Home

Hewlett Packard Enterprise 5930 24-port Converged SFP+ / 2-port QSFP+ Module

image

Contents

1. 2013 From Version 2 to 3 Changed Switch Enclosure Options were revised and HP X140 40G QSFP LCLR4 SM XCVR was added to Configuration December 11 2013 From Version 1 to 2 Changed Updated the power specifications and accessories c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 23 QuickSpecs HP FlexFabric 5930 Switch Series Summary of Changes To learn more visit www hp com networking Copyright 2015 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 24
2. The system should not be operated with only one fan tray for more than 24 hours The system should not be operated without a fan tray for more than two minutes The system should not be operated outside of the temperature range of 32 F 0 C to 113 F 45 C Failure to comply with these operating requirements may void the product warranty Dimensions 17 32 w x 25 98 d x 1 72 h in 44 00 x 66 0 x 4 37 cm Weight 28 66 lb 13 kg shipping weight Full configuration weight 28 66 lb 13 kg 1 GB flash Packet buffer size 12 2 MB 4 GB SDRAM 10 Gbps Latency lt 1ps 64 byte packets Throughput up to 1429 Mpps Routing Switching capacity 2560 Gbps Routing table size 120000 entries IPv4 60000 entries IPv6 MAC address table size 288000 entries Operating temperature 32 F to 113 F 0 C to 45 C Operating relative humidity 10 to 95 noncondensing Acoustic Low speed fan 59 8 dB High speed fan 74 4 dB Frequency 50 60 Hz Maximum heat dissipation 597 1361 BTU hr 629 83 1435 86 kJ hr Voltage 90 264 VAC rated 40 to 75 VDC rated depending on power supply chosen Maximum power rating 399 W Idle power 175W Notes Idle power is the actual power consumption of the device with no ports connected Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules
3. HP X130 10G SFP LC LRM Transceiver JD093B HP X130 10G SFP LC LR Transceiver JD094B HP X240 10G SFP to SFP 0 65m Direct Attach Copper Cable JD095C HP X240 10G SFP to SFP 1 2m Direct Attach Copper Cable JDO96C HP X240 10G SFP to SFP 3m Direct Attach Copper Cable JDO97C HP X120 1G SFP LCLH100 Transceiver JD103A HP X130 10G XFP LC ZR Single Mode 80km 1550nm Transceiver JD107A HP X130 10G XFP LC LR Single Mode 10km 1310nm Transceiver JD108B HP X120 1G SFP LC SX Transceiver JD118B HP X120 1G SFP LC LX Transceiver JD119B HP X240 10G SFP to SFP 5m Direct Attach Copper Cable JGO81C HP X130 10G SFP LC ER 40km Transceiver JG234A HP X130 10G SFP LC ER 40km Transceiver JG234A HP X130 10G SFP LC LH 80km Transceiver JG915A HP X240 40G QSFP QSFP 1m Direct Attach Copper Cable JG326A Power Supply HP A58x0AF 650W AC Power Supply JC680A HP 58x0AF 650W DC Power Supply JC681A HP FlexFabric 5930 32QSFP Switch_PL JG726A HP X711 Front port side to Back power side Airflow High Volume Fan Tray JG552A HP X712 Back power side to Front port side Airflow High Volume Fan Tray JG553A HP FlexFabric 5930 4Slot Switch JH179A HP 5930 24 port SFP and 2 port QSFP Module JH180A HP 5930 24 port SFP and 2 port QSFP with MACsec Module JH181A HP 5930 24 port 10GBase T and 2 port QSFP with MACsec Module JH182A HP 5930 8 port QSFP Module JH183A HP 5930 24 port Converged Port and 2 port QSFP Module JH184A Ap c04111326 DA 14818 Worldwide Vers
4. SFP 5m DAC Cable Box Level Integration CTO Models CTO Solution Sku HP 59xx CTO Switch Solution e SSP trigger sku CTO Switch Chassis HP FF 5930 32QSFP Switch e 32 QSFP ports min 0 max 32 e Must select min 1 Power Supply Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 JG726A See Configuration Note 1 JH178A See Configuration Note 1 JH179A JG505A JG726A See Configuration Note 1 5 Page 7 Q u i C kS p ecs HP FlexFabric 5930 Switch Series Configuration Must select min 2 Fan Tray e 1U Height HP FF 5930 2Slot 2QSFP Switch JH178A e 2 QSFP ports min 0 max 2 See Configuration e 2 port expansion module slots Note 1 5 e Must select min 1 Power Supply e Must select min 2 Fan Trays e 1U Height HP FF 5930 4Slot Switch JH179A e 4port expansion module slots See Configuration e Must select min 1 Power Supply Note 5 e Must select min 2 Fan Trays e 2U Height Configuration Rules Note 1 Note 5 The following 40G Transceivers install into this switch Use 0D1 or B01 quoted to switch if switch is CTO if applicable JG661A HP X140 40G QSFP LC LR4 SM XCVR JG325B HP X140 40G QSFP MPO SR4 XCVR JG709A HP X140 40G QSFP CSR4 300m XCVR JG326A HP X240 40G QSFP QSFP 1m DAC Cable JG327A HP X240 40G QSFP QSFP 3m DAC Cable JG328A HP X240 40G QSFP QSFP 5m DAC Cable JG329A HP X240 QSFP 4x10G SFP 1m DAC Cable JG330A HP X240 QSFP 4x10G SFP 3m DAC C
5. Shld Kit JH189A B01 e Supported on JH187A See Configuration Note 1 HP FF 5930 4Slot Opcty Shld Kit JH190A B01 e Supported on JH188A See Configuration Note 1 Configuration Rules Note 1 If selected with a CTO Switch Solution Quantity 1 of JG585A B01 must also be ordered Tamper Evidence Labels System std 0 max 1 User Selection min 0 max 1 HP 12mm x 60mm Tmpr Evidence 30 Lbl JG585A B01 e Supported on JG727A JH187A JH188A See Configuration Note 1 Configuration Rules Note 1 If selected with a CTO Switch Solution Quantity 1 of JHO62A B01 JH189A BO1 or JH190A B01 must also be ordered Remarks Each JHO62A JH189A or JH190A would use 1 of JG585A Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 14 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications HP FlexFabric 5930 32QSFP Switch JG726A 1 0 ports and slots Additional ports and slots Power supplies Fan tray Physical characteristics Memory and processor Performance Environment Electrical characteristics Safety Emissions Immunity O 32 QSFP 40GbE ports 1 RJ 45 serial console port 1 RJ 45 out of band management port 1 USB 2 0 2 power supply slots 1 minimum power supply required ordered separately 2 fan tray slots The customer must order fan trays as fan trays are not included with the switch This system requires two same direction airflow fan trays to function properly
