Home
        GSM Alarm System User Manual WASMS-B
         Contents
1.   7 2 5 Inquiry System Status    XXXXEE     xxxx    Stands for the password  1 4 digits      Return SMS    Armed or At House or Disarmed    AC Power is Ok or AC Power is failed  GSM Value is 17 or other value  Output Relay is Closed or   Output Relay is opened       The Output relay status in the Return SMS is the independent output relay status  It is    Page 2 0 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     not the alarm link Output Relay Status     8  Installation    Before installing the control unit and sensors and sirens  please help to test the system  firstly  including wireless sensor  power supply  gsm signal  etc    Please ensure the wireless sensors and electricity appliances from the mainframe more  than 3 5m    8 1 Insert SIM into Control Unit and install the GSM ANT    In the backside of the control unit  please install the GSM SIM card          wi  v    4   The GSM ANT must be Vertical installation to ensure it in good  working condition        8 2 Install the Wireless Magnetic door window sensors  Magnetic door window sensors signal the Control Unit when the two parts  separate by more than between 1 5 to 3 0cm        Low Voltage Indicator  i Double Faced Tape    Work Indicator                In some circumstances an Infrared beam fence is more appropriate than  magnetic sensors  i e  veranda  picture window balcony  boundary wall e t c     Page 2 1 of31 Ver1 0    A Top Safety and Protection Solution Worldwide        Wireless glass break 
2.  In this status  the sensors had been set as  Stay Type triggered will alarm  but the sensors had been set as normal Type    triggered will not alarm  Please see the menu of the  Edit RF Zone     Press Emergency button  SOS     P    on the remote control or the control unit  or Press any Emergency button  The Control Unit will enter emergency  alarm  The siren will not sound  but will alert the pre set phone number  immediately   7 2 SMS Commands for Arm or Disarm or Inquiry system status or  switch on off independent output relay   The User can Arm Disarm Inquriysystem status Switch on or off the  independent output relay by sending SMS to the Control unit  The SMS  Commands are below   The system will carry out the commands immediately  with no delay  after the Control  Unit receive this SMS command   7 2 1 Armed    XXXxxXAA    Example    Return SMS       7 2 2 Disarm    Page 1 9 of31 Ver1 0    A Top Safety and Protection Solution Worldwide     XxxxBB Example       xxxx    Stands for the password 1111BB     1 4 digits    Return SMS    System deactivated     When the Password is 1111       7 2 3 Switch On the independent output relay    XxxxCC Example     xxxx    Stands for the password 1111CC   1 4 digits     Return SMS  Output Relay Closed     When the Password is 1111       7 2 4 Switch OFF the independent output relay    Example    VOO OAD D   1111DD       XXXX    Stands for the password   1 4 digits     Return SMS   Output Relay Opened     When the Password is 1111     
3.  been triggered    Equips with 16 Wireless Zones and 8 Wired zones  zone attribute   Normal At House or Stay mode  and Zone Name is editable    3 X 24 Hour zones for smoke and gas leakage sensor  1XWatchdog  zone for monitoring elder or child  1XSOS zone for emergency help   Supports 3 SMS Alert Numbers and 5 Calling alert numbers and 100  Alarm Records for owner review    Supports Timer for automatically arm or disarm the system    Supports armed delay to give enough time to you go out the home  the  delay time is editable by user    Equips with 1 Alarm Link output relay  once the system triggered  the  output will switch on for 4minutes    Equips with 1 seperate output relay  it can be switch on or off by SMS  Commands  This is very useful for remote switch on light or off while  you re in another city in the night    The Keypad can use as a dialer  the functions like the Cell phone   The external power failure  amp  recovery alert function is optional    Supports wiretap through the internal microphone    Supports internal Speaker to special user for two way voice  communication    It is Compatible with PT2262 and PT2242 wireless IC     Page 7 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     17  Standby internal rechargeable battery which can last 18 hours     18  Based on the GSM communication network and Operation Menu    Display technology  apply to wide range situations     6  Settings    1     2     3     4     5     6     7     Please insert the SI
4.  to on site inspection    2  If enable the RCO alert function  then when use any remote control which has been  registered to the system to arm or disarm or stay operation  the system will send SMS  to the first SMS number    3  If enable the GSM Jammer Alert function  when the GSM Signal is 0 for more than 90s   the system will drive the siren for 60seconds and the link output relay will close 4  minutes    6 3 Modify the SMS Alert Content of the Zone  Zone or Sensor Name    The unit accepts SMS Command to modify the SMS Alert Content of the   zone     For Wireless Zone Name  the format is   Password   M Zone Serial  Number   New Zone Name    the Max  Character for the zone name is 32     The Zone Serial Number is 01 16 corresponding to the LCD Menu and  6 2 2 1 table  If setup successful  the system will return OK to confirm the  operation     Page 1 7 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     E g   Modify the first wireless zone name as Front Door Opened by Intruder  You should    edit a SMS Content   1234 M01  Front Door Opened by Intruder    the 1234 is the    password  Then send it to the Simcard Number     For Wired Zone Name  the format is   Password   Z Zone Serial  Number   New Zone Name    the Max  Character for the zone name is 32     The Zone Serial Number is 01 08 corresponding to the LCD Menu and  6 2 2 2 table  If setup successful  the system will return OK to confirm the  operation    E g   Modify the first wired zone name as Front Do
