Home

Aiphone TB-20M User's Manual

image

Contents

1. Any terminal on T add on selector Cail extension IER 2 one per TB M aS i th ae z a gt i i Mi ad 4 I The master can select the door station for audio monitoring at any time The call announce pretone is selectable Set the switch to ON position for pretone removing the cover of front case TB AD1 DC12V input E Wiring distance TB M to TB SE sub 0 8mm 1 0mm AWG _ 22AW Distance 400m 600m 900m 1 300 2 000 3 000 _22AWG 20AWG WL HONEOCEBA TB AD1 to audio door station S2AWG 20AWG 18AWG Distance 500 750 1 200 TB M to TB AD1 1 0mm 22AWG 20AWG 18AWG 150m 210 _ 330 Pre tone sounds at door Station when selected from TB M master The feature can be muted by switching to OFF E TB 10M single master with TB 20 40 G add on selector e TB M master with a TB G add on selector expands its capacity up to 60 substations Choose the master and add on selector to meet your system s requirements Master station TB 10M IN AC 15 16V or DC18V To power supply Sub station Add on selector TB 20G Door adaptor Sub station TB SE i 1 1 Hi lE E 2 E 2 E 4 1 14 E 2 z 12V 12V lt x Do not connect any 15 EI 2 ower source here 6 Ceni R 16 J a Call extension E r TB M u a ay E 9 1 18 E gt E
2. lo la H A E Bl 2 Oo fea a e fee e ee E E fis cs S al e A Lee es e a fr es fem ra TB AD1 OON H O e E H A fl Sl 2 e D el e e e N 5 3 8 le o gt N E fe a fel e E i N lt T A a E a al al ll eo S e e e e e e fe ea Do Da Da D7 Da 55 Da oa Da D E Meaning of terminal symbols E terminal is common calling and communication line No 1 40 terminals are selective station points providing selective calling and communication C amp M terminals are master to master communication R amp T terminals are master to door adaptor transmit and receive lines S amp S terminals are call tone output to IER 2 call extension speaker E TB 10M single master system with a door station The terminals on the master station connect to TB SE terminal 1 on each TB SE sub These numbers ial become the sub s station number numbered from the top on each 10 button row IF DA TB AD1 2 parallel wires per TB SE sub nonpolarized Be sure to run each pair of wires directly to TB M master E line in each pair should not be connected at any other point of cable than E terminals on TB M which can accomodate 2 3 TB SE subs Master station TB 10M IN AC 15 16V or DC18V To power supply Sub station Door adaptor TB AD1 2 10
3. 10 1 19 2 20 Connector Up to 3 TB AD1 door station adaptors per TB M 5 wires homerun to TB M E TB 20M single master with up to 10 door stations In place of TB SE handset subs TB M master may have max 10 door stations by using a TB AD10 adaptor Master station TB 20M IN IAC 15 16V or DC18V To power supply Sub station 10 call door adaptor Do not connect any power source here Cail extension IER 2 one per TB M TB AD10 10 call door adaptor may be wired to any terminal on TB M or TB G add on selector connecting max 10 IE IF door stations Features two way calling and communication with door TB AD10 Station including optional pretone Set the switch to ON position if pretone to door is required W Wiring distance LZ TB M to TB AD10 f AWG 22AWG ZOAWG 18AWG K ON H 4 OFF 210 330 TB AD10 to audio IF DA Diameter 0 65mm 0 8mm AWG 22AWG 20AWG 18AWG 500 750 1 200 a a E TB M dual master system prone eee eeene n ne e Common TB SE sub rings two TB M Masters a Single pair i a i i e Each master can call TB SE sub selectively il BROS 7 nonposanzed l i TB SE Master to master communication IF DA TB AD1 he en j j TB 10M E Gone Area TB SE 2 pairs polarized CPS TB 10M Master station TB 10M IN AC 15 16V or DC18V Master st
4. 60 stations max TB SE or door stations incl One add on selector TB 20G or TB 40G per TB M 1 to 3 TB AD1 door adaptors or one TB AD10 only alternatively or one TB ADM10 only TB SE sub s call in is annunciated with intermittent tremolo tone and LED lighting in red both of which are held approx 40 seconds for IE IF door stations Station select button calls each TB SE with intermittent tone Corresponding LED is lit to indicate which sub is called Master can call IE IF door station by voice with or without pretone selectable Both stations communicate simultaneously via handset 2 conductors parallel or a pair in multi cond cable TB M to ea TB SE 5 conductors TB M to TB AD1 14 conductors max TB M to TB AD10 3 conductors between TB M s In TB M dual master system two parallel conductors cables are required for each common TB SE sub ooo o o oo oomme omme omm 22AWG 2OAWG 18AWG emote 40m 600m 900m 1300 2000 3 000 _ TIBMtoTB M 200m 300m 480m 650 1000 1 570 TB M to TB AD1 65m 100 150m 210 330 495 TB AD1 10 to IE IF door 150m 230m 360m 500 750 1 200 Dimensions amp weight Model TB 10M TB 20M TB 20G TB 40G TB AD10 TB AD1 gt Aiphone LEEEEEEE EEE EEE SEES Height 117 mm 117 mm 97 mm 97mm 97 mm 140 mm Aiphone Co Ltd Nagoya Japan Aiphone Corporation Believue WA USA TB M I E O396F TB M system compon
