Home

Briggs & Stratton 01655-3 User's Manual

image

Contents

1. a aaa BRIGGS amp STRATTON WATTS Operator s Manual Manuel d utilisation Model Mod le 01655 3 Questions Help is just a moment away Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Call Generator Helpline Appelez Ligne d assistance de G n rateur 1 800 743 4115 M F 8 5 CT web www briggsandstratton com LL WARNING L AVERTISSEMENT Before using this product read this manual and follow all Avant d utiliser ce produit veuillez lire le manuel et suivre Safety Rules and Operating Instructions toutes les directives relatives la s curit et l utilisation BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC Il JEFFERSON WISCONSIN U S A savor 10672006 0 24847 39454 2 SAFETY RULES SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Safety Rules ss cele span stele sei ess 2 4 Features and Controls 5 This is the safety alert symbol It is used to ASSOMNDIY 6 0 sa ese se tna ace nes done nie se hee ace eus dat 6 7 alert you to potential personal injury hazards Operation essee mrana ie EEE RESE 8 11 Obey all safety messages that follow this Product Specifications ses susavradnuieevenss 12 symbol to avoid possible injury or death Maintenance asie sisi eteduatasene sd 12 RE 13 The safety alert symbol is used with a signal word Bresse esse ene eee eee rene DANGER CAUTION
2. e In case of emergency contact a physician immediately and call 1 800 424 9300 for material safety information Fuel stabilizer contains 2 6 di tret butylphenol 128 39 2 and aliphatic petroleum distillate 64742 47 8 e Fuel tank may swell in storage if vent is closed When storing generator with fuel in the tank make sure the vent knob is turned fully counter clockwise e Store unit in clean and dry area TROUBLESHOOTING TROUBLESHOOTING Problem Cause Solution Circuit breaker is open Reset circuit breaker Poor connection or defective cord 2 Check and repair Generator is running but no AC set output is available Connected device is bad Connect another device that is in good condition Fault in generator Contact authorized service facility Short circuit in a connected load Disconnect shorted electrical load Generator runs good but bogs Generator is overloaded See Don t Overload Generator down when loads are connected Shorted generator circuit Contact authorized service facility Fuel valve is in the Off position 1 Turn fuel valve to the On position Generator will not start or starts Vent knob in fuel gauge is closed Open vent knob in fuel gauge and runs rough Low oil level 3 Fill crankcase to proper level or place generator on level surface Out of fuel Fill fuel tank Generator shuts down during operation Low oil level Fill crankcase to pro
3. Starting Wattage 8 500 watts Wattage ares san une eas save 5 500 watts AC Load Current At 120 Volts ss css rianne ensani 45 8 Amps AE 240 VOIES rss used 22 9 Amps Phase soe soso sdio ne seven the sise phase Rated Frequency 4 4 60 Hertz Fuel Tank Capacity 5 US gallons Shipping Weight 170 Ibs GENERAL MAINTENANCE RECOMMENDATIONS The Owner Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis that all discrepancies are corrected and that the unit is kept clean and properly stored NEVER operate a damaged or defective generator NOTE Should you have questions about replacing components on your Briggs amp Stratton generator please call 1 800 743 4115 for assistance Engine Maintenance See engine operator s manual for instructions Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals e Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosi
4. marrage dans l ordre num rique I Assurez vous que la g n ratrice se trouve sur une surface de niveau IMPORTANT Si la g n ratrice n est pas sur une surface de niveau elle pourrait ne pas d marrer ou encore s arr ter spontan ment 2 Pour ouvrir le bouton d a ration assurez vous qu il soit compl tement tourn dans le sens inverse des aiguilles d une montre Voir la Figure 12 la page 21 IMPORTANT Si vous ne l ouvrez pas l essence ne pourra pas entrer dans le tuyau et par cons quent le moteur ne pourra pas d marrer 3 Tournez la valve d essence sur la position On Marche Figure 15 Figure 15 Robinet d arriv e d essence R servoir d essence La valve est en position Off Arr t 4 D marrez le moteur selon les directives du manuel d utilisation du moteur ERTISSEMENT Une r troaction rapide de la corde du d marreur effet de recul tirera votre main et votre bras vers le moteur plus rapidement que vous ne pouvez rel cher la corde Vous risquez ainsi de subir des fractures des ecchymoses ou des entorses Lors du d marrage du moteur tirez lentement sur la corde jusqu ce que vous sentiez une r sistance et tirez alors rapidement afin d viter un effet de recul NE d marrez JAMAIS ni n arr tez jamais le moteur alors que des appareils lectriques y sont branch s et en fonction REMARQUE Si le moteur d marre apr s 3 essais mais qu il ne fonctionne pas ou qu i
5. n ratrice poss de une mise la terre du syst me qui raccorde les l ments du cadre de la g n ratrice aux bornes de mise la terre des prises de sortie C A La mise la terre du syst me est raccord e au fil neutre C A voir Description de quipement Exigences sp ciales Il se peut que la r glementation d une agence f d rale ou provinciale de sant et de s curit du travail des codes de s curit nationaux ou provinciaux ou des ordonnances r gissent l utilisation pr vue de la g n ratrice Veuillez consulter un lectricien qualifi un inspecteur en lectricit ou l agence comp tente de votre r gion e Dans certains territoires il faut enregistrer la g n ratrice aupr s du fournisseur de l alimentation de service e Des r glements additionnels r gissent peut tre l utilisation de la g n ratrice sur les chantiers de construction Branchement au syst me lectrique d un difice Seuls les lectriciens qualifi s sont habilit s brancher la g n ratrice au syst me lectrique d un difice pour en faire une source d alimentation de r serve Il faut que l alimentation de la g n ratrice soit isol e de l alimentation de service et que le branchement soit conforme toute la l gislation applicable et tous les codes de l lectricit ERTISSEMENT Le g n rateur produit une tension lev e NE PAS isoler le g n rateur de l installation lectrique risque de provoqu
6. unit vibrates excessively FEATURES AND CONTROLS KNOW YOUR GENERATOR Read this Operator s Manual and safety rules before operating your generator LU Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference Oil Fill Cap Dipstick Rocker Switch Fuel Tank 120 Volt AC 20 Amp Duplex Receptacle We lt gt RSS LX Se SSS XS RKRKXE SO X 120 240 Volt AC 30 Amp Receptacle XK KRL Double Pole Circuit Breaker AC Grounding Fastener Recoil Starter not shown Choke Lever Air Cleaner 120 Volt AC 20 Amp Duplex Receptacle May be Double Pole Circuit Breaker AC A double pole used to supply electrical power for the operation of circuit breaker is provided to protect all the receptacles 120 Volt AC 20 Amp single phase 60 Hz electrical lighting and generator against electrical overload appliance tool and motor loads Fuel Tank Capacity of 5 U S gallons 18 9 liters of fuel 120 240 Volt AC 30 Amp Locking Receptacle May Grounding Fastener If required please consult a be used to supply electrical power for the operation of qualified electrician electrical inspector or local agency 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine
7. WARNING a pictorial and or a Troubleshooting verore anase dad hea ace 28s 14 ne safety message to alert you to hazards DANGER indicates Warran Yne aaiae aaa matins oies 15 a hazard which if not avoided will result in death or EQU l PM ENT serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury D ESC RI PTI O N CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used RE Read this manual carefully and become without the alert symbol indicates a situation that could L familiar with your generator Know its result in equipment damage Follow safety messages to applications its limitations and any hazards avoid or reduce the risk of injury or death involved f A WARNING The generator is an engine driven revolving field alternating current AC generator It was designed to The engine exhaust from this product contains chemicals known to the State of California to cause supply electrical power for operating compatible electrical age cancer birth defects or other reproductive harm lighting appliances tools and motor loads The generator s revolving field is driven at about 3 600 rpm by a single CAUTION DO NOT exceed the generator s dll wattage amperage capacity See Don t Overload x Generator w Every effort has been made to ensure that information in Operators Manual El
