Home

Avaya 4600 Series IP Telephones User's Manual

image

Contents

1. Port is detecting power the PD requesting power Once the PD is detected the status will change to Delivering Power Delivering Power Port is supplying requested power to device Disabled port power state is disabled Invalid PD Port is detecting device that is not a valid power device to request power Deny low priority power is disabled from port because of port setting and demands on power budget available DTE power exceeded Overload Power is disabled from port because port overloaded e Test port is in testing mode which is set using SNMP e Error None of the other conditions apply Limit Watt Sets the maximum amount of power supplied to that port The range is 3W to 20W The default value is 16 Watts which is enough to power a class 3 device 15 4 Watts as defined in the Power over Ethernet specification IEEE 802 3af 2003 e Table 2 shows the required power allocations defined by IEEE 802 3af 2003 based on the class a 15 4 Table 2 IEEE 802 3af 2003 Power Classes Priority Priority is used to determine which port s will be shut down when the total power of the switch exceeds the power budget for that switch or available DTE power The lower priority ports are shut down in favor of higher priority ports The range is low high and critical The default value is low for all ports Note When two ports have the same priority and one must be shut down the port with the higher port numb
2. AVAYA Avaya Solution amp Interoperability Test Lab Connecting Avaya 4600 Series IP Telephones and Avaya Wireless LAN Access Points with the Nortel BayStack 460 24T PWR Switch Issue 1 0 Abstract These Application Notes describe how to connect and configure Avaya 4600 Series IP Telephones and Avaya wireless LAN access points with the Nortel BayStack 460 24T PWR switch The various Avaya powering arrangements and the administration commands for displaying and controlling the powering status of the switch ports are also described SZ Reviewed Solution amp Interoperability Test Lab Application Notes 1 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc 1 Introduction Inline power is a feature offered on some Ethernet switches It is a means by which the switch can supply power to a network device within the same cable that carries the Ethernet signaling This simplifies network installation and powering design removing the need for a separate power supply for each IP telephone in the network IEEE 802 3af 2003 defines a standard protocol to be used by powering and powered devices The Nortel BayStack 460 24T PWR is a 24 port Ethernet switch It is IEEE 802 3af 2003 standards compliant and can provide power to all 24 ports With its auto discovery feature the switch automatically recognizes the connection of a powered device and immediately sends power to it These Application Notes show ho
3. gt Power Management gt Port Property NETWORKS Port Power Setting meee Port Admin Status Current Status Limit Wat Priority Volt Current mA Power Watt gt Shey Disabled Disable E High 0 0 0 0 000 SMMP Trap a a iac address Tabie 2 Enabled Delivering Power 16 High 46 9 93 4 569 Find MAC Address J Enabled Delivering Power 16 High 493 6a 3 176 Port Management High Speed Flow Control 4 Enabled Detecting E Low 7 0 0 0 0 000 a Software Download amp Configuration File 5 Enabled Detecting fe Low 0 0 O 0 000 consolelcomm Por E Enabled Detecting E Low 0 0 T 0 000 Stack Operational Mode Global F Mgnt arial gin Enabled Detecting fie Low oO o 0 000 gt Fault g Enabled Detecting E Low 0 0 0 0 000 gt Statistics 10 Enabled Detecting E Low 0 0 0 0 000 11 Enabled Detecting fie Low 0 0 O 0 000 Figure 10 Disabling Power for Port 1 Note that Figure 10 shows that port 1 current status is changed to Disable and all three power related parameters Volt Current and Power are displayed as 0 The IP telephone in port 1 lost power Enabling Power on a Port To enable power on a port e Inthe Admin Status column use the drop down arrow to select Enabled for that port e Click Submit at bottom of the page SZ Reviewed Solution amp Interoperability Test Lab Application Notes 14 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Co
