1. PPH Type F 4 M 2 Wall or Ceiling Stud GENERAL SAFETY INFORMATION 19 2090547 Contratuerca 3 1 Make certain that the power source conforms to the electrical require ments of the Fan Lag Shield 21 2070027 Ojo de Buey 1 2 The power cord is equipped with a three prong grounded plug that must Masonary Only Fat Washers be inserted into a matching receptacle Under no circumstances must the grounding prong be cut off the plug Where a two prong wall receptacle Lag Screw 23 Grapa de Cable 2 is encountered it must be replaced with a properly grounded three prong receptacle installed in accordance with the National Electrical Code Em NEC and all applicable local codes and ordinances This work must be Suministros por Bolso de Piezas Componentes F sicas 2098012 done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION USE OF SUCH ADAPTERS ARE NOT Figure 1 PERMITTED IN CANADA Rev F 4 01 4 2084576 Rev F 4 01 1 2084576 MODEL 4YN46C 9318C CAUTION THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY SECONDARY SUPPORT CABLE 1 Loop one end of Cable around the Large Diameter Wires of both the Front and Rear Circulator Guard Figure 2 2 Attach a Cable Clamp with the U on the tail side of the loop leaving a tail approximately 1
2. FUTURE REFERENCE DESCRIPTION The AirKing 18 45 7 cm Multi Mount Fan features Pull Cord operation and a 3 paddle Fan Blade This Fan has a permanently lubricated motor with a 9 ft 2 74 m 18 3 cord set and are constructed of sturdy powder 3 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed and of the proper gage and length Never use a single extension cord to operate more than one Fan 4 Do not insert fingers or foreign objects into the Fan Do not block or tamper with the Fan in any manner while itis in operation Do not touch the Fan while in operation or just after it has been turned off as some parts may be hot enough to cause injury 5 Unplug power cord before installing or servicing the Fan WARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This Fan is intended for general use ONLY It must NOT be used in potentially dangerous locations such as flammable explosive chemi cal laden or wet atmospheres WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE REF NO NO DE PARTE 7 Be sure Fan is on a stable surface when operating to avoid chance of coated steel it overturning DESCRIPCI N CANT 1 2065510 Placa
3. Hz 18 45 7 cm Tama o de paletas 18 45 7 cm Modelo 4YN46C 9318C Velocidades wB Control oocoass cimas Cord n Accionador Distribuci n del lujo de aire 3602 Aprobaciones oooccccco Catalogaci n UL El protector de malla cerrada del ventilador satisface las normas OSHA ooo f ars oso Tarara INFORMACI N GENERAL SOBRE SEGURIDAD 1 Cerci rese de que la fuente de electricidad se adapte a los requerimientos el ctricos del ventilador 2 El cord n el ctrico est equipado con una clavija a tierra de tres espigas que tiene que ser enchufada a un recept culo del mismo dise o Bajo ninguna circunstancia deber cortarse la espiga a tierra de la clavija De existir un recept culo de pared de dos espigas deber reemplazarse por uno de tres espigas debidamente puesto a tierra e instalado de conformidad con el C digo Nacional de Electricidad y todos los c digos y ordenanzas locales aplicables El trabajo deber hacerlo un electricista calificado utilizando exclusivamente alambre de cobre ADVERTENCIA NO SE RECOMIENDA EL USO DE UN ADAPTADOR DE TRES A DOS ESPIGAS LA CONEXION INDEBIDA PODRIA CREAR EL RIESGO DE SER ELECTROCUTADO EL USO DE TALES ADAPTADORES NO ESTA PERMITIDO EN CANADA Rev F 4 01 3 Siempre que sea posible evite el uso de extensiones el ctricas Si tienen que usarse minimice el riesgo de sobrecalentamiento asegur ndose de que sean de catalogaci n UL y d
