Home

AudioSource 12-Channel User's Manual

image

Contents

1. a EE Ela E a allel EE E NOTES ABOUT HUM While the AMP1200 has been designed to minimize the possibility of hum in the audio system it is still possible that a hum will occur in rare circumstances Its safety grounding can create a path for small amounts of 60 Hz energy to travel trough the line level audio system While not dangerous this energy can cause difficulty with the auto signal sensing circuit and at the very least will interfere with the quiet enjoyment of your system The first course of action should be trying to make sure that all ofthe audio components are connected to either the same electrical outlet or at least into the same circuit branch Next cable TV systems are notoriously the culprit so be sure to try disconnecting all coaxial feeds that are connected to the system If this solves the problem install a coaxial line isolator and reconnect the system In the very worst case a line level audio isolator transformer connected to the line in ofthe subwoofer amplifier will usually solve the problem Important Safety Instructions To reduce the risk of electric shock do not remove cover No user service able parts inside Refer servicing to qualified personnel To reduce the risk of fire and shock do not expose unit to rain or moisture The unit should be connected to an earth grounded AC electrical socket The unit s
2. MM AudioSource Twelve Channel Multi Zone Amplifier EE AudioSource AMP1200 Model AMP1200 User Manual www audiosource net Thank you for purchasing the AudioSource AMP1200 Twelve Channel Multi Zone Amplifier The versatility of the AMP1200 makes it the perfect choice for almost every type of custom multi room audio system Its tabletop or rack mountable design allows it to be integrated easily into high end whole house audio systems FEATURES e 12 channels 6 stereo zones in one convenient enclosure e Stable Class AB design delivers superior audiophile sound quality and performance e Independent and bus inputs provides unparalleled flexibility Bridgeable channel outputs provide additional power when needed Independent channel gain controls allow the output of each speaker to be perfectly matched e Switchable 115 230V input voltage Manual auto or triggered on off for integration into any automated system Multi stage protection circuitry for reliability and easy troubleshooting e Installer friendly setup and connections Can be converted easily between rack mount and tabletop configurations Heavy duty steel chassis with brushed aluminum faceplate INSTALLATION AudioSource amplifiers are designed to help deliver a great audio experience However where you place the amplifier can have a large effect on the performance you receive and the life of the unit If you are not rack mounting the amplifier
3. ADGES Em o DC E E OS FRONT PANEL 1 Master Power Switch Indicator LED Front panel pushbutton power switch turns the amplifier on and off When the switch is on and the indicator LED is red the amplifier is in standby mode The remote turn on switch located on the rear is either in the trigger or auto position When the LED is blue the amplifier is fully active The master power switch will turn off the am plifier no matter which power mode has been selected 2 Zone Status Indicators Each pair of channels or zones has a bi color LED to indicate its operational status These indicators provide quick and easy troubleshooting of the system If the circuitry deter mines that a channel must be shut down due to excessive heat or low impedance a short only the channels that are affected will be turned off causing the zone LED to turn red The remaining zones will continue to operate and maintaina blue LED status Once the condition has been corrected for the zone in question the status LED will return to blue Note When the power LED is red and the zone status LEDS are not lit off indicates the unit is in stand by mode REAR PANEL 3 BUS Line Inputs Outputs The AMP1200 has two common or BUS inputs that receives audio signals from standard line level audio sources and sends them to any or all channels The BUS line outputs are direct feed through to allow the BUS inputs to be fed to o