4. 0 0 000 Low 0 0 0 000 2 3 Find MAC Address f Port Management 5 Enabled Detecting o0 0 000 0 0 0 000 8 g a Enabled Detecting 0 0 0 D 0 0 0 0 D D 0 0 0 0 0 i 0 0 0 0 0 0 0 Enabled Detecting Enabled Detecting Enabled vY Detecting 4 Enabled Detecting High Speed Flow Control Software Download Configuration File Console Comm Part Stack Operational Mode 0 0 0 000 VY Power Management k i Global Power Mgmt 0 0 0 000 Port Property 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 Enabled Detecting Enabled Detecting 1 Enabled v Detecting Enabled Detecting UARRA Enabled Detecting Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting Enabled Detecting Enabled Detecting Enabled v Detecting Enabled Detecting Enabled Detecting Switch Enabled I Enabled fe Enabled fe Enabled z fe Enabled z fe Enabled fe Enabled fe Enabled fe Enabled fe Enabled z fe Enabled z fe Enabled fe Enabled fe Enabled fe Low Enabled z fe Enabled z fe Enabled fe Enabled fe Enabled fe Enabled fe Enabled fe Ena
5. menu choose Configuration gt Power Management gt Port Property The port property page opens as shown in Figure 7 A BayStack 460 24T PWR Switch 169 254 100 100 Microsoft Internet Explorer File Edit View Favorites Tools Help Back gt A Asearch Favorites CBristory B Sp O S Address http 169 254 100 100 v G0 Links NORTEL RTE Configuration gt Power Management gt Port Property NETWORKS Port Power Setting a a Current mA Power Watt Enabled 7 Detecting low OO o 0 000 Low 0 0 0 000 Low 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 Remote Access SNMPv1 gt SNMPy3 SNMP Trap MAC Address Table Find MAC Address Port Management High Speed Flow Control Software Download Configuration File Console Comm Port Stack Operational Mode V Power Management Global Power Mgmt Port Property 4 Enabled Y Detecting Enabled Detecting m 4 Enabled Detecting cu GS BE a Es BE Ee eS ee ee E E E E E Be E E SS eS ee ee E 4 Enabled v Detecting dell Enabled v Detecting 1 2 3 4 5 Enabled v Detecting 6 7 5 Enabled Detecting 9 Enabled Detecting Enabled Detecting 4 En
6. abled Detecting d Enabled Detecting Enabled Detecting 4 Enabled Detecting 4 Enabled Detecting Enabled v Detecting 4 Enabled Detecting 4 Enabled v Detecting 4 Enabled v Detecting 4 Enabled v Detecting 4 Enabled Detecting Enabled v Detecting m Ni Enabled Detecting Enabled Detecting Switch Enabled O Enabled fe Enabled fe Enabled z fie Enabled z fe Enabled z fie Enabled z fe Enabled fe Enabled fe Enabled fe Enabled z fe Enabled z fe Enabled fe Enabled z fe z Enabled fe Enabled fie Enabled z fe Enabled z fe Enabled fe Enabled fe Enabled z fe Enabled fe Enabled fe Enabled fe Enabled z fe Enabled z fe 4 C Submit d Do l l ent Figure 7 Port Power Management Configuration Menu The screen lists the following information for all the switch ports Admin Status Power State The Power over Ethernet status for each port can be configured as one of the following values e Enabled port is currently enabled for delivering power default e Disabled port is configured not to supply power SZ Reviewed Solution amp Interoperability Test Lab Application Notes 9 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc Current Status Displaying the current status of the port e Detecting
7. bled z fe Enabled z fe Enabled fe Enabled fe Enabled fie a Figure 8 Configuring Power Properties for Port 1 3 e Click Submit button as shown in Figure 8 SZ Reviewed Solution amp Interoperability Test Lab Application Notes 12 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc After the screen refresh Figure 9 shows power status for all ports 2 BayStack 460 24T PWR Switch 169 254 100 100 Microsoft Internet Explorer NORTEL Configuration gt Power Management gt Port Property NETWORKS Port Power Setting e Current mA gt SNMPV3 Enabled Delivering Power 16 High 49 0 140 7 036 SNUP Trap Enabled Delivering Power 16 High 489 4 870 MAC Address Table Find MAC Address Enabled Delivering Power 16 49 3 3 178 Port Management High Speed Flow Control 0 0 0 000 Software Download Configuration File 0 0 0 000 ConsolefComm Port 0 0 0 000 Stack Operational Mode WV Power Management 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 93 64 D D D D Global Power Mgmt 0 D D D 0 0 D 0 000 0 D D D D D D D 0 D D 0 4 dale m 4 Enabled v Detecting 4 4 Enabled v Detecting 4 Enabled Detecting 4 Enabled Detecting 1 2 a 4 5 Enabled v Detecting 6 7 8 g 4 Enabled Detecting 4 10 Enabled v Detecting 4 11 Enabled Detec
