Home

8e6 Technologies ProxyBlocker MSA-004-005 User's Manual

image

Contents

1. This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations 8E6 PRoxYBLOCKER Quick START GUIDE 43 8e6 EC Declaration of Conformity European Community Directives Reguirement CE Declaration of Conformity Manufacturer s Name 8e6 Technologies Manufacturer s Address 828 W Taft Avenue Orange CA 92865 Application of Council Directive s Low Voltage 2006 95 EC EMC e 2004 108 EC Standard s Safety e EN60950 2006 EMC e EN55022 2006 e EN55024 1998 A2 2003 e EN61000 3 2 2000 e EN61000 3 3 2001 Product Name s Internet Appliance Product Model Number s MSA 004 005 Year in which conformity is declared 2008 All hardware components supplied in this unit s shipping carton are certified by our vendors to be RoHS compliant the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Location Orange CA USA Signature Date January 21 2008 Full Name Gregory P Smith Position Director of Engineering Operations 44 8 amp 6 ProxyYBLockeR Quick START GUIDE INDEX A Activate and Register the ProxyBlocker 38 B Boot Up 28 C crossover cable 19 28 36 E EMC 43 44 F FCC 43 H HyperTerminal Setup 21 ICES 003 43 L Login screen 24 Log in to ProxyBlocker Administrator Console 30 37 LVD 43 M MSA 20 28 42 43 P Physically Connect the ProxyBlocker to th
2. Initial Setup wizard Configure network interface LAN1 Configure network interface LAN2 Configure default gateway Configure DNS servers Configure host name Time Zone regional setting Reset system to factory defaults Reboot system Change administrator password 1 2 3 4 5 6 7 8 A B C Exit administration menu x Press the number of your selection A At the Press the number of your selection prompt press 2 to select the Initial Setup wizard process The wizard takes you to the following system configuration screens to make entries e Configure network interface LAN1 e Configure network interface LAN2 e Configure default gateway e Configure DNS servers e Configure host name e Time Zone regional setting LS NOTE See the Network screens for LAN Settings and Regional Setting in Step 1B for content included in the wizard screens B After making all entries using the wizard press X to return to the System Configura tion screen Or to verify the status of the ProxyBlocker and review the entries you made using the wizard press 1 to view the System Status screen LS NOTES Changing your password using option C Change administration password will change the password for the console menu but not the ProxyBlocker console login screen Option A Reset system to factory defaults should only be used by an 8e6 Technologies technical representative 8 amp 6 PRoxYBLOcKER Qui
3. Safety Compliance USA UL 60950 1 2nd ed 2007 Europe Low Voltage Directive LVD 2006 95 EC to CB Scheme EN 60950 2006 International UL CB to IEC 60950 1 2006 Electromagnetic Compatibility EMC USA FCC CFR 47 Part 15 Verified Class A Limit Canada IC ICES 003 Class A Limit Europe EMC Directive 2004 108 EC amp Low Voltage Directive LVD 2006 95 EC Federal Communications Commission FCC Class A Notice USA This equipment has been tested and found to comply with the limits for a Class A digi tal device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Declaration of Conformity Model MSA 004 005 Electromagnetic Compatibility Class A Notice Industry Canada Equipment Standard for Digital Equipment ICES 003 Cet appareil num rique de la classe A respecte toutes les exigences du R glement sure le mat riel brouilleur du Canada English translation of the notice above
4. To activate a default filter profile more appropriate for your operations or to specify a more limited IP range to filter consult Chapter 2 Group screen in the Global Adminis trator Section of the ProxyBlocker User Guide Refer to Chapter 1 System screen for information on how to give end users access to acceptable HTTPS sites if strict HTTPS filtering settings are used Obtain the latest ProxyBlocker User Guide at http www 8e6 com docs pba_ug pdf 8E6 PRoxYBLOcKER Quick START GUIDE 41 8e6 LED INDICATORS AND BUTTONS MSA Units Front LED Indicators and Buttons for Hardware Status Monitoring LED indicators and buttons for hardware status monitoring display on the front panel located on the right side of the chassis see diagram below E D C BA F G LED Indicator Key Button Key A Power F Reset ae B HDD Activity G Power one C LAN1 D LAN2 Chassis control panel E Overheat LED indicators alert you to the status of a feature on the unit while buttons let you per form a function on the unit LED Indicator Power Green System On Off System Off HDD Amber Blinking HDD Activity Off No HDD Activity LAN 18 LAN 2 Green On Link Connected Blinking LAN Activity Off Disconnected Overheat Red On System Overheated Off System Normal 42 8 6 PRoxYBLockeR Quick START GUIDE 8e6 REGULATORY SPECIFICATIONS AND DISCLAIMERS Declaration of the Manufacturer or Importer
5. Dangerous voltages associated with the 100 240 V AC power supply are present inside the unit To avoid injury or electrical shock do not touch exposed connections or components while the power is on To prevent damage to the server read the information in this document for selection of the proper input voltage Do not wear rings or wristwatches when troubleshooting electrical circuits To avoid fire hazard use only the specified fuse s with the correct type number volt age and current ratings Only qualified service personnel should replace fuses Qualified service personnel should be properly grounded when servicing the unit Qualified service personnel should perform a safety check after any service is per formed 8E6 PRoxYBLOCKER Quick START GUIDE 17 8e6 Motherboard Battery Precautions Caution The battery on the motherboard should not be replaced without following instructions provided by the manufacturer Only gualified service personnel should replace batteries The battery contains energy and as with all batteries a malfunction can cause heat smoke or fire release toxic materials or cause burns Do not disassemble puncture drop crush bend deform submerge or modify the battery Do not incinerate or expose to heat above 140 F 60 C There is a danger of explosion if the battery on the motherboard is installed upside down which will reverse its polarities CAUTION DANGER OF EXPLOSION IF BATTE
6. From the navigation panel click Network and choose Regional Setting from the pop up menu ProxyBlocker 15 x 8e6 ProxyBlocker HOME SYSTEM GROUP LIBRARY REPORTING HELP Ob ii Regional Setting System gt Network gt Regional Setting Administrator Time Zone Diagnostics Region JUS z Location Eastern ba Alert Patch Language Mode Authentication Language English United States en_US ha NIC Mode Backup Restore Reset SNMP Hardware Failure Detection X Strikes Blocking Warn Option Setting Customization Warning This will Reboot the ProxyBiocker system Host Name logo com IP 200 10 100 75 Wrersion ProxyBlocker 1 0 00 4 Java Applet Window Make the following selections in the Regional Setting window A At the Region pull down menu select your country from the available choices 8E6 PRoxYBLOCKER Quick START GUIDE 35 8e6 B Atthe Location pull down menu select the time zone for the specified region If necessary select a language set from the Language pull down menu to display that text in the console C Click Apply to apply your settings and to reboot the ProxyBlocker Physically Connect the ProxyBlocker to the Network Once your ProxyBlocker network parameters are set you must physically connect the unit to your network This step requires two standard CAT 5E cables LS NOTE This section requires you to restart the ProxyBlocker If you wish to relocate the Pr