8. air une partie de l eau restera dans les creux et craquelures de l isolation du bobinage du rotor et du stator Leau et l accumulation de salet sur ces bobinages internes du g n rateur r duiront progressivement la r sistance d isolation de ces bobinages AVERTISSEMENT CL 4 Unintentional peut r sulter dans feu ou lectrique 4 LORSQUE VOUS R GLEZ O R PAREZ VOTRE G N RATEUR D branchez toujours le c ble de bougie et placez le de fa on ce qu il ne soit pas en contact avec la bougie LORS DE TESTS D ALLUMAGE DU MOTEUR e Utilisez un v rificateur de bougies d allumage approuv NE v rifiez PAS l allumage lorsque la bougie d allumage est enlev e Pour Nettoyer le G n rateur e Se servir d un chiffon humide pour essuyer et nettoyer les surfaces ext rieures ATTENTION Un traitement inappropri du g n rateur risque de l endommager et de raccourcir sa dur e d utilisation N EXPOSEZ pas le g n rateur une humidit excessive de la poussi re de la salet ou des vapeurs corrosives N INS REZ aucun objet dans les fentes de refroidissement e Une brosse douce poils soyeux peut tre utilis e pour d gager la salet l huile durcie e Un aspirateur peut tre utilis pour ramasser la salet et les d bris qui ne sont pas coll s e On peut se servir d air comprim basse pression pas plus de 25 psi pour enlever la salet Inspectez les fente
9. alimentation lorsque vous tes debout dans l eau pieds nus ou avec les mains ou les pieds humides NE laissez pas des personnes non qualifi es ou des enfants se servir ou r parer le g n rateur A AVERTISSEMENT rA ity L essence et ses vapeurs sont extr mement inflammables et explosives Le feu ou l explosion risque de provoquer des blessures graves pouvant tre fatales LORS DE L AJOUT OU DE LAVIDANGE DU CARBURANT teignez le g n rateur et laissez le refroidir au moins 2 minutes avant de retirer le capuchon du r servoir de carburant Desserrez lentement le capuchon pour laisser la pression s chapper du r servoir Remplissez ou vidangez le r servoir d essence l ext rieur NE REMPLISSEZ PAS trop le r servoir Laissez l expansion de l essence Attend le carburant renvers pour s vaporer avant de d marrer le moteur loignez l essence des tincelles des flammes des veilleuses de la chaleur et de toute autre source d inflammation N ALLUMEZ PAS de cigarette ou ne fumez pas proximit de l appareil LORS DU D MARRAGE DE L QUIPEMENT Assurez vous que la bougie d allumage le silencieux le bouchon essence et le filtre air sont en place NE d marrez PAS le moteur lorsque la bougie d allumage est enlev e Attend le carburant renvers pour s vaporer avant de d marrer le moteur LORSQUE L QUIPEMENT FONCTIONNE NE penchez PAS le moteur ou l quipement vous risqueriez de renverser de l
10. by filtering dust and debris out of intake air Choke Lever Used when starting a cold engine having jurisdiction here Oil Fill Cap Dipstick Check and add oil to engine Recoil Starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch OFF engine ASSEMBLY ASSEMBLY Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel If you have any problems with the assembly of your generator please call the generator helpline at 1 800 743 4115 If calling for assistance please have the model revision and serial number from the serial number label available See Know Your Generator for location Unpacking the Generator l Set the carton on a rigid flat surface 2 Remove everything from carton except generator 3 Open carton completely by cutting each corner from top to bottom 4 Leave generator on carton to install handle Carton Contents Check all contents against those listed below Main unit Handle Locking 30 Amp plug Engine oil Two packets of fuel stabilizer Handle attachment hardware e Operator s manual e Engine operator s manual If any parts are missing or damaged call the generator helpline at 1 800 743 4115 Attach Handle to Unit Place handle assembly onto handle supports connected to main unit Make sure holes
11. cessaire pour d marrer les outils moteur lectrique ou les appareils lectrom nagers comme une scie circulaire ou un r frig rateur Parce que tous les moteurs ne d marrent pas au m me moment vous pouvez valuer la puissance de surtension totale en additionnant seulement le ou les article s pour le s quel s la puissance de surtension suppl mentaire est la plus importante la puissance nominale indiqu e l tape 2 Exemple Outil ou appareil lectrom nager Puissance de surtension suppl mentaire au Puissance nominale appareil en marche d marrage Climatiseur de 1200 1800 fen tre R frig rateur 800 1600 Cong lateur 500 500 T l viseur 500 Eclairage 75 watts 75 3075 watts au 1800 watts de surtension total pendant le fonctionnement Puissance nominale appareil en marche 3 075 Watts de surtension suppl mentaire 1 800 Puissance totale du g n rateur suppl mentaire 4 875 Gestion de la Consommation Afin de prolonger la dur e de vie de votre g n rateur et des accessoires il est important de faire attention lorsque vous ajoutez des charges lectriques votre g n rateur Aucun appareil ne doit tre branch aux prises du g n rateur avant de d marrer le moteur La mani re correcte et sans aucun risque de g rer la consommation du g n rateur est d ajouter s quentiellement des charges comme indiqu ci dessous 1 D marrez le moteur comme l indique ce ma
12. essence e Cette g n ratrice n est pas con ue pour tre utilis e dans de l quipement mobile ou les applications marines LORSQUE VOUS TRANSPORTEZ OU R PAREZ L EQUIPEMENT Le r servoir d essence doit tre VIDE ou le robinet d arr t de carburant doit tre a la position ferm e OFF pendant le transport ou la r paration D branchez le c ble de bougie LORSQUE VOUS ENTREPOSEZ L ESSENCE O UN QUIPEMENT AVEC UN R SERVOIR ESSENCE Entreposez le loin des appareils de chauffage des fours des chauffe eau des s cheuses ou de tout autre appareil lectrom nager disposant d une veilleuse ou de toute autre source d inflammation risquant d enflammer les vapeurs d essence A AVERTISSEMENT Cette g n ratrice ne satisfait pas aux normes U S Coast Guard Regulation 33CFR 183 et ne doit pas tre utilis e pour des applications marines L omission d utiliser une g n ratrice appropri e et approuv e par U S Coast Guard pourrait entra ner des blessures corporelles ou des dommages mat riels REGLES DE SECURITE A AVERTISSEMENT Une r troaction rapide de la corde du d marreur effet de recul tirera votre main et votre bras vers le moteur plus rapidement que vous ne pouvez relacher D Ve la corde Vous risquez ainsi de subir des fractures des ecchymoses ou des entorses Lors du d marrage du moteur tirez lentement sur la corde jusqu ce que vous sentiez une r sistance et tirez alor
13. excludes used reconditioned and demonstration equipment equipment used for prime power in place of utility power equipment used in life support applications and failures due to acts of God and other force majeure events beyond the manufacturers control BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI USA 198189E Rev 0 02 01 2006 REGLES DE SECURITE VEUILLEZ CONSERVER CES INSTRUCTIONS TABLE DES MATIERES R gles de S curit venise aged ess 16 18 Fonctions et Commandes 19 Assemblage sarcs sees tiuria od hier etai 20 21 Operation 60 0530 36e ed ghetto eke don 22 25 Caract ristiques du Produit 26 Entretiens uses dedans et us au see E 26 Rangement ase siens dents dut ds eae ee tite s 27 D pannage ascii ses dass ola ance ales guna alae Bieta 27 Garantie sau ss E a aia A sales amener 28 DESCRIPTION DE L QUIPEMENT TT Lisez avec soin ce manuel et familiarisez vous avec LU votre g n rateur Connaissez ses applications ses limitations et les dangers qu il implique Ce g n rateur est un g n rateur entrain par un moteur a champ magn tique rotatif produisant du courant alternatif c a Il a t con u pour fournir du courant lectrique pour faire marcher des charges compatibles d clairage d appareils m nagers d outil et de moteur Le champ tournant du g n rateur est entrain a 3 600 T M par un moteur monocylindrique ATTENTION N
14. le moteur D marrage recul Utilis pour d marrer le moteur manuellement Disjoncteur bipolaire C A Un disjoncteur bipolaire est fourni afin de prot ger toutes les prises et la g n ratrice contre les surtensions Filtre air Utilise un l ment de filtre du type sec et un pr filtre en mousse pour limiter le montant de salet et de poussi res entrant dans le moteur Interrupteur de starter Utilis lorsque vous faites un d marrage froid du moteur Comparez les illustrations avec votre g n rateur pour vous familiariser avec l emplacement des diverses commandes et r glages D marrage recul Interrupteur de starter K INNY LE A ee AS SSR 3 Xe X RS RRRS ieli SE 5M eae z R Disjoncteur bipolaire c a Prises de courant double de 120 Volts c a 20 Amp res peuvent tre utilis es pour fournir l alimentation lectrique de l clairage des lectrom nagers des outils ou des moteurs de 120 Volts 20 Amp res monophas s 60 Hz Prise de 120 240 Volts c a 30 Amp res Peut tre utilis e pour fournir du courant lectrique pour faire marcher des syst mes d clairage des appareils des outils ou des moteurs n cessitant 120 Volts et ou 240 Volts c a 30 Amp res monophas s 60 Hertz R servoir d essence R servoir d une capacit de 18 9 litres 5 gallons US Vis papillon de terre Si a exig veuille
