Home

Bionaire BAP336 User's Manual

image

Contents

1. BAP33605EM2 qxd 10 14 05 9 27 AM Page 1 TROUBLESHOOTING Problem f Solution System will not Confirm that the unit is plugged into a operate working electrical outlet Confirm that the Damper Switch 1 is in the ON position Check to make sure the system is on by pressing the Mode Button 2 Make sure that all bags have been removed from the filters Decreased airflow It should be noted that the air entering the room is designed to be at a low flow rate to prevent drafts Confirm that nothing is blocking the air inlet and outlet If SERVICE is displayed and the per formance bars are low the filters need to be cleaned See Routine Maintenance Instructions Check the condition of the filters See Routine Maintenance Instructions Drafts around Check to make sure that the foam seal window ing system Is correctly installed The leftover foam segments can be used to seal any remaining openings Routine Maintenance The Bionaire Air Exchange System is easy to use and maintain It includes filters that remove dust from air that is circulated through the system These filters will need to be cleaned or replaced with use The Service Indicator bar graph on the display 6 shows when service is needed The Service Indicator bar graph decreases and when the bars disappear the filters need to be cleaned The aver age duration between cleanings is about three months WARNING Do not attempt to repair or adjust any elect
2. for use with most window types 2 Extended Window Sill Hook for use with Andersen type windows Sash Insulation Extra Foam Figure 3 Figure 4 e Left Extender Right Extender Panel Panel Figure 6 6 Next you must customize the Plastic Extender Panels so that the Window Sealing Frame will fit securely in your window Each Plastic Extender Panel is divided into segments stamped with measurements between 26 to 38 inches These measurements represent the total inside measurement in inches of various sized windows See Figure 7 CAUTION Once you have removed segments from the Plastic Extender Panels the frame will only fit in windows equal to or less than the width you have selected Figure 7 Back Side Window Width Indicator 88 3 4 8 3 28 26 W Plastic Extender Segments Front Side 7 Use the black marker to mark the number on each Plastic Extender Panel that is closest to but not greater than the measurement you recorded in Step 1 For example if your win dow is 33 inches wide mark the number 32 See Figure 8 8 Snap off each segment of the front of the Plastic Extender Panel with a higher number than you marked If you marked 32 in TISS step 8 you only will remove the segments for 38 36 and 34 and three segments from the back of the Plastic Extender Panel Use a forward and backward motion to remove the
3. any plastic bags before use Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs near heat registers radiators stoves or heaters To protect against electrical hazards DO NOT immerse in water or other liquids Do not use near water e Close supervision is necessary when any appliance is used by or near children or disabled persons Avoid contact with moving parts Always unplug the product before moving it opening the grill changing the filters cleaning or whenever the product is not in use Be sure to pull by the plug and not the cord e NEVER drop or insert any object into any openings other than instructed in this manual e DO NOT operate any appliance with a damaged cord or plug if motor fan fails to rotate after the appliance malfunctions or if it has been dropped or damaged in any manner Return appliance to manufacturer for examination electrical or mechanical adjustment or repair e Use appliance only for intended household use as described in this manual Any other use not recommended by the manufacturer may Cause fire electric shock or injury to persons The use of attachments not recommended or sold by J CS THG LLC may cause hazards e NEVER block the air openings grills outlets or place objects that would cause blockage of the air intake exhaust openings e Keep unit away from heated surfaces and open flames e DO NOT attempt to repair or adjust any electrical
4. grill See Figure 27 Fea e Put the unit with the front grill face down on the surface e Place the grill on the rear of the unit with the thumb opening toward the bottom power cord side of the unit e Gently press down on the edges of the grill until all edges are securely latched 18 Put the unit on the table in the normal position and replace the front grill See Figure 28 19 Slide the Air Exchange Unit into the Window Sealing Frame and push until it locks in place 20 Insert the electrical plug into the outlet and turn the unit on 21 Reset the service indicator by inserting the tip of a paper clip into the Service Reset Hole 5 and gently pressing the button inside the hole 22 The Service Indicator bar graph should reappear Figure 28 Replacement Filters Order these filters by calling 1 800 253 2764 Filter Part Quantity Description Number Required APF18 Electrostatic Filter 2 Tab Optional APF19 Washable Foam Filter 1 Tab APF20 Washable Foam Filter 2 Tab Service Instructions If you need to exchange the unit within 30 days of purchase please return it in its original carton with the sales receipt to the store from which it was purchased If you need to return the unit beyond 30 days after you purchased it review the warranty information provided with the unit and call 1 800 253 2764 for warranty service You will be given a return authorization number and instr
