1. oE 00000000000000000000000 00000000000000000000000 H0549 A BNC connector J3 BNC connector J1 Figure 9 Using BNC Connector Table 4 BNC Connector 71 and J3 Shield LAN CDS Center LAN Connect to a Computer Terminal or Modem The AUX and OS connectors Figure 10 are DB 25 configured as Data Terminal Equipment DTE There is one AUX and one OS connector for each of the two management unit slots Use these connectors for a direct connection straight through with devices configured Data Communication Equipment DCE such as modems 25 Packet Assembler Disassemblers PADs or LAN terminal servers AUX port DB 25 OS port DB 25 AUX port DB 25 OS port DB 25 connector P5 connector P4 connector P3 connector P2 K 9299999999999 o er 222022222222 000000000000 000000000000 er Sk 00000000000000000000000 00000000000000000000000 550 Figure 10 AUX OS Connectors HRM 238 List 1 July 21 2004 Installation LTPH UM 1237 04 Use a null modem connector for cross over cabling when attaching a device that is not configured as DCE such as terminals or computers running terminal emulation software to these connectors Table 5 shows the pinouts for the two AUX ports one port for each management uni
2. 2 Loosen the security bracket screw push down the security bracket and re tighten the screw Figure 6 on page 5 12 July 21 2004 HRM 238 List 1 1237 04 Appendix Specifications APPENDIX SPECIFICATIONS Power Maximum power CO Supply Fuse Size Physical Material Finish Capacity Mounting Dimensions Height Width Depth including the wire wrap terminals Weight Operational Environment Temperature Humidity Altitude Storage Environment Temperature Humidity HRM 238 List 1 10 0 Watts 48 nominal 42 5 to 56 5 0 5A Steel Zinc plated 2 management modules HMU 319 or MMU 319 19 or 23 inch rack 1 75 in 4 39 cm 17 in 43 18 cm without mounting brackets 18 37 in 46 65 cm mounting brackets set for 19 inch rack 22 37 in 56 82 cm mounting brackets set for 23 inch rack 12 in 30 48 cm 2 5 Ib 1 13 kg 40 C to 65 C 5 to 95 non condensing 200 ft below sea level to 13 000 ft above sea level 60m below sea level to 4 000m above sea level 40 C to 70 C 5 to 95 non condensing July 21 2004 13 Appendix Product Support APPENDIX PRODUCT SUPPORT 14 LTPH UM 1237 04 ADC Customer Service Group provides expert pre sales and post sales support and training for all its products Technical support is available 24 hours a day 7 days a week by contacting the ADC Technical Assistance Center Sales Assistanc
3. Appendix C Abbreviations on page 15 INSPECTING SHIPMENT Upon receipt of the equipment Unpack each container and inspect the contents for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and to ADC Telecommunications Inc Order replacement equipment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact ADC as described in Appendix B Product Support on page 14 If you must store the equipment for a prolonged period store the equipment in its original container HRM 238 List 1 July 21 2004 Inspecting Shipment LTPH UM 1237 04 iv July 21 2004 HRM 238 List 1 1237 04 5 Overview Table of Contents Features Operational Capabilities Installation Management Cabling Inspecting Your Shipment Installing the HRM 238 Shelf Installing Frame Ground and Battery Power Installing Communication Wiring Connect NMA Wiring Identifying Alarms Turning Up the System Installing the Management Unit s Appendix A Specifications Appendix B Product Support Appendix Abbreviations Certification and Warranty HRM 238 List 1 Verify Cabling Secure Cabling Connect to aLAN or Interconnect Shelves Connect to a Computer Terminal or Modem 15 July 21 2004
