1. DED If you must use an extension cord use only extension cords that are intended for outdoor use Use only extension cords having an electrical rating not less than the rating of the product 2 Examine extension cord before use DO NOT USE DAMAGED EXTENSION CORDS 3 Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord 4 WARNING to reduce the risk of electrocution keep all connections dry and off the ground Do not touch the plug with wet hands Assembly Instructions 1 After opening the carton please remove all parts and check against photograph on carton If any parts are missing please call Alltrade at 1 800 423 3598 2 Close the drain valve on the bottom of the air tank by turning the valve clockwise until fully closed 3 Attach the air hose to the compressor regulator valve Use included Teflon thread sealing tape on the threads to make sure you have an airtight connection Do not overtighten fittings 4 Attach the desired accessory to the end of the hose Use included Teflon thread sealing tape on the threads to make sure you have an airtight connection Do not overtighten fittings WARNING READ AND UNDERSTAND ALL PRODUCT FEATURES PRIOR TO OPERATING COMPRESSOR Product Features 1 AUTOMATIC ON OFF PRESSURE SWITCH This compressor is equipped with an automatic on off pressure switch The compressor will only run when the switch is in the I ON position O
2. FOR CUSTOMER SERVICE PARA EL SERVICIO PARA EL CONSUMIDOR 1 130 522 9008 ALLTRADE ALLTRADE TOOLS LLC 1431 VIA PLATA LONG BEACH CA 90810 1462 www alltradetools com MADE IN HECHO EN CHINA COPYRIGHT 2006 ALLTRADE TOOLS LLC REV 1 Model 835579 T RA D E S Modelo 835579 PR Air Compressor Compresor de Hire Please retain these instructions for future reference If you encounter any problems or difficulties please contact our Customer Service Department at 1 310 522 9008 Por favor guarde estas instrucciones para que le sirvan de referencia en el futuro Si usted se encuentra con alg n problema o dificultad por favor comun quese con nuestro Departamento de Servicios para el Consumidor 1 310 522 9008 2 GALLON AIR COMPRESSOR e NEVER move the unit by pulling on the air hose Use the handle provided on the top of the unit e DO NOT reach over or across running machines e To reduce the risk of injury close supervision is necessary when the compressor is used near children e DO NOT ALLOW CHILDREN TO OPERATE THE COMPRESSOR AT ANY TIME DO NOT MAKE ANY MODIFICATIONS TO ANY OF THE COMPONENTS Units with broken or missing parts or without protective housings or covers in place should NEVER be operated e Do not leave the compressor unattended while the power switch is in the I ON position When the power switch is in the I ON position pump motor may start at any time without warning e Do
3. nce the tank has reached the desired preset pressure see Operating Instructions the pump motor will automatically shut off While the switch is in the I ON position the pump motor will automatically turn back on once the pressure in the tank drops below the minimum preset pressure Do not leave the compressor unattended while the power switch is in the I ON position 2 REGULATOR The regulator allows you to select the amount of air pressure that is output through the air hose into tools and accessories Please refer to the air delivery requirements of your tools for the proper pressure settings 3 TANK PRESSURE GAUGE The tank pressure gauge provides a reading of the air pressure inside of the compressor tank 4 SAFETY VALVE This compressor is equipped with a safety valve switch that will engage when the pressure in the tank exceeds the maximum rated pressure DO NOT attempt to modify or remove safety valve 5 TANK DRAIN FITTING Water is produced whenever air is compressed It is critical to drain water from the air tank on this compressor frequently If unit is used only occasionally tank should be drained after each use and prior to the next use To drain the tank slowly open the tank drain fitting by turning clockwise Once all water has drained out close the fitting securely NOTE tank will not pressurize while fitting is open 6 THERMAL SHUTDOWN SWITCH The electric motor is equipped with an automatic the
4. not overpressurize tank e If compressor has been dropped or impacted in any manner check tank for cracks before using e Never attempt to fill or operate compressor if any air leak is detected e Do not modify or attempt to service tank e Do not store liquids in tank This product is not intended for use as a portable breathing device or to disperse any type of liquid e Maximum pressure 100 PSI Grounding Instructions 1 This product shall be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock 2 This product is equipped with a cord having a grounding wire with an appropriate grounding plug 3 me plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper installation of the grounding plug can result in a risk of electric shock If repair or replacement of the cord is necessary do not connect the grounding wire to either flat blade terminal The wire with green insulation with or without yellow stripes is the grounding wire 4 Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician Extension Cord 1 Use of an extension cord with this product is NOT RECOMMEN
5. on system so no lubrication is needed 2 Periodically drain tank of excess moisture Excess moisture in the tank will result in wear and tear on tools and accessories 3 Fuse Replacement Disconnect power cord from electrical outlet prior to fuse replacement Replace with 5A 250V Glass Tube Fuse only lly Troubleshooting 1 The compressor will not run Probable cause 1 No power or the switch is in the OFF position 2 Motor overheated 3 Tank Pressure at maximum Solutions 1 Make sure the compressor is plugged in and the switch is in the ON position 2 Allow compressor to cool for 5 10 minutes until thermal overload switch resets 3 Release air from tank 2 Tank pressure drops when compressor shuts off Probable cause 1 Loose drain valve 2 Loose connection at regulator or pressure switch Solutions 1 Tighten drain valve 2 Check connections for leaks 3 Compressor runs continuously Probable cause 1 Excessive water in tank 2 Humidity too high Solutions 1 Decrease usage or increase size of compressor 2 Check all connections for leaks 4 Excessive starting and stopping Probable cause 1 Excessive water build up in tank Solutions 1 Drain tank through drain valve
6. rmal overload protector If the unit is overheating the motor will automatically shut down Turn the unit off and wait 5 10 minutes before turning the unit back to the ON position If the unit shuts down again please contact the manufacturer for assistance Operating Instructions START UP 1 Slowly open tank drain by turning clockwise Allow any water in tank to drain out Close fitting securely 2 Before connecting the compressor to the grounded outlet check for broken components and accessories and check for damage to the hose 3 Make sure the power switch is turned O OFF position 4 Plug the unit into a grounded outlet 5 Attach desired tool to the end of the air hose 6 Turn the switch on the I ON position 7 Adjust regulator knob to desired pressure level once the pump has shut off and the compressor has stopped running STORAGE 1 Disconnect unit from grounded outlet 2 Disconnect tools and or accessories from the air hose 3 Locate drain valve on bottom side of tank 4 Open drain valve to release remaining pressurized air and moisture from the air tank Moisture build up in the tank is normal with air compressors so a small amount of water may come out while draining the tank Draining the tank is vital for the longevity and safety of your air compressor 5 Close valve and store the compressor in a cool dry place MAINTENANCE 1 This compressor is supplied with a closed lubricati