Home

Aube Technologies TI054A-06-3W User's Manual

image

Contents

1. that the lights go on at 5 00 the lights will not go on that morning 3 If you wish to replace the sundown and or sunrise programs by a fixed hour select the P1 ON or P2 OFF programs and enter new parameters using the HOUR and MIN buttons SAVING YOUR PROGRAMS 1 Press on the PGM button to select the program 2 Use the HOUR and MIN buttons to modify the program 3 Press on the CODE button to return to the initial value P1 ON Sundown P1 OFF P2 ON P2 OFF Sunrise 4 Press on the SAVE button to record your modifications and return to the MANUAL or AUTOMATIC operating mode TO SWITCH FROM STANDARD TIME TO DAYLIGHT SAVING TIME If your country uses daylight saving time execute the following proce dure when the time changes 1 Press 4 times on the CODE button to select the nor Ad mode 2 Use the MIN button to switch from the nor Standard mode to the Ad Daylight saving mode and vice versa 3 Press on the SAVE button to return to the MANUAL or AUTOMATIC operating mode The programmable switch will automatically adjust the clock and the sundown sunrise table for the period of the year You do not need to adjust the clock manually MEMORY PROTECTION The programmable switch is equipped with a rechargeable battery that will protect your program recordings during a power failure Note that the screen is not ON during power outage CHARACTERISTICS Model
2. TI054A 06 3W Supply 240 VCA 50 60 Hz Load 15 watts min 500 watts max Approvals CE Storage temperature range 20 to 50 C Operating temperature range 0 to 50 C Max latitude 65 Precision of the solar table 11 min max error near the Poles tar one GREECE 39 22 WARRANTY AUBE TECHNOLOGIES INC ONE YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year from the date of the original pur chase from authorized dealers Warranty does not cover transportation costs Nor does it cover a product subjected to misuse or accidental damage This limited warranty is in lieu of all other warranties obligations or lia bilities expressed or implied by the company In no event shall AUBE Technologies inc be liable for consequential or incidental damages resulting from installation of this product Within this period any product proven defective in normal use will be repaired or replaced at AUBE s option without charge for either parts or labour provided that the defective product with the original sale receipt is returned to the original dealer or is shipped pre paid insured and addressed to Head Office ii Aube technologies inc 705 Montrichard 10 rue Ampere Iberville Quebec 95500 Gonesse Canada J2X 5K8 France Tel 450 358 4600 Tel 33 0 1 34 07 99 06 Fax 450 358 4650 Fax 33 0 1 34 07 99 19 www aubet
3. Use the HOUR and MIN buttons to enter the day 4 Press again on the CODE button The screen displays nor normal Use the MIN button to switch from Standard time nor to Daylight Saving time Ad 5 Press again on the CODE button The screen displays LC 0 Use the MIN button to enter the local correction factor You have now completed the setting of your parameters Press on one of the SAVE buttons to record your parameters and return to the MAN UAL or AUTOMATIC operating mode 920 054 001 00 1 0 2 3 DEFINING YOUR PROGRAMS 1 This switch can memorize 2 ON OFF programs which repeat themselves every day If you have entered your city s parameters the programs P1 ON and P2 OFF represent sundown and sunrise hours Our example shows these results If your switch is set at AUTO your lights will go on at sundown and go off at sunrise 2 If you wish your lights to go on at sundown but go off for example at 23 00 enter program P1 OFF 23 00 Furthermore if you wish your lights to go back on at 5 00 AM and go off at sunrise enter program P2 ON 5 00 nor Standard time Winter time Ad Daylight saving time Summer time Note that the P1 OFF and P2 OFF programs have priority on the P1 ON and P2 ON programs respectively If for example the sun rises at 4 58 P2 OFF and you request in P2 ON
4. terminal 1 240 VAC PHASE RED 50 Hz x FOR AN EXISTING THREE WAY SWITCH INSTALLATION To replace a conventional three way switch by a programmable one follow the following wiring diagram 240 VAC PHASE RED 50 Hz a ZS NEUTRAL s G BLUE oo a MARRON The common wire phase that you identified while removing the existing three way switch must be connected to one of the two C ter minals on the programmable switch Connect the other two wires black to the remaining two terminals on the programmable switch The connecting wire supplied will be added to the remote three way switch between the common terminal and the black wire connected to terminal C on the programmable switch Once the connection is com pleted correctly install the switches in their own electrical box and close the main circuit breaker to reinstate the power supply FUNCTION CHECK Refer to the START UP section to start the programmable switch Try to activate the lighting using the remote switch and the programmable switch If everything is in working order the installation is complete Otherwise cut the power supply at the main circuit breaker and recon nect the connecting wire on the remote switch between the common terminal and the other terminal FOR A NEW THREE WAY INSTALLATION For a new installation you may use a single pole switch at the remote location Use the following wiring diagram N