8. e Refer to Using the BayStack 460 24T PWR Switch for complete information on power pairs http www 130 nortelnetworks com cgi bin eserv cs main jsp level 6 amp category 8 amp subcategory 6 amp subtype amp DocumentOID 8 1409 SZ Reviewed Solution amp Interoperability Test Lab Application Notes 7 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc Traps Control Can be configured as either Enable or Disable PD Detect Type 802 3af Detect IEEE 802 3af 2003 compliant power devices 802 3af and Legacy Detect both IEEE 802 3af compliant and legacy power devices The default setting is 802 3af DC Source Type Select the optional power source type 1 BayStack 10 BayStack 10 Power Supply Unit 2 NEC Network Energy Source NEC from Invensys Energy Systems The default value is BayStack 10 DC Source Configuration Select the DC configuration type The choices are 1 Power Sharing 2 UPS 3 RPSU The default setting is Power Sharing To configure any parameter from this form SZ Reviewed WCH 4 28 2004 Type the information or make a selection from the list Click Submit as shown in Figure 6 Solution amp Interoperability Test Lab Application Notes 8 of 16 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc Power Management Configuration for Port s Follow the steps below to configure power management settings for each port e From the main
9. er will be shut down first SZ Reviewed Solution amp Interoperability Test Lab Application Notes 10 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc Volt V Display the measured voltage supplied by the port Current mA Display the measured current supplied by the port Power Watt Display the measured power supplied by the port To configure power properties for port s e Type the information or make a selection from the list e Click Submit button 4 Verification Steps The following steps can be used to verify proper connection configuration and powering of Avaya IP telephones e To verify that priority can be set to high configure ports 1 3 priority to High as shown in Figure 8 e Plug the Avaya 4620 4612 Gen 2 and 4602SW IP phones into ports 1 3 SZ Reviewed Solution amp Interoperability Test Lab Application Notes 11 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc A BayStack 460 24T PWR Switch 169 254 100 100 Microsoft Internet Explorer File Edit Yiew Favorites Tools Help Back gt amp A A Qsearch Favorites 4bistory B 40 8 N RTEL Configuration gt Power Management gt Port Property NETWORKS Port Power Setting jaiai Current mA Remote Access 1 Enabled Detecting High 00 D 0 000 2 SNMPY1 gt SNMPv3 High yj 0 0 0 000 High 00 0 000 SNMP Trap MAC Address Table Low 0
10. ing Iree Configuration TELNET SNMP Web Access Configuration Software Download Configuration File Display System Log Reset Reset to Default Settings Command Line Interface Logout Use arrow keys to highlight option press lt Return gt or lt Enter gt to select option Figure 3 Switch Console Configuration Main Menu e Select IP Configuration Setup and press lt Enter gt key on keyboard e Enter IP address and subnet mask as shown in Figure 4 In this configuration an IP address 169 254 100 100 255 255 255 0 is assigned to the switch s in band interface IP Configuration Setup BootP Request Mode BootP Disabled Configurable In Use Last BootP In Band Stack IP Address I 6 0 0 6 4 6 0 0 In Band Switch IP Address ERD RIRIR H 6 0 0 In Band Subnet Hask 209 209 209 0 0 0 0 0 0 0 0 0 Default Gateway 0 0 0 0 0 0 0 0 0 6 0 0 IP Address to Ping 0 0 0 0 Start Ping No Enter IP Address 169 254 100 100 Enter text press lt Return gt or lt Enter gt when complete Press Ctrl R to return to previous menu Press Ctrl C to return to Hain Menu Figure 4 Switch In Band IP Address Subnet Mask Configuration e Press lt Enter gt and then Ctrl C to return to the Main Menu when done SZ Reviewed Solution amp Interoperability Test Lab Application Notes 5 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc A Access the switch using a web browser e Co
11. ll Rights Reserved BayStack PoE Config doc e For IP telephones successful registration with an Avaya Media Server Gateway and completion of a test call e For wireless LAN access points successful registration of a wireless laptop and use of the administration web interface on the access point from the laptop Nortel BayStack 460 24T PWR Switch Tek r tt E aasaee ssa Avaya AP 5 F Access Point Avaya 4602 4602SW IP Telephones F ies Avaya AP 3 rs ez Access Point Wireless Avaya 4610SW y jr BARTO IP Telephone Avaya 30A Avaya 4620 4 Ethernet Switch 4620SW IP z Ia Base Telephones with Qa Sa Avaya Gen 1 EU24 s 4612 amp 4624 IP Avaya 4630SW Avaya Gen 2 Telephones IP Screenphone 4606 4612 4624 IP Telephones Figure 1 Avaya 4600 Series IP Telephone and Wireless LAN Access Point Configurations with the Nortel BayStack 460 24T PWR Switch To line jack of 4612 4624 IP Telephone To Ethernet switch port Figure 2 Avaya 30A Switch Base Connections SZ Reviewed Solution amp Interoperability Test Lab Application Notes 3 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc 2 Equipment and Software Validated The following equipment and software were used for the sample configuration provided Equipment 2 2 2 7 7 0 0 0 8 8 Avaya 4620SW IP Telephone Avaya 4620 IP Telephone with EU24 Button Expansion Module 20 Avaya 4630SW IP Scree