7. GUIDE 39 Monitor the Library Update Process To verify that the library is being updated A From the navigation panel click Updates and select Library Update Log from the menu B In the Library Update Log window click View Log to display the update activity i ia 8e6 ProxyBlocker es eS HOME SYSTEM GROUP LIBRARY REPORTING HELP Od fe Library Update Log Library gt Updates gt Library Update Log Category Weight System Download Log NNTP Newsgroup Category Groups ue Feb 20 12 16 05 PST 2007 18955 Start library reload ue Feb 20 12 18 13 PST 2007 18955 Complete library reload ye Feb 20 12 23 08 PST 2007 30340 Start library reload ue Feb 20 12 25 23 PST 2007 30340 Complete library reload ue Feb 20 14 26 09 PST 2007 32481 Start library reload ue Feb 20 14 28 08 PST 2007 9835 Start library reload ye Feb 20 14 30 32 PST 2007 9835 Complete library reload ue Feb 20 14 54 07 PST 2007 28584 Start library reload ue Feb 20 14 57 09 PST 2007 2121 Start library reload ue Feb 20 14 59 19 PST 2007 2121 Complete library reload ue Feb 20 14 59 49 PST 2007 3074 Downloading full library update ue Feb 20 14 59 59 PST 2007 3074 Full library update has completed ue Feb 20 14 59 59 PST 2007 3074 Final update status Failed with the Following errors rror messages encountered ailed to login ailed to download impattern impat sind ailed to download ptoppattern ptoppat ind ailed to download proxy
8. Internet Explorer from the setup workstation B Type in http 1 2 3 4 88 in the address field C Click Go to open the ProxyBlocker Introductory Window B i x File Edit View Favorites Tools Help ay Q x Q x a A J search y Favorites amp fa on Address http 200 10 101 109 86 PB4 PBA htm z Go a Press SPACEBAR or ENTER to activate and use this control 8e6 ProxyBlocker Note Please keep this window open throughout your session How to Log In to the Administrator GUI 1 Enter your Username and Password in the Login dialog box 2 Click OK to close the login dialog box and to access the welcome screen of the Administrator GUI The Administrator GUI is used for making configurations in the System Group Library and Reporting areas of the ProxyBlocker server Click the button corresponding to one of these topics to access configuration windows within that section of the GUI Click Help for more information on navigating the Administrator GUI Click Home to return to the welcome screen How to Log Out of the Administrator GUI 1 Click Quit in the navigational bar on any screen in the Administrator GUI to end your session and to close the GUI 2 Click the X in the upper right corner of this ProxyBlocker Introductory Window to close the window zi 4 Applet com r3000 qui applet AdminApplet started ff E internet L NOTE This window must be left open thro
9. as this often occurs when there is a change in the IP address To restart the browser window close both the ProxyBlocker Administrator console and the ProxyBlocker Introductory Window Begin a new session by opening a new browser window and then logging back into the Administrator console 36 8 6 PRoxYBLockeR Quick START GUIDE 8e06 Step 2 Test the ProxyBlocker Console Connection Now that the ProxyBlocker is physically installed on your network and you have config ured its network settings you need to test the unit to see if it is set up properly A Restore the setup workstation you used for the Network Setup to its original settings and connect it to the network hub to create a network workstation You could also use another workstation already on the network that has Internet access B Launch IE on the network workstation and enter the IP address you assigned to LAN 1 Step 1A System Configuration Administration menu or Step 1B Network LAN Settings sub step B Be sure to include the port information 88 in the address field For example if the ProxyBlocker were assigned an IP address of 10 10 10 10 you would enter http 10 10 10 10 88 in the browser window s address field C Click Go You should be prompted to log into the Administrator console giving the Username and Password If you can access the ProxyBlocker Administrator console the ProxyBlocker is function ing on your network and you should pr
10. for the connection lx Name p Icon B In the Connection Description dialog box enter any session Name and then click OK to open the Connect To dialog box ConnectTo TES B R3000MSA Enter details for the phone number that you want to dial Country region United States of America 1 z Area code 714 Phone number Connect using 7 Cancel 8E6 PRoxYBLOCKER Quick START GUIDE 21 8e6 C At the Connect using field select the COM port assigned to the serial port on the laptop probably COM1 and then click OK to open the Properties dialog box dis playing the Port Settings tab COM1 Properties Hardware D Specify the following session settings e Bits per second 9600 e Data bits 8 e Parity None e Stop bits 1 e Flow control Hardware E Click OK to connect to the HyperTerminal session 22 8 amp 6 ProxYBLockerR Quick START GUIDE 8e6 F In the HyperTerminal session window go to File gt Properties to open the Properties dialog box displaying the Connect To and Settings tabs R3000MSA Properties 213 ConnectTo Settings m Function arrow and ctrl keys act as Terminal keys Windows keys m Backspace key sends CtkH Del Ctri H Space Ctri H Emulation Terminal Setup Telnet terminal ID T 00 Backscroll buffer lines 500 Play sound when connecting or disconnecting Input Tr
11. length of the rails accordingly Repeat the same steps to install the other outer rail on the chassis Secure both outer rail assemblies to the rack with Type H screws and Type wash ers See the previous page for descriptions of Type H and Type hardware compo nents BS 8E6 PRoxYBLOCKER Quick START GUIDE 9 8e6 7 Slide the chassis into the rack as shown below LS NOTE The chassis may not slide into the rack smoothly or easily when installed the first time Some adjustment to the slide assemblies might be needed for easy installation 8 You will need to release the safety taps on both sides of the chassis in order to com pletely remove the chassis out of the rack 10 8 E6 PROXxYBLOCKER QUICK START GUIDE 8e6 Optional Install the Open Racks After you have installed the inner rails on the chassis you are ready to install the outer rails of rail assemblies to the rack LS NOTE The rails are designed to fit in the racks with the depth of 28 to 33 e Determine the placement of each component in the rack before you install the rails e Install the heaviest server components on the bottom of the rack first and then work up 1 In the package locate a pair of front short and rear long brackets Please note that the brackets are marked w
