Contents

1. Cabinet Control Panel Air Outlet e A 2 ae a lt AA han ae ae aa ae Sy Z ETE O eo os ae oo gt o octet cell O So PS E E X eee E E I yen TE 3 Exterior Air Inlet Fresh Air Vent Lever Power Cord Control Panel Remote Control A i o Ae o Y YO Do Y Co S A The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 6 AIR CONDITIONER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the SAFETY ALERT SYMBOL This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean A DAMN G E R You can be killed or seriously inured if you don t immediately follow instructions You
2. Air Filter RR RR PRA SII 7K iS RRR RADIKAL III PX RRA LS KKK OK NGA X IRRIA RBA e RR REO a SERA a A Ke KOK PKK RIK IY PHI NOK neces ZLA N PEK KY KKK IN ILIRIK KOKA RR PR PO ANA PR RI III code OX RX ex xx CARR AR PR A o IA 10 KX b xX ROA ARI DO RARA DORR Interior Air Inlet Grille UC Exterior Air Inlet Fresh Air Vent Lever Power Cord Note The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 5 INTRODUCTION PART IDENTIFICATION gt Remote control model Front Panel Air Filter Interior Air Inlet Grille Airconditioner Note
3. Marco de la Ventana E Sello Fig 9 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page at Instrucciones de Instalacion 6 Instalaci n del gabinete A Alinee un agujero de la parte inferior del gabinete con un agujero del soporte ensambla do Sujete el gabinete al soporte ensamblado con 3de los tornillos de 1 4 proporcionados Repita el mismo procedimiento del otro lado del gabinete Vea la Fig 10 B Aseg rese de que el canal de montaje en forma de L est delante del marco El canal en forma de U dela parte inferior del gabinete de ber quedar en el riel del soporte ensamblado Baje la ventana hasta que apoye justo detr s de la parte delantera del canal de montaje en forma de L Vea la Fig 11 Fig 10 C Aseg rese de que el gabinete est levemente inclinado hacia abajo en la parte externa Si es necesario vuelva a ajustar el soporte tal como se indica en la Fig 7 Marco de la Ventana 7 Asegurelas Persianas A Vuelvaa colocar con cuidado el aire acondicionado en el gabinete Pida ayuda para realizar este procedimiento Canal de Sello Montaje en Forma A de L B Vuelvaa instalarlos tornillos del armaz n deslizable que se quitaron anteriormente de ambos lados del gabinete Vea la Fig 12 Asegure la parte superior de los marcos al marco d
4. Measurement for Model 8K 7 5 Measurement for Model 10K 9 6 Window sill Measurement for Model 12K 10 3 Measurement for Model 15K to 24K 12 6 Fig 6 ge 2 3 4 screws per bracket 5o 00o o ooo Oooo o 4 3 16 Maximum Bracket Assembly Leveling Screw lt 4 Outer Wall Construction Fig 7 y 008 0 6 OO DEEN 4 Solid Piece Wood If required Fig 8 LY Window Sash Window Sash x Sealing Strip T Fig 9 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 INSTALLATION INSTRUCTIONS 6 Installation of the cabinet A Align one hole in the bottom of the cabinet with one hole in the bracket assembly Secure the cabinet to the bracket using 3 1 4 screws provided Repeat the same procedure on the opposite side of the cabinet See Fig 10 B Ensure the L shaped mounting channel is positioned in front of the sash The U shaped bottom channel of the cabinet should be positioned in the track provided on the bracket assembly Pull the window down until it rests just behind the front of the L shaped mounting channel See Fig 11 Fig 10 Window Sash C Check to make sure that the cabinet is slanted slightly downward on the outside If necessary a re adjust support bracket as
5. WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 1 an ROOM AIR CONDITIONER Use and Care Manual nang AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento ENERGY STAR Remote control AAW 08CR1FHUE AAW 10CR1FHUE AAW 12CR1FHUE AAW 15CR1FHUE Do AAW 18CR3FHUE AAW 22CR3FHUE AAW 24CR3FHUE Mechanical control AAW 08CM1FHUE AAW 10CM1FHUE AAW 12CM1FHUE AAW 15CM1FHUE AAW 18CM3FHUE AAW 22CM3FHUE AAW 24CM3FHUE Thank you for purchasing an Admiral room air conditioner Please read this Use and Care Manual carefully before installing and using this appliance Keep this manual for future reference Muchase gracias por comprar un aire acondicionado Admiral Lea atentamente el Manual de Uso y Mantenimiento antes de instalar y utilizar este producto Conserve este manual para consultarlo en el futuro For Service Call 1 877 465 3566 Para obtener servicio t cnico llame al 1 877 465 3566 o WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 2 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 3 TABLE OF CONTENTS Page Introduction cerasrarnanenas rascar be ao ed aa 2 Parts Identification ooooooccccn ees 2 3 Air Conditioner Safety oooooococococcca eee 4 5 Electrical Specifications 0 ccc ee ee es 6 Tips Before Installation 0 ccc ees 7 Installation Instructions 1 0 ccc ee es 8 12 Operating Instructions 1 0 0 ee es 13 16
6. Double 3 Assembly of the upper 8 lower channels to Adhering seal the cabinet A L Shaped Top Channel Stick the double adhering seal to the L shaped top channel and then Install the L shaped top channel to the cabinet as shown in Fig 3 using 5 1 4 screws B n Shaped Bottom Channel installed as PO ea shown in Fig 3 using 4 1 4 screws 1 4 Screw NOTE For 15K to 24K models the bottom channel Fig 3 has been factory installed and their shapes may differ from the others but their functions are similar 4 Assembly of the side shutters ila curtains to the cabinet MEE Slide the shutters into the top and bottom Right Shutter channels as shown in Fig 4 The shutters are p identified on each frame as left amp right Attach 7 the shutters to the cabinet using 4 1 4 screws on each side WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 26 INSTALLATION INSTRUCTIONS 5 Installation of Mounting Brackets and First Sealing Strip NOTE Windows come in a variety of different styles Therefore it may be necessary to modify or improve your particular installation A Attach the bracket assembly to 90 angle support brackets Fig 5 using 2 1 1 2 bolts Two bolts per bracket Secure with the 2 1 4 lock washers and 2 1 4 nuts DO NOT immediately tighten these bolts as it may be necessary to adjust the depth of the bracket a
7. Cleaning of Air Filter 1 Remove dust clogged in the filter by tapping it or vacuum clean it 2 Wash the filter well with lukewarm water below 40 C 104 F while rubbing lightly To get better results wash it with soapy water or a neutral cleaning agent 3 Rinse the filter well using clean water then dry completely End of Season Care 1 Operate the fan alone for half a day to dry out the inside of the unit 2 Turn off power and remove plug from wall socket 3 Clean filter 4 Store in a dry location WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page ne TROUBLESHOOTING GUIDE Frequently a problem is minor and a service call may not be necessary use this troubleshooting guide for a possible solution PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will not operate No power to the unit Check connection of power cord to power source Check fuse or circuit breaker Set FAN CONTROL to position other than OFF Inefficient or no cooling Dirty air filter Inappropriate capacity for application Blocked air flow Power interruption settings change too quickly or compressor overload tripped Clean or replace air filter Check with dealer to determine proper unit capacity for application Remove obstruction from grill or outdoor louvers Let fan run to restart compressor in approximately 10 minutes algae on wet surfaces Noisy unit