4. L ZONE 1 R 3 30V 12VDC TRIGGER AC DC 500mA MAX 9 Speaker Output Terminals The AMP1200 uses high quality Phoenix style connectors for the speaker connections Use 14 18 gauge stranded two conductor loudspeaker wire Ensure that at least 2 inches of each conductor are separated Strip away Ya inch of insulation from each conductor Connect the appropriate conductor to each screw terminal observing correct polarity Also please observe proper speaker wir ing when bridging channels 10 Individual Channel Input Alltwelve channels have their own dedicated input that allows the connection of audio sources in addition to the common BUS inputs This is useful when using the AMP1200 with an audio matrix switcher 11 AC Voltage Switch The unit is set at the factory for 115V U S operation simply connect the included IEC power cord to your wall outlet For 230V operation move the voltage selector switch to the 230V position When operating at 230V the internal fuse located in the IEC socket should also be changed In most 230V applications a separate power cord will be required and is not included 12 IEC Power Connector The unit comes with an IEC jack that permits removal of the AC power cord This allows the flexibility of chang ing the power cord for different countries The IEC socket also houses the main fuse holder Plug the power cord supplied with the amplifier into the amplifier and a grounded wall outlet o
5. air or replacement as provided under the terms of this warranty Ifthe defective product is discontinued AudioSource may replace the product with an equivalent or superior product at its option Any cost of re installation or repair of wall or ceiling surface is the sole responsibility of the customer and that cost shall not be the responsibility of AudioSource Under no circumstances shall AudioSource be liable for loss or damage direct consequential or incidental arising out of the use of or inability to use the product There are no express warranties other than described above
6. efore the amplifier goes to standby when using the Auto turn on mode 6 Channel Gain Control Each channel has its own independent level adjustment This allows the output level of each speaker to be per fectly matched to its area It can also be used to limit the maximum audio level in a certain area 7 Bridging Switch By simply flipping a single switch two channels can be combined to increase the total power output This is helpful when extra power is needed in certain areas Note The minimum impedance for bridged channels is 8 ohms Also please observe the proper speaker wiring when bridging channels Input selection and volume settings for bridged channels will be controlled by the left channel BR is bridged mode and ST is non bridged or stereo mode CAUTION Only change switch positions when the amplifier is turned off 8 Input Selection Switch Each channel is capable of delivering the source from many inputs The three main inputs are BUS 1 BUS 2 and LINE IN The selection for these inputs is done via the Input Selection switch associated with each channel Select the desired source input Set the Input Selection switch to BUS 1 will play source connected to the BUS 1 input BUS 2 will play source connected to the BUS 2 input or LINE IN will play source connected to that channel s LINE IN CAUTION Only change switch positions when the amplifier is turned off CLOSE UP OF CONNECTIONS a
7. harges associated with the removal and re installation of speakers for the limited period and all parts and labor charges after the limited warranty period expires The limited warranty period for factory refurbished products expires after ninety 90 days from date of original purchase This limited warranty applies only to purchases from authorized AudioSource Retailers or Distributors This limited warranty is extended only to the original purchaser and is valid only to consumers in the United States Consumers are required to provide a copy of the original sales invoice from an authorized AudioSource Retailer or Distributor when making a claim against this limited warranty This limited warranty only covers failures due to defects in materials or workmanship that occur during normal use It does not cover failures resulting from accident fire flood misuse abuse neglect mishandling misapplication alteration faulty installation modification service by anyone other than AudioSource or damage that is attributable to Acts of God It does not cover costs of transportation to AudioSource or damage in transit The customer should return their defective product freight prepaid and insured to AudioSource only after receiving a Return Authorization Repair or replacement under the terms of this warranty does not extend the term of this warranty Should a product prove to be defective in workmanship or material the consumer s sole remedies will be rep