12. rail to each side of the chassis and secure the inner rail to the chas sis by inserting three Type G screws through the holes on each side of the chassis and the inner rail See the diagram below for a description of the Type G screw ja T oa F CC G Round head M4 x 4 mm 0 157 H Flat head M5 x 12 mm 0 472 Washer for M5 5 Repeat the above steps to install the other rail on the chassis 8E6 PROXxYBLOCKER Quick START GUIDE 8e6 Optional Install the Traditional UP Racks After you have installed the inner rails on the chassis you are ready to install the outer rails of rail assemblies to the rack LS NOTE The rails are designed to fit in the racks with the depth of 28 to 33 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up In the package locate a pair of front short and rear long brackets Please note that the brackets are marked with Up Front Arrows front and Up Rear arrows rear Secure the front short bracket marked with the Up Front arrows to the outer rail with two Type G screws See the previous page for a description of the Type G screw Attach the rear long bracket to the other end of the outer rail and secure the rear long bracket to the outer rail with a Type G screw as shown below Measure the depth of your rack and adjust the
13. server 8E6 PRoxYBLOCKER Quick START GUIDE 31 8e6 32 Network Operation Mode From the navigation panel at the left of the screen click Mode and choose Operation Mode from the pop up menu En aLcil xl 8e6 ProxyBlocker eee jl OE Administrator Diagnostics Alert Patch ode Authentication NIC Mode BackupRestore Reset SNMP Hardware Failure Detection X Strikes Blocking Warn Option Setting Customization LIBRARY REPORTING HELP WOUN Operation Mode System gt Mode gt Operation Mode Listening Device Device feam ha Block Page Delivery Method Protocol Methods Block Page Device Device to send block page ILANI Send Block Page via ARP Table Send Block to Specified Host MAC Address Block Page Route To Default Gateway C Alternate IP Address gt Current MAC Address 00 15 60 22 C4 00 Host Name logo com IP 200 10 100 75 version ProxyBlocker 1 0 00 4 Java Applet Window Make the following entries in the Operation Mode window A In the Listening Device frame select the device for listening to traffic generally LAN1 B In the Block Page Device frame select the device for sending block pages to client PCs The block page device should be a different device than the one selected in the Listening Device frame LAN2 is generally used as the default device for sending block pages C Click Apply 8 E6 PROXxYBLOCKE
14. E Seb SERVICE INFORMATION The user should not attempt any maintenance or service on the unit beyond the proce dures outlined in this document Any initial hardware setup problem that cannot be resolved at your internal organiza tion should be referred to an 8e6 Technologies solutions engineer or technical support representative 8e6 Corporate Headquarters USA Local 714 282 6111 Domestic US 1 888 786 7999 International 1 714 282 6111 8e6 Taiwan Taipei Local 2397 0300 Domestic Taiwan 02 2397 0300 International 886 2 2397 0300 Procedures When calling 8e6 Technologies regarding a problem please provide the representative the following information 8 amp 6 PRoxYBLOCKER Quick START GUIDE Your contact information Serial number or original order number Description of the problem Network environment in which the unit is used State of the unit before the problem occurred Frequency and repeatability of the problem Can the product continue to operate with this problem Can you identify anything that may have caused the problem 8e6 PRELIMINARY SETUP PROCEDURES Unpack the Unit from the Carton Inspect the packaging container for evidence of mishandling during transit If the packag ing container is damaged photograph it for reference Carefully unpack the unit from the carton and verify that all accessories are included Save all packing materials in the event that the unit needs to
15. R QUICK START GUIDE 8e6 Network LAN Settings From the navigation panel click Network and choose LAN Settings from the pop up menu Hox i8e6 ProxyBlocker mn HOME SYSTEM GROUP LIBRARY REPORTING HELP QUIT LAN Settings System gt Network gt LaN Settings Administrator Host Name fgoscm S Diagnostics IP Mask Setting Alert Patch LAN IP 200 10 101 109 255255255192 v Mode Authentication tanze fi2zse v oo NIC Mode BackupRestore Reset SNMP Primary IP 200 10 100 8 Hardware Failure Detection X Strikes Blocking Secondary IP 200 10 100 9 Warn Option Setting Customization Gateway Gateway IP 200 10 101 129 Apply Host Name logo com IP 200 10 100 75 Prersion ProxyBlocker 1 0 00 4 Java Applet Window Make the following entries for the ProxyBlocker in the LAN Settings window A Enter the Host Name that includes your domain name for example PBASERVER myserver com the NetBIOS name must be capitalized It is important to enter something identifiable because once the product is registered this host name is used by 8e6 Technologies to recognize your account for library updates This name needs to be a valid DNS entry B Enter the LAN1 IP address and specify the subnet for LAN 1 the ProxyBlocker s first Ethernet Network Interface Card NIC You may use a non routeable IP address for the listening interface and a subnet mask of 255 255 255 255 32 bites C Ente
16. RY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISPOSE OF THE USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS ATTENTION IL Y ADANGER D EXPLOSION S IL Y A REPLACEMENT INCORRECT DE LA BATTERIE REMPLACER UNIQUEMENT AVEC UNE BATTERIE DU MEME TYPE OU D UN TYPE EQUIVALENT RECOMMANDE PAR LE CONSTRUCTEUR METTRE AU REBUT LES BATTERIES USAGEES CONFORMEMENT AUX INSTRUC TIONS DU FABRICANT 8 6 PRoxYBLockerR Quick START GUIDE Se6 INSTALL THE SERVER Step 1 Setup Procedures This step requires you to link the workstation to the ProxyBlocker You have the option of using the text based wizard setup procedures described in Step 1A or the Administrator console setup procedures described in Step 1B Wizard Setup Requirements The following hardware can be used for the wizard setup procedures e ProxyBlocker with AC power cord e either one of two options e PC monitor with AC power cord and keyboard or e PC laptop computer with HyperTerminal and serial port cable and USB DB9 se rial adapter if there is no serial port on your laptop Go to Step 1A to execute Wizard Setup Procedures Administrator Console Setup Requirements The following hardware is required for the Administrator console setup procedures e ProxyBlocker unit with AC power cord e CAT 5E crossover cable e PC laptop computer or PC monitor with AC power cord and keyboard Go to Step 1B to exe
17. aa 8e0 ProxyBlocker 8e6 Technologies QUICK START GUIDE Model ProxyBlocker MSA 004 005 Release 1 0 00 Updated 02 11 08 8e6 8E6 PROXYBLOCKER QUICK START GUIDE 2008 8e6 Technologies All rights reserved This document may not in whole or in part be copied photocopied reproduced translated or reduced to any elec tronic medium or machine readable form without prior written consent from 8e6 Technologies Every effort has been made to ensure the accuracy of this document However 8e6 Technologies makes no war ranties with respect to this documentation and disclaims any implied warranties of merchantability and fitness for a particular purpose 8e6 Technologies shall not be liable for any error or for incidental or consequential damages in connection with the furnishing performance or use of this manual or the examples herein The information in this documentation is subject to change without notice Trademarks Other product names mentioned in this manual may be trademarks or registered trademarks of their respective com panies and are the sole property of their respective manufacturers Part PBA MSAul QSG 080211 8E6 PROXxYBLOCKER QUICK START GUIDE CONTENTS 8E6 PROXYBLOCKER INTRODUCTION ccesceccecsucceceuseccuscuceueeusaueueeeeeuseuseuseeeueenees 1 About this DOCUMENT sawasawa 2 Conventions Used in this DOCUMENt ccccsccesceesseeeseeeensseesenesseeauseeensuseeenusseuauesennaueesen
