Home
Asante Technologies FS5016 User's Manual
Contents
1. FriendlyNET Plug and Play Networking Solutions Quick Installation Guide FriendlyNET FH416 Fast Ethernet Switching Hub FriendlyNET FS5016 Fast Ethernet Switch 7 ASANIE Making Networking Simple Introduction Thank you for purchasing an Asant FriendlyNET 10 100 Fast Ethernet hub switch This product is designed to be the most affordable way to grow your home or small office network HM Compatible with all industry standard 10BaseT and 100BaseTX network adapters switches hubs and routers M Easiest to install connect power network cables and be running in three minutes or less M Quickly monitor your network with multi colored LED indicators M Expand your network with Auto Uplink technology FH416 only M Free telephone technical support when used with Mac OS Linux Windows 95 98 Me and Windows NT 2000 Professional Server This product is available in two configurations M FriendlyNET 16 port 10 100 Mbps Fast Ethernet switching hub FH416 E FriendlyNET 16 port 10 100 Mbps Fast Ethernet switch FS5016 Packing List Your package contains the following items M 1 FriendlyNET 10 100 Fast Ethernet hub switch M 1 Quick Installation Guide this document M 1 External power module System Requirements Compatible with Apple Mac OS Linux Microsoft Windows 95 98 Me XP and Windows NT 2000 Professional Server Requires a 10 100 Mbps Fast Ethernet port for each workstation server or printe
2. FriendlyNET Hubs amp Switches FH416 FS5016 Tested To Comply C With FCC Standards FOR HOME OR OFFICE USE
3. follow the troubleshooting tips below M Check your power connection Is the green Power LED on If not plug the power module into a different AC outlet M Check your network cable Is the green network Link LED on If not try connecting a known good Ethernet network cable between your hub and the adapter You should see a Link LED on your hub and your network adapter mM The maximum distance from any node computer printer hub switch etc is 328 feet or 100 meters Be sure your Category 5 UTP cable is not coiled twisted or damaged When connecting the hub to a computer be sure your cable is wired for straight through pins 1 2 3 and 6 should be matched pin for pin on both ends Note that pins 3 and 6 must use the same twisted pair these are typically orange white orange or green white green M Check your computer s software Check your operating system manual for instructions on configuring your network for file and print sharing Need more help Consult the Asant website www asante com for additional troubleshooting tips and frequently asked questions FAQ You may also contact Asant Technical Support during standard business hours 7am to 6pm MST Monday Friday Email support asante com Phone 800 622 7464 or 801 566 8991 FAX 801 566 3787 Product Specifications Network Models Error Protection Error Correction Expansion Power Emissions Auto negotiation of IEEE 802u Fast Ether
4. Amber LED is on for 100 Mbps it s off for 10 Mbps c Link Activity Green LED is on when there is a valid network link to the network adapter It flashes during network activity transmit or receive FriendlyNET 16 Port 10 100 Ethernet Switch TVASANIE FriendlyNET 16 port 10 100 Fast Ethernet Switch ey 100 Mops Front Panel FS5016 A B A Power Green LED on when power is ON B Link Activity Yellow LED on if there is a valid 100 Mbps link established and flashes during data exchange Green LED on if there is a valid 10 Mbps link established and flashes during data exchange C Full Duplex Yellow LED on if the port is connected at full duplex Visit Asante at www asante com Main Corporate Telephone Numbers 800 662 9686 Home Office Solutions 800 303 9121 Enterprise Solutions 408 435 8388 Technical Support 801 566 8991 Worldwide Technical Support Fax 801 566 3787 71 ASANTE Making Networking Simple Copyright 2002 Asant Technologies Inc Asant and FriendlyNET are registered trademarks of Asant Technologies Inc AeroLAN and the Asant logo are trademarks of Asant Technologies Inc All other brand names and products are trademarks or registered trademarks of their respective holders All features and specifications are subject to change without prior notice 06 00585 02 04 02 Troubleshooting Tips In the unlikely event your network is not operating properly
5. net 100BaseTX or IEEE 802 3 Ethernet 10BaseT FH416 16 port 10 100 dual speed Fast Ethernet switching hub with Auto Uplink RJ 45 connectors FS5016 16 port 10 100 Fast Ethernet switch with Auto Uplink RJ 45 connectors Automatically isolates faulty ports auto partition and reconnection Automatic polarity detection and correction Auto MDI MDIX FH416 only Any port may be used for uplink to additional hubs or switches with Asante Auto Uplink technology 12 VDC AC power module included FCC Class B CE Operating Environment Temperature Humidity 32 104 F 0 40 C 10 95 non condensing Safety and Regulatory Compliance FCC Compliance Statement This hardware device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference ina residential installation However there is no guarantee that interference will not occur in a particular installation If you suspect this equipment is causing interference turn your unit on and off while your radio or TV is sh
6. owing interference If the interference disappears when you turn the unit off and reappears when you turn the unit on something in the unit is causing interference You can try to correct the interference by one or more of the following measures 1 reorient or relocate the receiving antenna 2 increase the separation between the equipment and the receiver 3 connect the equipment to an outlet on a circuit different from that to which the receiver is connected 4 consult the place of purchase or an experienced radio television technician for additional suggestions Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Safety Advisory 1 This product should be operated from the type of power source indicated on the marking label If you are not sure of the type of power available consult your dealer or local power company 2 Do not allow anything to rest on the power cord Do not locate this product where people will walk on the cord 3 Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock Never spill liquid of any kind on the product 4 Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage points or other risks Refer all servicing to service personnel
7. r Warranty Two years of free telephone support 7AM to 6PM MST 24 hour support via web and ftp with two year product warranty Product Registration To register your Asant product please visit http www asante com support registration html Installation Here s how to install this network hub switch FreindlyNET FH416 Fast Ethernet Switching Hub ET Te elo tel 12VDC 16 15 Uplink to existing hub or switch from any port a D FriendlyNET 10 100 Ethernet Adapters Connect a network cable from this hub switch to your computer s Ethernet port If your computer does not have an Ethernet port you ll need to install an Ethernet network adapter available separately into your computer FH416 with Asante s Auto Uplink technology you can uplink to an existing hub or switch by connecting a network cable from any port on this switching hub FS5016 Connect a network cable from this switches Uplink port to any standard non uplink port on another hub switch or router Plug in the power cord into the unit and plug the external power module into an electrical outlet In a few moments you will see the status of your network with these LED indicators FriendlyNET 16 Port 10 100 Ethernet Switching Hub 7 ASANTE FriendlyNET 16 port 10 100 Fast Ethernet Switching Hub Link Power activity Front Panel FH416 A A Power Green LED on when power is ON B 100 Mbps
Download Pdf Manuals
Related Search
Related Contents
[mailcredit / DEU] Benutzerhandbuch Cypress CY7C63413C User's Manual Westinghouse CCR40WBR Use and Care Manual 1 133 I220 CONTROLLER Sony VGN-BZ560 Safety Information FG 95 Kontakt-Grill SLM / SLG Installation & User Manual Can Fan 340710 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file