5. with 20 to 40 additional subs In use LED l indicates TB M master is not put in standby Make sure handset is properly placed Attach the directory amp M Z 4 cover from left side to LAA RZ L WY BS QY Receiver upper amp call tone Call in LED p volume controls 3 levels Also indicates waiting for transfer of call Transfer switch amp LED Station select button E TB M single master system Calling and receiving To call a TB SE sub the other master or audio door station pick up Baa ence n for handset and depress a station select button When called by a tremolo tone pick up and depress the LED lit select button LED ed LED ae Pig aor l remains on while in communication Communicating TB M is notified of a call with a lit LED only The audible call tone will resume when the handset is hung up Do not press more than one buttons when calling Receiving a call from audio IE IF door station When the door station places a call with call button a tremolo tone is activated on the TB M which stays on approx 40 seconds The 77 master replies by selecting the station button that is lit At the door station when selected a pretone is heard unless it is muted at the TB AD1 10 adaptor Transfer allows two TB SE subs to communicate with each other When a master receives a call from sub A requesting transfer of call TB M leaves sub A waiting pressing a sub B select button When sub B
6. as an operation that when TB M1 places a call to either TB M2 or a common TB SE that is already in communication the talk line is connected among 3 parties It reduces communication volume One party should hang up to restore normal volume To call TB M master simply pick up and it rings TB M with tremolo tone which continues ringing until the call is answered Intermittent tone means the master is occupied Hang up or continue to hold When called by tremolo tone simply pick up The power switch is located on back panel of TB M console which should be placed ON except for special occasions may reset itself Possible causes are power supply is unplugged connecting wires are loosened or shorted Do not attempt to open TB M equipment nor change wiring Ask qualified personnel If the system malfunctions turn off and on TB M master by which the system At end of each communication be sure to place handset in cradle properly If not TB M master or TB SE sub will not hear the call tone The TB M is rated to operate at temperatures between 0 C 40 C 32 F 104 F Clean the TB M equipment with a soft cloth dampened with neutral household cleanser Never use any abrasive cleaner or cloth on Power source Power consumption Capacity Calling Communication Wiring Wiring distance Compatibility SPECIFICATIONS DC18V 350mA max or AC 15 16V 50 60Hz 750mA max 6W max 3W standby
7. as been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by PEEEEEEE PEE EES EES COMMUNICATION SYSTEMS HOME BUSINESS ONE INDUSTRY Printed in Japan E
8. ation TB 10M IN AC 15 16V or DC18V Polarized 4 To power supply i E 2 E 3 E 4 Door adaptor ar TB AD1 so Sub station t Designate any terminal for TB AD1 a lt k The number terminal E jumpered to M at each EEE EE Mi master establishes master C to master communication F 12 t Do not connect 12V 5 any power source T c R7 Call extension i Call extension IER 2 S IER 2 H TH IMPORTANT Do not use the following wiring methods They will cause the system E Wiring distance Between TB M masters i AWG 22AWG 20AWG T 18AWG 1 000 1 570 to malfunction Do not parallel sub station wires Door adaptor TB AD1 10 can only between TB M master stations be wired to one master Doors Wiring from TB SE must be cannot call both master stations homerun to EACH master station E E Connecting a buzzer at a TB SE sub When called by TB M master buzzer is activated and on TB SE sub call tone sounds at reduced volume TAR 3 relay activates an AC operated buzzer AC 240V 0 3A DC operated buzzer must be mechanical type DC 24V 1 0A Do not use DC electronic buzzer MOUNTING WE TB 10 20 M with TB 20 40 G Buzzer TB M master To power source TAR 3 DC6V 160mA Orange shorting link PS 6D power supply SKK 620 in USA Remove 2 screws on front panel removing the cover on up
