Home
Admiral AAW-24CR3FHU User's Manual
Contents
1. Mounting Brackets 2 Double Angle Adhering Brackets 2 Seal 1 v End Cap amp Leveling Legs 2 NOTE Surplus screw s for spare use Tools Needed for Window Installation Screw drivers Both Philips and flat head Power drill 1 8 inch diameter drill bit Pencil Measuring tape Scissors Carpenters level Installation instructions A CAUTION A Because the compressor is located on the controls side of the unit right side this side will be heavier and more awkward to manipulate Inadequate support on control side of the unit can result in personal injury and damage to your unit and property Therefore it is recommended to have someone assist you during the installation of this unit 1 Select the Best Location A Your room air conditioner was designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and frame is structurally sound and free from dry and rotted wood C For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over the unit D Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit See Fig B The rear
2. revestimiento de la tira y p guela al marco Fig 8 Veala Fig 9 A PRECAUCION A ne Utilice un taco de madera para proporcionar ae estabilidad Esto serdnecesario cuandoel umbral dela ventana sobresalga mucho del a E a a Sello plano de la pared Vea la Fig 8 Fig 9 24 Instrucciones de instalaci n 6 Instalaci n del gabinete A Alinee un agujero de la parte inferior del gabinete con un agujero del soporte ensambla do Sujete el gabinete al soporte ensamblado con 3de lostornillos de 1 4 proporcionados Repita el mismo procedimiento del otro lado del gabinete Vea la Fig 10 B Aseg rese de que el canal de montaje en forma de L est delante del marco El canal en forma de U de la parte inferior del gabinete de ber quedar en el riel del soporte ensamblado Baje la ventana hasta que apoye justo detr s de la parte delantera del canal de montaje en forma deL Vea la Fig 11 C Aseg rese de que el gabinete est levemente inclinado hacia abajo en la parte externa Si es necesario vuelva a ajustar el soporte tal como se indica en la Fig 7 7 Asegurelas Persianas A Vuelvaa colocar con cuidado el aire acondicionado en el gabinete Pida ayuda para realizar este procedimiento B Vuelvaa instalarlos tornillos del armaz n deslizable que se quitaron anteriormente de ambos lados del gabinete Vea la Fig 12 Asegure la parte sup
3. CCC CUCULI a mE Double Adhering seal 1 4 Screw For 10K to 12K models For 18K to 24K models Factory Installed Fig 3 Shutter Frame 1 4 screw Right Shutter Installation instructions 5 Installation of Mounting Brackets and First Sealing Strip TOP VIEW V slot gt ll a os O gt NOTE Windows come in a variety of different styles Therefore it may be necessary to modify or improve your particular installation 0 00 66 Ooo 0 0 Bracket Assembly 90 Angle Support Brackets Bracket Bolts Leveling Screw _ gt A Attach the bracket assembly to 90 angle support brackets Fig 5 using 2 1 1 2 bolts Two bolts per bracket Secure with the 2 A 1 4 lock washers and 2 1 4 nuts DO NOT vaol immediately tighten these bolts as it may be Center necessary to adjust the depth of the bracket Al LE assembly depending on the depth of your window sill om L See Fig 7 Install the two leveling screws into the p 90 support brackets Test the bracket assembly in the 126 136 Measurement for Model 10K 9 6 window before cabinet installation If the leveling Measurement for Model 12K 10 3 Window sill Measurement for Model 18K to 24K 12 6 screws are dista
4. Entrada de Palanca de Aire Fresco Aire Exterior Cable de Alimentaci n Nota Las im genes de este manual est n basadas en la vista externa de un modelo est ndar En consecuencia es probable que la forma sea diferente a la del aire acondicionado que usted seleccion Identificaci n de las Piezas gt Modelo de Remoto controlador Panel Frontal Gabinete o Panel de Control Filtro de Aire S 4 TU AI OIR IZ AR RRR ARIZA PA RIN RAI SNR NOS ROKR RIOR a l K A 00 ROI KIY ROX x XR OR DKK KCK OK AIR SOHN LX KKK o gt SRR ARSON RRR NRA RROD KOKI PIKE KG IK RIK A KKH BIKINI III DO LRA POOR A KR E A bOI REG RN RRR RRR X PAOI RA RIRIA IAS L MA Rejilla de Entrada de Aire Interior WCC CC Entrada de Aire Exterior Palanca de Aire Fresco Cable de A
5. El rango de horas para programar el temporizador es de 0 a 24 horas Si selecciona OFF TIMER la pantalla del temporizador indicar durante 12se gundos el tiempo restante para el apagado de la unidad y luego indicar la temperatura fijada Si presiona el bot n TIMER dentro de esos 12 segundos se desactivar la funci n OFF TIMER Si selecciona ON TIMER la pantalla del temporizador indicar el tiempo restante para el encendido de la unidad Si desea cancelar la funci n ON TIMER presione el bot n TIMER Bot n A y Se utiliza para fijar la temperatura ambiente en modo COOLING o para programar la hora en modo TIMER Sise presionan las dos teclas a la vez el indicador de temperatura alternar entre C y F NOTA el rango de temperaturas oscila entre 19 C 66 F y 31 C 88 Instrucciones de Operacion y Control remoto 0 Boton Power Encendido Apagado El aparato se encender si est apagado o apagar cuando est en operaci n si oprime este bot n E Bot n Mode Modo 0 8 18 Utilice este bot n para seleccionar Power Timer el modo de operaci n O e e Mode Power Saver E Bot n Botones de ajuste detemperatura oprima 7 om m para ajustarla temepratura del cuarto O F Fan Speed F oprima para programar la hora O e Boton High sz Temp Time Para ajustar el modo alta velocidad de ventilador Bot n Mid Para ajustar el modo mediana veloci
6. Admiral Room Air Conditioner Aire Acondicionado para Habitaciones Use and Care Manual Manual de Uso y Mantenimiento Remote control AAW 10CR1FHU AAW 10DR3FHU AAW 12CR1FHU AAW 12DR3FHU AAW 18CR3FHU AAW 18DR3FHU AAW 24CR3FHU AAW 24DR3FHU Mechanical control AAW 10CM1FHU AAW 12CM1FHU AAW 18CM3FHU AAW 24CM3FHU Thank you very much for purchasing an Admiral Air Conditioner Please read this Use and Care Manual carefully before installing and using this appliance and keep this manual for future reference Muchas gracias por comprar un Aire Acondicionado Admiral Lea atentamente el Manual de Uso y Mantenimiento antes de instalar y utilizar este producto Conserve este manual para consultarlo en el futuro Forservices call 1877 465 3566 Para obtener servicio t cnico llame al 1877 465 3566 Table of Contents Page Introduction iii 2 Parts Identification aa 2 Electrical Specifications 4 Tips Before Installation A ea 5 Installation Instructions 6 Operating Instruciions es 41 Care and Maintenance a 15 Trouble Shooting Guide PI POE PO eee ee een ee eer eee ee eer S ene e nee 16 Warranty annie dejais polar cota 17 ndice P gina Introducci n A 18 Identificaci n de las Piezas 18 Especificaciones El ctricas 20 Consejos Antes de la Instalaci n 21 Instrucciones de Instalaci n uretra Es 22 Insiuedi nes de Operaci n snm 27 Cuidado y Mantenimiento o