6. and recovery Layer 3 routing Virtual Router Redundancy Protocol VRRP and VRRP Extended allow quick failover of router ports Policy based routing makes routing decisions based on policies set by the network administrator Equal Cost Multipath ECMP enables multiple equal cost links in a routing environment to increase link redundancy and scale bandwidth Layer 3 IPv4 routing provides routing of IPv4 at media speed supports static routes RIP and RIPv2 OSPF BGP and IS IS Open shortest path first OSPF delivers faster convergence uses this link state routing Interior Gateway Protocol IGP which supports ECMP NSSA and MD5 authentication for increased security and graceful restart for faster failure recovery Border Gateway Protocol 4 BGP 4 delivers an implementation of the Exterior Gateway Protocol EGP utilizing path vectors uses TCP for enhanced reliability for the route discovery process reduces bandwidth consumption by advertising only incremental updates supports extensive policies for increased flexibility scales to very large networks Intermediate system to intermediate system IS IS uses a path vector Interior Gateway Protocol IGP which is defined by the ISO organization for IS IS routing and extended by IETF RFC 1195 to operate in both TCP IP and the OSI reference model Integrated IS IS Static IPv6 routing provides simple manually configured IPv6 routing Dual IP stack maintains separate stacks for IPv4 a
7. populated UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN CSA C22 2 No 60950 1 Anatel ULAR GOST EN 60950 1 A11 FDA 21 CFR Subchapter J NOM ROHS Compliance VCCI Class A EN 55022 Class A ICES 003 Class A ANSI C63 4 2003 AS NZS CISPR 22 Class A EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EMC Directive 2004 108 EC FCC CFR 47 Part 15 Class A Generic ETSI EN 300 386 V1 3 3 EN EN 55024 1998 A1 2001 A2 2003 c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 15 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications ESD EN 61000 4 2 IEC 61000 4 2 Radiated EN 61000 4 3 IEC 61000 4 3 EFT Burst EN 61000 4 4 IEC 61000 4 4 Surge EN 61000 4 5 IEC 61000 4 5 Conducted EN 61000 4 6 IEC 61000 4 6 Power frequency magnetic IEC 61000 4 8 EN 61000 4 8 field Voltage dips and EN 61000 4 11 IEC 61000 4 11 interruptions Harmonics EN 61000 3 2 IEC 61000 3 2 Flicker EN 61000 3 3 IEC 61000 3 3 Management IMC Intelligent Management Center command line interface out of band management SNMP Manager Telnet FTP Notes The customer must order a power supply as the device does not come with one At least one JC680A or JC681A is required Services Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in y
8. that is ideal for the data center Spanning Tree Protocol STP supports STP IEEE 802 1D Rapid STP RSTP IEEE 802 1w and Multiple STP MSTP IEEE 802 1s VLAN support provides support for 4 096 VLANs based on port MAC address IPv4 subnet protocol and guest VLAN supports VLAN mapping IGMP support provides support for IGMP Snooping Fast Leave and Group Policy IPv6 IGMP Snooping provides Layer 2 optimization of multicast traffic c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 3 QuickSpecs HP FlexFabric 5930 Switch Series Overview DHCP support at Layer 2 provides full DHCP Snooping support for DHCP Snooping Option 82 DHCP Relay Option 82 DHCP Snooping Trust and DHCP Snooping Item Backup Layer 3 services Address Resolution Protocol ARP determines the MAC address of another IP host in the same subnet supports static ARPs gratuitous ARP allows detection of duplicate IP addresses proxy ARP allows normal ARP operation between subnets or when subnets are separated by a Layer 2 network Dynamic Host Configuration Protocol DHCP simplifies the management of large IP networks and supports client and server DHCP Relay enables DHCP operation across subnets Operations administration and maintenance OAM support provides support for Connectivity Fault Management IEEE 802 1AG and Ethernet in the First Mile IEEE 802 3AH provides additional monitoring that can be used for fast fault detection
9. to 4 x LC 15m Cable K2Q47A HP Premier Flex MPO MPO OM4 8f 10m Cbl QK729A HP Premier Flex MPO MPO OM4 12f 50m Cbl QK731A HP Premier Flex MPO MPO OM4 12f 100m Cbl H6Z30A Internal Power Supplies JG726A JH178A JG727A JH187A System std 0 max 2 User Selection min 1 max 2 per switch JH179A JH188A System std 0 max 4 User Selection min 1 max 4 per switch HP 58x0AF 650W AC Power Supply JC680A e includes 1 x c13 300w See Configuration Note 1 2 PDU Cable NA MX TW JP JC680A B2B e C15 PDU Jumper Cord NA MX TW JP PDU Cable ROW JC680A B2C e 15 PDU Jumper Cord ROW HP 58x0AF 650W DC Power Supply JC681A See Configuration Note 1 Configuration Rules Note 1 If 2 power supplies are selected they must be the same Sku number Note 2 Localization Wall Power Cord required on orders without B2B B2C PDU Power Cord See Localization Menu REMARK When Switches Routers are Factory Racked Then B2B or B2C should be the Defaulted Power Cable option on the Switches Routers Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 12 Q u i C kSp ecs HP FlexFabric 5930 Switch Series Configuration Remarks Drop down under power supply should offer the following options and results Switch Router to PDU Power Cord B2B in NA Mexico Taiwan and Japan or B2C ROW Watson Default B2B or B2C for Rack Level CTO Switch Router Power Supply to Wall Power Cord Localized Option Watson Defaul
10. 0G QSFP QSFP 3m DAC Cable HP X240 40G QSFP QSFP 5m DAC Cable HP X240 QSFP 4x10G SFP 1m DAC Cable HP X240 QSFP 4x10G SFP 3m DAC Cable HP X240 QSFP 4x10G SFP 5m DAC Cable Cables AOC Cables HP BLc 40G QSFP QSFP 7m AOC Cable HP BLc 40G QSFP QSFP 15m AOC Cable HP BLc 40G QSFP QSFP 10m AOC Cable Multi Mode Cables Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 HP FlexFabric 5930 Switch Series JDO61A JDO62A JD063B JDO89B JDO98B JDO99B JD118B JD119B JD092B JD093B JD094B JG234A JD095C B01 JDOS6C BO1 JDO097C B01 JGO81C B01 JC784C B01 H6Z42A JC908A AJ718A AW584A JG661A JG325B JG709A JG326A B01 JG327A BO1 JG328A B01 JG329A B01 JG330A B01 JG331A B01 720205 B21 720211 B21 720208 B21 Page 11 QuickSpecs HP FlexFabric 5930 Switch Series Configuration HP 5m Multi mode OM3 LC LC FC Cable AJ833A HP 1m Multi mode OM3 LC LC FC Cable AJ834A HP 2 m Multimode OM3 LC LC FC Cable AJ835A HP 5 m Multimode OM3 LC LC FC Cable AJ836A HP 15 m Multimode OM3 LC LC FC Cable AJ837A HP 30 m Multimode OM3 LC LC FC Cable AJ838A HP 50 m Multimode OM3 LC LC FC Cable AJ839A HP Premier Flex LC LC OM4 2f 1m Cbl QK732A HP Premier Flex LC LC OM4 2f 2m Cbl QK733A HP Premier Flex LC LC OM4 2f 5m Cbl QK734A HP Premier Flex LC LC OM4 2f 15m Cbl QK735A HP Premier Flex LC LC OM4 2f 30m Cbl QK736A HP Premier Flex LC LC OM4 2f 50m Cbl QK737A MPO Cables HP MPO to 4 x LC 5m Cable K2Q46A HP MPO