9. ents TB 10 20 M TB 20 40 G amp TB AD 1 10 cannot be intermixed with TB 10 20 T masters while TB RC handset sub can be used with TB M system Width Depth Height Width Depth Weight 255mm x 230mm 4 5 8 x 10 x 9 1 8 kg 3 97 Ibs 330 mm x 230 mm 4 5 8 x 13 x 9 2 3 kg 5 07 Ibs 150mm x 230 mm 3 13 16 x 6 x 9 1 0 kg 2 20 Ibs 300 mm x 230mm 3 13 16 x 11 13 16 x 9 1 9 kg 4 19 Ibs 150 mm x 230mm 3 13 16 x 6 x 9 1 1 kg 2 43 Ibs 74mm x 42mm 5 1 2 x 3 x 1 5 8 160 g 0 35 Ibs ae eee Aiphone will not be responsible for any costs incurred involving on site service calls she oje eje efe ole eje efe efe efo oje sfe efe efe ole ofe oft fe oje ofe fe efe oje ole efe ele sjo ofe ole efo ole sje efe efo sfe ofe fs ole of eje ole ejo eje efe ole ofe oft ofe ofe ote ole ele of ole ole efe ole efe ote ole ale ole GA Sn sa aA a A ce i Se a A WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty This warranty shall not apply to any Aiphone product which h
10. ns TB 10M and TB 20M master station is streamline and modernly designed The master console may be placed on desk or wall mounted Power on switch on rear panel l Power on amp Piug in connector in use LEDs on the back Station select or call button with LED ay fe E gt LF rr Directory card z EZY and cover Receive amp call tone 405 mm volume controls 16 Transfer switch amp LED TB 10M with TB 20G add on selector The selector switch bank is aligned vertically with each station having its own directory Station numbers count top to bottom 1 to 10 on first switch bank and 11 to 20 on the second switch bank of TB 20M The supplied directory card and cover can be attached from the left Features Transfer switch and LED in the center of front panel Single transfer button automatically connects the master with the next TB SE sub that has called max 2 TB 20G or TB 40G add on selector plugs into TB M back panel and can be placed on either side of master W Features TB 20G or TB 40G add on selector connects additional TB SE subs allowing system expansion One or dual master configuration e TB AD1 adaptor connects TB M with an IE IF Series audio door station up to 3 For 4 to max 10 doors use a TB AD10 adaptor Or alternatively TB ADM10 adaptor for max 10 PanTilt door stations Allows TB M to communicate and monitor each MY door station audio visually either selectively or all in
11. per end and area section plate Lift off front case holding sides at top Disconnect the intercom by unplugging the connector Open a cable inlet hole rubber part on bottom of chassis Pull in cable s and make wire terminations Use attached cable clamps s for neat and secured connection Reconnect and mount front case to chassis attaching the cover and plate in place When wall mounting separate the front panel from chassis as explained above Install the chassis upside down on the wall onto a single gang or two gang box Desk top mounting Area section plate Lift off front case holding Screws sides at top hole Open a knock out Wail mounting Lift off front case holding sides at top Single gang or 2 gang box aw D Screws FTRS n Fy S Chassis mounts upside down TB M master wall mounts with TB G and TB AD10 attached Decide the exact location of TB M master and use the following measurements to mount the add on components TB M master TB G add on TB AD10 door selector adaptor Centers of each chassis or gang boxes Wali mounting guide Master Attached TB 10M TB AD10 TB AD10 2025 8 TB 20M TB 40G_ 15 0 12 1 2 TB AD10 225 0 9 _ 240 0 9 v2 OPERATIONS ER Single TB M system Speaker for call in tone Power on LED TB 10 20 M master communicates with 10 or 20 TB SE subs TB 20G or TB 40G add on communicates
12. picks up the call sub A hears a busy tone TB M depresses Transfer switch TB M then reselects waiting sub A with red LED on Three parties i are on the line and TB M may hang up Transfer switch amp LED J Door to master or master to master calls are not transferrable x If transfer LED is lit when a transfer is not being made it can be cleared by pressing transfer switch ed Oe eed ey g TB M places a buzzer activating call to a TB SE sub Buzzer sounds continuously at TB SE sub in addition to ordinary tremolo Pick up on the TB SE station that the buzzer is connected to Adjusting receive and call tone volume E TB M dual master system E TB SE sub operation be tia H n la Ej ij roi el Z ee ee Booted 1 i S TECHNICAL PRECAUTIONS Speaker for call tone a Upper control adjusts handset receiver volume CD when TB M does not hear a TB SE sub clearly Call tone a 2a Tone control adjusts ringing tremolo 3 levels 3 levels each TB M 2 LAGO eee Two masters call and communicate with each assigned select button Transfer of a sub s call to another on the other master is not possible A call from TB SE subs that are connected to two masters activates tremolo tone at both masters When the controlling TB M is busy the other TB M may pick up In this case the sub hears both tremolo and busy tones 7 Dual master h