4. MODELO 4YN46C 9318C ATENCI N ELCABLE DE APOYO SECUNDARIO SUMINISTRADO DEBE UTILIZARSE CUANDO QUIERA QUE EL VENTILADOR SEA MONTADO POR LO ALTO PARA MAYOR SEGURIDAD CABLE DE APOYO SECUNDARIO 1 Entrelazar el cabo del Cable alrededor de los Alambres de Di metro Grande tanto por la Parte Delantera como por la Parte Trasera de la Defensa del Ventilador Figura 2 2 Fijarla Mordaza del Cable de manera que la U del lado del cabo del bucle quede con cabo de 1 a 2 pulgadas aproximadamente Apretar las Tuercas de la Mordaza Hay que asegurarse de que ninguna parte del Cable estorbe a la Paleta Figura 2 3 Enroscar el otra cabo del Cable alrededor de una viga o armaz n segura de la edificaci n o de otro soporte cercano al Ventilador Figura 3 Recoger todo lo del cable que quede sobrando CUIDADO UTILIZAR S LO LOS ELEMENTOS MET LICOS DE MONTAJ E QUE SE RECOMIENDAN PARA ESTE VENTILADOR 4 Fijar la Mordaza de Cable restante como se indica en la parte 2 Hay que recortar el exceso de cabo de manera que s lo queden de 1 a 2 pulgadas despu s de la Mordaza 5 Revisar el Ensamblado para cerciorarse de que la Paleta est libre de toda obstrucci n ATENCI N EL USO DEL CABLE DE APOYO SECUNDARIO NO GARANTIZA LA PROTECCI N DE PERSONAS CONTRA LESIONES Y EL MONTAJE DEL VENTILADOR Y DEL CABLE PODR AN DANARSE SI SE MALTRATAN SE DESCUIDAN O NO SE INSTALAN BIEN Figura 2 Figura 3 Cable de Apoyo AR Secundar
5. amage the Fan Dry all parts with a soft cloth completely before reconnecting to power supply STORAGE When not in use keep unit in a clean dry place MOTOR IS PERMANENTLY LUBRICATED DESCRIPTION 2065510 Name Plate 2010636 Motor Cover Pull Cord with Pendant 5096056B Rear Grill 2091162 Screw 8 x 1 2 PPH Type F 2030021SB Motor 5090044 Set Screw 1 4 28 x 3 8 mn al 5090041 Rivet k N 2091143 Screw 8 x 3 8 PPH Type F co 2090547 Palnut N 2070027 Bullseye N Cable Lock Supplied in Hardware Bag 2098012 2084576 MANUAL DE INSTRUCCIONES DE OPERACI N Y PARTES Ventilation Products VENTILADOR DE ALTA VELOCIDAD Y MONTAJ E MULTIPLE 18 45 7 cm MODELO 4YN46C 9318C LEA Y GUARDE ESTAS INSTRUCCIONES L ALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR INSTALAR OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO PROTEJASE A S MISMO Y A LOS DEM S OBSERVANDO TODA LA INFORMACION SOBRE SEGURIDAD NO SEGUIR LAS INSTRUCCIONES PODR A RESULTAR EN LESIONES PERSONALES Y O DANOS A LA PROPIEDAD GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS DESCRIPCI N AirKing de ventilador para piso o para mesa y de 18 45 7 cm se caracteriza por el funcionamiento silencioso como murmullo con paleta de ventilador dividida en tres Tiene motor lubricado permanentemente con juego de alambre 18 3 de 9 pies 2 7 m ESPECIFICACIONES MOTOT cia o eeii 120V 50 60