18. ack e Make sure that the system is adequately supported Make sure that all the components are securely fastened to the chassis to prevent components fall ing off from the chassis e The rack assembly should be properly grounded to avoid electric shock e The rack assembly must provide sufficient airflow to the chassis for proper cooling e Please make sure that all components and all chassis covers are properly in stalled in the chassis before you install the chassis into the racks otherwise out of warranty damage may occur Slide the chassis into the rack and secure it with two screws on each side of the rack as shown in the picture slide into rack and secure with two screws on each side 8 E6 PROXxYBLOCKER QUICK START GUIDE 8e06 Check the Power Supply This server is eguipped with a universal power supply that handles 100 240 V 50 60 Hz A standard power cord interface IEC 950 facilitates power plugs that are suitable for most European North American and Pacific Rim countries Power Supply Precautions A Warning e Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep the server operating in case of a power failure e In geographic regions that are susceptible to electrical storms 8e6 highly recom mends plugging the AC power cord for the server into a surge suppressor e Use appropriately rate
19. ack to become unstable 8E6 ProxYBLOCKER Quick START GUIDE 8e6 Rack Mount Instructions Optional Install the Chassis Rails LS NOTE If your chassis does not come with chassis rails please follow the procedure listed on the last page of this sub section to install the unit directly into the rack CAUTION Please make sure that the chassis covers and chassis rails are installed on the chassis before you install the chassis into the rack To avoid personal injury and property damage please carefully follow all the safety steps listed below Before installing the chassis rails e Close the chassis using the chassis cover e Unplug the AC power cord s e Remove all external devices and connectors 1 Included in the shipping package are a pair of rail assemblies In each rail assembly locate the inner rail and the outer rail 2 Press the locking tab to release the inner rail from its locking position and pull out the inner rail from the rail assembly L NOTE The inner rails are to be attached to the chassis and the outer rails are to be installed in the rack Outer rail to be installed in the rack Pull out the Inner rail to be attached on the chassis Press the Locking Tab 8E6 PRoxYBLOCKER Quick START GUIDE 7 8e6 3 Locate the three holes on each side of the chassis and locate the three correspond ing holes on each of the inner rail 4 Attach an inner
20. anslation ASCII Setup G Click the Settings tab and at the Emulation menu select VT100 H Click OK to close the dialog box and to go to the login screen LS NOTE If using a HyperTerminal session the login screen will display with black text on a white background 8E6 PRoxYBLOcKER Quick START GUIDE 23 8e6 Login screen The login screen displays after powering on the ProxyBlocker unit LS NOTE If the screensaver currently displays on your screen press the Enter key to display the login screen A At the login prompt type in menu B Press the Enter key to display the Password prompt C At the Password prompt type in the following s3tup r3k D Press Enter to display the System Configuration screen System Configuration Screen Tue Jul 25 14 64 53 PDT 2666 8e6 Technologies System Configuration Display Status Enter administration password Press the number of your selection A At the Press the number of your selection prompt press 2 to select the setup pro cess for the System Configuration wizard B At the login prompt re enter your password s3tup r3k C Press Enter to display the Administration menu where you can begin using the Sys tem Configuration wizard 24 8 6 PRoxYBLockerR Quick START GUIDE Seb System Configuration Administration menu Tue Jul 25 14 05 16 PDT 2666 8e6 Technologies System Configuration Administration menu Display Status
21. be open on your network to allow access by remote technical support Step 4 Set Library Updates After verifying that the ProxyBlocker is correctly installed on your network you need to activate ProxyBlocker library updates Library updates are critical for filtering as new sites are added to the 8e6 library each day To activate updates visit the 8e6 Technolo gies Web site and enter the activation code that was issued to you by e mail also includ ed on the product invoice L NOTE Ports 20 and 21 FTP must be open for outgoing requests so that the ProxyBlocker can receive library updates Activate and Register the ProxyBlocker 38 Be sure you have a valid host name chosen before activating your account A Open an Internet browser window and go to http www 8e6 com activate B After reading through the online End User License Agreement click Accept to go to Step 2 of the activation process C Enter your activation code D Click Submit to go to the ProxyBlocker Activation and Registration page E Verify that your serial number and activation code are the same as shown on this registration page F Fill out the information on this page including the host name for the public DNS server The entry of the unique host name you ve chosen is mandatory in order to receive library updates G After all information is entered click Activate to activate your service You should receive confirmation that the ProxyBlo
22. be returned to 8e6 Tech nologies The carton should contain the following items e 1 ProxyBlocker unit e 1 AC Power Cord e 1 Serial Port Cable e 1 CAT 5E Crossover Cable e Rack Mount Brackets 2 e 1 End User License Agreement EULA e 1 envelope containing a CD ROM with PDFs of the ProxyBlocker User Guide and ProxyBlocker Authentication User Guide The latest version of the ProxyBlocker User Guide can be obtained from our Web site at http www 8e6 com docs pba_ug pdf The latest version of the ProxyBlocker Authentication User Guide can be obtained from our Web site at http www 8e6 com docs pba_auth_ug pdf LS NOTES A coupler is included in the carton if a three foot CAT 5E crossover cable was packaged with your unit instead of a 14 foot CAT 5E crossover cable Inspect the server and accessories for damage If the contents appear damaged file a damage claim with the carrier immediately A WARNING To avoid danger of suffocation do not leave plastic bags used for packaging the server or any of its components in places where children or infants may play with them 4 8E6 ProxyBLOcCKER Quick START GUIDE Se6 Select a Site for the Server The server operates reliably within normal office environmental limits Select a site that meets the following criteria e Clean and relatively free of excess dust e Well ventilated and away from sources of heat with the ventilating openings on the server kept free of o