15. le symbole d alerte indique une situation pouvant endommager l quipement Suivez les messages de s curit pour viter ou r duire les risques de blessures ou de mort A AVERTISSEMENT L chappement du moteur de ce produit contient des produits chimiques que l tat de Californie consid re comme causant le cancer des d formations la naissance ou d autres dangers concernant la reproduction Symboles de Danger et Moyens D A Manuel d Utilisation Choc lectrique Explosion Chimique Dangereux 4K Surface Chaude Emanations Toxiques REGLES DE SECURITE DANGER Le contenu est nocif ou mortel en cas d ingestion Eviter tout contact avec les yeux la peau et les v tements NE PAS avaler Eviter de respirer le brouillard ou les vapeurs La surexposition des yeux ou de la peau peut entra ner de l irritation Garder le stabilisateur hors de la port e des enfants Le stabilisateur d essence est un produit chimique dangereux En cas d INGESTION t l phoner imm diatement un m decin En cas d urgence communiquer imm diatement avec un m decin et t l phoner au 1 800 424 9300 pour obtenir des renseignements au sujet de la s curit du produit Le stabilisateur contient 2 6 di tret butylph nol 128 39 2 et distillat de p trole aliphatique 64742 47 8 AVERTISSEMENT Le g n rateur lorsqu il fonctionne produit du monoxyde de carbone un gaz toxique inodore et i
16. m decin Voir les instructions sur la mani re de remiser correctement le En cas d urgence communiquer imm diatement avec un m decin et moteur dans le manuel de l utilisation du moteur t l phoner au 1 800 424 9300 pour obtenir des renseignements au sujet de la s curit du produit Autres Id es de Remisage Le stabilisateur contient 2 6 di tret butylph nol 128 39 2 et distillat e Rangez toujours l unit avec la valve d essence sur la positon de p trole aliphatique 64742 47 8 Off Arr t Figure 15 ci dessus e Le r servoir risque de gonfler lorsqu il est rang si l a ration e Pour viter la formation de gomme dans le syst me est ferm e Lorsque vous rangez le g n rateur avec de d alimentation en carburant ou sur des pi ces essentielles du l essence dans le r servoir assurez vous que le bouton carburateur videz les trois r cipients de stabilisateur d essence d a ration est compl tement tourn dans le sens inverse des fournis dans le r servoir et remplissez les de carburant frais aiguilles d une montre Faites fonctionner l appareil pendant plusieurs minutes pour Conservez dans un endroit propre et sec faire circuler l adjuvant dans le carburateur Vous pouvez conserver l unit et le carburant pendant plus de 6 mois Vous pouvez acheter du stabilisateur d essence aupr s de l un de vos fournisseurs habituels D PANNAGE PROBLEMES CAUSE SOLUTION L un des disjoncteurs est ouvert R e
17. wet DO NOT allow unqualified persons or children to operate or service generator WARNING Running engines produce heat Temperature of muffler and nearby areas can reach or exceed 150 F 65 C Severe burns can occur on contact Exhaust heat gases can ignite combustibles structures or damage fuel tank causing a fire DO NOT touch hot surfaces and avoid hot exhaust gases Allow equipment to cool before touching Keep at least 5 ft 152 cm clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine to have a spark arrester maintained in effective working order complying to USDA Forest service standard 5100 1C or later revision In the State of California a spark arrester is required under section 4442 of the California Public resources code Other states may have similar laws CL 4 Unintentional sparking can result in fire or electric shock WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR e Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK e Use approved spark plug tester e DO NOT check for spark with spark plug removed WARNING Rapid retraction of starter cord kickback will pull hand and arm toward engine faster than ne you can let go Broken bones fractures bruises or spr
18. E PAS d passer la capacit en watts ou en Amp res du g n rateur Voir Ne Pas Surcharger le G n rateur pour l information sp cifique Tout a t mis en oeuvre pour que les informations contenues dans ce manuel soient exactes et jour Cependant nous se r serve le droit de changer d alt rer ou d am liorer le produit n importe quel moment sans avis pr alable Le Syst me de contr le de l mission du g n rateur est garanti pour des normes tablies par L Agence de protection de l environnement et le California Air Resources Board Pour des informations sur la garantie se reporter au manuel d utilisation du moteur R GLES DE S CURIT Ceci est la s ret le symbole vif Il est utilis pour vous alerter aux dangers de blessure personnels potentiels Ob ir tous messages de s ret qui suivent ce symbole viter la blessure ou la mort possibles Le symbole indiquant un message de s curit est accompagn d un mot indicateur DANGER ATTENTION AVERTISSEMENT d un message illustr et ou d un message de s curit visant vous avertir des dangers DANGER indique un danger qui s il n est pas vit provoquera des blessures graves voire fatales AVERTISSEMENT indique un danger qui s il n est pas vit peut provoquer des blessures graves voire fatales ATTENTION indique un danger qui s il n est pas vit peut provoquer des blessures mineures ou l g res Le mot ATTENTION lorsqu il est utilis sans
19. OAD THE GENERATOR See Don t Overload Generator CAUTION Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator OPERATION Stopping the Engine I Turn off and unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned on 2 Let engine run at no load for 30 seconds to stabilize internal temperatures of engine and alternator 3 Turn engine off according to instructions given in engine operator s manual 4 Move fuel valve to Off position RECEPTACLES The control panel is equipped with a flip up panel to keep the outlets clean and protected A double pole rocker switch circuit breaker is provided to protect all the receptacles and generator against electrical overload CAUTION Receptacles may be marked with rating value greater than generator output capacity NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator 120 Volt AC 20 Amp Duplex Receptacle The duplex receptacle F
20. Syst me de s curit Radio r veil AM FM Ouvre porte de garage 1 2 HP Chauffe eau lectrique de 40 gallons Outils de bricolage atelier Lampe de travail halog ne Pulv risateur sans air 1 3 HP Scie alternative Perceuse lectrique HP Scie circulaire 7 4 po Scie onglets 10 po Raboteuse de table 6 po Scie d tabli scie bras radial 10 po Compresseur d air 1 1 2 HP La puissance indiqu e ci dessus est approximative V rifiez les outils ou les appareils lectrom nagers pour conna tre leur puissance en watts 2000 CARACTERISTIQUES ET ENTRETIEN SPECIFICATIONS Puissance en watts commengant 8 500 Watts 8 5 kW Puissance en watts 5 500 Watts 5 5 kW Courant valu de Chargement de c a 120 VOIES uses a 45 8 Amp res 240 Volts parie eaae n ghee stds ass sente E 22 9 Amp res Phase 2 meiuedioihiss ob ee ee eli ado etwsedwads s l Fr quence Cia oe asses aeaa Ea fins diese 60 Hertz Volume du R servoir 5 Gallons US Poids l exp dition 170 Livres RECOMMANDATIONS G N RALES D ENTRETIEN Le propri taire utilisateur est responsable de la compl tion de toutes les t ches p riodiques d entretien en temps voulu il doit s assurer aussi que toutes anomalies sont corrig es et que la m
21. achine est gard e propre et remis e correctement NE JAMAIS faire marcher un g n rateur endommag ou d fectueux REMARQUE Devrait vous a des questions de remplacer de composants sur votre g n rateur de Briggs amp Stratton s il vous pla t appeler 1 800 743 4115 pour l assistance Entretien du Moteur Voit le manuel du utilisation de moteur pour les instructions ATTENTION vitez tout contact cutan prolong ou r p t avec l huile moteur usag e Il a t d montr que l huile moteur usag e risque de provoquer un cancer de la peau chez certains animaux de laboratoire Rincez consciencieusement les zones expos es avec de l eau et du savon GARDEZ HOS DE PORTEE DES ENFANTS NE POLLUEZ PAS CONSERVEZ LE SURPLUS RAPPORTEZ L HUILE USAGEE AUX CENTRES DE RECYCLAGE Entretien du G n rateur L entretien du g n rateur consiste le garder propre et sec Faire marcher et remiser l appareil dans un environnement propre et sec o celui l ne sera pas expos trop de poussi re de salet d humidit ou des vapeurs corrosives Les fentes de refroidissement par air du g n rateur ne doivent pas tre bouch es par de la neige des feuilles ou tout autre corps tranger REMARQUE NE PAS d utiliser un tuyau d arrosage pour nettoyer le g n rateur L eau peut entrer dans le syst me de carburation du moteur et causer des probl mes De plus si l eau entre par les fentes de refroidissement
22. ains could result When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on A CAUTION Excessively high operating speeds increase risk of injury and damage to generator Excessively low speeds impose a heavy load DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way CAUTION Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator CAUTION Improper treatment of generator can damage it and shorten its life Use generator only for intended uses If you have questions about intended use ask dealer or call 1 800 743 4115 Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots If connected devices overheat turn them off and disconnect them from generator Shut off generator if electrical output is lost equipment sparks smokes or emits flames