11. 240 QSFP 4x10G SFP 3m DAC Cable JG331A HP X240 QSFP 4x10G SFP 5m DAC Cable Note 11 If HP CTO Switch Chassis is selected for Rack Level Integration Then the Switch needs to integrate with 0D1 to the Rack Enter the following menu selections as integrated to the CTO Model X server above if order is factory built Modules JH178A JH187A System std 0 max 2 User Selection min 0 max 2 JH179A JH188A System std 0 max 4 User Selection min 0 max 4 HP 5930 24p SFP and 2p QSFP Mod JH180A e 24SFP ports min 0 max 24 See Configuration e 2QSFP ports min 0 max 2 Note 1 2 HP 5930 24p SFP and 2p QSFP Mod w Msec JH181A e 24SFP ports min 0 max 24 See Configuration e 2 QSFP ports min 0 max 2 Note 1 2 HP 5930 24p 10GBase T and 2p QSFP Mod JH182A e 241 10GBase T ports See Configuration e 2 QSFP ports min 0 max 2 Note 2 HP 5930 8 port QSFP Module JH183A e 8 QSFP ports min 0 max 8 See Configuration Note 2 HP 5930 24p Conv Port and 2p QSFP Mod JH184A e 24 Converged SFP FC ports min 0 max 24 See Configuration e 2QSFP ports min 0 max 2 Note 1 2 3 4 Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 9 Q u i C kS p ecs HP FlexFabric 5930 Switch Series Configuration Configuration Rules Note 1 The following Transceivers install into this Module s SFP Ports Use 0D1 or B01 if switch is CTO if applicable JD092B HP X130 10G SFP LC SR
12. EN 61000 4 5 IEC 61000 4 5 Conducted EN 61000 4 6 IEC 61000 4 6 Power frequency magnetic IEC 61000 4 8 EN 61000 4 8 field Voltage dips and EN 61000 4 11 IEC 61000 4 11 interruptions Harmonics EN 61000 3 2 IEC 61000 3 2 Flicker EN 61000 3 3 IEC 61000 3 3 Management IMC Intelligent Management Center command line interface out of band management SNMP Manager Telnet FTP Services Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office HP FlexFabric 5930 2Slot 2QSFP Switch JH178A 1 0 ports and slots 2 module slots 2 QSFP 40GbE ports Additional ports and slots 1 RJ 45 serial console port 1 RJ 45 out of band management port 1 USB 2 0 Power supplies 2 power supply slots 1 minimum power supply required ordered separately Fan tray 2 fan tray slots The customer must order fan trays as fan trays are not included with the switch This system requires Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 17 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications Physical characteristics Memory and processor Performance Reliability Environment Electrical characteristics Safety Emissions Immunity two same direction airflow fan trays to function properly The system should not be operated with onl
13. FC SFP 1 Pack AW584A HP 8Gb LW 10km FC SFP 1 Pk Transceiver Note 4 The following FC Transceivers install into this Module s SFP FC Ports and are a 4 Pack Bundle min 0 max 6 JC908A HP 16G FC 10G Eth SFP 4 XCVR Bndl Remarks Watson When JH184A module is selected default 1 of the JC908A transceiver bundles Transceivers SFP Transceivers Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 10 QuickSpecs Configuration HP X125 1G SFP LCLH40 1310nm Transceiver HP X120 1G SFP LCLH40 1550nm Transceiver HP X125 1G SFP LC LH70 Transceiver HP X120 1G SFP RJ45 T Transceiver HP X120 1G SFP LC BX 10 U Transceiver HP X120 1G SFP LC BX 10 D Transceiver HP X125 1G SFP LC SX Transceiver HP X120 1G SFP LC LX Transceiver SFP Transceivers HP X130 10G SFP LC SR Transceiver HP X130 10G SFP LC LRM Transceiver HP X130 10G SFP LC LR Transceiver HP X130 10G SFP LC ER 40km Transceiver HP X240 10G SFP SFP 0 65m DAC Cable HP X240 10G SFP SFP 1 2m DAC Cable HP X240 10G SFP SFP 3m DAC Cable HP X240 10G SFP SFP 5m DAC Cable HP X240 10G SFP 7m DAC Cable FC SFP Transceivers HP 16Gb FC 10GbE 100m SFP XCVR HP 16G FC 10G Eth SFP 4 XCVR Bndl HP 8Gb Short Wave FC SFP 1 Pack HP 8Gb LW 10km FC SFP 1 Pk Transceiver QSFP Transceivers HP X140 40G QSFP LC LR4 SM XCVR HP X140 40G QSFP MPO SR4 XCVR HP X140 40G QSFP CSR4 300m XCVR HP X240 40G QSFP QSFP 1m DAC Cable HP X240 4
14. Pv6 Neighbor Discovery RFC 2462 IPv6 Stateless Address Auto configuration RFC 2463 ICMPv6 RFC 2464 Transmission of IPv6 over Ethernet Networks RFC 2473 Generic Packet Tunneling in IPv6 RFC 2545 Use of MP BGP 4 for IPv6 RFC 2563 ICMPv6 RFC 2711 IPv6 Router Alert Option RFC 2740 OSPFv3 for IPv6 RFC 2767 Dual stacks IPv46 amp IPv6 RFC 3315 DHCPv6 client and relay RFC 4291 IP Version 6 Addressing Architecture RFC 4862 IPv6 Stateless Address Auto configuration RFC 5095 Deprecation of Type 0 Routing Headers in IPv6 MIBs RFC 1213 MIB II RFC 1907 SNMPv2 MIB RFC 2571 SNMP Framework MIB RFC 2572 SNMP MPD MIB RFC 2573 SNMP Notification MIB RFC 2573 SNMP Target MIB RFC 2574 SNMP USM MIB RFC 2737 Entity MIB Version 2 RFC 3414 SNMP User based SM MIB RFC 3415 SNMP View based ACM MIB LLDP EXT DOT1 MIB LLDP EXT DOT3 MIB LLDP MIB Network management RFC 3164 BSD syslog Protocol OSPF RFC 1587 OSPF NSSA RFC 2328 OSPFv2 Page 19 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications RFC 826 ARP RFC 854 TELNET RFC 856 TELNET RFC 868 Time Protocol RFC 896 Congestion Control in IP TCP Internetworks RFC 950 Internet Standard Subnetting Procedure RFC 1027 Proxy ARP RFC 1058 RIPv1 RFC 1091 Telnet Terminal Type Option RFC 1141 Incremental updating of the Internet checksum RFC 1142 OSI IS IS Intra domain Routing Protocol RFC 1191 Path MTU discovery RFC 1213 Management Information Bas