23. bstructions e Away from sources of vibration or physical shock e Isolated from strong electromagnetic fields and noise caused by electrical devices such as elevators copy machines air conditioners large fans large electric motors radio and TV transmitters and high frequency security devices e Access space provided so the server power cord can be unplugged from the power supply or the wall outlet this is the only way to remove the AC power cord from the server e Clearance provided for cooling and airflow Approximately 30 inches 76 2 cm in the back and 25 inches 63 5 cm in the front e Located near a properly earthed grounded power outlet 8 amp 6 PRoxYBLOCKER Quick START GUIDE 5 8e6 Rack Mount the Server Rack Setup Precautions A warning Before rack mounting the server the physical environment should be set up to safely ac commodate the server Be sure that The weight of all units in the rack is evenly distributed Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading The rack will not tip over when the server is mounted even when the unit is fully extended from the rack For a single rack installation stabilizers are attached to the rack For multiple rack installations racks are coupled together Reliable earthing of rack mounted equipment is maintained at all times Particular attention should be given to supply con
24. ck START GUIDE 25 Se6 System Status Screen Tue Jul 25 14 05 16 PDT 2666 8e6 Technologies System Status updates every 18 seconds LAN1 is the Capturing Interface LAN1 IP 1 2 3 4 Mask 255 255 255 255 LAN2 is the Management and Blocking Interface LAN2 IP 200 10 160 74 Mask 255 255 0 0 Default gateway IP 266 16 166 1 ProxyBlocker host name logo con DNS server IP address es 2660 160 166 1 Regional timezone setting US Pacific ProxyBlocker processing is initializing Current Version ProxyBlocker 1 6 66 8 Library was last updated on 2607 66 15 Press any key to return to menu The System Status screen contains the following information e Capturing Interface specified in screen 3 Configure network interface LAN1 e LANT1 IP address and netmask specified in screen 3 and current status Active or Inactive e Management and Blocking Interface specified in screen 4 Configure network inteface LAN2 e LANZ2 IP address and netmask specified in screen 4 and current status Active or Inactive e Default gateway IP address specified in screen 5 Configure default gateway e ProxyBlocker host name specified in screen 7 Configure host name e DNS server IP address es specified in screen 6 Configure DNS servers e Regional timezone setting specified in screen 8 Time Zone regional setting e Current status of the ProxyBlocker e Current ProxyBlocker software Version installed e Librar
25. cker at your host name has been activated 8 amp 6 PRoxYBLOCKER Quick START GUIDE 8e6 You may wish to print the confirmation page for future reference in dealing with tech nical issues Perform a Complete Library Update Your ProxyBlocker was shipped with the latest library update for the current software release However as new updates continually become available before you begin using the ProxyBlocker you must perform a complete library update to ensure you have the latest library updates To download the latest library updates go to the ProxyBlocker Administrator console A Click the Library button at the top of the screen B From the navigation panel click Updates and select Manual Update from the menu zox 8e6 ProxyBlocker Ss 1 ONES SYSTEMS ORO UAS L DRARYS SRERORTINGS SH E ERa SO Wia m Manual Update to 8e6 Supplied Categories Library gt Updates gt Manual Update to 8e6 Supplied Categories Library Lookup Opti i ptions Category Weight System NNTP Newsgroup Weekly Update Patch Update f Category Groups T op il he UR hi jular upda C Full URL Library Update sption wil 2 the ill also inc sgroup libra Host Name logo com IP 200 10 100 75 Wrersion ProxyBlocker 1 0 00 4 Java Applet Window C In the Manual Update to 8e6 Supplied Categories window click the radio button cor responding to Full URL Library Update D Click Update Now to begin the update process 8E6 PRoxYBLOCKER Quick START
26. cute Console Setup Procedures 8 amp 6 PRoxYBLOCKER Quick START GUIDE 19 8e6 Step 1A Wizard Setup Procedures Link the Workstation to the ProxyBlocker Monitor and Keyboard Setup A Connect the PC monitor and keyboard cables to the rear of the chassis BERS wa LAN1 Fig 1 Portion of chassis rear B Turn on the PC monitor C Power on the ProxyBlocker by dropping down the face plate and pressing the large button at the right of the front panel see Fig 2 Fig 2 Diagram of chassis front panel power button at far right Once the ProxyBlocker is powered up proceed to the Login Screen instructions Serial Console Setup A Using the serial port cable and USB DB39 serial adapter if necessary connect the laptop to the rear of the chassis see Fig 1 B Power on the laptop C Power on the ProxyBlocker by dropping down the face plate and pressing the large button at the right of the front panel see Fig 2 Once the ProxyBlocker is powered up proceed to the instructions for HyperTerminal Setup Procedures 20 8 E6 PROXxYBLOCKER QUICK START GUIDE 8e6 HyperTerminal Setup Procedures If using a serial console follow these procedures to create a HyperTerminal session on the serial console A Launch HyperTerminal by going to Start gt Programs gt Accessories gt Communica tions gt HyperTerminal Connection Description k 2 ay New Connection Enter a name and choose an icon
27. d extension cords or power strips only e Allow power supply units to cool before touching them 8E6 PRoxYBLOcKER Quick START GUIDE 15 8e6 General Safety Information Server Operation and Maintenance Precautions A Warning Observe the following safety precautions during server operation and maintenance A WARNING If the server is used in a manner not specified by the manufacturer the protection provided by the server may be impaired A WARNING 8e6 Technologies is not responsible for regulatory compliance of any server that has been modified Altering the server s enclosure in any way other than the installation operations specified in this document may invalidate the server s safety certifications CAUTION Never pile books papers or other objects on the chassis drop it or subject it to pressure in any other way The internal circuits can be damaged and the battery may be crushed or punctured Besides irreparable damage to the unit the result could be dangerous heat and even fire caution There are no user serviceable components inside the chassis The chassis should only be opened by qualified service personnel Never disas semble tamper with or attempt to repair the server Doing so may cause smoke fire electrical shock serious physical injury or death e Do not insert objects through openings in the chassis Doing so could result in a short circuit that might cause a fire or an e
28. e Network 36 Power Supply Precautions 15 R R3000 1 Rack Setup Precautions 6 reboot 31 36 RoHS compliant 44 S serial port cable 4 19 20 shut down 36 8E6 PRoxYBLOCKER Quick START GUIDE 8e6 45 8e6 UL 43 W wizard setup 19 26 46 8E6 PROXxYBLOCKER Quick START GUIDE 8E6 PRoxYBLOcKER Quick START GUIDE Se6 47 8e6 Corporate Headquarters USA 828 West Taft Avenue Orange CA 92865 4232 Tel 714 282 6111 or 888 786 7999 Fax 714 282 6116 Sales Technical Support e 714 282 6117 General Office Satellite Office 8e6 Taiwan 7 FI No 1 Sec 2 Ren Ai Rd Taipei 10055 Taiwan R O C Tel 886 2 2397 0300 Fax 886 2 2397 0306
