1. CONNECTORS TOOLS REQUIRED Fig 2 1 Hex Wrench Included 4 Phillips Screwdriver 2 Adjustable Wrench 5 Tape Measure 3 Plumbers Putty or Caulking INSTALLATION fl INSTALL SPOUT ASSEMBLY Fig 1 ENON rire sers seanna 1 Make sure O RING SEAL 9 is installed 2 Installation with ESCUTCHEON 1 optional Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY IMPORTANT Do not PLATE 1 Only if mounting surface is uneven Paapaa A a tito ac 3 Insert supply HOSES 2 SHANK 3 and POWER CORD E 10 if equipped through hole in ESCUTCHEON with PUTTY PLATE 1 and mounting surface Follow mounting instructions below to secure faucet to mounting surface Make sure PIN 7 is in back 4 Installation less ESCUTCHEON 1 IMPORTANT Do not use putty when installing faucet without escutcheon 5 Assemble RUBBER WASHER 4 BRASS WASHER 5 and THREADED LOCKNUT 6 onto SHANK 3 from underside of sink or mounting surface Hand tighten LOCKNUT 6 6 Use a screwdriver to tighten SCREWS 8 on LOCKNUT 6 Work your way around LOCKNUT 6 tightening the screws slightly each time until all are snug to ensure even pressure A CONNECT POWER SUPPLY Fig 1a 7056 series only 1 Connect the sensor cable 1 to the POWER SUPPLY CABLE 2 2 Code approved Electrical Outlet provided by others 120V 50 60 Hz Holl OUTLET 3 Plug AC POWER SUPPLY 3 into Outlet 120V 50 60 Hz M965255 REV 1 6
2. E MAKE WATER SUPPLY CONNECTIONS Fig 2 1 Turn off hot and cold water supplies before beginning 2 Connect HOSE ADAPTERS 3 to wall supplies if required Connect FLEXIBLE SUPPLIES 1 2 directly to HOSE ADAPTERS 3 3 Connect left supply Marked with a Red Stripe to Hot and right supply Marked with Blue Stripe to Cold supply Use adjustable wrench to tighten connections Do not over tighten 4 Faucet supplies are 18 long from faucet base Note If additional supply length is required installer must purchase those parts separately Important If SUPPLY HOSES 1 2 are too long loop as illustrated to avoid kinking A INSTALL OPTIONAL MIXING VALVE Fig 3 For 7055 105 115 amp 7056 105 115 Faucets Note For complete detailed installation and operating instructions see installations instructions supplied with mixing valve No M968808 No M968808 MAINTENANCE H HAND WASH SENSOR OPERATION Fig 1 REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE When the Sensor detects a user the water immediately starts to flow Water flow will stop two seconds after user is out of sensor range The off delay allows the user to comfortably move his hands without the flow cycling on to off As a precaution a safety timer will turn off the water after the sensor has been blocked for 59 seconds The water will stay off until the blockage is removed from the detection zone Detection Zone
3. 2 10 50 8mm 254mm Default Set at Factory 6 152 4mm SELECTRONIC Thermostatic Mixing Valve 605XTMV a G e p 5 S i G e par vo G erican Standard Faucets visit o ucetsupport amstd com mall u For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 M965255 REV 1 6 A HOW TO CHANGE SENSOR RANGE Factory set at 6 Fig 2 1 Setting the Detection Zone Distance Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off Fig 2 2 Disconnect the BLACK POWER SUPPLY CONNECTOR 1 and reconnect Fig 3 3 While the SENSOR CONTROL LED 2 is blinking slowly place your hand 1 2 in 25 4 50 8mm in front of the sensor Fig 4 4 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set 6 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten Fig 2 1 on 25 4mm 50 8mm REMOVE M965255 REV 1 6 E HOW