15. QuickSpecs HP FlexFabric 5930 Switch Series Overview HP FlexFabric 5930 Switch Series Models HP FlexFabric 5930 32QSFP Switch JG726A HP FlexFabric 5930 4Slot Switch JH179A HP FlexFabric 5930 2Slot 2QSFP Switch JH178A Key features Cut through with ultra low latency and wire speed VXLAN VTEP support for virtualized environments High denisty 10GbE and 40GbE spine ToR connectivity IPv6 support with full L2 and L3 features Convergence ready with DCB FCoE and TRILL Product overview The HP FlexFabric 5930 Switch Series is a family of high density ultra low latency top of rack ToR switches that is part of the HP FlexNetwork architecture s HP FlexFabric solution Ideally suited for deployment at the aggregation or server access layer of large enterprise data centers the HP 5930 Switch Series is also powerful enough for deployment at the core layer of medium sized enterprises With the increase in virtualized applications and server to server traffic customers now require spine and ToR switch innovations that will meet their needs for higher performance server connectivity convergence of Ethernet and storage traffic the capability to handle virtual environments and ultra low latency all in a single device the HP FlexFabric 5930 Switch Series Features and benefits Quality of Service QoS e Powerful QoS features o Flexible queue scheduling including Strict Priority SP WRR WORR WFQ SP WRR SP WDRR SP WFQ Configurabl
16. Transceiver JD093B HP X130 10G SFP LC LRM Transceiver JDO94B HP X130 10G SFP LC LR Transceiver JG234A HP X130 10G SFP LC ER 40km Transceiver JDO95C HP X240 10G SFP SFP 0 65m DAC Cable JDO96C HP X240 10G SFP SFP 1 2m DAC Cable JDO97C HP X240 10G SFP SFP 3m DAC Cable JGO81C HP X240 10G SFP SFP 5m DAC Cable JC784C HP X240 10G SFP 7m DAC Cable JDO61A HP X125 1G SFP LCLH40 1310nm Transceiver JD062A HP X120 1G SFP LCLH40 1550nm Transceiver JD063B HP X125 1G SFP LCLH70 Transceiver JDO89B HP X120 1G SFP RJ45 T Transceiver JDO98B HP X120 1G SFP LC BX 10 U Transceiver JDO99B HP X120 1G SFP LC BX 10 D Transceiver JD118B HP X125 1G SFP LC SX Transceiver JD119B HP X120 1G SFP LC LX Transceiver Note 2 The following 40G Transceivers install into this Module s QSFP Ports Use 0D1 or B01 if switch is CTO if applicable JG661A HP X140 40G QSFP LC LR4 SM XCVR JG325B HP X140 40G QSFP MPO SR4 XCVR JG709A HP X140 40G QSFP CSR4 300m XCVR JG326A HP X240 40G QSFP QSFP 1m DAC Cable JG327A HP X240 40G QSFP QSFP 3m DAC Cable JG328A HP X240 40G QSFP QSFP 5m DAC Cable JG329A HP X240 QSFP 4x10G SFP 1m DAC Cable JG330A HP X240 QSFP 4x10G SFP 3m DAC Cable JG331A HP X240 QSFP 4x10G SFP 5m DAC Cable Note 3 The following FC Transceivers install into this Module s SFP FC Ports Use 0D1 or BTO if switch is CTO if applicable H6Z42A HP 16Gb FC 10GbE 100m SFP XCVR AJ718A HP 8Gb Short Wave
17. able JG331A HP X240 QSFP 4x10G SFP 5m DAC Cable If the Switch Chassis is to be Box Level Factory Integrated CTO Then the 0D1 is required on the Switch Chassis and integrated to the JG505A HP 59xx CTO Switch Solution Min 1 Max 1 Router per SSP Rack Level Integration CTO Models CTO Switch Chassis HP FF 5930 32QSFP Switch JG726A e 32 QSFP ports min 0 max 32 See Configuration e Must select min 1 Power Supply Note 1 11 e Must select min 2 Fan Tray e 1U Height HP FF 5930 2Slot 2QSFP Switch JH178A 2 QSFP ports min 0 max 2 See Configuration 2 port expansion module slots Note 1 11 Must select min 1 Power Supply Must select min 2 Fan Trays 1U Height c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 8 Q u i C kSp ecs HP FlexFabric 5930 Switch Series Configuration HP FF 5930 4Slot Switch JH179A e 4 port expansion module slots See Configuration e Must select min 1 Power Supply Note 11 e Must select min 2 Fan Trays e 2U Height Configuration Rules Note 1 The following 40G Transceivers install into this Switch Use 0D1 or B01 if switch is CTO if applicable JG661A HP X140 40G QSFP LCLR4 SM XCVR JG325B HP X140 40G QSFP MPO SR4 XCVR JG709A HP X140 40G QSFP CSR4 300m XCVR JG326A HP X240 40G QSFP QSFP 1m DAC Cable JG327A HP X240 40G QSFP QSFP 3m DAC Cable JG328A HP X240 40G QSFP QSFP 5m DAC Cable JG329A HP X240 QSFP 4x10G SFP 1m DAC Cable JG330A HP X
18. ating system Comware v7 software s modular design and multiple processes bring native high stability independent process monitoring and restart the OS also allows individual software modules to be upgraded for higher availability and supports enhanced serviceability functions like hitless software upgrades with single chassis ISSU TRILL SPB and EVB VEPA TRansparent Interconnection of Lots of Links TRILL is supported including support of TRILL with IRF TRILL ECMP up to 8 paths Support for Shortest Path Bridging IEEE 802 1aq with ECMP up to 8 paths Edge Virtual Bridging with Virtual Ethernet Port Aggregator EVB VEPA provides connectivity into the virtual environment for a data center ready environment Reversible airflow enhanced for data center hot cold aisle deployment with reversible airflow for either front to back or back to front airflow Redundant fans and power supplies Internal redundant and hot pluggable power supplies and dual fan trays enhance reliability and availability Lower OPEX and greener data center provide reversible airflow and advanced chassis power management Data Center Bridging DCB protocols provides support for IEEE 802 1Qbb Priority Flow Control PFC Data Center Bridging Exchange DCBX IEEE 802 1Qaz Enhanced Transmission Selection ETS Explicit Congestion Notification ECN for converged FCoE iSCSI and RoCE environments FCoE support provides support T11 standards compliant FC BB 5 Fibre Channel