4. HRM 238 List 1 HiGain Retrofit Management Shelf User Manual Product Catalog HRM 238 11 CLEI TIMFWOO4 LTPH UM 1237 04 Revision History To order copies of this manual use document catalog number LTPH UM 1237 04 Copies of this publication can be downloaded from the ADC website at www adc com To order a hard copy please contact your sales representative Issue Release Date Revisions Made 1 May 9 2003 Initial release 2 March 31 2004 Updated Certificate and Warranty and Product Support Sections 3 April 28 2004 Misc technical updates 4 July 21 2004 Misc technical updates additions Copyright July 21 2004 2004 ADC Telecommunications Inc All rights reserved Trademark Information ADC and HiGain are registered trademarks of ADC Telecommunications Inc No right license or interest to such trademarks is granted hereunder and you agree that no such right license or interest shall be asserted by you with respect to such trademark Other product names mentioned in this document are used for identification purposes only and may be trademarks or registered trademarks of their respective companies Disclaimer of Liability Information contained in this document is company private to ADC Telecommunications and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of ADC Contents herein are current as of the date of publication ADC reserves the right
5. BNC for connection to a Local Area Network LAN or to aHMU 319 multi shelf connection screw type terminals for 48 Vdc power connection and grounding 23 wire wrap pins to monitor alarm relay activity 238 List 1 July 21 2004 1 Overview LTPH UM 1237 04 OPERATIONAL CAPABILITIES Application With two HMU 319 management units installed the HRM 238 shelf provides network management for up to 56 HiGain line units Recommended Network Setup for 220 Type Shelves The configuration shown in Figure 2 is the recommended setup for 220 type mechanics shelves Position the 238 shelf between the 220 type shelves with up to two 220 type shelves above and two below This limits the distance for the wire leads between the connectors for the management units and the line units they manage Figure 2 shows the HRM 238 shelf from the rear view with the A side connectors on the right and the B side connectors on the left The leads from the HRM 238 shelf connector attach to the Network Management Agent NMA pins on the rear of the 220 type mechanics shelves for each line unit managed The NMA pin on 220 type chassis is pin 46 NMA 1 to 14B HCS 417 418 NMA 15 to 28 HCS 417 418 CO 48V So T TB1 NMA 1 to 28 B Network B HRM 238 Network A NMA 1 to 28A HCS 417 418 1 to 14 A 48V A 48V B HCS 417 418 NMA 15 to 28A H0544 B Figure 2 Recommended Network Setup for 220 Type Shelves 2 July 21
6. There is one AUX port and one OS port connector for each management unit TB1 Provides separate 48 Vdc connection from the CO battery source Terminal N A 6 to each management unit Also provides battery common ground and block a frame ground J13 J14 Provides connection for alarm relay contacts Wire wrap Male 23 pins J1 J3 Provides a 10BASE 2 connection to a LAN BNC Female 1 4 July 21 2004 HRM 238 List 1 1237 04 Installation INSTALLATION INSPECTING YOUR SHIPMENT Upon receipt of the equipment Unpack each container and inspect the contents for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and to ADC Telecommunications Inc Order replacement equipment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact ADC as described in Appendix B Product Support on page 14 If you must store the equipment for a prolonged period store the equipment in its original container INSTALLING THE HRM 238 SHELF Install the HRM 238 in a CO equipment bay rack If the CO rack is 19 inches wide attach the short side of the mounting bracket to the HRM 238 shelf and use the long side of the mounting bracket to attach to the CO rack Ifthe CO rack is 23 inches wide reverse the mounting bracket Attach the long side of the mounting bracket to the HR