4. Check and clean aerator and strainer There is no flow out of faucet when I m in the sensor range Check sensor If sensor blinks 2 times interrupted by pause replace battery or call 1 800 442 1902 What is the normal operating pressure range Faucet will operate with supply pressures ranging from 20 80 psi 7 M965255 REV 1 6 j SELECTRONIC A mcam Stamdar a Proximity Integrated Faucet with Above Deck Mixing PRODUCT NUMBERS sapcananeon 7055 105 7055 205 M900540 00 7055 115 7055 215 E 7056 105 7056 205 M900541 0020A 7056 115 7056 215 FAUCET COVER FOR MIXING VALVE A912790 0070A VALVE STEM O RINGS A923654 0070A BATTERY 6VCR P2 M964171 0070A 1 5 GPM AERATOR M964172 0070A 0 5 GPM AERATOR M3950514 0070A BATTERY HOLDER M964188 0070A COLLAR NUT amp TEMPERATURE A LIMITER STOP C Oo d w M964187 0020A LEVER ASSEMBLY M954483 0070A SOLENOID VALVE M951479 0070A DIVERTER CARTRIDGE M964173 007L0A SENSOR M911785 0070A SPOUT O RING M920013C 0070A COLD SUPPLY HOSE M920013H 0070A HOT SUPPLY HOSE amp M964333 0070A a HOSE ADAPTER M950317 0070A AC POWER SUPPLY 705P400 ESCUTCHEON HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 M962146 0070A Weekdays 8 00 a m to 8 00 p m EST MOUNTING KIT IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays
5. TO INSTALL AND CHANGE BATTERY Fig 5 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Remove BATTERY HOLDER 1 from FAUCET BODY 2 3 Remove old battery from the BATTERY HOLDER 1 4 Install NEW BATTERY 3 into the BATTERY HOLDER 1 Replace BATTERY HOLDER 1 into the FAUCET BODY 2 5 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten See Fig 2 in this section H HOW TO REPLACE SENSOR Fig 6 7 amp 8 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Disconnect both WIRE CONNECTIONS Fig 6 3 Untighten SENSOR SCREW 1 with a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET BODY 3 Remove SENSOR 2a from CARRIER 4 and replace with new SENSOR 2a Install SENSOR ASSEMBLY 2 into FAUCET BODY 3 Tighten SENSOR SCREW 1 Fig 7 8 4 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten See Fig 2 in this section DISCONNECT WIRE CONNECTIONS z i pa Ff 2 5mm HEX WRENCH em M
6. 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2012 8 M965255 REV 1 6
7. 965255 REV 1 6 H HOWTO CLEAN FILTER SCREEN ON SOLENOID VALVE Fig 9 amp 10 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW DISCONNECT 4 at the back of the FAUCET Pull FAUCET COVER aan NECTION 1 up and off See Fig 2 in this section 2 Disconnect WIRE CONNECTION 1 to SOLENOID VALVE 2 Fig 9 3 Unthread SOLENOID VALVE 2 from VALVE BODY 3 Fig 9 4 Remove FILTER SCREEN 4 from base of SOLENOID VALVE 2 Rinse clean and replace Fig 10 5 Thread SOLENOID VALVE 2 into VALVE BODY 3 and hand tighten Reconnect WIRE CONNECTION 1 Fig 9 6 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten See Fig 2 in this section Gi HOW TO REPLACE DIVERTER CARTRIDGE Fig 11 amp 12 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Pull out LIMITER STOP 1 from the VALVE STEM 2 Unthread COLLAR NUT 3 from VALVE BODY 4 Fig 11 3 Pull DIVERTER CARTRIDGE 5 out and replace with new DIVERTER CARTRIDGE 5 NOTE Make sure the two ALIGMENT PINS 6 in the base of the DIVERTER CARTRIDGE 5 are facing upward 4 Replace FAUCET COVER 1 and LEVER HANDLE 3 Instal