29. es 38 CONCLUSION ac bis tie sun mzaa anana nanu nanu w umaana veeceeeicausewupscsaremsedcenandiseseeeaascetaneuens 41 LED INDICATORS AND BUTTONS cesceccesceccuccuseccuscuceueeueeueeeeuceuseueeuseeeueeueeeses 42 MSA US vein a E E E E shit cansnnnctcen E E couse sane A E A A E E 42 REGULATORY SPECIFICATIONS AND DISCLAIMERS ceescescceccesceeceeceueceeececeeeeeees 43 Declaration of the Manufacturer or Importer 2 ccceceseeeeee cence eee eeeeeeeeeaeeeeeeseeeeeeeeeeeeeseeaneeeees 43 INDEX EFA e SA MAIDA DE MENO MOVE OPEN WALA KANA AAE 45 8 amp 6 PRoxYBLOCKER Quick START GUIDE 8e6 IV 8 6 PROXxYBLOCKER QUICK START GUIDE Se6 8E6 PRoxyYBLOCKER INTRODUCTION Thank you for choosing to evaluate the 8e6 Technologies ProxyBlocker The Proxy Blocker offers a solution for organizations using an Internet filtering product other than 8e6 s R3000 Enterprise Filter 8e6 ProxyBlocker tracks each user s online activity of Web based proxies and anonymizers and can be configured to block specific Web sites or service ports thereby protecting your organization against lost productivity network bandwidth issues and possible legal problems that can result from the misuse of Inter net resources 8 amp 6 PRoxYBLOCKER Quick START GUIDE 1 8e6 About this Document This documentis divided into the following sections Introduction This section is comprised of an overview of the ProxyBlocker product and how to use this docume
30. esesnaness 2 SERVICE INFORMATION cescecceccecceceuceecescuceuseueeusneeseueeueeuseuceeeeeeeecueeuseuseueensenes 3 PRELIMINARY SETUP PROCEDURES sscesceeccesceeceecceeceecceceeeccecceceenececeeseeneeueeeneues 4 Unpack the Unit from the Carton cccccccccscecssscensssceescccesecescasseenasteeceeesnadsacwsesscctacueensseeeeennveseanennazes 4 Select a Site for the Server u cccsccecceeesccssseueessececueeseuauesuensueeeaueseeeausseenaueeeaueseseaueseanausueeeeseseauses 5 Rack Mount the Server cccccccsseseccsseseceeseseaueeeeeseeeuneeeauaueeeenauesenussuaeauuseeauuesuaussuseneusesauueeenassesenes 6 Check the Power Sup ply wisi cicccvsicssccececccce cececdecatacancescenescvecscesesenvsanaanenved s cevtved cas sennasteeeeesvved cdeveneve 15 General Safety Informatio M WI 16 INSTALL THE SERVER sccwcaissiccideperctaceccudad shacks cddctawiepaneoitdetantweccnsdtecendubbacddaceuce 19 Step 1 Setup PRO US AA EE A EEEE EE 19 Step 1A Wizard Setup Procedures c ce sceeeeeeceeeeee eee eeeeeeeeeaeeeeeeeeeeeeneseneseaaeaeeeeseeeeeesneeeeeees 20 Step 1B Console Setup Procedures cc seseeecceeeeeeeeeeeeeeeaseaneeeseeeeeeseeseseseaaeaeeeeseeeeeeseeneeeees 27 Step 2 Test the ProxyBlocker Console Connection ccceecccceeeeeneeeeeeeeeseeeeeeeenseeeeseenseeeeeeeaes 37 LSP 3 TESH Fite mn AAA 38 Step 4 Set Library Updates eccccccccceeceeeeeseeeeeee cee nuna eee sees seaseaaeeeseeeeeeeeeseeesaseeaneeseseeeeeeeeeeee
31. ion NIC Mode Backup Restore Reset SNMP Hardware Failure Detection X Strikes Blocking Warn Option Setting Customization NTP Server Add System Time System Current Time 2007 06 04 15 56 50 EDT 0400 Host Name logo com IP 200 10 100 75 Wrersion ProxyBlocker 1 0 00 4 Java Applet Window The NTP Servers window is used for specifying the Network Time Protocol NTP serv ers to be used by the ProxyBlocker so that the ProxyBlocker is synchronized with com puter clocks on the Internet Note that the following server IP addresses display in the Servers list box 128 59 35 142 142 3 100 15 129 132 98 11 If necessary any of these servers can be deleted by selecting the IP address and clicking Delete 8E6 PROXxYBLOCKER QuICK START GUIDE 8e6 LS NOTE If you need to find another NTP server to use most university Web sites provide these servers for public usage A Inthe NTP Server field enter the IP address of the primary NTP server you wish to use for clock settings on your server B Click Add to include this IP address in the Servers list box C Enter two more NTP servers following the procedures in sub steps A and B These will be the secondary and tertiary NTP servers in order as they appear in the list box D Click Apply L NOTE If the primary server fails the secondary will be used If the secondary server fails the tertiary server will be used Network Regional Setting
32. ith Up Front Arrows front and Up Rear arrows rear 2 Secure the front short bracket marked with the Up Front arrows to the outer rail with two Type G screws as shown below gt p eg G Round head M4 x 4 mm 0 157 H Flathead M5 x 12 mm 0 472 Washer for M5 o 8E6 PRoxYBLOCKER Quick START GUIDE 11 8e6 3 Attach the front short bracket to the front end of the rack and secure it to the rack with two Type H screws and Type washers as shown below See the previous page for descriptions of Type H and Type hardware components 4 Attach the rear long bracket to the rear end of the rack and secure it to the rack with two Type H screws and Type washers as shown below Repeat the same steps to install the other outer rail to the other side of rack 5 Measure the depth of your rack and adjust the length of the rails accordingly Then secure the rails to the chassis with Type G screws 12 8 amp 6 ProxyYBLockeR Quick START GUIDE 8e6 6 Slide the inner rails which are attached to the chassis into the outer rails on the rack 8E6 PRoxYBLOcKER Quick START GUIDE 13 8e6 Install the Chassis into the Rack O CAUTION Before installing the chassis into the rack e Make sure that the rack is securely anchored onto an unmovable surface or structure before installing the chassis into the rack e Unplug power cord s of the rack before installing the chassis into the r
33. lectrical shock e Do not operate the server in an explosive atmosphere in the presence of flammable gases e To ensure proper cooling always operate the server with its covers in place Do not block any openings on the chassis Do not place the server near a heater e Always exit the software application properly before turning off the server to ensure data integrity e Do not expose the server to rain or use near water If liquids of any kind should leak into the chassis power down the server unplug it and contact 8e6 Technologies technical support e Disconnect power from the server before cleaning the unit Do not use liquid or aero sol cleaners 8 6 PRoxYBLockeR Quick START GUIDE 8e06 AC Power Cord and Cable Precautions A Warning The AC power cord for the server must be plugged into a grounded power outlet Do not modify or use a supplied AC power cord if it is not the exact type required in the region where the server will be installed and used Replace the cord with the cor rect type Route the AC power cord and cables away from moving parts and foot traffic Do not allow anything to rest on the AC power cord and cables Never use the server if the AC power cord has been damaged Always unplug the AC power cord before removing the unit for servicing Electrical Safety Precautions A Warning Heed the following safety precautions to protect yourself from harm and the server from damage CAUTION