5. 1234        Page 1 0 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     6 2 1 View       To check the alarm records  up to 100 event  records will be saved       To check the Timer you have setup       To check the SMS Alert Contents of the  Wireless Related Zones       To check the SMS Alert Numbers      To check the Auto dial teleohone Numbers      To check the report time        To check the RF sensor wireless code        To check the SMS Alert Contents of the Wired  Related Zones        1  The RF Code Query function is for check the wireless sensor transmission  You can  enter this submenu  then triggered the wireless sensor  if in the LCD can display some    codes  means the wireless sensor can transmit wireless signal     6 2 2 Setup       To add or remove wireless sensors or remote  controls and edit their attributes        To setup Wired Zone parameters of the system      To setup basic parameters of the system        To setup the advanced parameters of the       Page 1 1 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     6 2 2 1 Add Del RF Parts      To setup the zone   s attribute and add new  wireless sensors to specificities zone      To add new remote controls      To remove all registered wireless sensors and  remote controls     1  Zones    Attribute definition     and not alarm in disarmed mode   sensors with Normal type triggered will not alarm     In the starting time point and ending time point  the sensors with  Watchdog thi
6. MCard firstly  and install the GSM Antenna then power on it  Also   you can insert the SIMCard after you setup    All the wireless sensors in the standard package we have assigned to the mainframe  already  Neednt to learn it again    After you power on the mainframe  the mainframe will auto detect and display the  process  It will detect the 8 wired input current connection status and display on the  LCD with 8 characters   O stands for Open   C stands for Close   L stands for with2 2K  EOL   E Stands for not includes the before 3 status  If it with SIMCard  it will register  the GSM Network and display the GSM Signal ICON in the left corner of the LCD    All of the setup can be done by the LCD except modify the Zone name  if you need to  modify the zone name  please see the command list in the related chapter    Only disarm by keyboard and modify settings requires password  the other operation  needn t password  The default password is 1234  Enter password then press Enter  button to enter the system    In standby mode  press  3 6  following UP button  The system will recovery to  factory default settings  the password will be 1234  But the registered wireless  sensors and the Wired type will remain    Two way communication     In standby mode  dial the teleohone number  following the t  the system will dial    out  While incoming call  press the   4 Button to answer the incoming  Please    note  if the income calling is from the preset number  Includes SMS Alert number  an
7. Optional Accessories   Wireless Sensors or Wired Sensors    PIR Motion Sensor  Glass Break Sensor  Magnetic Window Sensor   Magnetic Steel Scrolling Door Sensor  Temperature Sensor  Photoelectric  Beams  etc     4  Physical Layout  4 1 Control Unit physical layout    1     2     In order to forbidden the intruder power off the alarm system  we equipped the power  switch inside  it is nearby the SIMCard socket  please pay attention to it  and don t tell  others of this  Turn it towards inside is off  turn it towards outside is on    We reserved the plastics of the output relay and Wired sensors in the back cover of  the panel  Because of some of the users needn t this function  If you want to use the  output relay and wired sensors  please remove the plastics carefully  Then you can  see the connectors inside     Page 3 of31 Ver1 0    A Top Safety and Protection Solution Worldwide     O O    Power Siren    OOO  000 Mircophone  Interface 1 Description  External Power Connector  Connect to 2A 12V DC power  through AC DC Adaptor  Hep  Will start for 60seconds when alarm  The siren or strobe  siren should be  lt 12V DC  Hep    GSM ANT   Connect the GSM ANT  if the GSM signal is not strong   then please change the 3dB GSM ANT       Microphone   One sensitive Microphone built inside           Interface 2 Description     12V IN1 GND IN2 IN3 GND IN4 IN5 GND ING IN7 GND IN8  12V R1  R1  R2  R2      12VDC 1A power output for wired detectors     Digital input 1  connect to one wire of th