8. hould be operated in a well ventilated area Minimum clearance is 2 inches from the ventilation openings Note Unitis set at the factory for 120V operation Be sure to change the fuse 4A rating before switching to 230V operation Two Year Limited Warranty Rated Power Output Bridged Power Output Input Sensitivity Input Impedance Frequency Response SPECIFICATIONS 40 Watts per channel RMS at 8 ohms 80 Watts per channel RMS at 8 ohms 8 ohm minimum 380 mV for full output with all level controls at max 18K ohm 5 Hz to 72 kHz Distortion 005 THD 20 Hz 20 kHz O 30W 8 ohm Distortion Bridged 010 THD 20 Hz 20 kHz O 80W 8 ohm Channel Crosstalk 80 dB Signal to Noise Ratio 105 dB A weighted Efficiency 63 Power Requirements Stand By Power Rating Auto Turn On Sensitivity Dimensions Weight 115 230 VAC 50 Hz 60 Hz 115V 0 264W 13 7mV 16 7 W x 4 H including feet x 14 25 D 30 Ibs The AMP1200 complies with the CE EuP directive CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN WARNING SHOCK HAZARD DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR AudioSource a division of Peak Audio Group warrants this product against defects in materials and workmanship for a limited period of time For a period of two 2 years from date of original purchase we will repair or replace the product at our option without charge for parts Customer must pay for all labor c
9. posi tion it with all feet resting on a solid level surface Be sure that the amplifier is in a well ventilated area and DO NOT install the amplifier near a source of heat or in an extremely humid or wet location CAUTION All connections and switching must be done with the amplifier s power switch positioned to Off Connect the power cord last to be sure that the amplifier is off during all of your connections and set up EE AudioSource AMP1200 L ZONE 6 R Ds s Qvo BUS Em 2 LINE IN L ZONE 5 R vOs sQ VOL L ZONE 4 R Q Do L ZONE3 R OO VOL L ZOJE2 R Ol Do ZONE1 R D er Bilis O voL T E LINE IN BUS BUS 1 2 LINE IN Tii s LINE IN a B LINE IN LINE IN i BA LINE IN H E LINE IN Hi a LINE IN i Hr LINE IN i sr LINE IN it 2_LINE IN LINE IN LINE IN E nO SL Um IN LINE IN LINE IN LINE IN LINE IN LINE IN LINE IN tm IN Le nE Fics TALAN AC FORNACE O D 6 Fuse T4AL 250AVC FOR 230VAC 50Hz L SPEAKER E R SPEAR pa E o ki E BRIDGE s R SPEAKER L SPEAKER E L R SPEAKER SPEAKER L R SPEAKER SPEAKER E E ela Elo EE no v m gt D A m y Es E e Le o Hp Hp El _ HH e BH gt BE So os SS os So BRIDGE B
10. r appropriate surge protector CAUTION a switched outlet such as what is provided on some Sur round Receivers If you wish to have the amplifier turn on when the Receiver is powered up use one of the power modes such as Trigger or Auto DO NOT plug the amplifier s power cord into TYPICAL 6 ROOM INSTALLATION OUTPUT AM FM RECEIVER E OL CD PLAYER OR AUX TAPE CD a INPUT INPUT INPUT caged LR LR LR OL TAPE DECK oo 0 00 E OR OUTPUT a MP 3 IPOD a PLAYER AAA o O i ER GEN j L ZONE 1 R a L ZONE 2 R L ZONE 3 R L ZONE 4 R L ZONE 5 R L ZONE 6 R MH N O E ora O Monn mor vo O er sr O vo vo O an Non voL s i O voL vo O er up ER o Rol Ro Bol o Bol Lo Teo Bol Bo He Elli 1010 0 0 0 0 0 0 O OQ or TPU PEN KER SPE AKER SPEAKER FEAREN PENER spencer SPEA SPEER SPEAKER SPEAKER Ponen SPEAKER M ii il Gi SS gt l a OO e SIL doca Rem EM E rane A 6 nose A bribe amp BRIDG A BRIDGE AS Ae mne Si AC OH ROOM 1 ROOM2 7 ROOM3 ROOM 4 2 ROOM5 2 ROOM6
11. ther amplifiers Be sure to use high quality RCA cables that feature low impedance shielding and high quality connectors 4 Remote Turn On Switch This switch selects the turn on stimuli that will puttheampli fier in ready mode Trigger setting relies on 3 30V AC DC voltage going into the trigger input to activate the amplifier Auto setting senses a signal on the RCA line level inputs and automatically puts the amp in ready mode On setting puts the amp constantly in ready mode so that it can be controlled by the master power switch on the front panel In Auto mode the amplifier will take approximately 15 minutes to return from ready to standby mode 5 Trigger Input Output The trigger input is a handy feature when connecting the amplifier to an automated audio system The 3 5mm mini plug jack will accept a 3 30V AC DC output from another device or from a separate power supply When the trigger inputis energized the amp turns from standby to ON mode When using the AMP1200 with a receiver without a trigger output the voltage can come from a 12V wall wart 3 5mm tip positive connector plugged into the receiver s switched outlet and the trigger input The AMP1200 can also provide an output trigger voltage 12DC 500mA max to turn on and off other devices in the audio system Whentheampli fier turns off standby mode the voltage will drop to zero Note Remember there is a delay of approximately 15 minutes b

Download Pdf Manuals