8. Insert new batteries making sure that the and of battery are matched correctly Reattach the cover by sliding it back into position Note Use 2 LRO3 AAA 1 5volt batteries Do not use rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim If the replacement is done within 1 minute the remote control will keep original presetting e How to Use To operate the room air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 23 feet when pointing at signal receptor of indoor unit CCL UCC Remote Control Presetting The remote control is NOT preset as Cooling Signal receptor only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator and Heating indicator will flashes alternately on LCD of the remote control User can preset the remote control type depending on the air conditioner type you have purchased as follows Press any button when flashes Heat Pump will be set Press any button when flashes Cooling Only will be set If you don not press any button within 12 seconds the remote control will be set as Heat Pump automatically Back light function optional Hold down any button of remote control for about 2 seconds back light turns on Release
9. Care and Maintenance ccc cee es 17 Trouble Shooting Guide 1 ee ee 18 Warranty oocccco ee eee eee eee tenes 19 4 INDICE Page INTOUCCI N or cae a ee ee ee ee a ee oe ra 20 Identificaci n de las Piezas 1 kc ee ee 20 21 Especificaciones El ctricas 0 cece eee eee ees 22 Consejos Antes dela Instalaci n 0 000 cece eee eee eens 23 Instrucciones de Instalaci n 0 e ee eee eee eee 24 28 Instrucciones de Operaci n ccc ce ee ee eee 29 32 Cuidado y Mantenimiento 0000 cece eee eee ee ees 33 Gu a para la Soluci n de Problemas 0000 eee u enue eee aenees 34 Gard ooven vas ene wae han hbo E hae Ee ee ee Beene ee eee es 35 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 4 INTRODUCTION Thank you for choosing this room air conditioner to cool your home This USE AND CARE MANUAL provides information necessary for the proper care and maintenance of your new room air conditioner If properly maintained your air conditioner will give you many years of trouble free operation To avoid installation difficulties read instructions completely before starting This manual contains information for the installation and operation of your room air conditioner gt gt Mechanical control model j Control Knob Cabinet Air Outlet Front Panel
10. Para permitir una descarga adecuada de lac ondensaci n ser necesario ajustar la inclinaci n de los soportes en la ventana Para ello ajuste la distancia del tornillo de nivelaci n en la pared exterior La inclinaci n m xima no deber ser superior a3 16 Vea la Fig 7 D Corte la primera sello para que quepa en la parte inferior del marco de la ventana Quite el revestimiento de la tira y p guela al marco Veala Fig 9 A PRECAUCION A Utilice untaco de madera para proporcionar estabilidad Esto ser necesario cuando el umbral de la ventana sobresalga mucho del plano de la pared Vea la Fig 8 VISTA SUPERIOR Ranura eny P o Oo 0 o o O O O o Soporte Ensamblado 90 Pernos del Soporte Soportes en Escuadra Tornillo de gt Nivelaci n Fig 5 Ranura en V Centro Umbral de la Ventana Medida para elModelo 8K 7 5 Medida para elModelo 10K 9 6 Medida para elModelo 12K 10 3 Medida para elModelo 24K 12 6 Fig 6 2 tornillos de 3 4 por soporte aL 20 06 000 00 0 0 4 M ximo de 3 16 Soporte en Escuadra Tornillo de Nivelacin lt q Pared Externa Fig 7 0000000 00 0 0 NASN Taco de Madera si es necesario Fig 8 pl Ny Marco de la Ventana
11. Por lo general el filtro deber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad del aire exterior o interior 3 Puede utilizar tapices cortinas o pantallas para evitar que la luz directa del sol caliente su habitaci n pero NO obstruya el aire acondicionado Permita que el aire circule alrededor de la unidad sin obstrucciones 4 Encienda el aire acondicionado antes de que la temperatura exterior sea demasiado elevada y desagradable De esta manera evitar sufrir calor mientras la unidad enfr a la habitaci n 5 Cuando la temperatura exterior es lo suficientemente fresca utilice s lo HIGH FAN ventilador al m ximo o LOW FAN ventilador al m nimo Esto hace que el aire interior circule a una temperatura agradable y consume menos energ a el ctrica que si hiciera funcionar la unidad como enfriador de aire El Aire Acondicionado para Habitaciones se ha dise ado de modo tal que resulte f cil su instalaci n en ventanas armadas sencillas o dobles NOTA esta unidad NO se ha dise ado para ventanas verticales de tipo deslizante A PRECAUCI N A Para evitar problemas durante la instalaci n o el funcionamiento de la unidad lea completamente las instrucciones NOTA conserve la caja de la unidad y los materiales de empaque para almacenarla o transportarla en el futuro Antes de instalar la unidad compare el contenido del juego de herrajes con la lis
12. U U Algunos estados no permiten la exclusi n o la limitaci n de danos fortuitos o consecuentes Esta garant a le da las derecho espec ficos y usted puede tambi n tener otras erechos que puedan variar de estado a estado Para saber cu les son sus derechas legales consulte asu oficina local del consumidor oa la procuraduria de su estado WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page o WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page 26 WAC 8 24 USER MAN FINAL 3 2 03 12 14 PM Page o Admiral 2005 Admiral Kelon Air Conditioner Co and Kelon USA Inc All rights reserved Printed in China
13. ajustar el modo de energia ahorro O OQ Q O O O O O 9 OO S mbolos indicadores en pantalla Z Transmis nde senal Indicador de enfriado Indicador de ventilador Energia ahorro Velocidad autom tica Je Velocidad lenta F J F Indicador de temperatura te Velocidad mediena dsd pida OO Indicador de temporizador Los simbolos arribas demuestran cuando el modo partinente est usando Despu s de seleccionar un nivel espere 3 minutos antes de pasar a otro Espere 3 minutos antes de recomenzar el aparato WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page o Instrucciones de Operaci n Control remoto e Colocai n de las pilas Retire la tapa de las en el sentido de la flecha Introduzca las pilas nuevas con cuidado de que coincidan los polos y Vuelva a instalar la tapa desliz ndola otra vez a su posici n Nota e Utilice pilas 2 LRO3 AAA 1 5V No utilice pilas recargables Sustituya las pilas por otras nuevas del mismo tipo cuando la pantalla aparezca atenuada e Si la sustituci n se realiza en el plazo de 1 minuto el mando a distancia conservar los valores prefijados oridinales Este funci n es s lo para controlador remoto de LCD e C c mo use ae ne Para operarel aire acondicionado apunte el controlador a remoto la se ar del receptor El controlador remoto sera aoperar el aire acondiciondo con una diata