23. aire effectuer les r parations couvertes par la garantie et tenons nous excuser pour tout inconv nient subi Tout agent d un service apr s vente agr peut ex cuter les r parations couvertes par la garantie La plupart des r parations couvertes par la garantie sont trait es automatiquement cependant il arrive parfois que les demandes de service en vertu de la garantie soient non fond es Par exemple la garantie ne couvre pas les dommages caus s l quipement par une utilisation abusive par un manque d entretien p riodique durant l exp dition la manutention ou l entreposage ou en raison d une installation inad quate De m me la garantie sera annul e si la date de fabrication ou le num ro de s rie appos l y n ratrice portative a t enlev ou si l quipement a t chang ou modifi Durant la p riode de garantie le distributeur de service apr s vente agr r parera ou remplacera son gr toute pi ce qui apr s examen est trouv e d fectueuse la suite d une utilisation et d un entretien normaux La pr sente garantie ne couvre pas les r parations et les quipements suivants Usure normale Comme tout autre dispositif m canique les groupes lectrog nes d ext rieur n cessitent l entretien p riodiques de certaines pi ces pour fonctionner ad quatement La pr sente garantie ne couvre pas les frais de r paration des pi ces ou des quipements dont la dur e de vie utile a t d pass e
24. ar from open windows areas such as garages doors and vents Figure 5 Generator Clearance OPERATION OPERATING THE GENERATOR Starting the Engine Disconnect all electrical loads from the generator Follow these start instruction steps in numerical order Make sure unit is on a level surface IMPORTANT Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation 2 Turn the vent knob fully counter clockwise to open it See Figure 3 on page 7 IMPORTANT If you don t open the vent knob fuel will not flow into the fuel line causing the unit to not start 3 Turn the fuel valve to the On position Figure 6 The fuel valve handle should be horizontal pointing straight across for fuel to flow Figure 6 Fuel Shut off Valve Fuel Valve is shown in the Off position 4 Start the engine according to instructions given in the engine operator s manual A WARNING Rapid retraction of starter cord kickback will pull hand and arm toward engine faster than you can let go Broken bones fractures bruises or sprains could result k g e When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback e NEVER start or stop engine with electrical devices plugged in and turned on NOTE If engine starts after 3 pulls but fails to run or if unit shuts do
25. arranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country WARRANTY PERIOD Consumer Use 2 years Commercial Use 1 year Second year parts only The warranty period begins on the date of purchase by the first retail end user and continues for the period of time stated above Consumer Use means personal residential household use by a retail consumer Commercial Use means all other uses including use for commercial income producing or rental purposes Once equipment has experienced commercial use it shall thereafter be considered as commercial use for purposes of this warranty NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS amp STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the warranty is void if the ma
26. bon tat de fonctionnement ERTISSEMENT Unintentional peut r sulter dans feu ou lectrique LORSQUE VOUS R GLEZ OU REPAREZ VOTRE GENERATEUR D branchez toujours le c ble de bougie et placez le de fa on a ce qu il ne soit pas en contact avec la bougie LORS DE TESTS D ALLUMAGE DU MOTEUR e Utilisez un v rificateur de bougies d allumage approuv NE v rifiez PAS l allumage lorsque la bougie d allumage est enlev e ATTENTION Les vitesses de fonctionnement excessivement lev es augmentent les risques de blessure ou risquent d endommager le g n rateur Les vitesses extr mement lentes entra nent une charge importante NE TRAFIQUEZ PAS la vitesse r gul e Le g n rateur produit une fr quence nominale et une tension correctes lorsqu il fonctionne une vitesse r gul e NE modifiez le g n rateur d aucune fa on ATTENTION D passer la capacit de puissance ou d amp rage du g n rateur risque d endommager ce dernier et ou les autres appareils lectriques qui y sont branch s Voir la section Ne Pas Surcharger G n rateur D marrez le g n rateur et laissez le moteur se stabiliser avant de brancher les charges lectriques Branchez les charges lectriques en position ARR T puis remettez en position MARCHE teignez les charges lectriques et d branchez les du g n rateur avant de l arr ter ATTENTION Un traitement inappropri du g n rateur risque de l endommager
27. can cause severe burns or death WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Wait for spilled fuel to evaporate before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke Use clean fresh regular UNLEADED fuel with a minimum of 87 octane DO NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Turn the vent knob fully counter clockwise on the fuel gauge to open it Figure 3 Figure 3 Vent Knob Vent Knob 3 Clean area around fuel cap gauge remove cap Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion Figure 4 Figure 4 Fuel Expansion 5 Install fuel cap and wait for any spilled fuel to evaporate 6 If moving generator turn the vent knob fully clockwise on the fuel gauge to close it IMPORTANT The vent knob should be closed whenever you move the generator Vent Knob As is common with all plastic fuel containers the fuel tank supplied with this generator may swell or expand due to build up of fuel vapors when the vent knob is closed This tank is designed and has been tested to safely withstand pressure buildup The ballooning
28. condition is relieved by turning the vent knob fully counterclockwise OPERATION USING THE GENERATOR System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire see Equipment Description earlier in this manual Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction e In some areas generators are required to be registered with local utility companies If the generator is used at a construction site there may be additional regulations which must be observed Connecting to a Building s Electrical System Connections for standby power to a building s electrical system must be made by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes A WARNING Generator produces powerful voltage 2 Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for backup power notify utility company Use approved transfer equipment to isolate g
29. e pendant deux minutes pour stabiliser les temp ratures internes du moteur et du g n ratrice 3 Pour teindre le moteur suivez les instructions qui figurent dans le manuel d utilisation du moteur 4 R glez la vanne de combustible la position Off Arr t PRISES DE COURANT Le tableau de commande avant est quip avec un panneau d inverse en haut pour garder les sorties nettoient et prot g Un disjoncteur bipolaire est fourni afin de prot ger toutes les prises et la g n ratrice contre les surtensions ATTENTION Il se peut que la capacit nominale des prises soit sup rieure la puissance nominale de la g n ratrice NE tentez JAMAIS d alimenter un appareil dont l intensit nominale est sup rieure la capacit de la g n ratrice ou des prises NE surchargez PAS la g n ratrice Voir la section Ne Surchargez Pas G n ratrice 120 Volts c a 20 Amp res Prise de Courant Double Chaque prise de courant Figure 16 est prot g e contre la surcharge par un disjoncteur bipolaire avec interrupteur bascule Figure 16 120 Volts c a 20 Amp res Prise de Courant Double Utilisez chaque prise de courant pour faire fonctionner les charges lectriques de 120 volts c a monophas es 60 Hz n cessitant jusqu 2 400 watts 2 4 KWV 20 amp res Prise Verrouillage de 120 240 Volts c a 30 Amp res Utilisez une prise m le du NEMA L14 30 avec cette prise femelle Reliez une
30. ectrical shack this manual is accurate and current However we reserve the right to change alter or otherwise improve the product and this document at any time without prior notice The Emission Control System for this generator is Explosion Hazardous Chemical warranted for standards set by the Environmental Protection Agency and the California Air Resources Board For warranty information refer to the engine operator s manual SU 2 Toxic Fumes Kickback Hot Surface Copyright 2006 Briggs amp Stratton Power Products Group LLC All rights reserved No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs amp Stratton Power Products Group LLC SAFETY RULES DANGER Contents are harmful or fatal if swallowed Avoid contact to eyes skin or clothing DO NOT take internally Avoid breathing the mist or vapor Overexposure to eyes or skin can cause irritation Keep stabilizer out of the reach of children Fuel stabilizer is a hazardous chemical If SWALLOWED call physician immediately e In case of emergency contact a physician immediately and call 1 800 424 9300 for material safety information Fuel stabilizer contains 2 6 di tret butylphenol 128 39 2 and aliphatic petroleum distillate 64742 47 8 A WARNING Running generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can ca
