Home
Air King BFQ50 User's Manual
Contents
1. Description Replaceme Description Replaceme 1 Fan Housing 5822050 1 otor BFQ110 5822050 2 Collar 5S22050 1 otor BF0140 5S22990 3 Damper 5522050 1 otor BFQ175 99229901 4 Polarized Nylon Receptacle 3P 9822050 Clip 9922 5 Wire Cover 5822050 Screw 5822 6 Screw 5822050 1 otor Bracket 5822 7 Motor BFO50 5522990 1 Blower Wheel 5822 Motor BFO70 5S22990 1 Grill 5922 Motor BFO75 5822990 Grill Springs 5922 Motor BFQ90 5822990 1 Snap In Bracket 9922 Installer Installation Date Place of Purchase Model Number 2A0572021 Rev C 6 06 WWW AIRKINGLIMITED COM 4of8 INSTRUCTIONS IMPORTANTES MANUEL D OPERATION e e E aa HinKing Ventilateur d vacuation Ventilation Products m8 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OPERER O DE R PARER LE PRODUIT D CRIT PROTEGEZ VOUS MEME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE SECURITE FAILLIR A SE CONFORMER AUX INSTRUCTIONS PEUT RESULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE A LA PROPRIETE CONSERVER CES INSTRUCTIONS POUR R F RENCES FUTURES INSTRUCTIONS G N RALES DE S CURIT Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lectrique et de blessures corporelles incluant ce qui suit 1 Bien lire toutes les instructions avant d installer ou d utiliser A
2. AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Nettoyage de la grille Retirer la grille et utiliser un d tergent doux tel que du liquide pour la vaisselle puis s cher l aide d un chiffon doux NE JAMAIS UTILISER D ABRASIF OU DE POUDRE R CURER S cher compl tement la grille avant de la r installer Pour r installer la grille vous r f rer la Section 6 Compl tion de l installation 2 Nettoyage de l assemblage du ventilateur D brancher le cordon du moteur de son r ceptacle Nettoyer toutes les pi ces avec un chiffon sec ou passer d licatement l aspirateur dans le ventilateur NE JAMAIS IMMERGER DES PI CES ELECTRIQUES DANS L EAU Rebrancher le cordon et remettre l alimentation Guide de d pannage Trouble Cause Possible 1 Le ventilateur ne fonctionne pas lorsque l interrupteur est la position en marche peut tre d cle nch La fiche de raccord du moteur n est pas connect e Un fusible peut tre grill ou un disjoncteur Le c blage n est pas raccord correctement Solution Sugg r e Remplacer le fusible ou r initialiser le disjoncteur Couper l alimentation l unit Retirer la grille et brancher le moteur dans le r ceptacle dans le cabinet Remettre l alimentation sur l unit Couper l alimentation de l unit V rifier que tous les fils sont raccord s 2 Le ventilateur fonctionne mais l
3. air circule plus lentement que la normale Obstruction dans les conduits d vacuation V rifier pour toute obstruction dans les conduits Les plus courantes sont des nids d oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue vers l ext rieur Le moteur est l che 3 Le ventilateur fonctionne de mani re plus bruyante que la normale de l unit 2A0572021 Rev C 6 06 L h lice du ventilateur frotte contre le cabinet Couper l alimentation l unit Retirer la grille et v rifier que toutes les vis sont compl tement serr es Remettre l alimentation sur l unit Appeler votre marchand pour un service WWW AIRKINGLIMITED COM 7 of 8 GARANTIE LIMITEE Tous les produits fabriqu s par Air King Limited sont garantis pour un an partir de la date d achat contre les d fauts de main d uvre et ou de mat riel De plus tous les ventilateurs vacuateurs chaufferettes combin s ventilateur lumi re et ou les chaufferettes et les hottes de cuisine sont garantis pour cing ann es partir de la date d achat contre les d fauts de main d uvre et ou de mat riel Cette garantie ne couvre pas de co ts de transport ou de main d uvre ou le co t de remplacement de composantes faisant partie d entretien de routine tels que Filtres graisse des hottes de cuisine filtres au charbon ou combin filtre graisse charbon ampoules lectriques de remplacement dans les hottes de cuisine