14. can be killed or seriously inured if you A WAR N i N G don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow these basic precautions e Plug into a grounded 3 prong outlet e Do not use an extension cord e Do not remove ground prong e Unplug air conditioning before servicing e Do not use an adapter e Use two or more people to move and install air conditioner SAVE THESE INSTRUCTIONS WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 7 D INSTALLATION REQUIREMENTS e The air conditioner should be connected to the appropriate electrical receptacle as shown in the chart on Page 6 Receptacle and Fuse Types Power Supply Cord NOTE Your unit s device may differ from the one shown e The use of a time delay fuse or time delay circuit breaker is recommended e All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions contact a qualified electrician A WARNING ELECTRIC a HAZARD Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow thes
15. el cable de alimentaci n del tomacorriente el ctrico 1 NO utilice gasolina bencina disolvente u otros productos qu micos en el aire acondicionado ya que estas sustancias pueden danar el acabado de pintura y deformar las piezas de pl stico 2 Nunca derrame agua directamente en el frente de la unidad ya que danar a el aislamiento el ctrico Limpieza del Filtro de Aire Extracci n del Filtro de Aire Si el filtro de aire se obstruye con polvo el flujo de aire queda obstruido y reduce el rendimiento de la unidad El filtro de aire deber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad de aire exterior o interior C mo Quitar el Filtro de Aire El filtro de aire de los modelos anteriormente mencionados se encuentra detr s de la rejilla de entrada de aire delantera Para quitarlo tome el mango del filtro ubicado enla parte superior de la rejilla de entrada de aire y desl celo hacia arriba Para volver a instalarlo realice los procedimientos anteriores a la inversa A PRECAUCION A NO olvide instalar el filtro de aire Si el aire acondicionado funciona sin el filtro de aire el polvo no se puede eliminar de la habitaci n y es posible que la unidad se descomponga Cuando la rejilla de entrada de aire y el gabinete est n sucios limpielos con agua templada por debajo de los 40 C 104 F Se recomienda el uso de un detergente suave Limpiez
16. est fr a reduzca el nivel a LOW COOL OFF Apagado apaga la unidad completamente Ventilaci n de aire fresco se ra a mantener en la posici n cerrado Usando s lo para limpiar humos y o odores de la habitaci n tire a comenzar Vea la Fig 16 Perilla de Perilla de termostato modo Fig 15 A PRECAUCI N A Cuando utilice la perilla de control de ventilador hagala girar lentamente para permitir que la unidad se adapte al nivel Cuando utilice THERMOSTAT aseg rese de esperar tres minutos antes de cambiar la temperatura Si la cambia demasiado r pido es posible que cause una sobrecarga y se queme el fusible te SS n CCC UCC y Palanca de aire fresco Fig 16 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 Instrucciones de Operaci n Este aire acondicionado se puede operar f cilmente con los botones del panel de control as como tambi n con el control remoto Bot n Encendido Apagado Si presiona este bot n encender el aire acondicionado Cuando el aire acondicionado esta de calefacci n se per imprentar este bot n 3 minutos despu s Bot n Mode Modo Cada vez que se presiona el bot n MODE el modo de operaci n cambia en estas secuencias COOLING Enfriamiento FAN ONLY S lo ventilador ENERGY SAVING Ahorro de Energ a COOLING Enfriamiento NOTA Despu s de se
17. in operation if you press this button Mode BUTTON Used to select the operation mode Each time the Mode button is pressed the operation modeis changed in sequence COOLING FAN ONLY COOLING foo E A Y BUTTONS Used to set room temperature in COOLING mode or used to set time in TIMER mode Temperature setting range is from from 19 C 66 F to 31 C 88 F High BUTTON Used to select the high fan speed mode Mid BUTTON Used to select the Mid fan speed mode Low BUTTON Used to select the Low fan speed mode Auto BUTTON Used to select the Auto fan speed mode Timer BUTTON Used to set or cancel timer operation Saver BUTTON Used to select the Energy saving mode 9 QOO S 0 QOO OOOO OO Indication symbols of LCD on remote control FS Signal transmit sk Cooling A Fan only Energy saving q F Display set temp DO Display set timer Auto fan speed Je Low fan speed efe Medium fan speed k High fan speed The Above symbols are shown when the relevant mode is in use When Changing modes during operation sometimes the unit does not always respond at once Wait 3 minutes Wait 3 minutes before restarting the appliance WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page Be OPERATING INSTRUCTIONS Remote control e How to Insert the Batteries Remove the battery cover according to the arrow direction
18. recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting 2 The air filter is very efficient in removing airborne particles Keep the air filter clean Typically the filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality 3 Use drapes curtains or shades to keep direct sunlight from heating your room but DO NOT obstruct the air conditioner Allow air to circulate around the unit without obstructions 4 Start your air conditioner before outdoor air becomes hot cold and uncomfortable This avoids an initial period of discomfort while the unit is cooling or heating off the room 5 When outdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting Your Room Air Conditioner was designed for easy installation in a single or double hung window NOTE This unit is NOT designed for vertical slider type windows A CAUTION A To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of the hardware kit against the corresponding model check list prior to installation of the unit Se
19. shown in Fig 7 A L Shaped Seal Mounting Channel 7 Secure Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the cabinet See Fig 12 Secure the top of the frames to the window sash with Fig 11 3 4 screws 2 3 4 screws C Now secure bottom frame of shutters using one shutter clamp and one 3 4 screw on each side Fig 12 L Shaped Seal Mounting Channel 8 Reinstalling Front Panel Assembly A Position the front panel on the cabinet starting at the top The front panel lock tabs must be inserted into the retaining slots in the cabinet Repeat this procedure on D Security Screw all sides B Secure the front grille to the cabinet using the Philips Fig 12 screws removed earlier Fig 7 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page He INSTALLATION INSTRUCTIONS 9 Complete the installation A Cut the foam to fit the opening between the top of yy the inside and outside window See Fig 13 ES T dd a A B Some installations may require additional sealing around the window and air conditioner Check for any Ye air leaks and sea
20. Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Remove drain plug and drain base pan Replace drain plug Clean unit thoroughly Water dripping outside Condensation run off is normal during hot and humid weather Add flexible tubing to redirect water flow See Fig 14 Page 12 Water dripping inside Unit is not properly angled to allow water to drain outside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Ice or frost build up Low outside temperature Unit air filter is dirty When outdoor temperature is approximately 65 F or below frost may form when unit is in cooling mode Switch unit to FAN only operation until frost melts Remove and clean filter NOTE If circuit breaker is tripped repeatedly or fuse is blown more than once contact a licensed technician WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 WARRANTY 9 YEARFULL WARRANTY This product is warranted for 5 years from the date of original purchase Any part which fails in materials or workmanship will be replaced within the warranty period This warranty covers in home service Acopy of your proof of purchase with date of purchase and product name included is required to arrange this service repair For the name and location of an authorized service provider near