31. enerator from electric utility Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Generator Location Generator Clearance PA fm Exhaust heat gases can ignite combustibles 4 structures or damage fuel tank causing a fire e Keep at least 5 ft 152 cm clearance on all sides of generator including overhead Place generator in a well ventilated area which will allow for removal of deadly exhaust gas Do not place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 5 Prevailing winds and air currents should be taken into consideration when positioning generator A DANGER Using a generator indoors WILL KILL YOU IN MINUTES Exhaust contains carbon monoxide a poison gas you cannot see or smell KK A NEVER use in the home ONLY use outdoors and or in partly enclosed f
32. ent des lois semblables aux terres f d rales Si vous quipez le silencieux d un pare tincelles il doit tre en bon tat de fonctionnement Branchement des Charges lectriques e Laissez le moteur se stabiliser et chauffer pendant quelques minutes avant de d marrer e Brancher et mettre en marche les charges lectriques de 120 et ou 240 Volts CA monophas es de 60 Hertz d sir es e NE PAS brancher des charges de 240 Volts des prises de 120 Volts e NE PAS brancher des charges triphas es au g n rateur e NE PAS brancher des charges de 50 Hertz au g n rateur NE PAS SURCHARGER LE GENERATEUR Voir la section Ne Pas Surcharger le G n rateur ATTENTION D passer la capacit de puissance ou d amp rage du g n rateur risque d endommager ce dernier et ou les autres appareils lectriques qui y sont branch s Voir la section Ne Pas Surcharger G n rateur D marrez le g n rateur et laissez le moteur se stabiliser avant de brancher les charges lectriques Branchez les charges lectriques en position ARR T puis remettez en position MARCHE teignez les charges lectriques et d branchez les du g n rateur avant de l arr ter OPERATION Arr t du Moteur D brancher toutes les charges lectriques des prises du g n rateur NE JAMAIS mettre en route ou arr ter le moteur alors que les appareils lectriques sont branch s et en marche 2 Laissez le moteur tourner vid
33. enues dans le manuel d utilisation du moteur REMARQUE Le champ tournant du alternateur est port par un roulement billes pr lubrifi et scell qui ne n cessite aucune lubrification suppl mentaire pendant toute la dur e de vie du roulement Ajoutez de l essence REMARQUE Le fonctionnement avec de l essence est certifi avec ce moteur essence Dispositif antipollution de l chappement EM Modifications de moteur L essence et ses vapeurs sont extr mement inflammables et explosives Le feu ou l explosion risque de provoquer des blessures graves pouvant tre fatales LORS DE L AJOUT DU CARBURANT teignez le g n rateur et laissez le refroidir au moins 2 minutes avant de retirer le capuchon du r servoir de carburant Desserrez lentement le capuchon pour laisser la pression s chapper du r servoir Remplissez le r servoir d essence l ext rieur NE REMPLISSEZ PAS trop le r servoir Laissez 1 5 pouce pour l expansion de l essence Attend le carburant renvers pour s vaporer avant de d marrer le moteur loignez l essence des tincelles des flammes des veilleuses de la chaleur et de toute autre source d inflammation N ALLUMEZ PAS de cigarette ou ne fumez pas proximit de l appareil l Utilisez de l essence sans plomb ordinaire propre et fra che avec un indice d octane d au moins 87 N utilisez PAS de carburant qui contient du M thanol NE m langez PAS avec de l huile 2 Tour
34. er des blessures ou m me d tre fatal pour les ouvriers lectriciens et de causer des dommages au g n rateur dus un backfeed d nergie lectrique Lorsque vous utilisez le g n rateur comme source d nergie de secours il est n cessaire d aviser les services publics d lectricit Utilisez un disjoncteur diff rentiel lorsque vous utilisez l appareil dans des endroits humides ou extr mement conductibles comme les terrasses en m tal ou les ouvrages m talliques NE touchez pas les fils d nud s ou les bo tiers N UTILISEZ pas le g n rateur avec des cordons lectriques us s effiloch s ou d nud s ou ab m s de quelque sorte que ce soit N UTILISEZ pas le g n rateur sous la pluie NE manipulez pas le g n rateur ou les cordons d alimentation lorsque vous tes debout dans l eau pieds nus ou avec les mains ou les pieds humides NE laissez pas des personnes non qualifi es ou des enfants se servir ou r parer le g n rateur Emplacement de la G n ratrice D gagement de la g n ratrice ERTISSEMENT La chaleur et les gaz d chappement peuvent enflammer des mat riaux combustibles et les structures ainsi que causer des dommages au r servoir d essence et entra ner un incendie e Laissez un d gagement d au moins 1 52 m 5 pi tout autour de la g n ratrice y compris au dessus Placez la g n ratrice dans un endroit bien ventil qui permet l limination des gaz d chappement morte
35. et de raccourcir sa dur e d utilisation NE vous servez du g n rateur que pour les utilisations pr vues Si vous avez des questions concernant les utilisations pr vues demandez votre distributeur ou appelez 800 743 41 15 Ne faites fonctionner le g n rateur que sur des surfaces horizontales N EXPOSEZ pas le g n rateur une humidit excessive de la poussi re de la salet ou des vapeurs corrosives N INS REZ aucun objet dans les fentes de refroidissement Si les appareils branch s sont en surchauffe teignez les et d branchez les du g n rateur Arr tez le g n rateur si la puissance lectrique est inexistante l quipement produit des tincelles de la fum e ou des flammes l unit vibre excessivement FONCTIONS ET COMMANDES CONNAISSEZ VOTRE GENERATEUR Lire ce manuel de l utilisation et les r gles de s curit avant de faire marcher votre g n rateur co Gardez ce manuel pour le consulter plus tard Bouchon rep re de remplissage d huile Commutateur a Bascule R servoir d essence Prise de courant double del 20 Volts c a 20 Amp res Prise de 120 240 Volts 30 Amp res c a Vis papillon de terre Bouchon rep re de remplissage d huile Ajoutez de l huile au moteur cet endroit Commutateur bascule Placez ce commutateur sur la position On Marche avant d utiliser le d marrage recul Placez le commutateur sur Off Arr t pour ARR TER
36. ie non dat e et toute garantie dont la date est ant rieure au 1er F vrier 2006 GARANTIE LIMIT E Briggs amp Stratton Power Products Group LLC r parera ou remplacera sans frais toutes pi ces d g n ratrice portative d fectueuses comportant un vice de mat riau ou un d faut de fabrication ou les deux En vertu de la pr sente garantie les frais de transport des produit soumises pour r paration ou remplacement sont la charge de l acheteur La pr sente garantie sera en vigueur durant les p riodes stipul es ci dessous et est assujettie aux conditions stipul es ci dessous Pour obtenir des services en vertu de la garantie veuillez consulter notre Outil de recherche d un Service apr s vente agr au http www briggspowerproducts com afin de trouver un distributeur de service apr s vente agr dans votre r gion IL N EXISTE AUCUNE AUTRE GARANTIE EXPRESSE LES GARANTIES IMPLICITES INCLUANT CELLES DE QUALIT MARCHANDE ET D ADAPTATION UN USAGE PARTICULIER SONT LIMIT ES UNE P RIODE D UN AN PARTIR DE LA DATE D ACHAT OU JUSQU LA LIMITE PERMISE PAR LA LOI TOUTE GARANTIE IMPLICITE EST EXCLUE LA RESPONSABILIT POUR DOMMAGES ACCESSOIRES O INDIRECTS EST EXCLUE DANS LA MESURE O UNE TELLE EXCLUSION EST PERMISE PAR LA LOI Certains tats provinces ou pays n autorisent aucune restriction sur la dur e d une garantie implicite et certains tats provinces ou pays n autorisent pas l exclusion ou la limitation des dommages con
37. igure 7 is protected against overload by a double pole rocker switch circuit breaker Figure 7 120 Volt AC 20 Amp Duplex Receptacle Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater Figure 8 You can use the same 4 wire cord if you plan to run a 120 Volt load Figure 8 120 240 Volt AC 30 Amp Receptacle 4 Wire Cord Set 240 120 120V W Neutral Y Hot X Hot NEMA LI 4 30 L Ground Green This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 2 750 watts of power at 22 9 Amps for 120 Volts 5 500 watts of power 5 5 kW at 22 9 Amps for 240 Volts The outlet is protected by a double pole rocker switch circuit breaker OPERATION DON T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps l Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of power your generator must produce to keep your items running See Figure 9 3 E