4. ou les combin s ventilateur lumi re chaufferette pour salle de bain Aussi tout dommage ou d faillance caus par un abus une mauvaise utilisation une installation fautive ou un entretien incorrect ne sera pas couvert par cette garantie De mani re effectuer une r clamation sous cette garantie vous devez tre l acheteur original du produit Il vous sera exig de pr senter la facture d achat originale Air King qui d montrera La date d achat l endroit de l achat et le mod le achet Le manquement rencontrer ces exigences annulera votre garantie Air King ne sera pas tenu responsable de quelque blessure corporelle ou dommage la propri t ou l immeuble que ce soit caus directement ou indirectement par le produit Certains Etats ne permettent pas de limitation sur la dur e de la garantie implicite ou l exclusion ou la limitation de dommages indirects ou accessoires ainsi ces limitations et exclusions peuvent ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir des droits qui varient d un Etat l autre et d une province l autre POUR DES PI CES OU DE L ASSISTANCE TECHNIQUE Veuillez appeler au 1 800 465 7300 DU LUNDI AU VENDREDI ENTRE 8 00 HRE ET 16 00 HRE HNE VEUILLEZ NE PAS RETOURNER CE PRODUIT A L ENDROIT DE L ACHAT D ORIGINE R f rencer le type et le style du produit localis sur l tiquette l int rieur du produit lorsque vous appel
5. 1 Hardware Bag 1 Electrical Connector 3 Wire Nuts 1 Instruction Safety Sheet 2 Remove the wire compartment cover and store in the carton until needed so it does not get damaged or lost Figure 1 3 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions 4 Select the most convenient electrical knockout and remove O using a straight blade screw driver 9 Figure 2 SECTION 2 Figure 2 New Construction 1 Using the gauge on the mounting bracket line up the bracket on the joist so the bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2A0572021 Rev C 6 06 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient Figure 4 SECTION 3 Existing Construction 1 Position housing against the joist or stud and trace an outline of the housing onto the ceiling wall material Set housing aside and cut opening being careful not to cut or damage any electrical or other hidden utilities Figure 5 2 Line up the bracket on the joist so the bottom of the fan will be flush with the finished ceiling Nail or
6. IMPORTANT INSTRUCTIONS OPERATING MANUAL Models BFQ50 BFQ70 BFQ75 BFQ90 BFQ110 BFQ140 BFQ175 e e Ventilation Products g READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following Read all instructions before installing or using exhaust fan Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors This unit must be grounded To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit fasten a prominent warning device such as a tag to the servi
7. Quincaillerie 1 Connecteur lectrique 3 Coinceurs Cables 1 Feuillet d instructions s curit Enlever le couvercle du compartiment c ble et le ranger dans l emballage jusqu ce que vous en ayez besoin afin qu il ne soit pas perdu ou endommag Figure 1 Choisir l emplacement pour votre ventilateur Pour assurer la meilleure performance d air et sonore il est recommand que la longueur de conduit et le nombre de coudes soient gard s au minimum et que du conduit rigide isol soit utilis Des conduits plus gros r duiront le bruit et les restrictions du d bit d air S lectionner l alv ole d fon able la O mieux appropri e et l enlever l aide D d un tournevis lame plate Figure 2 Figure 2 En utilisant le guide sur le support de montage aligner le support sur la solive pour que le dessous du ventilateur soit effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 Fixer par pression le b ti du ventilateur dans le support Figure 4 Le ventilateur peut tre fix par pression en position avec le collet de conduit faisant face gauche ou droite en fonction de quelle direction est la plus pratique Figure 4 SECTION 3 Construction Existante 1 N Positionner le cabinet contre la solive ou le montant et tracer le contour du cabinet sur le mat riau du mur plafond Mettre le cabinet de c t et d couper l ouverture e
8. VERTISSEMENT POUR USAGE DE VENTILATION le ventilateur d vacuation G N RALE EXCLUSIVEMENT NE PAS UTILISER POUR VACUER 2 Utiliser cette unit seulement de la mani re pour laquelle le DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES fabricant l a con u Si vous aviez des questions veuillez 6 Lors de coupe ou de per age des murs et plafonds ne pas contacter le fabricant se j endommager le filage lectrique et autres utilit s cach es 3 Avant d effectuer un service ou de nettoyer l unit couper a 7 Les ventilateurs avec conduits doivent toujours tre vacu s l alimentation lectrique dans le panneau de distribution et f a i D vers l ext rieur verrouiller le dispositif de d connexion afin d viter que l alimentation ne revienne accidentellement Lorsque le 8 Cette unit doit tre mise la terre dispositif ne peut tre verrouill fixer solidement un avis 9 Pour viter des dommages aux roulements des moteurs et ou d avertissement tel qu une tiquette au panneau de distribution des h lices bruyantes ou d s quilibr es emp cher la 4 Le travail d installation et le c blage lectrique doivent tre poussi re de cloison s che poussi re de construction etc effectu s par une des personne s qualifi e s en conformit d atteindre l unit de puissance e AVERTISSEMENT POUR R DUIRE LES RISQUES mi ore Le D INCENDIE OU DE CHOC LECTRIQUE NE PAS UTILISER CE 5 De l ai
