Home
Bryant 580J*16D User's Manual
Contents
1. 1 for location of the unit s nameplate See Fig 2 for details of the 17 digit model number CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could cause personal injury or death Before performing service or maintenance operations on unit always turn off main power switch to unit and install lockout tag Unit may have more than one power switch WARNING Nameplate Location C11014 Fig 1 Location of Unit Nameplate 580J 16D 3 580JE16D240A3A0AA 5 1 8 2 6 7 D 8 0 3 J 4 E 5 1 6 2 9 4 10 0 11 A 12 3 13 A 14 0 15 A 16 A 17 Model Number Position of Digit C11017 Fig 2 Example of Nameplate with Model Number 580J 16D 4 Table 1 Unit Wire Fuse or HACR Breaker Sizing Data UNIT NOM V Ph Hz IFM TYPE COMBUSTION FAN MOTOR POWER EXHAUST NO C O or UNPWR C O FLA FLA NO P E w P E pwrd fr unit MCA FUSE or HACR BRKR DISC SIZE MCA FUSE or HACR BRKR DISC SIZE FLA LRA FLA LRA 580J 16D 208 230 3 60 STD 0 48 3 8 68 3 80 71 396 72 1 80 76 400 MED 70 8 80 74 413 74 6 90 79 417 HIGH 77 8 75 8 100 100 82 80 424 81 6 79 6 100 100 87 84 428 460 3 60 STD 0 25 1 8 34 0 45 35 234 35 8 45 37 236 MED 35 0 45 37 243 36 8 45 39 245 HIGH 38 2 50 40 248 40 0 50 42 250 575 3 60 STD 0 24
2. Al E coat Al Cu T Al Al Al Cu Louvered Hail Guards U Al Al Cu Cu Louvered Hail Guards V Al Al E coat Al Cu Louvered Hail Guards W E coat Al Al Al Cu Louvered Hail Guards X E coat Al Al E coat Al Cu Louvered Hail Guards Voltage E 460 3 60 P 208 230 3 60 T 575 3 60 Refirg System Gas Heat Options A Standard One Stage Cooling Models Natural Gas Heat B Standard One Stage Cooling Models Low NOx Heat C Standard One Stage Cooling Models SS HX Heat D Two Stage Cooling Models F Two Stage Cooling Models and Stainless Steel Gas Heat Exchanger Heat Level Standard Stainless Steel 072 72 000 224 224 000 115 115 000 240 240 000 150 150 000 250 250 000 180 180 000 350 350 000 Low Nox 060 60 000 090 90 000 120 120 000 Indoor Fan Options 1 Standard Static Option 2 Medium Static Option 3 High Static Option C11016 2 SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when ins
3. protective device for the unit shall be fuse or HACR breaker Canadian units may be fuse or circuit breaker 2 Unbalanced 3 Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2 Use the following formula to de termine the percentage of voltage imbalance Voltage Imbalance 100 x max voltage deviation from average voltage average voltage Example Supply voltage is 230 3 60 AB 224 v BC 231 v AC 226 v Average Voltage 224 231 226 681 3 3 227 Determine maximum deviation from average voltage AB 227 224 3 v BC 231 227 4 v AC 227 226 1 v Maximum deviation is 4 v Determine percent of voltage imbalance Voltage Imbalance 100 x 4 227 1 76 This amount of phase imbalance is satisfactory as it is below the maximum allowable 2 IMPORTANT If the supply voltage phase imbalance is more than 2 contact your local electric utility company immediately 2011 Bryant Heating and Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 01 11 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No SS580J 02 Replaces New 580J 16D
4. 3 8 26 5 30 28 184 30 3 40 32 188 MED 26 5 30 28 184 30 3 40 32 188 HIGH 29 8 35 31 187 33 6 40 36 191 Table 1 Unit Wire Fuse or HACR Breaker Sizing Data cont UNIT NOM V Ph Hz IFM TYPE COMBUSTION FAN MOTOR POWER EXHAUST w PWRD C O FLA FLA NO P E w P E pwrd fr unit MCA FUSE or HACR BRKR DISC SIZE MCA FUSE or HACR BRKR DISC SIZE FLA LRA FLA LRA 580J 16D 208 230 3 60 STD 0 48 3 8 73 1 80 77 401 76 9 100 81 405 MED 75 6 100 80 418 79 4 100 84 422 HIGH 82 6 80 6 100 100 88 85 429 86 4 84 4 100 100 92 90 433 460 3 60 STD 0 25 1 8 36 2 45 38 236 38 0 50 40 238 MED 37 2 50 39 245 39 0 50 41 247 HIGH 40 4 50 43 250 42 2 50 45 252 575 3 60 STD 0 24 3 8 28 2 35 30 186 32 0 40 34 190 MED 28 2 35 30 186 32 0 40 34 190 HIGH 31 5 40 33 189 35 3 45 38 193 Legend and Notes for Table 1 LEGEND BRKR Circuit breaker CO Convenience outlet DISC Disconnect FLA Full load amps IFM Indoor fan motor LRA Locked rotor amps MCA Minimum circuit amps PE Power exhaust PWRD CO Powered convenient outlet UNPWR CO Unpowered convenient outlet NOTES 1 In compliance with NEC requirements for multimotor and combination load equipment refer to NEC Articles 430 and 440 the overcurrent
5. 580J 16D SINGLE PACKAGE ROOFTOP GAS HEATING ELECTRIC COOLING UNIT WITH PURONR R 410A REFRIGERANT SIZE 16 Electrical Data Supplement NOTE Read the entire instruction manual before starting the installation This supplement only applies to 580J size 16 units when the 13th digit of the Model Number is a 3 as shown in the Model Number Nomenclature diagram below Check the Unit Nameplate see Figs 1 amp 2 If the digit in the 13th position is not a 3 discard this document MODEL NUMBER NOMENCLATURE 5 8 0 J E 1 6 D 2 4 0 A 3 A 0 A A Model 580J Gas Heating Rooftop Unit Cooling Tons 16 15 ton 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Coil Options For Round Tube Plate Fin Condenser Coil Models Only Outdoor Indoor Hail Guard A Al Cu Al Cu B Precoat Al Cu Al Cu C E coat Al Cu Al Cu D E coat Al Cu E Coat Al Cu E Cu Cu Al Cu F Cu Cu Cu Cu M Al Cu Al Cu Louvered Hail Guards N Precoat Al Cu Al Cu Louvered Hail Guards P E coat Al Cu Al Cu Louvered Hail Guards Q E coat Al Cu E coat Al Cu Louvered Hail Guards R Cu Cu Al Cu Louvered Hail Guards S Cu Cu Cu Cu Louvered Hail Guards Coil Options For All Aluminum Novation Condenser Coil Models Only Outdoor Indoor Hail Guard G Al Al Al Cu H Al Al Cu Cu J Al Al E coat Al Cu K E coat Al Al Al Cu L E coat Al
6. talling Follow all safety codes Wear safety glasses and work gloves Use quenching cloths for brazing operations and have a fire extinguisher available Read these instructions thoroughly and follow all warnings or cautions attached to the unit Consult local building codes and appropriate national electrical codes in USA ANSI NFPA70 National Electrical Code NEC in Canada CSA C22 1 for special requirements It is important to recognize safety information This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand the signal words DANGER WARNING CAUTION and NOTE These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation ELECTRICAL HAZARD Failure to follow this caution may result in personal injury or product and property damage The electrical data contained in this document is only for use with 48TC size 16 units which display a 3 in the 13th position of the 17 digit model number as displayed on the unit s nameplate See Fig