12. nfig doc For example Figure 11 shows the power status for port after the power 1s restored File Edit view Favorites Tools Help Back gt x E gt po Search Si Favorites E media 7 rA es Address httpsf 169 254 100 100 Go Links Avaya Solution and Int Port Power Setting NORTEL Current mA NETWORKS i Enabled All E High sal s90 18 5 592 Enabled gt Delivering Power 16 High 40 5 g3 4 726 Access RW oO fe Enabled gt Delivering Power 16 High 49 3 3 170 SMMPY1 gt SNMPy3 SNMP Trap MAC Address Table Find MAC Address Port Management High Speed Flow Contral Software Download Configuration File Consolefloamm Port stack Operational Mode Enabled W W Power Management Global Power Mgrnt Enabled gt Detecting Port Property l gt Fault Enabled W Detecting Enabled gt Detecting 0 0 0 000 Enabled gt Detecting 0 0 0 000 Enabled gt Detecting 0 0 0 000 Enabled gt Detecting 0 0 0 000 Enabled gt Detecting 0 0 0 000 2 3 4 5 E T g z Figure 11 Enabled gt Detecting 0 0 0 000 Detecting 0 0 0 000 0 0 0 000 0 0 0 000 Enabled gt Detecting 0 0 0 000 we t t ie Es Es Es Es Enabled gt Detecting 0 0 0 000 pa 3 r ve az fae S m J m N pd 5 Conclusion The following Avaya IP telephone and wireless LAN access point products were tested with the Nortel BayStack 460 24T PWR Switch and were s
13. nfigure a computer with an IP address in the 169 254 100 0 24 subnet e Launch a web browser and point to http 169 254 100 100 Figure 5 displays the web configuration main menu E BayStack 460 24T PWR Switch 169 254 100 100 Microsoft Internet Explorer File Edit view Favorites Tools Help Bak Gi Seach Cojravorites C4History Ghe Sp Address http 169 254 100 100 NORTEL NETWORKS Administration gt System Information BayStack 460 24T PWR Switch Access RV sysDescription Baystack 460 247 PVVR HAD PY 3 0 5 SVvov2 3 0 09 ISN sysUpTime 2 Days 5 Hours 1 Minutes 3 Seconds gt Summary gt Configuration gt Fault gt Statistics gt Application Y Administration System Information gt Security Logout f Reset dE Reset To Default gt Support sysName sysLocation sysContact Copyrighti 7001 Nortel Networks Inc All vi hts reserved Figure 5 Web Configuration Main Menu SZ Reviewed Solution amp Interoperability Test Lab Application Notes 6 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc 3 Power Management Configuration for the BayStack Switch Follow the steps below to display and configure power settings for the BayStack 460 24T PWR switch e From the main menu navigation panel select Configuration gt Power Management gt Global Power Mgmt The Global Power Management page opens as sh
14. nphone l 1 73 Avaya 4624 IP Telephone Gen 2 0 Avaya 30A Ethernet Switch Base Table 1 Equipment and Software Used for Verification 3 Configure the Nortel BayStack 460 24T PWR Switch This section describes the configuration steps to control and monitor inline power status Either the command line interface CLI or the web based management interface can be used to accomplish these tasks These Application Notes will demonstrate the web based management interface configuration The switch has no IP address assigned by default To use the web based management interface an IP address must be assigned to the switch s in band management interface Assign an IP address to the switch s in band interface via its console port e Connect to the Console port on the switch and set up Hyper terminal with the following parameters 9600 bits per second 8 data bits 1 stop bit no parity and no flow control Connect the BayStack 460 24T PWR switch to AC power After the Nortel Networks logo is displayed press Ctrl Y to display the Main Menu as shown in Figure 3 SZ Reviewed Solution amp Interoperability Test Lab Application Notes 4 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc BayStack 4660 24T PWR Main Menu IP Configuration Setup SNHP Configuration System Characteristics Switch Configuration Console Comm Port Configuration Display Hardware Units Spann
15. own in Figure 6 Note that the total available DTE power is 200 Watts from the switch s AC In order to provide more power to support class 3 PD for all 24 ports an external power supply can be used Address http 169 254 100 100 NORTEL NETWORKS Configuration gt Power Management gt Global Power Management Global Power Management Available DTE Power 200 Watt DTE Power Status Normal Access RW Remote Access SNMP DTE Power Consumption O Watt gt SNMPy3 DTE Power Usage Threshold feo o 1 99 SNMP Trap Power Pair Spare MAC Address Table Find MAC Address Port Management High Speed Flow Control Software Download Configuration File ConsolefComm Port Stack Operational Mode Y Power Management Global Power gmt Port Property Traps Control Enable PD Detect Type 802 361 Power Source Present AC Only DC Source Type BayStack 10 DC Source Configuration Power Sharing Figure 6 Global Power Management Configuration Menu Figure 6 displays the global power management settings for the switch The following parameters are user configurable e DTE Power Usage Threshold Enter the percentage of total power consumption on the switch necessary to trigger an SNMP trap The default setting is 80 e Power Pair Choose the power pair of the RJ 45 pin connectors to supply power The options are spare or signal The default value is spar
