Home

American Standard 2740.XXX User's Manual

image

Contents

1. 188 Kgs Sq m warranty Do not handle or move the whirlpool by the pump PROJECTED AREA motor or piping system A O aes Fittings bath filler shower arm etc are not provided with the WHIRLPOOL ELECTRICAL SPECIFICATIONS bath and must be ordered separately Framing and enclosing SYSTEM PUMP 1 1 HP 9 9 AMPS 120V materials are provided by others IMPORTANT GENERAL INSTALLATION INFORMATION Water test unit before installation and enclosure Bath may only be installed in a recess type installation Locate studs as required Insure rough dimensions are proper plumb and square For whirlpools access to pump motor may be made through access opening in apron panel The following procedure must be used for all installations leveling support stringer should be as indicated This bath is not self supporting and must be supported along it s entire bottom Support with mortar or grout Position bathtub whirlpool within the recess check level front to back side to side and shim as necessary To secure the tub to wood studs use drywall screws w washers or roofing nails immediately above the flange of the tub To secure the tub to steel studs use 4 drywall screws and flatwashers See page 2 for complete installation information Caution Take extra care when driving nails or screws to avoid damaging the tub The tile or similar finished floor will be butted against the bottom of the tub apron also holding the tub in place FOR AFTER SALES S
2. Putty USUALLY BETWEEN RETENTION VALVES e Pipe Wrench e Caulking waterproof 65 amp 78 FLANGE ry Sli J A t Pli e 1 3 2 2 1651 amp 1981mm 3 SIDES 12 C L OF Ip Join lers X or Xx OVERFLOW ee E LEVELING e Screw Driver Stringers com mune _ STRINGER e Standard Drop Cloth eres ot K FLANGE SUPPORT Woodworking Tools e 15 amp GFI TOROF t EN N NDER IDE Personal Safety Outlet DECK so t So OFBeck Equipment e Cement Plaster ene 483mm e Caulking Gun Grout 3 3 4 GENERAL INSTALLATION INFORMATION 95mm BATH SUPPORT 64mm MATERIAL Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor GENERAL SPECIFICATIONS FOR 2740 WHIRLPOOL immediately INSTALLED SIZE _____ 59 7 8 x 29 7 8 x 19 1 4 1521 x 759 x 489mm After inspection and during installation protect the bath from WEIGHT 105 Lbs 47 Kgs construction damage Before installation and before WEIGHT w WATER 480 Lbs 216 Kgs enclosing with wallboard tile etc water test the unit and GAL TO OVERFLOW____ 45 Gaal 171 L check for leaks eae a ee S capa ae If a whirlpool do not make modifications to the whirlpool system BATHING WELL AT RIM 25 1 2 x 55 1 2 648 x 1410mm or remove pump from factory mounting This could adversely WATER DEPTH TO OVERFLOW ___ 1 1 2 292mm affect the safety and performance of the whirlpool and void the FLOOR LOADING 39 Lbs Sq Ft
3. a liquid wax e Do not wax areas where you walk or stand e Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface e Clean the surrounding surface immediately after using caustic drain cleaners e Burning cigarettes will damage the surface e Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details 752562 100 Rev H 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
4. COLONY 5 x 30 AFR Americam Standard INTEGRAL APRONWTH ane 2 40 XXX SERIES Style That Works Better SFOR ABOVE OO i WHIRLPOOL BATHING POOL MA eA nines INSTALLATION INSTRUCTIONS 59 7 8 gt THANK YOU 3 Meet Winen for selecting an American Standard bath Your new bath is shipped 178mm RETENTION to you after careful inspection The whirlpool version is completely CIL OF DRAIN 34 n a GSibes assembled with pump motor and system piping All you need to FNIS finish the installation are your selected fittings and electrical SEE FITTING WALL Ss Ss connections for a whirlpool SPECS FOR gt 14 1 8 To insure maximum performance and pleasure from this product DIMENSIONS i D 359mm please follow the instructions and cautions TAILPIECE 7 29 7 8 759mm ON OFF j swit List of Required Components not included C L OF SS 5 D a spoor oF a p if Pume g Drain 1583 470 Bath Filler so Oo zgi see your American Standard Distributor HORIZONTAL TAILPIECE S lt lt 1 AIR VALVE T ACCESS TO PUMP MOTOR ABOVE FLOOR OUTLET 6 JETS THROUGH REMOVABLE 1 1 2 38mm lt FRONT ACCESS PANEL 4 m List of Required Tools and Supplies C L OF f SHOWER ARM Tools Supplies De e Level e Nails FINISHED FLOOR 7 8 WATER GIL OF Tape Measure
5. ERVICE CALL 1 800 442 1902 WEEKDAYS AS America Inc 2008 752562 100 Rev H All product names listed herein are trademarks of AS America Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS Locate studs as required Ensure roughing in dimensions are proper plumb and square Access to Pump Motor may be made through the access opening in the apron panel It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron may be used as the primary access opening 1 As shown in Fig 1 mark the position of the underside of the deck by tracing a line onto the studs at the height indicated using a level or other suitable straight edge 2 With the top of the stringer touching the traced line attach the stringer to the studs Install drain components to the whirlpool or bath following the manufacturers instructions 4 THIS BATH MUST BE SUPPORTED ALONG ITS ENTIRE BOTTOM We recommend the use of mortar as bedding material sand is not recommended Apply enough bedding to support the complete bottom of the bath After the bedding has been poured and before it sets position whirlpool or bath within recess until the rim is leveled against the leveling stringers see Typical Recess Installation shown below The rim of the bath MUST NOT support weight Allow the bedding material to completey harden before applying weight to the rim or bottom of the bath Any finish mat
6. TALLATION SEPERATE 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752562 100 Rev H 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this Motor High chart are recommendations Performance for copper conductors Rating only Always follow 115V Power Line local and national 1 1 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixe
7. d with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance AFTERCARE and CLEANING e Always fill the tub with temperate water Excessively hot water may cause surface damage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove stains cigarette tar deposits or other surface blemishes e Abrasive cleaners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with
8. erial such as tile or wall board must be self supporting if it contacts the deck of the bath FIG 1 SUGGESTED WHIRLPOOL BATH INSTALLATION METHOD Stud Wood or Steel Waterproof Dry Wall or Cement Board Finished Wall Sealant TYPICAL RECESS INSTALLATION Tub Leveling Stringer 1x 3 25 x 76mm WOOD SECURE THE BATH TO THE STUDS AS SHOWN FOR wot WOOD OR STEEL STUD CONSTRUCTION yn LEVELING Oe 752562 100 Rev H 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ELECTRICAL INS