7. Check fuse or circuit breaker Set FAN CONTROL to position other than OFF Inefficient or no cooling Dirty air filter Inappropriate capacity for application Blocked air flow Power interruption settings change too quickly or compressor overload tripped Clean or replace air filter Check with dealer to determine proper unit capacity for application Remove obstruction from grill or outdoor louvers Let fan run to restart compressor in approximately 10 minutes algae on wet surfaces Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Remove drain plug and drain base pan Replace drain plug Clean unit thoroughly Water dripping outside Condensation run off is normal during hot and humid weather Add flexible tubing to redirect water flow see Fig 14 Page 10 Water dripping inside Unit is not properly angled to allow water to drain outside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Ice or frost build up Low outside temperature Unit air filter is dirty When outdoor temperature is approximately 65 F or below frost may form when unit is in cooling mode Switch unit to FAN only operation until frost melts Remove and clean filter NOTE If circuit breaker is tripped repeatedly or fuse is bl
8. Inlet Vent Lever Power Cord Note The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Introduction Part Identification Remote control model Front Panel Cabinet i Control Panel Air Outlet p A A sd Air Filter Zam Sher T gt A Sol P Ho ae ee Ni A ius Mar SS E e a oe Interior et Air Inlet gt 3 ae Grille E a ai Fresh Air z Vent Lever Exterior Air Inlet Power Cord Remote Control gt Remote Control Control Panel Power Timer Note The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Electrical specifications 1 All wiring must comply with local and national electrical codes and must be installed by a l
9. de cada lado Los tornillo s que est n m s cerca del frente de la unidad sujetan el panel frontal al gabinete Los tornillos que est n m s cerca de la parte trasera de la unidad sujetan el gabinete al armaz n Vea la Fig 1 B Quite el panel frontal del gabinete tirando suavemente de l C Tome el mango que est en el frente del armaz n deslizable y saque con cuidado el aire acondicionado del gabinete Vea la Fig 2 NOTA una vezfinalizada la instalaci n en la ventana debe volver acolocar los tornillos para sujetar el armaz n deslizable Pida ayuda para realizar este procedimiento 3 Montaje de los canales superior e inferior en el gabinete A Canal Superior en Forma de L Aguante el doble sello adhesiva al canal superior en forma de L con 5tornillos de 1 4 instale el canal superior en forma de L sobreel gabinete tal como seindica en la Fig 3 B Instale el Canal Inferior en forma de U tal como seindica enla Fig 3 Nota Para los modelos de 18Ka 24K el canal de bot n se ha instalado en la f brica y su forma ser distinto a otros pero susfucciones son semejantes 4 Montaje de las persianas laterales cortinas en el gabinete Deslice las persianas porlos canales superior e inferior tal como se indica en la Fig 4 En cada marco las persianas se identifican como izquierda y derecha Sujete las persianas al gabinete con 4 tornillos de 1 4 de cada lado e o CLUE
10. of the unit should be outdoors and not in a garage nor inside of a building Keep unit as far away as possible from obstacles and obstructions and at least 30 above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow Window opening requirements see table below E Be certain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at proper current see table 1 on page 4 All wiring should be in accordance with local and national electrical codes F Your unit was designed to evaporate condensation under normal conditions However under extreme humidity conditions excess condensation may cause the basepan to overflow to the outside The unit should be installed where condensation run off cannot drip on pedestrians or neighboring properties Fence wall or other obstacle Side obstruction Ground Fig B Size Model 10K 12K 18 24K Cabinet size wp 205148 23 1 22 8 15 7 24 1 26 5 18 5 26 9 Min Window 24 opening 27 30 Max Window i 38 opening 41 44 Installation instructions 2 Preparation to Remove the Air Conditioner Slide Out Chassis A Remove total of 4 Philips screws securing the chassis to the cabinet There are 2 screws on each side The set of screws closest to the front of the unit secur
11. the cabinet to the bracket using 3 1 4 screws provided Repeat the Same procedure on the opposite side of the cabinet See Fig 10 B Ensure the L shaped mounting channel is positioned in front of the sash The bottom channel of the cabinet should be positioned in the track provided on the bracket assembly Pull the window Fig 10 down until it rests just behind the front of the L gt shaped mounting channel See Fig 11 Window Sash C Check to make sure that the cabinet is slanted slightly downward on the outside If necessary A re adjust support bracket as shown in Fig 7 fA 7 Secure Shutters ire ag j Channel A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the cabinet Fig 11 See Fig 12 Secure the top of the frames to the window sash with 2 3 4 screws 3 4 screws C Now secure bottom frame of shutters using one shutter clamp and one 3 4 screw on each side Fig 12 8 Reinstalling Front Panel Assembly A Position the front panel on the cabinet starting at the top The front panel lock tabs must be inserted into the retaining slots in the cabinet Repeat this procedure on all sides vo
