Home

CFM M-0710 User's Manual

image

Contents

1. INSTALLATION PROCEDURE RECOMMENDED MAINTENANCE MODELS SEF 10 THROUGH SEF 30 When shutter is mounted to fan assembly 1 Cut square wall opening size 12 larger than fan blade diameter 2 From inside of building room center fan assembly over wall opening Fan must be positioned so that junction box is located at bottom and shutter is level and square with shutter blades opening upwards 3 Lag fan to wall through mounting holes in shutter gusset using appropriate fasteners by others 4 Rotate fan impeller by hand ensuring that it is unobstructed and rotates freely 5 Make electrical connections to fan junction box When shutter and fan assembly are mounted separately 1 Cut wall opening size 1 2 larger than fan blade diameter 2 From inside of building room center fan assembly over wall opening Fan must be positioned so that junction box is located at bottom 3 Lag fan to wall through wire hooks on guard using the appropriate fasteners by others 4 Apply caulking compound by others to rear of shutter gusset 5 From outside of building room center shutter over wall opening ensuring that shutter is level and square with shutter blades opening upwards 6 Lag shutter to wall through mounting holes in shutter gusset using appropriate fasteners by others 7 Rotate fan impeller by hand ensuring that it is unobstructed and rotates freely 8 Make electrical connections to fan j
2. Place fan assembly on shutter so that wire hooks on fan guard are centered over vibration isolators and nylon inserts Junction box must be positioned at bottom with shutter blades opening upwards 6 Secure fan assembly to shutter using screws and washers 7 Ensure that fasteners are snug Do not over tighten to avoid stripping nylon inserts MODEL SEF 30 Contents Pre assembled guard mount fan shutter shutter mounting hardware kit package of mounting screws To mount shutter to fan assembly 1 wN No Shutter mounting hardware kit includes 4 rubber vibration isolators 8 rubber inserts 8 screws 8 32 x 11 2 and 8 rubberized washers Insert screws into washers rubber side down Place rubber inserts into round holes of corner gussets at rear of shutter It may be necessary to twist and push or tap lightly to seat rubber inserts properly Place shutter face down gusset side up Center vibration isolators over rubber inserts Place fan assembly on shutter so that wire hooks on fan guard are centered over vibration isolators and nylon inserts Junction box must be positioned at bottom with shutter blades opening upwards Secure fan assembly to shutter using screws and washers Ensure that fasteners are snug Do not over tighten to avoid pulling out rubber inserts MODELS PEF 10 THROUGH PEF 30 Contents Pre assembled panel mount fan MODELS GEF 10 THROUGH GEF 30 Contents Pre assembled guard mount fan
3. CFM CONTINENTAL FAN INSTALLATION amp MAINTENANCE GUIDE SEF PEF amp GEF ExHAust FAns DIRECT DRIVE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION SEF SHUTTER MOUNT FAN THESE FANS ARE DESIGNED FOR GENERAL VENTILATION USE ONLY DO NOT USE TO EXHAUST CORRO SIVE HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS BEFORE INSTALLATION WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS 1 2 8 9 10 11 12 This fan has rotating parts Turn impeller by hand to ensure that it rotates freely Ensure that electrical service to fan is locked in the OFF position to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to service panel Do not re establish power supply until fan and activation device are completely installed Installation work including electrical wiring must be performed by a qualified person in accordance with all applicable codes and standards including local fire codes Check voltage at fan to see that it corresponds to fan motor nameplate rating Fan is intended to be hard wired to a properly rated electrical circuit and must be properly grounded Do not use an extension cord Fan motor is equipped with thermal overload protection which causes fan to shut off