21. TA Si el cortacircuito interrumpe la corriente varias veces o el fusible se quema m s de una vez comun quese con un t cnico licenciado WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page ep Garantia GARANTIA COMPLETADE 5ANOS Este producto se garantiza por 5 anos a partir de la fecha de la compra original Cualquier parte que falle en materiales o la ejecuci n ser substituida dentro del per odo de la garant a Esta garantia incluye servicio a domicilio Una copia de su prueba dela compra con la fecha de la compra del producto incluida se requiere para acordar esta reparaci n del servicio Para el nombre y la localizaci n de un prestador de servicio autorizado lo m s cerca posible a usted llame porfavor al 1 877 465 3566 Refi rase porfavor al nombre del producto ala marca y al n mero de modelo cuando usted llama Esta garant a nose aplica si el dano ocurre debido a accidente manejo u operaci n incorrectos danos de transporte abuso uso err neo reparacion no autorizada eluso comercial del producto utro uso para el cual no fuera pensado TODAS LAS GARANT AS EXPRESADAS O IMPLICADAS DURAN POR5ANOS A PARTIR DE LA FECHA DE LACOMPRA ORIGINAL ESTA GARANTIA NO CUBRE LARESPONSABILIDAD POR LOS DANOS FORTUITOS O CONSECUENTES PARA CUALESQUIER CAUSA EN NINGUNCASO Esta garant a se extiende al due o original y a cualquier due o subsiquiente para los productos comprados parael uso casero dentro de los E E
22. a del Filtro de Aire 1 Elimine el polvo acumulado en el filtro Para ello apl quele unos golpes suaves o una aspiradora dom stica 2 Lave bien el filtro con agua templada de temperatura inferior a los 40 C 104 F mientras lo frota suavemente Para obtener mejores resultados l velo con agua jabonosa o con un producto de limpieza neutro 3 Enjuague bien el filtro con agua limpia y luego s quelo completamente Cuidado de Fin de Temporada 1 Haga funcionar el ventilador durante medio d a para que se seque el interior de la unidad 2 Ap guelo y desench felo del tomacorriente de pared 3 Limpie el filtro 4 Almac nelo en un lugar seco WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page o Gua para la Soluci n de Problemas Generalmente los problemas son sencillos y es probable que no sea necesario llamar a un t cnico Esta gu a puede ayudarlo aresolverlos PROBLEMA CAUSA POSIBLE SOLUCIN SUGERIDA El aire acondicionado no funciona La unidad no recibe suministro el ctrico Verifique si el cable de alimentaci n e st conectado al tomacorriente Verifique el fusible o el cortacircuito Fije el FAN CONTROL control del ventilador en una posici n que no sea OFF Enfr a poco o nada Filtro de aire sucio Capacidad inadecuada para la aplicaci n Flujo de aire obstruido Corte de energ a el ctrica se cambi de nivel demasiado r pido o se dispar el interrupto
23. apagado de la unidad y luego indicar la temperatura fijada Si presiona el bot n TIMER dentro de esos 12 segundos se desactivar la funci n OFF TIMER Si selecciona ON TIMER la pantalla del temporizador indicar el tiempo restante para el encendido de la unidad Si desea cancelar lafunci n ON TIMER presione el bot n TIMER Bot n A V Se utiliza para fijar la temperatura ambiente en modo COOLING o para programar la hora en modo TIMER Sise presionan las dos teclas a la vez el indicador de temperatura alternar entre C y F NOTA el rango de temperaturas oscila entre 19 C 66 F y 31 C 88 F WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 Instrucciones de Operaci n Control remoto 0 Bot n Encendido Apagado El aparato se encender si est apagado E N o apagar cuando est en operaci n si oprime este bot n a Bot n MODE Modo Utilice este bot n para seleccionar el modo de operaci n E Bot n 4 v Botones de ajuste de temperatura oprima para ajustar la temepratura del cuarto oprima para programar la hora Bot n High Para ajustar el modo alta velocidad de ventilador Bot n Mid Para ajustarel modo mediana velocidad de ventilador Bot n Low Eva Para ajustarel modo baja velocidad de ventilador Bot n Auto i Para ajustar el modo auto velocidad de ventilador Bot n Timer Temporizador Para ponero cancelarla operaci n de timer Bot n Saver Para
24. can result in back or other injury Remove and properly dispose of packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle air conditioner with care WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 8 ELECTRICAL SPECIFICATIONS 1 All wiring must comply with local and national Ly Electric Shock Hazard A electrical codes and must be installed by a licensed electrician If you have any questions If the air conditioner has a serial plate rating regarding the following instructions contact a of 115 volts and up to and including 7 5 amps licensed electrician the unit maybe on a fuse or circuit breaker with other devices However the maximum 2 Check available power supply and resolve any amps on all devices for that fuse or circuit wiring problems BEFORE installing and operating cd sales ital the amps of the fuse this unit 3 For your safety and protection this unit is If the air conditioner has a serial plate rating grounded through the power cord when of 115 volts and greater than 7 5 amps it must have its own fuse or circuit breaker plugged into a matching wall outlet If you a
25. des cooling automatically with middle air circulation Recommended for night quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL OFF will completely shut off the unit NOTE After setting the mode allow 3 minutes before switching to another mode SaaS Te e gt gt 02 gt 2 gt gt gt gt CCC UCC Fresh Air Ventilation is usually kept in the closed position Use only when clearing smoke and or odors from the room Pull to open E 2 gt Fresh Air Vent Lever Fig 16 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page ES OPERATING INSTRUCTIONS gt You can easily operate this air conditioner by pressing relevant button on the control panel as well as the remote control Button The air conditioner will be started when it is energized or will be stopped when it is in operation if you press this button Mode button Each time Mode button is pressed the operation mode is changed in sequence COOLING FAN ONLY ENERGY SAVING COOLING NOTE After setting the mode allow three 3 minutes before switching to another mode In the FAN ONLY Mode Room Temperature display range is from 0 C 82 F to 38 C 99 F Room Temperature below 32 F the Temperature display LO Room Temperature above 99 F the Temperature display H1 Fan Speed button Used to select fa