19. ation remote visibility is provided with sFlow and SNMP v1 v2 v3 and is fully supported in HP Intelligent Management Center IMC ISSU and hot patching c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 2 QuickSpecs HP FlexFabric 5930 Switch Series Overview provides hitless software upgrades with single unit In Services Software Upgrade ISSU and hitless patching of the modular operating system Autoconfiguration provides automatic configuration via DHCP autoconfiguration NTP SNTP and PTP Support synchronize timekeeping among distributed time servers and clients Support for Network Time Protocol NTP Secure Network Time Protocol SNTP and Precision Time Protocol PTP IEEE 1588v2 2008 Resiliency and high availability HP Intelligent Resilient Framework IRF technology enables an HP FlexFabric to deliver resilient scalable and secured data center networks for physical and virtualized environments groups up to nine HP 5930 switches in an IRF configuration allowing them to be configured and managed as a Single switch with a single IP address simplifies ToR deployment and management reducing data center deployment and operating expenses IEEE 802 1w Rapid Convergence Spanning Tree Protocol increases network uptime through faster recovery from failed links IEEE 802 1s Multiple Spanning Tree provides high link availability in multiple VLAN environments by allowing multiple spanning trees Virtual Rou
20. ces in silicon development shuts off unused ports and utilizes variable speed fans reducing energy costs Management e USB support o File copy allows users to copy switch files to and from a USB flash drive e Multiple configuration files stores easily to the flash image e SNMPv1 v2c and v3 facilitate centralized discovery monitoring and secure management of networking devices e Qut of band interface isolates management traffic from user data plane traffic for complete isolation and total reachability no matter what happens in the data plane e Port mirroring enables traffic on a port to be simultaneously sent to a network analyzer for monitoring e Remote configuration and management is available through a command line interface CLI e IEEE 802 1AB Link Layer Discovery Protocol LLDP advertises and receives management information from adjacent devices on a network facilitating easy mapping by network management applications e sFlow RFC 3176 provides scalable ASIC based wirespeed network monitoring and accounting with no impact on network performance this allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and real time network monitoring purposes e Command authorization leverages RADIUS to link a custom list of CLI commands to an individual network administrator s login an audit trail documents activity e Dual flash images provides independent primary and secondary op
21. criptions and product numbers For details about services and response times in your area please contact your local HP sales office BGP RFC 1163 Border Gateway Protocol BGP RFC 1771 BGPv4 RFC 1997 BGP Communities Attribute RFC 2918 Route Refresh Capability RFC 3392 Capabilities Advertisement with BGP 4 RFC 4271 A Border Gateway Protocol 4 BGP 4 RFC 4360 BGP Extended Communities Attribute RFC 4456 BGP Route Reflection An Alternative to Full Mesh Internal BGP IBGP RFC 4760 Multiprotocol Extensions for BGP 4 Device management RFC 1157 SNMPv1 v2c RFC 1305 NTPv3 RFC 1591 DNS client RFC 1902 SNMPv2 RFC 1908 SNMP v1 2 Coexistence RFC 2573 SNMPv3 Applications RFC 2576 Coexistence between SNMP V1 V2 V3 Multiple Configuration Files Multiple Software Images SSHv1 SSHv2 Secure Shell TACACS TACACS General protocols IEEE 802 1D MAC Bridges IEEE 802 1p Priority IEEE 802 1Q VLANs IEEE 802 1s Multiple Spanning Trees IEEE 802 1w Rapid Reconfiguration of Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 3ae 10 Gigabit Ethernet IEEE 802 3ag Ethernet OAM IEEE 802 3ah Ethernet in First Mile over Point to Point Fiber EFMF IEEE 802 3x Flow Control RFC 768 UDP RFC 783 TFTP Protocol revision 2 RFC 791 IP RFC 792 ICMP RFC 793 TCP c04111326 DA 14818 Worldwide Version 9 April 24 2015 IPv6 RFC 2080 RIPng for IPv6 RFC 2460 IPv6 Specification RFC 2461 I
22. d UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN CSA C22 2 No 60950 1 Anatel ULAR GOST EN 60950 1 A11 FDA 21 CFR Subchapter J NOM ROHS Compliance VCCI Class A EN 55022 Class A ICES 003 Class A ANSI C63 4 2003 AS NZS CISPR 22 Class A EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EMC Directive 2004 108 EC FCC CFR 47 Part 15 Class A Generic ETSI EN 300 386 V1 3 3 EN EN 55024 1998 A1 2001 A2 2003 ESD EN 61000 4 2 IEC 61000 4 2 Radiated EN 61000 4 3 IEC 61000 4 3 EFT Burst EN 61000 4 4 IEC 61000 4 4 Surge EN 61000 4 5 IEC 61000 4 5 Conducted EN 61000 4 6 IEC 61000 4 6 Power frequency magnetic IEC 61000 4 8 EN 61000 4 8 field Voltage dips and EN 61000 4 11 IEC 61000 4 11 c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 18 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications Management Notes Services Standards and protocols applies to all products in series interruptions Harmonics EN 61000 3 2 IEC 61000 3 2 Flicker EN 61000 3 3 IEC 61000 3 3 IMC Intelligent Management Center command line interface out of band management SNMP Manager Telnet FTP The customer must order a power supply as the device does not come with one At least one JC680A or JC681A is required Refer to the HP website at www hp com networking services for details on the service level des
23. e Buffer Time range Queue Shaping CAR with 8kbps granularity o Packet filtering and remarking packet filtering at L2 Layer 2 through L4 Layer 4 flow classification based on source MAC address destination MAC address source IP IPv4 IPv6 address destination IP IPv4 IPv6 address port protocol and VLAN Data center optimized e Flexible high port density the HP FlexFabric 5930 Switch Series enables scaling of the server edge with 10GbE and 40GbE spine and ToR deployments to new heights with a high density 32 port fixed port switch in a 1RU design a 2 Slot Modular design with Two 40GbE QSFP ports and a 4 Slot Design Support for 1OGbE SFP 10GBASE T Converged Port 1 10GbE or 4 8Gbps Fiber Channel and 40GbE ports e High performance switching cut through and nonblocking architecture delivers low latency 1 microsecond for 10GbE for very demanding enterprise applications the switch delivers high performance switching capacity and wire speed packet forwarding e Higher scalability HP Intelligent Resilient Framework IRF technology simplifies the architecture of server access networks up to nine HP 5930 switches can be combined to deliver unmatched scalability of virtualized access layer switches and flatter two tier networks using IRF which reduces cost and complexity Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 1 QuickSpecs HP FlexFabric 5930 Switch Series Overview Advanced modular oper
