Home

American Standard Whirlpool/Bathing Pool 2675 Series User's Manual

image

Contents

1. 42 Gal 159 L 14 1 4 In 362mm Sq Ft 213 Kgs Sq m 15 6 CUBE FT 29 6 PUMP WHIRLPOOL ELECTRICAL SPECIFICATIONS 1 1 HP 9 9 AMPS 120V NOTE Deck mounted fittings are not recommended FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e Tile Bead Kit 751755 100 e Apron Kit List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 2x3or 2x4 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 15 amp GFI e Personal Safety Outlet Cement Plaster Grout Equipment e Caulking Gun GENERAL INSTALLATION INFORMATION Carefully uncrate peel out protective film and inspect your new bath for any shipping damage If such damage is found report it to your vendor i
2. 464mm 18 1 4 A XN LEVELING STRINGER ae NOTE Tile bead kit not included and must be purchased separately TYPICAL PIER TYPE INSTALLATION AS DESIRED 1486mm 58 1 2 CUTOUT 464mm 18 1 4 LEVELING AS DESIRED STRINGERS LEVELING SURFACE WATERPROOF l SEALANT ACCESS PANEL WHIRLPOOL ONLY WHIRLPOOL ONLY UNLESS AN ACCESS OPENING OF AT LEAST UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED WARRANTY SERVICE WILL NOT BE PERFORMED 752445 100 Rev E 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wir
3. COLONY 5 HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS Americam Standard 2675 SERIES WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 1 1 2 O D TAILPIECE sak 1524 mm a 305 mm gt 60 216 mm 12 OUTLINE OF CUTOUT 8 1 2 e 1486 mm x 794 mm 19 mm _ ja 68 1 2 X 31 1 4 3 4 A FINISHED SEE FITTING WALL SPECS FOR gt DIMENSIONS 832 mm 32 3 4 416 mm 16 3 8 1 4 C L OF SUPPLIES i C L OF yf SHOWER ARM OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN C L OF 1651 amp 1981mm VALVES 7 65878 cio ange OVERFLOW m w 2 SPOUT 1 1 2 ATEA 79 mm 02 mm E LEVELING STRINGER 3 1 8 4 NOT FOR a S ty fN l 502mm f a CN 19 3 4 464 mm ROUGH 18 1 4 1 FLOOR BATH 1 1 2 N P T M rA 7 SUPPORT THREADS 70 mm I MATERIAL 2 3 4 17mm 4 5 8 ON OFF SWITCH INSTALLED SIZE WEIGHT GENERAL SPECIFICATIONS FOR 2675 WHIRLPOOL 60 x 32 3 4 x 19 3 4 In 1524 x832 x 502mm WEIGHT w WATER 95 Lbs 43 Kg 604 Lbs 275 Kg GAL TO OVERFLOW 61 Gal 230 L BATHING WELL AT RIM FLOOR LOADING PROJECTED AREA PTS WHIRLPOOL MIN OPERATING VOL BATHING WELL AT SUMP 2 0 x 39 In 508 x 991mm 27 1 2 x 56 In 699 x 1422mm WATER DEPTH TO OVERFLOW 44 Lbs
4. e circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ELECTRICAL INSTALLATION 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752445 100 Rev E 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor for copper conductors Hi Performance l only Always follow Rating 115V Power Line local and national 1 1 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be compl
5. eted using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752445 100 Rev E 4 sPic AND SPAN Is A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
6. mmediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks If a whirlpool do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping har ness at any time 752445 100 Rev E American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional
7. opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 As shown in Fig 1 mark the position of the underside of the deck by tracing a line onto the studs at the height indicated using a level or other suitable straight edge 2 With the top of the 2 x 4 stringer touching the traced line attach the stringer to the studs 3 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 4 This bath must be supported along its entire bottom in all types of installations We recommend the use of mortar or plaster as bedding material sand is not recommended Apply enough bedding to support the complete bottom of the bath After the bedding has been poured and before it sets lower the bath into place until the rim is leveled against the leveling stringers see Typical Installation Methods The rim of the bath MUST NOT support weight Allow the bedding material to completey harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath FIG 1 Sie WALLBOARD TILE BEAD STRIP SEALANT BATH ADHESIVE