12. time to turn on the unit If you wantto cancel ON TIMER press TIMER button A V Button Used to set room temperature in COOLING mode or used to set time in TIMER mode If the two keys are pressed at the same time the temperature LED display will alternate between C and F NOTE Temperature setting range is from19 C 66 F to 31 C 88 F Operating Instructions gt Remote control Power BUTTON The appliance will be started when it is energized or will be stopped when it is e e in operation if you press this button Power Timer e o Mode BUTTON Mode Power Saver Used to select the operation mode BUTTONS Used to set room temperature in Cooling mode or used to set time in Timer mode QO OO 90900 VS lt D lt High BUTTON ES Used to select the high fan speed mode Mid BUTTON Used to select the Mid fan speed mode Low BUTTON Used to select the Low fan speed mode Auto BUTTON Used to select the Auto fan speed mode Timer BUTTON Used to set or cancel timer operation Power Saver BUTTON Used to select the Energy saving mode 90 9290 OO OO When changing modes during operation sometimes the unit does not always respond at once Wait 3 minutes Wait 3 minutes before restarting the appliance Operating Instructions gt Remote control e How to Insert the Batteries Remove the battery cover according to the arrow direction Insert new
13. 31 Gu a para la Soluci n de Problemas emerge 32 CTO ee ee 33 Introduction Thank you for choosing this room air conditioner to cool your home This USE AND CARE MANUAL provides information necessary for the proper care and maintenance of your new room air conditioner If properly maintained your air conditioner will give you many years of trouble free operation To avoid installation difficulties read instructions completely before starting This manual contains information for the installation and operation of your room air conditioner Part Identification gt Mechanical control model Front Panel Cabinet Control Knob Air Outlet eee e ia Air Filter ee ee ee tet OS A O Z o SZ a ee i E gt Interior f Z ey i gt eee na Grille a JA 3 TE A Exterior Fresh Air Air
14. LY S lo ventilador ENERGY SAVING Ahorro de Energ a COOLING Enfriamiento Modelo WITH HEATER COOLING Enfriamiento FAN ONLY S lo ventilador HEATING Calefacci n ENERGY Indication symbols of LED on control panel SAVING Ahorro de Energ a COOLING Enfriamiento Ventilador en 3k Enfriamiento velocidad autom tica j A Ventilador en a A S lo ventilador NOTA Despu s de seleccionar un nivel espere 3 velocidad baja E Ventilador en Temporizador velocidad media 9 Ventilador en minutos antes de pasara otro Con el modo de FAN ONLY El recinto de la temperatura Dehabitaci n ser Desde 0 C 32 F hasta 38 C 99 F La temperatura de la habitaci n es superior a32 F E Ahorro de energ a la temperatura lucer LO VE OCCA Calg Calefacci n La temperatura de la habitaci n es superior a 99 F 71 170 F Mostrar temperatura fijada la temperatura lucer H1 LHR Mostrar hora programada Las luces del indicador LED anteriormente Boton Fan Speed Velocidad del Ventilador mencionadas se encienden cuando se usan los Se utiliza para seleccionar la velocidad del ventilador Modos correspondientes en secuencia autom tica baja media y alta Bot n Timer Temporizador Se utiliza para programar o cancelar el funcionamiento del temporizador Cuando la unidad est en funcionamiento puede seleccionar OFF TIMER Apagar Temporizador Cuando la unidad est apagada puede seleccionar ON TIMER Encender Temporizador
15. UCC Lado derecho Tornillos Philips Fig 1 Serpentin X nal Mango wlll 0 Armazon a CCU Doble Sello Adhesiva Tomillo de1 4 Para modelos de 10K a 12K Para modelos de 18K to 24K instalado en la f brica Fig 3 Marco de la Persiana Tornillo de1 4 J Persiana A Derecha Instrucciones de instalaci n go 5 Instalaci n de los Soportes Horizontales y de VISTA SUPERIOR la Primera Tira Adhesiva Ranura eny P o o fe o O o o o o Selladora L_J O 6 0 0000 00 00 NOTA Existe una gran variedad de estilos de v entanas Porlo tanto es probable que se Soporte Ensamblado 90 Soportes en Escuadra a necesario modificar o mejorar su propia instalaci n Pernos del Soporte Tornillo de _ gt A Sujete el soporte horizontal alos soportes en Nivelaci n escuadra Fig 5 con 2 pernos de 1 1 2 Hay Fig 5 dos pernos por soporte Aseg relos con las 2 i arandelas de presi n de 1 4 y las 2 tuercas de 1 4 oe NO ajuste estos pernos de inmediato ya que es posible que sea necesario ajustar la distancia del soporte ensamblado dependiendo dela profun didad del umbral de la ventana Vea la Fig 7 Instale los dos tornillos de nivelaci n en los sop ortes en escuadra A modo de p
16. ad se puede conectar a un cortacircuito o fusible utilizado por otros dispositivos No obstante la suma de los amperios m ximos de todos los dispositivos conectados a dicho cortacircuito o fusible no deben exceder los amperios del mismo Si el r tulo del aire acondicionado indica 115 voltios y m s de 7 5 amperios debe tener su propio fusible o cortacircuito y no se deber conectar ning n otro dispositivo o unidad a dicho fusible o cortacircuito Para evitar lesiones f sicas desconecte el suministro de energ a de la unidad antes de instalarla o repararla 5 El r tulo de la unidad contiene datos el ctricos y t cnicos Dicho r tulo se encuentra en el lado derecho de la unidad Tipos de Recept culos y Fusibles Nota 10K 12K Cooling only incluido modelos AAW 10CR1FHU AAW 10CM1FHU AAW 12CR1FHU AAW 12CM1FHU incluido modelos AAW 18CR3FHU AAW 18CM3FHU incluido modelos AAW 10DR3FHU AAW 12DR3FHU incluido modelos AAW 24CR3FHU AAW 24CM3FHU incluido modelos AAW 18DR3FHU AAW 24DR3FHU 18K 10K 12K 24K 18K 24K Cooling only With heating Cooling only With heating wes Ns e sz MODEL 10K 12K 18K Cooling only 24K 18K 24K Cooling only 10K 12K With heating Cooling only With heating CAPACIDAD DE VOLTIOS 125 250 250 250 AMPERIOS 15 15 20 30 AMPERIOS ae ey ES TAMANO DEL FUSIBLE 15 15 20 30 Tabla 1 Consejos antes de la instalaci n gyo Su unidad de Aire Acon
17. batteries making sure that the and of battery are matched correctly Reattach the cover by sliding it back into position Note e Use 2 LR06 AA 1 5volt batteries Do not use rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim If the replacement is done within 1 minute the remote control will keep original presetting This function only for LCD remote control Fee e How to Use To operate the room air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 23 feet when pointing at signal receptor of unit UCC UCC Signal receptor Care and Maintenance When servicing the air conditioner be sure to turn the mode switch to the OFF position and disconnect the power cord from the electrical outlet 1 DO NOT use gasoline benzine thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts 2 Never attempt to pour water directly in front of the unit as this will cause deterioration of the electrical insulation Cleaning the Air Filter Removal of Air Filter If the air filter becomes clogged with dust air flow is obstructed and reduces efficiency The air filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and ind