9. bathroom fan light bulb heater combinations As well any damage or failure caused by abuse misuse abnormal usage faulty installation or improper maintenance will not be covered by this warranty In order to make a claim on this warranty you must be the original consumer of the product You will be required to present to Air King the original bill of sale showing date of purchase place of purchase and model purchased Failure to meet these requirements will void your warranty Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of the product when you call For more information please visit our website wwwairkinglimited com
10. ce panel WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK 4 Installation work and electrical wiring must be done by DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL qualified person s in accordance with all applicable codes DEVICE and standards including fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS 10 Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit 11 NEVER place a switch where it can be reached from a tub or shower WARNING DO NOT USE IN KITCHENS SAVE THESE INSTRUCTIONS 2A0572021 Rev C 6 06 WWW AIRKINGLIMITED COM 10f8 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Exhaust Fan 1 Unpack fan from the carton and confirm that all pieces are present In addition to the exhaust fan you should have 1 Grill 1 Damper Assembly attached 1 Mounting Bracket
11. ez Pour plus d information veuillez visiter le site Web de Air King au www airkinglimited com 6 Description Replaceme 6 Description Replaceme 1 Cabinet du ventilateur 582205 7 1 Moteur BF0110 582205 2 Collet 582205 1 Moteur BF0140 582299 3 Clapet 982205 1 Moteur BFQ175 552299 4 R ceptacle 3P Polaris en Nylon 582205 Clip 582205 5 Couvercle des cables 582205 Vis 58220501 6 Vis 982205 1 Support du Moteur 992299 7 Moteur BFO50 582299 1 Roue de la Soufflante 582299 Moteur BFO70 582299 1 Grille 582205 Moteur BFO75 582299 Ressorts de la grille 582205 Moteur BFO90 582299 1 Support Fixer par Pression 582205 Installateur Date d installation Endroit de l achat Num ro de mod le 2A0572021 Rev C 6 06 WWW AIRKINGLIMITED COM 8 of 8
12. he fan s receptacle Connect the ground wire from the house to the Green wire from the fan s receptacle Figure 7 Use approved methods for all connections SECTION 6 Completing the Installation 1 Reinstall the fan s wire compartment cover Rotate the blower wheel by hand to ensure it spins freely Plug the fan s quick connect motor cord into the receptacle This cord will only fit one way into the receptacle Figure 8 3 Install the grill by squeezing the two ends of the springs together and installing them up into the slots of the fan s housing Push the grill up into position Figure 9 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill Cleaning the Fan Assembly Unplug the motor cord from receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restore power Troubleshooting Guide Trouble Probable Cause 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped Suggested Remedy 1a Replace f
13. n prenant bien soin de ne pas couper ou endommager d utilit lectrique ou dissimul e Figure 5 Aligner le support sur la solive de mani re que le bas du ventilateur soit effleurement avec le plafond fini Clouer ou visser solidement le support fixer par pression en place Figure 3 Fixer par pression le b ti du ventilateur dans le support Figure 4 Le ventilateur peut tre fix par pression en position avec le collet de conduit faisant face gauche ou droite en fonction de quelle direction est la plus pratique SECTION 4 Conduits AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU BATIMENT LOCAUX ET NATIONAUX 1 Raccorder le conduit au collet de conduit du ventilateur Figure 6 Fixer en place l aide de ruban ou de serre joint Toujours vacuer le ventilateur vers l ext rieur au travers de chapeau mural ou de toit WWW AIRKINGLIMITED COM 6 of 8 SECTION 5 C blage AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Courir le filage d un interrupteur mural approuv de calibre appropri Un fil neutre blanc un fil de mise la terre