24. e for Network Management of TCP IP based internets RFC 1253 OSPF v2 RFC 1531 Dynamic Host Configuration Protocol RFC 1533 DHCP Options and BOOTP Vendor Extensions RFC 1534 DHCP BOOTP Interoperation RFC 1541 DHCP RFC 1591 DNS client only RFC 1624 Incremental Internet Checksum RFC 1723 RIP v2 RFC 1812 IPv4 Routing RFC 2030 Simple Network Time Protocol SNTP v4 RFC 2131 DHCP RFC 2236 IGMP Snooping RFC 2338 VRRP RFC 2453 RIPv2 RFC 2581 TCP Congestion Control RFC 2644 Directed Broadcast Control RFC 2767 Dual Stacks IPv4 amp IPv6 RFC 3046 DHCP Relay Agent Information Option RFC 3768 Virtual Router Redundancy Protocol VRRP RFC 4250 The Secure Shell SSH Protocol Assigned Numbers RFC 4251 The Secure Shell SSH Protocol Architecture RFC 4252 The Secure Shell SSH Authentication Protocol RFC 4253 The Secure Shell SSH Transport Layer Protocol RFC 4254 The Secure Shell SSH Connection Protocol RFC 4364 BGP MPLS IP Virtual Private Networks VPNs RFC 4419 Diffie Hellman Group Exchange for the Secure Shell SSH Transport Layer Protocol RFC 4594 Configuration Guidelines for DiffServ Service Classes RFC 4941 Privacy Extensions for Stateless Address Autoconfiguration in IPv6 RFC 3101 OSPF NSSA RFC 3137 OSPF Stub Router Advertisement RFC 3623 Graceful OSPF Restart RFC 4577 OSPF as the Provider Customer Edge Protocol for BGP MPLS IP Virtual Private Networks VPNs RFC 4811 OSPF Out of Band LSDB Resynch
25. elative humidity 10 to 90 noncondensing Acoustic Low speed fan 59 8 dB High speed fan 74 4 dB Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 16 QuickSpecs HP FlexFabric 5930 Switch Series Technical Specifications Electrical characteristics Frequency 50 60 Hz Maximum heat dissipation 474 3030 BTU hr 500 07 3196 65 kJ hr Voltage 90 264 VAC rated 40 to 75 VDC rated depending on power supply chosen Maximum power rating 888 W Idle power 139 W Notes Idle power is the actual power consumption of the device with no ports connected Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules populated Safety UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN CSA C22 2 No 60950 1 Anatel ULAR GOST EN 60950 1 A11 FDA 21 CFR Subchapter J NOM ROHS Compliance Emissions VCCI Class A EN 55022 Class A ICES 003 Class A ANSI C63 4 2003 AS NZS CISPR 22 Class A EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EMC Directive 2004 108 EC FCC CFR 47 Part 15 Class A Immunity Generic ETSI EN 300 386 V1 3 3 EN EN 55024 1998 A1 2001 A2 2003 ESD EN 61000 4 2 IEC 61000 4 2 Radiated EN 61000 4 3 IEC 61000 4 3 EFT Burst EN 61000 4 4 IEC 61000 4 4 Surge
26. ement Center IMC centrally configures updates monitors and troubleshoots e Remote intelligent mirroring mirrors ingress egress ACL selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the network Security e Access control lists ACLs provide IP Layer 3 filtering based on source destination IP address subnet and source destination TCP UDP port number e RADIUS TACACS eases switch management security administration by using a password authentication server e Secure shell encrypts all transmitted data for secure remote CLI access over IP networks e IEEE 802 1X and RADIUS network logins controls port based access for authentication and accountability e Port security allows access only to specified MAC addresses which can be learned or specified by the administrator Convergence e LLDP MED Media Endpoint Discovery defines a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones Warranty and support e 1 year warranty advance hardware replacement with 10 calendar day delivery available in most countries e Electronic and telephone support limited electronic and business hours telephone support is available from HP for the entire warranty period to reach our support centers refer to www hp com networking contact support for details on the duration of support provided with your product purchase refer to www hp c
27. erating system files for backup while upgrading e Command line interface CLI provides a secure easy to use CLI for configuring the module via SSH or a switch console provides direct real time session isibility e Logging provides local and remote logging of events via SNMP v2c and v3 and syslog provides log throttling and log filtering to reduce the number of log events generated e Management interface control provides management access through a modem port and terminal interface as well as in band and out of band Ethernet ports provides access through terminal interface Telnet or secure shell SSH Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 5 QuickSpecs HP FlexFabric 5930 Switch Series Overview e Industry standard CLI with a hierarchical structure reduces training time and expenses and increases productivity in multivendor installations e Management security restricts access to critical configuration commands offers multiple privilege levels with password protection ACLs provide Telnet and SNMP access local and remote syslog capabilities allow logging of all access e Information center provides a central repository for system and network information aggregates all logs traps and debugging information generated by the system and maintains them in order of severity outputs the network information to multiple channels based on user defined rules e Network management HP Intelligent Manag