13. sseoeio0 oe gt AIPHONE TB M Series INTERNAL TELEPHONE SYSTEM Models TB 10M TB 20M INSTALLATION amp OPERATION MANUAL CONTENTS FOYS TEMNOUTENE amp COMPONEN TSi a a 1 2 NAMES amp FEATURE Gorai E aE E E E 2 3 PRECAUTIONS ON INSTALLATION amp WIRING cccciccesscctaceiseescsccsvesivencvesbesteuecvshiaideuwsccrcecendedndenedatsteanesce 3 A N RING eea a a E E A a tA e ae 4 I MOUNTING renier S r A 9 OR TRATON rria N E N N 10 7 TECHNICAE PRECAUTIONS serions aE O 11 G GOIN Geremia a AA E NN 12 Bee SYSTEM OUTLINE amp COMPONENTS Hi Sysiem outline The TB M is an internal telephone type system expandable up to 60 subs and 2 masters Communicates with TB SE handset subs and IE IF door stations ia Mi Package contents Master station TB 10M or TB 20M Directory card amp cover Screws pack 2 types ea 4 pcs Wall mount cradle Installation amp Operation Manual TB 10M or TB 20M w TB 20G or TB 40G QQYO E Components available TB SE IF DA etc TB AD1 TB AD10 TB 20G TB 40G Sub station IE IF Series door station 40 call add on selector 20 cail add on selector 10 call door station adaptor 1 call door station adaptor up to 3 TB M components TB 10M TB 20M TB 20G TB 40G TB AD1 and TB AD10 are NOT compatible with TB 10T and TB 20T TB RC sub can be used with TB M SES E NAMES amp FEATURES E Names amp functio
14. succession Refer to the TB ADM10 Manual Call extension IER 2 allows incoming call tone to be heard at a remote location Master station can call sub by tone and optional external buzzer spe PRECAUTIONS ON INSTALLATION amp WIRING Do not attempt to install or connect wires on TB 10 20 M equipment while system s power supply is turned on TB 10 20 M masters TB SE subs and related equipment except door station are designed for indoor use only Do not install outdoors Do not connect any other power source than specified on terminals IN AC15 16V or DC18V Doing so can damage the TB M equipment Do not open any TB 10 20 M system components Ask qualified personnel All the products of other manufacturers power supply buzzer etc used for TB 10 20 M are not within our warranty and must be used under manufacturer or distributor s specifications and warranty Do not mount TB 10 20 M equipment in the following places as it may cause the system to malfunction High or extreme cold temperature areas under direct sunlight near equipment that varies in temperature front of air conditioner inside refrigerating warehouse etc _ Places subject to moisture or humidity extremes e Places subject to environmental conditions such as iron dust dust oil chemicals etc TB 10 20 M is an electrical appliance which must not be subjected to water or any other liquid Weather conditions s
15. uch as lightning storms may cause damage to TB M equipment It is suggested to take protective measures as follows e When an AC transformer is used TB 10M TB 20M AC trans AC 15 16V Install a surge arrester or DC 18V discharging voltage 100 180V Srde at a point close to the output ane taken to earth ground Grounded e When a DC power supply is used On the power supply with grounding terminal be sure to take the terminal to earth ground In this case it is not necessary to connect a surge arrester When using a power supply that has no grounding terminal install a surge arrester in the same manner as stated above Surge arrester SA 1 is available from Aiphone Cable requirements Use 2 conductor cable twisted or non twisted homerun to each sub station 0 65 1 0mm 22 18AWG Before TB 10 20 M is actually installed the contents on pages 4 9 must be thoroughly read and understood 4 WIRING E Terminal block layout TB 10M lt qa Connect power supply to TB M Master station _ Max 25m 1 0mm 80 18AWG alee or AC15 16V lt q Each E terminal may have one to three wires from TB SE terminal 2 2 wires from TB SE subs must not be made common at any other point than on the TB M terminal block H H 8l te le N fel fed FS e st E lt HH H al le Sy e e e e bs E N lt lo l H H El D E al m mA E a a im