Home

American Power Conversion CTEG4M User's Manual

image

Contents

1. 30 red black 48 black gt 25 PF Pod g 28 black 45 red black i 67 Pas Pra Pas 45 red Chapter 3 Service Contact and Warranty Information Service APC makes every effort to ensure parts and equipment arrive in working condition Occasionally it may be necessary to return parts or equipment that are not in working condition If the UPS requires service do not return it to the dealer Instead follow these steps 1 Contact APC Customer Service through the APC web site www apc com support Note the product model number the serial number and the date purchased If you call APC Customer Service a technician will ask you to describe the problem and try to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA Ifthe product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Refer to the APC web site Select the appropriate country from the country selection field Select Support from the tab at the top of the web page 2 Pack the product in its original packaging If the original packing is not available refer to the APC web site for information on obtaining appropriate packing materials m Pack the unit properly to avoid damage in transit Never use Styrofoam beads for pack
2. Ltd 339 Suhong Zhong Lu Suzhou Industrial Park Suzhou Jiangsu 215021 PRChina Importer s Name and Address American Power Conversion A P C b v Ballybritt Business Park Galway Ireland Place N Billerica MA U S A Richard J Everett Sr Regulatory Compliance Engineer 6 02 Place Galway Ireland Ray S Ballard Managing Director Europe phan 5Jan02 Entire contents copyright 2002 by American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC is a registered trademark of American Power Conversion Corporation All other trademarks are the property of their respective owners 10
3. upon receipt Notify the carrier if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the package contents The package contains the enclosure battery cables associated hardware and product documentation CTEG4M 9 cables 15 black battery jumpers 3 28 black 1 48 black 1 15 red 1 29 red 2 30 red 1 CTEG4M8M 12 cables 15 black battery jumpers 4 26 black 1 27 black 1 28 black 1 56 black 1 15 red 1 25 red 1 34 red 1 35 red 1 CTEG4M12B 17 cables 15 black battery jumpers 9 30 black 2 80 black 1 18 red 1 30 red 2 45 red 2 CTEG4M when wired with 15 black battery jumpers 3 28 black 1 48 black 1 the CTEG12B 8 cables 19 red 1 29 red 45 red 1 CTEG4M Front View CTEG4M Rear View Generator Control Module Power Supply Module Shelf Crank Battery Coaxial Battery T Bue ae Outputs CTEG4M8M Front View CTEG4M8M Rear View Generator Interface Power Supply Module Shelf CTEG4M12B Front View CTEG4M12B Rear View Battery Breaker 4 Panel g Installing the CTEG Enclosure 1 Install an APC approved concrete pad Contact APC for more information 2 Place the enclosure on the pad The holes on the enclosure must be aligned with the anchor hooks on the pad 3 Secure the enclosure to the
4. APC BroadBand CTEG4M Series www apc com Power Supply and Battery Enclosures User s Manual 990 5521 07 02 Chapter 1 General Information The CTEG4M Series Enclosures provide power source housing for broadband cable operations Safety This Safety Guide contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries It is intended for APC customers who setup install relocate or maintain APC equipment Changes and modifications to this unit not expressly approved by APC could void the warranty Failure to observe these warnings may result in serious injury death or damage to the equipment Electrical Do not work alone under hazardous conditions Warnings Do not handle any metallic connector before the power has been disconnected Servicing this equipment may require working with protective covers removed and utility power connected Use extreme caution during these procedures High current through conductive materials could cause severe burns When grounding cannot be verified disconnect the equipment from the utility power outlet before installing or connecting to other equipment Reconnect the power cord only after all connections are made Check that the power cord s plug s and sockets are in good condition Replacement of fuses or other parts must be with identical types and ratings Substitution of nonidentical parts may cause safety and fire haza
5. RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Regulatory Approval 6 CE Declaration of Conformity We the undersigned declare under our sole responsibility that the equipment specified below conforms to the following standards and directives Standards to Which Conformity Declared EN 60950 Application of Council Directives 73 23 EEC Type of Equipment Power Supply Model Numbers CTEG4M CTEG4M8M CTEG12B Manufacturer s Name and Address American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA American Power Conversion A P C b v Ballybritt Business Park Galway Ireland or American Power Conversion 2nd Street PEZA Cayite Economic Zone sario Cavite Philippines or American Power Conversion Main Avenue Peza Rosario Cavite Philippines 5 APC Suzhou UPS Co
6. aging Damage sustained in transit is not covered under warranty 3 Mark the RMA on the outside of the package 4 Return the unit by insured prepaid carrier to the address given to you by Customer Service How to Contact APC In the USA Outside the USA Refer to the APC web site Refer to the APC web site www apc com Select the appropriate Wwww apc com support country from the country selection field Select the Support tab at the top of the web page Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WAR
7. en wiring and connecting the batteries Tape one end of each jumper cable prior to installation 2 o XY N Be sure to deliver spent batteries to a recycling facility or ship to the 69 ing materi 9 manufacturer in the replacement battery packing material CTEG4M Bottom Shelf Cable to CTSP 2 28 black Cable to CTSP 1 48 black Cable to CTSP 1 29 red Battery Circuit Breaker 1 Cable to CTSP 2 29 red Battery Circuit Breaker 2 Top Shelf CTSP 1 Battery Connection CTSP 2 Battery Connection Cables from Battery 1 and Circuit Breaker 1 on Bottom Shelf Cables from Battery 1 and Circuit Breaker 2 on Bottom Shelf CTEG4M8M REAR Cable to Battery 6 Bottom Shelf 28 black 26 black Center Partition Cables to CTSP T helf on Top She Cable from Battery 8 56 black to CTSP 34 red to CTSP REAR Top Shelf 28 black 27 black Center Partition p 35 red CTSP Battery Connection Cables from Battery 1 and Circuit Breaker on Bottom Shelf Cable from Circuit Breaker CTEG4M12B EG4M EG4M12B 80 black gt red
8. pad Wiring Grounding 1 Install and interconnect ground rods appropriate for proper grounding according to local electrical code requirements 2 Route ground wires from the ground system into the bus bar located inside the enclosure 3 Attach the ground wires to the common ground bus bar Input Wiring 1 Verify that the input utility circuit breaker located on the side of the enclosure is in the OFF position 2 Route the utility input line through the conduit and into the enclosure 3 Connect the utility main lines L1 and L2 red and black to the enclosure entrance terminals 1 and L2 Ensure that sufficient service loops are available 4 Connect the utility neutral line to the enclosure neutral bus strip 5 Verify that the utility ground is connected to the enclosure bus strip 6 For three wire input connect a separate 12 AWG wire from the neutral bus strip to the ground bus strip Output Wiring 1 Install a pin connector not furnished to each of the output cables 2 Attach the wires from the output terminal blocks to the pin on each cable 3 Attach the ground wires to the cables Installing the Power Supply Refer to the installation instructions included with the power supply components for details Options Contact APC for information on available options Connecting the Batteries The battery circuit breaker must be in the OFF position prior to battery installation Use normal precautionary measures wh
9. rds Overhead Never stand below anything while it is hoisted Always wear a hard hat Warnings Lifting Transformer modules are heavy Use proper lifting techniques and equipment Warnings to avoid injury Battery Danger of explosion if battery is incorrectly connected or replaced Replace Warnings batteries only with same or equivalent type recommended by the manufacturer Specifications Environmental Specifications Operating Temperature 40 F to 140 F 40 C to 70 C Humidity 5 to 95 noncondensing within enclosure Physical Specifications Characteristic Specification Height 31 79 cm Width 35 89 cm Depth 25 64 cm Weight CTEG4M 120 lbs 54 kg CTEG8M 12B 85 Ibs 39 kg Chapter 2 Installation and Maintenance Only trained service personnel should install and maintain the Power Supply Prior to installing the enclosure AC line voltage must be routed to the installation site Local state federal and or National Electric Code NEC regulations regarding location permits and electrical wiring must be adhered to Do not operate the Power Supply where the temperature and humidity are outside the specified limits See Specifications in this manual Models Supported CTEG4M Encl TSP 2 4 Batteries Generator Control Module CTEG4M8M Encl TSP 1 8 Batteries Generator Interface CTEG4M12B Encl 12 Batteries Unpacking Inspect the unit