a complete stop Program travel to coasting position or have door balanced by a trained door systems technician 2 1 5 No movement or sound Replace logic board 3 2 Unable to setthe travel or retain position Check travel module for proper assembly replace if necessary 3 3 The battery status LED is constantly flashing green Battery backup charging circuit error replace the logic board 42 Troubleshooting DIAGNOSTIC CODE SYMPTOM Up Arrow Down Arrow Flash es Flash es 4 1 4 Door is moving stops or reverses 4 5 Opener runs approximately 6 8 stops and reverses 4 6 The garage door opener will not close and the light bulbs flash The garage door opener can beep for several reasons Operating on battery power or the 12 Vdc battery needs to be replaced see page 32 e Garage door opener has been activated through a device or feature such as Ti
53. or will stop and reverse to full open position and the opener lights will flash 10 times Ifthe door is fully open and the safety reversing sensors are not installed or are misaligned the door will not close from a remote control However you can close the door if you hold the button on the door control or keyless entry until the door is fully closed The safety reversing sensors do not effect the opening cycle ENERGY CONSERVATION For energy efficiency the garage door opener will enter sleep mode when the door is fully closed The Sleep mode shuts the garage door opener down until activated The sleep mode is sequenced with the garage door opener light bulb as the light bulb turns off the sensor LEDs will turn off and whenever the garage door opener lights turn on the sensor LEDs will light The garage door opener will not go into the Sleep mode until the garage door opener has completed 5 cycles upon power up LIGHTS The garage door opener light bulbs will turn on when the opener is initially plugged in power is restored after interruption or when the garage door opener is activated The lights will turn off automatically after 4 1 2 minutes An incandescent A19 light bulb 100 watt maximum or for maximum energy efficiency a 26W 100W equivalent compact fluorescent light CFL bulb may be used NOTE Do not use halogen short neck or specialty light bulbs as these may overheat the end panel or light socket Do not use LED bulbs as they may
54. pener 4 WARNING To avoid possible SERIOUS INJURY from a falling garage door opener fasten it SECURELY to structural supports of the garage Concrete anchors MUST be used if installing ANY brackets into masonry Hanging the garage door opener will vary depending on your garage Below are three example installations Your installation may be different For ALL installations the garage door opener MUST be connected to structural supports The instructions illustrate one ofthe examples below Finished Unfinished Ceiling Ceiling HARDWARE Lag Screw 5 16 9 1 5 8 Lock Washer 5 16 18 Nut 5 16 18 Hex Bolt 5 16 18x7 8 14 1 On finished ceilings use the lag screws to attach a support bracket not provided to the structural supports before installing the garage door opener 2 Make sure the garage door opener is aligned with the header bracket Measure the distance from each side of the garage door opener to the support bracket 3 Cutboth pieces of the hanging bracket to required lengths 4 Attach the end of each hanging bracket to the support bracket with appropriate hardware not provided 5 Attach the garage door opener to the hanging brackets with the hex bolts lock washers and nuts 6 Remove the 2x4 and manually close the door If the door hits the rail raise the header bracket 3 Lag Screw 5 16 9 1 5 8 4 5 Hex Bolt 5 16 18x7 8 Lock Washer 5 16 18 not
55. provided Nut 5 16 18 Installation STEP 6 Install the light bulbs STEP 7 Attach the emergency release rope and handle CAUTION To prevent possible OVERHEATING of the end panel or light socket Use ONLY A19 incandescent 100W maximum or compact fluorescent 26W maximum light bulbs WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door e f possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall DO NOT use incandescent bulbs larger than 100W DO NOT use compact fluorescent light bulbs larger than 26W 100W equivalent DO NOT use halogen bulbs DO NOT use short neck or specialty light bulbs 1 Insertone end ofthe emergency release rope through the handle Make sure that NOTICE is 1 Pull on the top sides of the light lens and rotate the light lens down right side up Tie a knotat least 1 inch 2 5 cm from the end of the emergency release 2 Insertan A19 incandescent 100W maximum or compact fluorescent 26W 100W equivalent 2 Insertthe other end of the emergency release rope through the hole in the trolley release arm light bulb into the light s
56. reduce the range or performance of your remote controls Light Feature The garage door opener is equipped with an added feature the lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is broken For added control over the light bulbs on your garage door opener see page 36 and 37 BATTERY BACKUP The battery backup system allows access in and out of your garage even when the power is out When the garage door opener is operating on battery power the garage door opener will run slower the light will not function the Battery Status LED will glow solid orange and a beep will sound approximately every 2 seconds Operation Using your Garage Door Opener The garage door opener can be activated through a wall mounted door control remote control wireless keyless entry or MyQ accessory When the door is closed and the garage door opener is activated the door will open If the door senses an obstruction or is interrupted while opening the door will stop When the door is in any position other than closed and the garage door opener is activated the door will close If the garage door opener senses an obstruction while closing the door will reverse Ifthe obstruction interrupts the sensor beam the garage door opener lights will blink 10 times However you can close the door if you hold the button on the door control or keyless entry until the door is fully closed The safety reversing s