28. ion 9 April 24 2015 Page 21 QuickSpecs HP FlexFabric 5930 Switch Series Accessories HP 5930 4Slot Back Power Side to Front Port Side Airflow Fan Tray JH185A HP 5930 4Slot Front Port Side to Back Power Side Airflow Fan Tray JH186A HP FlexFabric 5930 2Slot 2QSFP Switch JH178A HP 5930 24 port SFP and 2 port QSFP Module JH180A HP 5930 24 port SFP and 2 port QSFP with MACsec Module JH181A HP 5930 24 port 10GBase T and 2 port QSFP with MACsec Module JH182A HP 5930 8 port QSFP Module JH183A HP 5930 24 port Converged Port and 2 port QSFP Module JH184A HP X711 Front port side to Back power side Airflow High Volume Fan Tray JG552A HP X712 Back power side to Front port side Airflow High Volume Fan Tray JG553A Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 22 QuickSpecs HP FlexFabric 5930 Switch Series Summary of Changes Date Version History Action Description of Change April 24 2015 From Version 8 to 9 Added Added two new models e JH179A e JH178A Changed Updated Overview Configuration Technical Specifications and Accessories sections December 12 2014 From Version 7 to 8 Removed Deleted SKU JG325A July 3 2014 From Version 6 to 7 Changed Configuration menu updated April 15 2014 From Version 4 to 5 Changed Transceivers were revised March 19 2013 From Version 3 to 4 Changed Transceivers were revised in Configuration December 17
29. nd IPv6 to ease the transition from an IPv4 only network to an IPv6 only network design Routing Information Protocol next generation RIPng extends RIPv2 to support IPv6 addressing OSPFv3 provides OSPF support for IPv6 BGP extends BGP 4 to support Multiprotocol BGP MBGP including support for IPv6 addressing IS IS for IPv6 extends IS IS to support IPv6 addressing IPv6 tunneling allows IPv6 packets to traverse IPv4 only networks by encapsulating the IPv6 packet into a standard IPv4 packet supports manually configured 6to4 and Intra Site Automatic Tunnel Addressing Protocol ISATAP tunnels is an important element for the transition from IPv4 to IPv6 c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 4 QuickSpecs HP FlexFabric 5930 Switch Series Overview e Policy routing allows custom filters for increased performance and security supports ACLs IP prefix AS paths community lists and aggregate policies e Bidirectional Forwarding Detection BFD enables link connectivity monitoring and reduces network convergence time for RIP OSPF BGP IS IS VRRP MPLS and IRF e Multicast Routing PIM Dense and Sparse modes provides robust support of multicast protocols e Layer 3 IPv6 routing provides routing of IPv6 at media speed supports static routing RIPng OSPFv3 BGP4 for IPv6 and IS ISv6 Additional information e Green IT and power improves energy efficiency through the use of the latest advan
30. om networking warrantysummary e Software releases to find software for your product refer to www hp com networking support for details on the software releases available with your product purchase refer to www hp com networking warranty Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 6 Q u i C kSp ecs HP FlexFabric 5930 Switch Series Configuration Build To Order BTO is a standalone unit with no integration BTO products ship standalone are not part of a CTO or Rack Shippable solution Standard Switch Enclosures HP FF 5930 32QSFP Switch e 32 QSFP ports min 0 max 32 e Must select min 1 Power Supply e Must select min 2 Fan Trays e 1U Height HP FF 5930 2Slot 2QSFP Switch 2 QSFP ports min 0 max 2 2 port expansion module slots Must select min 1 Power Supply Must select min 2 Fan Trays 1U Height HP FF 5930 4Slot Switch 4 port expansion module slots Must select min 1 Power Supply Must select min 2 Fan Trays 2U Height Configuration Rules Note 1 The following 40G Transceivers install into this switch JG661A HP X140 40G QSFP LCLR4 SM XCVR JG325B HP X140 40G QSFP MPO SR4 XCVR JG709A HP X140 40G QSFP CSR4 300m XCVR JG326A HP X240 40G QSFP QSFP 1m DAC Cable JG327A HP X240 40G QSFP QSFP 3m DAC Cable JG328A HP X240 40G QSFP QSFP 5m DAC Cable JG329A HP X240 QSFP 4x10G SFP 1m DAC Cable JG330A HP X240 QSFP 4x10G SFP 3m DAC Cable JG331A HP X240 QSFP 4x10G
31. our area please contact your local HP sales office HP FlexFabric 5930 4Slot Switch JH179A 1 0 ports and slots 4 module slots Additional ports and slots 1 RJ 45 serial console port 1 RJ 45 out of band management port 1 USB 2 0 Power supplies 4 power supply slots 2 minimum power supplies required ordered separately Fan tray 2 fan tray slots The customer must order fan trays as fan trays are not included with the switch This system requires two same direction airflow fan trays to function properly The system should not be operated with only one fan tray for more than 24 hours The system should not be operated without a fan tray for more than two minutes The system should not be operated outside of the temperature range of 32 F 0 C to 113 F 45 C Failure to comply with these operating requirements may void the product warranty Physical characteristics Dimensions 17 32 w x 25 98 d x 3 47 h in 44 00 x 66 0 x 8 81 cm 2U height Weight 66 14 lb 30 kg shipping weight Full configuration weight 59 52 b 27 kg Memory and processor 1 GB flash Packet buffer size 12 2 MB 4 GB SDRAM Performance 10 Gbps Latency lt 1 us 64 byte packets Throughput up to 1429 Mpps Routing Switching capacity 2560 Gbps Routing table size 120000 entries IPv4 60000 entries IPv6 MAC address table size 288000 entries Reliability MTBF years 35 8 MTTR hours 1 Environment Operating temperature 32 F to 113 F 0 C to 45 C Operating r
32. over Ethernet FCoE including FCoE Initialization Protocol FIP FCP Fiber Channel enhanced port types VE TE and VF NPV NPIV Fabric Name Server RSCN Login Services and name server zoning Per VSAN Fabric Services FSPF Standard Zoning and Fiber Channel Ping Jumbo frames with frame sizes of up to 10 000 bytes on Gigabit Ethernet and 10 Gigabit ports allows high performance remote backup and disaster recovery services to be enabled VXLAN Support VXLAN Layer 2 Gateway support for up to 4k tunnels Manageability Full featured console provides complete control of the switch with a familiar CLI Troubleshooting o Ingress and egress port monitoring enable network problem solving o Traceroute and ping enable testing of network connectivity Multiple configuration files allow multiple configuration files to be stored to a flash image sFlow RFC 3176 provides wire speed traffic accounting and monitoring SNMP v1 v2c and v3 facilitate centralized discovery monitoring and secure management of networking devices Out of band interface isolates management traffic from user data plane traffic for complete isolation and total reachability no matter what happens in the data plane Remote configuration and management delivered through a secure command line interface CLI over Telnet and SSH Role Based Access Control RBAC provides multiple levels of access Configuration Rollback and multiple configurations on the flash provide ease of oper