8. When AC power failure  the  12VDC point will no power    supply     NC Type Connection     12V IN1 GND IN2 IN3 GND IN4 IN5 GND IN6 IN7 GND IN8  12V R1  R1  R2  R2           til    n  i          1  The two  12V are power    z source for wired sensors  2 P    2  The R1  R1  is the alarm    F p  P     link output relay  id is  A 3  The R2  R2  is a seperate AE font  output relay  which can be ead iena  NC Type Sensors switched ON OFF by SMS  Commands  ea      4  The no use inputs must be keep in short circuited by wires     Page 2 4 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     EOL Type Connections     12V IN1 GND IN2 IN3 GND IN4 IN5 GND IN6 IN7 GND IN8  12V R1  R1  R2  R2         1 The no use inputs must be shorted by a 2 2K resistor   2 The Detector must by NC type   2 2K   mg 3 We suggest connect the 2 2K Resistor inside the  l detector box in series connection     NC Type Sensors    NO Type Connection     12V IN1 GND IN2 IN3 GND IN4 IN5 GND IN6 IN7 GND INg  12V R1  R1  R2  R2            1  We re strongly suggest not use this connection type   2  In this connection type  all of the wired sensors must be NO   and the no use inputs must be free  can not be in short circuited  mode     NO Type Sensor    A    8 5 Install the Control Unit   In order to avoid destruction of the Control Unit by intruders  please install it   in a concealed location  convenient to the operator    If applicable  ensure that an uninterruptible AC power outlet is available   near t
9. a  taf    LD    A New User Friendly Concept GSM Alarm System For Your Assets     3       GSM Alarm System  User Manual WASMS B  Ver 1 20 Date Issued  2010 09 14    All rights reserved by Wireless Alarm    Website  Http   www securitywireless co za  Ver 1 00 Date Issued  2010 09 01    A a oS YS p    10   LI   12   13   14     A Top Safety and Protection Solution Worldwide     Table of Contents    Brief introduction                                     2  Safety Directions                                      2  Standard Packing list                                3  Physical Layout                                       3  Features                       22 22 22 22 222 2n nn nnn nnn nne 6   Settings                0 222m 8   Operating Instructions                            18  Installation                                             21  Add wireless sensors                              26  Technical specifications                          28  Important information                             29  Maintenance                                          29  Quality Warranty                                     29  Trouble Shooting Guide                          30    Page 1 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     1  Brief introduction    The GSM Alarm System is a new security protection solution special for  home  house and office and other applications  It based on Wireless GSM  Communication network  integrated Lcd Menu display and Computer  technology  W
10. ber can call in the   if nobody answer the  calling  then can not wiretap the system site  if somebody answers the calling  then    can create two way voice communication     Page 1 5 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide   For example   In China  the country code is 0086   please note  do not write  86     The user cell phone number is  13570810254 and has been assigned as a SMS Alert  number  the simcard number in the panel is  13512345678     Problem 1  Alarm but the user hasn   t received the SMS Alert     Solution  Please plus the country code while you setup the 13570810254 as SMS    Alert number  means setup 008613570810254 to instead of the 13570810254      Problem 2  The user number can receive the SMS Alert message from alarm panel   but the alarm panel can not receive the commands from the user number     Solution  Please add country code to the simcard number in the alarm panel  Means    send sms commands to  008613512345678  to instead of 13512345678     Solution 3  When you use cell phone dial another one  what number it will be  displayed then you can set the displayed number as dial numbers  when you use cell  phone send SMS to another cell phone  what number it will be displayed then you can    ft 7    set the displayed number as SMS Alert number  just use the 00 to replace the                3  If Switch off the siren  then all alarm raised will not drive the siren  if switch on the siren   then when the system alarm will drive the s
11. d Auto dial numbers   then before 6 tones  if answered it  will create two way  voice communications  After 6 tones  will be entering into wiretap status  The user  can listen in the alarm around sounds  Max  time is 10Minutes  If the income calling  is not from the preset alarm number  after 6 tones  if hasn   t been answered  will    hang up     Page 8 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     8  Ifyou want to test the two way voice communication  please make sure the other  phone is far from the   at least 500meters  Otherwise  the near cross will make lots  of noise interference    9  Please setup at least one alarm alert number  otherwise the mainframe will only  activate the siren to work 6 times  this is to remind you setup alarm numbers    6 1 Key Function Descriptions     TA          JEBE  JHLE  JANE    a  i  7 E  GSM Alarm System          _    5  E  D     gt  atmo  t  A  a o li     6 1 1 Led indicator Description   The unit uses the icons to stand for the function  it is visual and intuitive to users       A    _ Arm Mode indicator  on is in arm mode  off is in disarm mode     Stay Mode indicator  on is in stay mode     A Alarm Indicator  on is alarming  off is normally     le GSM Module indicator  registering will quickly flick  registered successful    will slowly flick     TY Q l Alarm link output indicator  when alarm  will turn on and last 4minutes     means the alarm link output relay closing   Separate output relay indicator  when th
