Home

American Standard Colony Soft 2175.502 User's Manual

image

Contents

1. making sure the guide teeth are facing O e outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J f LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing C outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M9688811
2. 3 E Clean CARTRIDGE INLETS and MANIFOLD MANIFOLD m Reassemble CARTRIDGE 3 alternately tightening SCREWS 4 CAR TARGE NERS Replace CAP 2 and HANDLE 1 Check flow 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M9688811 SpeedConnect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connectio
3. from drain body Fig A E Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE OF From under side of SINK E Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up SEL Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A m POP UP KNOB 1 must be fully down Fig B WHITE FOAM GASKET DRAIN NOT VISIBLE FLANGE M968881 r ATTACH CABLE CONNECTOR E Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE
4. Installation Instructions COLONY SOFT 2175 502 Single Control Lavatory Faucet with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with SpeedConnect drain a feature found only on American Standard faucets Certified to comply with ANSI A112 18 1 SpeedConnect Drain M968881 e Fewer parts installs in less time e Never needs adjustment Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the SpeedConnect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin i _ ON Al p E 0 Screwdriver Channel Locks Adjustable Wrench Plumbers Putty or Caulking Tubing Cutter INSTALL FAUCET BRUT nn before beginning Apply a bead of putty along the edge of the underside of the FAUCET 1 Insert FAUCET 1 and CABLE CONNECTOR 2 through center hole of mounting surface Fig A From under side of mounting surface thread the two MOUNTING NUTS 2 onto FAUCET SHANKS 4 Fig B Center FAUCET 1 and hand tighten MOUNTING NUTS 3 to secure FAUCET 1 HAND TIGHTEN 2 POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B y 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2
5. SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D tailpiece on POP UP DRAIN to 1 2 PIPE k waste outlet THREAD oy COUPLING 2 NUT FLEXIBLE SUPPLIES 3 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION CONNECTION COMPRESSION NUT FERRULE M9S68881 1 0 TEST INSTALLED FITTING m With HANDLE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m Ensure that AERATOR 3 is tightened completely Operate HANDLE 1 to allow water flow CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions ME VY Release POP UP KNOB 4 down and check all drain connections and P trap for leaks Tighten if necessary AA oS EEDD DC SERVICE If Faucet Drips Proceed As Follows Turn VALVE in OFF position m f faucet drips operate handle several times from off to on Do not apply excessive force E Clogged CARTRIDGE INLETS may cause reduced flow in full on hot or cold To clean inlets first turn off water supply then m Remove HANDLE 1 CAP 2 and CARTRIDGE
6. n 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A Fig B Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F REMOVE CAM CAP MS68881 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary dll to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re install the Cam Cap