Home

American Standard Hampton 7222.702 User's Manual

image

Contents

1. into HANDLE q BASE 2 in a way that the male HANDLE BASE 9 square on the ADAPTER 1 fits in ihe female square of Eu i W Push HANDLE S and ADAPTER 1 HANDLE BASE 2 IS onto VALVE STEM 3 e M Eoy t 2 Orta 3 m Push out ADAPTER 4 carefully Push CROSS HANDLE 4 5 ont i HANDLE BASE 2 EIC W Turn ADAPTER 1 either 45 or 90 so that male square on y ADAPTER 1 catches different Install HANDLE SCREW 6 and tighten female square in HANDLE BASE 9 FUER INDEX CAE 7 8 in top of m Assemble and tighten HANDLE SCREW 6 i E Push INDEX CAP 7 in top of HANDLE 9 TEST INSTALLED FAUCET E Operate both HANDLES to flush water lines thoroughly Turn HANDLES into off position W Check SHOWER HEAD and SPOUT connections for leaks Operate Turn on water supplies and check all connections for leaks DIVERTER for proper operation Turn handles into OFF position SERVICE SPRING CLIP CARE To change direction of handle rotation proceed as follows S DO SINIPLY RINSE THE PRODUCT CLEAN Turn valve to OFF position WITH CLEAR WATER DRY WITH A SOFT Pull out INDEX CAP and remove HANDLE SCREW V COTTON FLANNEL CLOTH m Pull out LEVER BALL from HANDLE BASE m Unscrew HANDLE BASE and remove ADAPTER i EY lt DO NOT DO NOT CLEAN THE PRODUCT m Remove SPRING CLIP H WITH SOAPS ACID POLISH ABRASIVES dr SPRING IP 9O and replace HARSH CLEANERS OR A CLOTH WITH A m Reinstall HANDLE Se
2. 002 US60406REV 1 1
3. IPE 8 ELBOW 10 and roughing in NIPPLE 9 Connect to BOTTOM outlet of VALVE BODY 1 Add cross braces to wall structure and secure piping Cap NIPPLES 9 amp 5 and open supply lines and check for leaks Remove PLASTER GUARDS 2 Use spline on end of PLASTER GUARD 2 to open both VALVES and check for leaks Close both valves and turn off water supplies Replace PLASTER GUARDS 2 Finish wall construction 2 1 13 16 DIA HOLES FOR VALVES ON 8 CENTERS 1 1 13 16 DIA HOLE FOR CENTER TRANSFER VALVE 74 FOR HEAD CLEARANCE TYP UNION INLET 1 2 14 N P T 18 OPTIONAL p 4 Recommended Tools Phillips Screwdriver Plumbers a or Caulking DA TOP OF TUB RIM BOTTOM OF TUB i Flat Blade Screwdriver Adjustable Wrench PLASTER GUARD C SWIVEL L 7 COUPLING NUT Channel Locks Hex key ww with Fitting INSTALL TRIM SHOWER AND TUB SPOUT j ED NOTE PROTECT FINISH ON SHOWER AND TUB TRIM WHEN INSTALLING 2 Remove PLASTER GUARDS 1 from valve body by unthreading and pulling off Remove rough in nipple from shower elbow 9 SQ ROUGH IN Apply sealing tape to threads on both ends of SHOWER ARM 2 and install NIPPLE SHOWER ARM 2 with SHOWER ESCUTCHEON 3 into shower elbow Thread SHOWER HEAD 4 onto end of SHOWER ARM 2 Push SHOWER ESCUTCHEON 3 against fi
4. Yimniritau Sfaudard HAMPTON TWO HANDLE BATH SHOWER SET Installation Instructions 7220 702 7220 712 7220 722 7220 732 7221 702 7221 712 7221 722 7221 732 7222 702 7222 712 7222 722 7222 732 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin ROUGHING IN DIMENSIONS NOTE NO CONCEALED PIPING FURNISHED 1 1 4 DIA HOLE 1 2 N PT SHOWER ARM E r Certified to comply with ANSI A112 18 1M U S Patent No 5 819 789 US60406 REV 1 1 ROUGHING IN SHOWER AND SPOUT Turn off hot and cold water supplies before beginning CAUTION IMPORTANT DO NOT REMOVE PLASTER GUARDS 2 UNTIL STEP 2 FINISHED WALL Prepare water supplies per