12. e Control Unit can run and sensors work  but cannot send SMS texts   please change SIM Card to check it    4  If the problem cannot be solved  please contact the distributor     13  Warranty    1  This system is warranted to be free of defects in material and  workmanship for one year from the date of purchase    2  This warranty does not extend to any defect  malfunction or failure  caused by abuse or misuse by the Operating Instructions     14  Trouble Shooting Guide    PROBLEM CAUSE POSSIBLE SOLUTION  GSM Module     Backup battery with low   1  Please contact the AC Power   initialization voltage GSM Module 2  Please help to take the panel to a mobile  failed connection loose in phone repairmen store  and then ask the  transportation  engineer to check the GSM Module    GSM Signal is too socket and the GSM Module connection   weak  3  Please change another position to install  the alarm panel     Automatically   1  Backup battery with 1  When the backup battery voltage is lower  Restart low voltage  than 3 7V  the panel will alert by buzzer    sounds  Please help to contact the AC  Power     Wireless 1  Wireless sensor with   1  Please replace the battery of the wireless       Sensor low voltage  sensor  usually once  year     Page 2 9 of31 Ver1 0    transmission    short    False Alarm    Alarm without  SMS    Alarm without  Dial    No action  after send  SMS    command    A Top Safety and Protection Solution Worldwide     2  Wireless sensor used  PT2262 IC  and  incorrec
13. e independent output relay closed   w gt  p p y p p y    it will be on  when the independent output relay opened  will be off   6 1 2 LCD ICONS Description    Page 9 of31 Ver 1 0    A Top Safety and Protection Solution Worldwide     The unit uses the icons to descript the present status  it will be more user friendly       Enabled the Timer to arm and disarm function  otherwise  will not display it     Timer to Arm  has setup a time point to enter armed mode directly       Timer to disarm  Has setup a time point to enter disarmed mode directly   Enabled the Watchdog zone  In the fixed time range if the sensors in the      watchdog zone hasn t been triggered  will alarm     Enabled the system condition report function  Will automatically send system    condition to the user by SMS  otherwise  it will not display     6 1 3 Keyboard functions       The unit uses the icons to mark the buttons  it will be more user friendly to user      7  Enter button  dial out and answer incoming     7s  Hang up the incoming  Exit  and Backspace button   cy   Up towards button        Down towards button      a  Turn Left button  in special menu need it to choose the option       a Disarm Button    E     fa Arm Button         Es  At House  Stay mode button     A SOS  Panic Button     6 2 Main Menu    In standby mode  press the  7 button  you can see the Menu       To check the settings and event records of the  system     To setup the system functions  requires password   the default password is 
14. e wired Detector     Ground point  connect to another wire of the wired Detector or   12VDC     Digital input 2  connect to one wire of the wired Detector     INS Digital input 3  connect to one wire of the wired Detector        Page 4 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     Ground point  connect to another wire of the wired Detector    Digital input 4  connect to one wire of the wired Detector    Digital input 5  connect to one wire of the wired Detector    Ground point  connect to another wire of the wired Detector    Digital input7  connect to another wire of the wired Detector    Ground point  connect to another wire of the wired Detector or    12VDC   Digital input 8  connect to one wire of the wired Detector    12VDC 1A power output for wired detectors     Link Output Relay  when the system alarm will close 4minutes     ING Digital input 6  connect to one wire of the wired Detector  ros     Rated Voltage  3A 240VAC   this relay can connect to any other  lights or CCTV system as a switch     Built in 240VAC 3A rated relay output  connect to the device  negative electrode     Commands   Rated Voltage  3A 240VAC   this relay is very    useful to switch on light when you can not come back in the    evening  Then some hours you can switch off it     Built in 240VAC 3A rated relay output  connect to the device  negative electrode     4 2 Working Principle Drawing  The unit works with wireless detectors or Wired detectors  It can switch on  or off o
15. ess button    c  then following the instruction   1 Turn On the Device   means trigger the  Remote Control  the system will show a code  then on    the Keyboard  The system will ask you repeat the operation  so please  trigger Remote Control again  when you see the Code  then press the  Enter Button on the Keyboard  the system will display  Saved OK  It  means the Remote Control added to the system  Repeat this operation  to add other remote controls    1  VVVV means this serial position saved one remote control already  you can learn a   new remote control to replace it    9 4 Delete all wireless sensors and remote controls    Go back to the menu  then select the Remove All  select it then the system   will alert Are You Sure  gt  Press Enter to remove all the RF Parts of the   system     10  Technical specifications of Control Unit    Page 2 7 of31 Ver1 0    A Top Safety and Protection Solution Worldwide     Rated Voltage  9 12VDC 2A Standby current  30 40mA  Siren Output Voltage  12VDC  Working temperature   10  C   60   C  Storage temperature  20  C   60  C  Relative humidity  10 90   No condensation  Work frequency  900 1800 MHz or 850 900 1800 1 900MHz  Communication protocol  GSM PHASE 2 2   include data service   Wireless sensor receiving frequency  433 MHz  Wireless sensor permission quantity  16Pcs  Wired Zones  Remote Control permission quantity  8Pcs 5Pcs  Effective distance wireless of remote control  50 m sight line  Battery  Built in lithium ion battery  1200mA
