Home

Canon ES100 User's Manual

image

Contents

1. V Specifications Pickup Device Picture Element Horizontal resolution Sensitivity S N ratio Electronic shutter Auto Iris BLC AGC ON OFF Gamma Correction Video output Power source Sync Mode Lens Mount Dimension Operating Temperature Storage Temperature IIl Installation Instructions 1 3 inch interline transfer CCD 510x492 E EIA 500x580 C CCIR 420 TV lines 0 04 lux F 1 2 Over 48 dB Up to 1 10 000 Video Drive Yes Yes 0 45 1 0Vp p 75 ohm AC 198 264V Internal Sync C or CS with Ring 42x47x100mm 10 C to 50 C 40 C to 70 C MES1G00100 Remove the cover cap from the top of the lens mount If CS mount lens is used please also remove the C Mount Ring the 5mm thick ring on top of the lens mount e Screw the lens firmly onto the lens mount 4 Connect the video output of the camera to a B W monitor or other video device through a 75 ohm type coaxial cable with BNC female connector at camera end Plug the power cord to the outlet Power indicator LED should light if the power source is properly connected Once the image appears on the monitor adjust the focus and diaphragm of the lens to obtain the best picture If the subject is not in focus when adjusting focus of the lens do back focus adjustment as following i Set the focus ring of the lens to infinity position ii Take picture of subject at a distance more than 20m aw
2. ay from the camera iii Loosen the lens mount fixing screw located at bottom of the front panel by using the L wrench iv Turn the lens and the mount together so that the subject is in focus v Secure the lens mount fixing screw firmly again Mount the camera on the mounting bracket by using the mounting hole at bottom of the front panel If top mounting is required fix the top mounting base on top of the camera with two screws and then mount camera to mounting bracket Using Auto Iris Lens ES 100 Series INSTRUCTION MANUAL 1 3 B W CCD Cameras General The ES100 Series Cameras are compact full performance general purpose B W CCD Cameras which use high sensitive 1 3 B W interline transfer CCDs Charge Coupled Device ES100 with AC power cord has functions of ES on off AGC on off and BLC on off Audio feature is built in Il Precautions Do not expose the camera to humidity and dust If the camera is mounted outdoor a camera housing is required e Do not disassemble it or place it on an unstable base e Do not touch the surface of CCD sensor by hand directly When the camera is not in use put the cover cap on the lens mount e Never face the camera toward the sun e Use Auto iris lens or N D filter or set large F number of manual lens when the light intensity is very high in order to protect the sensitive CCD sensor e Use proper AC power source otherwise the camera will not functi
3. nce general purpose B W CCD Cameras which use high sensitive 1 3 B W interline transfer CCDs Charge Coupled Device ES100 with AC power cord has functions of ES on off AGC on off and BLC on off Audio feature is built in Il Precautions e Do not expose the camera to humidity and dust If the camera is mounted outdoor a camera housing is required e Do not disassemble it or place it on an unstable base e Do not touch the surface of CCD sensor by hand directly When the camera is not in use put the cover cap on the lens mount e Never face the camera toward the sun e Use Auto iris lens or N D filter or set large F number of manual lens when the light intensity is very high in order to protect the sensitive CCD sensor e Use proper AC power source otherwise the camera will not function correctly
4. nternal Sync Lens Mount C or CS with Ring Dimension 42x47x100mm Operating Temperature 10 C to 50 C Storage Temperature 40 C to 70 C MES1G00100 IV Using Special Features Using Auto Iris Lens For ES100 please use video drive iris lens Wire the cable of lens to Mini Plug according to the following table Pinl Pin2 Pin3 Pin4 12V VD IRIS GND GND Electronic Shutter ON OFF ES ON The camera continuously adjusts the shutter speed from 1 60 EIA 1 50 CCIR second to 1 10 000 second according to the luminance conditions of the scene ES OFF The shutter speed is fixed at 1 60 EIA 1 50 CCIR second Set ES OFF when auto iris lens is used or flicker is observed under a very bright fluorescent lamp Otherwise turn ES on for optimum performance Automatic Gain Control ON OFF AGC ON The sensitivity increases automatically when light is low AGC OFF A low noise picture is obtained under a low light condition Back Light Compensation When BLC is turn on the AGC ES and IRIS operating point is determined by averaging over the center area instead of entire field of view so that a dimly lit foreground object at center area can be clearly distinguished from brightly lit backgrounds BLC should not be used unless it is needed to compensate for back lit ES 100 Series INSTRUCTION MANUAL 1 3 B W CCD Cameras General The ES100 Series Cameras are compact full performa
5. on correctly IV Using Special Features For ES100 please use video drive iris lens Wire the cable of lens to Mini Plug according to the following table Pinl Pin2 Pin3 Pin4 ON 12V VD IRIS GND GND AGC orr BLC q Electronic Shutter ON OFF ES ON The camera continuously adjusts the shutter speed from 1 60 EIA 1 50 CCIR second to 1 10 000 second according to the luminance conditions of the scene ES OFF The shutter speed is fixed at 1 60 EIA 1 50 CCIR second Set ES OFF when auto iris lens is used or flicker is observed under a very bright fluorescent lamp Otherwise turn ES on for optimum performance Automatic Gain Control ON OFF AGC ON The sensitivity increases automatically when light is low AGC OFF A low noise picture is obtained under a low light condition Back Light Compensation When BLC is turn on the AGC ES and IRIS operating point is determined by averaging over the center area instead of entire field of view so that a dimly lit foreground object at center area can be clearly distinguished from brightly lit backgrounds BLC should not be used unless it is needed to compensate for back lit Ill Installation Instructions Remove the cover cap from the top of the lens mount If CS mount lens is used please also remove the C Mount Ring the 5mm thick ring on top of the lens mount e Screw the lens firmly onto the lens mount 4 Connect the video output of
6. the camera to a B W monitor or other video device through a 75 ohm type coaxial cable with BNC female connector at camera end Plug the power cord to the outlet Power indicator LED should light if the power source is properly connected Once the image appears on the monitor adjust the focus and diaphragm of the lens to obtain the best picture If the subject is not in focus when adjusting focus of the lens do back focus adjustment as following i Set the focus ring of the lens to infinity position ii Take picture of subject at a distance more than 20m away from the camera iii Loosen the lens mount fixing screw located at bottom of the front panel by using the L wrench iv Turn the lens and the mount together so that the subject is in focus v Secure the lens mount fixing screw firmly again Mount the camera on the mounting bracket by using the mounting hole at bottom of the front panel If top mounting is required fix the top mounting base on top of the camera with two screws and then mount camera to mounting bracket V Specifications Pickup Device 1 3 inch interline transfer CCD Picture Element 510x492 E EIA 500x580 C CCIR Horizontal resolution 420 TV lines Sensitivity 0 04 lux F 1 2 S N ratio Over 48 dB Electronic shutter Up to 1 10 000 Auto Iris Video Drive BLC Yes AGC ON OFF Yes Gamma Correction 0 45 Video output 1 0Vp p 75 ohm Power source AC 198 264V Sync Mode I