26. e instructions can result in death fire or electrical shock e The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to rest B Test Button A Reset Button This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button will trip and pop out 4 Press and release RESET listen for click Reset button will latch and remain in The power supply cord is ready for operation NOTES e The Reset button must be pushed in for proper operation e Do not use the power supply cord as as an off on switch The power supply cord is designed as a protective device e A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired e The power supply cord contains no use serviceable parts Opening the tamper resistant case voids all warranty and performance claims INSTALLATION INSTRUCTIONS Remove packaging materials A warnine EXCESSIVE WEIGHT HAZARD Use two or more people to move and install air conditioner Failure to do so
27. e la Fig 11 ventana con 2 tornillos de 3 4 C Ahora asegure el marco inferior de las persianas a con unagrapa yun tornillo de 3 4 de cadalado Fig 12 8 Como Volver alnstalar el Panel Frontal A Coloque el panel frontal enel gabinete comenzando porla parte de arriba Las trabas del panel frontal deben insertarse en las ranuras de sujeci n del gabinete Repita este procedimiento de todoslos lados Canal de Sello Montaje en Forma de L Serpent n J Tornillo deSeguridad B Asegure la rejilla frontal al gabinete con los tornillos Philips que quit anteriormente Fig 1 Fig 12 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page o Instrucciones de Instalaci n 9 Finalice la instalaci n A Corte la espuma para que quepa en la abertura A entre la parte superior del interior y exterior de la Yi Espuma ventana Vea la Fig 13 a B Es probable que algunas instalaciones necesiten Yi tira selladora adicional alrededor de la ventana y el aire acondicionado Verifique si hay alguna p rdida Ya de aire y s llela sies necesario C Enzonas de mucha humedad es posible que la descarga de agua haga que la unidad desborde o que elaire acondicionado haga m s ruido Si esto sucede puede acoplar una manguera de desagiie no incluida al tap n de dr
28. e lists below Fig A Fig A Installation Hardware gt 3 4 Screws 10 Shutter Clamp 2 1 4 2 5 14 Screws 23 O Gasket 10 A Top Channel 1 Side Curtain RH 1 Bottom Channel 1 For 8K to 12K models Side Curtain LH 1 Bottom Channel 1 For 15K to 24K models Factory installed Lock Washers 4 z J Y A xx 1 1 2 x1 4 Bolts 4 Seal 1 1 4 Nuts 4 p A Foam 1 J 0000000 Q00 0 0 Mounting Brackets 2 Double Angle Adhering i Brackets 2 Seal 1 t End Cap amp Leveling Legs 2 NOTE Surplus screw s for spare use Tools Needed for Window Installation Screw drivers Both Philips and flat head Power drill 1 8 inch diameter drill bit Pencil Measuring tape Scissors Carpenters level WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page ne INSTALLATION INSTRUCTIONS A CAUTION A Because the compressor is located on the controls side of the unit right side this side will be heavier and more awkward to manipulate Inadequate support on control side of the unit can result in personal injury and damage to your unit and property Therefore it is recommended to have someone assist you during the installation of this unit 1 Select the Best Location A Your room air conditioner was designed to fit easily into a single or double hung window However since window de
29. eccion WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page O Especificaciones el ctricas 1 Todos los cables deben cumplir con los c digos el ctricos locales y nacionales y los debe instalar un electricista licenciado Si tiene preguntas relacionadas con las siguientes instrucciones comun quese con un electricista licenciado 2 Verifique el suministro de energ a disponible y resuelva cualquier problema con los cables ANTES de instalar y hacer funcionar esta unidad 3 Para su seguridad y protecci n esta unidad est conectada a tierra a trav s del cable de alimentaci n cuando se lo enchufa a un tomacorriente de pared provisto de conexi n a tierra Si no est seguro de que el tomacorriente de pared cuenta con la conexi n a tierra apropiada consulte con un electricista licenciado 4 El tomacorriente de pared de 3 clavijas debe coincidir con el enchufe de 3 clavijas del cable de alimentaci n suministrado con la unidad NO utilice adaptadores de enchufe ni cables de extensi n Consulte la Tabla 1 para obtener informaci n acerca de recept culos y fusibles Ly Peligro de Descarga El ctrica A Si el r tulo del aire acondicionado indica 115 voltios y hasta 7 5 amperios la unidad se puede conectar a un cortacircuito o fusible utilizado por otros dispositivos No obstante la suma de los amperios m ximos de todos los dispositivos conectados a dicho cortacircuito o fusible no deben exceder lo
30. enaje para que las condensaciones se descarguen bien Vea la Fig 14 Manguera de Y Desague no incluida WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page ae Instrucciones de Instalacion MODE Modo La perilla de modo controla las velocidades de ventilador y de enfriamiento Para fijar una temperatura de enfriamiento simplemente haga rotar la perilla y col quela en el nivel deseado Vea la Fig 15 THERMOSTAT Termostato El termostato controla autom ticamente el ciclo de enfriamiento compresor del aire acondicionado para mantener la temperatura del ambiente No obstante el motor del ventilador continuar funcionando una vez finalizado el funcionamiento del compresor ciclo de enfriamiento Vea la Fig 15 LOW FAN Ventilador al M nimo har que el aire circule a una velocidad m nima sin enfriar MED FAN Ventilador al Mediano har que el aire circule a una velocidad mediana sin enfriar HIGH FAN Ventilador al M ximo har que el aire circule a una velocidad m xima sin enfriar LOW COOL Fr o M nimo enfr a el ambiente autom ticamente con una circulaci n minima de aire Se recomienda durante la noche MED COOL Fr o Mediano enfr a el ambiente autom ticamente con una circulaci n mediana de aire Se recomienda durante la noche HIGH COOL Fr o M ximo enfr a el ambiente autom ticamente de manera r pida o durante d as de calor intenso Una vez que la habitaci n
31. est you please CALL 1 877 465 3566 Please reference product name brand name and model number when you call This warranty does not apply if the damage occurs because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted or the use of the product for commercial use or any other use for which it was not intended ALL WARRANTIES EXPRESSED OR IMPLIED LAST FOR 5 YEARS FROM THE DATE OF ORIGINAL PURCHASE THIS WARRANTY DOES NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER This warranty is extended to the original owner and any succeeding owner for products purchased for home use within the USA Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific rights and you may also have other rights which may vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 Introducci n Gracias por elegir este aire acondicionado para enfriar su hogar Este MANUAL DE USO Y MANTENIMIENTO proporciona la informaci n necesaria para cuidar y mantener en forma adecuada su nuevo aire acondicionado Funcionar sin problemas durante muchos a os si le brinda el mantenimiento apropiado Para evitar problemas al instalarlo lea completamente las
