Home
Legrand 310855
Contents
1. ARCHIMOD HE Double conversion VFI three phase modular UPS 3 108 55 3 103 61 3 10473 Pack Cat Nos CONFIGURABLE CABINETS CONFIGURATIONS The cabinets are supplied empty and are preset for the power and capacity indicated in the table NOMINAL NUMBEROF NUMBEROF NO OF POWER NUMBER OF POWER kVA BATTERY CONTROL EXPANSION PHASES MODULES MODULES MODULES 3 104 58 20 12 1 1 1 3 3 3 1 1 3 310459 20 30 1 1 1 3 3 3 1 1 3 3 104 60 40 24 2 1 1 3 3 3 1 1 3 3 10461 60 18 3 3 3 3 10462 80 4 3 3 3 104 63 100 3 2 3 3 3 10464 120 3 3 3 3 Capacity of cabinet 18 U ADDITIONAL CABINETS FOR BATTERIES DESCRIPTION 3 108 18 Empty modular battery cabinet 3 108 21 Battery cabinet for 20 kVA UPS with 21x94 Ah long life batteries 3 108 22 Battery cabinet for 200 60 kVA UPS with 21x94 Ah long life batteries 3 108 23 Battery cabinet for 80 kVA UPS with 21x94 Ah long life batteries 3 108 24 Battery cabinet for 100 120 kVA UPS with 21x94 Ah long life batteries 3 108 65 Cover for empty battery slot 3 108 66 Cover for empty power module slot ACCESSORIES DESCRIPTION 3 108 73 6 7 kVA power module 3 108 76 kit of 3 x long life battery trays 3 108 64 Front rear door 3108 55 Kit of 3 x9 Ah battery trays 3 108 56 Kit of 3 empty battery trays 310851 Additional charger module 20 Power 20 kVA Backup time 65 min 1 Cabinet 1 Control module 3 Power modules 30 Battery modules 1 Distributi
2. on module 60 Power 60 kVA Backup time 8 min 1 Cabinet 3 Control modules 9 Power modules 18 Battery modules 1 Distribution module 100 Power 100 kVA Backup time 10 min 2 Cabinets 3 Control modules 2 Power expansion modules 15 Power modules 36 Battery modules 1 Distribution module 40 Power 40 kVA Backup time 21 min 1 Cabinet 2 Control modules 6 Power modules 24 Battery modules 1 Distribution module 80 Power 80 kVA Backup time 14 min 2 Cabinets 4 Control modules 12 Power modules 36 Battery modules 1 Distribution module 120 Power 120 kVA Backup time 8 min 2 Cabinets 3 Control modules 3 Power expansion modules 18 Power modules 36 Battery modules 1 Distribution module NOTE The backup times expressed in minutes are measured under optimum operating conditions New product codes In red codes for products that are normally available in stock in bold
Download Pdf Manuals
Related Search
Related Contents
T'nB FHPRO25 Porter-Cable 4114 Saw User Manual HP 15 15-f033wm Hampton Bay PG139HDS Instructions / Assembly Instruction Sheet iFace Series Installation Guide ShelterLogic 27776 Instructions / Assembly Maytag MGDZ400TQ2 User's Manual ISTRUZIONI PER L`USO Guía para secadoras - Lave-Rap Copyright © All rights reserved.
Failed to retrieve file