18. culate the air at a middle speed without cooling HIGH FAN will circulate the air at a maximum speed without cooling LOW COOL provides cooling automatically with minimum air circulation Recommended for night time use MED COOL provides cooling automatically with middle air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL OFF will completely shut off the unit NOTE After setting the mode allow 3 minutes before switching to another mode Fresh Air Ventilation is usually kept in the closed position Use only when clearing smoke and or odors from the room Pull to open 11 THERMOSTAT Thermostat Mode knob knob Fig 15 A CAUTION A When using FAN control turn slowly allowing unit to adjust When using THERMOSTAT be sure to allow three minutes before changing temperature Adjusting too quickly may cause an overload resulting in a blown fuse ee CCC CCC 6 Fresh Air Vent Lever Fig 16 Operating Instructions gt Electronic control panel model Control Panel You can easily operate this air conditioner by pressing relevant button on the control panel as well as the remote control Button The air conditioner will be started when it is energized or will be stopped when it
19. curtains or shades to keep direct sunlight from heating your room but DO NOT obstruct the air conditioner Allow air to circulate around the unit without obstructions 4 Start your air conditioner before outdoor air becomes hot cold and uncomfortable This avoids an initial period of discomfort while the unit is cooling or heating off the room 5 When outdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting Your Room Air Conditioner was designed for easy installation in a single or double hung window NOTE This unit is NOT designed for vertical slider type windows A CAUTION A To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of the hardware kit against the corresponding model check list prior to installation of the unit See lists below Fig A Fig A Installation Hardware gt 3 4 Screws 10 Shutter Clamp 2 Ss 1 4 Screws 23 Washer 10 A Top Channel 1 Side Curtain RH 1 Bottom Channel 1 For 10K to 12K models 98 Curtain LH 1 Bottom Channel 1 For 18K to 24K models Factory Installed Q Lock Washers 4 1 1 2 x1 4 Bolts 4 Sy Seal 1 1 4 Nuts 4 A aaa O Foam 1
20. dad de ventilador Bot n Low Para ajustar el modo baja velocidad de ventilador Bot n Auto Para ajustar el modo auto velocidad de ventilador Bot n Timer Temporizador Para ponero cancelar la operaci n de timer O O O O9 O Bot n Power Saver Para ajustar el modo de energia ahorro Despu s de seleccionar un nivel espere 3 minutos antes de pasar a otro Espere 3 minutos antes de recomenzar el aparato Instrucciones de Operaci n gonn Control remoto e Colocai n de las pilas Retire la tapa de las en el sentido de la flecha Introduzca las pilas nuevas con cuidado de que coincidan los polos y Vuelva a instalar la tapa desliz ndola otra vez a su posici n Nota e Utilice pilas 2 LR6 AA 1 5V No utilice pilas recargables Sustituya las pilas por otras nuevas del mismo tipo cuando la pantalla aparezca atenuada Si la sustituci n se realiza en el plazo de 1 minuto el mando a distancia conservar los valores prefijados oridinales Este funci n es s lo para controlador remoto de LCD e C c mo use Para operar el aire acondicionado apunte el controlador remoto la se ar del receptor El controlador remoto sera aoperar el aire acondiciondo con una diatancia hasta 23 pies cuando apunta a la se ar del receptor de la unidad CU CCC Receptor de senal Cuidado y Mantenimiento Cuando repare el aire acondicionado asegurese de colocar la peril
21. dad NO se ha disenado para ventanas verticales de tipo deslizante A PRECAUCI N A Para evitar problemas durante la instalaci n o el funcionamiento de la unidad lea completamente las instrucciones NOTA conserve la caja de la unidad y los materiales de empaque para almacenarla o transportarla en el futuro Antes de instalar la unidad compare el contenido del juego de herrajes con la lista de control del modelo correspondiente Consulte las siguientes listas Fig 1 Herrajes de Instalaci n Tornillos de 3 4 10 Grapa de Persiana 2 Tornillos de 1 4 23 A Canal Superior 1 Junta de Culata 10 m Canal Inferior 1 10K 12K Cortina Lateral Derecha 1 Cortina Lateral Izquierda 1 i S Sello 1 Doble Sello Adhesiva 1 S Espuma 1 Fig 1 Nota Tornillo Excedente Para d Uso de Reserva Canal Inferior 1 18K 24K E instalado en la f brica Q Arandelas de Presi n 4 Pernos de1 1 2 x1 4 4 Tuercas de1 4 4 o o o OF oO O O Oo OO O o oogoovooogoooo Soportes Horizontales 2 Soportes en Escuadra 2 A oom TapaTrasera y Patas de Nivelaci n 2 Herramientas Necesarias para la Instalaci n en Ventana Destornilladores Philips y de cabeza plana Taladro el ctrico broca de 1 8 pulgada de di metro L piz Cinta m trica Tijeras Nivel de car
22. dicionado para Habitaciones se ha dise ado para lograr un alto rendimiento y ahorrar energ a el ctrica Siga las siguientes sugerencias para lograr un mayor rendimiento 1 Ajuste el termostato a un nivel que le resulte agradable y d jelo en el nivel seleccionado 2 El filtro de aire es muy eficiente a la hora de eliminar part culas que se desplazan por el aire Mantenga limpio el filtro de aire Por lo general el filtro deber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad del aire exterior o interior 3 Puede utilizar tapices cortinas o pantallas para evitar que la luz directa del sol caliente su habitaci n pero NO obstruya el aire acondicionado Permita que el aire circule alrededor de la unidad sin obstrucciones 4 Encienda el aire acondicionado antes de que la temperatura exterior sea demasiado elevada y desagradable De esta manera evitar sufrir calor mientras la unidad enfr a la habitaci n 5 Cuando la temperatura exterior es lo suficientemente fresca utilice s lo HIGH FAN ventilador al m ximo o LOW FAN ventilador al m nimo Esto hace que el aire interior circule a una temperatura agradable y consume menos energ a el ctrica que si hiciera funcionar la unidad como enfriador de aire El Aire Acondicionado para Habitaciones se ha disenado de modo tal que resulte f cil su instalaci n en ventanas armadas sencillas o dobles NOTA esta uni