14. r en quantit suffisante est requis pour la bonne VENTILATEUR AVEC UN R GULATEUR DE VITESSE LECTRONIQUE combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour 10 Acceptable pour utilisation au dessus d une baignoire ou pr venir un refoulement Suivre les directives du fabricant d une douche lorsque install dans un circuit prot g par un de l quipement de chauffage et les normes de s curit telles disjoncteur de fuite de terre que celles publi es par la National Fire Protection Association 11 NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorit s locales du code AVERTISSEMENT NE PAS UTILISER DANS LES CUISINES NE JAMAIS placer un interrupteur un endroit qui puisse tre atteint de la baignoire ou de la douche CONSERVER CES INSTRUCTIONS 2A0572021 Rev C 6 06 WWW AIRKINGLIMITED COM 5of8 INSTRUCTIONS D INSTALLATION AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 SECTION 2 Nouvelle construction f 2A0572021 Rev C 6 06 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En plus du ventilateur d vacuation vous devriez avoir 1 Grille 1 Ensemble de clapet attach 1 Support de Montage 1 Sac de la
15. screw the snap in bracket in place securely Figure 3 3 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Connect the ducting to the fan s duct collar Figure 6 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap WWW AIRKINGLIMITED COM 2 of 8 SECTION 5 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Run wiring from an approved wall switch carrying the appropriate rating One neutral white one ground green or bare copper and one hot black lead connected to the switch Secure the electrical wires to the housing with an approved electrical connector Make sure you leave enough wiring in the box to make the connection to the fan s receptacle 2 From where you have access to inside the fan s junction box connect the White wire from the house to the White wire from the fan s receptacle Connect the Black wire from the wall switch to the Black wire from t
16. use or reset circuit breaker 1b Connector plug from motor is not plugged in 1b Turn off power to unit Remove Grill and plug motor into receptacle 1c Wiring is not connected properly in housing Restore power to unit 1c Turn off power to unit Check that all wires are connected 2 Fan is operating but air moves slower than normal 2 Obstruction in the exhaust ducting 2 Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Motor is loose 3a Turn off power to unit Remove grill and check that all screws are fully tightened Restore power to unit 3b Fan blade is hitting housing of unit 3b Call your dealer for service 2A0572021 Rev C 6 06 WWW AIRKINGLIMITED COM 3of8 LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and or material In addition all ventilating exhaust fans heaters combination fan lights and or heaters and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and or material This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as range hood grease filters charcoal filters or combination charcoal grease filters replacement light bulbs in range hoods or
17. vert ou cuivre d nud et un fil vivant fil noir connect l interrupteur Fixer les fils lectriques au cabinet l aide d un connecteur lectrique approuv Assurez vous de laisser suffisamment de fil dans la boite de raccord pour la connexion au r ceptacle du ventilateur 2 De l o vous avez acc s l int rieur de la boite de jonction du ventilateur connecter le fil Blanc provenant de la r sidence au fil Blanc du r ceptacle du ventilateur Connecter le fil Noir de l interrupteur mural au fil Noir du r ceptacle du ventilateur Connecter le fil de mise la terre provenant de la r sidence au fil Vert du r ceptacle du ventilateur Figure 7 Utiliser des m thodes approuv es pour toutes les connexions Alimentation provenant de la r sidence a Q N SECTION 6 Compl tion de l installation 1 R installer le couvercle du compartiment de c ble du ventilateur en place Faire tourner la roue de la soufflante la main pour vous assurer qu elle tourne librement Brancher le cordon raccordement rapide dans le r ceptacle Ce cordon ne s ajuste que d une seule fa on dans le r ceptacle Figure 8 2 Installer la grille en pressant ensemble les deux extr mit s des ressorts et en les installant dans les fentes du ch ssis du ventilateur Pousser la grille en position Figure 9 3 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien