Home
ADTRAN Hub User's Manual
Contents
1. ME m 13538 sn SIN 9 ee sud md Y 6 O O uso uvae Figure 4 Wall mount Attachment Assembly EE 61181012L1 5C Installation Tools Required NOTE Wall mounting hardware and tools are not included The following tools are required to mount the 10Base T Hub to a wall Small flat tip screwdriver 1 Phillips head screwdriver Depending on the mounting surface wood screws dry wall fasteners or cement type wall fasteners Awl or drill with assorted wood or cement bits Hammer Pliers Line cutters Wall Mount Instructions To mount the 10Base T Hub to a wall complete the following steps NOTE The 10Base T Hub ships pre assembled to the external mounting bracket and unassembled from the internal mounting bracket The 10Base T Hub must be disassembled before performing the following instructions See Figure 3 and Figure 4 for details on dis assembling and assembling the 10Base T Hub Remove the hub from the external mounting bracket by removing the flathead screw near the power connector that secures the hub to the bracket Slide the hub away from the tab and lift off the bracket see Figure 4 Locate a place to mount the 10Base T Hub that allows for sufficient slack in the RJ 45 cables Use the external mounting bracket as a template and mark the location of the mounting holes for the 10Base T Hub to be installed After marking the hole locations remove the mounting plate
2. ADRAN aypa 567 EUX R1 2 ODER mM RESET M LL PORTS CONF TOA 10Base T Hub Installation and Maintenance Practice Document Number 61181012L1 5C CLEI SIM3FGOD _ November 2007 10Base T Hub Installation and Maintenance Practice Trademarks Any brand names and product names included in this document are trademarks registered trademarks or trade names of their respective holders To the Holder of the Document The contents of this document are current as of the date of publication ADTRAN reserves the right to change the contents without prior notice In no event will ADTRAN be liable for any special incidental or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this document ADRAN 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2007 ADTRAN Inc All Rights Reserved o O i 61181012L 1 5C Revision History Revision Date Description A January 2001 Initial release B February 2007 Correct CLEI code update compliance information November 2007 Updated to show there are two mounting brackets that ship with this unit Conventions The following typographical conventions are used in this document This font indicates a cross reference link This font indicates screen menus fields and parameters THIS FONT indicates keyboard keys ENTER ESC ALT Keys that are to
3. gt ames sir as peo ee oo ade bas ea A oia daa albo ese ea a 3 Se RS 3 COMPIANCO os 6 5 ete ee 4 INSlANAUON n A EEES E AAA AAA 5 SD DIS COM serra ga ccc sa iros ee ose boo bas a ri apt 0 dy a dc Dd 5 Installation Prerequisites eee eee eee eee 5 Installing the 10Base T Hub 0 0 cc ee eee RR AA rra 6 Wall Mount Installation 0 0 ee ee eee eee eee ee 6 Tools Required 0 0 cc ee ee eee hh ss 7 WaleMount INSWUCUIONS 3 5 aur notes eee IRE oies cit re Dean Ee Seas et desu er es 7 Rack Mount Installation eee eee eee 8 Tools R g ired osos perrera a bade EU P ewe ee PI EU PIC sees EE 8 Chassis Mount Instructions ee eee ee eee ees 8 Bay Framework Mount Instructions 9 Desk Mount Installation 0 0 0 0 0 0 hrs 9 COMMECIONS ee Se ars Gees Ae aie a en se SRE eee Re eee eee 10 MAMMENN Orsara nana cave dames ait ee a eke oe ke wet eee ee ee wee a 11 led Le ane meta arrasar be Re ORES EEE ERS ni SRE ERE ed bic bei ae ee eee 11 Appendix A WIAA a tee eee tee DO 10 0 1772111 1 207 a eee ee do to aan oi A 1 Warranty and Customer Service 0 00 ce es A 1 ADTRAN Sales ae ee de a D Sele en dl ee eee de OE eR eee ee A 1 ADTRAN Technical Support A 1 ADTRAN Repair CAPS sees eese hh hh hs sas A 1 Repair and Return Address 2cdca vsceduceeedinetetuseSsuenGs Xu a TR en A 1 61181012L 1 5C
4. CAPS Department 901 Explorer Boulevard Huntsville Alabama 35806 2807 61181012L1 5C A 1 ADRAN Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806
5. V 10Base T Hub Installation and Maintenance Practice Figure 1 Figure 2 Figure 3 Figure 4 Table 1 Table 2 Table 3 Table 4 vi Figures 10Base T HUD P 1 Rear Panel RJ 45 Jacks 4444440 2 Side Panel Terminal Block a a a a a a a 2 Wall mount Attachment Assembly 6 Front Panel Description cc ee ee eee eee 3 Compliance COdCS o ecse ireas st eee eee na cet teh ead ga eeoeeetade Cru IUS ease 4 48 VDC Connections scele hh hh hh 10 TOBase T Hub Specifications i22 an Rma REG 4 Bde Oe Doe EON ORE LAORE a dues 11 EEE 61181012L1 5C 10Base T Hub INTRODUCTION The ADTRAN 10Base T Hub is a compact lightweight hub that delivers 10Base T connec tivity The 10Base T Hub can also be used to increase the density of existing services Figure 1 illustrates the 10Base T Hub P N 1181012L1 front panel ADRAN oso ANS 57 ANT A Cl US RESET PW LL PORTS cot Mt STD 1950 Figure 1 10Base T Hub Description The 10Base T Hub has eight 10Base T Ethernet ports that support up to seven platforms or equipment It is housed in a metal enclosure and can be mounted in three different ways Mounting The 10Base T Hub can be mounted using one of the following three methods Wall mount mounting to a vertical surface Rack mount mounting
6. of a Common Bonding Network CBN The 10Base T Hub is not designed nor intended for installation as part of an Isolated Bonding Network IBN CAUTION Per GR 1089 CORE Section 9 the 10Base T Hub is designed and intended only for installation in a DC C common bonding and grounding system The 10Base T Hub is not intended or designed for installation in a DC I isolated bonding and grounding system NOTE The 10Base T Hub P N 1181012L1 does not require the use of an external AC Surge Protection Device However for highly exposed AC mains environments an external AC Surge Protection Device is recommended O 4 61181012L1 5C Installation INSTALLATION CAUTION SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED After unpacking the 10Base T Hub inspect it for damage If damage has occurred file a claim with the carrier then contact ADTRAN Customer Service Refer to Appendix A Warranty for further information If possible keep the original shipping container for returning the 10Base T Hub for repair or for verification of shipping damage Shipping Contents The contents include the following items e lOBase T Hub e lOBase T Hub Installation and Maintenance Practice P N 61181012L1 5 e An external mounting bracket that is shipped assembled to the hub and is used for wall mount and chassis mount e An internal mounting bracket that is shipped unassembled with t
7. practice Desk Mount Installation To mount the 10Base T Hub to a desk complete the following steps 1 Remove the 10Base T Hub from the bracket as it will not be used in this application 2 Attach the rubber desk mounts to the bottom of the 10Base T Hub 3 Plug in cables and set the unit on a flat surface Allow adequate slack in the RJ 45 cables For more information refer to the Connections on page 10 in this practice 61181012L1 5C 9 10Base T Hub Installation and Maintenance Practice Connections All Ethernet connections are made using the RJ 45 jacks labeled 1 through 8 located on the rear panel The first jack is also designated as the cross over jack it is controlled by the cross over switch located at the far right of the rear panel NOTE To daisy chain the 10Base T Hub to other hubs place the rear panel switch see Figure 2 in the left cross over position x To use as a LAN port put in the right position The 10Base T Hub provides for a single voltage input a single voltage return and a frame ground Table 3 shows the connections Table 3 48 VDC Connections Label Connections _ 48 VDC 48 VDC Return m Frame Ground SC 61181012L1 5C Maintenance MAINTENANCE The 10Base T Hub does not require routine maintenance for normal operation Do not attempt repairs in the field Repair services may be obtained by returning the defective unit to ADTRAN Refer to Appe
8. the bay framework complete the following steps NOTE The 10Base T Hub ships pre assembled to the external mounting bracket and unassembled from the internal mounting bracket The 10Base T Hub must be disassembled before performing the following instructions See Figure 3 and Figure 4 for details on dis assembling and assembling the 10Base T Hub 1 Remove the hub from the external mounting bracket by removing the flathead screw near the power connector that secures the hub to the bracket Slide the hub away from the tab and lift off the bracket see Figure 4 2 The external mounting bracket removed from the 10Base T Hub in step 1 will not be used in this application The internal mounting bracket shipped unassembled from the 10Base T Hub will be used instead 3 Mount the internal bracket through the flange to anywhere on the bay framework 4 Attach the 10Base T Hub to the mounting bracket via the keyholes on the bottom of the 10Base T Hub The front panel of the 10Base T Hub must be facing the side flange o Use the flush mount phillips head screw to secure the 10Base T Hub to the bracket through the small lip on the side of the bracket The orientation is correct if the lip is flush against the 10Base T Hub on the side containing the power connection terminal block 6 Put the 10Base T Hub on the bay framework mount bracket 7 Connect the RJ 45 cables For more information refer to the Connections on page 10 in this