4. automatically if motor overheats If this should happen immediately disconnect and lock power supply to fan Do not attempt to work on fan without discon necting power supply fan may restart without warning Fan should not be turned on and off rapidly Do not use fan with a solid state speed control device Do not allow fan to become wet or damp Do not block air intake or exhaust from fan Do not allow foreign objects to enter fan and come in contact with fan blades SPEED SELECTOR SWITCH Fan is equipped with either a 2 speed or 3 speed pull chain switch allowing user to select desired airflow Pulling a speed selector switch repeatedly will cause fan speed to cycle as follows 2 Speed Switch OFF FIRST SPEED OFF SECOND SPEED OFF 3 Speed Switch OFF HIGH MEDIUM LOW OFF PEF PANEL MOUNT FAN a GEF GUARD MOUNT FAN ASSEMBLY INSTRUCTIONS MODELS SEF 10 THROUGH SEF 24 Contents Pre assembled guard mount fan shutter shutter mounting hardware kit package of mounting screws To mount shutter to fan assembly 1 Shutter mounting hardware kit includes 4 rubber vibration isolators 4 nylon inserts 4 screws 12 x 1 and 4 rubberized washers 2 Insert screws into washers rubber side down 3 Place nylon inserts into square holes of corner gussets at rear of shutter 4 Place shutter face down gusset side up Center vibration isolators over nylon inserts 5
5. nd standards including local fire codes 4 Motor bearings are factory lubricated and do not require additional lubrication 5 Remove airborne contaminants that have settled on motor using an air hose or vacuum 6 Clean fan blades guard or shutter using a mild detergent Do not allow cleanser to come in contact with fan motor or electrical parts LIMITED WARRANTY This equipment is warranted to be free from defects in material and workmanship for a period of one 1 year from date of purchase Any units or parts which prove to be defective during warranty period will be repaired or replaced at Vendor s option Vendor is not responsible for any removal installation or transportation costs Motors are warranted separately by motor manufacturer for a period of one 1 year and should be returned to nearest authorized motor service center for repair All warranty claims must be processed through point of purchase WIRING PROCEDURE USA www continentalfan com Canada www aeroflo com Continental Fan Manufacturing Inc 203 Eggert Rd Buffalo NY 14215 Tel 716 842 0670 Toll 800 779 4021 Fax 716 842 0611 Aeroflo Inc 12 205 Matheson Blvd East Mississauga ON L4Z 3E3 Tel 905 890 6192 Toll 800 779 4021 Fax 905 890 6193 SEF PEF GEF 1 amp M 0710
6. unction box MODEL PEF 10 THROUGH PEF 30 1 Cut wall opening size 12 larger than fan venturi opening 2 From inside of building room center fan panel assembly over wall opening Fan must be positioned so that junction box is located at bottom 3 Lag fan to wall through mounting holes in panel using appropriate fasteners by others 4 Rotate fan impeller by hand ensuring that it is unobstructed and rotates freely 5 Make electrical connections to fan junction box agers GEF 10 THROUGH GEF 30 Cut wall opening size 12 larger than fan blade diameter From inside of building room center fan assembly over wall opening Fan must be positioned so that junction box is located at bottom 3 Lag fan to wall through wire hooks on fan guard using the appropriate fasteners by others 4 Rotate fan impeller by hand ensuring that it is unobstructed and rotates freely 5 Make electrical connections to fan junction box 1 When undertaking maintenance or service work ensure that electrical service to fan is locked in the OFF position to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to service panel 2 Do not re establish power supply until maintenance or service work has been completed 3 Maintenance or service work must be performed by a qual ified person in accordance with all applicable codes a

Download Pdf Manuals

image

Related Search

Related Contents

STIHL BT 121  Le bureau de l`AGREPI NORD - PICARDIE est heureux de vous  3200 PID Temperature controllers User Guide Manuale di uso Guía  MH-X20 Micro LED Spot moving head user manual  Ajuda imprimível do cliente da Web  L`Agence française de sécurité sanitaire des aliments (Afssa  MANUAL DEL USUARIO  Peavey XR 800F User's Manual  Magnavox 14MS2331/17, User's Manual  ZG10U English Manual  

Copyright © All rights reserved.
Failed to retrieve file