34. nections other than direct connections to the branch circuit e g use of power strips A power cord will be long enough to fit into the server when properly mounted in the rack and will be able to supply power to the unit The connection of the server to the power supply will not overload any circuits Con sideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern The server is only connected to a properly rated supply circuit Reliable earthing grounding of rack mounted equipment should be maintained The air flow through the server s fan or vents is not restricted Installation of the equipment in a rack should be such that the amount of air flow required for safe op eration of the equipment is not compromised The maximum operating ambient temperature does not exceed 104 F 40 C If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer A WARNING Extend only one component at a time Extending two or more components simultaneously may cause the r
35. nt Service Information This section provides 8e6 Technologies contact information Preliminary Setup Procedures This section includes instructions on how to physi cally set up the ProxyBlocker in your network environment Install the Server This section explains how to configure the ProxyBlocker for filtering Conclusion This section indicates that the quick start steps have been completed LED Indicators and Buttons This section explains how to read LED indicators and use LED buttons for troubleshooting the unit Regulatory Specifications and Disclaimers This section cites safety and emis sions compliance information for the ProxyBlocker model referenced in this docu ment Index An alphabetized list of some topics included in this document Conventions Used in this Document The following icons are used throughout this document to call attention to important information pertaining to handling operation and maintenance of the server safety and preservation of the equipment and personal safety LS NOTE The note icon is followed by additional information to be consid ered A WARNING The warning icon is followed by information alerting you to a potential situation that may cause damage to property or equipment CAUTION The caution icon is followed by information warning you that a situation has the potential to cause bodily harm or death 8 amp 6 ProxYBLOCKER Quick START GUID
36. o to the System section of the con sole ProxyBlocker ai 8e6 ProxyBlocker a HOME SYSTEM GROUP LIBRARY REPORTING HELP QU Control Network Administrator SSYSTEM 5 T ge lee Diagnostics Alert Display Help Topics for the System section Patch Mode Authentication NIC Mode BackupRestore Reset SNMP Hardware Failure Detection X Strikes Blocking Warn Option Setting Customization ise a main topic fror ti 1 a topic or sub topic i fi lays in the right pane dow mouse over the 2 syrr indow or press F1 Press F5 to refresh the console For additional information beneath the Syste To navigate to anathe Home Group Library Reporting Host Name logo com IP 200 10 100 75 Version ProxyBlocker 1 0 00 4 Java Applet Window In this section of the console you will e Specify the device s the ProxyBlocker will use for listening to traffic and sending traffic e Configure LAN settings the ProxyBlocker will use on your network e Select NTP servers the ProxyBlocker will use for time synchronization with Internet clocks e Indicate the region in which the ProxyBlocker is geographically located LS NOTE After saving your entries in each of these windows Operation Mode LAN Settings NTP Servers Regional Setting you may be prompted to restart or reboot the server Click OK to acknowledge the contents of the alert box and then proceed to the next sub step without restarting or rebooting the
37. oceed to Step 3 If you cannot access the ProxyBlocker Administrator console please verify the status of the LAN connection in Windows on the network workstation and then try enabling dis abling the LAN connection If that fails to work check the following e The ProxyBlocker is turned on e The ProxyBlocker is connected to the same hub as your router firewall e Can the PC normally connect to the Internet e Is the PC able to ping LAN 1 of the ProxyBlocker e Is the ProxyBlocker plugged into a switch instead of a hub e Is there a caching server e Can the ProxyBlocker ping the filtered PC Refer to the System Command window in the Diagnostics section of the ProxyBlocker User Guide e Did you restart the ProxyBlocker after changing the network settings e Do you have both LAN ports connected to your network hub e If still unsuccessful contact an 8e6 Technologies solutions engineer or technical sup port representative 886 PRoxYBLOCKER Quick START GUIDE 37 8e6 Step 3 Test Filtering Once you have accessed the ProxyBlocker Administrator console you should test filter ing A Test the ProxyBlocker s filtering by opening a browser window on a network worksta tion and going to http test 8e6 net an empty site for testing pornography filtering B You should receive a block page If you do not contact an 8e6 Technologies solu tions engineer or technical support representative Ly NOTE Port 22 SSH must
38. on and select Properties B Click on Internet Protocol TCP IP to highlight it Windows NT and ME users should select the Protocols or Configuration tab and choose TCP IP Protocol C Click the Properties button A WARNING Be sure to make note of the current network settings on the setup workstation as you will need to return them for further setup procedures D Choose the option Use the following IP address Windows NT and ME users should choose the option Specify an IP Address E Type in the IP address of 1 2 3 1 F Type in the Subnet mask netmask of 255 0 0 0 and click OK G Close the LAN connection properties box 8E6 ProxYBLOCKER Quick START GUIDE 27 8e6 Link the Workstation to the ProxyBlocker The procedures outlined in this sub section require the use of the CAT 5E crossover cable A Plug one end of the CAT 5E crossover cable into the ProxyBlocker s LAN 2 port LS NOTE When facing the rear of the chassis the LAN 2 port is the port on the right JET TA g LAN1 LAN2 Portion of chassis rear B Plug the other end of the CAT 5E crossover cable into the setup workstation s net work card LS NOTE If a CAT 5E coupler was packaged with your unit this coupler can be used if the crossover cable is not long enough for your setup Plug one end of the CAT 5E crossover cable into the ProxyBlocker and the other end into the coupler Plug a standard CAT 5E cable into the o
39. oxyBlocker before connecting it to the network you must first shut down the server instead of restarting it To shut down the ProxyBlocker go to the navigation panel click Control and then select ShutDown Once the server is shut down you must power on the ProxyBlocker and then log back into the Administra tor console A Restart the server using the steps defined below i iii These steps must always be performed when restarting the ProxyBlocker Never reset the server by using the power or reset buttons i From the navigation panel of the System section of the console click Control and select Reboot from the pop up menu to display the Reboot window ii Click the Reboot button iii From the time you click Reboot you have approximately 2 minutes to perform sub steps B through E while the ProxyBlocker goes through the reboot process B Disconnect the crossover cable from the ProxyBlocker C Plug one end of a standard CAT 5E cable into the ProxyBlocker s LAN 1 port D Plug the other end of the CAT 5E cable into an open port on the network hub that handles the Internet traffic you wish to filter E Repeat sub steps B and C for the ProxyBlocker s LAN 2 port F Wait until the reboot process has completed indicated by the drive light staying off for 30 seconds This process may take 5 to 10 minutes Proceed to Step 2 L NOTES If you receive a connection failure message during the reboot process please disregard it