16. f 31 Ver1 0    A Top Safety and Protection Solution Worldwide     as Normal triggered will not alarm  the sensor set as Stay triggered will Alarm  If the  system is under Armed Mode  then all RF sensors triggered  will alarm  This is very  important to remember the sensor types of the system  This function is very useful  when you at house and need some sensors in working status  E g   the sensor  installed outer and gas and smoke detectors  etc   and some sensors indoor not in  working status  e g   the sensors installed in the living room  bed room  etc      4  The unit can accept total 16 wireless sensors to 16 wireless zones  each zone can be  assigned one wireless sensor  and renamed it by SMS Command  And 5 remote  controls    Wireless Zone Serial Number  Default Zone Name and Zone Attributes Table     eT ee  PGT nrsion from Enny Door  Normal  P96 irsin from Front Balcony  Normal  P08   tnrusion rom 1F Window   Nomal  09 inrasion rom 2F Window   Noma  24 Hour zones  This attribute can  A  zones triggered will alarm     Watchdog Zone  the attribute can  not be modified  In arm or disarm or  stay mode  once the sensor in this   Watchdog alarm zone triggered in the preset time   will not alarm  if the sensor hasn   t  been triggered in the preset time   will alarm     SOS zone  The attribute can not be  16 SOS Help  modified  In arm or disarm or stay  mode  once the sensor in these    Page 1 3 of 31 Ver1 0       A Top Safety and Protection Solution Worldwide     zones trig
17. gered will alarm  immediately  not drive the siren     Notice  The Additional Panic Button  and the SOS button on the Keyboard and    remote control is the same attribute with the SOS zone  If the Additional Panic  Button assigned in 24 Hour Zones  once triggered  the alarm action will be the  same as SOS zone  not start the siren        6 2 2 2 Wired Zones Set      To setup the wired inputs type       To setup the wired input   s attribute        1  The Nodes Type NC NO EOL should reference the wired input sensor type  The  Default is NC and we short all of the inputs by wires  if you want to contact wired  sensors  then please replace the short wires by wired sensors directly  The no use    input  please remain them in short circuited by wires  Please see 8 4 Install the  Wired Sensors and Electricity equipments  2  Zones    Attribute definition of the wired zone is the same as the wireless zone     3  The unit can accept total 8 wired sensors to 8 wired zones  each zone can be  assigned one wired sensor  and renamed it by SMS Command   4  Wired Zone Serial Number  Default Zone Name and Zone Attributes Table     Zone SN  Default Zone Name   Default Zone Attribute    24 Hour zones  This attribute can not    24Hours zone alarm be modified  In arm or disarm or stay    24Hours zone alarm triggered will alarm immediately     SOS zone  The attribute can not be  modified  In arm or disarm or stay   SOS Help  mode  once the sensor in these zones  triggered will alarm immediately  B
18. h 3 7V   Standby time Approx 8 hours  depending on the network condition   Size  180mmX125mmxX30mm  LXWXH   Net Weight  0 36Kg    11  Important information    1  The Control unit will auto switch off when the backup battery voltage  less than 3 7V  before switching off  it will drive the buzzer to alert you by  sounds    2  Please read the User Manual carefully before you install the Control Unit  and set the Control Unit    3  The siren and relays will not work if the AC DC power goes off   because of both of them are working at 12V voltage    4  Do not install the system in close vicinity with objects that generate  strong interference  such as TV set and computer     5  Install the system in a hidden place    6  Avoid getting water into the Control Unit    7  Have a secure connection to the main power supply    8  This product was designed for the indoor use    9  More information will be available of the   we will not inform you again    after we upgraded  please check with your dealers     Page 2 8 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     12  Maintenance    1  If the Control Unit works  while the remote control and other sensors fail   please check and change the battery    2  If the remote control works  but the Control Unit fails to send SMS texts   switch the power of Control Unit off and switch it on after one minute    Test this system after another minute  or check the settings are correct  and the GSM Signals are strong enough    3  If th