8. SELECTRONIC 7055 105 7055 205 Proximity Integrated Faucet 7055 115 7055 215 with Optional Above Deck Mixing 7056 105 7056 205 e Flexible Selectronic Platform with Universal Sensor 7056 1 1 5 7056 21 5 e Easy installation All electronics in the spout nothing below deck e User adjustable above deck mixing uses ceramic disc valve for dependability amp long life e Mixing handle can be removed for one time temperature setting during installation e Available in DC Battery amp AC versions How to Install 2 3 Maintenance 3 FAQ s 1 8 Certified to comply with ASME A112 18 1M Replacement Parts 2012 American Standard Americam Standard NOTE TO INSTALLER Please give this manual to the customer after installation Installation Instructions M965255 REV 1 6 To learn more about American Standard Faucets visit our website at www americanstandard us com or U S customer s e mail us at faucetsupport americanstandard com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin U N PAC KI N G All American Standard Faucets Are Water Tested At Our Factory Some Residual Water May Remain In The Faucet During Shipp
9. ing 1 Remove the fitting and loose items from the carton The illustration below shows the fitting and all loose items after they have been removed from the carton Some items may be packaged partially assembled to other items 1 Selectronic Spout Assembly 4 4 Deck plate optional must be ordered separately 2 Mounting Kit 5 Mixing Valve optional must be ordered separately 3 Battery 7055 Series 6 Key for vandal resistant aerator 3a AC Power Supply 7056 Series 7 Installation Instructions 8 Hose Adapters PRODUCT No s PRODUCT No s 7055 105 7055 205 7055 115 7055 215 7056 105 7056 205 7056 115 7056 215 DO NOT REMOVE DO NOT REMOVE PROTECTIVE FILM PROTECTIVE FILM v FROM SENSOR EYE FROM SENSOR EYE x UNTIL INSTALLATION UNTIL INSTALLATION IS COMPLETE IS COMPLETE o o e a z 2 a n S ERAS n ee Aa ES ee S S 705P400 705P400 O 4 D O Q p a D 605XTMV AJLeA HUIXIN M965255 REV 1 6 Roughing in Dimensions Fig 1 m a 7 1 2 Oy OR BACKSPLASH MIN 1 CLEARANCE 140mm oy MOUNTING SURFACE 66mm 2 5 8 32mm 1 1 4 GENERAL DESCRIPTION Electronic faucet with proximity operation Vandal resistant solid brass construction single post mounting Operates on DC battery or AC power Inlets 3 8 compression built in checks flexible stainless steel 18 reach inlet hoses for spout connection and In line integral strainer for solenoid
10. l LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten See Fig 2 in this section M965255 REV 1 6 CHANGE HOT LIMIT SETTING FROM 95 TO 85 Fig 13 1 Remove the FAUCET COVER 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET COVER SCREW 4 at the back of the FAUCET Pull FAUCET COVER 1 up and off See Fig 2 in this section 2 Replace LEVER HANDLE and rotate counter clockwise to its stop position 100 cold Remove HANDLE 3 Pull out LIMITER STOP 1 from the VALVE STEM 2 4 Rotate LIMITER STOP 1 180 degrees and insert back onto VALVE STEM 2 5 Replace FAUCET COVER 1 and LEVER HANDLE 3 Install LEVER HANDLE SCREW 2 FAUCET COVER SCREW 4 and tighten See Fig 2 in this section HB GENERAL CLEANING Fig 14 1 For general cleaning use a damp soft cloth to clean the spout and the sensor 2 For cleaning dirt use a soft cloth with diluted dish washing detergent Wipe the area using a wet cloth and dry using a soft cloth Do not scratch the sensor when cleaning Avoid using anything that may scratch the spout surface Never use polishing power detergent or a nylon scrub brush They will damage the surface of the spout or Sensor How will know if battery needs to be replaced Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days Why has the flow rate of the faucet reduced significantly
Download Pdf Manuals
Related Search
Related Contents
Twinkle - Phenix Research Products Consultez le programme ici - Le Labo de l`économie sociale et Samsung GT-E1252/H User Manual Quick Use Guide Thermaltake MAX-1542 Karcher K205 User's Manual Full screen - Red de Revistas Científicas de América Latina y el AMB-289 PRECAUCIONES DE SEGURIDAD (ESPANOL) KDC-PS907 User guide Conference phone Konftel 200 Copyright © All rights reserved.