57. rom the joints while assembling the rail Outer Trolley To avoid installation difficulties do not run the garage door opener until instructed to do so The front rail has a cut out window at the door end The front and back rail both have rail tabs These rail tabs MUST be on top of the rail when assembled 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 9 NOTE To prevent INJURY while unpacking the rail carefully remove the straight door arm stored within the rail section 2 Align the rail sections on a flat surface as shown and slide the tapered ends into the larger ones Tabs along the side will lock into place 3 Place the motor unit on packing material to protect the cover and rest the back end of the rail on top For convenience puta support under the front end of the rail 4 Asa temporary stop insert a screwdriver into the hole 10 25 cm from the front end of the rail as shown 5 Check to be sure there are 4 plastic wear pads inside the inner trolley If they became loose during shipping check all packing material Snap them back into position as shown y SLIDE TO STOPS ON TOP AND SIDES OF U BRACKET 6 Slidethe trolley assembly along the rail from the back end to the screwdriver 62 7 Slide the rail onto U bracket until it reaches all the stops on the top and sides of the U Front Rail brac
58. s as far apart as possible and attach using bolts nuts and lock washers If the straight door arm is hanging down too far you may cut 6 inches 15 cm from the solid end HARDWARE Clevis Pin 5 16 1 1 4 Clevis Pin 5 16 1 Hex Bolt 5 16 18 7 8 Ring Fastener Lock Washer 5 16 18 Nut 5 16 18 18 CORRECT Straight Door n Groove facing Oo Bolt 5 16 18x7 8 Clevis Pin 5 16 1 1 4 Clevis Pin 5 16 x1 Installation STEP 9 Connect the door arm to the trolley continued CORRECT INCORRECT OPTION B ONE PIECE DOORS IMPORTANT The groove on the straight door arm MUST face away from the curved door arm 1 Close the door Disconnect the trolley by pulling the emergency release handle Straight 2 Fasten the straight door arm and the curved door arm together to the longest possible length Door Arm with a 2 or 3 hole overlap using the bolts nuts and lock washers Groove Curved 3 Attach the straight door arm to the door bracket using the clevis pin Secure with the ring fastener facing out d 4 Attach the curved door arm to the trolley using the clevis pin Secure with the ring fastener 5 Pull the emergency release handle toward the garage door opener until the trolley release arm is horizontal HARDWARE Clevis Pin 5 16 x1 1 4 Clevis Pin 5 16 x1 Hex Bolt 5 16 18x7 8 Ring Fastener Fastener 7 2 Nut 5 16 18 d Lock Washer 5 16 18
59. sted to 1 5 and 10 minute intervals Once the TTC has been set and the door is open the selected close interval will blink and begin to count down to close the door e Activate Press and hold the ON button until one of the TTC LEDs light up Then press the ON button again to cycle through the time interval options the corresponding TTC LED will light for each time interval The garage door opener light bulbs will blink as confirmation Deactivate Press and hold the OFF button until all TTC LEDs turn off and a beep is heard from the motor unit Temporarily hold door open suspend TTC Press and release the HOLD OPEN button Press the HOLD OPEN button again to resume normal TTC operation PROGRAM Any compatible remote controls wireless keyless entry or MyQ accessories can be programmed to the garage door opener by pressing the Learn button Push Bar HOLD OPEN LEARN Button 1 5 and Button TTC 10 Minute LOCK Button TTC LED LIGHT Button Motion Sensor 37 Using the Smart Control Panel SYNCHRONIZE THE DOOR CONTROL To synchronize the door control to the garage door opener press the push bar until the garage door opener activates it may take up to 3 presses Testthe door control by pressing the push bar each press ofthe push bar will activate the garage door opener Push Bar Screen Navigation Buttons Motion Sensor LIGHT Button SMART CONTROL PANEL FEATURES
60. the wall or the floor The sensors should be no more than 6 inches 15 cm above the floor If the door track will not supportthe sensor bracket a wall installation is recommended Choose one ofthe following installations OPTION A DOOR TRACK INSTALLATION 1 Slidethe curved arms ofthe sensor bracket around the edge ofthe door track Snap into place so thatthe sensor bracketis flush againstthe track 2 Slide the carriage bolt into the slot on each sensor 3 Insert the bolt through the hole in the sensor bracket and attach with the wing nut The lenses on both sensors should point toward each other Make sure the lens is not obstructed by the sensor bracket No more than 6 inches 15 cm Carriage Bolt 1 4 20x1 2 Installation STEP 13 Install the Protector System continued OPTION B WALL INSTALLATION If additional clearance is needed an extension bracket not provided or wood blocks can be used Make sure each bracket has the same amount of clearance so they will align correctly 1 Position the sensor bracket against the wall with the curved arms facing the door Make sure there is enough clearance for the beam to be unobstructed Mark holes 2 Drill 3 16 inch pilot holes for each sensor bracket and attach the sensor brackets to the wall using lag screws not provided 3 Slide the carriage bolt into the slot on each sensor 4 Insertthe bolt through the hole in the sensor bracket and attach with the wing