19. he Control Unit  First connect accessories to the Control Unit then the  AC adapter    8 6 Install Siren   Connecting the Siren to the Control Unit and fix them in appropriate locations   The Siren should be at least 1 5meters away from the GSM SMS Controller unit  if possible     more than 3meters is better     9  Add Wireless Sensors to the Control Unit    Page 2 5 of31 Ver1 0    A Top Safety and Protection Solution Worldwide     1  Some wireless sensors must be coded by manual as below 9 1 step  some wireless  sensors needn t coded by manual  because of we will use the learning code sensor   The learning code wireless sensor you can omit the 9 1 step  can be learned to the  system directly  like the PIR 100B and DM 100A    2  Please remember setup the PIR 100B to Test Mode while learning to the host  after  assigned to the mainframe  then please setup to USER Mode by change the Black  PIN Jumpers in the PIR 100B  please see the PIR 100B user manual    The Wireless sensors in the package box are pre coded prior to shipping    The Max  Quantity of RF sensors is 16  if you need add more then you can   set the wireless sensor with the same jumper  Add additional wireless   sensors to the control units  please help to see below    9 1 Prepare the RF Sensors of PT2262 IC Code   1  Prepare the RF sensors  Open the back cover of the Wireless sensor  carefully    2  Locate the IC boards black jumpers  labeled AO A7 and DO D3    3  Configured the AO A7 and DO D8 different from each 
20. hen any sensor activated  it will Call  amp  Send SMS to  owner s telephone immediately     The GSM Alarm System with user friendly design idea  all operations and  settings are visual and intuitive      What you need is a SIMCard which supports Call ID function     2 Safety Directions       N  A       D       Safe Startup  Do not use GSM Alarm System when using GSM equipment  is prohibited or might bring disturbance or danger     Interference  All wireless equipment might interfere network signals of GSM  Alarm System and influences its performance     Avoid Use at Gas Station  Do not use GSM Alarm System at a gas station  Power off  GSM Alarm System it near fuels or chemicals     Power it off near Blasting Places  Please follow relevant restrictive regulations  Avoid using the  device in blasting places     Reasonable Use  Please install the product at suitable places as described in the    product documentation  Avoid signal screening by covering the    Page 2 of31 Ver1 0       A Top Safety and Protection Solution Worldwide     mainframe   Use Qualified Maintenance Service  Maintenance can be carried out only by qualified maintainer     Waterproofness    The product is not waterproof  Please install it at dry places  and keep it dry     3  Standard Packing List    Control Unit X1   Wireless Magnetic Door Sensor X1  Wireless Remote Controls X 2  Wireless PIR Motion Sensor X1  Wired Strobe Siren  110dB  X1  Regulated 12VDC Power Supply X1  User Manual X1   GSM Antenna X1    
21. iren for 1 minute except the SOS helo  caused  Default is Switch on    4  If setup the Report Time Gap  the system will periodically send    GSM Alarm System in  good working condition    to the first SMS Alert number  This is very useful for long time  use the system  Default is 0  Means will not report the system condition    5  If enable the power failure alert function  the system will send SMS    AC Power Failed  30Min     to the first SMS Alert numbers after the AC power failure 30minutes  if the  power is recovery then will send SMS    AC Power is OK      Default is disabled    6  There   s no delay for Stay Mode     6 2 2 4 Advanced Setting    Page 16 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide       To setup the starting time to arm and the Ending  time to disarm     To setup the starting and ending time to work       To setup the remote control operation report  function     To setup the GSM Jammer Alert function       Modify the system password      Restore the system settings to factory defaults     All of the remote controls and wireless sensors  should be re assigned again        1  The watchdog is special for elder or child or on duty personnel  in the period  Starting    time point to Ending time point  if this sensor hasn   t been triggered  the system will  alarm  This is very useful to monitor the elder or child goes out the bedroom or enters  the kitchen to eat something  Or monitor the on duty personnel in the polling period  have gone
22. ne appliance by SMS command  Please see below        Independent Output Relay  Can switch on or off by SMS  R2     Page 5 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     Wired or Wirel  a  Wired or Wireless  _____     Smoke Detector    C  Fire Detector           Antenna    SMS Control Light    5  Features  5 1 The advantages of the GSM Alarm System    1  Two way Voice communication or wiretap are available        2  LCD displays the entire setup menu   3  Armed  Partial Armed At House or Stay   Disarmed  SOS are available   4  Armed delay  alarm delay  siren work or not  more other functions are    Programmable by user    5  Watchdog 24Hours Zone  SOS zone are available    6  Using ICON to display armed  Partial Armed  Disarmed  Power status   Siren status and GSM Signal status    7  Auto detect and report  GSM Signal Jammer alarm  SMS Switch is  available     8  User friendly Icons for LED indicators  LCD and functional Buttons     Page 6 of 31 Ver 1 0    A Top Safety and Protection Solution Worldwide     5 2 Functions  amp  Features of the GSM Alarm System    1     2     16     GSM Frequency  Dual Band 900 1800MHz   Quad Band is  optional 850 900 1800 1900Mhz      Supports armed  Partial armed At House or Stay  or disarmed  SOS  by remote control or mainframe keyboard    Supports armed  disarmed  inquiry mainframe status  switch on or off  relay output by SMS Commands    Automatically send SMS Alert and dial to the pre set cell phone when  any sensor had