23. e the front panel to the cabinet The set of screw closest to the rear of the unit secure the cabinet to the chassis See Fig 1 B Remove the front panel assembly from the cabinet by gently pulling it C Grasp the pull handle at the front of the slide out chassis and carefully slide the air conditioner out of the cabinet See Fig 2 Please seek assistance for this procedure NOTE Screws must be reinstalled upon completion of the window installation to secure slide out chassis 3 Assembly of the upper amp lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to the L shaped top channel and then Install the L shaped top channel to the cabinet as shown in Fig 3 using 5 1 4 screws B n Shaped Bottom Channel installed as shown in Fig 3 using 4 1 4 screws NOTE For 18K to 24K models the bottom channel has been factory installed and their shapes may differ from the others but their functions are similar 4 Assembly of the side shutters curtains to the cabinet Slide the shutters into the top and bottom channels as shown in Fig 4 The shutters are identified on each frame as left amp right Attach the shutters to the cabinet using 4 1 4 screws on each side CLU UCC Right side Philips screws Fig 1 Coil SS M Chassis my Pull Handle
24. erial plate rating of 230 volts it must have its own fuse or circuit breaker and no other device or unit should be operated on the fuse or circuit breaker To avoid the possibility of personal injury disconnect power to the unit before installing or servicing RECEPTACLE AND FUSE TYPES 10K 12K 18K Cooling only 24K 18K 24K COOLING CAPACITY Cooling only 40K 12K With heating Cooling only With heating RATED VOLTS 125 250 250 AMPS 15 20 30 WALL OUTLET ay ey EN FUSE SIZE 15 20 30 Table 1 Note 10K 12K Cooling only including models AAW 10CR1FHU AAW 10CM1FHU AAW 12CR1FHU AAW 12CM1FHU 18K 10K 12K 24K 18K 24K OS a OS a A Cooling only including models AAW 18CR3FHU AAW 18CM3FHU With heating including models AAW 10DR3FHU AAW 12DR3FHU Cooling only including models AAW 24CR3FHU AAW 24CM3FHU With heating including models AAW 18DR3FHU AAW 24DR3FHU Tips before installation Your Room Air Conditioner unit is designed to be highly efficient and save energy Follow these recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting 2 The air filter is very efficient in removing airborne particles Keep the air filter clean Typically the filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality 3 Use drapes
25. erior delos marcos al marco de la ventana con 2 tornillos de 3 4 C Ahora asegure el marco inferior de las persianas con una grapa y un tornillo de 3 4 de cada lado Fig 12 8 Como Volver a Instalar el Panel Frontal A Coloque el panelfrontal en el gabinete comenzando por la parte de arriba Las trabas del panel frontal deben insertarse en las ranuras de sujeci n del gabinete Repita este procedimiento de todoslos lados B Asegure la rejilla frontal al gabinete con los tornillos Philips que quit anteriormente Fig 1 Fig 10 Marco de laVentana Canal de Sello Montaje en Forma de L Fig 11 Tomillo de3 4 a Serpentin To Canalde Sello Montaje en Forma de L rnillo deSeguridad Fig 12 Instrucciones de instalaci n go 9 Finalice la instalaci n A Corte la espuma para que quepa en la abertura A entre la parte superior del interior y exterior de la Wa ventana Vea la Fig 13 a Espuma B Es probable que algunas instalaciones necesiten Wa tira selladora adicional alrededor de la ventana y el aire acondicionado Verifique si hay alguna p rdida a de aire y s llela sies necesario C Enzonas de mucha humedad es posible que la descar
26. ffairs office or your state s Attorney General Gracias por elegir este aire acondicionado para enfriar su hogar Este MANUAL DE USO Y MANTENIMIENTO proporciona la informaci n necesaria para cuidar y mantener en forma adecuada su nuevo aire acondicionado Funcionar sin problemas durante muchos a os si le brinda el mantenimiento apropiado Para evitar problemas al instalarlo lea completamente las instrucciones antes de comenzar Este manual contiene informaci n acerca de la instalaci n y el funcionamiento del aire acondicionado para habitaciones Identificaci n de las Piezas gt Modelo Mec nico Entrada de Tirador Controlado Aire Interior Panel Frontal Gabinete Aire Interior aoa E heed Filtro de Aire en elinterior 2 f as o o Rejilla de i se e Entrada d t a n CORNS Se
27. ga de agua haga que la unidad desborde o que el aire acondicionado haga m s ruido Si esto sucede puede acoplar una manguera de desagiie no incluida al tap n de drenaje para que las condensaciones se descarguen bien Vea la Fig 14 Manguera de Desagiie no incluida Instrucciones de Operacion MODE Modo La perilla de modo controla las velocidades de ventilador y de enfriamiento Para fijar una temperatura de enfriamiento simplemente haga rotar la perilla y col quela en el nivel deseado Vea la Fig 15 THERMOSTAT Termostato El termostato controla autom ticamente el ciclo de enfriamiento compresor del aire acondicionado para mantener la temperatura del ambiente No obstante el motor del ventilador continuar funcionando una vez finalizado el funcionamiento del compresor ciclo de enfriamiento Vea la Fig 15 LOW FAN Ventilador al M nimo har que el aire circule a una velocidad m nima sin enfriar MED FAN Ventilador al Mediano har que el aire circule a una velocidad mediana sin enfriar HIGH FAN Ventilador al M ximo har que el aire circule a una velocidad m xima sin enfriar LOW COOL Fr o M nimo enfr a el ambiente autom ticamente con una circulaci n minima de aire Se recomienda durante la noche MED COOL Fr o Mediano enfr a el ambiente autom ticamente con una circulaci n mediana de aire Se recomienda durante la noche HIGH COOL Frio M ximo enfr a el amb
28. icenced electrician If you have any questions regarding the following instructions contact a licenced electrician 2 Check available power supply and resolve any wiring problems BEFORE installing and operating this unit 3 For your safety and protection this unit is grounded through the power cord when plugged into a matching wall outlet If you are not sure whether your wall outlet is properly grounded please consult a licenced electrician 4 The wall outlet 3 pin must match the plug 3 pin on the power cord supplied with the unit DO NOT use plug adapters or extension cords See Table 1 for receptacle and fuse information 5 The rating plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit Make sure to use the correct power supply according to the rating plate of your air conditioner Ly Electric Shock Hazard A If the air conditioner has a serial plate rating of 115 volts and up to and including 7 5 amps the unit maybe on a fuse or circuit breaker with other devices However the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker If the air conditioner has a serial plate rating of 115 volts and greater than 7 5 amps it must have its own fuse or circuit breaker and no other device or unit should be operated on the fuse or circuit breaker If the air conditioner has a s