5. ON OF YOUR CITY S PARAMETERS Before programming your switch complete the following table by answering the questions Latitude Longitude DAY nor Ad 1 LATITUDE amp LONGITUDE What are the latitude and longitude of your residence Identify the city closest to yours in the table If none is listed in the table this information is usually available on road maps latitude horizontal lines and longitude vertical lines Ex Paris 48 2 means Latitude 48 N and Longitude 2 E Note that SOUTH latitudes and WEST longitudes are indicated with a minus sign The maximum latitude is 65 2 DAY What is the day of the year Add the month code see table below to the day s date Ex If today is June 24th DAY 151 24 175 P1 ON 21 50 Sundown PI free P2 ON free P2 OFF 5 58 Sunrise January 0 July 181 February 3 August 212 March 59 September 243 April 90 October 273 May 120 November 304 June 151 December 334 3 nor Ad Does your country use daylight saving time advanced time in the summer If so in which period of the year are you Ex In France on June 24th we are in daylight saving time Ad nor Ad Ad Pl ON 20 38 Sundown Pl OFF 22 00 P2 ON 5 00 P2 OFF 5 10 Sunrise LC Does your country follow the rules of the standard time according to its position in relation to Greenwich or has it set the t
6. aube technologies PROGRAMMABLE THREE WAY SWITCH MODEL TI054A 06 3W FOR ALL LIGHTING SYSTEMS MAXIMUM CHARGE MUST NOT EXCEED 500 W 230 V The T1I054A 06 3W three way switch MAY be installed on EITHER of the following lighting systems Incandescent Halogen Low voltage halogen with transformer Fluorescent It must not be installed on a motor or a charge exceeding 500 W INSTALLATION This programmable switch may be used in either a single pole or a mul tiple pole switch installation Multiple pole switch installations with an electronic switch are different from conventional installations Read the wiring instructions carefully and select the one that applies to your situation You must follow the steps in the indicated order at all times Note Please note that the two 2 C terminals on the programmable switch have no polarity They can both be used indiscriminately 1 Cut the power supply at the main circuit breaker in order to avoid the risk of electrical shock 2 Remove and disconnect all existing three way or regular switches In the case of a three way switch identify the wire connected to the C or common terminal 3 Connect each wire as it is disconnected to the programmable switch following the appropriate wiring diagram 4 Close the main circuit breaker to reinstate the power supply FOR A SINGLE POLE INSTALLATION For a single pole installation no wire is connected to
7. ech com www aubetech com service aubetech com advaube comintes com E Carrer Segur 74 08035 Barcelona Espa a Tel 34 93 420 28 73 Fax 34 93 429 30 79 www aubetech com reutor teleline es 920 054 001 00 1 0 3 3
8. ime in a more practical way Since this programmable switch can be used anywhere in the world it is based on the universal time 24 time zones each increasing by one hour toward the East starting at Greenwich For practical reasons how ever some time zones have been redefined in order to respect a fron tier or for reasons of economy In this case to remain compatible with the universal time you need to enter a local correction factor Ex Since the second world war France has adopted Central European time GMT 1 Thus its local correction factor will be LC 1 SETTING THE TIME 1 Lift the lower side of the door with a flat screwdriver 2 Set the time by pressing on the HOUR and MIN buttons 3 Press on one of the SAVE buttons to record the time and return to the MANUAL or AUTOMATIC operating mode RECORDING YOUR PARAMETERS Now you only need to program the parameters previously defined into your programmable switch Note If you make a mistake while entering data select the ill defined parameter again using the code button and make the appro priate correction 1 Press once on the CODE button The screen displays Latitude 00 Use the HOUR and MIN buttons to enter your latitude 2 Press again on the CODE button The screen displays Longitude 000 Use the HOUR and MIN buttons to enter your longitude 3 Press again on the CODE button The screen displays Day 000
9. ote Note that the connecting wire supplied is not used in this installation 240 VAC PHASE RED 50 Hz K NEUTRAL BLUE START UP For the first trial under power use a paper clip to push on the R button You should see the figures 0 00 flashing on the screen If nothing appears on the screen check the following points a The programmable switch fuse may not be installed properly or may be defective b Ifthe programmable switch controls a lamp with its own switch make sure that the latter is always ON 920 054 001 00 1 0 1 3 FUSIBLE O 25A O OPERATING MODES The programmable switch offers two operating modes MANUAL and AUTOMATIC In MANUAL mode it operates as a conventional switch You can then turn the light OFF or ON by pressing on the door The screen dis plays MAN and the status of the light ON or OFF In AUTOMATIC mode the switch runs the recorded program To acti vate this mode press on the door approximately 3 seconds until AUTO is displayed The screen displays the active program number as well as its ON or OFF status To temporarily override the programming simply press on the door The new status of the light flashes to indicate that this status is tempo rary To exit the AUTO mode press on the door approximately 3 seconds until MAN is displayed DEFINITI

Download Pdf Manuals

image

Related Search

Related Contents

TMQ Vol I.i - tim  CONCOURS EXTERNE D`INGÉNIEUR TERRITORIAL  Toshiba Satellite P775-S7365  Bedienungsanleitung EVO-SMT200 (pdf, 0,91MB, deutsch)  Freeze Drying - Fisher UK Extranet  TouchChecker  Manual de Usuario  OTS-SFIN86 Final SMS Edition Spy phone_EN  Electric Blanket Manual Manual for BioSmart Electric Infrared Blanket  Samsung GT-C5510H User Manual  