38. in handle align with holes on handle supports Figure 1 Figure Attach Handle to Base Supports NOTE It may be necessary to move the handle supports from side to side in order to align the handle so it will slide over the handle supports 2 Insert carriage bolts through holes from outside of the unit and attach a plastic knob from inside of unit Figure 2 Tighten by hand Figure 2 Secure Handle ASSEMBLY BEFORE STARTING THE ENGINE Add Engine Oil e Place generator on a level surface CAUTION Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure e Refer to engine manual for oil and fuel fill information e Damage to equipment resulting from failure to follow this instruction will void warranty e Use a long neck funnel when adding or changing oil e Refer to engine operator s manual and follow oil recommendations and instructions NOTE Check oil often during engine break in Refer to engine operator s manual for recommendations NOTE The alternator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Add Fuel NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications VA fe Fuel and its vapors are extremely flammable and 4 explosive Fire or explosion
39. iver 450 3075 Total 1800 Highest Color Television 27 500 Running Watts Surge Watts Personal Computer w 17 monitor 800 Total Rated Running Watts 3075 Highest Additional Surge Watts 1800 Total Generator Output Required 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting it s engine The correct and safe way to manage generator power is to sequentially add loads as follows With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly Other Security System 180 AM FM Clock Radio 300 Garage Door Opener 2 HP 480 Electric Water Heater 40 Gallon 4000 DIY Job Site Quartz Halogen Work Light 1000 Airless Sprayer 1 3 HP 600 Reciprocating Saw 960 Electric Drill 1 2 HP 1000 Circular Saw 7 1 4 1500 Miter Saw 10 1800 Table Planer 6 1800 Table Saw Radial Arm Saw 10 2000 Air Compressor 1 2 HP 2500 Wattages listed are approximate only Check tool or appliance for actual wattage SPECIFICATIONS AND MAINTENANCE SPECIFICATIONS
40. ixez la Poign e a l Appareil Principal Placez la poign e sur le support d j raccord l appareil principal Assurez vous que les trous de la poign e sont align s avec les trous du support Figure 10 Figure 10 Fixez la Poign e l Base Align s Trous Support de la Poign e REMARQUE peut tre n cessaire de d placer les supports de la poign e d un c t l autre afin d aligner la poign e et de la faire glisser sur les supports 2 Ins rez le boulon dans le trou du c t droit de la poign e en regardant l arri re de l appareil et fixez le bouton en plastique Figure 1 Vissez le bouton manuellement Figure Assur la Poign e ASSEMBLAGE AVANT LE DEMARRAGE DU MOTEUR Ajoutez de l huile moteur e Mettre le g n rateur sur une surface niveau ATTENTION Toute tentative de d marrer le moteur sans qu il ait t rempli avec l huile recommand e entra nera une panne de l quipement Reportez vous au manuel d utilisation du moteur au sujet de l huile La garantie sera annul e si des dommages l quipement sont entra n s par le manquement se conformer cette directive e Utilisez un entonnoir lorsque vous ajoutez ou changez l huile e Reportez vous au manuel d utilisation du moteur et suivez les directives et les recommandations relatives l huile REMARQUE V rifiez souvent l huile lors du rodage du moteur Consultez les recommandations cont
41. l s arr te assurez vous que la g n ratrice se trouve sur une surface de niveau et v rifiez si le carter du moteur contient suffisamment d huile Il se peut que cette g n ratrice soit munie d un syst me de protection en cas de bas niveau d huile Consultez le manuel du moteur ERTISSEMENT Les moteurs en fonctionnement produisent de la chaleur La temp rature du silencieux et des endroits proximit peuvent atteindre voire d passer 50 F CEKO Le contact de ces pi ces risque de causer de graves br lures La chaleur et les gaz d chappement peuvent enflammer des mat riaux combustibles et les structures ainsi que causer des dommages au r servoir d essence et entrainer un incendie NE TOUCHEZ PAS aux pi ces chaudes et vitez le contact avec les gaz d chappement Laissez l quipement refroidir avant de le toucher Laissez un d gagement d au moins 1 52 m 5 pi tout autour de la g n ratrice y compris au dessus Le Code of Federal Regulation CFR Title 36 Parks Forests and Public Property exige que de l quipement aliment par un moteur combustion interne soit dot d un pare tincelles et constamment maintenu en bon tat fonctionnement conform ment la norme de service 5100 1C de la USDA Forest ou une r vision de celle ci Dans l tat de la Californie un pare tincelles est requis en vertu de la section 4442 du California Public Resources Code II se peut que d autres Etats ai
42. la suite d une utilisation normale Installation et entretien La pr sente garantie ne couvre pas les quipements ou les pi ces qui ont fait l objet d une installation ou de modifications et de changements inad quats ou non autoris s d une mauvaise utilisation de n gligence d un accident d une surcharge d emballement d entretien inad quat de r paration ou d entreposage qui selon nous auraient nui la performance et la fiabilit du produit De plus la garantie ne couvre pas l entretien normal tel que les filtres air le r glage le nettoyage du circuit d alimentation et son obstruction caus e par l accumulation de produits chimiques de salet s de calamine de calcaire et ainsi de suite Exclusions suppl mentaires La pr sente garantie exclut les pi ces qui s usent telles que les les joints toriques les filtres etc ou tout mauvais fonctionnement r sultant d un accident d une utilisation abusive de modifications de changements ou d un entretien inad quat du syst me du gel ou d une d t rioration chimique La garantie du produit ne couvre pas les pi ces accessoires telles que les commencer piles les s rie de corde d adaptateur de g n rateur et les couverture d emmagasinage Est aussi exclu tout quipement us remis neuf ou de d monstration tout quipement utilis pour l alimentation principale en remplacement de l alimentation de service et tout quipement utilis pour l alimentation d apparei
43. ls N installez pas la g n ratrice dans un endroit o les gaz d chappement pourraient s accumuler et p n trer ou tre aspir s dans un difice qui pourrait tre occup Assurez vous que les gaz d chappement ne puissent entrer par une fen tre une porte une prise d a ration ou une autre ouverture qui pourrait leur permettre de s accumuler dans un espace restreint Figure 14 Tenez aussi compte des vents dominants et des courants d air au moment de choisir l endroit o vous installerez la g n ratrice ERTISSEMENT Le g n ratrice lorsqu il fonctionne produit du m de carbone un gaz toxique inodore et incolore xyde Le fait de respirer du monoxyde de carbone provoque des naus es des vanouissements ou peut tre fatal Faites fonctionner le g n ratrice SEULEMENT l ext rieur vitez que les gaz d chappement entrent dans un espace restreint par une fen tre une porte une prise d a ration ou toute autre ouverture NE FAITES PAS fonctionner le g n ratrice l int rieur d un b timent ou d un abri m me si les fen tres et les portes sont ouvertes y compris l int rieur du compartiment d un v hicule de plaisance Figure 14 D gagement de la g n ratrice G n ratrice typique montr Orifice d chappement OP RATION UTILISATION DU G N RATEUR D marrage du Moteur D connectez toutes les charges lectriques du g n rateur Suivez ces tapes d instructions de d
44. ls de maintien des fonctions vitales Cette garantie exclut toute d faillance due une catastrophe naturelle ou toute autre force majeure hors du contr le du fabricant BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI USA 198189F Rev 0 02 01 2006
45. nclencher le disjoncteur Le moteur marche mais il ne se 2 Probl me dans le g n rateur Contacter n gociant de service Autoris produit pas de courant c a dans Pauvre connexion ou rallonge d fectueuse 3 V rifier et r parer les prises fn ss P L appareil qui est branch est d fectueux 4 Brancher un autre appareil qui ne soit pas d fectueux Le moteur marche bien sans Court circuit dans une charge branch e 1 D brancher la charge en court circuit charge mais cale quand les Le g n rateur est surcharg Voir Ne Pas Surcharger G n rateur charges sont branch es Court circuit dans le g n rateur Contacter n gociant de service Autoris La valve est en position Arr t Tournez la valve d essence sur la position Marche Le moteur ne veut pas d marrer i O o d marre et marche mal Bas niveau d huile Remplissez le carter au niveau requis ou placez la g n ratrice sur une surface de niveau Plus d essence _Remplir le r servoir de carburant 1 Le moteur s arr te pendant la Bas niveau d huile Remplissez le carter au niveau requis ou marche placez la g n ratrice sur une surface de niveau Le moteur manque de puissance La charge est trop grande Voir Ne Pas Surcharger G n rateur GARANTIE DU PROPRIETAIRE D UN GENERATRICE PORTATIVE BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC partir du 1er F vrier 2006 la pr sente garantie remplace toute garant