Roughing in Dimensions Apply sealing tape to all threaded connections Install VALVE 1 at indicated height and depth Make sure the outlet marked Le E OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65 AND 78 2 MIN 3 1 4 MAX 1 2 N PT TO SHR is pointing upward Mount VALVE 1 to cross brace with wood screws Slip COUPLING NUT over supply pipe and thread UNION SWIVEL to pipe Connect HOT 6 water supply to LEFT valve inlet and COLD 7 water supply to RIGHT valve inlet Prepare SHOWER RISER 4 and ELBOW 3 Connect to TOP outlet marked SHR of VALVE BODY 1 Prepare TUB FILLER P
5. e step three COARSE SURFACE If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 US60406REV 1 1 Americam Standard HAMPTON TWO HANDLE BATH SHOWER 060351 YYYOA SHOWER ARM AND FLANGE M953569 YYYOA SHOWER HEAD 013307 YYYOA METAL CROSS HANDLE 021470 YYYOA INDEX CAP AN 918428 0070A HANDLE SCREW HANDLE ioie 97 042692 0070A PORCELAIN CROSS HANDLE 916503 YYYOA LEVER HANDLE BASE 021470 YYYOA INDEX CAP E D S 918428 0070A HANDLE SCREW 0060353 YYYOA PORCELAIN LEVER HANDLE 060409 YYYOA DIVERTER SPOUT SLIP ON 7220 702 7220 712 7220 722 7220 732 7221 702 7221 712 908501 YYYOA BASE CROSS 994053 0070A CARTRIDGE 060453 YYYOA ESCUTCHEON KIT 923002 0070A ADAPTER 060354 YYYOA METAL LEVER HANDLE MODEL NUMBERS 7221 722 7221 732 7222 702 7222 712 7222 722 7222 732 M962341 0070A GROUND JOINT INLET Replace the YYY with 021470 YYYOA END CAP 907520 YYYOA P e HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 12 00 Product names listed herein are trademarks of American Standard Inc American Standard Inc 1999 SPOUT ESCUTCHEON appropriate finish code CHROME
6. nished wall Tighten SET SCREW 5 A Remove pipe cap from tub filler pipe Prepare TUB FILLER PIPE ELBOW and 1 2 C W T SPOUT NIPPLE Final length of SPOUT NIPPLE to be 1 from finished wall Push SPOUT ESCUTCHEON 6 onto filler pipe flush against finished wall ze Push TUB SPOUT 7 onto filler pipe until tight against SPOUT ESCUTCHEON 6 Tighten clamp screw in SPOUT 7 to secure TUB SPOUT 7 to rough in nipple PIPE CAP a SCREW 3 FINISHING INSTALLATION SHALLOW ROUGH IN DEEP ROUGH IN E Remove caps from roughing in nipples MORE THAN 9 1 2 B HAN E Remove PLASTER GUARD by turning counter clockwise and pulling SLEEVE E If VALVE BODY is roughed in SHALLOW more than 2 1 2 age SLEEVE screw SLEEVE in ESCUTCHEON facing front of ESCUTCHEON a 1 U W If VALVE BODY is roughed in DEEP less than2 1 2 screw SLEEVE in ESCUTCHEON facing back of ESCUTCHEON l E Assemble RUBBER RING to ESCUTCHEON L RUBBER n W Screw ESCUTCHEON and SLEEVE onto VALVE COVER against wall RING VALVE E BODY ESCUTCHEON E Install SHOWER ARM SHOWER ARM FLANGE and TUB SPOUT 4 INSTALL HANDLES FOR LEVER HANDLES Wi Turn VALVE into OFF position FOR CROSS HANDLES BW Push ADAPTER 1 into HANDLE BASE 9 ti in a way that the male square on the Turn VALVE into OFF position d ADAPTER 1 fits in he female square of the Push ADAPTER 1

Download Pdf Manuals

image

Related Search

Related Contents

SANYO DENTETSU SA NY O DE NT ET SU SANYO DENTET  User Manual  Série OREGON - Sportshop.fr  1 - Brother  Manual here  Situation 1 > Dans un bureau de banque    Eglo 89441A Installation Guide  TERMIBLOC MSF1  Sony MDS-PC2 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file