7. pin 104 on the shelf for each line unit being managed The wire leads from the Amphenol plug can be up to 20 feet maximum 238 List 1 July 21 2004 7 Installation Pin 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Table 3 and P6 NMA Connectors Description NMA_1 NMA_3 NMA_5 NMA_7 NMA_9 NMA_11 NMA_13 NMA_15 NMA_17 NMA_19 NMA_21 NMA_23 NMA_25 NMA_27 F_ALAM LOS_ALM GND GND GND GND GND GND GND N C N C NI pol I July 21 2004 Description NMA_2 NMA_4 NMA_6 NMA_8 NMA_10 NMA_12 NMA_14 NMA_16 NMA_18 _20 _22 _24 _26 _28 ERR_ALM GND GND GND GND GND GND GND GND N C N C LTPH UM 1237 04 HRM 238 List 1 1237 04 Installation Connect to a LAN or Interconnect Shelves Use the BNC connector Figure 9 when required for access using a LAN or for interconnecting multiple shelves Consult the appropriate user manual for the HMU 319 management unit and for the software used in the application See Table 4 for information on BNC connector J1 and J3 u 579 lt 95999999999 o 579 000000000000 000000000000 779
8. 10 change the contents without prior notice In no event shall ADC be liable for any damages resulting from loss of data loss of use or loss of profits and ADC further disclaims any and all liability for indirect incidental special consequential or other similar damages This disclaimer of liability applies to all products publications and services during and after the warranty period July 21 2004 HRM 238 List 1 1237 04 Using This Manual USING THIS MANUAL The following conventions are used in this manual where applicable Monospace type indicates screen text Keys you press are indicated by small icons such as or ENTER Key combinations to be pressed simultaneously are indicated with a plus sign as follows ESC tems you select are in bold The following types of messages identified by icons may appear in text Notes provide information about special circumstances General cautions indicate the possibility of personal injury product failure or equipment N damage if instructions are ignored or not completely followed An Electrostatic Discharge ESD caution indicates that a device or assembly is susceptible to damage from electrostatic discharge An electrical shock warning indicates the presence of dangerous level of electrical power and the potential for serious personal injury or equipment damage For a list of abbreviations used in this document refer to
9. 2004 HRM 238 List 1 1237 04 Overview Recommended Network Setup for 3190 Type Shelves The configuration shown in Figure 3 is the recommended setup for 3190 type mechanics shelves Position the HRM 238 shelf below the 3190 type shelves This limits the distance for the wire leads between the connectors for the management units and the line units they manage Figure 3 shows the HRM 238 shelf from the rear view with the A side connectors on the right and the B side connectors on the left The leads from the HRM 238 shelf connector attach to the Network Management Agent NMA pins on the rear of the 3190 type mechanics shelves for each line unit managed The pin on 3190 type chassis is pin 7 NMA 1 to 28 11028 48V TB1 im NMA 1 to 28 NMA 1 to 28A H0544 C Figure 3 Recommended Network Setup for 3190 Type Shelves Recommended Network Setup for DDM Type Shelves The configuration shown in Figure 4 is the recommended setup for DDM type mechanics shelves Position the HRM 238 shelf below the DDM type shelves This limits the distance for the wire leads between the connectors for the management units and the line units they manage Figure 4 shows the HRM 238 shelf from the rear view with the A side connectors on the right and the B side connectors on the left The leads from the HRM 238 shelf connector attach to the Network Management Agent NMA pins on the rear of the D
10. DM type mechanics shelves for each line unit managed The NMA pin on DDM type chassis is pin 104 NMA 1 to 28A NMA 1 to 28 B TB1 el NMA 1 to 28 B NMA 1 to 28A H0544 D Figure 4 Recommended Network Setup for DDM Type Shelves 238 List 1 July 21 2004 3 Overview LTPH UM 1237 04 Management Cabling Figure 5 shows the location for each connector on the HRM 238 shelf backplane Table 1 lists the shelf connector types and management functions available to the HMU 319 management units through those connectors B side connectors A side connectors 50 pin Amphenol AUX port DB 25 OS port DB 25 AUX port DB 25 OS port DB 25 50 pin Amphenol connector P6 connector P5 connector P4 connector P3 connector P2 connector P1 TED 00000000000000000000000 nn x a 00000000000000000000000 5 H0545 A Alarm relay pins J14 BNC connector J3 Terminal block TB1 Alarm relay pins J13 BNC connector J1 Figure5 HRM 238 Shelf Backplane Connectors back view Table 1 HRM 238 Connectors Connector Purpose Type Gender u P1 P6 Provides connection from the HRM 238 shelf for the management Amphenol Male 50 units to each individual card that they manage CHAMP P2 P3 P5 Provides 4 connection points two for each management unit for a DB 25 Female 25 terminal computer or modem