40. pattern proxypat ind ailed to download newslist Exception ue Feb 20 14 59 59 PST 2007 3074 Traveler has Finished running ue Feb 20 15 29 52 PST 2007 8153 Downloading full library update ue Feb 20 15 30 03 PST 2007 8153 Full library update has completed ue Feb 20 15 30 03 PST 2007 8153 Final update status Failed with the Following errors rror messages encountered ailed to login ailed to download impattern impat sind ailed to download ptoppattern ptoppat ind ailed to download proxypattern proxypat ind ailed to download newslist Exception I Host Name logo com IP 200 10 100 75 Frersion ProxyBlocker 1 0 00 4 Java Applet Window LS NOTE You will be notified in the log when the library has been completely updated by the message Full URL Library Update has completed If this message does not yet display click View Log again to view the latest information A WARNING At the conclusion of this step your ProxyBlocker will be actively filtering your network The ProxyBlocker is initially set to filter pornography sites on all of your network traffic associated with the hub to which it is connected 8E6 PROXxYBLOCKER Quick START GUIDE Se6 CONCLUSION Congratulations you have completed the ProxyBlocker quick start procedures Now that the ProxyBlocker is filtering your network the next step is to set up groups and create filtering profiles for group members
41. r the LAN2 IP address and subnet for LAN 2 the ProxyBlocker s second Ether net NIC The subnet selection is usually 255 255 0 0 16 bites or 255 255 255 0 24 bites but cannot be 255 255 255 255 32 bites D Enter the Primary IP address of the first DNS name server The ProxyBlocker uses this name server to resolve the domain name requested by users from the LAN 8E6 PRoxYBLOCKER Quick START GUIDE 33 8e6 34 E Enter the Secondary IP address of the second DNS name server The ProxyBlocker will use this name server to resolve the domain name requested by users from the LAN if the first DNS isn t working F Enter the Gateway IP address for the default router or firewall that is the main gate way for the entire network The ProxyBlocker will use this IP address to communicate outside the network A WARNING Be sure to take note of the LAN 1 and LAN 2 IP addresses and host name you assigned to the ProxyBlocker It is strongly suggested you document and store this information as it is now the only way of communi cating with the ProxyBlocker G Click Apply Network NTP Servers From the navigation panel click Network and choose NTP Servers from the pop up menu 8e6 ProxyBlocker HOME SYSTEM GROUP NTP Servers System gt Network gt NTP Servers Details Servers 128 59 35 142 142 310015 129 132 98 11 LIBRARY REPORTING HELP RE boe Administrator Diagnostics Alert Patch Mode Authenticat
42. ther end of the coupler and the free end of the standard CAT 5E cable into the setup workstation C Plug the ProxyBlocker into a power source with an appropriate rating A WARNING It is strongly suggested you use an uninterruptible power supply D Power on the ProxyBlocker by lowering the bezel and pressing the large button at the right of the front panel see diagram below JTN d amp amp B ae RESET Diagram of chassis front panel power button at far right The Boot Up Process The boot up process may take 5 10 minutes When the drive light remains off for 30 seconds the system is booted up See the LED Indicators and Buttons section for a description of Front LED Indicators and Buttons for Hardware Status Monitoring 28 8E6 PROXxYBLOCKER QUICK START GUIDE 8e6 If you wish to verify that the unit has been booted up you can perform the following test on your workstation Go to your taskbar and click Start gt Run In the dialog box type in cmd type in command if using Windows ME Click OK In the cmd exe window type in ping 1 2 3 4 Press Enter on your keyboard IAUN If you receive a reply the unit is up Network Setup When the ProxyBlocker is fully booted you can configure network settings For this step you will need your network administrator to provide you the host name gateway ad dress and two unused IP addresses Access the ProxyBlocker Administrator Console A Launch
43. ughout your session 8E6 PRoxYBLOCKER Quick START GUIDE 29 8e6 The Introductory Window displays minimized when the login dialog box of the Proxy Blocker Administrator console application opens see image on the next page Log in to ProxyBlocker Administrator Console In the login dialog box you need to enter the generic Username and Password ProxyBlocker miol x Please fill in the login information Username Password oc ce Java Applet Window A In the Username field type in admin B Inthe Password field type in user3 C Click OK to close the login dialog box and to go to the main screen of the Proxy Blocker Administrator console ProxyBlocker Eio x Be ProxyBiocker e OME SYSTEM GROUP LIBRARY REPORTING HE bP Q A ls fl Welcome Welcome to the ProxyBlocker management console This e ee screen displays product and system status information Beb Technologies Click the System Group Library or Reporting tab to access corresponding configuration properties Click Help For information on navigating the management console To return to this screen click the Home button Click Quit to exit the console 8e6 ProxyBlocker User Interface E Host Name logo com fir 200 10 100 75 Vrersion ProxyBlocker 1 0 00 4 Java Applet Window 30 8 E6 PROXxYBLOCKER Quick START GUIDE 8e6 Network Click the System button at the top of the screen to g
44. y update status Ly NOTE Modifications can be made at any time by returning to the specific screen of the wizard Log Off Disconnect the Peripherals A After completing the wizard setup procedures return to the System Configuration screen and press 9 to log out B Disconnect the peripherals from the ProxyBlocker 26 8 6 PRoxYBLockerR Quick START GUIDE Se6 Step 1B Console Setup Procedures Preliminary Setup Create a setup workstation using a Windows based laptop or desktop machine with a network card and Internet Explorer 5 5 or later The setup workstation will be used for accessing the ProxyBlocker server on the network and configuring the unit LS NOTE The Java Plug in version specified for the ProxyBlocker software ver sion must be installed on your workstation If your workstation does not have Java Runtime Environment you will be prompted to install it Workstation Configurations A From the desktop of the setup workstation follow the procedures for your machine type e Windows XP go to Start gt Control Panel Open Network Connections Right click the link for LAN or High Speed Internet and choose Properties e Windows 2000 right click the My Network Places icon and select Properties Right click the correct Local Area Connection and choose Properties e Windows NT right click the Network Neighborhood icon and select Properties e Windows ME right click the My Network Places ic

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - SoftBank SELECTION  SR-LUXi - Billiger.de  CSI-M701 取扱説明書(PDF形式、5.51MKバイト)  Air-Conditioners INDOOR UNIT PEA  Samsung PS-42C96HD Felhasználói kézikönyv  Operating instructions Diffuse reflection sensor with  取扱説明書 兼 無償修理規定  LG KG300 User's Manual  CS3100 CS3400 CS3400T  Model 2015—Feed Supervisor Application Program User`s Manual  