Home

Agilent Technologies E5070BU User's Manual

image

Contents

1. Completing the Network Identification Wizard You have succesfully completed the Network Identification Wizard To close this wizard click Finish lt Back Finish Cancel e5070bqj005 Chapter 2 11 Figure 2 9 Step 1 Step2 Step 3 Step 4 Step 5 NOTE Step 1 Step2 Step 3 Step 4 Option Installation Update Procedure Calibration of the Touch Screen When you have replaced the HDD on an E5070B E5071B equipped with an Option 016 touch screen you have to calibrate the touch screen Follow the procedure described below to calibrate the touch screen Press System Press Service Menu Press Test Menu Press Adjust Touch Screen The touch screen calibration screen Figure 2 9 appears Touch Panel Calibration Screen is received within 10 nds Press escape to abort the cali ion process Touch the x mark on the upper left with your finger The mark x appears also on the lower left upper right and lower right Touch the x marks in that order with your finger Touching the four locations described above with your finger automatically concludes the touch screen calibration With no operation on the touch screen calibration screen for a preset time it automatically closes and the previous measurement screen reappears Caution for replacing the spare HDD with the original HDD The RestoreSysCorFile vba is required to write the system correction data stored in the bac
2. e Caution for replacing the spare HDD with the original HDD Update Procedure Installation Requirement TORX Screwdriver T10 Removing Removable Hard Disk Follow the steps below to remove a removable hard disk CAUTION Before removing a hard disk you must turn off the unit s power and then disconnect the power cord from the outlet Step 1 Step 2 Step 3 Step 4 Step 1 Step 2 Step 3 Unscrew the four screws that hold the cover panel 1 in Figure 2 1 Remove the panel Unscrew the four screws that hold the removable hard disk 1 in Figure 2 2 Carefully remove the flat cable 2 in Figure 2 2 from the removable hard disk Release the cable s connector by pressing the locking hooks at the sides of the connector Mounting Removable Hard Disk Follow the steps below to mount a removable hard disk Connect the removable hard disk to the flat cable s connector 2 in Figure 2 2 Secure the removable hard disk in place with the four screws 1 in Figure 2 2 Secure the cover panel in place with the four screws 1 in Figure 2 1 1 Flat cable with connector outfitted 6 Chapter 2 Option Installation Update Procedure Figure 2 1 Mounting Removing Removable Hard Disk 1 e5070buj7016 Figure 2 2 Mounting Removing Removable Hard Disk 2 Chapter 2 7 Figure 2 3 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Option Installation Update Procedure Writing System
3. hardkeys or a toolbar setup toolbar labeled Sample Sample 1 Sample 2 Sample 3 Indicates a sequential operation of Sample 1 Sample 2 and Sample 3 menu button or box 66 99 may be omitted General Information This chapter describes the Kit contents of the kit and required tools to install the Option 018 into the Agilent E5070B E507 1B Table 1 1 General Information Option 018 Hard Disk Drive Kit Option 018 Hard Disk Drive Kit The purpose of this kit is to install the option 018 Hard Disk Drive into the Agilent E5070B E5071B Contents of the Agilent E5070BU E5071BU Option 018 Hard Disk Drive Kit The kit includes the parts listed in Table 1 1 If anything is missing contact the nearest Agilent Technologies office Contents of the Agilent E5070BU E5071BU Option 018 Hard Disk Drive Kit Description Qty Upgrade Manual This manual 1 HDD Assembly 1 Chapter 1 Option Installation This chapter describes the procedure to install the option 018 into the Agilent E5070B E5071B Option Installation Introduction Introduction This chapter describes the procedure to install Option 018 into the E5070B E5071B The procedure consists of the following items e Installation Requirement e Removing Removable Hard Disk e Mounting Removable Hard Disk e Writing System Correction Data of Backup Memory to Removable HDD e Calibration of the Touch Screen
4. 70bqj004 Step 4 The Network Identification wizard appears Click the Next gt button Figure 2 6 Figure 2 6 Network Identification wizard Welcome to the Network Identification Wizard Ths wizard helps you connect your computer to network To continue cick Next lt Back Next gt Cancel 25070bqj002 10 Chapter 2 Option Installation Update Procedure Step 5 In the Network Identification Wizard dialog box 1 2 select the Windows always assumes the following user has logged on to this computer box and check that agena is in the User Name box If not type in agena Finally click the Next gt button Figure 2 7 Figure 2 7 Network Identification Wizard dialog box 1 2 Network identification Wizard Users of This Computer Who can fog on to this computer You can require all users to enter user name and password to log on or you can have Windows assume the same user will always log on to this computer Which option do you prefer User must enter a user name and password to use this computer indows always assumes the following user has logged on to this computer agena lt Back Next gt Cancel x smt 25070bqj003 Step 6 In the Network Identification Wizard dialog box 2 2 click the Finish button to finish the initial registration of the E5070B E507 1B Figure 2 8 Then the measurement display of theE5070B E5071B appears Figure 2 8 Network Identification Wizard dialog box 2 2