61. ting the UP travel for a one piece door ensure that the door does not slant backwards when fully open UP If the door is slanted backwards this will cause unnecessary bucking and or jerking when the door is opening or closing INCORRECT Programming Buttons The programming buttons are located on the left side panel of the garage door opener and are used to program the travel While programming the UP and DOWN buttons can be used to move the door as needed PROGRAMMING BUTTONS UP Button Adjustment Button DOWN Button To watch a short instructional video on how to program the travel on your new garage door opener use your smartphone to read the QR Code 29 Adjustments STEP 1 Program the Travel UF oe UP Button Adjustment Button Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on floor DOWN Button While programming the UP and DOWN buttons can be used to move the door as needed 1 Press and hold the Adjustment Button until the UP Button begins to flash and or a beep is heard 2 Press and hold the UP Button unt
62. ute interf rence recue ycomprisune interf rence pouvant causerun fonctionnement non souhait Cet appareilnumerique de la classe Best con orme a la norme NMB 003 du Canada Troubleshooting Diagnostic Chart Your garage door opener is programmed with self diagnostic capabilities The UP and DOWN arrows on the garage door opener flash the diagnostic codes DIAGNOSTIC CODE SYMPTOM SOLUTION Up Arrow Down Arrow Flash es Flash es 1 1 The garage door opener will notclose and the light bulbs flash Safety sensors are notinstalled connected or wires may be cut Inspect sensor wires for a disconnected or cut wire 1 2 The garage door opener will not close and the light bulbs flash There isa shortor reversed wire for the safety sensors Inspect safety sensor wire atall staple and connection points replace wire or correct as needed 1 3 The door control will not function The wires for the door control are shorted or the door control is faulty Inspect door control wires at all staple and connection points replace wire or correct as needed 1 4 The garage door opener will not close and the light bulbs flash Safety sensors are misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensor s path while closing 1 5 Door moves 6 8 stops or reverses Manually open and close the door Check for binding
63. ventdamage to garage door and opener your garage door and or the garage door opener if you do not comply with the cautionary statementstnat ALWAYS disable locks BEFORE installing and operating the opener accompany it Read them carefully e ONLY operate garage door opener at 120 V 60 Hz to avoid malfunction and damage CAUTION Before you begin 1 Disable locks and remove any ropes connected to the garage door 2 Liftthe door halfway up Release the door If balanced it should stay in place supported entirely by its springs 3 Raise and lower the door to check for binding or sticking If your door Torsion Extension binds sticks or is out of balance call a trained door systems Spring Spring technician a 4 Check the seal on the bottom of the door Any gap between the floor and the bottom of the door must not exceed 1 4 inch 6 mm Otherwise the safety reversal system may not work properly 5 The opener should be installed above the center of the door If there is a torsion spring or center bearing plate in the way of the header bracket it may be installed within 4 feet 1 2 m to the left or right of the door center See page 11 Preparation Additional Items You May Need Tools Needed Survey your garage area to see if you will need any of the following items m 2 2X4 PIECES OF WOOD May be used to fasten the header bracket to the structural supports Also used to position the garage door opener durin
64. y NOTE Be sure to assemble the trolley before sliding onto rail Emergency release rope and handle Rail 1 front and 4 center sections Hanging brackets 2 Packaged inside the front rail section Garage door opener motor unit Sprocket cover and screws U bracket Belt Door control Motion Detecting Control Panel or Smart Control Panel Remote control The Protector System Safety reversing sensors with 2 conductor white and white black wire attached Sending Sensor 1 Receiving Sensor 1 and Safety Sensor Brackets 2 NOT SHOWN White and red white wire Owner s manual Hardware gt VOZErAc Preparation Hardware ASSEMBLY INSTALLATION Bolt Bolt 1 4 20x1 3 4 Self Threading Screw 1 4 14x5 8 2 Threaded Shaft with Spring Carriage Bott Wing Nut 10420 2 Hex Bolt 5 16 18x7 8 4 Trolley Nut 1 4 20x1 2 2 OY DAR Lock Washer Nut 5 16 18 5 Ring Fastener 3 Master Link 5 16 18 6 as E Lock Nut 4 o 1 4 20 7 mE DOOR CONTROL zi packed with the Screw 6 32x1 2 sprocket cover B TTT nse cm UU or Nut 3 8 Lock Washer 3 8 Assembly STEP 1 Assemble the rail and install the trolley door opener TO MOTOR UNIT CAUTION U Bracket E r To prevent INJURY from pinching keep hands and fingers away f

Download Pdf Manuals