23. or Opened by Intruder  You should    edit a SMS Content   1234 Z01  Front Door Opened by Intruder    the 1234 is the    password  Then send it to the Simcard Number     7  Operating Instructions    The user can arm disarm Stay  Partial armed  by Remote controls  Keyboard  SMS  also   the user can cancel the alarm by Remote Controls  Keyboard  SMS to Disarm it  Another   the user can switch on or off the independent output relay by SMS Commands    7 1 Arm or Disarm or Stay  Partial Arm  At House Arm  and Emergency  Alarm by remote controls       Press the button    i    on the remote control or Press Arm button on the  keyboard then select Arm  the Control Unit enters arm status  delay time  according to the setting   the im ICON will be on  Under this status  any  sensor triggered  the control unit will alarm  if answered the call  the siren  will stop and can listen in the alarm area by phone     Page 1 8 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     Press the button    ml    on the remote control  or press Disarm button on the  Keyboard then input the password  the Control Unit disarms immediately   The fi ICON will be off  Under this status  any sensor triggered  the control  unit will not alarm  Except the sensor type is the 24 Hour Zones or  Watchdog zone or SOS zone    Press the button    f    on the remote control or Press the Arm button on the  keyboard then select Stay  the Control Unit enters Stay Partial Armed   status  the f   ICON will be on 
24. s type triggered will not alarm  if the sensor hasn   t been    triggered  will make alarm     In any mode  the sensors with this type triggered will alarm but  j  SOS Help  not drive the siren     Alarm Action  when Alarm occurrence  the system will Automatically dial the Pre set  Auto Dial Tel  Numbers for 3 times one by one  and Send SMS to the Pre set SMS Alert  Numbers  in the meantime  will drive the siren for 60seconds and close the link Outout       relay for 4 minutes   2  After you enter the menu  the attribute of the zone will be displayed in the LCD  if    this zone has been assigned wireless sensor  will display    V     If hasn   t been  assigned wireless sensor  means this zone is empty  you can assign new wireless  sensor to this zone  Press Up or down button on the keyboard to check the other  Zones  Press Enter to edit it  After you pressed the Enter button  you can select the  zone attribute  and then press Enter  you can see    Turn on the device    or    Please  trigger the new wireless sensor     Then following the instruction to add the new  wireless sensor to the   For Remote control  it will display VVVV if the unit has been  assigned remote control  Both of them you can press Enter to re assign new  wireless sensor or remote control to replace the existence one    3  Inthe Edit RF Parts you can edit the attribute of the sensor as Normal or Stay Type  If  the system is under Stay Mode  Also said At House or Partial Armed   the sensor set    Page 1 2 o
25. sensor can also be used  see below     For a Scrolling Steel Door  a special Wireless Scroll Steel Door magnetic  sensor must be used due to interference of the wireless signal caused by  the steel door    Installation  attach the larger half to the floor and attach  rivet or glue  the  smaller half to the scroll steel door  An alarm is triggered when the halves  are separated by more than three to 5 00 cm       y   Qo Rivet it on the floor     A            Rivet or stick     it on the scroll E    4 steel door     A  g A  D  D     vy     eee Lue  OV bpeeaenreeLareeenewee     MAUL UL ens       Wireless Signal Transmitter       scroll Steel Door  8 3 Install the wireless PIR Motion Sensor  The PIR sensor will detect a person since human temperature is different to  ambient temperature  When triggered  the PIR will signal the Control Unit   Apply the detection area illustration below when installing     Page 2 2 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     Z  40 degree    Wireless PIR motion sensor       50 degree    Surveillance Area    2 1m       5 9m    sensor windonus          infrared       5m 10m    infrared    Wireless curtain sensor  detection area illustration below     p D       8 4 Install the Wired Sensors and Electricity equipments    Please help to see below wiring diagram  then fixed the related wired  sensors  the sensors connect to the related digital inputs     1  Please setup the NC  NO  EOL type in the PC Programmer correctly    2  If yo
26. t Value    3  Haven t pull out  wireless antenna    4  Electromagnetic  interference    5  The wireless receiver  in the panel with  problem    PIR Motion sensor  installation incorrect   Used 24H zones or  SOS Zones or    Watchdog zone   NC NO EOL is    incorrect     GSM Operator  communication  protocol    Haven t setup SMS  Alert Auto dial  Numbers    Caps Lock letters in  the SMS Commands     Please correct the resistor value to 3 3M  Ohm of the PT2262 Wireless sensor   Please pull out the wireless sensor  antenna    Please install the wireless sensors or  alarm panel away the electric  equipments    Please contact your distributors or    manufacturer to replace it     Please see the PIR Motion sensor  installation user manual carefully   Please check if any sensor assigned to  these special zones and made incorrect  activated    Please check the detector NC NO type  and NC NO EOL Correctly  and you re  sure connect a 2 2K Resistor in series in  the un use input ports    Please setup the SMS Alert Numbers   Please help to see Page 15  the sample  of setup the telephone numbers    Please check the commands with CAPS  LOCK and correct format    Also  please help to change another  GSM Operator SIMCard to test it        The End     Any questions do contact us     Tel   27 12 654 6209    Page 3 0 of 31    Ver 1 0    