5. Agilent E5070BU E5071BU Option 018 Hard Disk Drive Kit User s Guide Second Edition ie Agilent Technologies Agilent Part No E5070 90119 June 2005 Printed in Japan Notices The information contained in this document is subject to change without notice This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of the Agilent Technologies O Copyright 2005 Agilent Technologies Manual Printing History The manual s printing date and part number indicate its current edition The printing date changes when a new edition is printed Minor corrections and updates that are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated May 2005 First Edition June 2005 Second Edition Typeface Conventions Sample bold Boldface type is used when a term is defined or emphasis Sample Italic Italic type is used for emphasis key Indicates a hardkey key on the front panel or external keyboard labeled Sample key may be omitted Sample menu button box Indicates a menu button box on the screen labeled Sample which can be selected executed by clicking menu button or box may be omitted Sample block toolbar Indicates a block group of
6. Correction Data of Backup Memory to Removable HDD The following is a description of the procedures to write the system correction data stored in the backup memory to the mounted removable HDD Turn on the E5070B E507 1B Press Macro Setup Press Load Project on the softkey menu A dialog box appears to allow you to select a program to be loaded Select RestoreSysCorFile vba from the D Agilent Service folder and then press Open button Press Macro Run RestoreSysCorFile dialog box appears Figure 2 3 Click OK RestoreSysCorFile Dialog Box RestoreSysCorFile 4 01 00 x This program will restore system correction data files From the non volatile memory to the hard disk drive You must restart the firmware after restoring files Are you sure you want to continue a Cancel e5070buj7017 CAUTION Once the program has ended restart the E5070B E5071B to enable the system correction data 8 Chapter 2 Option Installation Update Procedure Initial Registration of E5070B E5071B When you start up the E5070B E507 IB for the first time or after executing system recovery you need to perform the initial registration of the Windows 2000 operating system of the E5070B E5071B NOTE You cannot use the front panel keys during the initial registration of the E5070B E5071B therefore connect the mouse and the keyboard before turning on the power NOTE If you perform the following procedure incorrect
7. kup memory to the orignal HDD Execute the following steps to copy the RestoreSysCorFile vba file Copy the RestoreSysCorFile vba file from the D Agilent Service folder to a FD before replacing the spare HDD with the orignal HDD Set the orignal HDD Confirm that the RestoreSysCorFile vba file exists on the D Agilent Service of the original HDD If the file does not exist copy the RestoreSysCorFile vba file from the FD to the D Agilent Service folder of the original HDD 12 Chapter 2
8. ly a message asking you whether to return to the previous registration screen and perform the registration appears In this case follow the instruction to return to the previous registration screen Step 1 Turns on the E5070B E5071B Step 2 The Windows 2000 Professional Setup wizard appears Click the Next gt button Figure 2 4 Figure 2 4 Windows 2000 Professional Setup wizard Welcome to the Windows 2000 Setup Wizard lt Back Next gt e5070bqj001 Chapter 2 9 Option Installation Update Procedure Step 3 In the Windows 2000 Professional Setup dialog box select the I accept this agreement box and click the Next gt button Figure 2 5 Then the Windows 2000 operating system is restarted automatically Figure 2 5 Windows 2000 Professional Setup dialog box Windows 2000 Professional Setup License Agreement i Do you accept the terms of the License Agreement for Windows 2000 BP erent Please read the following License Agreement Press the PAGE DOWN key to see the rest of the agreement To continue with Setup you must accept the agreement bd ETE EERE TEER TESTE ENTE EET OTE E TTT E NOE Microsoft Windows 2000 Professional Licensed Copes eee t Pert Peer feet i err irri ie END USER LICENSE AGREEMENT TOPO PEER FETT TST TTR TEER TEE EEE Ee IMPORTANT READ CAREFULLY This End User License Agreement accept this agreement I don t accept this agreement lt Back Next gt e50