9. be pressed simulta neously are shown with a plus sign ALT X indicates that the ALT key and X key should be pressed at the same time This font indicates references to other documentation and is also used for emphasis This font indicates on screen messages and prompts This font indicates text to be typed exactly as shown This font indicates silkscreen labels or other system label items This font is used for strong emphasis NOTE Notes inform the user of additional but essential information or features CAUTION Cautions inform the user of potential damage malfunction or dis ruption to equipment software or environment WARNING Warnings inform the user of potential bodily pain injury or death 61181012L1 5C iii 10Base T Hub Installation and Maintenance Practice Training ADTRAN offers training courses on our products These courses include overviews on product features and functions while covering applications of ADTRAN s product lines ADTRAN provides a variety of training options including customized training and courses taught at our facilities or at customer sites For inquiries concerning training contact ADTRAN Training Phone 800 615 1176 ext 6996 Training Fax 256 963 6217 Training Email training adtran com EE IV 61181012L1 5C Contents OC TO ee da de da neo ta ieee coton 1 DESCIDUION NS ae ne da rana Dot oi Some ue es 1 MOUNANO PR 1 CONR CIONS sa rasos ee L 2 Seni
10. e basic features of the 10Base T Hub include the following Uses 48 VDC no power adapters required for Telco environment Supports eight 10Base T Ethernet ports Provides a reset button on the front panel Provides front panel LEDs for power and port status Provides modular RJ 45 jacks for equipment connections Can be mounted on a wall in a rack or on a desk Complies with UL 60950 requirements Complies with NEBS Level 3 61181012L1 5C 3 10Base T Hub Installation and Maintenance Practice Compliance CAUTION Electrostatic discharge ESD can damage electronic modules When handling modules wear an antistatic discharge wrist strap to prevent damage to electronic components Place modules in antistatic packing material when transporting or storing When working on modules always place them on an approved antistatic mat that is electrically grounded Figure 2 shows the compliance codes for the 10Base T Hub The 10Base T Hub is NRTL listed to the applicable standards It meets or exceeds all the applicable requirements of NEBS Telcordia GR 63 CORE and GR 1089 CORE The 10Base T Hub is intended for deployment in Central Office CO type facilities EEEs EECs and locations where the NEC applies Table 2 Compliance Codes Code Input Output Power Code PC A Telecommunication Code TC Installation Code IC F C CAUTION Per GR 1089 CORE the 10Base T Hub is designed and intended for installation as part
11. from the wall Drill a hole into the wall to accommodate the wall fasteners being used Do not make the holes too large o Mount the bracket to the wall 6 Attach the 10Base T Hub to the mounting bracket through the keyholes on the bottom of 61181012L 1 5C the 10Base T Hub The front panel of the 10Base T Hub must be facing the side flange Use the flush mount phillips head screw to secure the 10Base T Hub to the bracket through the small lip on the side of the bracket The orientation is correct if the lip is flush against the 1OBase T Hub on the side containing the power connection terminals 10Base T Hub Installation and Maintenance Practice 8 Put the 10Base T Hub on the wall mounted bracket 9 Connect the RJ 45 cables Refer to the Connections on page 10 in this practice Rack Mount Installation There are two procedures for mounting the 10Base T Hub to a rack e Chassis Mount Instructions on page 8 e Bay Framework Mount Instructions on page 9 Tools Required The following tools are require to mount the 10Base T Hub to a rack e Small flat tip screwdriver e 1 Phillips head screwdriver e Line cutters Chassis Mount Instructions To mount the 10Base T Hub to a chassis complete the following steps NOTE The 10Base T Hub ships pre assembled to the external mounting bracket and unassembled from the internal mounting bracket The 10Base T Hub must be disassembled before performing the followi
12. he hub and is used to bay framework mount the unit e Rubber desk mounts e Four 6 32 x 3 16 flathead screws one cable tie and five 12 24 x 3 8 screws Installation Prerequisites Before installing the 10Base T Hub observe the following Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designated for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines When installed this unit is intended to be used behind devices that provide primary lightning protection The 10Base T Hub ships pre assembled to the external mounting bracket and unassembled from the internal mounting bracket It is necessary to disassemble the 10Base T Hub before installing on a wall or in a rack See Figure 3 and Figure 4 for details on disassembling and assembling the 10Base T Hub 61181012L 1 5C 5 10Base T Hub Installation and Maintenance Practice Installing the 10Base T Hub The 10Base T Hub can be mounted using any one of the following three methods e Wall Mount Installation on page 6 e Rack Mount Installation on page 8 e Desk Mount Installation on page 9 Wall Mount Installation Use the wall mount method of installation to secure the 10Base T Hub to a vertical surface 0661 015 Lu BA