5. longer cord is necessary an approved extension cord may be used The electrical rating of the extension cord must be equal to or greater than the rating of the product Care must be taken to arrange the extension cord so that it will not drape on obstacles where it can be pulled on by children or accidentally tripped over Thank you for choosing The EverFresh Air Exchange System To ensure the best performance from your new product please read these instructions completely before beginning installation and operation GENERAL INFORMATION e The EverFresh Air Exchange System is designed to fit in double hung windows only e The window opening can be between 26 inches and 38 inches wide You will need an electrical outlet within five 5 feet of the center of the window e You will need a black marker scissors a Phillios head screwdriver and a tape measure to install the unit UNPACKING 1 Carefully unpack the contents from the carton and remove the Air Exchange System from the plastic bag Egue 2 Place the Air Exchange System on a clean surface with the front grill facing down and slide the Window Sealing Frame off the back of the unit See Figure 1 3 Remove the two Plastic Extender Panels from the plastic bags and then remove the Foam Insulation Blocks from inside the Plastic Extender Panels 4 Verify that you received all of the parts shown in Figure 2 If any parts are missing please contact our consumer ser
6. provisions shall be deemed to be amended to the extent necessary to comply therewith For Warranty Service please call 1 800 253 2764 in North America KEEP THIS NUMBER FOR FUTURE REFERENCE A Bionaire consumer service representative will helo determine which is the best procedure for your Air Exchange System to be repaired If you have questions or comments feel free to write us at Consumer Service Department 13120 J urupa Avenue Fontana CA 92337 Bionaire the Bionaire logo and EverFresh are trademarks of J CS THG LLC Bionaire CS 1aG LEG Consumer Service Department 13120 J urupa Avenue Fontana CA 92337 BAP33605EM 2 9100040002234 Printed In China V J NN al S EverFresh Air Exchange System mowa BAP336 Read instructions before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on air cleaner cal 1 800 253 2764 in North America BAP33605EM2 qxd 10 14 05 9 27 AM Page 2 PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following e Read all instructions before using the appliance e To avoid fire or shock hazard plug the product directly into a 120V AC electrical outlet Remove
7. the room in square feet Measure room length and width in feet and multiply Length X Width Room Size in Sq Ft Write room size here __ lt If additional Plastic Extender Panels and Foam blocks are needed contact Consumer Service 1 800 253 2764 OPERATION OF THE EVERFRESH AIR EXCHANGE SYSTEM INSTRUCTIONS To turn on the system 1 Plug the power cord into a wall outlet 2 Turn the Damper Switch 1 to the the ON position 3 Press the Mode Button 2 Figure 17 Layout of controls and display 1 Damper Switch Opens system to the out side 2 Mode Button Turn motor on off Select motor speed N o m T a 6 Performance Bars A o 4 Display Shows motor speed number oflair exchanges day programmed room size heat 5 Service Reset balance on off and service indicator 3 Turns Heat alance on off NOTE When you use the unit for the first time there may be a Slight residual odor from the manufacturing process This will disap pear with use For best efficiency we recommend that you program your system to the size of your room 4 Refer the room measurement you made in step 22 of the Installation Instructions Your room Is Small if it is 90 159 sq ft Medium if it is 160 249 sq ft Large if it is 250 399 sq ft 5 Press and hold the Mode button 2 and the Heat Balance but ton
8. 3 for three seconds until the word small flashes 6 Release the Mode button 2 and press the Heat Balance button 3 until the desired room size is displayed The unit has three motor speeds plus OFF Normal Low Turbo OFF Press the mode button 2 repeatedly until the desired motor speed is displayed The Air Exchange System is equipped with a Heat Balance setting When this setting is on the system equalizes the outside air it draws in to the air temperature of the room To Turn on the Heat Balance setting Press the Heat Balance button 3 once
9. e black filters from Opening 5 openings 2 3 and 4 Gently wash these filters with mild soapy water Rinse in warm running water Shake off excess water and allow to air dry completely See Figure 23 7 Remove the filter from opening 1 If t is a white electrostatic filter dis card it and replace with a fresh fit ter Call 1 800 253 2764 to order replacement filters See Figure 24 Opening 1 8 If itis a black washable filter Figure 25 Clean it as described in step 6 9 Remove the rubber Vacuum Plug from opening 5 See Figure 25 10 Using a vacuum with a hose and a crevice tool GENTLY vacuum the dust from the core by accessing openings 2 and 5 See Figure 26 Figure 26 CAUTION Avoid applying pressure or scraping the surface of the core with the crevice tool as this may damage the core and decrease performance of the Air Exchange System 11 Replace the rubber Vacuum Plug in opening 5 See Figure 25 12 After the filters are completely dry replace the three black filters over openings 2 3 4 13 Insert a clean dry black filter or a new white electrostatic filter over opening 1 14 Clean the rear grill with warm soapy water Not dish washer Safe Dry with a soft cloth 15 Remove dust from the front grill with a small soft brush or cloth 16 Wipe down the rest of the unit with a clean damp cloth WARNING DO NOT IMMERSE THE AIR EXCHANGE SYSTEM IN WATER 17 Reinstall the rear
10. excess sections along the scored indications See Figure 9 Remove the same number of segments from the back of the Plastic Extender Panel 9 Repeat this process on the other Plastic Extender Panel 10 Install the Foam Insulation Blocks into the Plastic Extender Panels Note that the Foam Insulation Blocks are divided into vertical segments of various widths The foam is installed with these segments oriented vertically See Figure 10A Insert a Foam Insulation Block into the right Plastic Extender Panel For proper fit the foam should be only slightly wider than the Plastic Extender Panel If the Figure 10B 11 Remove the excess foam segments at the seam Save the extra segments They can be used to fill any gaps in the window seal 12 Repeat the process for the other Plastic Extender Panel 13 Hold the Window Sealing Frame so the rim side of the assembly is facing outside and the locking clamp is on top See Figure 11 14 Insert the right side of the Window Sealing Frame into the window frame and into the win dow track See Figure 12 15 Firmly push the left side of the Window Sealing Frame into the window frame and into the win dow track See Figure 13 Then gently press the Window Sealing Frame down so that it is seated in the window 16 Close the window Make sure the bottom edge of the window sash is resting on the foam strip sealing any gaps around the Window Sealing Frame 17 Tighten the locking sc
11. or mechani cal functions on this unit Doing so will void the warranty on serviceable parts All servicing should be performed by qualified personnel only e WARNING To reduce the risk of fire or electric shock DO NOT use this product with any solid state speed control device e Install horizontally only in a double hung window as described in this manual e All filter servicing should be performed from inside the room Outside filters should be serviced by first sliding the unit out of the Window Sealing Frame and into the room e DO NOT use unit as a shelf or place anything on top of unt PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS CONSUMER SAFETY INFORMATION THIS PRODUCT IS EQUIPPED WITH A 3 PRONG PLUG This product is for use on 120 volts The cord has a plug A as shown Use an adapter C not included for connecting three blade grounding type plugs to two slot recep tacles B The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used ee D if a three slot grounded receptacle is X R LOVER OF GROUNDED available PN ay DO NOT DEFEAT THE SAFETY ADAPTER PURPOSE OF THIS PLUG IN ANY WAY GROUNDING S MEANS CORD AND PLUG INSTALLATION SAFETY NSTRUCTIONS The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in or tripping over a longer cord If a
12. rew using a Phillips head screwdriver Be careful to not over tighten See Figure 14 18 Install the appropriate window sill J Hooks into the Window Sealing Frame See the parts list Slide the J Hook until it is firmly seated against the mold ing See Figure 15 NOTE These hooks may not fit some older window moldings 19 Install the Sash Insulation Strip as shown in Figure 16 20 Before installing the Air Exchange Unit verify that a All foam strips are in place and that there are no visible gaps b The window sash is firmly Closed against the foam strip on top of the Window Sealing Frame c The locking clamp tightly grips the window sash Figure 11 Figure 14 rd ra Window Sill Insullation d The foam blocks are tightly sealed against the window frame e If used the window sill J Hooks are secured to the window sill f Sash Insulation strip is in place g Use the extra foam strips or segments to fill in any visible gaps 21 Slide the Air Exchange Unit into the Window Sealing Frame and push until it locks clicks into place foam is the exact size rotate the foam block to utilize the half size foam block on the opposite side Reinstall the foam into the Plastic Extender Panel See Figure 10B Large Blocks 22 For maximum efficiency you will need to know the size of
13. rical or mechanical functions on this unit Doing so will void the warranty This unit contains no user serviceable parts Only qualified personnel should perform servicing other than what is described in this manual About the Filters Figure 18 There are three black washable filters installed in the Air Exchange System Each has a single tab that locks them into the unit See Figure 18 D There is one two tab filter installed in the Air Exchange System This will either be a black washable filter Figure 19 or a white disposable Electrostatic filter The Electrostatic filter removes smaller particles from the circulating air See Figure 19 PERFORMING MAINTENANCE 1 Confirm that the Service Indicator bars 6 no longer illuminate and the word SERVICE displays This Signals that maintenance is required 2 Turn off and unplug the unit 3 Remove the Air Exchange System from the Window Sealing Frame See Figure 20 Grasp each side of the Air Exchange System and gently pull it toward you Place the unit on a clean level surface 4 Remove the front grill See Figure 21 5 To remove the rear grill See Figure 22 Figure 22 e Put the unit with the face a Figure p7 down on the surface Place your thumb under the opening in the rear grill and pull up One side of the grill will lift up and you will be able to slide the grill out Figure 23 Opening 3 6 Remove th
14. uctions returning the unit from the Customer service representative WARRANTY The Manufacturer warrants to the first retail purchaser for FIVE 5 YEARS from the date of original purchase either to repair or replace at its option without charge parts and labor any supplied or man ufactured part of this Air Exchange System which upon inspection by an authorized service center proves to have failed in normal use due to defects in material or workmanship or at its option to replace the unit Operation under conditions other than those rec ommended or at voltages other than the voltage indicated on the unit or any attempts by unauthorized personnel to service the unit or modify it will render the guarantee void The Manufacturer shall not be liable for any personal injury property damage or any inci dental or consequential damages of any kind including water dam age resulting from defects malfunctions misuse improper installa tion or alteration of the product THE MANUFACTURER EXPRESSLY DISCLAIMS ALL RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES CAUSED BY USE OF THIS PRODUCT The provisions of this Warranty are in addition to and nota modification of or subtraction from the statutory warranties and other rights and remedies contained in any applicable legislation and to the extent that any such provision purports to disclaim exclude or limit any such statutory warranties or other rights or remedies such
15. vice depart ment at 1 800 253 2764 J OWD Air Exchange Unit Window Sealing Frame Left and Right Plastic Extender Panel with window width indicators Foam Insulation Blocks Figure 2 TI INSTALLATION You must install the Window Sealing Frame into the track for your lower window sash before loading the Air Exchange System into the Window Sealing Frame 1 Measure the frametrack for your lower window sash at its widest point See Figure 3 Write your measurement here ooo You may close the window temporarily 2 f your window has a screen or storm window measure the dis tance between the front of the window the side facing inside to the screen or storm window If that measurement is less than five 5 inches you will need to remove the screen or storm win dow before you can install the Window Sealing Frame 3 Place the Window Sealing Frame on a flat surface rim side up with the locking clamp away from you See Figure 4 4 Place the Plastic Extender Panel Stamped LEFT on the left side of the Window Sealing Frame and the Plastic Extender Panel Stamped RIGHT on the right side See Figure 5 5 Slide the Plastic Extender Panels down into the guides on the Sides of the Window Sealing Frame and press down gently until the Plastic Extender Panels click into place See Figure 6 E Window Sill hooks two options for best window sill fit 1 Standard Window J Hook

Download Pdf Manuals

image

Related Search

Related Contents

「データロガーKDL-01」取扱説明書 Rev.0802  OEHLBACH XXL HP  APmax™ - Innovative Systems  Les Lauréats du Programme REHA  Sun Fire X4100, X4100 M2, X4200, and X4200 M2 Servers Linux  Samsung ST93 راهنمای محصول  chapitre 4. – decouper des images depuis la  User manual  GSM Alarm System User Manual WASMS-B  Maxi-Cosi Easy Base  