11. Inside Back Cover List of Figures LTPH UM 1237 04 LIST OF FIGURES 1 HRM 238 List 1 front View Shed he At 1 2 Recommended Network Setup for 220 Type Shelves 2 3 Recommended Network Setup for 3190 Type Shelves 3 4 Recommended Network Setup for DDM Type Shelves 3 5 HRM 238 Shelf Backplane Connectors back view 4 6 Shelf with Brackets Positioned for 19 inch 5 7 Connect 48 and Frame Grounds to 6 8 Connect WirIhg y ee AE RS SA ee ee epe 7 9 BNC 9 10 AUX or OS CODeCIOTS unseren miss 9 11 Alarm Relay Wire Wrap Pins echec pim eerte rete HERO pa ere 11 vi July 21 2004 HRM 238 List 1 1237 04 List Tables LIST OF TABLES 1 239 Connectors bette ha Bacon 4 2 Terminal Block TB uo e ra ur b E UR ete e ER eret e ees 6 3 PO NMA Connectors ete 8 4 BNC Connector J3 kel a eh nee 9 0 and P5 Connectors niae on ce IERI 10 6 05 Port P2 and un u Tere rar e isn ea ead 10 7 Alarm 113 and 314 Pinouts eoe pt
12. M 238 shelf and use the short side of the mounting bracket to attach to the CO rack Figure 6 1 Position the HRM 238 shelf in the CO rack See Operational Capabilities on page 2 and Figure 2 on page 2 Figure 3 on page 3 or Figure 4 on page 3 for recommended placement Align the HRM 238 shelf mounting brackets with the vertical mounting holes on the CO rack Figure 6 Install the mounting hardware and secure Mounting bracket Security bracket Mounting bracket H0546 B Figure 6 Shelf with Brackets Positioned for 19 inch Rack INSTALLING FRAME GROUND AND BATTERY POWER Perform the following steps to install the 48 Vdc battery to the HRM 238 shelf and to connect battery common ground LGND and frame ground FGND The HRM 238 shelf terminal block has two connection points for supplying redundant battery capability Connect a 48 Vdc battery source to Terminal 1 48 to supply voltage to the HRM 238 shelf Table 2 on page 6 Connect another 48 Vdc battery source to Terminal 2 48V_B to supply redundant voltage to the HRM 238 shelf See Table 2 on page 6 for terminal block information 238 List 1 July 21 2004 5 Installation LTPH UM 1237 04 Table 2 Terminal Block TBI Terminal Description 1 48V_A 2 48V_B 3 BATTERY RETURN 4 FGND 1 Remove the fuse s in the equipment bay fuse panel for the circuit s where the HRM 238 shelf battery
13. _AUD_NC_A 2 CRIT_AUD_COM_A 14 MIN_AUD_COM_A 3 CRIT_AUD_NO_A 15 MIN_AUD_NO_A 4 CRIT_VIS_NC_A 16 MIN_VIS_NC_A 5 CRIT_VIS_COM_A 17 MIN_VIS_COM_A 6 CRIT_VIS_NC_A 18 MIN_VIS_NO_A 7 MAJ_AUD_NC_A 19 SYS_ID_NC_A 8 MAJ_AUD_COM_A 20 SYS_ID_COM_A 9 MAJ_AUD_NO_A 21 SYS_ID_NO_A 10 MAJ_VIS_NC_A 22 _ _ 11 VIS 23 LGND 12 MAJ_VIS_NO_A TURNING UP THE SYSTEM Perform the following procedures prior to installing the management unit s into the shelf Insert Fuse Insert an appropriately sized fuse s into the equipment bay fuse panel for the circuit s where the HRM 238 shelf battery wire s were terminated Refer to the appropriate management unit user manual for power consumption power dissipation and current drain HRM 238 List 1 July 21 2004 11 Installation LTPH UM 1237 04 Verify Cabling Verify the following 1 Verify a minimum of 42 and a maximum of 56 Vdc between the following 48 Vdc battery screw Terminal and the battery common Terminal 3 BATTERY RETURN b 48 battery screw Terminal 2 when used and the battery common Terminal 3 BATTERY RETURN 2 Visually verify that all connections are securely terminated Secure Cabling Tie the cable connectors to the back of the HRM 238 shelf using the tie wraps and mounting screws INSTALLING THE MANAGEMENT UNIT S 1 Install the management unit s into the HRM 238 shelf per procedures in the appropriate HMU 319 user manual
