Bryant CK5B User's Manual

image

Contents

1. gt gt gt W gt WO w gt w w S ul u gt gt gt gt XT060024 24 7 8 18 3 4 CK5 A B XX060024 gt 26 15 16 14 1 4 In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabricate the coil enclosure to prevent air bypass GROSS COOLING CAPACITIES MBH INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR CFM EWB CFM Cubic Ft per Minute EWB Entering Wet Bulb F TC Gross Cooling Capacity 1000 Btuh SHC Gross Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh GROSS COOLING CAPACITIES MBH Continued SATURATED TEMPERATURE LEAVING EVAPORATOR F INDOOR COIL AIR CFM EWB CFM Cubic Ft per Minute EWB Entering Wet Bulb F LWB Leaving Wet Bulb F TC Total Cooling Capacity 1000 Btuh SHC Total Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh NOTES 1 Contact manufacturer for cooling capacities at conditions other than shown in table 2 Formulas sensible heat cap Leaving db entering db eav
2. 021 21 in Etc 024 24 1 2 in A Standard N Narrow T Transition W Wide X Max Cap Position A Painted B Embossed ISO 9001 C US ISO9001 Cert 12 100 7854 TMS CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI NOTE 1 Series designation is the 14th position of unit model number 58 NE 3 4 N NPT DRAIN IBA6 a u C A PEO SUCTION LINE a ee S SEN Eo W s 2 58 4 6 A 27 DNE D ud j 3 4 IN PLUGGED D DRAIN 0 NAL A KD 4 F G BE I 3 1 16 gt FRONT 118 DIMENSIONS In UNIT SERIES A B 12 9 16 RIGHT SIDE A97606 SHIPPING WEIGHT LB 28 1 2 CK5 A B XA018014 A 14 3 16 13 1 4 CK5 A B XA024014 14 3 16 13 1 4 XW024017 12 9 16 6 11 16 32 XA030014 9 1 16 8 13 16 10 13 16 11 3 16 13 1 16 10 1 2 10 1 2 10 7 8 12 3 4 12 11 16 21 3 8 12 15 16 14 15 16 XW048024 19 5 8 12 3 16 XA060024 22 5 8 16 1 2 060021 26 15 16 14 3 8
3. Every condensate pan features two 3 4 in fe male threaded brass insert connections The Bryant unique brass inserts provide for a leak free condensate line connection to prevent water damage Refrigerant Connections The coils are provided with proven sweat connections for leak free operation maintaining system reliability Burst Pressures These coils meet or exceed burst pressure of 2100 psi which is at least three to five times the pressure they will see in actual application External Piston Location Provides easy access to the piston metering device for quick installations and standard service pro cedures Liquid Line Bracket Holds the piston body in place for quick safe piston access without needing a back up wrench Neoprene Ring The ring installed inside the liquid line con nection is the best option for preventing refrigerant leaks and fu ture service calls Neoprene works with both Puron and R 22 Refrigerant Protective Tube Sheets Protect the durable copper tubing from being damaged during the manufacturing and installation process Warranty All Bryant coils feature a 1 year limited warranty on parts with additional extended warranties available for the system Form No PDS CK5A 18 1 C Coil MODEL NUMBER NOMENCLATURE K Cased N Coil 5 Upflow Downflow K 5 A X A 018 014 018 1 1 2 Ton 014 14 3 16 in 024 2 Ton 017 17 1 2 in 030 2 1 2
4. FURNACE N COILS CK5A CK5B Heating amp Cooling Systems Sizes A018 thru A060 This vertical design N coil is a furnace coil designed to provide the highest standards of reliability and durability The product is offered in a painted cased CK5A or an embossed cased CK5B version The cased coils are offered in standard over hang and wide configurations for use in multiple installation ap plications Additionally the cased coils are offered in a Transition configuration which is designed to fit two furnace widths without field modification Easy maintenance is provided as the coil slides out of the cabi net after removing the access door and service panel The coils are available in sizes 018 through 060 1 1 2 5 tons COMMON FEATURES Water Management The CK coil design does an excellent job of water management The coils are designed to avoid water blow off into the ducts by directing condensate away from the fins and into the drain pan The coils drain pan design provides improved condensate removal into the drain This improves in door air quality Durable Condensate Pan Each coil is equipped with a corro sion resistant condensate drain pan The condensate drain pan is designed with a slope to help ensure proper drainage im proved moisture removal and home comfort Compact Design Unique design offers as much as 2 in less in height to aid in tight installations Brass Inserts
5. ing entering ROSEN Leaving wb wb corresponding to enthalpy of air leaving coil hi wg total capacity Btuh 4 5 x CFM hiwa News where hgwg enthalpy of air entering coil 3 Direct interpolation is permissible Do not extrapolate 4 SHC is based on 80 F db temperature of air entering coil Below 80 F db subtract Correction Factor x CFM from SHC Above 80 F db add Correction Factor x CFM to SHC 5 All data points are based on 10 F superheat leaving coil 6 Bypass Factor 0 indicates no psychometric solution Use bypass factor of next lower EWB for approximation ENTERING AIR DRY BULB TEMPERATURE F 79 77 76 75 Under 75 BYPASS 81 83 84 84 Over 85 FACTOR Correction Factor Use formula shown below Interpolation is permissible Correction Factor 1 09 x 1 BF x db 80 UNIT SIZE COIL STATIC PRESSURE DROP In WC AIR QUANTITY CFM INDOOR COIL PISTONS CK5A CK5BA018 CK5A CK5BA024 W024 CK5A CK5BA030 W030 CK5A CK5BA036 N036 T036 W036 CK5A CK5BA042 N042 T042 CK5A CK5BA048 048 T048 W048 CK5A CK5BAO060 N060 T060 X060 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual including Uni
6. t Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting fewer calloacks Course descriptions and schedules are in our catalog CALL FOR FREE CATALOG 1 800 962 9212 Packaged Service Training Classroom Service Training A94328 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE bryant UNIT MUST INSTALLED ACCORDANCE WITH INSTALLATION INSTRUCTIONS Heating amp Cooling Systems Cancels PDS CJ5A 18 3 1999 Bryant Heating amp Cooling Systems 7310 W Morris St Indpls IN 46231 8 PRINTED IN U S A Catalog No 12CK 5A1 4 99