29. iente autom ticamente de manera r pida o durante d as de calor intenso Una vez que la habitaci n est fr a reduzca el nivel a LOW COOL OFF Apagado apaga la unidad completamente Ventilaci n de aire fresco se ra a mantener en la posici n cerrado Usando s lo para limpiar humos y o odores de la habitaci n tire a comenzar Vea la Fig 16 THERMOSTAT Perilla de Perilla de termostato modo Fig 15 A PRECAUCION A Cuando utilice la perilla de control de ventilador h gala girar lentamente para permitir que la unidad se adapte al nivel Cuando utilice THERMOSTAT aseg rese de esperar tres minutos antes de cambiar la temperatura Si la cambia demasiado r pido es posible que cause una sobrecarga y se queme el fusible o CLU UCC Palanca de aire fresco Fig 16 Instrucciones de Operacion Este aire acondicionado se puede operar facilmen te con los botones del panel de control asicomo Panel de Control tambi n con el control remoto Airconditioner Bot n tb Encendido Apagado Si presiona este bot n encenderdel aire acondicionado Cuando elaire acondicionado esta de calefacci n se per imprentar este bot n 3 minutos despu s Timer A Fan Speed Mode Boton Mode Modo Cada vez que se presiona el bot n MODE el modo de operaci n cambia en estas secuencias Modelo COOLING ONLY COOLING Enfriamiento FAN ON
30. interrumpe la corriente varias veces o el fusible se quema m s de una vez comun quese con un t cnico licenciado GARANTIA GARANTIA COMPLETADE 5ANOS Este producto se garantiza por 5 anos a partir de la fecha de la compra original Cualquier parte que falle en materiales o la ejecuci n ser substituida dentro del per odo de la garant a Esta garantia incluye servicio a domicilio Una copia desu prueba de la compra con la fecha dela compra del producto incluida se requiere para acordar esta reparaci n del servicio Para el nombre y la localizaci n de un prestador de servicio autorizado lo m s cerca posible a usted llame porfavor al 1 877 465 3566 Refi rase porfavor al nombre del producto ala marca y al n mero de modelo cuando usted llama Esta garant a nose aplica si el da o ocurre debido a accidente manejo u operaci n incorrectos danos de transporte abuso uso err neo reparacion no autorizada el uso comercial del producto utro uso para el cual no fuera pensado TODAS LAS GARANT AS EXPRESADAS O IMPLICADAS DURAN POR5ANOS APARTIR DELA FECHA DE LACOMPRA ORIGINAL ESTA GARANTIA NO CUBRE LA RESPONSABILIDAD PORLOS DANOS FORTUITOS O CONSECUENTES PARA CUALESQUIER CAUSA EN NINGUNCASO Esta garant a se extiende al due o original y a cualquier due o subsiquiente para los productos comprados para el uso casero dentro de los E E U U Algunos estados no permiten la exclusi n o la limitaci n de danos fortuitos o con
31. is in operation if you press this button When the air conditioner is heating allow 3 minutes after you press this button Mode button Each time MODE button is pressed the operation mode is changed in sequence COOL COOLING gt FAN ONLY ENERGY SAVING COOLING HEAT COOLING gt FAN ONLY HEATING ENERGY SAVING TEURER Indication symbols of LED on control panel NOTE After setting the mode allow 3 minutes before switching to another mode y Auto fan speed 3 Cooling a In the FAN ONLY Mode Room Temperature display range cI cI E is from 0C 32F to 38 C 99F J Low fan speed A tm Room Temperature below 32 the Temperature display LO e medium fan speed 38 Heating SPY Set timer Room Temperature above 99 F the Temperature display H1 High fan speed E Energy saving Fan Speed button Used to select fan speed in sequence auto low Timer medium and high Above LED lights on when the relevant mode is in used Timer button Used to set or cancel timer operation When the unit is in operation you can set OFF TIMER When the unit is off you can set ON TIMER Timer setting range is O to 24 hours If the OFF TIMER is set the timer LED displays the remaining time to turn off the unit for only 12 seconds then LED shifts to display set temperature If you press TIMER button within the 12 seconds OFF TIMER will be canceled If the ON TIMER is set the timer LED displays the remaining
32. la de modo en OFF y luego desconectar el cable de alimentaci n del tomacorriente el ctrico 1 NO utilice gasolina bencina disolvente u otros productos quimicos en el aire acondicionado ya que estas sustancias pueden danar el acabado de pintura y deformar las piezas de pl stico 2 Nunca derrame agua directamente en el frente de la unidad ya que danar a el aislamiento el ctrico Limpieza del Filtro de Aire Extracci n del Filtro de Aire Si el filtro de aire se obstruye con polvo el flujo de aire queda obstruido y reduce el rendimiento de la unidad El filtro de aire deber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad de aire exterior o interior C mo Quitar el Filtro de Aire IEI filtro de aire de los modelos anteriormente mencionados se encuentra detr s de la rejilla de entrada de aire delantera Para quitarlo tome el mango del filtro ubicado enla parte superior de la rejilla de entrada de aire y desl celo hacia arriba Para volver a instalarlo realice los procedimientos anteriores a la inversa A CAUTION A NO olvide instalar el filtro de aire Si el aire acondicionado funciona sin el filtro de aire el polvo no se puede eliminar de la habitaci n y es posible que la unidad se descomponga Cuando la rejilla de entrada de aire y el gabinete est n sucios l mpielos con agua templada por debaj de los 104 F Se recomienda el uso de un de
33. limentaci n Panel de Control Control Remoto Airconditioner Nota Las im genes de este manual est n basadas en la vista externa de un modelo est ndar En consecuencia es probable que la forma sea diferente ala del aire acondicionado que usted seleccion 19 Especificaciones el ctricas goon 1 Todos los cables deben cumplir con los c digos el ctricos locales y nacionales y los debe instalar un electricista licenciado Si tiene preguntas relacionadas con las siguientes instrucciones comun quese con un electricista licenciado 2 Verifique el suministro de energ a disponible y resuelva cualquier problema con los cables ANTES de instalar y hacer funcionar esta unidad 3 Para su seguridad y protecci n esta unidad est conectada a tierra a trav s del cable de alimentaci n cuando se lo enchufa a un tomacorriente de pared provisto de conexi n a tierra Si no est seguro de que el tomacorriente de pared cuenta con la conexi n a tierra apropiada consulte con un electricista licenciado 4 El tomacorriente de pared de 3 clavijas debe coincidir con el enchufe de 3 clavijas del cable de alimentaci n suministrado con la unidad NO utilice adaptadores de enchufe ni cables de extensi n Consulte la Tabla 1 para obtener informaci n acerca de recept culos y fusibles Ly Peligro de Descarga El ctrica A Si el r tulo del aire acondicionado indica 115 voltios y hasta 7 5 amperios la unid