46. ncolore Le fait de respirer du monoxyde de carbone provoque des naus es des vanouissements ou peut tre fatal e Faites fonctionner le g n rateur SEULEMENT l ext rieur vitez que les gaz d chappement entrent dans un espace restreint par une fen tre une porte une prise d a ration ou toute autre ouverture NE FAITES PAS fonctionner le g n rateur l int rieur d un b timent ou d un abri m me si les fen tres et les portes sont ouvertes y compris l int rieur du compartiment d un v hicule de plaisance AVERTISSEMENT Le g n rateur produit une tension lev e X NE PAS isoler le g n rateur de l installation lectrique _ risque de provoquer des blessures ou m me d tre fatal pour les ouvriers lectriciens et de causer des dommages au g n rateur dus un backfeed d nergie lectrique Lorsque vous utilisez le g n rateur comme source d nergie de secours il est n cessaire d aviser les services publics d lectricit Utilisez un disjoncteur diff rentiel lorsque vous utilisez l appareil dans des endroits humides ou extr mement conductibles comme les terrasses en m tal ou les ouvrages m talliques NE touchez pas les fils d nud s ou les bo tiers N UTILISEZ pas le g n rateur avec des cordons lectriques us s effiloch s ou d nud s ou ab m s de quelque sorte que ce soit N UTILISEZ pas le g n rateur sous la pluie NE manipulez pas le g n rateur ou les cordons d
47. nez le bouton d a ration compl tement dans le sens inverse des aiguilles d une montre sur la jauge pour le ouvrir Figure 12 Figure 12 Bouton d A ration 3 Nettoyez la partie autour du capuchon jauge du r servoir d essence enlevez le bouchon 4 Ajoutez lentement de l essence sans plomb ordinaire dans le r servoir d essence Faites attention pour ne pas trop remplir Laissez environ 4 cm 1 5 d espace de r servoir pour l expansion du carburant Figure 13 Figure 13 Espace de R servoir 5 Installez le bouchon essence et attend le carburant renvers pour s vaporer 6 Si d pla ant le g n rateur tournez compl tement le bouton d a ration dans le sens des aiguilles d une montre sur la jauge pour le fermer IMPORTANT Le bouton d a ration doit tre ferm chaque fois que vous d placez le g n rateur Bouton d a ration Comme il arrive souvent avec tous les r cipients d essence en plastique le r servoir d essence fourni avec ce g n rateur risque de gonfler ou de s agrandir cause de la formation de vapeurs d essence lorsque le bouton d a ration est ferm Le r servoir est con u et a t test pour pouvoir supporter sans risque la pression Vous pouvez supprimer le ph nom ne de ballonnement en tournant le bouton d a ration compl tement dans le sens inverse des aiguilles d une montre OP RATION UTILISATION DE LA G N RATRICE Mise la terre du syst me La g
48. nuel sans aucun appareil branch au g n rateur 2 Branchez et mettez en marche la premi re charge la plus importante de pr f rence 3 Laissez la puissance de sortie du g n rateur se stabiliser le moteur tourne r guli rement et les dispositifs branch s fonctionnent correctement 4 Branchez et mettez la charge suivante en marche 5 De nouveau laissez le g n rateur se stabiliser 6 R p tez les tapes 4 et 5 pour chaque charge suppl mentaire N AJOUTEZ JAMAIS de charges sup rieures la puissance du g n rateur V rifiez particuli rement les charges de surtension de la capacit du g n rateur comme il est indiqu ci dessus Figure 18 Tableau de R f rence de Puissance Puissance de surtension suppl mentaire au d marrage Puissance nominale appareil en marche Outil ou appareil lectrom nager Essentiels Ampoule lectrique de 75 watts 75 Surg lateur 500 500 Pompe de puisards 800 1200 R frig rateur cong lateur de 18 pi 800 1600 cu Pompe de puits eau 1 3 HP 1000 Air chaud air froid Courant continu 10000 BTU 1200 1800 Ventilateur de fen tre 300 600 Ventilateur d appareil de chauffage 800 2 HP Cuisine Four a micro ondes de 1000 watts Cafeti re Four lectrique a l ment unique Plaque de cuisson Salle familiale Lecteur de DVD CD Magn toscope R cepteur st r o T l viseur couleur de 27 po Ordinateur individuel avec moniteur de 17 po Autres
49. nufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified During the warranty period the Authorized Service Dealer at its option will repair or replace any part that upon examination is found to be defective under normal use and service This warranty will not cover the following repairs and equipment e Normal Wear Outdoor Power Equipment like all mechanical devices needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment e Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in our judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as air filters adjustments fuel system cleaning and obstruction due to chemical dirt carbon lime and so forth e Other Exclusions This warranty excludes wear items such as o rings filters etc or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Accessory parts such as generator adapter cord sets and storage covers are excluded from the product warranty This warranty
50. per level or place generator on level surface Generator lacks power Load is too high See Don t Overload Generator BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC PORTABLE GENERATOR OWNER WARRANTY POLICY Effective February 1 2006 replaces all undated Warranties and all Warranties dated before February 1 2006 LIMITED WARRANTY Briggs amp Stratton Power Products Group LLC will repair or replace free of charge any part s of the portable generator that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions stated below For warranty service find the nearest Authorized Service Dealer in our dealer locator map at www briggspowerproducts com THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM PURCHASE OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW Some states or countries do not allow limitations on how long an implied warranty lasts and some states or countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This w
51. rallonge quatre c ble de 250 Volts c a 30 Amp res ou davantage Figure 17 Vous pouvez utilisez la m me rallonge a quatre c bles si vous avez l intention de ne faire marcher qu une charge de 120 Volts Figure 17 Prise Verrouillage de 120 240 Volts c a 30 Amp res 240V 120V W Neutre Rallonge a 4 fils j Y Positif X Positif 7 7 Masse Vert Cette prise donne du courant a des charges de 120 240 Volts c a 60 Hertz monophas es n cessitant jusqu a 2 750 watts de puissance 2 75 kW 22 9 Amp res pour 120 Volts 5 500 watts de puissance 5 5 kW a 22 9 Amp res pour 240 Volts La prise est prot g e par un disjoncteur bipolaire avec interrupteur a bascule NEMA L14 30 OP RATION NE SURCHARGEZ PAS G N RATEUR Capacit Vous devez vous assurer que votre g n rateur puisse fournir suffisamment de puissance nominale appareil en marche et de surtension au d marrage pour les appareils que vous voulez alimenter en m me temps Suivez ces tapes simples l S lectionnez les appareils que vous voulez alimenter simultan ment 2 Additionnez la puissance nominale en marche de ces appareils Vous obtiendrez le montant de puissance que votre g n rateur doit produire pour faire fonctionner ces appareils Voir Figure 18 3 valuez le nombre de watts de surtension dont vous aurez besoin au d marrage La puissance de surtension est la br ve explosion de puissance n
52. s cutifs ou indirects Par cons quent les restrictions et exclusions d crites ci dessus pourraient ne pas s appliquer dans votre cas La pr sente garantie vous accorde certains droits l gaux sp cifiques et vous pourriez galement en avoir d autres qui peuvent varier d un tat ou d une province l autre et d un pays l autre P RIODE DE GARANTIE Usage par un consommateur 2 ans Usage des fins commerciales 1 an deuxi me an s pare seulement La p riode de garantie d bute la date d achat par le premier utilisateur final et se prolonge pour la dur e stipul e ci dessus Usage par un consommateur signifie utilisation domestique personnelle dans une r sidence par l acheteur au d tail Usage des fins commerciales signifie toute autre utilisation y compris des fins commerciales g n rant de revenus ou de location Aux fins de la pr sente garantie d s qu un quipement a t utilis commercialement une fois il est par la suite consid r comme tant d usage des fins commerciales POUR EXERCER LA GARANTIE SUR TOUT PRODUIT FABRIQU PAR BRIGGS amp STRATTON IL N EST PAS N CESSAIRE DE L ENREGISTRER CONSERVEZ LE REGU COMME PREUVE D ACHAT SI LORS D UNE RECLAMATION DE GARANTIE VOUS NE POUVEZ PROUVER LA DATE INITIALE DE L ACHAT NOUS UTILISERONS LA DATE DE FABRICATION DU PRODUIT COMME DATE DE R F RENCE POUR D TERMINER LA P RIODE DE GARANTIE PROPOS DE LA QUPEMENT GARANTIE Nous acceptons de f
53. s d air de refroidissement et les ouvertures sur le g n rateur Ces ouvertures doivent rester propres et non bouch es REMISAGE Le g n rateur doit tre mise en route au moins une fois tous les sept jours et doit marcher pendant au moins 30 minutes Si vous ne pouvez pas faire cela et que vous devez remiser le g n rateur pour plus de 30 jours utiliser les informations ci apr s comme guide pour pr parer votre appareil au remisage Remisage du G n rateur e Nettoyez le g n rateur comme indiqu la section Pour Nettoyer le G n rateur e V rifiez si les fentes d air de refroidissement et les ouvertures de votre g n rateur sont ouvertes et non bouch es ENTREPOSAGE ET DEPANNAGE A AVERTISSEMENT A DANGER Le contenu est nocif ou mortel en cas d ingestion Eviter tout contact avec les yeux la peau et les v tements NE PAS avaler Eviter de respirer le NE PAS placer une couverture d emmagasinage par dessus un brouillard ou les vapeurs La surexposition des yeux g n rateur chaud ou de la peau peut entra ner de l irritation Garder le stabilisateur hors de la port e des enfants Les couvertures d emmagasinage peuvent tre inflammables Laisser l unit refroidit pour un temps suffisant avant de placer la couverture sur l unit Le stabilisateur d essence est un produit chimique dangereux Remisage du Moteur 3 En cas d INGESTION t l phoner imm diatement un