16. ting 4 Port Property 12 Enabled Detecting 0 0 0 000 gt Fault gt Statistics 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 0 0 0 000 4 14 Enabled Detecting 4 1 Enabled v Detecting 1 Enabled v Detecting 4 16 Enabled v Detecting 7 Enabled v Detecting 18 Enabled v Detecting 19 Enabled Detecting 20 Enabled Detecting osha 21 Enabled Detecting oe Enabled v Detecting 23 Enabled v Invalid PD 24 Enabled Detecting Switch Enabled I ofj o 4 m EEUE E U OEE EUa OE AAAA AAAA i i ia ia ia ia ia ia ial ial ial ik C Submit Epone O l nee Figure 9 Power Status for all Ports on Switch Note that all three IP telephones are automatically powered up The Current Status is changed to Delivering power and Priority is set to High for ports 1 3 The actual power delivered to ports is displayed also SZ Reviewed Solution amp Interoperability Test Lab Application Notes 13 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc Disabling Power on a Port To disable power on a port e Inthe Admin Status column use the drop down arrow to select Disabled for that port e Click Submit at bottom of the page For example Figure 10 shows the power status for port 1 after the power is disabled Address http 169 254 100 100 NORTEL Configuration
17. uccessfully powered e IP telephones 4602 and 4602S W 4610SW 4620 and 4620SW including EU24 Button Expansion Module 4630S W Gen 1 4612 and 4624 with 30A switch base Gen 2 4606 4612 and 4624 e Wireless LAN access points e AP3 e AP5 SZ Reviewed Solution amp Interoperability Test Lab Application Notes 15 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc 2004 Avaya Inc All Rights Reserved Avaya and the Avaya Logo are trademarks of Avaya Inc All trademarks identified by and are registered trademarks or trademarks respectively of Avaya Inc All other trademarks are the property of their respective owners The information provided in these Application Notes is subject to change without notice The configurations technical data and recommendations provided in these Application Notes are believed to be accurate and dependable but are presented without express or implied warranty Users are responsible for their application of any products specified in these Application Notes Please e mail any questions or comments pertaining to these Application Notes along with the full title name and filename located in the lower right corner directly to the Avaya Solution amp Interoperability Test Lab at SZ Reviewed Solution amp Interoperability Test Lab Application Notes 16 of 16 WCH 4 28 2004 2004 Avaya Inc All Rights Reserved BayStack PoE Config doc
18. w Avaya IP telephones and wireless LAN access points can be connected to the Nortel BayStack 460 24T PWR switch The Avaya product configurations addressed by these Application Notes are shown in Figure 1 The following Avaya products are directly connected to the switch e 4602 and 4602SW IP Telephones e 4610SW IP Telephone 4620 and 4620SW IP Telephones including the optional EU24 Button Expansion Module 4630SW IP Screenphone Gen 2 4606 4612 and 4624 IP Telephones Gen 1 4612 and 4624 IP Telephones with 30A Ethernet Switch Base AP 3 and AP 5 Access Points The Gen 1 Avaya 4612 and 4624 IP Telephones require the Avaya 30A Switch Base 1f power over Ethernet is required Figure 2 shows the connections for the 30A switch base The 4612 and 4624 telephones can be identified as Gen 1 or Gen 2 by inspecting the model number 1A in the model number indicates Gen 1 2A indicates Gen 2 The model number can be found by e Inspecting the label attached to the bottom of the telephone OR e Pressing Mute V I E W on the keypad and then pressing until the model number appears Press to exit Examples of model numbers are 4612D01A 003 Gen 1 and 4612D02A 003 Gen 2 The powering tests included verification of the following after the product was connected to the switch e Successful boot operation SZ Reviewed Solution amp Interoperability Test Lab Application Notes 2 of 16 WCH 4 28 2004 2004 Avaya Inc A

Download Pdf Manuals