34. n L Shaped Seal Mounting Channel Security Screw B Secure the front grille to the cabinet using the Philips screws removed earlier Fig 1 Fig 12 Installation instructions 9 Complete the installation A Cut the foam to fit the opening between the top of e the inside and outside window See Fig 13 Y de ll L a ve A B Some installations may require additional sealing around the window and air conditioner Check for any We air leaks and seal where necessary Fig 13 C In very humid areas the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations to run off conveniently See Fig 14 w Drain Hose not included Operating Instructions Mechanical control model MODE The mode knob controls fan speeds and cooling speeds To set desired cooling temperature simply rotate the mode knob dial to the appropriate setting THERMOSTAT The thermostat automatically controls the cooling cycle compressor of the air conditioner to maintain room temperature However the fan motor will continue to operate after the compressor cooling cycle is completed LOW FAN will circulate the air at a minimum speed without cooling MED FAN will cir
35. nced too far away from the wall to provide stability it may be necessary for you to fill ia this area with a solid piece of wood See Fig 8 4 2 3 4 screws per bracket o AA J oodooooQooo o B Measure the inside window sill width and find the E 3 16 Maximum center as shown in Fig 6 Align the V slot in each ty bracket on these marks and mount the brackets to the sill using 3 4 screws provided Brackets should be Leveling Screw perpendicular to the inside window sill See Fig 6 lt os C For proper condensation run off it will be necessary Fig 7 to adjust the angle pitch of the window brackets This is accomplished by adjusting the distance of the leveling i E EEN screw on the outer wall The maximum angle pitch should not exceed more than 3 16 See Fig 7 lt q Solid Piece Wood If required D Cut the seal strip to fit the underside of the bottom window sash Remove the peel off backing on the seal and attach it to this sash See Fig 9 Fig 8 AA A CAUTI O N A Window Sash Use a solid piece of wood to provide stability This will be required when sills are extra deep Window i a See Fig 8 dal Fig 9 Installation instructions 6 Installation of the cabinet A Align one hole in the bottom of the cabinet with one hole in the bracket assembly Secure
36. oor air quality Air Filter Removal The air filter on the above model is located behind the air intake front grill To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure dh CAUTION A DO NOT forget to install the air filter If the air conditioner is left to operate without the air filter dust is not removed from the room and may cause your air conditioner to fail When the air filter inlet grill and cabinet are dirty wipe with lukewarm water below 40 C 104 F Use of mild detergent is recommended Cleaning of Air Filter 1 Remove dust clogged in the filter by tapping it or vacuum clean it 2 Wash the filter well with lukewarm water below 40 C 104 F while rubbing lightly To get better results wash it with soapy water or a neutral cleaning agent 3 Rinse the filter well using clean water then dry completely End of Season Care 1 Operate the fan alone for half a day to dry out the inside of the unit 2 Turn off power and remove plug from wall socket 3 Clean filter 4 Store in a dry location Troubleshooting Guide Frequently a problem is minor and a service call may not be necessary use this troubleshooting guide for a possible solution PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will not operate No power to the unit Check connection of power cord to power source
37. own more than once contact a licensed technician Warany_ 5 YEARFULL WARRANTY This product is warranted for 5 years from the date of original purchase Any part which fails in materials or workmanship will be replaced within the warranty period This warranty covers inhome service Acopy of your proof of purchase with date of purchase and product name included is required to arrange this service repair For the name and location of an authorized service provider nearest you please CALL 1 877 465 3566 Please reference product name brand name and model number when you call This warranty does not apply if the damage occurs because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted or the use of the product for commercial use or any other use for which it was not intended ALL WARRANTIES EXPRESSED OR IMPLIED LAST FOR 5 YEARS FROM THE DATE OF ORIGINAL PURCHASE THIS WARRANTY DOES NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER This warranty is extended to the original owner and any succeeding owner for products purchased for home use within the USA Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific rights and you may also have other rights which may vary from state to state To know what your legal rights are consult your local or state consumer a
38. pintero Instrucciones de Instalaci n Jo A PRECAUCIN A Debido a que el compresor se encuentra del lado de los controles a la derecha de la unidad este lado ser m s pesado y m s dif cil de manipular Si la unidad no se sostiene bien de dicho lado pueden producirse lesiones f sicas y da os a la unidad y a su propiedad Por lo tanto le recomendamos que para instalar esta unidad solicite ayuda a otras personas 1 Seleccione la Mejor Ubicaci n A El aire acondicionado para habitaciones tiene un dise o que facilita su colocaci n en ventanas armadas sencillas o dobles No obstante debido a que los dise os de ventana son tan variados es probable que sea necesario realizar algunas modificaciones para lograr una instalaci n segura y adecuada B Aseg rese de que la ventana y el marco tengan una estructura firme y que la madera no est rajada ni podrida C Para lograr el m ximo rendimiento instale el aire acondicionado del lado de la casa o edificio donde haya m s sombra que sol Si la unidad se encontrara expuesta a la luz del sol es aconsejable colocarle un toldo encima D Deje suficiente espacio alrededor del gabinete para permitir una amplia circulaci n de aire a trav s de la unidad Vea Fig 2 La parte posterior de la unidad deber dar al aire libre y no a un garaje ni al interior de un edificio Mantenga la unidad lo m s lejos posible de obst culos que puedan causar obstrucciones y po