54. s not for use in mobile equipment or marine applications WHEN TRANSPORTING OR REPAIRING EQUIPMENT e Transport repair with fuel tank EMPTY or with fuel shutoff valve OFF e Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors e This generator does not meet U S Coast Guard Regulation 33CFR 183 and should not be used on marine applications e Failure to use the appropriate U S Coast Guard approved generator could result in death or serious injury and or property damage SAFETY RULES A WARNING Generator produces powerful voltage Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are
55. s rapidement afin d viter un effet de recul NE d marrez JAMAIS ni n arr tez jamais le moteur alors que des appareils lectriques y sont branch s et en fonction AVERTISSEMENT Les moteurs en fonctionnement produisent de la chaleur La temp rature du silencieux et des endroits proximit peuvent atteindre voire d passer 50 F Ce Le contact de ces pi ces risque de causer de graves br lures La chaleur et les gaz d chappement peuvent enflammer des mat riaux combustibles et les structures ainsi que causer des dommages au r servoir d essence et entrainer un incendie NE TOUCHEZ PAS aux pi ces chaudes et vitez le contact avec les gaz d chappement Laissez l quipement refroidir avant de le toucher Laissez un d gagement d au moins 1 52 m 5 pi tout autour de la g n ratrice y compris au dessus Le Code of Federal Regulation CFR Title 36 Parks Forests and Public Property exige que de l quipement aliment par un moteur combustion interne soit dot d un pare tincelles et constamment maintenu en bon tat fonctionnement conform ment la norme de service 5100 1C de la USDA Forest ou une r vision de celle ci Dans l tat de la Californie un pare tincelles est requis en vertu de la section 4442 du California Public Resources Code II se peut que d autres tats aient des lois semblables aux terres f d rales Si vous quipez le silencieux d un pare tincelles il doit tre en
56. seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following guidelines to prepare it for storage Generator Storage e Clean the generator as outlined in Generator Cleaning e Check that cooling air slots and openings on generator are open and unobstructed WARNING h 4 PA Storage covers can be flammable DO NOT place a storage cover over a hot generator Let equipment cool for a sufficient time before placing the cover on the equipment Engine Storage See engine operator s manual for instructions Other Storage Tips e Always store unit with fuel shut off valve in the Off position Figure 6 earlier e To prevent gum from forming in fuel system or on essential carburetor parts empty entire contents of both supplied fuel stabilizer containers into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carburetor The unit and fuel can then be stored for up to 6 months Additional fuel stabilizer can be purchased locally DANGER Contents are harmful or fatal if swallowed Avoid contact to eyes skin or clothing DO NOT take internally Avoid breathing the mist or vapor Overexposure to eyes or skin can cause irritation Keep stabilizer out of the reach of children Fuel stabilizer is a hazardous chemical If SWALLOWED call physician immediately
57. stimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Rated Running Additional Surge Tool or Appliance 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Figure 9 Wattage Reference Chart Additional Surge Starting Watts Rated Running Watts Tool or Appliance Essentials Light Bulb 75 watt 75 Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator Freezer 18 Cu Ft 800 1600 Water Well Pump 1 3 HP 1000 2000 Heating Cooling Window AC 10 000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower 1 2 HP 800 Kitchen Microwave Oven 1000 Watt 1000 Watts Starting Watts Coffee Maker 1500 Window Air 1200 1800 Electric Stove Single Element 1500 Conditioner Hot Plate 2500 Refrigerator 800 1600 Family Room Deep Freezer 500 500 DVD CD Player 100 Television 500 VCR 100 Light 75 Watts 75 Stereo Rece
58. use nausea fainting or death Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure even if doors or windows are open including the generator compartment of a recreational vehicle RV A DANGER Using a generator indoors WILL KILL YOU IN MINUTES Exhaust contains carbon monoxide a poison gas you cannot see or smell AARSE NEVER use in the home ONLY use outdoors and or in partly enclosed far from open windows areas such as garages doors and vents VA me Fuel and its vapors are extremely flammable and 4 explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Wait for spilled fuel to evaporate before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT e Ensure spark plug muffler fuel cap and air cleaner are in place e DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT e DO NOT tip engine or equipment at angle which causes fuel to spill e This generator i
59. ve vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings A Ch Unintentional sparking can result in fire or electric shock WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR e Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed Generator Cleaning e Use a damp cloth to wipe exterior surfaces clean CAUTION Improper treatment of generator can damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots Use a soft bristle brush to loosen caked on dirt or oil Use a vacuum cleaner to pick up loose dirt and debris Inspect cooling air slots and opening on generator These openings must be kept clean and unobstructed STORAGE STORAGE The generator should be started at least once every
60. wn during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device See engine operator s manual Running engines produce heat Temperature of muffler and nearby areas can reach or exceed 150 F 65 C Severe burns can occur on contact Exhaust heat gases can ignite combustibles structures or damage fuel tank causing a fire DO NOT touch hot surfaces and avoid hot exhaust gases Allow equipment to cool before touching Keep at least 5 ft 152 cm clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine to have a spark arrester maintained in effective working order complying to USDA Forest service standard 5100 1C or later revision In the State of California a spark arrester is required under section 4442 of the California Public resources code Other states may have similar laws Connecting Electrical Loads e Let engine stabilize and warm up for a few minutes after starting e Verify the double pole circuit breaker is ON e Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads e DO NOT connect 240 Volt loads to the 120 Volt receptacles e DO NOT connect 3 phase loads to the generator DO NOT connect 50 Hz loads to the generator DO NOT OVERL
61. z consulter un lectricien qualifi un inspecteur en lectricit ou l agence comp tente de votre r gion ASSEMBLAGE ASSEMBLAGE Votre g n rateur exige que quelque assembl e et soit pr t pour l usage apr s il a t convenablement entretenu avec le p trole et le carburant recommand s Si vous avez n importe quels probl mes avec l assembl e de votre g n rateur s il vous pla t appeler le helpline de g n rateur 1 800 743 4115 Si vous t l phonez pour obtenir de l aide veuillez avoir disponibles les renseignements du tiquette du num ro de s rie num ro de mod le de r vision et de s rie Consultez la section Familiarisez vous avec la g n rateur pour d terminer son emplacement Enlever le g n rateur de la boite I Placez la bo te de carton sur une surface plane rigide 2 Enlevez tous les composants de la boite d exp dition l exception de la g n ratrice 3 Ouvrez la bo te d exp dition en coupant tous les coins du haut vers le bas 4 Laissez la g n ratrice dans la bo te d exp dition afin d installer les poign e Les Contenus De Bo te V rifient tous contenus e Le g n rateur e Le poign e e Prise de verrouillage 30 Amp res e Huile moteur e Deux paquets de stabilisateur d essence e Contr ler le mat riel d attachement e Manuel de l utilisation e Manuel du moteur Si certaines pi ces sont manquantes ou endommag es appelez le 1 800 743 4115 F

Download Pdf Manuals

image

Related Search

Related Contents

2012 Alberta Pork Congress Exhibitor Order Forms  Fleck 5600 Owner`s Manual  8 Port Hybrid Telephony Card User Manual  Schwangerschaftstest  Cables Direct NLNBL-003 cable lock  seca 878  Engines for Biogas (1988) (GTZ-Gate) (introductory  ACCELGUARD® 90 - Euclid Chemical    取扱説明書を必ずご参照ください 器 17 血液検査用器具 一般医療機器  