14. application 6 July 21 2004 HRM 238 List 1 1237 04 Installation Connect NMA Wiring From the 50 pin Amphenol connector P1 and or P6 Figure 8 wire directly to the pin 46 on the 220 type shelf backplane for each line unit being managed Route wires from the Pl and P6 connectors to the NMA 220 type mechanics shelves as shown in Figure 2 on page 2 Refer to Table 3 for Pl and connector information 50 pin Amphenol 50 pin Amphenol connector P6 connector P1 eh a 0O0000000000000000000000 0 0000000000000000000000 548 Figure 8 Connect Wiring 1 Remove the plastic cover from the 50 pin Amphenol connector and or P6 2 Install 50 female plug into the connector Separate the wires for each of the 50 pins For 220 type mechanics 3 Wire wrap the corresponding wire from the plug to pin 46 on the shelf for each line unit being managed The wire leads from the Amphenol plug can be up to 20 feet maximum For 3190 type mechanics 4 Wire wrap the corresponding wire from the plug to the pin 7 on the shelf for each line unit being managed The wire leads from the Amphenol plug can be up to 20 feet maximum For DDM type mechanics 5 Wire wrap or soldier depending on chassis manufacturer the corresponding NMA wire from the plug to the
15. e 800 366 3891 Systems Integration 800 366 3891 ADC Technical Assistance Center 800 366 3891 Email wsd_support adc com Online Technical Support Online Technical Publications Product Return Department 800 366 3891 Email repair return adc com Quotation Proposals Ordering and Delivery General Product Information Complete Solutions from concept to installation Network Design and Integration Testing System Turn Up and Testing Network Monitoring upstream or downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements Systems Operation Technical Information System Network Configuration Product Specification and Application Training product specific Installation and Operation Assistance Troubleshooting and Repair Field Assistance www adc com Knowledge_Base index jsp www adc com documentationlibrary technicalpublications Return Material Authorization number and instructions must be obtained before returning products All telephone numbers with 800 prefix are toll free in the USA and Canada July 21 2004 HRM 238 List 1 1237 04 APPENDIX 5 Co DCE DTE HCS HMU HRM LAN NMA PADs Bayonet Lockingl Connector Central Office Data Communication Equipment Data Terminal Equipment HiGain Card Shelf HiGain Management Unit HiGain Retrofit Management Local Area Network Netw
16. ork Management Agent Packet Assembler Disassemblers 238 List 1 July 21 2004 Appendix C Abbreviations 15 Appendix Abbreviations LTPH UM 1237 04 16 July 21 2004 HRM 238 List 1 CERTIFICATION AND WARRANTY FCC COMPLIANCE This equipment does not have any clocking source and is deemed to be a passive device per FCC guidelines When used in conjunction with any clocking devices this combined system may radiate radio frequency energy that can cause harmful interference to radio communications Operation of such a system in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own LIMITED WARRANTY Product warranty is determined by your service agreement Refer to the ADC Warranty Software Handbook for additional information or contact your sales representative or Customer Service for details MODIFICATIONS Any changes or modifications made to this device that are not expressly approved by ADC Telecommunicaitons Inc voids the user s warranty All wiring external to the products should follow the provisions of the current edition of the National Electrical Code World Headquarters ADC Telecommunications Inc PO Box 1101 Minneapolis Minnesota USA 55440 1101 Technical Assistance Tel 800 366 3891 DOCUMENT LTPH UM 1237 04 1299251