13. ndix A Warranty for further information SPECIFICATIONS Table 4 lists the specifications for the 10Base T Hub Table 4 10Base T Hub Specifications Specification Description Environmental Operating Temperature 0 C to 50 C Storage Temperature 40 C to 85 C Relative Humidity 95 percent maximum 50 C noncondensing Power Maximum Current Draw 48 VDC Maximum Heat Dissipation 2 watts Physical Dimensions Height 1 25 inches Width 3 78 inches Depth 5 56 inches Weight lt 1 pound Part Number 10Base T Hub 1181012L1 61181012L1 5C 11 12 This page is intentionally blank EEE 61181012L1 5C Appendix A Warranty WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can be found at www adtran com warranty Refer to the following subsections for sales support Customer and Product Service CAPS requests or further information ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre Sales Applications Post Sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256 963 8722 Repair and Return Address Contact CAPS prior to returning equipment to ADTRAN ADTRAN Inc
14. ng instructions See Figure 3 and Figure 4 for details on dis assembling and assembling the 10Base T Hub 1 Remove the hub from the external mounting bracket by removing the flathead screw near the power connector that secures the hub to the bracket Slide the hub away from the tab and lift off the bracket see Figure 4 2 The external mounting bracket is designed to replace either of the side flanges that mount the chassis to the bay Carefully remove either of the side flanges attached to the chassis and replace them with the mounting bracket provided with the10Base T Hub Tighten the chassis to the bay Ensure two phillips head screws are attached to the center two holes closest to the edge opposite the flange on the bracket 3 Attach the 10Base T Hub to the mounting bracket through the keyholes on the bottom of the 10Base T Hub The front panel of the 10Base T Hub must be facing the side flange 4 Use the flush mount phillips head screw to secure the 10Base T Hub to the bracket through the small lip on the side of the bracket The orientation is correct if the lip is flush against the 10Base T Hub on the side containing the power connection terminal block 5 Put the 10Base T Hub on the rack mounted bracket 6 Connect the RJ 45 cables For more information refer to the Connections on page 10 in this practice ee 8 61181012L1 5C Installation eC tes SS eee Bay Framework Mount Instructions To mount the 10Base T Hub to
15. to the outside of an ADTRAN multi service access platform or to the relay rack itself Desk mount mounting to a desk or similar horizontal surface 61181012L 1 5C 1 10Base T Hub Installation and Maintenance Practice Connections The 10Base T Hub incorporates eight 10Base T Ethernet ports including one cross over LAN connector daisy chain port Up to seven platforms or other equipment can be connected to the hub using its 10Base T Ethernet ports All Ethernet equipment connections to the 10Base T Hub are made using modular RJ 45 jacks labeled 1 through 8 located on the rear panel see Figure 2 Power connections are made to a terminal block located on the side panel of the 10Base T Hub see Figure 3 e A cross over switch allows the first port to connect directly to the LAN or allows the daisy chaining of multiple hubs Figure 3 Side Panel Terminal Block 2 61181012L1 5C Introduction Controls The 10Base T Hub has nine front panel LEDs for power and port status and a front panel reset button The reset button can be used without removing power Table 1 describes the LEDs and the reset button on the front panel Table 1 Front Panel Description Status Description PWR O Off No power to the unit o Green Power is present PORTS Off No Ethernet link 1 8 o Green Normal operation Green Flashing Data is being transferred RESET N A Resets the unit without removing power Features Th
Download Pdf Manuals
Related Search
Related Contents
CP-WU8440 SMC Networks SMC2755W User's Manual コラボカタログ [PDF:11428KB] Installation manual Skid plate for: engine bay Triarch 31184 User's Manual Common manual of TS-1093 and TS-1068 iOS and User Manual for By SALT Solutions, Inc. Blackberry 8700 Cell Phone User Manual Le marketing Copyright © All rights reserved.
Failed to retrieve file