32. instrucciones antes de comenzar Este manual contiene informaci n acerca de la instalaci n y el funcionamiento del aire acondicionado para habitaciones gt gt Modelo Mec nico Entradade Tirador Controlado Aire Interior Panel Frontal Gabinete Aire Interior eat gt Filtro de Aire en elinterior 2 e Qo o Z So ee a o ay Rejilla de Entrada d a a as n E sd Entrada de Palanca de Aire Fresco Aire Exterior Cable de Alimentaci n Nota Las im genes de este manual est n basadas en la vista externa de un modelo est ndar En consecuencia es probable que laforma sea diferente a la del aire acondicionado que usted seleccion WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 2 Introduccion gt Identificaci n de las Piezas Model
33. ion Ground Fig B 8K 10K Size Model 12K 15 24K Cabinet size VW H D 20 5 14 8 23 1 22 8 15 7 24 1 20 0 18 30 26 9 Min Window 24 opening 27 30 Max Window i 38 opening 41 44 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 29 INSTALLATION INSTRUCTIONS 2 Preparation to Remove the Air Conditioner Slide Out Chassis es A Remove total of 4 Philips screws securing the chassis to the cabinet There are 2 screws on each side The set of screws closest to the front of the unit secure the front panel to the cabinet The set of screw closest to the rear of ai cic the unit secure the cabinet to the chassis Philips screws See Fig 7 i ig y CLCC CCC a Fig 1 B Remove the front panel assembly from the cabinet by gently pulling it Coil C Grasp the pull handle at the front of the slide out chassis and carefully slide the air conditioner out of the cabinet See Fig 2 i Please seek assistance for this procedure i j Chassis Note Screws must be reinstalled upon hen completion of the window installation to CELE Ud secure slide out chassis
34. je suficiente espacio alrededor del gabinete para permitir una amplia circulaci n de aire a trav s de la Cerca unidad Vea Fig 2 La parte posterior de la unidad 5 30 Min a y deber dar al aire libre y no a un garaje ni al interior de ana ET un edificio Mantenga la unidad lo m s lejos posible de obst culos que puedan causar obstrucciones y por lo A menos a 30 del nivel del piso o del suelo Deber n Suelo tomarse precauciones para evitar que las cortinas o cualquier otro objeto dentro de una habitaci n Fig 2 obstruyan el flujo de aire Requisitos para las aberturas de ventanas consulte la siguiente tabla Tama o Modelo gk 10K 12K 15 24K Tama o del gabinete 29 5 44 8 23 1 22 8 15 7 24 1 26 5 18 5 26 9 Abertura minima 24 27 30 de Ventana Abertura maxima 38 41 AA de Ventana WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 19 Instrucciones de Instalaci n 2 C mo quitar el armaz n deslizable del aire acondicionado A Quite los 4 tornillos Philips que sujetan el armaz n al gabinete Hay 2 tornillos de cada lado Los tornillo s que est n m s cerca del frente de la unidad sujetan el panel frontal al gabinete Los tornillos que est n m s cerca de la parte trasera de la unidad sujetan el gabinete al armaz n Vea la Fig 1 B Quite el panelfrontal del gabinete tirando suavemente de l C Tome el mango que est en el frente del a
35. l where necessary Fig 13 C In very humid areas the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations to run off conveniently See Fig 14 WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page e OPERATING INSTRUCTIONS gt MODE The mode knob controls fan speeds and cooling speeds To set desired cooling temperature simply rotate the mode knob dial to the appropriate setting THERMOSTAT The thermostat automatically controls the cooling cycle compressor of the air conditioner to maintain room temperature However the fan motor will continue to operate after the compressor cooling cycle is completed LOW FAN will circulate the air at a minimum speed without cooling MED FAN will circulate the air at a middle speed ao A without cooling HIGH FAN will circulate the air at a maximum speed Fig 15 without cooling LOW COOL provides cooling automatically with minimum air circulation Recommended for night A CAUTION A time use When using FAN control turn slowly allowing unit to adjust When using THERMOSTAT be sure to allow ti three minutes before changing temperature Ime use ae Adjusting too quickly may cause an overload HIGH COOL provides cooling automatically with resulting in a blown fuse MED COOL provi
36. leccionar un nivel espere 3 minutos antes de pasara otro Con el modo de FAN ONLY El recinto de la temperatura Dehabitaci n ser Desde 0 C 32F hasta 38 C 99 F La temperatura de la habitaci n es superior a32 F la temperatura lucer LO La temperatura de la habitaci n es superior a 99 F la temperatura lucer H1 Bot n Fan Speed Velocidad del Ventilador Se utiliza para seleccionar la velocidad del ventilador en secuencia autom tica baja media y alta Bot n Timer Temporizador Se utiliza para programaro cancelar el funcionamiento del temporizador Cuando la unidad est en funcionamiento puede seleccionar OFF TIMER Apagar Temporizador Cuando la unidad est apagada puede seleccionar ON TIMER Encender Temporizador El rango de horas para programar el temporizador es de 0 a24 horas Panel de Control Airconditioner S mbolos del indicador del panel del control Ventilador en velocidad autom tica W Ventilador en velocidad baja E Ventilador en velocidad media Ventilador en velocidad alta gt lt Enfriamiento A S lo ventilador O Temporizador E Ahorro de energ a 0 Calefacci n F Mostrar temperatura fijada HR Mostrar hora programada Las luces del indicador LED anteriormente mencionadas se encienden cuando se usan los modos correspondientes Si selecciona OFF TIMER la pantalla del temporizador indicar durante 12 se gundos el tiempo restante para el
37. n speed in sequence auto low medium and high Timer button Used to set or cancel timer operation Control Panel Indication symbols of LED on control panel A Auto fan speed A Low fan speed ef Medium fan speed High fan speed LED on control panel lights on when the relevant mode is in used SJL i gt lt Cooling 1 im F et ti A Fan only cos E i Display set temp O Timer Display set timer i E Energy saving 6 Heating When the unit is in operation you can set OFF TIMER When the unit is off you can set ON TIMER Timer setting range is 0 to 24 hours If the OFF TIMER is set the time LED displays the remaining time to turn off the unit for only 12 seconds then LED shifts to display set temperature If you press TIMER button within the 12 seconds OFF TIMER will be cancelled If the ON TIMER is set the timer LED displays the remaining time to turn on the unit If you want to cancel ON TIMER press TIMER button A V Button Used to set room temperature in COOLING mode or used to set time in TIMER mode If the two keys are pressed at the same time the temperature LED display will alternate between C and F NOTE Temperature setting range is from 19 C 66 F to 31 C 88 F WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page o OPERATING INSTRUCTIONS Remote control BUTTON The appliance will be started when it is energized nn N or will be stopped when it is
38. ncia hasta 23 pies cuando apunta a la se ar del receptor de la unidad CCC UCC e Preparaci n antes de usar Antes de usar el aire acondicionado Receptor de senal aseg rese a comprobar y controlar el siguiente El ajusmiento del controlador remoto El controlador remoto no se ajusta como aire acondicionado con frio solo o con calefacci n Cada vez despu s de que el controlador remoto se cambia las bater as o es energiado el indicator de Cooling y elindicator de Heatingg se van alanzar alternativament en LCD delcontrolador remoto Usador puede ajustar el tipo del controlador remoto seg n eltipo de aire acondicionado que compraste Precione cualquier bot n cuando lanza calefacci n se establece Precione cualquier bot n cuando lanze frio se establece Si no preciones cualquier bot n sin 12 seguandos el controlador remoto ajusta como calefacci m automaticamente e Funci nde lar para espalda opcional Mentenga cualquier bot n del controlador remodo con 2segundes lal mpara espalda encende Espere 3 minutos antes de recomenzar el aparato Escapa el bot n lal mpara apaga 10 segundos despu s autom ticamente WAC 8 24 USER MAN FINAL 3 2 05 12 14 PM Page 26 Cuidado y Mantenimiento Cuando repare el aire acondicionado aseg rese de colocar la perilla de modo en OFF y luego desconectar
39. o de Remoto controlador Panel Frontal Filtro de Aire Rejilla de Entrada de Aire Interior Nota Gabinete Entrada de Aire Interior Panel de Control O tee ro Jer A ORIO RNG LARRI RORA OK RXR PRI RR RR TR PORRA RRA o il PRI RR RS J RR RRA KKK AZ O III OLI II PIZZERIA ol PR RR LIN RIAU RR II RRR DRSNA 1999 XX LS O PRI x F E x BERRY OZ N LS POIS II PIS MM RRR PSH LI IR PTI LA POR RR PRI Ye y LAS X o RRR A ZA DKK RY Palanca de Aire Fresco Panel de Control Air conditioner CC Lo Entrada de Aire Exterior Cable de Alimentaci n Control Remoto A ES Las im genes de este manual est n basadas en la vista externa de un modelo est ndar En consecuencia es probable que la forma sea diferente ala del aire acondicionado que usted sel
40. r por sobrecarga del compresor Limpie o reemplace el filtro de aire Hable con el representante para determinar cu l es la capacidad adecuada para la aplicaci n Quite toda obstrucci n de la rejilla o de las persianas exteriores Haga funcionar el ventilador para reiniciar el compresor en aproximadamente 10 minutos Unidad ruidosa Piezas sueltas Soporte inadecuado Ajuste las piezas sueltas Proporcione soporte adicional a la unidad Olores Formaci n de moho u hongos sobre las superficies h medas Quite el tap n de drenaje y la bandeja base Cambie el tap n de drenaje Limpie la unidad en forma completa Gotea agua afuera Es normal la descarga de condensaci n cuando el clima es c lido y h medo Utilice tuber as flexibles para desviar el flujo de agua Gotea agua adentro La unidad no est bien inclina da como para permitir el desagiie externo La unidad debe instalarse con un ligero desnivel para permitir una descarga adecuada de la condensaci n Verifique la unidad y realice los ajustes necesarios Se forma hielo o Baja temperatura exterior Cuando la temperatura exterior sea inferior a los 65 F es posible que se forme escarcha si escarcha la unidad funciona en modo de enfriamiento Cambie el funcionamiento de la unidad a FAN solamente hasta que la escarcha se derrita El filtro de aire de la unidad Quite el filtro y l mpielo est sucio NO
41. re and ne otierdevics or unit should be not sure whether your wall outlet is properly operated on the fuse or circuit breaker grounded please consult a licensed electrician If the air conditioner has a serial plate rating 4 The wall outlet 3 pin must match the plug of 230 volts it must have its own fuse or 3 pin on the power cord supplied with the unit Era be eee or a DO NOT use plug adapters or extension cords breaker See Table 1 for receptacle and fuse information 5 The rating plate on the unit contains electrical To avoid the possibility of personal injury and other technical data The rating plate is disconnect power to the unit before installing located on the front of the base pan Make sure or servicing to use the correct power supply according to the rating plate of your air conditioner RECEPTACLE AND FUSE TYPES COOLING CAPACITY 8K 15K 18K 22K 24K RATED VOLTS 125 250 250 AMPS 45 45 m WALL OUTLET ae FUSE SIZE 15 15 20 Note 8K 15K including AAW 08CM1FHUE AAW 08CR1FHUE Table 1 AAW 10CM1FHUE AAW 10CR1FHUE AAW 12CM1FHUE AAW 12CR1FHUE AAW 15CM1FHUE AAW 15CR1FHUE 18K including AAW 18CR3FHUE AAW 18CM3FHUE 22K 24K including AAW 22CR3FHUE AAW 22CM3FHUE AAW 24CR3FHUE AAW 24CM3FHUE WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 9 TIPS BEFORE INSTALLATION Your Room Air Conditioner unit is designed to be highly efficient and save energy Follow these
42. rmaz n deslizable y saque con cuidado el aire acondicionado del gabinete Vea la Fig 2 Nota una vez finalizada la instalaci n en la ventana debe volver acolocar los tornillos para sujetar el armaz n deslizable Pida ayuda para realizar este procedimiento 3 Montaje de los canales superiore inferior en el gabinete A Canal Superior en Forma de L Aguante el doble sello adhesiva al canal superior en forma de L con 5tornillos de 1 4 instale el canal superior en forma de L sobre el gabinete tal como seindica enla Fig 3 B Instale el Canal Inferior en forma de U tal como seindica enla Fig 3 Nota Para los modelos de 15Ka 24K el canal de bot n se ha instalado en la f brica y su forma ser distinto a otros pero susfucciones son semejantes 4 Montaje de las persianas laterales cortinas en el gabinete Deslice las persianas porlos canales superior e inferior tal como se indica en la Fig 4 En cada marco las persianas se identifican como izquierda y derecha Sujete las persianas al gabinete con 4 tornillos de 1 4 de cadalado Tee CLUE UCC Lado derecho Tornillos Philips Fig 1 Serpentin a a Doble Sello Adhesiva Para modelos de 8K a 12kK Para modelos de 15K to 24K instalado en la f brica Fig 3 Marco de la Per
43. s amperios del mismo Si el r tulo del aire acondicionado indica 115 voltios y m s de 7 5 amperios debe tener su propio fusible o cortacircuito y no se deber conectar ning n otro dispositivo o unidad a dicho fusible o cortacircuito Para evitar lesiones f sicas desconecte el suministro de energ a de la unidad antes de instalarla o repararla 5 El r tulo de la unidad contiene datos el ctricos y t cnicos Dicho r tulo se encuentra en el lado derecho de la unidad Tipos de Recept culos y Fusibles Note 8K 15K Incluido AAW 08CM1FHUE AAW 08CR1FHUE MODEL 8K 15K 18K 22K 24K CAPACIDAD DE VOLTIOS 123 250 250 AMPERIOS 15 45 a AMPERIOS ae TAMANO D EL FUSIBLE 15 15 20 Tabla 1 AAW 10CM1FHUE AAW 10CR1FHUE AAW 12CM1FHUE AAW 12CR1FHUE AAW 15CM1FHUE AAW 15CR1FHUE 18K Incluido AAW 18CR3FHUE AAW 18CM3FHUE 22K 24K Incluido AAW 22CR3FHUE AAW 22CM3FHUE AAW 24CR3FHUE AAW 24CM3FHUE WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page s Consejos antes de la instalaci n Su unidad de Aire Acondicionado para Habitaciones se ha disenado para lograr un alto rendimiento y ahorrar energ a el ctrica Siga las siguientes sugerencias para lograr un mayor rendimiento 1 Ajuste el termostato a un nivel que le resulte agradable y d jelo en el nivel seleccionado 2 El filtro es muy eficiente a la hora de eliminar part culas que se desplazan por el aire Mantenga limpio el filtro de aire