33. ronization RFC 4812 OSPF Restart Signaling RFC 4813 OSPF Link Local Signaling QoS Cos IEEE 802 1p CoS RFC 2475 DiffServ Architecture RFC 2597 DiffServ Assured Forwarding AF RFC 3247 Supplemental Information for the New Definition of the EF PHB Expedited Forwarding Per Hop Behavior RFC 3260 New Terminology and Clarifications for DiffServ Security Access Control Lists ACLs SSHv2 Secure Shell c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 20 QuickSpecs HP FlexFabric 5930 Switch Series Accessories HP FlexFabric 5930 Switch Series accessories Transceivers HP X240 40G QSFP QSFP 3m Direct Attach Copper Cable JG327A HP X240 40G QSFP QSFP 5m Direct Attach Copper Cable JG328A HP X240 40G QSFP to 4x10G SFP 1m Direct Attach Copper Splitter Cable JG329A HP X240 40G QSFP to 4x10G SFP 3m Direct Attach Copper Splitter Cable JG330A HP X240 40G QSFP to 4x10G SFP 5m Direct Attach Copper Splitter Cable JG331A HP X140 40G QSFP LC LR4 SM 10km 1310nm Transceiver JG661A HP X140 40G QSFP MPO SR4 Transceiver JG325B HP X140 40G QSFP MPO MM 850nm CSR4 300m Transceiver JG709A HP X240 10G SFP SFP 7m Direct Attach Copper Cable JC784C HP X140 40G CFP LC LR4 10km SM Transceiver JC857A HP X125 1G SFP LCLH40 1310nm Transceiver JDO61A HP X120 1G SFP LC LH40 1550nm Transceiver JDO62A HP X125 1G SFP LCLH70 Transceiver JD063B HP X120 1G SFP RJ45 T Transceiver JD089B HP X130 10G SFP LC SR Transceiver JD092B
34. t for BTO and Box Level CTO Switch Options Fan Trays System std 0 max 2 User Selection min 2 max 2 per switch HP X711 Frt prt Bck pwr HV Fan Tray JG552A See Configuration Note 1 2 HP X712 Bck pwr Frt prt HV Fan Tray JG553A See Configuration Note 1 2 HP 5930 4SlIt Back to Front Fan Tray JH185A See Configuration Note 1 3 HP 5930 4Slt Front to Back Fan Tray JH186A See Configuration Note 1 3 Configuration Rules Note 1 Fan Trays cannot be mixed in the same switch enclosure Note 2 This power supply is only supported on JG726A JH178A JG727A and JH187A Note 3 This power supply is only supported on JH179A and JH188A Remarks Watson Blue Text If there is any empty space below the switch in a rack when using Back to Front Fan Trays JG553A the rack will receive an Air Plenum kit that takes up 1U of additional space in the rack The Air Plenum kit is not required on fully configured racks This only applies for CTO Rack Level Integration The Air Plenum Kit is a non saleable SKU and is brought in automatically for CTO Factory Rack Level Integration Opacity Shield Kit System std 0 max 1 User Selection min 0 max 1 Ap c04111326 DA 14818 Worldwide Version 9 April 24 2015 Page 13 Q u i C kSp ecs HP FlexFabric 5930 Switch Series Configuration HP FF 5930 32QSFP Opcty Shld Kit JHO62A B01 e Supported on JG727A See Configuration Note 1 HP FF 5930 2Slot 2QSFP Opcty
35. ter Redundancy Protocol VRRP allows groups of two routers to dynamically back each other up to create highly available routed environments Hitless patch upgrades allows patches and new service features to be installed without restarting the equipment increasing network uptime and facilitating maintenance Ultrafast protocol convergence lt 50 ms with standard based failure detection Bidirectional Forwarding Detection BFD enables link connectivity monitoring and reduces network convergence time for RIP OSPF BGP IS IS VRRP MPLS and IRF Device Link Detection Protocol DLDP monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected preventing loops in STP based networks Graceful restart allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown and significantly reduces convergence times upon recovery supports OSPF BGP and IS IS Layer 2 switching MAC based VLAN provides granular control and security uses RADIUS to map a MAC address user to specific VLANs Address Resolution Protocol ARP supports static dynamic and reverse ARP and ARP proxy IEEE 802 3x Flow Control provides intelligent congestion management via PAUSE frames Ethernet Link Aggregation provides IEEE 802 3ad Link Aggregation of up to 128 groups of 32 ports support for LACP LACP Local Forwarding First and LACP Short time provides a fast resilient environment
36. y one fan tray for more than 24 hours The system should not be operated without a fan tray for more than two minutes The system should not be operated outside of the temperature range of 32 F 0 C to 113 F 45 C Failure to comply with these operating requirements may void the product warranty Dimensions 17 32 w x 25 98 d x 1 74 h in 44 00 x 66 0 x 4 42 cm Weight 1U height Full configuration weight 39 68 lb 18 kg shipping weight 1 GB flash Packet buffer size 12 2 MB 4 GB SDRAM 10 Gbps Latency lt 1 us 64 byte packets Throughput up to 1071 Mpps Routing Switching capacity 1440 Gbps Routing table size 120000 entries IPv4 60000 entries IPv6 MAC address table size 288000 entries MTBF years 47 2 MTTR hours 1 Operating temperature 32 F to 113 F 0 C to 45 C Operating relative humidity 10 to 90 noncondensing Acoustic Low speed fan 59 8 dB High speed fan 74 4 dB Frequency 50 60 Hz Maximum heat dissipation 358 1733 BTU hr 377 69 1828 31 kJ hr Voltage 90 264 VAC rated 40 to 75 VDC rated depending on power supply chosen Maximum power rating 508 W Idle power 105 W Notes Idle power is the actual power consumption of the device with no ports connected Maximum power rating and maximum heat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules populate

Download Pdf Manuals