6. de Identificaci n 1 SPECIFICATIONS 8 DO NOT use Fan in a window Rain may create an electrical hazard A 120V 50 60 Hz 18 45 7 cm 9 e Fan according to instructions before recon 3 2010636 Cubierta del Motor 1 Blade diameter 18 45 7 cm Model 4YN46C 9318C i A TTT 3 ae Pull Cord WALL CEILING INSTALLATION 5 ij Cord n Accionador con Colgante 1 Air flow distribution 360 1 WOOD STRUCTURES Locate the wall or ceiling stud nearest to Approvals c oooooccinoccccnoncccnnanacinnns UL Listed Close mesh Fan guard the desired Fan location Attach the Fan to the stud using a 3 8 illa T 1 meets OSHA requirements diameter x 2 long Lag Screw Not Supplied Figure 1 O ic Reja lasera NOTE ALWAYS INSTALL THE YOKE TO A MINIMUM OF 2 X 4 STUDDING 3 9 2091162 Tornillo de 8 x 1 2 PPH Tipo F 4 2 STEEL STRUCTURES Attach the Fan using a 3 8 bolt of the appropriate length with a Flat Washer Lock Washer and a 3 8 Nut CFM 5350 4180 3010 Not Supplied 203002156 ESMERO 3 MASONARY STRUCTURES Attach Fan using a 3 8 Lag Screw with a Lag Shield of appropriate length Not Supplied Figure 1 5090044 Tomillo Prisionero de 1 4 28 x 3 8 RPM 1600 1275 NOTE IN ALL CASES IT IS RECOMMENDED THAT A FLAT WASHER BE PLACED ON BOTH SIDES OF THE FAN YOKE TO ASSIST IN Watts 194 94 148 48 10 10 SMOOTH ROTATION 19 5090041 Remache 4 Attach Pull Cord String and Pendant to Switch 17 2091143 Tornillo de 8 x 3 8
7. el ctrica INSTALACI N EN PAREDES TECHOS 1 ESTRUCTURAS DE MADERA Localice el montante de pared o techo m s cercano a la ubicaci n deseada para el Ventilador Una el Ventilador al montante usando uno Tornillo de Retraso de 5 16 de dimetro x 2 de longitud No Proporcionados Figura 1 NOTA SIEMPRE INSTALE LA HORQUETA EN MONTANTES DE 2 X 4 COMO M NIMO 2 ESTRUCTURAS DE ACERO Fijar el Ventilador con un perno de 3 8 de longitud adecuada con Arandela Plana Arandela de Seguridad y Tuerca de 3 8 No Suministrada 3 ESTRUCTURAS DE MAMPOSTER A Fijar el Ventilador con un Tornillo Tipo Tirafondo de 3 8 con Maguito de Expansi n de longitud adecuada No Suministrado Figura 1 NOTA EN TODOS LOS CASOS SE RECOMIENDA QUE SE COLOQUE UNA ARANDELA PLANA EN AMBOS LADOS DE LA HORQUILLA DEL VENTILADOR PARA CONTRIBUIR A QUE EL GIRO SEA SUAVE 4 Fije el cord n accionador y la pieza colgante con el interruptor Montante de Techo o Pared Manguito de Expansi n S lo para Mamposter a En p i Arandela Plana Tornillo de Retraso Figura 1 2084576
8. el calibre y la longitud adecuadas Nunca use una sola extensi n para operar m s de un ventilador 4 No introduzca los dedos ni objetos extra os en el ventilador No obstruya ni manipule indebidamente el ventilador mientras est en operaci n No toque el ventilador mientras est en operaci n ni inmediatamente despu s de haberlo apagado ya que ciertas partes podr an estar lo suficientemente calientes como para causar una lesi n 5 Desenchufe el cord n el ctrico antes de instalar o dar servicio al ventilador ADVERTENCIA NO DEPENDA DEL INTERRUPTOR DE ENCENDIDO Y APAGADO COMO EL NICO MEDIO PARA INTERRUMPIR LA ALIMENTACI N EL CTRICA CUANDO INSTALE O DE SERVICIO AL VENTILADOR SIEMPRE DESENCHUFE EL CORD N EL CTRICO 6 Este ventilador es para uso general EXCLUSIVAMENTE NO deber usarse en localidades potencialmente peligrosas tales como atm sferas inflamables explosivas cargadas de gases o h medas ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGAS EL CTRICAS NO USE ESTE VENTILADOR CON NINGUN DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO SOLIDO 7 Aseg rese de que el ventilador est sobre una superficie estable al estar en funcionamiento para evitar toda riesgo de que se voltee 8 NO utilice el ventilador en una ventana ya que la lluvia podr a crear un peligro el ctrico 9 Vuelva a armar completamente el ventilador de acuerdo con las instrucciones antes de volver a conectarlo a la alimentaci n