27. u setup the Nodes type as NC Default  the no use inputs must be with  Short circuited by wires  and the sensor type must be NC  Please see below diagram    3  If you setup the input type as EOL  then please contact a 2 2K Resistor in series with  every inputs  if you don   t connect the sensor to the inputs  please connect a 2 2K    Page 2 3 of31 Ver1 0    4     5     6     7     8     A Top Safety and Protection Solution Worldwide     Resistor in series to instead of it  Moreover  only the digital detector is NC type can  use in EOL mode  Please see the below diagram    If you setup the input type as NO  then please keep the two points of the inputs by  free   and the sensor type must be NO  Please see the below diagram    The Unit built in 240VAC 3A rated relay  Please make sure the power cord rated  while you connect to equipment device  also  please make sure the power  consumption is less than 250W for long time working  If you need heavy equipment   please connect an additional relay     The R1  and R1  is for alarm link output  when the system alarm  will close for 4  minutes  the rated output power is 700W  If you need heavily equipment  please  connect an additional relay     The R2  and R2  is the relay output for SMS Command  CC is close  DD is open  EE  is inquiry the status    The  12VDC is for the Detectors  if the detectors need 12VDC power  then please  contact it to the  12VDC  The 12VDC power is from external power  not from backup  battery  So please note  
28. ut  not drive the siren        mode  once the sensor in these zones    Page 1 4 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     6 2 2 3 Basic Setting      To setup the SMS Alert Number  must be cell  phone numbers  total 3      To setup the Auto dial telephone number  total  is 5      To setup the time and date information  The  Format is Month Date Year  Press Up Down to  setup each item  press   to move to next item      Switch on or off the siren when Alarm  occurrence      Setup the Report time gap  Range   0 240Hours deflaut is 0  will not report      Enable or Disable the alert function while the AC  power is failure more than 30 minutes      Setup the delay time after armed the system by  remote control or keyboard  Optional  0S  20S   30S  60S  90S  Default is 30S      Setup the delay time after any sensor triggered   Optional  0S  20S  30S  60S  90S  Default is    wa    1  The SMS Alert number is for receiving the alarm SMS Message  The Auto Dial       Telephone number is for receiving the calling  Please help to try adding country code  or removing country code when you can not receive the call or SMS  Because of  different GSM Operator with different communication protocols  Our system is with the  international communications protocols    2  The Auto dial Tel  Number can dial to the   6 tones later  can wiretap the system site   Before 6 tones  if somebody answers the calling  then can create two way voice  communication  The other teleohone num
29. wireless  sensors Includes wireless door sensor  wireless smoke sensor  wireless  gas leakage sensor  wireless pir motion sensor and so on   If configured  the AO A  and D0O D3 are the same  the system will treat them as the  same one sensor    4  Also  please check the Resistors value is 3 3M Ohm  there   re 3 Jumpers   1 5M 3 3M  and 4 7M  if you select incorrect value  the wireless distance  usually very short or can not learn to the alarm panel        Page 2 6 of 31 Ver1 0    A Top Safety and Protection Solution Worldwide     Select the Zone number  press Ok  finished it then press OK to select the    Normal Type Or Stay Type  then following the instruction   1 Turn On the    Devicel  means trigger the RF sensor  the system will show a code  then   on the Keyboard  The system will ask you repeat the   operation  so please trigger RF sensor again  when you see the Code  then   press the Enter Button on the Keyboard  the system will display  Saved OK     lt means the wireless sensor added to the system  Repeat this operation to   add other wireless sensors    a  One time can add only 1 wireless sensor    b  The Name of the RF sensor can be modified by SMS commands  Please see 6 3    9 3 Add Remote Controls to the Control unit    Because of both of the unit and its remote controls are with learning code    you can add the remote control to the unit directly following the 6 2 2 1   Add Del RF Parts   a  Enter the Add Del RF Parts menu    b  Select 2  Edit Remote Ctrl  then pr
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Targus AWV1252US screen protector  L`intervention brève en dépendance dans les salles d`urgence    Boletín 161 Variador de Velocidad  Production Management Module User Manual  Modelo 34788  T'nB PVF4 wire connector      DS 3800 (36.3 cm3) - DS 4200 (40.2 cm3)    Copyright © All rights reserved. 
   Failed to retrieve file