44. sado y m s dif cil de manipular los cables deber n cumplir con los c digos el ctricos Si la unidad no se sostiene bien de dicho lado locales y nacionales pueden producirse lesiones f sicas y da os a la unidad y a su propiedad Por lo tanto le recomendamos que para instalar esta unidad e F La unidad est dise ada para evaporar la condensaci n solicite ayuda a otras personas bajo condiciones normales No obstante bajo condiciones de extrema humedad es probable que la condensaci n na dni excesiva haga que la bandeja base se desborde hacia el A El aire acondicionado para habitaciones tiene un i a exterior Por lo tanto la unidad deber instalarse en un lugar dise o que facilita su colocaci n en ventanas donde la descarga de la condensaci n no gotee sobre el armadas sencillas o dobles No obstante debido a paso de peatones ni en las propiedades vecinas que los disenos de ventana son tan variados es probable que sea necesario realizar algunas modificaciones para lograr una instalaci n segura y adecuada 1 Seleccione la Mejor Ubicaci n B Aseg rese de que la ventana y el marco tengan una estructura firme y que la madera no est rajada ni podrida C Para lograr el m ximo rendimiento instale el aire acondicionado del lado de la casa o edificio donde haya m s sombra que sol Si la unidad se encontrara expuesta a la luz del sol es aconsejable colocarle un toldo encima D De
45. siana WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page 26 Instrucciones de Instalacion 5 Instalaci n de los Soportes Horizontales y de la Primera Tira Adhesiva Selladora NOTA Existe una gran variedad de estilos de v entanas Porlo tanto es probable que se a necesario modificar o mejorar su propia instalaci n A Sujete el soporte horizontal alos soportes en escuadra Fig 5 con 2 pernos de 1 1 2 Hay dos pernos por soporte Aseg relos con las 2 arandelas de presi n de 1 4 y las 2 tuercas de 1 4 NO ajuste estos pernos de inmediato ya que es posible que sea necesario ajustar la distancia del soporte ensamblado dependiendo de la profun didad del umbral de la ventana Veala Fig 7 Instale los dos tornillos de nivelaci n enlos sop ortes en escuadra A modo de prueba coloque el soporte ensamblado en la ventana antes de instalar el gabinete Silos tornillos de nivelaci n estan demasiado lejos de la pared como para proporcionar estabilidad es probable que sea necesario complementar dicha rea con un taco de madera Vea la Fig 8 B Mida el ancho del interior del umbral de la ventana y defina el centro tal como se indica en la Fig 6 Alinee la ranura en V de cada soporte ensamblado sobre estas marcas y monte los soportes al umbral con los tornillos de 3 4 proporcionados Los soportes deber n quedar perpendiculares al umbral interno de la ventana Veala Fig 6 C
46. signs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and frame is structurally sound and free from dry and rotted wood C For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight itis advisable to provide an awning over the unit D Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit See Fig B The rear of the unit should be outdoors and not in a garage nor inside of a building Keep unit as far away as possible from obstacles and obstructions and at least 30 above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow Window opening requirements see table below E Be certain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at proper current see table 1 on page 4 All wiring should be in accordance with local and national electrical codes F Your unit was designed to evaporate condensation under normal conditions However under extreme humidity conditions excess condensation may cause the basepan to overflow to the outside The unit should be installed where condensation run off cannot drip on pedestrians or neighboring properties Fence wall or other obstacle Side obstruct
47. ssembly depending on the depth of your window sill See Fig 7 Install the two leveling screws into the 90 support brackets Test the bracket assembly in the window before cabinet installation If the leveling screws are distanced too far away from the wall to provide stability it may be necessary for you to fill this area with a solid piece of wood See Fig 8 B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each bracket on these marks and mount the brackets to the sill using 3 4 screws provided Brackets should be perpendicular to the inside window sill See Fig 6 C For proper condensation run off it will be necessary to adjust the angle pitch of the window brackets This is accomplished by adjusting the distance of the leveling screw on the outer wall The maximum angle pitch should not exceed more than 3 16 See Fig 7 D Cut the seal strip to fit the underside of the bottom window sash Remove the peel off backing on the seal and attach it to this sash See Fig 9 A CAUTION A Use a solid piece of wood to provide stability This will be required when sills are extra deep See Fig 8 TOP VIEW v l loo o o o e e 6 O ae o 0000090000 0 Bracket Assembly 90 Angle Bracket Bolts Support Brackets Leveling Screw gt Fig 5 iia Center
48. ta de control del modelo correspondiente Consulte las siguientes listas Fig 1 Herrajes de Instalaci n Tornillos de 3 4 10 Grapa de Persiana 2 Tornillos de 1 4 23 AL Canal Superior 1 Junta de Culata 10 Canal Inferior 1 8K 12K Cortina Lateral Derecha 1 Cortina Lateral Izquierda 1 Il I Sello 1 Doble Sello Adhesiva 1 S Espuma 1 Fig 1 Nota Tornillo Excedente Para d Uso de Reserva g Y 4 Canal Inferior 1 15K 24K instalado en laf brica Q Arandelas de Presi n 4 Pernos de1 1 2 x1 4 4 Tuercas de1 4 4 o oO o O O 0 O 0 0 oo0oQ0Qo0ooo0oo0oQoooo Soportes Horizontales 2 Soportes en Escuadra 2 pus TapaTrasera y Patas de Nivelaci n 2 Herramientas Necesarias para la Instalaci n en Ventana Destornilladores Philips y de cabeza plana Taladro el ctrico broca de 1 8 pulgada de di metro L piz Cinta m trica Tijeras Nivel de carpintero WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page s Instrucciones de Instalaci n A PRECAUCION A E Aseg rese de instalar la unidad cerca de un tomacorriente el ctrico adecuado Utilice un estime Debido a que el compresor se encuentra del lado al corriente propio lea tabla 1 en p gina 20 con de los controles a la derecha de la unidad este circuito exclusivo para el aire acondicionado Todos lado ser m s pe
49. the button it lights off automatically 10 seconds later WAC 8 24 USER MAN FINAL 3 2 05 12 13 PM Page CARE AND MAINTENANCE When servicing the air conditioner be sure to turn the mode switch to the OFF position and disconnect the power cord from the electrical outlet 1 DO NOT use gasoline benzine thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts 2 Never attempt to pour water directly in front of the unit as this will cause deterioration of the electrical insulation Cleaning the Air Filter Removal of Air Filter If the air filter becomes clogged with dust air flow is obstructed and reduces efficiency The air filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality Air Filter Removal The air filter on the above model is located behind the air intake front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure dh CAUTION A DO NOT forget to install the air filter If the air conditioner is left to operate without the air filter dust is not removed from the room and may cause your air conditioner to fail When the air filter inlet grille and cabinet are dirty wipe with lukewarm water below 40 C 104 F Use of mild detergent is recommended