9. io Alambres Grandes de la Defensa N OPERACI N 1 Enchufe el cable de conexi n el ctrica dentro de un tomacorriente de tres hojas conectado ampropiadamente a tierra 2 Utilizando el cord n accionador seleccione la velocidad deseada del Ventilador 3 ADVERTENCIA Este ventilador debe ser usa do solmente en unambiente limpio y seco Si producto esta montado de alguna otra manera espec fica que indica la hoja de instrucci n purdiera anularse y no tener valor la garantia del fabricante MANTENIMIENTO ADVERTENCIA DESCONECTE SIEMPRE EL CORD N ANTES DE INTENTAR REALIZAR CUALQUIER FUNCI N DE SERVICIO LIMPIEZA Use un trapo y una soluci n de jab n suave tal como detergente l quido para lavar trastes ADVERTENCIA No use gasolina bencina diluyente de pintura ni limpiadores fuertes en aerosol ya que stos da ar n el ventilador ALMACENAMIENTO Cuando no lo utilice mantenga el aparato en un lugar limpio y seco EL MOTOR HA SIDO PERMANENTEMENTE LUBRICADO OPERATING INSTRUCTIONS PARTS MANUAL Ventilation Products O HIGH VELOCITY MULTI MOUNT FAN 18 45 7 cm MODEL 4YN46C 9318C READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR
10. to 2 inches Tighten Clamp Nuts Make sure no part of the Cable interferes with the Blade Figure 2 3 Wrap the other end of the Cable around a secure building joist truss or other support near the Fan Figure 3 Take up all excess slack in the Cable CAUTION USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN 4 Attach the remaining Cable Clamp as indicated in Step 2 The excess tail should be trimmed to extend 1 to 2 inches past the Clamp 5 Check the Assembly to assure the Blade is free of all obstructions CAUTION USE OF THE SECONDARY SUPPORT CABLE DOES NOT GUARANTEE PROTECTION AGAINST INJURY OF PERSONS MOUNTING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL IF SUBJECTED TO ABUSE NEGLECT OR IMPROPER INSTALLATION Rev F 4 01 KEY PART NO Figure 2 Figure 3 7 Secondary Large Guard Wires Support no del Cable OPERATION 1 Plug the power cord into a properly grounded three prong receptacle 2 Using the Pull Cord Switch set the desired Fan Speed 3 WARNING This fan should be used only in a clean dry environment Mounting of this product in any way other then specified in the instruc tion sheet will null and void the manufacturers warranty MAINTENANCE WARNING ALWAYS UNPLUG CORD BEFORE SERVICING CLEANING Use a soft cloth and a mild soap solution such as liquid dish washing detergent CAUTION Do not use gasoline benzine thinner harsh cleaners etc which will d

Download Pdf Manuals

image

Related Search

Related Contents

型式 FR-s45A  LED LED 60W Scanner Light - Flash  TEFAL TT812116 Instruction Manual  PN-G655R / PN-HG655R 取扱説明書  Z8 encore! 64K Series MCU Development Kit User Manual, UM0151  Atlas Sound PS24-075 User's Manual  Samsung RCD-S30 User Manual  Hotpoint 16 Refrigerator User Manual  Peugeot user guide - GPS map  ASUS (ME170C) User's Manual  