39. r lo menos a 30 del nivel del piso o del suelo Deber n tomarse precauciones para evitar que las cortinas o cualquier otro objeto dentro de una habitaci n obstruyan el flujo de aire E Aseg rese de instalar la unidad cerca de un tomacorriente el ctrico adecuado Utilice un estime al corriente propio lea tabla 1 en p gina 20 con circuito exclusivo para el aire acondicionado Todos los cables deber n cumplir con los c digos el ctricos locales y nacionales F La unidad est disenada para evaporar la condensaci n bajo condiciones normales No obstante bajo condiciones de extrema humedad es probable que la condensaci n excesiva haga que la bandeja base se desborde hacia el exterior Por lo tanto la unidad deber instalarse en un lugar donde la descarga de la condensaci n no gotee sobre el paso de peatones ni en las propiedades vecinas Cerca ae pared u Min Obstrucci n SU IA otro lateral obst culo Suelo Fig 2 Requisitos para las aberturas de ventanas consulte la siguiente tabla Modelo Tama o 10K 12K 18 24K Tamaito del gabinete 20 51 14 81 23 1 22 8 15 7 24 126 5 18 5 26 9 Abertura m nima 24 27 30 de Ventana Abertura m xima 38 41 44 de Ventana Instrucciones de instalaci n jj 2 C mo quitar el armaz n deslizable del aire acondicionado A Quite los 4 tornillos Philips que sujetan el armaz n al gabinete Hay 2 tornillos
40. rueba coloque s el soporte ensamblado en la ventana antes de Medida para elModelo 10K 9 6 Centro Umbral de la Ventana i i i ig Medida para elModelo 12K 10 3 instalar el gabinete Silos tornillos de nivelaci n Medida para elModelo 18K 24K 12 6 est n demasiado lejos dela pared como para proporcionar estabilidad es probable que sea Fig 6 necesario complementar dicha rea con un taco T de madera Veala Fig 8 foe 00000900000 E M ximo de 3 16 B Mida el ancho del interior del umbral de la ventana y defina el centro tal como se indica en la Fig 6 Alinee la ranura en V de cada soporte ensamblado sobre estas marcas y monte los Soporte en Escuadra Tornillo de Nivelaci n soportes al umbral con los tornillos de 3 4 PAGE ena proporcionados Los soportes deber n quedar perpendiculares al umbral interno de la ventana Fig 7 Veala Fig 6 C Parapermitir unadescarga adecuadade lac _ eo eo oo GOO OOOO ondensaci n ser necesario ajustar la inclinaci n de los soportes en la ventana Para ello ajuste la distancia del tornillo de nivelaci n en la pared exterior La inclinaci n m xima no deber ser superior a3 16 Vea la Fig 7 XY lt 441 1_ Taco deMadera si es necesario D Corte la primera sello para que quepa en la parte inferior del marco de la ventana Quite el
41. secuentes Esta garant a le da las derecho espec ficos y usted puede tambi n tener otras erechos que puedan variar de estado a estado Para saber cu les son sus derechas legales consulte asu oficina local del consumidor oa la procuraduria de su estado 2002 2005 Kelon Air Conditioner company and Kelon USA Inc All rights reserved Printed in China Version No 819041944 1
42. sor Limpie o reemplace el filtro de aire Hable con el representante para determinar cu l es la capacidad adecuada para la aplicaci n Quite toda obstrucci n de la rejilla o de las persianas exteriores Haga funcionar el ventilador para reiniciar el compresor en aproximadamente 10 minutos Unidad ruidosa Piezas sueltas Soporte inadecuado Ajuste las piezas sueltas Proporcione soporte adicional a la unidad Olores Formaci n de moho u hongos sobre las superficies h medas Quite el tap n de drenaje y la bandeja base Cambie el tap n de drenaje Limpie la unidad en forma completa Gotea agua afuera Es normal la descarga de condensaci n cuando el clima es c lido y h medo Utilice tuber as flexibles para desviar el flujo de agua Gotea agua adentro La unidad no est bien inclina da como para permitir el desagie externo La unidad debe instalarse con un ligero desnivel para permitir una descarga adecuada de la condensaci n Verifique la unidad y realice los ajustes necesarios Se forma hielo o Baja temperatura exterior Cuando la temperatura exterior sea inferior a los 65 F es posible que se forme escarcha si escarcha la unidad funciona en modo de enfriamiento Cambie el funcionamiento de la unidad a FAN solamente hasta que la escarcha se derrita El filtro de aire de la unidad Quite el filtro y limpielo est sucio NOTA Si el cortacircuito
43. tergente suave Limpieza del Filtro de Aire 1 Elimine el polvo acumulado en el filtro Para ello apl quele unos golpes suaves o una aspiradora dom stica 2 Lave bien el filtro con agua templada de temperatura inferior a los 40 C 104 F mientras lo frota suavemente Para obtener mejores resultados lavelo con agua jabonosa o con un producto de limpieza neutro 3 Enjuague bien el filtro con agua limpia y luego s quelo completamente Cuidado de Fin de Temporada 1 Haga funcionar el ventilador durante medio d a para que se seque el interior de la unidad 2 Ap guelo y desench felo del tomacorriente de pared 3 Limpie el filtro 4 Almac nelo en un lugar seco e Gu a para la Soluci n de Problemas Generalmente los problemas son sencillos yes probable que no sea necesario llamar a un t cnico Esta gu a puede ayudarlo a resolverlos PROBLEMA CAUSA POSIBLE SOLUCI N SUGERIDA El aire acondicionado no funciona La unidad no recibe suministro el ctrico Verifique si el cable de alimentaci n e staconectado al tomacorriente Verifique el fusible o el cortacircuito Fije el FAN CONTROL control del ventilador en una posici n que no sea OFF Enfr a poco o nada Filtro de aire sucio Capacidad inadecuada para la aplicaci n Flujo de aire obstruido Corte de energ a el ctrica se cambi de nivel demasiado r pido o se dispar el interruptor por sobrecarga del compre
Download Pdf Manuals
Related Search
Related Contents
Software Guide.fm Scrivener 1.8 for Microsoft Windows Samsung 23.6英寸全高清 网吧专供入门显示器 用户手册 MD Building Products 70243 Installation Guide : Free Download, Borrow, and Streaming : Internet Archive lin. - Actaf T r o m m e l - m o T o r e n L`être humain, une question de détails Un ouvrage de M. Albert Piette Samsung SC62J0 Brugervejledning (Windows 7) SRD991 Pozycjoner inteligentny Copyright © All rights reserved.
Failed to retrieve file