17. t Table 6 shows the pinouts for the two OS ports one port for each management unit Table 5 AUX P3 and 5 Connectors Pin Description 1 0 Pin Description 1 0 1 N C 14 N C 2 AUX_TX 0 15 N C 3 AUX_RX 16 N C 4 N C 17 N C 5 N C 18 N C 6 AUX_DSR 19 N C 7 LGND 20 AUX_DTR 0 8 N C 21 N C 9 N C 22 N C 10 N C 23 N C 11 N C 24 N C 12 N C 25 N C 13 N C Table 6 OS Port P2 and P4 Pin Description 1 0 Pin Description 1 0 1 N C 14 N C 2 05 0 15 05 TCLK 3 05 16 N C 4 OS_RTS 0 17 05 RCLK 5 0S_CTS 18 N C 6 0S_DSR 19 N C 7 LGND 20 0S DTR 0 8 N C 21 N C 9 N C 22 N C 10 N C 23 N C 11 N C 24 0S TCLK 12 N C 25 N C 13 N C For further details about connecting to the AUX OS connectors consult the appropriate user manual for the management unit and applicable software 10 July 21 2004 HRM 238 List 1 1237 04 Installation IDENTIFYING ALARMS Alarm relay contacts for each management unit are on J13 and J14 Figure 11 Install wiring between these pins and an alarm monitoring device per local practice Table 7 describes the alarm J13 and J14 pinouts DKI 9 00000000000000000000000 00000000000000000000000 H0651 A Alarm relay pins J14 Alarm relay pins J13 Figure 11 Alarm Relay Wire Wrap Pins Table 7 Alarm 713 714 Pinouts Pin Description Pin Description 1 CRIT_AUD_NC_A 13 MIN
18. t BOR PO HD gebe o RO ang 11 238 List 1 July 21 2004 vii List of Tables LTPH UM 1237 04 viii July 21 2004 238 List 1 1237 04 Overview OVERVIEW The HiGain HRM 238 List 1 is a two slot HiGain Retrofit Management HRM shelf This shelf fits into either a 19 or 23 inch Central Office CO equipment rack It accommodates up to two HiGain management units HMU 319s It is used in conjunction with 220 type unmanaged 3190 type and DDM type mechanic shelves to manage HiGain line units The HRM 238 shelf with two management units installed provides network management capabilities for a maximum of 56 HiGain line units 3190 DDM or two 220 shelves Each management unit in the HRM 238 shelf can manage up to 28 line units The HMU 319 management unit installs horizontally into the 4 34 inch slots labeled A or B on the HRM 238 shelf Figure 1 Each management unit connects to the shelf backplane through a 96 pin DIN connector 96 pin DIN 96 pin DIN connector J2 connector J4 H0543 A Figure HRM 238 List 1 front view FEATURES Standard features include 50 pin Amp type connectors for connection between the management units in the HRM 238 shelf and previously unmanaged HiGain line units in 220 3190 or DDM mechanics shelves DB 25 connectors for connection to a computer terminal or modem British Naval Connector
19. wire s will terminate 2 Connect one end of the frame ground wire to Terminal 4 FGND on of the HRM 238 shelf and attach the other end of the frame ground wire to the CO ground wire termination point 3 Connect the 48 CO battery to the HRM 238 shelf Figure 7 a Connect a wire to the HRM 238 shelf Terminal 1 48 for Primary CO battery b Connect a wire to the HRM 238 shelf Terminal 2 48V_B for Redundant CO battery Connect the battery common wire to HRM 238 shelf Terminal 3 BATTERY RETURN of the HRM 238 shelf and attach the other end to CO battery ground source s d Connect the wire s from the HRM 238 Terminal 1 and Terminal 2 to the CO 48 Vdc power termination point s Terminal 2 Terminal 4 to to 48 Vdc frame ground FGND C9 7 Terminal 1 Terminal 3 to battery to 48 Vdc common Battery Return Figure 7 Connect 48 Vdc and Frame Grounds to INSTALLING COMMUNICATION WIRING All wiring and connections for the HRM 238 shelf are on the back Figure 5 on page 4 shows the shelf backplane and connectors Connect the NMA wiring from the HRM 238 shelf to each HiGain Megabit Modem line unit that will be managed using the steps beginning on page 7 Then use the other connectors in Connect to a LAN or Interconnect Shelves on page 9 and Connect to a Computer Terminal or Modem page 9 that appropriate for your

Download Pdf Manuals

image

Related Search

Related Contents

  Manual de Usuario  CHAPES ET LIANTS  Leeway Harnesses  ADTRAN 1204002L1 User's Manual  K 113 ProMeat Kullanma con  Polaris 120 XC SP Offroad Vehicle User Manual  Swan STP100RED electrical kettle  *2013 年 10 月 17 日改訂(第 11 版) 医療機器承認番号  GUIDE DE L`UTILISATEUR  

Copyright © All rights reserved.
Failed to retrieve file